60025840.pdf

PDF 309 KB Posted

Attached to
Renovation & Addition to Protestant Chapel, 16 & 16A
Solicitation number
N6247020R6012
Issued by

View the file

Other files

File Type Posted
Amnd 0007 20R6012 FINAL.pdf PDF
08 62 00 Translucent Wall Panels.pdf PDF
60025844.pdf PDF
Amnd 0006 20R6012 FINAL.pdf PDF
60025843.pdf PDF
Protestant Chapel Revision 02 Combined Drawings 071020.pdf PDF
60025763A.pdf PDF
Amnd 0005 20R6012 FINAL.pdf PDF
Amnd 0004 20R6012 FINAL.pdf PDF
Amnd 0003 20R6012.pdf PDF
Amnd 0002 20R6012 FINAL.pdf PDF
Amnd 0001 20R6012 FINAL.pdf PDF
19-0038 Protestant Chapel Lead Paint Survey 031220.pdf PDF
N4008519B0038 Drawings.pdf PDF
RFP N6247020R6012.pdf PDF
19-0038 Protestant Chapel Asbestos Survey 031220.pdf PDF
Master PPI Form Template.xls XLS spreadsheet
N4008519B0038 Specs.pdf PDF
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The Walker Group Architecture, Inc PO Box 541, New Bern, NC 28563

252.636.8778 (PHONE)

252.636.8992 (FAX)

WALKER

GROUP

i n c o r p o r a t e d the

ARCHITECTURE

DISCLOSURE OF INFORMATION

CONTRACTOR SHALL COMPLY AS FOLLOWS:

(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-

(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR

(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE

(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL

SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.

(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION

TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.

FIRE ALARM AND MASS NOTIFICATION LEGEND

FIRE ALARM MANUAL PULL STATION, 48" AFF TO ACTUATING ARM, UON

FIRE ALARM/MNS AUDIO/VISUAL (SPEAKER/STROBE) APPLIANCE, CEILING

MOUNTED. SUBSCRIPT INDICATES MINIMUM CANDELA RATING OF

STROBE. TAP SPEAKERS ACCORDINGLY FOR THE SPACE THEY SERVE.

F

S FIRE ALARM SYSTEM PHOTOELECTRIC SMOKE DETECTOR, CEILING MOUNTED

REQ'D REQUIRED

PNL PANEL

NATIONAL ELECTRICAL CODENEC

GROUNDGND

EXIST EXISTING

EXISTING TO REMAINETR

CONDUIT C

UNLESS OTHERWISE NOTEDUON

FIRE ALARM/ MASS NOTIFICATION SYSTEM

AREA OF REFUGE ASSISTANCEARA

ABBREVIATIONS

ABOVE FINISHED GRADEAFG

ABOVE FINISHED FLOORAFF

FAMN

BELOW FINISHED GRADEBFG

FIRE ALARM/MASS NOTIFICATION

CONTROL PANEL

FIRE ALARM AUDIO (SPEAKER) APPLIANCE, 80" AFG, WALL MOUNT,

SUBSCRIPT "WP" INDICATES WEATHER PROOF.

MASS NOTIFICATION SYSTEMMNS

FIRE ALARM/MASS NOTIFICATION CONTROL PANEL

GENERAL FIRE ALARM NOTESFIRE ALARM DEMOLITION NOTES

GENERAL: DEMOLITION DRAWINGS ARE BASED ON EXISTING PLANS AND

FIELD INVESTIGATION PRIOR TO DEMOLITION. VISIT THE EXISTING

BUILDING PRIOR TO BID IN ORDER TO BECOME FAMILIAR WITH THE

EXISTING CONDITIONS AND IN ORDER TO AVOID CONFLICTS. THE

CONTRACTOR MUST PROTECT AND PRESERVE ALL EXISTING WORK NOT

PART OF PROJECT.

DASHED ITEMS: ITEMS SHOWN DASHED ON DEMOLITION PLANS ARE

EXISTING AND MUST BE REMOVED.

