This document provides details for a federal solicitation seeking renovations and repairs at Naval Submarine Base New London. The solicitation number is N4008523R2530 and is being issued by the Department of the Navy Naval Facilities Engineering Command. Interested parties are instructed to review the solicitation and all accompanying attachments for requirements regarding the scope of work. Relevant repairs and renovations are to be completed at the specified military base as part of the contract award. The response deadline and anticipated award date are not stated.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIFICATION
ADDITIONAL COMPULSORY DOCUMENTATION
Permanent Party Repairs BQ455 Project Number:1632260
At
NAVAL SUBASE
Groton, CT 06349
SUBMITTED BY:
Symmes Maini & McKee Associates
1000 Massachusetts Avenue
Cambridge, MA 02138
A/E Contract Number: N40085-18-D-8703
(Task Order Number: N40085-19-F-6081)
PREPARED BY:
Hazmat: Susan Cahalan, CDW Consultants, Inc.
Civil: Daniel Clasby, Symmes Maini & McKee
Structural: Jason Varney, Simpson Gumpertz & Heger
Architectural: Jennifer Hayes, Symmes Maini & McKee
Interior Design: Alyssa Tompkins, Symmes Maini & McKee
Fire Protection: Peter Mottola, Jensen Hughes
Plumbing: Luis Moreno, Symmes Maini & McKee
Mechanical: Anthony Castelline, Symmes Maini & McKee
Electrical: John Alfeo, Symmes Maini & McKee
Commissioning: Keith Sheldon, Hallam ICS
ISSUE FOR CONSTRUCTION - 1/6/2023
BQ-455 Permanent Party Repairs - Final Submission 1632260
THIS PAGE INTENTIONALLY LEFT BLANK
SECTION 01 20 00 Page 6COVER PAGE
ADDITIONAL COMPULSORY DOCUMENTATION
The following listed documents are part of this Contract Project Manual and made available to the Contractor under separate cover. The Contractor must incorporate the content of each document to the full intent of each document as related to this Project.
Thee following are referenced in their related Specification sections and are considered salient to the CONTRACT BID and AWARD sequence. See Section 00 20 13.00 20 SUPPLEMENTARY INSTRUCTION TO OFFERS, for Project scope of work and related project work schedules.
Supplemental Hazardous Materials Summary Report
The Supplemental Hazardous Materials Summary Report(66 Pgs.). This report summarizes the findings of the supplemental hazardous materials (HAZMAT) survey of the Building BQ-455, Navy Submarine Base, Groton, Connecticut (06/2020). Potential hazardous materials samples collected include asbestos containing materials (ACM) and lead based paint (LBP). This survey presents anticipated elevated levels of HAZMAT material anticipated to be encountered by the Contractor during extension of contracted Work.
Mold Inspection Report
The Mold Inspection Report (149 Pgs.). This report provides a survey of BQ-455 mold determination (06/2020) including a visual inspection, moisture mapping, and air / tape lift sampling for the purpose of determining if elevated levels of mold spore activity and/or visible evidence exist within the specific areas sampled. This survey presents anticipated elevated levels of mold that may be encountered by the Contractor during extension of contracted Work.
Geotechnical Report
Geotechnical Report: New London Naval Submarine Base, Building BQ455 Report (139 Pgs.). Report provides a geotechnical seismic evaluation and recommendations for the proposed renovation of the existing elevators as related to the renovation of Building BQ455, Naval Submarine Base in Groton, Connecticut.(12/2020). This report summarizes the results of a soil boring and test pits program as related to foundation recommendations for the elevator renovation.
BQ-455 Permanent Party Repairs - Final Submission 1632260
A DESIGN PHASE COMMISSIONING PLAN for BQ-455 (23 Pgs.) is part of this Contract Project Manual and made available to the Contractor under separate cover.
Design Phase Commissioning Plan pstock_smma Text Box Page 5 - 70 pstock_smma Text Box Page 73 - 320 pstock_smma Text Box Page 323 - 461 pstock_smma Text Box Page 465 - 487 pstock_smma Pen
PStockman Set to Completed
PStockman Set to Completed
PStockman Set to Completed
PStockman Set to Completed
PStockman Set to Completed
A BUILDING ENCLOSURE COMMISSIONING PLAN (241 Pgs.) is part of this Contract Project Manual and made available to the Contractor under separate cover.
Building Enclosure Commissioning Plan
The Contract Submittal Register; dated 2/08/2021 (241 Pgs.) is provided, generated from the Final Submission Contract documentation.
pstock_smma Text Box Page 483 - 557 pstock_smma Snapshot pstock_smma Text Box Page 559 - 661
PStockman Set to Completed
PStockman Set to Completed
CDW CONSULTANTS, INC.
