This is a request for proposal for surface fire fighter and damage control contractor operation and maintenance services. The solicitation seeks proposals to provide maintenance and support for training systems and equipment at seven commands located in Mayport, FL, Norfolk, VA, Newport, RI, San Diego, CA, Pearl Harbor, HI, RTC Great Lakes, IL, and SWOSU Great Lakes, IL. The effort is a 100% small business set-aside. The contract will be a firm-fixed-price contract with one base year and four option years, and also includes cost reimbursable lines for consumable products. The applicable NAICS code is 541330 with a size standard of $41.5M. The proposal due date is listed in block 9 of the RFP SF 33. The document also notes a deviation to the limitations on subcontracting clause at FAR 52.219-14 that allows small business primes to count certain first-tier subcontracted work as if performed by the prime itself.
View the file
Other files
Show 40 more
Latest 50 of 87 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CDRL A004 ~ Monthly Report
(DI-MISC-81392)
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor August 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: August-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 3-Sep-19
SECTION IV ~ MAINTENANCE ACTIONS
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 4 0 22 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 4 0 22
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
TSG SCBA PAK #5 9227:0700 9227:0730 0.50 9227:0700 0.50 0
TSG SCBA PAK #50 9227:0730 9227:0800 0.50 9227:0730 0.50 0
TSG SCBA PAK #34 9227:1030 9227:1130 1.00 9227:1030 1.00 0
TSG SCBA PAK #14 9227:1130 9227:1230 1.00 9227:1130 1.00 0
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor August 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: August-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 3-Sep-19
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 1 TSG 1 - SCBA Pak #5 was leaking air from hand wheel on 57264-00/Packing 15-Aug-19 15-Aug-19 0 high pressure hose.
- Found packing on high pressure hose nipple broken.
Replaced packing on nipple, reconnected high pressure hose to SCBA bottle and found no apparent leaks.
Returned pack to student staging in readiness condition.
2 TSG 1 - SCBA Pak #50 was leaking air in the HUD console 10005959/packing, preformed 15-Aug-19 15-Aug-19 0 assembly.
- Found preform packing on gauge to be worn out.
Replaced preform packing, repressurized pack and found no apparent leaks. Returned pack to student staging with no apparent leaks.
3 TSG 1 - SCBA Pak #34 would not activate vibralert when 802919-01/regulator body-sub assembly 15-Aug-19 15-Aug-19 0 air pressure went low.
- Replaced regulator body, pressurized pack, simulated low air pressure and vibralert sounded. Returned pack to student staging in readiness condition.
4 TSG 1 - SCBA Pak #14 would not activate vibralert when 802919-01/regulator body-sub assembly 15-Aug-19 15-Aug-19 0 air pressure went low.
- Replaced regulator body, pressurized pack, simulated low air pressure and vibralert sounded. Returned pack to student staging in readiness condition.
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor July 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Month Ending: July-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Aug-19
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 0 3 18 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 0 3 18
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor July 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: July-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Aug-19
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor June 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Month Ending: June-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Jul-19
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 3 7 18 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 3 7 18
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
Facility Bauer UNII Air Flask #4 9168:0600 3.00 9168:0600 3.00 0 19F6 MMR Combustible Gas Sensor#1 9177:0630 9177:0730 1.00 9177:0630 1.00 0 TSG SCBA Pak #1 9177:0830 9177:0930 1.00 9177:0830 1.00 0
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor June 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: June-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Jul-19
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to
1 Facilities 1 - While attempting to remove bushing to replace o-ring, CYL-0009/ASME StorageVessel 5-Jun-19 bushing was hard to remove.
6/5/2019 - Removed air flask and took to Ed Dangs Machine Works and they were able to remove bushing but threads were galled and cross threaded.
6/06/2019 - Called Bauer rep to see if it is safe to run compressor with 3 flasks, he replied that the compressor can be ran with just 2 flasks because that is what it originally comes with and any more would be an option. Contacted Norris Cylinder about ASME approved repair companies.
6/14/2019 - Received quote from Pressure Systems to replace flask. Received list of ASME approved repair companies and started calling around to see who could repair flask.
6/17/2019 - Sent quote from Pressure Systems to COR and he sent it to Jeff Mendoza. Called Clark's Meter Calibration and they asked for pictures so the technician that would do the repair could determine if he could take on task.