SOLID ITEMS: ITEMS SHOWN SOLID ON DEMOLITION PLANS ARE EXISTING

TO REMAIN.

EXISTING CONDUIT: EXISTING CABLING MUST BE REPLACED. EXISTING

CONDUITS THAT WILL NOT BE REUSED MUST BE REMOVED WHERE THEY

WILL BE EXPOSED UPON COMPLETION OF NEW WORK. EXISTING CONDUIT

TO REMAIN CONCEALED IN WALLS MUST BE ABANDONED. EXISTING

CONDUIT TO REMAIN BELOW FLOOR SLAB MUST BE CUT OFF ONE INCH

BELOW ROUGH FLOOR AND GROUTED FLUSH. REMOVE WIRING FROM

CONDUIT THAT IS ABANDONED.

REPAIR DAMAGE: EXERCISE CARE IN REMOVAL OF DEMOLITION ITEMS.

REPAIR, AT NO ADDITIONAL COST TO THE OWNER, ANY DAMAGE CAUSED

TO EXISTING CONSTRUCTION AND/OR EQUIPMENT TO REMAIN.

DEMOLISHED MATERIALS: MATERIALS REMOVED UNDER DEMOLITION,

NOT TO BE RELOCATED OR DESIGNATED TO BE TURNED OVER TO THE

OWNER, WILL BECOME THE PROPERTY OF THE CONTRACTOR AND MUST

BE REMOVED COMPLETELY FROM THE SITE.

SCHEDULE OUTAGES: SCHEDULED OUTAGES MUST BE COORDINATED

THROUGH THE GOVERNMENT CONSTRUCTION MANAGER OR

CONTRACTING OFFICER.

NOTIFICATION: NOTIFY THE GOVERNMENT CONSTRUCTION MANAGER OR

CONTRACTING OFFICE PRIOR TO TURNING OFF CIRCUITS.

GENERAL: UNLESS SPECIFICALLY INDICATED OTHERWISE, WORK

SHOWN ON FIRE ALARM DRAWINGS IS NEW WORK TO INCLUDE THE FIRE

ALARM/MASS NOTIFICATION PANEL, DEVICES, AND APPLIANCES ON

DRAWINGS FOR A COMPLETE AND OPERATIONAL SYSTEM.

COORDINATION: THE CONTRACTOR MUST REVIEW CONTRACT

DOCUMENTS INCLUDING FIRE ALARM DRAWINGS AND SPECIFICATIONS.

CONTRACTOR MUST COORDINATE AND ADJUST ACCORDINGLY AS

DIRECTED BY THE COTR.

AS-BUILT DRAWINGS: SECURE AN EXTRA SET OF DRAWINGS TO BE

KEPT ON SITE AND MARK DAILY, THE DRAWINGS IN RED AS THE

PROJECT PROGRESSES IN ORDER TO KEEP AN ACCURATE RECORD OF

ALL DEVIATIONS BETWEEN THE WORK SHOWN ON THE DRAWINGS AND

THE WORK WHICH IS ACTUALLY INSTALLED. THESE MARKED DRAWINGS

MUST REFLECT ANY AND ALL CHANGES AND REVISIONS TO THE

ORIGINAL DESIGN WHICH EXISTS IN THE COMPLETED WORK. DELIVER

THE MARKED DRAWINGS TO THE COTR AT PROJECT CLOSE-OUT. IN

ADDITION, PROVIDE CONTACT ID POINT DESCRIPTIONS FOR EACH

DEVICE.

INSPECTIONS: ARRANGE NECESSARY INSPECTIONS. DELIVER

REQUIRED INSPECTION CERTIFICATES TO THE GOVERNMENT.

LABELING: ALL CONDUIT, JUNCTION/BACKBOXES, COVERS AND

COUPLINGS, WHEN PROVIDED, MUST BE FACTORY PAINTED RED IN

UNFINISHED AREAS (E.G. ABOVE CEILINGS, MECHANICAL ROOMS, ETC.).

