Att (L-16D) Newport Maint Sep 18 - Aug 19 dtd 7 Oct 19.pdf

PDF 427 KB Posted

Attached to
Surface Fire Fighter and Damage Control Contractor Operation & Maintenance Services
Solicitation number
N61340-20-R-0005
Issued by

About this file

This request for proposal solicits proposals for Surface Fire Fighter and Damage Control Contractor Operation and Maintenance Services. The services include providing all labor, materials, consumables, equipment, tools, test equipment, and transportation necessary to maintain training systems and equipment at seven commands located across six geographic locations, including Mayport, FL, Norfolk, VA, Newport, RI, San Diego, CA, Pearl Harbor, HI, RTC Great Lakes, IL, and SWOSU Great Lakes, IL. The government seeks a firm-fixed price contract with a one-year base and four one-year options, as well as cost reimbursable lines for consumable products. The applicable NAICS code is 541330 and size standard is $41.5M. This is a 100% small business set-aside. The proposal due date is listed in the RFP SF 33. Point of contacts are listed in Section L. The internal MOPAS documentation was inadvertently distributed but posted now to maintain integrity.

View the file

Other files

File Type Posted
Att (L-9B) Surf FF-DC Manpower Projection Workbook_23 Dec 2019.xlsx XLSX spreadsheet
Att (1) Surface FF-DC COMS PWS_2 Dec 2019_TrkChgs.DOCX DOCX document
Att (L-14) Consolidated Solicitation Question_19 Dec 2019 Amend 0001.xlsx XLSX spreadsheet
ATCH 10I_CBA_San Diego - SDAMP - FINAL.PDF PDF
Att (L-9B) Surf FF-DC Manpower Projection Workbook_20 Dec 2019.xlsx XLSX spreadsheet
Att (1A) Appendix A_Surf FF-DC_Mayport_4 Dec 2019_TrkChgs.docx DOCX document
ATCH 10J_CBA_Newport - NFSMWA - FINAL.PDF PDF
Att (1G) Appendix G_Surf FF-DC_SWOSU Great Lakes_4 Dec 2019_TrkChgs.docx DOCX document
Att (1B) Appendix B_Surf FF-DC_Norfolk_4 Dec 2019_TrkChgs.docx DOCX document
ATCH 10H_CBA_Norfolk - TAMP - FINAL.PDF PDF
Att (1C) Appendix C_Surf FF-DC_San Diego_4 Dec 2019_TrkChgs.docx DOCX document
ATCH 10K_CBA_Pearl Harbor - LMS - FINAL.pdf PDF
Att (1E) Appendix E_Surf FF-DC_Pearl Harbor_4 Dec 2019_TrkChgs.docx DOCX document
.N61340-20-R-0005 Amendment 0001.docx DOCX document
ATCH 10L_CBA_Great Lakes - GLAFFSP - FINAL.PDF PDF
Att (9A) Surf FF-DC Sect B_Price Evaluation Worksht_11 Dec 2019 Amend 1.xlsx XLSX spreadsheet
ATCH 10G_CBA_Mayport - MAMP - FINAL.pdf PDF
Att (9A) Surf FF-DC Sect B_Price Evaluation Worksht_10 Dec 2019.xlsx XLSX spreadsheet
ATCH 10C_WD 15-5636 (Rev.-11) San Diego.pdf PDF
ATCH 10C_CBA_San Diego - SDAMP - FINAL.PDF PDF
ATCH 10D_CBA_Newport - NFSMWA - FINAL.PDF PDF
Surface FF_DC Washer and Dryer List_4 Dec 2019.pdf PDF
ATCH 10E_CBA_Pearl Harbor - LMS - FINAL.pdf PDF
Att (L-12) Surf FF-DC COMS Consumables Report All Sites_4 Dec 2019.xlsx XLSX spreadsheet
ATCH 10B_CBA_Norfolk - TAMP - FINAL.PDF PDF
ATCH 10F_CBA_Great Lakes - GLAFFSP - FINAL.PDF PDF
Att (L-14) Consolidated Solicitation Question_5 Dec 2019 FINAL.xlsx XLSX spreadsheet
ATCH 10A_CBA_Mayport - MAMP - FINAL.pdf PDF
Att (L-13E) CDRL A005 Pearl Harbor_Inventory Report_2 Jul 2019.xls XLS spreadsheet
Att (5A) COMS Prem Time Request_2 Jul 2019.doc DOC document
Att (L-13G) CDRL A005 SWOSU Great Lakes_Inventory Report_2 Jul 2019.xlsx XLSX spreadsheet
ATCH 10A_WD 15-4539 (Rev.-9) Mayport.pdf PDF
ATCH 10E_WD 15-5689 (Rev.-9) Pearl Harbor.pdf PDF
Exhibit (A4) CDRL A004 Monthly Rpt (1423 and Annex only)_FF_DC COMS_23 Oct 2019.doc DOC document
Att (L-16C) San Diego Maint Sep 18 - Aug 19 dtd 7 Oct 19.pdf PDF
Att (L-13D) CDRL A005 OTC Newport_Inventory Report_2 Jul 2019.xls XLS spreadsheet
.Announcement_FinalRFP_11.20.2019.pdf PDF
Att (L-9B) Surf FF-DC Manpower Projection Workbook_7 Oct 2019.xlsx XLSX spreadsheet
Att (9A) Surf FF-DC Sect B_Price Evaluation Worksht_7 Oct 2019.xlsx XLSX spreadsheet
Att (1G) Appendix G_Surf FF-DC_SWOSU Great Lakes_1 Oct 2019.docx DOCX document
Att (1C) Appendix C_Surf FF-DC_San Diego_1 Oct 2019.docx DOCX document
Att (L-16B) Norfolk Maint Sep 18 - Aug 19 dtd 7 Oct 19.pdf PDF
Att (L-13A) CDRL A005 Mayport_Inventory Report_2 Jul 2019.xls XLS spreadsheet
ATCH 10D_WD 15-4089 (Rev.-11) Newport.pdf PDF
Att (5B) Premium Time Hours Log_15 Oct 2019.xls XLS spreadsheet
Att (L-16G) SWOSU Great Lakes Maint Sep 18 - Aug 19 dtd 7 Oct 19.pdf PDF
Att (L-18) Contractor Performance Assessment Questionnaire May 2016.msg.pdf PDF
Exhibit (A3) CDRL A003 Mob PSR w attach_FF_DC_23 Oct 2019.doc DOC document
Att (1B) Appendix B_Surf FF-DC_Norfolk_1 Oct 2019.docx DOCX document
Att (L-13B) CDRL A005 Norfolk_Inventory Report_2 Jul 2019.xls XLS spreadsheet
Show 40 more

Latest 50 of 87 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CDRL A004 ~ Monthly Report

(DI-MISC-81392)

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Month Ending: 31-Aug-19

Command: OTC Newport, RI 5-Sep-19

SECTION IV ~ MAINTENANCE ACTIONS

(1) CORRECTIVE MAINTENANCE ACTIONS

Corrective Maintenance Actions Current Month Previous Month

Fiscal Year To-Date

On-Site 11 22 79 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0

Totals: 11 22 79

(2) MEAN-TIME-TO-REPAIR (MTTR) and MEAN-TIME-BETWEEN-FAILURES (MTBF) (Cumulative by Fiscal Year)

Training System Major-Subsystem / Assembly

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours) 19F3A 1A3 (Pilot Failure) 9213/0700 9213/1000 3.00 9192/0700 3.00 1760.50