6/18/2019 - Jeff Mendoza asked COR to send ina quote along with a purchase request and he would give it to Ed Crawford. Clark's said they couldn't do repair and recommended Latigo Construction, Spoke to Harold and he said they have the capability to bore and rethread flask for $5000.
6/19/2019 - Purchase request was approved by Ed Crawford and sent to Norfolk to be processed by Elena.
2 19F6 1 - While performing calibration on MMR trainer, gas 006824-001/Combustible Gas Sensor 26-Jun-19 26-Jun-19 0 sensor #1 (GS1) gave a replace sensor message.
- Removed and replaced gas sensor #1 with a new one from spare. Calibrated and tested SAT. Returned system to readiness condition.
3 TSG 1 - While performing PM M-1R on SCBA Pak #1, found 804476-03/Side Strap 26-Jun-19 26-Jun-19 0 frayed waist and side straps. 804085-07/Waist Strap
- Replaced frayed waist straps and side straps, returned SCBA pack to storage area.
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor May 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Month Ending: May-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 3-Jun-19
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 7 0 15 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 7 0 15
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
20C28 Chlorinator Hose 9122:0545 9122:0615 0.50 9122:0545 0.50 0 TSG Battle Lantern 9126:0600 9126:0700 1.00 9126:0600 1.00 0
Facilities Bauer UNII Air Flasks 9126:1100 9126:1300 2.00 9126:1100 2.00 0 19F6 Pilot Assem 2 9133:0530 9133:0600 0.50 9133:0530 0.50 0
Facilities Laundry Dryer 9133:0630 9133:0730 1.00 9133:0630 1.00 0 20C28 Strobe Light 9143:0700 9143:0800 1.00 9143:0700 1.00 0
Facilities Bauer MINI Unicus 9149:0700 9149:1100 4.00 9149:0700 4.00 0
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor May 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: May-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 3-Jun-19
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to
1 20C28 1 - While checking water chemistry, noticed hose that SPGE25 / 3/8" x 1/4" polyethylene tubing 2-May-19 2-May-19 0 attached from return pipe to chlorinator had a leak.
- Replaced hose, tested system for leaks and found none. Returned systemto readiness condition.
2 TSG 1 - While performing weekly DORT, found one battle Portable Battle Lantern 6-May-19 6-May-19 0 lantern not functioning. Upon further inspection found water had leaked into unit.
- Disassembled portable battle lantern and serviced all internal parts. Reassembled and test as necessary.
Returned lantern to readiness condition.
3 Facilities 1 - While filling SCBA bottles, noticed air leaks on O-ring 6-May-19 6-May-19 0 bottom of flasks 1,2,and 3, and the top of flask 4.
- Replaced o-rings on flasks, ran compressor and found no apparent leaks. Returned compressor to normal operating condition.
4 19F6 2 - While performing DORT on AV trainer, pilot #2 35-703917-007/Ignition Controller 13-May-19 13-May-19 0 would go to flame but not prove.
- Replaced pilot #2 ignition controller and tested system with no apparent issues. Returned trainer to readiness condition.
5 Facilities 1 - Dryer had a scraping sound when in operation. 70568201/Kit, Roller and Seal 13-May-19 13-May-19 0 after further investigation found guide rollers worn.
- Replaced guide rollers and sound went away.
returned system to readiness condition.
6 20C28 1 - While performing E-Drain functional test, noticed 141ST-120R/ Strobe Light 22-May-19 22-May-19 0 that the strobe light was not flashing.
- Checked voltage on all electrical lines, inspected and tested relays, fuses, solid state relays and strobe light unit. Found unit to be bad. Replaced unit and tested E-Drain with no further problems. Returned trainer to readiness condition.
7 Facilities 1 - After starting MINI Unicus SCBA compressor, KIT-N16382/Solenoid Repair Kit 29-May-19 29-May-19 0 noticed that the air flasks were not filling.
- Removed, cleaned and re-lubricated o-rings on condensate drain valve and problem still persisted.
Removed solenoid and replaced all internal parts with solenoid rebuild kit. Started system and air flasks started filling. Returned system to readiness condition.