ALL CONDUIT, JUNCTION/BACKBOXES, COVERS AND COUPLINGS, WHEN

PROVIDED, ARE PERMITTED TO BE PAINTED TO MATCH THE ROOM

FINISHING IN FINISHED AREAS. THE INSIDE COVER OR THE JUNCTION

BOX MUST BE IDENTIFIED AS "FIRE ALARM" AND THE CONDUIT MUST

HAVE PAINTED RED BANDS 3/4" WIDE AT 20' INTERVALS ON BOTH SIDES

OF ALL FLOOR, WALL, AND CEILING PENTRATIONS. LABEL ALL JUNCTION

BOXES WITH CIRCUIT DESIGNATIONS OF THE CABLING INSIDE. PROVIDE

LEGIBLE TYPED LABEL ON ALL ADDRESSABLE DEVICES TO INDICATE ITS

ADDRESS. FOR ANY DEVICE LOCATED ABOVE ACCESSIBLE CEILING,

ATTACH A LEGIBLE TYPED LABEL TO THE CEILING GRID INDICATING THE

DEVICE NOMENCLATURE AND ADDRESS.

WORKING CLEARANCE: COORDINATE FINAL LOCATIONS OF FIRE ALARM

EQUIPMENT WITH MECHANICAL DUCTWORK, PIPING ETC. AND ASSURE

WORKING CLEARANCE WILL BE MET. SUFFICIENT ACCESS AND

WORKING SPACE MUST BE PROVIDED AND MAINTAINED AROUND FIRE

ALARM EQUIPMENT AS REQUIRED BY THE NATIONAL ELECTRICAL CODE.

CONTRACTOR MUST COORDINATE FINAL LOCATION OF EQUIPMENT

PROVIDED.

LOCAL OPERATING CONSOLELOC

MOUNTING HEIGHTS: MOUNTING HEIGHTS INDICATED ARE FROM THE

FINISHED FLOOR TO THE CENTERLINE OF THE DEVICE UNLESS

OTHERWISE NOTED.

FIRE STOPPING: FOR WALL OR FLOOR PENETRATIONS THROUGH

FIRE-RATED STRUCTURES PROVIDE FIRE-STOPPING TO SEAL THE

PENETRATIONS AFTER THE CONDUIT HAS BEEN INSTALLED. FIRE

STOPPING FOR PENETRATIONS MUST BE UL APPROVED PER THE

PENETRATION MADE IN ORDER TO MAINTAIN FIRE-RATED INTEGRITY OF

THE STRUCTURE.

FIRE ALARM COORDINATION: THE ELECTRICAL CONTRACTOR MUST

COORDINATE WITH THE FIRE ALARM SYSTEM PROVIDER AND PROVIDE

POWER CONNECTIONS TO COMPONENTS WHETHER SHOWN OR NOT.

MANUFACTURERS REQUIRE VARYING QUANTITIES OF POWER

CONNECTIONS FOR EQUIPMENT LIKE EXPANDER PANELS AND POWER

SUPPLIES. THESE DEVICES ARE DEPENDENT UPON THE SPECIFIC

MANUFACTURERS SYSTEM. THE FIRE ALARM SYSTEM SUPPLIER MUST

NOTIFY THE OTHER APPROPRIATE SUB-CONTRACTORS ABOUT THESE

REQUIREMENTS AND CONNECTION MUST BE PROVIDED AS PART OF

THE PROJECT.

FIRE ALARM EQUIPMENT SURVIVAL: A SMOKE DETECTOR IS REQUIRED

AT ALL CONTROL PANEL LOCATIONS (I.E. FIRE ALARM PANEL,

NOTIFICATION EXTENDER PANELS, TRANSMITTERS, ETC.).

CONTRACTOR MUST PROVIDE SYSTEM SMOKE DETECTORS FOR ALL

LOCATIONS OF FIRE ALARM PANELS, TO INCLUDE THOSE SHOWN AND

THOSE THAT ARE ADDED BY THE CONTRACTOR FOR THEIR SPECIFIC

DESIGN.