19F3A 0-1084 (Heater Block Leaking) 9213/0800 TBD 3.00 9219/0800 3.00 0.00

19F3A 2A4 (Pilot Failure) 9213/1200 9213/1300 1.00 9213/1300 1.00 0.00

19F3A 1-1228 (Thermocouple) 9218/0730 9218/1.5 1.50 9218/0730 1.50 0.00

19F3A 2A3 (Broken Burner Element) 9219/1300 9221/1400 49.00 9219/1300 49.00 0.00

19F3A 10A2 (Touch Screen) 9220/0700 9221/1400 30.50 9107/0730 30.50 1373.40

19F3A Manual Vent #5 (Fuses) 9225/0700 9225/0930 2.00 9225/0700 2.00 0.00

19F3A 0-1071 (Thermocouple) 9232/0730 9232/0930 2.00 9232/0730 2.00 0.00

19F3A HPAC (Sequencing Valve) 9233/0800 9233/1000 2.00 9212/0700 2.00 505.00

DCWT Pool Bumpers (Broken Mounting Stud) 9239/0730 9241/0930 2.00 9239/0730 2.00 0.00

19F3A 2A4 (Pilot Failure) 9242/0730 9242/0930 2.00 9213/1200 1.50 691.50

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

Report Date:

CDRL A004 - Monthly Report (DI-MISC-81392) Sect IV: Maintenance Actions (con't)

OTC Newport-Mthly Report CDRL A004 ~ Sect IV Mthly Report Maint Actions (con't) OTC Newport, RI

Contract: N61339-10-D-2002 TO 0002 Month Ending: 31-Aug-19 Command: OTC Newport, RI Report Date: 5-Sep-19

Section IV - Maintenance Actions (con't)

(3) REPAIR or REPLENISH

Seq No. *

Training System or

Equip S/N Description Failed Repairable or Repair Part

(Part # & Nomenclature) Date Repairable or Repart Part Failed

Date Repaired or Replenished

# Days to Repair or Replenish

Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOT replenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 069 19F3A 1 Compt 1 Pilot Failure Flame Rod 1-Aug-19 1-Aug-19 0 N/A

070 19F3A 1 Compt 2 Pilot Failure Water in Flame Rod Area. Possible impingement issue. 1-Aug-19 1-Aug-19 0 N/A

071 19F3A 1 Fryer/Hood Smoke Head Thermocouple 5-Aug-19 5-Aug-19 0 N/A 072 19F3A 1 North Side Quickpanel Replaced Quickpanel (IC754VFCTA) 8-Aug-19 9-Aug-19 0 N/A 073 19F3A 1 Compt 2 Burner Element Piping Replaced Burner and supply piping 6-Aug-19 7-Aug-19 0 N/A 074 19F3A 1 Compt 5 Man/Auto Vent Replaced 2 Fuses 12-Aug-19 12-Aug-19 0 N/A 075 19F3A 1 Sorage Locker Smoke Head Thermocouple 19-Aug-19 19-Aug-19 0 N/A

076 19F3A 1 Compt 2 Pilot Failure Water in Head. Possible impingment issue 29-Aug-19 29-Aug-19 0 N/A

077 19F3A 1 SCBA Compressor Sequencing Valve 21-Aug-19 21-Aug-19 0 N/A 078 DCWT 2 Pool Bumpers PORT/AFT Stud broken off. 27-Aug-19 29-Aug-19 0 N/A

079 19F3A 1 Compt 8 Smoke Head (Radar) Leaking heater block. 1-Aug-19 N/A 30 Awaiting block refurbishing at an outside contractor.

077 19F3A 1 FFT Week 26 (Th-F) PM's N/A N/A N/A N/A N/A 078 DCWT 2 DCWT Week 26 (Th-F) PM's N/A N/A N/A N/A N/A 079 19F3A 1 FFT Week 27 PM's N/A N/A N/A N/A N/A 080 DCWT 2 DCWT Week 27 PM's N/A N/A N/A N/A N/A 081 19F3A 1 FFT Week 28 PM's N/A N/A N/A N/A N/A 082 DCWT 2 DCWT Week 28 PM's N/A N/A N/A N/A N/A 083 19F3A 1 FFT Week 29 PM's N/A N/A N/A N/A N/A 084 DCWT 2 DCWT Week 29 PM's N/A N/A N/A N/A N/A 085 19F3A 1 FFT Week 30 PM's N/A N/A N/A N/A N/A 086 DCWT 2 DCWT Week 30 PM's N/A N/A N/A N/A N/A 087 19F3A 1 Filled and inspected 530 SCBA Bottles N/A N/A N/A N/A N/A 088 19F3A 1 Filled and inspected 32 AFFF Bottles N/A N/A N/A N/A N/A 089 19F3A 1 Filled and Inspected 32 CO2 Bottles N/A N/A N/A N/A N/A

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE

6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Month Ending: 31-Jul-19

Command: OTC Newport, RI 5-Aug-19

(1) CORRECTIVE MAINTENANCE ACTIONS

Corrective Maintenance Actions Current Month Previous Month

Fiscal Year To-Date

On-Site 22 9 68 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0

Totals: 22 9 68

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours)

19F3A CS 8-4 9184/0700 9184/1500 1.00 9184/0700 1.00 0.00

19F3A CS 6-1 9184/0700 9184/1500 1.00 9184/0700 1.00 0.00

Wet Trainer ES-4 9189/0700 9190/1500 1.00 9189/0700 1.00 0.00

Wet Trainer Plate Patch 9191/0700 9191/1500 1.00 9191/0700 1.00 0.00

19F3A 1A3 9192/0700 9192/1500 3.00 9066/1400 3.00 3017.00

19F3A CS 4-4 9192/0700 9192/1500 4.50 9192/0700 4.50 0.00

Wet Trainer Fan Room Hatch 9196/0700 9197/1500 25.00 9070/0800 25.00 3023.00

Wet Trainer Fan Roon Fans 9196/0700 9198/1500 48.00 9196/0700 48.00 0.00

Wet Trainer Cofferdam 9196/0700 9198/1500 49.00 9196/0700 49.00 0.00

19F3A AHU 6 9197/0700 9199/1500 49.50 9197/0700 49.50 0.00

19F3A Tank Farm Piping 9197/0700 9199/1500 49.50 9197/0700 49.50 0.00

Wet Trainer Flood Valve 9197/0700 9199/1500 46.00 9197/0700 46.00 0.00

19F3A EF 5 9197/0700 9199/1500 48.00 9197/0700 48.00 0.00

19F3A 2A1 9198/0700 9200/1500 47.50 9198/0700 47.50 0.00

Wet Trainer Bumpers 9199/0700 9200/1500 25.00 9199/0700 25.00 0.00

19F3A BASIN #1 9200/0700 9200/1500 1.00 9200/0700 1.00 0.00

Wet Trainer Bucket Patch 9204/0700 9204/1500 1.00 9204/0700 1.00 0.00

19F3A CS 8-9 9204/0700 9204/1500 1.00 9204/0700 1.00 0.00

19F3A 0-1051 9206/0700 9206/1500 3.00 9206/0700 3.00 0.00

Wet Trainer Aggitation Pump 9207/0700 9213/1500 0.50 9207/0700 0.50 0.00

Wet Trainer Plate Patch 9212/0700 9212/1500 1.50 9191/0700 1.20 504.00

19F3A HPAC 9212/0700 9214/1500 49.00 9212/0700 49.00 0.00

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

OTC Newport, RI

Contract: N61339-10-D-2002 TO 0002 Month Ending: 31-Jul-19 Command: OTC Newport, RI Report Date: 5-Aug-19

Section IV - Maintenance Actions (con't)