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor April 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Month Ending: April-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-May-19
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 0 7 8 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 0 7 8
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor April 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: April-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-May-19
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor March 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Month Ending: March-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Apr-19
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 7 1 8 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 7 1 8
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
20C28 Water Supply Valve Relay 9063:1000 9063:1100 0.50 9063:1000 0.50 0 19F6 Bilge FP 9070:0500 9070:0800 3.00 9070:0500 3.00 0 TSG SCBA Pak #43 9079:0800 9079:0830 0.50 9079:0800 0.50 0 TSG SCBA Pak #44 9079:0800 9079:0830 0.50 9079:0800 0.50 0 TSG SCBA Pak #42 9079:0800 9079:0830 0.50 9079:0800 0.50 0 TSG SCBA Pak #12 9079:0830 9079:0900 0.50 9079:0830 0.50 0 TSG SCBA Pak #29 9079:0900 9079:0930 0.50 9079:0900 0.50 0
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor March 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: March-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Apr-19
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to
1 20C28 1 - During training, the motorized water supply valve 2961118/Relay 4-Mar-19 4-Mar-19 0 would not actuate.
Referenced long lines and identified relay K-20 for water supply valve motorized valve. Secured power to the trainer, tagged and replaced relay K-20. Removed tag and tested water supply valve with no further issues. Returned trainer to readiness condition.
2 19F6 1 - Bilge pilot failed to prove during morning DORT 981298/Tuf-Hide 11-Mar-19 11-Mar-19 0
- Cleaned thermocouple, replaced spark plug, reseat thermo couple plug wires, replaced flamerod, replaced flame safeguard program module, replaced flame safeguard amplifier module, overhauled bilge pilot, and checked ground wire had a good connection. Tested the bilge pilot after every change and still the bilge pilot would not prove. Replaced flamerod wire that runs from flame relay in FHM1 to bilge flamerod.
Bilge tested SAT. returned system to readiness condition.
3 TSG 1 - While performing maintenance, technicians found 804476-03/side straps 20-Mar-19 20-Mar-19 0 exposed wires on low pressure hose, frayed side and 804085-07/waist straps waist straps, and worn hip and shoulder padding. 803810-04/hip/shoulder pad kit
- Replaced low pressure hose, straps and padding. 200449-02/low pressure hose Tested pack and returned pack to readiness condition.
4 TSG 1 - While performing maintenance, technicians found 200449-02/low pressure hose 20-Mar-19 20-Mar-19 0 exposed wires on low pressure hose.
- Replaced low pressure hose, tested pack and returned pack to readiness condition.
5 TSG 1 - While performing maintenance, technicians found 804476-03/side straps 20-Mar-19 20-Mar-19 0 Frayed side and waist straps, and worn hip and 804085-07/waist straps shoulder padding. 803810-04/hip/shoulder pad kit
- Replaced straps and padding and returned pack to readiness condition.
6 TSG 1 - While performing maintenance, technicians found 804476-03/side straps 20-Mar-19 20-Mar-19 0 Frayed side and waist straps, and worn hip and 804085-07/waist straps shoulder padding. 803810-04/hip/shoulder pad kit
- Replaced straps and padding and returned pack to readiness condition.
7 TSG 1 - While performing maintenance, technicians found 804476-03/side straps 20-Mar-19 20-Mar-19 0 Frayed side and waist straps, and worn hip and 804085-07/waist straps shoulder padding. 803810-04/hip/shoulder pad kit
- Replaced straps and padding and returned pack to readiness condition.
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor February 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Month Ending: February-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Mar-19
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 1 0 1 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 1 0 1
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
19F6 MMR Bilge Thermocouple 9032:0530 9032:0630 1.00 9032:0530 1.00 0
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor February 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: February-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Mar-19
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to
1 19F6 1 - While performing DORT procedures an error KQIN-316U-12/Thermocouple 1-Feb-19 1-Feb-19 0 occurred: Bilge pilot failed to prove.
- After cleaning and adjusting thermocouple, bilge pilot still failed to prove. Replaced thermocouple and tested pilot with no apparent issues. Completed DORT and returned MMR to readiness condition.