CONDUIT: ALL ADDED FIRE ALARM/MASS NOTIFICATION SYSTEM WIRING

MUST BE INSTALLED IN CONDUIT (EMT MINIMUM). EXISTING EMT MAY BE

REUSED WHERE IT SATISFIES REQUIREMENTS OF NFPA 70.

CONDUIT SEALS: PROVIDE CONDUIT SEAL IN ACCORDANCE WITH NFPA

70 300.7 TO RACEWAYS EXPOSED TO DIFFERENT TEMPERATURES.

CONDUCTORS: ALL CONDUCTORS MUST BE REPLACED WITH NEW.

INTELLIGIBILITY LEVEL: CONTRACTOR MUST VERIFY INTELLIGIBILITY

LEVEL BY MEASUREMENT AFTER INSTALLATION OF 0.7 CIS FOR NAVY

AND MARINE CORP PROJECTS. COMMERCIALLY AVAILABLE TEST

INSTRUMENTATION MUST BE USED TO MEASURE INTELLIGIBILITY AS

SPECIFIED BY IEC 60849 AND IEC 60268-16. THE MEAN VALUE OF AT

LEAST THREE READINGS MUST BE USED TO COMPUTE THE

INTELLIGIBILITY SCORE AT EACH TEST LOCATION.

3/4" CONDUIT

W/ PULL STRING

EXISTING

EXTERNAL

ANTENNA

25' MAXIMUM

DEDICATED 120V, 20A CIRCUIT

FROM SAME SOURCE THAT

FEEDS FAMN.

F S

TO OTHER

ADDRESSABLE

DEVICES

TO OTHER

ADDRESSABLE

DEVICES

1. THE FIRE ALARM AND DETECTION SYSTEM IS TO

BE FULLY COMPLIANT WITH THE CURRENT

EDITIONS OF UFC 3-600-01, UFC 3-600-10N, UFC

4-021-01, AND NFPA 72 FOR A FIRE ALARM AND AN

EMERGENCY VOICE ALARM COMMUNICATION

SYSTEM. THE SYSTEM IS DESIGNED TO INTERFACE

WITH THE SITE MNS.

2. THE FAMN SHALL BE CAPABLE OF ACCEPTING 10

VOLTS ROOT MEAN SQUARED (VRMS), 25 VRMS,

70.7 VRMS AND/OR LINE LEVEL (.707 VRMS) AUDIO

INPUTS.

3. FAMN SHALL BE CONFIGURED TO ACCEPT DRY

CONTACT INPUT FROM AN EXTERNAL INTERFACE

TO ALERT THE FIRE ALARM PANEL THAT A MNS

MESSAGE IS FORTHCOMING. THE FIRE ALARM

PANEL SHALL BE CONFIGURED SO THAT WHILE

THIS INPUT IS ACTIVE (CONTACT CLOSED) THE

FIRE ALARM PANEL SHALL ROUTE AUDIO

PROVIDED BY THE MNS INTERFACE DIRECTLY TO

ALL CONNECTED FIRE ALARM SPEAKERS. THE

SYSTEM SHALL BE PROGRAMMED SO THIS

EXTERNAL AUDIO INPUT WILL RECEIVE HIGHEST

PRIORITY AND OVERRIDE ALL FIRE ALARM

NOTIFICATION SO LONG AS THE INPUT IS ACTIVE.

WHEN THE INPUT GOES INACTIVE (CONTACT

OPEN) THE EXTERNAL AUDIO ROUTING WILL

CEASE AND THE FIRE ALARM PANEL SHALL

AUTOMATICALLY RETURN TO THE PRIOR

NOTIFICATION PROGRAM THAT WAS ACTIVE

BEFORE THE MNS MESSAGE.

4. FAMN SHALL BE COMPATIBLE AND OPERABLE

WITH THE EXISTING FIRE ALARM SUPERVISING

STATION SHUREGUARD II. EXISTING BASEWIDE

MASS NOTIFICATION REPORTING SYSTEM IS A

COOPER INDUSTRIES WAVES SYSTEM.