(3) REPAIR or REPLENISH

Seq No. *

Training System or

Equip S/N Description Failed Repairable or Repair Part

(Part # & Nomenclature) Date Repairable or Repart Part Failed

Date Repaired or Replenished

# Days to Repair or Replenish

Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOT replenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 047 19F3A 1 CRAWL SPACE 6 LAMP Replaced Bulb 3-Jul-19 3-Jul-19 0 N/A 048 19F3A 1 CRAWL SPACE 8 LAMP Replaced Bulb 3-Jul-19 3-Jul-19 0 N/A 049 DCWT 2 AFT/STBD BERTHING E-STOP Replaced Contact Block 8-Jul-19 9-Jul-19 0 N/A

050 DCWT 2 PLATE PATCH (WORN THREADS) Replaced Threaded Rod and Nut 10-Jul-19 10-Jul-19 0 N/A

051 19F3A 1 PILOT FAILURE 1A3 Inspected/Adjusted Fan, Adjusted Pilot 11-Jul-19 11-Jul-19 0 N/A 052 19F3A 1 CRAWL SPACE 4 LAMP Replaced Bulb socket and Bulb 11-Jul-19 11-Jul-19 0 N/A 053 DCWT 2 FAN ROOM Prepped and Painted Hatch Hinge Area 15-Jul-19 16-Jul-19 0 N/A

054 DCWT 2 FAN ROOM Prepped and Painted Fans and Duct Work 15-Jul-19 17-Jul-19 0 N/A

055 DCWT 2 COFFERDAM Prepped and Painted Various Areas 15-Jul-19 17-Jul-19 0 N/A 056 19F3A 1 TANK FARM PIPING Pepping/Painting/Replacing Lables 16-Jul-19 18-Jul-19 0 N/A

057 DCWT 2 FLOOD VALVE OPERATORS Prepped/Painted Reach-Rods/Operators 16-Jul-19 18-Jul-19 0 N/A

058 19F3A 1 VENTILATION Prepped/Painted Duct of AHU-6 16-Jul-19 18-Jul-19 0 N/A 059 19F3A 1 VENTILATION Prepped/Painted Top of EF 5 & 6 16-Jul-19 18-Jul-19 0 N/A 060 DCWT 2 BUMPERS (PORT SIDE) Replaced Broken Studs 18-Jul-19 19-Jul-19 0 N/A 061 19F3A 1 COMPT 2 SHAFT PROPS Welded a Patch Onto Shaft Boxes 18-Jul-19 19-Jul-19 0 N/A 062 19F3A 1 BASIN 1 Swept Basin 18-Jul-19 18-Jul-19 0 N/A 063 DCWT 2 AGGITATION PUMP Filter Cover Cracked 26-Jul-19 1-Aug-19 5 Awaiting Parts (Completed 8/1/19) 064 DCWT 2 BUCKET PATCH (Sharp Edges) Smoothed Out Sharp Edges 23-Jul-19 24-Jul-19 0 N/A 065 19F3A 1 CRAWL SPACE 8 LAMP Replaced Bulb 23-Jul-19 23-Jul-19 0 N/A 066 19F3A 1 WIRE BUNDLE SMOKE HEAD Replaced Thermocouple and Heater 25-Jul-19 25-Jul-19 0 N/A

067 DCWT 2 PLATE PATCH (Broken Anchor Lever) Replaced Pivot Ring 31-Jul-19 31-Jul-19 0 N/A

068 19F3A 1 SCBA COMPRESSOR (Suspected Issue

With automatic Drain Valve) Troublshot/Adjusted Settings/Tested-SAT 31-Jul-18 2-Aug-19 0

No Issues Found. Tested for two days (8/1 and 8/2)

064 19F3A 1 FFT Week 22 PM's N/A N/A N/A N/A N/A 065 DCWT 2 DCWT Week 22 PM's N/A N/A N/A N/A N/A 066 19F3A 1 FFT Week 23 PM's N/A N/A N/A N/A N/A 067 DCWT 2 DCWT Week 23 PM's N/A N/A N/A N/A N/A 068 19F3A 1 FFT Week 24 PM's N/A N/A N/A N/A N/A 069 DCWT 2 DCWT Week 24 PM's N/A N/A N/A N/A N/A 070 19F3A 1 FFT Week 25 PM's N/A N/A N/A N/A N/A 071 DCWT 2 DCWT Week 25 PM's N/A N/A N/A N/A N/A 072 19F3A 1 FFT Week 26 (M-W) PM's N/A N/A N/A N/A N/A 073 DCWT 2 DCWT Week 26 (M-W) PM's N/A N/A N/A N/A N/A

074 19F3A 1 Filled and inspected 394 SCBA Bottles N/A N/A N/A N/A N/A

075 19F3A 1 Filled and inspected 21 AFFF Bottles N/A N/A N/A N/A N/A 076 19F3A 1 Filled and Inspected 28 CO2 Bottles N/A N/A N/A N/A N/A

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE

6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Month Ending: 30-Jun-19

Command: OTC Newport, RI 8-Jul-19

(1) CORRECTIVE MAINTENANCE ACTIONS

Current Month Previous Month

Fiscal Year To-Date

9 14 46 0 0 0 0 0 0 0 0 0

9 14 46

System

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours) DCWT BL - 5 - Battle Lantern #5 9155/1000 9162/1000 1.00 9155/1000 1 0.00 DCWT BL #12 - Battle Lantern #12 9156/0900 9162/1000 0.50 9156/0900 0.5 0.00

19F3A 2A67 - Secondary Pressure

System 9162/0800 9162/1300 4.50

9162/0800

4.5 0.00

19F3A Lighting - Other - No Assy # 9168/1200 9168/1300 1.00 9168/1200 1 0.00

19F3A 5A35 - Compartmnetr 5 Halogen 9170/0900 9170/1000

1.00 9170/0900

1 0.00

19F3A 2A27 - Draw Sample Assy 9170/1304 9170/1500 1.50 9170/1304 1.5 0.00 19F3A Compt 9 9170/1400 9170/1500 1.00 9137/1400 1 792.00 19F3A 9a37 - Burner Control Cabinet 9176/0800 9176/0900 1.00 9176/0800 1 0.00

19F3A Bauer UNII/25 - SCMA

Compressor 9177/0700 9177/1100 3.00

9177/0700 3 0.00

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

OTC Newport, RI

Contract: N61339-10-D-2002 TO 0002 Month Ending: 30-Jun-19 Command: OTC Newport, RI Report Date: 8-Jul-19

Section IV - Maintenance Actions (con't)

(3) REPAIR or REPLENISH

Seq No. *

Training System or

Equip Description Failed Repairable or Repair Part

(Part # & Nomenclature) Date Repairable or Repart Part Failed

Date Repaired or Replenished

# Days to Repair or Replenish

Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOT replenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 038 19F3A Reduced Smoke Effluent Purged Air From Oil Piping 11-Jun-19 11-Jun-19 0 N/A 039 19F3A Crawl Space Lighting Switch Sticking - Cleaned/Lubricated 18-Jun-19 18-Jun-19 0 N/A 040 19F3A Pilot Prooved Failures in Compt 9 Adjusted Pilots 19-Jun-19 19-Jun-19 0 N/A 041 19F3A Compt 5 Halogen Replaced Bulb 19-Jun-19 19-Jun-19 0 N/A 042 19F3A Low Fire Switch Compt 9 Adjusted Low Fire Switch Linkage 25-Jun-19 25-Jun-19 0 N/A 043 DCWT Battle Lantern 12 Not Lighting Replaced Battery 5-Jun-19 11-Jun-19 6 N/A 044 DCWT Battle Lantern 5 Not Lighting Replaced Battery and Charging Unit 4-Jun-19 11-Jun-19 7 N/A