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor January 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Month Ending: January-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Feb-19
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 2 0 70 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 2 0 70
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
19F6 EE1/Drawn Sample Pump 9007:0600 9007:0900 3.00 9007:0600 3.00 0 19F6 Comb. Gas Sensor #2 9024:0600 9024:0700 1.00 8292:0800 1.00 97
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor January 2019.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: January-19
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Feb-19
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to
1 19F6 2 - While starting aviation trainer, the drawn sample 5/8" polyurathane hose 7-Jan-19 7-Jan-19 0 assembly pump was not pumping and the pump was getting hot.
- Checked power going to motor and there was proper voltage, replaced pump motor and there was no change, removed inlet hoses and blew them out to be sure there were no obstructions and still no change, removed exhaust hose and found that it was clogged.
Replaced clogged hose and started system with no apparent issues. Returned system to readiness condition.
2 19F6 1 - While attempting to calibrate combustible gas sensor, 006824-001/Combustible Gas Sensor 24-Jan-19 24-Jan-19 0 a message came up to replace sensor.
- Replaced bad combustible gas sensor with a new sensor from spare parts. Calibrated system and was able to complete weekly span with no apparent issues.
Returned system to readiness condition.
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor December 2018.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Month Ending: December-18
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 2-Jan-19
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 0 1 68 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 0 1 68
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor December 2018.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: December-18
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 2-Jan-19
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor November 2018.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Month Ending: November-18
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 3-Dec-18
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 1 5 68 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 1 5 68
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
1 19F6 Pilot assembly/Flame rods 8319:1000 8319:1100 1.00 8319:1000 1.00 0
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor November 2018.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: November-18
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 3-Dec-18
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to
1 19F6 2 - While performing routine maintenance on AV pilot Kidde 45/Flame Rod 15-Nov-18 15-Nov-18 0 assemblies, found flame rods on pilots 1 and 3 damaged.
- Removed pilot assemblies, cleaned and inspected all components and replaced flame rods on pilot boxes 1 and 3. Re-installed pilot assemblies, adjusted flame rod gaps and tested pilots with no apparent issues.
Returned trainer to readiness condition.
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor October 2018.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Month Ending: October-18
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Nov-18
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 5 16 67 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 5 16 67
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
1 19F6 Fan Driver 8282:0700 8282:0900 2.00 8282:0700 2.00 0 2 19F6 Fan Driver 8291:1000 8291:1300 3.00 8291:1000 3.00 0 3 19F6 Comb Gas Sensor #2 8292:0800 8292:0830 0.50 8292:0800 0.50 0 4 20C28 Supply Pump 8302:0945 8302:1045 1.00 8302:0945 1.00 0 5 19F6 MMR Pendant Assembly 8304:0600 8304:0630 0.50 8304:0600 0.50 0
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor October 2018.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: October-18
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Nov-18
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part
# & Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to
1 19F6 1 - While bringing up MMR trainer, the fans did not GS3-4020/Fan Driver 9-Oct-18 9-Oct-18 0 start up. Inspected enclosure SP3 and found the 40 amp breakerwas tripped and looked burnt. Opened fan driver enclosure and found the cover blown off and an odor of burnt insulation.
- 10/09/2018 - Verified system was de-energized, locked and tagged fan driver enclosure knife switch.
Awaiting replacement of 40 amp breaker to test system.
- 10/18/2018 - NAVFAC replaced breaker box and both breakers within panel. Wired in fan driver, energized system and ran vent fans with no apparent issues. Removed currently installed fan driver, installed and programmed spare fan driver and tested system with no apparent issues. Re-installed older fan driver and returned MMR to readiness condition.
2 19F6 2 - While performing system startup on the AV trainer, GS3-4040/Fan Driver 18-Oct-18 18-Oct-18 0 noticed the vent fan would start then shutdown during the startup sequence. While verifying parameters and troubleshooting, we found the AV fan driver had a "OVER TEMPERATURE" error.
- Removed and replaced fan driver, verified parameters were correct and tested with no apparent issues.
Returned system to readiness condition.
3 19F6 1 - While performing calibration on combustible gas 006824-001/Combustible Gas Sensor 19-Oct-18 19-Oct-18 0 sensor #2, there was an error of "Replace Sensor".
- Removed #2 sensor and replaced with spare from inventory. Calibrated sensor and completed system spanning with no other issues. Returned system to readiness condition.