CONTRACTOR SHALL PROVIDE ALL EQUIPMENT

AND LABOR REQUIRED TO CONNECT THE NEW

FIRE ALARM AND DETECTION SYSTEM TO THE

BASE'S SUPERVISING STATION. WAVES SYSTEM

TRANSCEIVER TO BE PROVIDED BY THE

GOVERNMENT.

5. DACT SHALL BE CONFIGURED TO TRANSMIT

SIGNALS IN CONTACT ID FORMAT.

6. SIGNALS TRANSMITTED OVER THE PRIMARY AND

SECONDARY MEANS OF TRANSMISSION SHALL BE

POINT SPECIFIC WITH EACH ADDRESS AND

CONDITION INDICATED AT THE FIRE ALARM PANEL

TRANSMITTED SEPARATELY. ALL FIRE ALARMS,

SUPERVISORY ALARMS, AND TROUBLE

CONDITIONS SHALL BE TRANSMITTED TO THE

SUPERVISING STATION. CONNECTION TO THE

FIRE ALARM REPORTING SYSTEM AND

PROGRAMMING OF THE DACT MODULE AND HEAD

END EQUIPMENT SHUREGUARD II SHALL BE

COORDINATED WITH THE FIRE ALARM REPORTING

SYSTEM (FARS) ADMINISTRATOR.

7. PROVIDE A LAMINATED GRAPHIC FLOOR PLAN

ADJACENT TO THE FAMN DEPICTING ALL FIRE

ALARM DEVICES AND EQUIPMENT WITHIN THE

FACILITY.

8. FIRE ALARM PLANS INDICATE AREA OF STROBE

COVERAGE AND ARE DIAGRAMMATIC ONLY.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING

ADDITIONAL SPEAKERS FOR EACH FACILITY TO

MEET ALL MASS NOTIFICATION SYSTEM

INTELLIGIBILITY REQUIREMENTS IN ACCORDANCE

WITH UFC 4-021-01.

9. LABEL ALL DEVICES WITH THEIR ADDRESSES.

FIRE ALARM AND MNS MONITORING NOTES

FAMN

(BLDG 16)

A C

TU

A

TE

C

O M

M O

N A

LA

R

M S

IG

N

A L

A C

TU

A

TE

A

U D

IB

LE

A

LA

R M

S

IG

N A

L

A C

TU

A

TE

C

O M

M O

N S

U P

E R

V

IS

O R

Y S

IG

N

A L

IN

D

IC

A

TO

R

A C

TU

A

TE

A

U D

IB

LE

S U

P E

R V

IS

O

R Y

S

IG

N A

L

A C

TU

A

TE

C

O M

M O

N T

R O

U B

LE

S

IG

N

A L

IN

D

IC

A

TO

R

A C

TU

A

TE

A

U D

IB

LE

C O

M M

O N

T R

O U

B

LE

S

IG

N A

L

A C

TI

V

A

TE

D

IS

P

LA

Y O

N F

A C

P A

N D

A N

N U

N C

IA

TO

R S

A C

TU

A

TE

A

U D

IB

LE

E V

A C

U A

TI

O

N S

IG

N

A

LS

V

O

IC

E M

E S

S A

G E

A C

TI

V

A

TE

V

IS

U A

L E

V A

C U

A

TI

O N

S

IG

N A

LS

TR

A

N S

M

IT

F

IR

E A

LA

R

M S

IG

N

A L

TO

S

U P

E R

V

IS

IN

G

S

TA

TI

O

N

S H

U T

D O

W N

A S

S O

C

IA

TE

D

A H

U

O V

E R

R

ID

E O

TH

E

R M

E S

S A

G E

S

A C

TI

V

A

TE

A U

D

IB

LE

A

N D

V

IS

U A

L S

IG

N

A

LS

CONTROL UNIT ANNUNCIATION NOTIFICATION SUPP.

