The Walker Group Architecture, Inc PO Box 541, New Bern, NC 28563
252.636.8778 (PHONE)
252.636.8992 (FAX)
WALKER
GROUP
i n c o r p o r a t e d the
ARCHITECTURE
DISCLOSURE OF INFORMATION
CONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR
(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE
(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL
SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.
(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION
TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
FIRE ALARM AND MASS NOTIFICATION LEGEND
FIRE ALARM MANUAL PULL STATION, 48" AFF TO ACTUATING ARM, UON
FIRE ALARM/MNS AUDIO/VISUAL (SPEAKER/STROBE) APPLIANCE, CEILING
MOUNTED. SUBSCRIPT INDICATES MINIMUM CANDELA RATING OF
STROBE. TAP SPEAKERS ACCORDINGLY FOR THE SPACE THEY SERVE.
F
S FIRE ALARM SYSTEM PHOTOELECTRIC SMOKE DETECTOR, CEILING MOUNTED
REQ'D REQUIRED
PNL PANEL
NATIONAL ELECTRICAL CODENEC
GROUNDGND
EXIST EXISTING
EXISTING TO REMAINETR
CONDUIT C
UNLESS OTHERWISE NOTEDUON
FIRE ALARM/ MASS NOTIFICATION SYSTEM
AREA OF REFUGE ASSISTANCEARA
ABBREVIATIONS
ABOVE FINISHED GRADEAFG
ABOVE FINISHED FLOORAFF
FAMN
BELOW FINISHED GRADEBFG
FIRE ALARM/MASS NOTIFICATION
CONTROL PANEL
FIRE ALARM AUDIO (SPEAKER) APPLIANCE, 80" AFG, WALL MOUNT,
SUBSCRIPT "WP" INDICATES WEATHER PROOF.
MASS NOTIFICATION SYSTEMMNS
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL
GENERAL FIRE ALARM NOTESFIRE ALARM DEMOLITION NOTES
GENERAL: DEMOLITION DRAWINGS ARE BASED ON EXISTING PLANS AND
FIELD INVESTIGATION PRIOR TO DEMOLITION. VISIT THE EXISTING
BUILDING PRIOR TO BID IN ORDER TO BECOME FAMILIAR WITH THE
EXISTING CONDITIONS AND IN ORDER TO AVOID CONFLICTS. THE
CONTRACTOR MUST PROTECT AND PRESERVE ALL EXISTING WORK NOT
PART OF PROJECT.
DASHED ITEMS: ITEMS SHOWN DASHED ON DEMOLITION PLANS ARE
EXISTING AND MUST BE REMOVED.
SOLID ITEMS: ITEMS SHOWN SOLID ON DEMOLITION PLANS ARE EXISTING
TO REMAIN.
EXISTING CONDUIT: EXISTING CABLING MUST BE REPLACED. EXISTING
CONDUITS THAT WILL NOT BE REUSED MUST BE REMOVED WHERE THEY
WILL BE EXPOSED UPON COMPLETION OF NEW WORK. EXISTING CONDUIT
TO REMAIN CONCEALED IN WALLS MUST BE ABANDONED. EXISTING
CONDUIT TO REMAIN BELOW FLOOR SLAB MUST BE CUT OFF ONE INCH
BELOW ROUGH FLOOR AND GROUTED FLUSH. REMOVE WIRING FROM
CONDUIT THAT IS ABANDONED.
REPAIR DAMAGE: EXERCISE CARE IN REMOVAL OF DEMOLITION ITEMS.
REPAIR, AT NO ADDITIONAL COST TO THE OWNER, ANY DAMAGE CAUSED
TO EXISTING CONSTRUCTION AND/OR EQUIPMENT TO REMAIN.
DEMOLISHED MATERIALS: MATERIALS REMOVED UNDER DEMOLITION,
NOT TO BE RELOCATED OR DESIGNATED TO BE TURNED OVER TO THE
OWNER, WILL BECOME THE PROPERTY OF THE CONTRACTOR AND MUST
BE REMOVED COMPLETELY FROM THE SITE.
SCHEDULE OUTAGES: SCHEDULED OUTAGES MUST BE COORDINATED
THROUGH THE GOVERNMENT CONSTRUCTION MANAGER OR
CONTRACTING OFFICER.
NOTIFICATION: NOTIFY THE GOVERNMENT CONSTRUCTION MANAGER OR
CONTRACTING OFFICE PRIOR TO TURNING OFF CIRCUITS.