045 19F3A Propane Shutdown Compt 2 Inspected - No Issues Detected - Possible

Extinguishment Process 19-Jun-19 19-Jun-19 0 N/A

046 19F3A SCBA Compressor Filter Change/Clean 26-Jun-19 26-Jun-19 0 N/A

053 19F3A 1 FFT Week 18 PM's N/A N/A N/A N/A N/A 054 DCWT 2 DCWT Week 18 PM's N/A N/A N/A N/A N/A 055 19F3A 1 FFT Week 19 PM's N/A N/A N/A N/A N/A 056 DCWT 2 DCWT Week 19 PM's N/A N/A N/A N/A N/A 057 19F3A 1 FFT Week 20 PM's N/A N/A N/A N/A N/A 058 DCWT 2 DCWT Week 20 PM's N/A N/A N/A N/A N/A 059 19F3A 1 FFT Week 21 PM's N/A N/A N/A N/A N/A 060 DCWT 2 DCWT Week 21 PM's N/A N/A N/A N/A N/A

061 19F3A 1 Filled and inspected 565 SCBA

Bottles N/A N/A N/A N/A N/A

062 19F3A 1 Filled and inspected 28 AFFF

Bottles N/A N/A N/A N/A N/A

063 19F3A 1 Filled and Inspected 33 CO2 Bottles N/A N/A N/A N/A N/A

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Contractor: Month Ending: 31-May-19

Command: OTC Newport, RI Report Date: 5-Jun-19

(1) CORRECTIVE MAINTENANCE ACTIONS

Current Month Previous Month

Fiscal Year To-Date

14 8 37 0 0 0 0 0 0 0 0 0

14 8 37

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours)

DCWT MISC - TRAINER MISC 9122/0700 9127/1100 122.00 9091/0800 122.00 1031.50

19F3A 7-2 - Compartment 7 Maintenance

Light 9122/0800 9122/0900 1.00 9122/0800 1.00 0.00

19F3A Tank Farm CO2 - Tank Farm

Pneumatics 9122/1200 9122/1300 1.00 9122/1200 1.00 0.00

19F3A

TANK FARM - PNUEMATIC

CONTROL SYSTEM 9122/1300 9122/1500 2.00 9122/1300 2.00 0.00

19F3A Propane Tank #1 - Propane Tank

#1 9126/0700 9136/0900 2.00 9126/0700 2.00 0.00

19F3A 1A5 - AGENT SENSOR 9128/0800 9128/0900 1.00 9128/0800 1.00 0.00

19F3A

9A35 - BURNER CONTROL

CAB 9128/0900 9128/1030 1.50 9098/0800 1.50 721.00

19F3A

8A35 - COMP HALOGEN

LIGHT 9129/0800 9129/0900 1.00 9129/0800 1.00 0.00

19F3A 5-5 - Compartment 5 Maintenance

Light 9130/0800 9130/1100 3.00 9130/0800 3.00 0.00

19F3A

9A33 - BURNER CONTROL

CAB 9134/0800 9135/1100 27.00 9134/0800 27.00 0.00

19F3A EF 6 - TRAINER EXH FAN 9137/1300 9150/0900 308.00 9127/1300 308.00 0.00

19F3A COMPT 9 - Compartment 9 9137/1400 9150/1000 308.00 9137/1400 308.00 0.00

19F3A 4A6 - BURNER CONTROL CAB 9143/0700 9143/0800 1.00 9143/0700 1.00 0.00

19F3A Compartment Dampers - Compartment Dampers 9143/0800 9143/0900 1.00 9143/0800 1.00 0.00

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

OTC Newport, RI

Contract: N61339-10-D-2002 TO 0002 Month Ending: 31-May-19 Command: OTC Newport, RI Report Date: 5-Jun-19

Section IV - Maintenance Actions (con't)

(3) REPAIR or REPLENISH

Seq No. *

Training System or

Equip Description Failed Repairable or Repair Part

(Part # & Nomenclature) Date Repairable or Repart Part Failed

Date Repaired or Replenished

# Days to Repair or Replenish

Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOT replenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 024 DCWT 2 DCWT DC Central Window Replaced Window 2-May-19 7-May-19 5 N/A 025 19F3A 1 Tank Farm Pneumatics Repaired Tubing Leak 2-May-19 2-May-19 0 N/A 026 19F3A 1 Pneumatic Control Replaced Pneumatic Actuator 2-May-19 2-May-19 0 N/A 027 19F3A 1 Compartment 7 Maint. Light Replaced Bulb 2-May-19 2-May-19 0 N/A 028 19F3A 1 Propane Tank #1 Replaced Valve Packing 6-May-19 6-May-19 0 N/A 029 19F3A 1 Compartment 1 Agent Detector Replaced Water Sensor 8-May-19 8-May-19 0 N/A 030 19F3A 1 9A35 - Burner Control Cabinet Adjusted Valve Linkage 8-May-19 8-May-19 0 N/A 031 19F3A 1 8A35 - Compartment Lighting Replaced Halogen Bulb 9-May-19 9-May-19 0 N/A 032 19F3A 1 Compartment 5 Maint. Light Replaced Socket and Bulb 10-May-19 10-May-19 0 N/A 033 19F3A 1 9A33 - Burner Control Cabinet Replaced 4 Low Fire Switches 14-May-19 15-May-19 1 N/A 034 19F3A 1 Exhaust Fan 6 Replaced Soft Start Power Supply 17-May-19 30-May-19 13 N/A 035 19F3A 1 4A6 - Burner Control Cabinet Replaced Flame Safeguard 23-May-19 23-May-19 0 Ordered (5/24), Received (6/4) 036 19F3A 1 Compartment Damper Motors Replaced Indicator Bulbs 23-May-19 23-May-19 0 N/A

037 19F3A 1 Compartment 9 Isolated Front 3 Burners while EF-6 was OOC. RTS, Tested: SAT. 17-May-19 30-May-19

Done With COR and Staff Approval

040 19F3A 1 FFT Week 13 (W-F) PM's N/A N/A N/A N/A N/A 041 DCWT 2 DCWT Week 13 (W-F) PM's N/A N/A N/A N/A N/A 042 19F3A 1 FFT Week 14 PM's N/A N/A N/A N/A N/A 043 DCWT 2 DCWT Week 14 PM's N/A N/A N/A N/A N/A 044 19F3A 1 FFT Week 15 PM's N/A N/A N/A N/A N/A 045 DCWT 2 DCWT Week 15 PM's N/A N/A N/A N/A N/A 046 19F3A 1 FFT Week 16 PM's N/A N/A N/A N/A N/A 047 DCWT 2 DCWT Week 16 PM's N/A N/A N/A N/A N/A 048 19F3A 1 FFT Week 17 PM's N/A N/A N/A N/A N/A 049 DCWT 2 DCWT Week 17 PM's N/A N/A N/A N/A N/A

050 19F3A 1 Filled and inspected 526 SCBA

Bottles N/A N/A N/A N/A N/A

051 19F3A 1 Filled and inspected 35 AFFF

Bottles N/A N/A N/A N/A N/A

052 19F3A 1 Filled and Inspected 27 CO2 Bottles N/A N/A N/A N/A

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Month Ending: 30-Apr-19

Command: OTC Newport, RI Report Date: 2-May-19

(1) CORRECTIVE MAINTENANCE ACTIONS

Current Month Previous Month

Fiscal Year To-Date

8 9 23 0 0 0 0 0 0 0 0 0

8 9 23

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours) Wet Trainer Misc-Trainer Misc 9091/0800 9094/0930 1.50 9036/0800 1.5 1320.00