SYSTEM INPUTS BELOW A B C D E F G H I J K L M

1 MANUAL FIRE ALARM BOXES X X X X X X 1

2 SMOKE DETECTORS X X X X X X 2

3 3

4 4

5 5

FIRE ALARM AC POWER FAILURE X X X

FIRE ALARM SYSTEM LOW BATTERY X X X

OPEN CIRCUIT X X X

GROUND FAULT X X X

NOTIFICATION APPLIANCE CIRCUIT SHORT X X X

A B C D E F G H I J K L M

SYSTEM OUTPUT BELOW

LOCAL OPERATING CONSOLE (LOC) X

DUCT SMOKE DETECTORS X X X X X X X

TR

A

N S

M

IT

T R

O U

B

LE

S

IG

N A

L

TO

S U

P E

R V

IS

IN

G S

TA

TI

O N

X

X

X

X

X

TRX-401

TRANSCEIVER

FINISHED

WALL

WALL MOUNTED

SMOKE DETECTOR

HEAT DETECTORS

NEVER HERE

CEILING MOUNTED

SMOKE/HEAT DETECTOR

ACCEPTED HERE

4" 12"

MAX

CEILING

3' MINIMUM

A/C SUPPLY OR

RETURN

DIFFUSER

MAGNETIC

DOOR

HOLDER 5"

DOOR

WIDTH

LESS 3"

MANUAL

PULL

STATION

TO EXIT

DOOR 5'

MAXIMUM

42"MIN TO 48"

MAX TO TOP OF

PULL HANDLE

92" MIN AFF

AUDIBLE

ONLYAUDIBLE/VISUAL

& VISUAL ONLY

APPLIANCES

SYNCHRONIZE

MORE THAN TWO

APPLIANCES IN

ANY FIELD OF

VIEW.

F I R EF I R E

FOR CEILING HEIGHTS LESS THAN 86"

THE VISUAL LENS MOUNTING HEIGHT

SHALL BE WITHIN 6" OF THE CEILING

96"

MAXIMUM

AFF

80"

MINIMUM

AFF

FINISHED FLOOR

NOTE: MEASUREMENTS

SHOWN ARE TO THE CLOSEST

EDGE OF THE DETECTOR

6" MINIMUM BFC

D A

C T

(2) CAT6 UTP TO TELEPHONE PATCH PANEL

FINAL TERMINATIONS BY GOVERNMENT

PATCH PANEL

PRIMARY + BACKUP

(2) CAT6 UTP

(GREEN)

D

TO AHU

SHUTDOWN

FIRE ALARM/MASS NOTIFICATION INPUT-OUTPUT MATRIX

SCALE: NO SCALEA

FIRE ALARM SYSTEM DEVICE MOUNTING HEIGHT DETAIL

SCALE: NO SCALEB

FIRE ALARM/MASS NOTIFICATION SYSTEM RISER DIAGRAM

SCALE: NO SCALEC 4/30/20

S

WP

S

WP

NETWORK

TELEPHONE

F S

TO OTHER

ADDRESSABLE

DEVICES

TO OTHER

ADDRESSABLE

DEVICES

FAMN

(BLDG 16A)

D A

C T

S

WP

S

WP

(2) CAT6 UTP TO TELEPHONE PATCH PANEL

FINAL TERMINATIONS BY GOVERNMENT

PATCH PANEL

PRIMARY + BACKUP

NETWORK

TELEPHONE

3/4" CONDUIT

W/ PULL STRING

25' MAXIMUM

TRX-401

TRANSCEIVER

EXTERNAL

ANTENNA

5'

M A

X

IM

U M

C A

B

LE

L E

N G

TH

2"C FOR INTERCONNECTION

( CABLING PER MANUFACTURERS

RECOMMENDATIONS)

S

S

FIRE ALARM AUDIO/VISUAL (HORN/STROBE) APPLIANCEF

FIRE ALARM VISUAL (STROBE) APPLIANCEF

(2) CAT6 UTP

(GREEN)

1 REVISION 1 6/6/2020

Sheets and Views
FA001 GENERAL NOTES, LEGEND AND ABBREVIATIONS

File details come from the government source that posted it. Updated .