GENERAL: UNLESS SPECIFICALLY INDICATED OTHERWISE, WORK
SHOWN ON FIRE ALARM DRAWINGS IS NEW WORK TO INCLUDE THE FIRE
ALARM/MASS NOTIFICATION PANEL, DEVICES, AND APPLIANCES ON
DRAWINGS FOR A COMPLETE AND OPERATIONAL SYSTEM.
COORDINATION: THE CONTRACTOR MUST REVIEW CONTRACT
DOCUMENTS INCLUDING FIRE ALARM DRAWINGS AND SPECIFICATIONS.
CONTRACTOR MUST COORDINATE AND ADJUST ACCORDINGLY AS
DIRECTED BY THE COTR.
AS-BUILT DRAWINGS: SECURE AN EXTRA SET OF DRAWINGS TO BE
KEPT ON SITE AND MARK DAILY, THE DRAWINGS IN RED AS THE
PROJECT PROGRESSES IN ORDER TO KEEP AN ACCURATE RECORD OF
ALL DEVIATIONS BETWEEN THE WORK SHOWN ON THE DRAWINGS AND
THE WORK WHICH IS ACTUALLY INSTALLED. THESE MARKED DRAWINGS
MUST REFLECT ANY AND ALL CHANGES AND REVISIONS TO THE
ORIGINAL DESIGN WHICH EXISTS IN THE COMPLETED WORK. DELIVER
THE MARKED DRAWINGS TO THE COTR AT PROJECT CLOSE-OUT. IN
ADDITION, PROVIDE CONTACT ID POINT DESCRIPTIONS FOR EACH
DEVICE.
INSPECTIONS: ARRANGE NECESSARY INSPECTIONS. DELIVER
REQUIRED INSPECTION CERTIFICATES TO THE GOVERNMENT.
LABELING: ALL CONDUIT, JUNCTION/BACKBOXES, COVERS AND
COUPLINGS, WHEN PROVIDED, MUST BE FACTORY PAINTED RED IN
UNFINISHED AREAS (E.G. ABOVE CEILINGS, MECHANICAL ROOMS, ETC.).
ALL CONDUIT, JUNCTION/BACKBOXES, COVERS AND COUPLINGS, WHEN
PROVIDED, ARE PERMITTED TO BE PAINTED TO MATCH THE ROOM
FINISHING IN FINISHED AREAS. THE INSIDE COVER OR THE JUNCTION
BOX MUST BE IDENTIFIED AS "FIRE ALARM" AND THE CONDUIT MUST
HAVE PAINTED RED BANDS 3/4" WIDE AT 20' INTERVALS ON BOTH SIDES
OF ALL FLOOR, WALL, AND CEILING PENTRATIONS. LABEL ALL JUNCTION
BOXES WITH CIRCUIT DESIGNATIONS OF THE CABLING INSIDE. PROVIDE
LEGIBLE TYPED LABEL ON ALL ADDRESSABLE DEVICES TO INDICATE ITS
ADDRESS. FOR ANY DEVICE LOCATED ABOVE ACCESSIBLE CEILING,
ATTACH A LEGIBLE TYPED LABEL TO THE CEILING GRID INDICATING THE
DEVICE NOMENCLATURE AND ADDRESS.
WORKING CLEARANCE: COORDINATE FINAL LOCATIONS OF FIRE ALARM
EQUIPMENT WITH MECHANICAL DUCTWORK, PIPING ETC. AND ASSURE
WORKING CLEARANCE WILL BE MET. SUFFICIENT ACCESS AND
WORKING SPACE MUST BE PROVIDED AND MAINTAINED AROUND FIRE
ALARM EQUIPMENT AS REQUIRED BY THE NATIONAL ELECTRICAL CODE.
CONTRACTOR MUST COORDINATE FINAL LOCATION OF EQUIPMENT
PROVIDED.
LOCAL OPERATING CONSOLELOC
MOUNTING HEIGHTS: MOUNTING HEIGHTS INDICATED ARE FROM THE
FINISHED FLOOR TO THE CENTERLINE OF THE DEVICE UNLESS
OTHERWISE NOTED.
FIRE STOPPING: FOR WALL OR FLOOR PENETRATIONS THROUGH
FIRE-RATED STRUCTURES PROVIDE FIRE-STOPPING TO SEAL THE
PENETRATIONS AFTER THE CONDUIT HAS BEEN INSTALLED. FIRE
STOPPING FOR PENETRATIONS MUST BE UL APPROVED PER THE
PENETRATION MADE IN ORDER TO MAINTAIN FIRE-RATED INTEGRITY OF
THE STRUCTURE.