19F3A 7-3, Compt 7 Maint Light 9095/0800 9095/1100 3.00 9095/0800 3 0.00 19F3A 9A35 9098/0800 9099/1300 29.00 9098/0800 29 0.00 19F3A VP1 - Propane Vaporizer 9101/0800 9102/1300 5.00 9101/0800 5 0.00 19F3A 10A2 - IOS Console North 9106/0800 9106/0900 1.50 9106/0800 1.5 0.00 19F3A 10A2 - IOS Console North 9107/0730 9107/0900 1.00 9106/0800 1.2 0.00 19F3A UH-13 - Heater Unit 9113/0900 9115/0900 1.00 9113/0900 1 0.00 19F3A UH-16 - Unit Heater #16 9113/0900 9115/1300 1.00 9113/0900 1 0.00

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

OTC Newport, RI

Contract: N61339-10-D-2002 TO 0002 Month Ending: 30-Apr-19 Command: OTC Newport, RI Report Date: 2-May-19

Section IV - Maintenance Actions (con't)

(3) REPAIR or REPLENISH

Seq No. *

Training System or

Equip Description Failed Repairable or Repair Part

(Part # & Nomenclature) Date Repairable or Repart Part Failed

Date Repaired or Replenished

# Days to Repair or Replenish

Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOT replenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 016 19F3A Light out under Compt. 7. Replaced Light 5-Apr-19 5-Apr-19 0 N/A 017 DCWT Start/Stop Fan Room Controller Painted controller 1-Apr-19 4-Apr-19 0 N/A 018 19F3A Low Fire Switches to 9A35 Replaced Low Fire Switches 8-Apr-19 9-Apr-19 0 N/A 019 19F3A 1MC/SPT Switch on 10A2 Replaced Switch 16-Apr-19 16-Apr-19 0 N/A 020 19F3A 1MC Amplifier Fuse Replaced Fuse 17-Apr-19 17-Apr-19 0 N/A 021 19F3A Unit Heater #13 Adjusted On/Off Switch 23-Apr-19 25-Apr-19 0 N/A 022 19F3A Unit Heater #16 Replaced Fan Blade 23-Apr-19 25-Apr-19 0 N/A

023 19F3A Gastket leak at Burner of Vaporizer

#1. Will Replace Gasket 11-Apr-19 TBD 0 Vaporizers are in in Lay-up for the Summer

027 19F3A 1 FFT Week 9 PM's N/A N/A N/A N/A N/A 028 DCWT 2 DCWT Week 9 PM's N/A N/A N/A N/A N/A 029 19F3A 1 FFT Week 10 PM's N/A N/A N/A N/A N/A 030 DCWT 2 DCWT Week 10 PM's N/A N/A N/A N/A N/A 031 19F3A 1 FFT Week 11 PM's N/A N/A N/A N/A N/A 032 DCWT 2 DCWT Week 11 PM's N/A N/A N/A N/A N/A 033 19F3A 1 FFT Week 12 PM's N/A N/A N/A N/A N/A 034 DCWT 2 DCWT Week 12 PM's N/A N/A N/A N/A N/A 035 19F3A 1 FFT Week 13 (M-T) PM's N/A N/A N/A N/A N/A 036 DCWT 2 DCWT Week 13 (M-T) PM's N/A N/A N/A N/A N/A

037 19F3A 1 Filled and inspected 374 SCBA

Bottles N/A N/A N/A N/A N/A

038 19F3A 1 Filled and inspected 32 AFFF

Bottles N/A N/A N/A N/A N/A

039 19F3A 1 Filled and Inspected 32 CO2 Bottles N/A N/A N/A N/A

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Month Ending: 31-Mar-19

Command: OTC Newport, RI Report Date: 2-Apr-19

(1) CORRECTIVE MAINTENANCE ACTIONS

Corrective Maintenance Actions Current Month Previous Month

Fiscal Year To-Date

On-Site 9 6 15 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0

Totals: 9 6 15

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours) 19F3A 1A2 (Wire Insulation) 9066/1300 9066/1400 1.00 9066/1300 1 0.00 19F3A 1A3 (Wire Insulation) 9066/1400 9066/1500 1.00 9066/1400 1 0.00 19F3A 9A38 (Low Fire Switches) 9070/0700 9070/1500 8.00 9070/0700 8 0.00

Wet Trainer Fan Room Hatch Gasket 9070/0800 9070/1000 2.00 9070/0800 2 0.00 Wet Trainer BL-8 (Battle Lantern Battery) 9079/1300 9080/0900 0.50 9079/1300 0.5 0.00 Wet Trainer BL-4 (Battle Lantern Battery) 9079/1300 9080/0900 0.50 9079/1300 0.5 0.00

19F3A 5A6 (Adjsuted Linkages) 9084/1300 9084/1500 2.00 9084/1300 2 0.00 19F3A North Side Maint. Lights 9085/0800 9085/1400 1.00 9085/0800 1 0.00 19F3A Compt 6 Maint Light Out 9088/0800 9088/1100 3.00 9088/0800 3 0.00

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

OTC Newport, RI

Contract: N61339-10-D-2002 TO 0002 Month Ending: 31-Mar-19 Command: OTC Newport, RI Report Date: 2-Apr-19

Section IV - Maintenance Actions (con't)

(3) REPAIR or REPLENISH

Seq No. *

Training System or

Equip S/N Description Failed Repairable or Repair Part

(Part # & Nomenclature) Date Repairable or Repart Part Failed

Date Repaired or Replenished

# Days to Repair or Replenish

Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOT replenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 007 19F3A 1 1A2 Burner Control Ignition Cable Insulation 7-Mar-19 7-Mar-19 0 N/A 008 19F3A 1 1A3 Burner Control Ignition Cable Insulation 7-Mar-19 7-Mar-19 0 N/A 009 19F3A 1 Compartment 9 Burner B1 3 Low Fire Switches 11-Mar-19 11-Mar-19 0 N/A 010 19F3A 1 5A6 Burner Control Adjusted Actuator Arms 25-Mar-19 25-Mar-19 0 N/A 011 19F3A 1 Maintenance Light Compt 6 Replaced Socket and Bulb 29-Mar-19 29-Mar-19 0 N/A 012 DCWT 2 Fan Room Hatch Gasket Replaced Gasket 11-Mar-19 11-Mar-19 0 N/A 013 DCWT 2 Battle Lantern #8 Replaced Battery 20-Mar-19 21-Mar-19 0 N/A 014 DCWT 2 Battle Lantern #4 Replaced Battery 20-Mar-19 21-Mar-19 0 N/A 015 19F3A 1 North Side Ladder Maint Lights Upper Level Switch Was Off 26-Mar-19 26-Mar-19 0 N/A

014 19F3A 1 FFT Week 4 (F) N/A N/A N/A N/A N/A 015 DCWT 2 DCWT Week 4 (F) N/A N/A N/A N/A N/A 016 19F3A 1 FFT Week 5 PM's N/A N/A N/A N/A N/A 017 DCWT 2 DCWT Week 5 PM's N/A N/A N/A N/A N/A 018 19F3A 1 FFT Week 6 PM's N/A N/A N/A N/A N/A 019 DCWT 2 DCWT Week 6 PM's N/A N/A N/A N/A N/A 020 19F3A 1 FFT Week 7 PM's N/A N/A N/A N/A N/A 021 DCWT 2 DCWT Week 7 PM's N/A N/A N/A N/A N/A 022 19F3A 1 FFT Week 8 PM's N/A N/A N/A N/A N/A 023 DCWT 2 DCWT Week 8 PM's N/A N/A N/A N/A N/A