4 20C28 1 - Toward the end of the wet trainer scenario, a loud ES10-R/Rexnord Omega Coupling 29-Oct-18 29-Oct-18 0 humming/rattling was heard coming from the supply pump. Removed coupling guard and found the flex coupling starting to separate and pieces were breaking off.
- Locked and tagged supply pump, removed deteriorated flex coupling and replaced with a new one we had in spares. Ran supply pump and excessive noise went away. Returned trainer to readiness condition.
5 19F6 1 - While performing DORT on the MMR, found the TH590002/Incandescent Lamp 31-Oct-18 31-Oct-18 0 smoke button not illuminating. Further inspection showed the smoke button actuator button was loose and the incandescent lamp was burnt out.
- Disassembled the control pendant to tighten the smoke button actuator and replace the incandescent lamp. Tested pendant with no further issues. Returned trainer to readiness condition.
* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor September 2018.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
Contract: N61339-10-D-2002 Task 0002 Contractor: Month Ending: September-18
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Oct-18
(1) CORRECTIVE MAINTENANCE ACTIONS
Corrective Maintenance Actions Current Month Previous Month Fiscal Year
To-Date
On-Site 16 8 62 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0
Totals: 16 8 62
(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)
Training System Major-Subsystem / Assembly Julian Date & Time Failed
Julian Date & Time Restored
Time to Repair (Hours)
Julian Date/Time
Last Failure Average MTTR Todate (Hours)
Average MTBF Todate (Days)
1 TSG SCBA Pak # 11 8249:0900 8249:1000 1.00 8249:0900 1.00 0 2 TSG SCBA Pak # 10 8249:1000 8249:1100 1.00 8107:0630 1.00 142 3 TSG SCBA Pak # 8 8249:1100 8249:1200 1.00 8249:1100 1.00 0 4 TSG SCBA Pak # 9 8249:1200 8249:1300 1.00 8051:1330 1.00 198 5 TSG SCBA Pak # 14 8253:1000 8253:1100 1.00 8253:1000 1.00 0 6 TSG SCBA Pak # 16 8253:1100 8253:1200 1.00 8253:1100 1.00 0 7 TSG SCBA Pak # 27 8255:0800 8255:0900 1.00 8143:1200 1.00 112 8 TSG SCBA Pak # 34 8255:0930 8255:1030 1.00 8107:0730 1.00 99 9 TSG SCBA Pak # 29 8255:1100 8255:1200 1.00 8255:1100 1.00 0
10 TSG SCBA Pak # 33 8268:0600 8268:0700 1.00 8268:0600 1.00 0 11 TSG SCBA Pak # 35 8268:0700 8268:0800 1.00 8268:0700 1.00 0 12 TSG SCBA Pak # 43 8268:0800 8268:0900 1.00 8268:0800 1.00 0 13 TSG SCBA Pak # 46 8268:0900 8268:1000 1.00 8268:0900 1.00 0 14 TSG SCBA Pak # 50 8269:0700 8269:0800 1.00 8085:1000 1.00 184 15 TSG SCBA Pak # 35 8269:0900 8269:1000 1.00 8268:0700 1.00 1 16 TSG SCBA Pak # 56 8269:1000 8269:1100 1.00 8269:1000 1.00 0
DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.
Section V - Fire Fighter Consumables-
Class Statistics and Authenication
CDRL A004 Pearl Harbor September 2018.xls CDRL AOO4 ~ Mthly Report Sect V-Fire Fighter Consumables-Class Statistics~Authenication
CNELS PH, HI
Contract: N61339-10-D-2002 Task 0002 Month Ending: September-18
Command: SWOS ENG LS Pearl Harbor, HI Report Date: 1-Oct-18
Section IV - Maintenance Actions (con't)
(3) REPAIR or REPLENISH
Seq No.
Training System or
Equip S/N Description Failed Repairable or Repair Part (Part #
& Nomenclature)
Date Repairable or Repair Part
Failed
Date Repaired or Replenished
# Days to Repair or Replenish
Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOTreplenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 1 TSG 1 - While performing SCBA functional test on Pak #11, 200083-01/Regulator Diaphragm 6-Sep-18 6-Sep-18 0 the regulator was unable to maintain facepiece vacuum.
- Replaced regulator diaphragm and completed functional test with no further discrepancies.