FIRE ALARM COORDINATION: THE ELECTRICAL CONTRACTOR MUST
COORDINATE WITH THE FIRE ALARM SYSTEM PROVIDER AND PROVIDE
POWER CONNECTIONS TO COMPONENTS WHETHER SHOWN OR NOT.
MANUFACTURERS REQUIRE VARYING QUANTITIES OF POWER
CONNECTIONS FOR EQUIPMENT LIKE EXPANDER PANELS AND POWER
SUPPLIES. THESE DEVICES ARE DEPENDENT UPON THE SPECIFIC
MANUFACTURERS SYSTEM. THE FIRE ALARM SYSTEM SUPPLIER MUST
NOTIFY THE OTHER APPROPRIATE SUB-CONTRACTORS ABOUT THESE
REQUIREMENTS AND CONNECTION MUST BE PROVIDED AS PART OF
THE PROJECT.
FIRE ALARM EQUIPMENT SURVIVAL: A SMOKE DETECTOR IS REQUIRED
AT ALL CONTROL PANEL LOCATIONS (I.E. FIRE ALARM PANEL,
NOTIFICATION EXTENDER PANELS, TRANSMITTERS, ETC.).
CONTRACTOR MUST PROVIDE SYSTEM SMOKE DETECTORS FOR ALL
LOCATIONS OF FIRE ALARM PANELS, TO INCLUDE THOSE SHOWN AND
THOSE THAT ARE ADDED BY THE CONTRACTOR FOR THEIR SPECIFIC
DESIGN.
CONDUIT: ALL ADDED FIRE ALARM/MASS NOTIFICATION SYSTEM WIRING
MUST BE INSTALLED IN CONDUIT (EMT MINIMUM). EXISTING EMT MAY BE
REUSED WHERE IT SATISFIES REQUIREMENTS OF NFPA 70.
CONDUIT SEALS: PROVIDE CONDUIT SEAL IN ACCORDANCE WITH NFPA
70 300.7 TO RACEWAYS EXPOSED TO DIFFERENT TEMPERATURES.
CONDUCTORS: ALL CONDUCTORS MUST BE REPLACED WITH NEW.
INTELLIGIBILITY LEVEL: CONTRACTOR MUST VERIFY INTELLIGIBILITY
LEVEL BY MEASUREMENT AFTER INSTALLATION OF 0.7 CIS FOR NAVY
AND MARINE CORP PROJECTS. COMMERCIALLY AVAILABLE TEST
INSTRUMENTATION MUST BE USED TO MEASURE INTELLIGIBILITY AS
SPECIFIED BY IEC 60849 AND IEC 60268-16. THE MEAN VALUE OF AT
LEAST THREE READINGS MUST BE USED TO COMPUTE THE
INTELLIGIBILITY SCORE AT EACH TEST LOCATION.
3/4" CONDUIT
W/ PULL STRING
EXISTING
EXTERNAL
ANTENNA
25' MAXIMUM
DEDICATED 120V, 20A CIRCUIT
FROM SAME SOURCE THAT
FEEDS FAMN.
F S
TO OTHER
ADDRESSABLE
DEVICES
TO OTHER
ADDRESSABLE
DEVICES
1. THE FIRE ALARM AND DETECTION SYSTEM IS TO
BE FULLY COMPLIANT WITH THE CURRENT
EDITIONS OF UFC 3-600-01, UFC 3-600-10N, UFC
4-021-01, AND NFPA 72 FOR A FIRE ALARM AND AN
EMERGENCY VOICE ALARM COMMUNICATION
SYSTEM. THE SYSTEM IS DESIGNED TO INTERFACE
WITH THE SITE MNS.
2. THE FAMN SHALL BE CAPABLE OF ACCEPTING 10
VOLTS ROOT MEAN SQUARED (VRMS), 25 VRMS,
70.7 VRMS AND/OR LINE LEVEL (.707 VRMS) AUDIO
INPUTS.
3. FAMN SHALL BE CONFIGURED TO ACCEPT DRY
CONTACT INPUT FROM AN EXTERNAL INTERFACE
TO ALERT THE FIRE ALARM PANEL THAT A MNS
MESSAGE IS FORTHCOMING. THE FIRE ALARM
PANEL SHALL BE CONFIGURED SO THAT WHILE
THIS INPUT IS ACTIVE (CONTACT CLOSED) THE
FIRE ALARM PANEL SHALL ROUTE AUDIO
PROVIDED BY THE MNS INTERFACE DIRECTLY TO
ALL CONNECTED FIRE ALARM SPEAKERS. THE
SYSTEM SHALL BE PROGRAMMED SO THIS
EXTERNAL AUDIO INPUT WILL RECEIVE HIGHEST
PRIORITY AND OVERRIDE ALL FIRE ALARM
NOTIFICATION SO LONG AS THE INPUT IS ACTIVE.