024 19F3A 1 Filled and inspected 442 SCBA

Bottles N/A N/A N/A N/A N/A

025 19F3A 1 Filled and inspected 50 CO2 Bottles N/A N/A N/A N/A N/A

026 19F3A 1 Filled and Inspected 37 AFFF

Bottles N/A N/A N/A N/A

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Contractor: Month Ending: 28-Feb-19

Command: OTC Newport, RI Report Date: 4-Mar-19

(1) CORRECTIVE MAINTENANCE ACTIONS

Corrective Maintenance Actions Current Month Previous Month

Fiscal Year To-Date

On-Site 6 5 6 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0

Totals: 6 5 6

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours) 19F3A PWP1 - Process Water Pump 9032/1000 9057/1400 363.00 9032/1000 363 0.00 DCWT Misc - Trainer Misc 9036/0800 9036/0900 1.00 9036/0800 1 0.00

DCWT #3 - P-100 9038/1000 9039/1030 3.00 9038/1000 3 0.00

DCWT #3 - P-100 9042/0800 9042/0930 1.00 9038/1000 2 94.00

19F3A Compartment 8 Vent Duct 9043/0900 9051/0800 0.50 9043/0900 0.5 0.00 19F3A Compartment 2 Vent Duct 9043/0900 9051/0830 0.50 9043/0900 0.5 0.00

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

OTC Newport, RI

Contract: N61339-10-D-2002 TO 0002 Month Ending: 28-Feb-19 Command: OTC Newport, RI Report Date: 4-Mar-19

Section IV - Maintenance Actions (con't)

(3) REPAIR or REPLENISH

Seq No. *

Training System or

Equip S/N Description Failed Repairable or Repair Part

(Part # & Nomenclature) Date Repairable or Repart Part Failed

Date Repaired or Replenished

# Days to Repair or Replenish

Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOT replenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 001 DCWT 2

P100's move during start-up and operation Secured P100's to the deck. 5-Feb-19 2-Feb-10 0 N/A

002 DCWT 2 P100 #3 Frame Broken Replaced Frame 6-Feb-19 7-Feb-19 0 N/A 003 DCWT 2 P100 #3 Oil Change Changed Oil, Replaced Filter 11-Feb-19 11-Feb-19 0 N/A

004 19F3A 1 Process Water Pump #1 Pump Bearings and Shaft Sleeve* 11-Feb-19 26-Feb-19 15

* A crack in a Shaft Sleeve was found after disassmbly to replace the bearings. Unforseen issue, and not inspectable without dissasembly.

005 19F3A 1 Compartment 8 Duct Broken inspection door handle 12-Feb-19 22-Feb-19 8 N/A 006 19F3A 1 Compartment 2 Duct Sticking inspection door latch. 12-Feb-19 22-Feb-19 8 N/A

001 19F3A 1 FFT Week 49 (F) N/A N/A N/A N/A N/A 002 DCWT 2 DCWT Week 49 (F) N/A N/A N/A N/A N/A 003 19F3A 1 FFT Week 1 PM's N/A N/A N/A N/A N/A 004 DCWT 2 DCWT Week 1 PM's N/A N/A N/A N/A N/A 005 19F3A 1 FFT Week 2 PM's N/A N/A N/A N/A N/A 006 DCWT 2 DCWT Week 2 PM's N/A N/A N/A N/A N/A 007 19F3A 1 FFT Week 3 PM's N/A N/A N/A N/A N/A 008 DCWT 2 DCWT Week 3 PM's N/A N/A N/A N/A N/A 009 19F3A 1 FFT Week 4 (M- Th) PM's N/A N/A N/A N/A N/A 010 DCWT 2 DCWT Week 4 (M-Th) PM's N/A N/A N/A N/A N/A

011 19F3A 1 Filled and inspected 244 SCBA

Bottles N/A N/A N/A N/A N/A

012 19F3A 1 Filled and inspected 20 CO2 Bottles N/A N/A N/A N/A N/A

013 19F3A 1 Filled and Inspected 20 AFFF

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.

Note: PM Week Numbers have been redesignated to better associate with the Contract Year schedule. For instance Week 50 is now week 1.

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Month Ending: 31-Jan-19

Command: OTC Newport, RI Report Date: 4-Feb-19

(1) CORRECTIVE MAINTENANCE ACTIONS

Corrective Maintenance Actions Current Month Previous Month

Fiscal Year To-Date

On-Site 5 14 133 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0

Totals: 5 14 133

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours) DCWT Misc. - Paint Preservation 9002/0700 9015/1530 319.50 9002/0700 319.5 739.20 DCWT Misc. - DC Central Welding 9004/0700 9015/1530 266.00 9002/0700 292.8 624.00 19F3A Maint Lighting 1-3 9008/0800 9008/0900 1.00 9008/0800 1 0.00 DCWT Misc. - Store Room Door 9023/0800 9024/0900 1.00 9004/0700 195.5 600.10 19F3A Maint Lighting 4-11 9024/0800 9024/0900 1.00 9024/0800 1 0.00

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

OTC Newport, RI

Contract: N61339-10-D-2002 TO 0002 Month Ending: 31-Jan-19 Command: OTC Newport, RI Report Date: 4-Feb-19

Section IV - Maintenance Actions (con't)

(3) REPAIR or REPLENISH

Seq No. *

Training System or

Equip S/N Description Failed Repairable or Repair Part

(Part # & Nomenclature) Date Repairable or Repart Part Failed

Date Repaired or Replenished

# Days to Repair or Replenish

Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOT replenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 127 19F3A 1 Maint Lamp out under Compt 1 Replaced Bulb 8-Jan-19 8-Jan-19 0 N/A

128 DCWT 2 Paint Preservation fo DCWT

Perpped and Painted Cofferdam, Store Room, Bearthing, Main Deck, DC

Central, Fan Room, Pump Room and Repair Locker. 2-Jan-19 15-Jan-19 13

N/A

129 DCWT 2 Welding Repair in DC Central Contractor patched and reinforced hole discovered in DC Central 4-Jan-19 15-Jan-19 11 N/A

130 DCWT 2

Dog to Store Room door need adjusting Tightened dogs. 23-Jan-19 24-Jan-19 0 N/A

131 19F3A 1 Maint Lamp out between Compts 3 and 4 Replaced Bulb 24-Jan-19 24-Jan-19 0 N/A

112 19F3A 1 FFT Week 45 (T-F) PM's N/A N/A N/A N/A N/A 113 DCWT 2 DCWT Week 45 (T-F) PM's N/A N/A N/A N/A N/A 114 19F3A 1 FFT Week 46 PM's N/A N/A N/A N/A N/A 115 DCWT 2 DCWT Week 46 PM's N/A N/A N/A N/A N/A 116 19F3A 1 FFT Week 47 PM's N/A N/A N/A N/A N/A 117 DCWT 2 DCWT Week 47 PM's N/A N/A N/A N/A N/A 118 19F3A 1 FFT Week 48 PM's N/A N/A N/A N/A N/A 119 DCWT 2 DCWT Week 48 PM's N/A N/A N/A N/A N/A 120 19F3A 1 FFT Week 49 (M-Th) PM's N/A N/A N/A N/A N/A 121 DCWT 1 DCWT Week 49 (M-Th) PM's N/A N/A N/A N/A N/A