2 TSG 1 - While performing SCBA functional test on Pak #10, 10007358/Demand Lever 6-Sep-18 6-Sep-18 0 the positive pressure was too high.
- An attempt was made to adjust the demand lever but upon inspection, found the demand lever to be broken. Replaced demand lever and completed functional test with no further discrepancies.
3 TSG 1 - While performing SCBA functional test on Pak #8, 36862-06/Seat O-ring 6-Sep-18 6-Sep-18 0 the primary and secondary lockup pressures were too high.
- Replaced the o-ring on the primary and secondary seat and completed functional test with no further discrepancies.
4 TSG 1 - While performing SCBA functional test on Pak #9, 36862-06/Seat O-ring 6-Sep-18 6-Sep-18 0 the primary lockup pressure was too high.
- Replaced the o-ring on the primary seat and completed functional test with no further discrepancies.
5 TSG 1 - While performing SCBA functional test on Pak #14, 802919-01/Regulator Body 10-Sep-18 10-Sep-18 0 the positive pressure was too high during the static pressure/lockup test.
- Attempted to correct the problem by adjusting the demand lever but was unable to correct the pressure.
Replaced the regulator body and completed the functional test with no discrepancies.
6 TSG 1 - While performing SCBA functional test on Pak # 16, 10005775/Seat 10-Sep-18 10-Sep-18 0 the static pressure/lockup test had an error saying 36862-06/o-ring "Primary Creep Too High".
- Replaced the o-ring and seat in the primary pressure seat retainer. Completed functional test with no further discrepancies.
7 TSG 1 - While performing SCBA functional test on Pak # 27, 10007565/O-ring 12-Sep-18 12-Sep-18 0 the secondary weep hole started leaking air. 10005305/Back-up Ring
- Replaced the o-ring and backup ring on the secondary piston shaft. Completed functional test with no further discrepancies.
8 TSG 1 - While performing SCBA functional test on Pak # 34, 10007565/O-ring 12-Sep-18 12-Sep-18 0 the secondary weep hole started leaking air. 10005305/Back-up Ring
- Replaced the o-ring and backup ring on the secondary piston shaft. Completed functional test with no further discrepancies.
9 TSG 1 - While performing SCBA functional test on Pak # 29, 18002-00/Low Pressure Hose O-ring 12-Sep-18 12-Sep-18 0 found low pressure hose assembly o-ring torn.
- Replaced the o-ring and completed functional test with no further dicrepancies.
10 TSG 1 - While performing SCBA functional test, Pak #33, 804110-03/Regulator Cover 25-Sep-18 25-Sep-18 0 Failed the air saver activation test and vibralert alarm 802865-01/Vibralert activation test.
- Removed regulator cover and attempted to adjust metal tang on regulator cover but was unable to correct air saver activation pressure. Used a new regulator cover and new vibralert and completed functional test with no further discrepancies.
11 TSG 1 - While performing SCBA functional test, Pak #35, 200083-01/Regulator Diaphragm 25-Sep-18 25-Sep-18 0 was unable to maintain a facepiece vacuum.
- Replaced regulator diaphragm and completed functional test with no further discrepancies.
12 TSG 1 - While performing SCBA functional test, Pak #43, 18012-00/Check Valve Assembly O-Ring 25-Sep-18 25-Sep-18 0 failed to transfer from primary to secondary during the secondary pressure at high cylinder pressure test.
- Upon inspection, found the check valve assembly o-ring was damaged. Replaced check valve assembly o-ring and completed functional test with no further discrepancies.
13 TSG 1 - While performing SCBA functional test, Pak #46, 10005229/Regulator Demand Spring 25-Sep-18 25-Sep-18 0 failed the standard breathing rate test.
- Attempted to adjust demand lever to correct the breating rate, but was unable to get the breathing rate within range after several attempts. Replaced demand lever spring and completed functional test with no further discrepancies.
14 TSG 1 - While performing maintenance, SCBA Pak #50 had 200449-02/Low Pressure Hose Assembly 26-Sep-18 26-Sep-18 0 HUD LED's not functioning.
- Replaced batteries for HUD and there was no change.
Replaced low pressure hose assembly, re-pressurized pack and the HUD lights came on. Returned pack to student staging in readiness condition.
15…