WHEN THE INPUT GOES INACTIVE (CONTACT
OPEN) THE EXTERNAL AUDIO ROUTING WILL
CEASE AND THE FIRE ALARM PANEL SHALL
AUTOMATICALLY RETURN TO THE PRIOR
NOTIFICATION PROGRAM THAT WAS ACTIVE
BEFORE THE MNS MESSAGE.
4. FAMN SHALL BE COMPATIBLE AND OPERABLE
WITH THE EXISTING FIRE ALARM SUPERVISING
STATION SHUREGUARD II. EXISTING BASEWIDE
MASS NOTIFICATION REPORTING SYSTEM IS A
COOPER INDUSTRIES WAVES SYSTEM.
CONTRACTOR SHALL PROVIDE ALL EQUIPMENT
AND LABOR REQUIRED TO CONNECT THE NEW
FIRE ALARM AND DETECTION SYSTEM TO THE
BASE'S SUPERVISING STATION. WAVES SYSTEM
TRANSCEIVER TO BE PROVIDED BY THE
GOVERNMENT.
5. DACT SHALL BE CONFIGURED TO TRANSMIT
SIGNALS IN CONTACT ID FORMAT.
6. SIGNALS TRANSMITTED OVER THE PRIMARY AND
SECONDARY MEANS OF TRANSMISSION SHALL BE
POINT SPECIFIC WITH EACH ADDRESS AND
CONDITION INDICATED AT THE FIRE ALARM PANEL
TRANSMITTED SEPARATELY. ALL FIRE ALARMS,
SUPERVISORY ALARMS, AND TROUBLE
CONDITIONS SHALL BE TRANSMITTED TO THE
SUPERVISING STATION. CONNECTION TO THE
FIRE ALARM REPORTING SYSTEM AND
PROGRAMMING OF THE DACT MODULE AND HEAD
END EQUIPMENT SHUREGUARD II SHALL BE
COORDINATED WITH THE FIRE ALARM REPORTING
SYSTEM (FARS) ADMINISTRATOR.
7. PROVIDE A LAMINATED GRAPHIC FLOOR PLAN
ADJACENT TO THE FAMN DEPICTING ALL FIRE
ALARM DEVICES AND EQUIPMENT WITHIN THE
FACILITY.
8. FIRE ALARM PLANS INDICATE AREA OF STROBE
COVERAGE AND ARE DIAGRAMMATIC ONLY.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING
ADDITIONAL SPEAKERS FOR EACH FACILITY TO
MEET ALL MASS NOTIFICATION SYSTEM
INTELLIGIBILITY REQUIREMENTS IN ACCORDANCE
WITH UFC 4-021-01.
9. LABEL ALL DEVICES WITH THEIR ADDRESSES.
FIRE ALARM AND MNS MONITORING NOTES
FAMN
(BLDG 16)
A C
TU
A
TE
C
O M
M O
N A
LA
R
M S
IG
N
A L
A C
TU
A
TE
A
U D
IB
LE
A
LA
R M
S
IG
N A
L
A C
TU
A
TE
C
O M
M O
N S
U P
E R
V
IS
O R
Y S
IG
N
A L
IN
D
IC
A
TO
R
A C
TU
A
TE
A
U D
IB
LE
S U
P E
R V
IS
O
R Y
S
IG
N A
L
A C
TU
A
TE
C
O M
M O
N T
R O
U B
LE
S
IG
N
A L
IN
D
IC
A
TO
R
A C
TU
A
TE
A
U D
IB
LE
C O
M M
O N
T R
O U
B
LE
S
IG
N A
L
A C
TI
V
A
TE
D
IS
P
LA
Y O
N F
A C
P A
N D
A N
N U
N C
IA
TO
R S
A C
TU
A
TE
A
U D
IB
LE
E V
A C
U A
TI
O
N S
IG
N
A
LS
V
O
IC
E M
E S
S A
G E
A C
TI
V
A
TE
V
IS
U A
L E
V A
C U
A
TI
O N
S
IG
N A
LS
TR
A
N S
M
IT
F
IR
E A
LA
R
M S
IG
N
A L
TO
S
U P
E R
V
IS
IN
G
S
TA
TI
O
N
S H
U T
D O
W N
A S
S O
C
IA
TE
D
A H
U
O V
E R
R
ID
E O
TH
E
R M
E S
S A
G E
S
A C
TI
V
A
TE
A U
D
IB
LE
A
N D
V
IS
U A
L S
IG
N
A
LS
CONTROL UNIT ANNUNCIATION NOTIFICATION SUPP.