122 19F3A 1 Filled and inspected 272 SCBA

Bottles N/A N/A N/A N/A N/A

123 19F3A 1 Filled and inspected 29 CO2 Bottles N/A N/A N/A N/A N/A

124 19F3A 1 Filled and Inspected 28 AFFF

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Month Ending: 31-Dec-18

Command: OTC Newport, RI Report Date: 3-Jan-19

(1) CORRECTIVE MAINTENANCE ACTIONS

Corrective Maintenance Actions Current Month Previous Month

Fiscal Year To-Date

On-Site 13 11 127 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0

Totals: 13 11 127

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours)

19F3A ECC - Environment Control

Console 8337/0730 8337/1400 6.50

8306/0800

6.5 560.30

DCWT BP #1 - Bucket Patch #1 8338/0730 8338/0830 1.00 8338/0730 1 0.00 DCWT BP #2 - Bucket Patch #2 8338/0830 8338/0930 1.00 8338/0830 1 0.00

19F3A M.Vent. #4 - Manual Vent

Compartment 4 8339/0800 8339/1330 5.50

8339/0800

5.5 0.00

19F3A

PWP1 - PROCESS WATER

PUMP 8346/0800 8346/1430

6.50

8325/1000

6.5 430.30

19F3A

7A35 - COMPARTMENT

LIGHTING ASSY 8346/1200 8346/1300

1.00

8346/1200 1 0.00

19F3A

LIGHTING - OTHER - NO

ASSY # 8354/1000 8354/1100

1.00

8206/0800 1 1847.50

19F3A CS 3-6 - Crawl Space Lamp 3-6 8358/0730 8358/1030

3.00 8358/0730

3 0.00

19F3A MISC - TRAINER MISC 8360/0730 8365/0700 54.00 8229/0730 54 1176.20

DCWT

Steam Piping L/L - Steam Piping

Lower Level 8360/0800 8362/1000 50.00

8360/0800 50 0.00

19F3A

9A35 - BURNER CONTROL

CAB 8360/0800 8360/1430

6.50

8317/0900

6.5 1031.00

19F3A 9A38 - BURNER CONTROL

CAB 8360/0800 8361/1430

6.50 8361/0800

6.5 0.00

19F3A

9A37 - BURNER CONTROL

CAB 8362/0800 8362/1430

6.50

8362/0800

6.5 0.00

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

OTC Newport, RI

Contract: N61339-10-D-2002 TO 0002 Month Ending: 31-Dec-18 Command: OTC Newport, RI Report Date: 3-Jan-19

Section IV - Maintenance Actions (con't)

(3) REPAIR or REPLENISH

Seq No. *

Training System or

Equip S/N Description Failed Repairable or Repair Part

(Part # & Nomenclature) Date Repairable or Repart Part Failed

Date Repaired or Replenished

# Days to Repair or Replenish

Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOT replenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 114 19F3A 1 Manual Vent Indicators Checked fuses, Replaced bulbs, Adjusted setpoints. 3-Dec-18 3-Dec-18 0 N/A

115 DCWT 2 Bucket Patch #1 Replaced Bucket 4-Dec-18 4-Dec-18 0 N/A 116 DCWT 2 Bucket Patch #2 Replaced Bucket 4-Dec-18 4-Dec-18 0 N/A

117 19F3A 1 Manual Vent Compt. 4 PLC Module Replaced 5-Dec-18 5-Dec-18 0 Ordered IC694MDL752 for inventory replenishment.

118 19F3A 1 Compt 7/8 Halogen Lamp Halogen Bulb (A-A-1967) 12-Dec-18 12-Dec-18 0 N/A

119 19F3A 1 Process Water Pump #1 Outside Contractor Rebuilt Motor 12-Dec-18 12-Dec-18 0 Noise reduced but awaiting quote for pump rebuild.

120 19F3A 1 Halogen lights out for

Compartments 6 and 7. Tripped breaker. Reset. 20-Dec-18 20-Dec-18 0 COMS will continue to monitor to determine why breaker tripped.

121 19F3A 1 Compartment 3 Crawl Space light. Replaced socket and bulb. 24-Dec-18 24-Dec-18 0 N/A

122 19F3A 1 Lower Level Steam Piping pipe hangers Swapped, prepped and painted various pipe hangers. 26-Dec-18 28-Dec-18 2

Paint/Preservation of L/L steam pipe hangers during stand-down. Annotated as Scheduled

Maintenance.

123 DCWT 2 DCWT Cofferdam Prepping Cofferdam for Painting 26-Dec-18 28-Dec-18 2

Paint/Preservation work for Cofferdam and Non-Skid. Annotated as Scheduled

Maintenance.

124 19F3A 1 Compartment 9 random flare-ups.

Adjusted brakets, linkages, cleaned switches. (9A35). 26-Dec-18 26-Dec-18 0 N/A

125 19F3A 1 Compartment 9 random flare-ups.

Adjusted brakets, linkages, cleaned switches. (9A35). 27-Dec-18 27-Dec-18 0 N/A

126 19F3A 1 Compartment 9 random flare-ups.

Adjusted brakets, linkages, cleaned switches. (9A35). 28-Dec-18 28-Dec-18 0 N/A

100 19F3A 1 FFT Week 41 PM's N/A N/A N/A N/A N/A 101 DCWT 2 DCWT Week 41 PM's N/A N/A N/A N/A N/A 102 19F3A 1 FFT Week 42 PM's N/A N/A N/A N/A N/A 103 DCWT 2 DCWT Week 42 PM's N/A N/A N/A N/A N/A 104 19F3A 1 FFT Week 43 PM's N/A N/A N/A N/A N/A 105 DCWT 2 DCWT Week 43 PM's N/A N/A N/A N/A N/A 106 19F3A 1 FFT Week 44 PM's N/A N/A N/A N/A N/A 107 DCWT 2 DCWT Week 44 PM's N/A N/A N/A N/A N/A 108 19F3A 1 FFT Week 45 (M) PM's N/A N/A N/A N/A N/A 109 DCWT 2 DCWT Week 45 (M) PM's N/A N/A N/A N/A N/A

110 19F3A 1 Filled and inspected 143 SCBA

Bottles N/A N/A N/A N/A N/A

111 19F3A 1 Filled and inspected 15 CO2 Bottles N/A N/A N/A N/A

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Month Ending: 30-Nov-18

Command: OTC Newport, RI Report Date: 4-Dec-18

(1) CORRECTIVE MAINTENANCE ACTIONS

Corrective Maintenance Actions Current Month Previous Month

Fiscal Year To-Date

On-Site 11 12 114 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0

Totals: 11 12 114

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours)

19F3A ECC (18-099 {2}) 8306/0800 8306/0900 1.0 8290/1500 1 377.0

19F3A UH-9 (18-104) 8309/0730 TBD 54.4 8309/0730 54.5 0.0

19F3A PWP 1 (18-105) 8309/0900 8131/0800 92.0 8292/1300 92 404.0

19F3A 2A5 (18-108) 8309/0900 8317/1000 164.5 8225/0700 164.5 1487.3 19F3A 9A33 (18-106) 8137/0800 8317/0900 1.0 8317/0800 1 0.0 19F3A 9A35 (18-107) 8317/0900 8317/1000 1.0 8317/0900 1 0.0 DCWT Pool (18-113) 8318/0800 8331/0800 288.0 8318/0800 288 0.0

DCWT BL - 8 (18-110) 8324/0800 8331/0830 0.5 8324/0800 0.5 0.0

DCWT BL - 4 (18-109) 8324/0800 8331/0900 0.5 8324/0800 0.5 0.0

19F3A PWP 1 (18-112) 8325/1000 TBD 31.0 8309/0900 61.50 394.5

19F3A Laptop - ISE (18-111) 8331/0900 8331/1100 0.5 8331/0900 0.5 0.0

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

NOTE: 18-111 Not counted on COMS hours.

OTC Newport, RI

Contract: N61339-10-D-2002 TO 0002 Month Ending: 30-Nov-18 Command: OTC Newport, RI Report Date: 4-Dec-18

Section IV - Maintenance Actions (con't)

(3) REPAIR or REPLENISH

Seq No. *

Training System or

Equip S/N Description Failed Repairable or Repair Part

(Part # & Nomenclature) Date Repairable or Repart Part Failed

Date Repaired or Replenished

# Days to Repair or Replenish

Remarks: If Repairable NOT repaired or replenished w/in 30 days; or Repair Part NOT replenished w/in 30 days, provide COR plan of action to return Repairables or Repair Parts to MSP in an RFI condition. (Use additional sheets to provide this information, 099 (2) 19F3A 1 Environment Control Console Adjusted/Cleaned solenoid Valve 17-Oct-18 2-Nov-18 16 Leak fixed. No Training was affected.

103 DCWT 2 Drain Valve / Pool Leak Suspected leak at Drain Valve determined to be hole in "Dry" sump. 30-Oct-18 31-Oct-18 28 Issue turned over to NAVFAC (See Seq. No.

113)

104 19F3A 1 Unit Heater #9 Leaking

Replaced Condensate (outlet) valve, but Steam (inlet) valve is leaking by as well.

Can not replace heater until inlet valve is replaced. 5-Nov-18 TBD 25+

Must have another spell of warm weather to isolate steam to trainer to replacee inlet valve and then unit heater.

105 19F3A Process Water Pump #1 Unusual noise heard. Suspected motor to pump coupling insert. 5-Nov-18 9-Nov-18 4 Coupling insert replaced. Elimitated some noise but not gone completely.

106 19F3A 9A33 - Low Fire Switch Adjusted actuator arm. 13-Nov-18 13-Nov-18 0 N/A 107 19F3A 9A35 - Low Fire Switch Adjusted actuator arm. 13-Nov-18 13-Nov-18 0 N/A

108 19F3A 2A5 Pilot Gas Pipe Pilot gas pipe replaced. 7-Nov-18 13-Nov-18 6

Piplot gas pipe was looking rusted. Replaced pipe. Old pipe was OK but environment limits proper paint/preservation.

109 DCWT Battle Lantern #8 Replaced Battery 20-Nov-18 27-Nov-18 7 Delay due to Training 110 DCWT Battle Lantern #4 Replaced Battery 20-Nov-18 27-Nov-18 7 Delay due to Training 111 19F3A Laptop ISE Updated Virus Protection 27-Nov-18 27-Nov-18 0 Not added to COMS Mainteance Hours

112 19F3A Process Water Pump #1 Outside vendor recommended a motor rebuild. 21-Nov-18 TBD 9+ Purchase Request created for motor rebuild.

113 DCWT Pool Leak

Identified a hole in the "Dry" sump causing the water loss. Plugged hole, refilled pool. No futher water loss detected after two weeks. 14-Nov-18 27-Nov-18 13

NAVFAC inspected drain valve (from Seq.

No. 103) and found no leakage past valve.

087 19F3A 1 FFT Week 36 (Th-F) PM's N/A N/A N/A N/A N/A 088 DCWT 2 DCWT Week 36 (Th-F) PM's N/A N/A N/A N/A N/A 089 19F3A 1 FFT Week 37 PM's N/A N/A N/A N/A N/A 090 DCWT 2 DCWT Week 37 PM's N/A N/A N/A N/A N/A 091 19F3A 1 FFT Week 38 PM's N/A N/A N/A N/A N/A 092 DCWT 2 DCWT Week 38 PM's N/A N/A N/A N/A N/A 093 19F3A 1 FFT Week 39 PM's N/A N/A N/A N/A N/A 094 DCWT 2 DCWT Week 39 PM's N/A N/A N/A N/A N/A 095 19F3A 1 FFT Week 40 PM's N/A N/A N/A N/A N/A 096 DCWT 2 DCWT Week 40 PM's N/A N/A N/A N/A N/A

097 19F3A 1 Filled and inspected 321 SCBA

Bottles N/A N/A N/A N/A N/A

098 19F3A 1 Filled and inspected 29 CO2 Bottles N/A N/A N/A N/A N/A

099 19F3A 1 Filled and inspected 37 AFFF

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTRATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO THE COMMANDING OFFICER, NAVAL AIR WARFARE CENTER, TRAINING SYSTEMS DIVISION, (CODE 6643), 12350 RESEARCH PARKWAY, ORLANDO, FL 32826-3275.

* Sequence Number: = Number failed Repairable or Repair Part (R/RP) sequentially. R/RPs not returned to the MSP in an RFI condition at the end of the month are carried over to the following month, with its appropriate sequence number for tracking purposes. R/RPs shown repaired or replenished and returned to the MSP in an RFI condition during this report period will drop from the next month's report.

Section IV - MAINTENANCE ACTIONS

OTC Newport Mthly Report CDRL AOO4 ~ Mthly Sect IV - Maintenance Actions OTC Newport, RI

Contract: N61339-10-D-2002 Task 0002 Month Ending: 31-Oct-18

Command: OTC Newport, RI Report Date: 1-Nov-18

(1) CORRECTIVE MAINTENANCE ACTIONS

Corrective Maintenance Actions Current Month Previous Month

Fiscal Year To-Date

On-Site 12 19 103 Corporate 0 0 0 Vendor 0 0 0 Others 0 0 0

Totals: 12 19 103

Julian Date & Time Failed

Julian Date & Time

Restored

Time to Repair (Hours)

Julian Date/Time Last Failure

Average MTTR Todate

(Hours)

Average MTBF Todate

(Hours) 19F3A 2A37 - Halogen Light 8274/0830 8274/0930 1.0 8274/0830 1 0.0 DCWT Flood Valve - Broken Coupling 8275/1200 8276/0930 2.0 8275/1200 2.0 0.0 19F3A 1A9 - Pilot Failure 8275/1245 8275/1255 0.2 8275/1245 0.2 0.0 19F3A Inactive Bunk -Paint, Compt 6 8276/0900 8282/0900 141.0 8276/0900 141 0.0

19F3A

U/L Ventilation Inspection Hatches 8279/0900 8282/100 98.0 8276/0900 98 0.0

19F3A 2A3 - Propane Supply Pipe 8278/0900 8278/1300 3.5 8106/0730 3.5 2517.3

19F3A

Environment Control Console - Pnuematic Leak 8290/1500 N/A 72.0 8290/1500 72 0.0

19F3A

Process Water Pump 1 Packing Leak 8292/1000 9292/1400 1.0 8292/1300 1 0.0

DCWT Clorine Monitor Flow Sensor Leak 8295/0800 8296/1100 0.5 8295/0800 0.5 0.0 19F3A 10A3 Cooling Fan Replaced 8297/0800 8279/1000 2.0 8297/0800 2.00 0.0 19F3A 2A13 Pilot Failure 8304/0600 8304/0700 0.5 8247/0705 0.5 1271.3 DCWT Drain Valve 8303/0700 8304/1100 26.0 8308/0700 26.0 0.0

DISTRIBUTION B: DISTRIBUTION IS AUTHORIZED TO- U.S. GOVERNMENT AGENCIES ONLY, ADMINISTATIVE OR OPERATIONAL USE, AS DETERMINED 27 MAY 2009.