SYSTEM INPUTS BELOW A B C D E F G H I J K L M
1 MANUAL FIRE ALARM BOXES X X X X X X 1
2 SMOKE DETECTORS X X X X X X 2
3 3
4 4
5 5
FIRE ALARM AC POWER FAILURE X X X
FIRE ALARM SYSTEM LOW BATTERY X X X
OPEN CIRCUIT X X X
GROUND FAULT X X X
NOTIFICATION APPLIANCE CIRCUIT SHORT X X X
A B C D E F G H I J K L M
SYSTEM OUTPUT BELOW
LOCAL OPERATING CONSOLE (LOC) X
DUCT SMOKE DETECTORS X X X X X X X
TR
A
N S
M
IT
T R
O U
B
LE
S
IG
N A
L
TO
S U
P E
R V
IS
IN
G S
TA
TI
O N
X
X
X
X
X
TRX-401
TRANSCEIVER
FINISHED
WALL
WALL MOUNTED
SMOKE DETECTOR
HEAT DETECTORS
NEVER HERE
CEILING MOUNTED
SMOKE/HEAT DETECTOR
ACCEPTED HERE
4" 12"
MAX
CEILING
3' MINIMUM
A/C SUPPLY OR
RETURN
DIFFUSER
MAGNETIC
DOOR
HOLDER 5"
DOOR
WIDTH
LESS 3"
MANUAL
PULL
STATION
TO EXIT
DOOR 5'
MAXIMUM
42"MIN TO 48"
MAX TO TOP OF
PULL HANDLE
92" MIN AFF
AUDIBLE
ONLYAUDIBLE/VISUAL
& VISUAL ONLY
APPLIANCES
SYNCHRONIZE
MORE THAN TWO
APPLIANCES IN
ANY FIELD OF
VIEW.
F I R EF I R E
FOR CEILING HEIGHTS LESS THAN 86"
THE VISUAL LENS MOUNTING HEIGHT
SHALL BE WITHIN 6" OF THE CEILING
96"
MAXIMUM
AFF
80"
MINIMUM
AFF
FINISHED FLOOR
NOTE: MEASUREMENTS
SHOWN ARE TO THE CLOSEST
EDGE OF THE DETECTOR
6" MINIMUM BFC
D A
C T
(2) CAT6 UTP TO TELEPHONE PATCH PANEL
FINAL TERMINATIONS BY GOVERNMENT
PATCH PANEL
PRIMARY + BACKUP
(2) CAT6 UTP
(GREEN)
D
TO AHU
SHUTDOWN
FIRE ALARM/MASS NOTIFICATION INPUT-OUTPUT MATRIX
SCALE: NO SCALEA
FIRE ALARM SYSTEM DEVICE MOUNTING HEIGHT DETAIL
SCALE: NO SCALEB
FIRE ALARM/MASS NOTIFICATION SYSTEM RISER DIAGRAM
SCALE: NO SCALEC 4/30/20
S
WP
S
WP
NETWORK
TELEPHONE
F S
TO OTHER
ADDRESSABLE
DEVICES
TO OTHER
ADDRESSABLE
DEVICES
FAMN
(BLDG 16A)
D A
C T
S
WP
S
WP
(2) CAT6 UTP TO TELEPHONE PATCH PANEL
FINAL TERMINATIONS BY GOVERNMENT
PATCH PANEL
PRIMARY + BACKUP
NETWORK
TELEPHONE
3/4" CONDUIT
W/ PULL STRING
25' MAXIMUM
TRX-401
TRANSCEIVER
EXTERNAL
ANTENNA
5'
M A
X
IM
U M
C A
B
LE
L E
N G
TH
2"C FOR INTERCONNECTION
( CABLING PER MANUFACTURERS
RECOMMENDATIONS)
S
S
FIRE ALARM AUDIO/VISUAL (HORN/STROBE) APPLIANCEF
FIRE ALARM VISUAL (STROBE) APPLIANCEF
(2) CAT6 UTP
(GREEN)
1 REVISION 1 6/6/2020
| Sheets and Views |
| FA001 GENERAL NOTES, LEGEND AND ABBREVIATIONS |
File details come from the government source that posted it. Updated .