CIVIL & ENVIRONMENTAL ENGINEERS
6 Huron Drive, Natick, Massachusetts 01760 508-875-2657 www.cdwconsultants.com
SUPPLEMENTAL HAZARDOUS MATERIALS SUMMARY REPORT
Bachelor Enlisted Quarters 455
Navy Submarine Base
Groton, Connecticut
Prepared for
Symmes Maini & Mckee
1000 Massachusetts Avenue
Cambridge, MA 02138
CDW Project # 1860.0
June 26, 2020
Building 455
CDW Project # 1860.0
CDW CONSULTANTS, INC. i
TABLE OF CONTENTS
Page
1.0 INTRODUCTION
2.0 PROJECT UNDERSTANDING
3.0 GENERAL SITE CONDITIONS
4.0 SUMMARY OF PREVIOUS HAZMAT SURVEY
4.1 ACM Findings
4.2 LBP Findings
4.3 PCB Findings
4.4 Wipe Sample Findings
4.5 Mercury in Building Materials
4.6 Visual Hazardous and Universal Waste Survey
5.0 ASBESTOS SURVEY-JUNE 2020
5.1 Methods
5.2 Findings
5.3 Recommendations
6.0 LEAD-BASED PAINT
6.1 Methods
6.2 Findings
6.3 Recommendations
APPENDICES
Appendix A: ACM Quantities Table
Appendix B: Photographs
Appendix C: Asbestos Laboratory Analytical Report
Appendix D: Lead Paint Laboratory Analytical Report
CDW Project #1860.0
1.0 INTRODUCTION
CDW Consultants, Inc. (CDW) is pleased to present this report summarizing the findings of the supplemental hazardous materials (hazmat) survey of the Building 455, Navy Submarine Base, Groton, Connecticut (Site). The hazmat survey was conducted in support of proposed renovations to
Building 455. In June 2020, Ms. Susan Cahalan (Connecticut Asbestos Inspector #001013) conducted an inspection for suspect materials. An inspection is required by the United States
Environmental Protection Agency (USEPA) National Emission Standards for Hazardous Air
Pollutants (NESHAP), prior to scheduled building renovations. The potential hazardous materials samples collected include asbestos containing materials (ACM) and lead based paint (LBP).
Additionally, a comprehensive mold survey was conducted, and the results will be submitted under separate cover. All hazmat work was conducted in accordance with UFC 3-810-01N (Navy and
Marine Corps Environmental Engineering for Facility Construction).
2.0 PROJECT UNDERSTANDING
The hazardous materials survey was conducted via field investigation and research to identify the existence of hazardous materials, which may impact the project’s scope and cost. The project consists of an extensive renovation consisting of; exterior window replacement, exterior foundation vents and door replacement, replacement of the cooling system, replacement of the roof, elevators, and all room finishes. The building does not comply with current Uniform Facilities Criteria (UFC) requirements and will also require compliance with the current fire protection and anti-terrorism force protection criteria. During the initial Hazmat survey, a majority of the berthing rooms were occupied, thus the supplemental hazmat survey was focused on additional berthing rooms.
3.0 GENERAL SITE CONDITIONS
Building 455 is a 78,874 square foot building built in 1978 and last renovated in 1999. The Site building is five-stories that functions as temporary housing for enlisted personnel. Exterior walls are composed of CMU with a brick veneer, and there are concrete exterior walkways with metal railings.
The roof and floor construction are both concrete planks, with the roof covering being a rubber over foam roof. There are 182 dorm rooms, and each consists of a kitchenette, single bathroom and two bedrooms with closets, a few units consist of one bedroom. The building also contains a central lobby, vending area, maintenance office, housekeeping office, TV and games lounges all of which are located on the first floor. In the basement area there is a guest laundry, mechanical room and fire pump room. A crawlspace entrance is also located in the basement but was not entered due to confined space characteristics.
Domestic supply piping is copper and sanitary waste piping is no-hub cast iron piping. Domestic hot water is heated by New London Sub-base, central utility steam. The steam is converted to domestic hot water in a shell-and-tube heat exchanger and stored in insulated tanks. There is a domestic hot water recirculation system with pumps. The building is cooled by a water-cooled, Dunham-Bush chiller located in the first-floor mechanical room. The cooling tower is located on the roof. The chilled water is distributed by base mounted pumps to fan coil units located in all sleeping rooms.
The building is heated by the New London Sub-base, central utility steam. The steam is converted to hot water in a shell-and-tube heat exchanger. The hot water is distributed by base-mounted pumps to fan coil units located in all sleeping rooms. Lighting in each bedroom consists of one or more fluorescent lights mounted on the walls over beds as well as overhead lights in the entry room, storage room, kitchen and bathroom. Lighting in the hallways consists of 1x4 fluorescent fixtures which are suspended from/attached to the ceiling grid and hang below the ceiling.
Aluminum framed windows with silicone/rubber glazing are located throughout the building.
Interior finishes consist of acoustical ceiling tiles, carpet, ceramic tile, painted gypsum board walls
& ceilings and vinyl composition floor tile. Each berthing room consists of carpet and 1’x1’ vinyl floor tiles over concrete, ceramic tile bathroom floor, and smooth plaster/sheetrock walls. The rooms and hallways are identical in construction, which was last renovated in 1999.
No suspect ACM pipe insulation was observed in the lower level, above ceilings or mechanical rooms. Preformed ACM pipe insulation was banned in under a 1975 NESHAP rule and under the
Toxic Substances Control Act (TSCA). CDW did not observe any ACM pipe insulation during the hazmat work, and not likely concealed due to the ban that occurred prior to the building construction.
4.0 SUMMARY OF PREVIOUS HAZMAT SURVEY
In August and September 2019, CDW conducted a preliminary hazmat survey at Building 455. At that time, a majority of the berthing rooms were occupied and there was limited site investigation in those areas. The hazmat survey consisted of the identification and sampling of suspect ACM, LBP, polychlorinated biphenyls (PCBs), wipe samples of metals in dust, mercury in building materials and a visual survey of other universal/hazardous wastes. A summary of finding is provided in the following paragraphs.
4.1 ACM Findings
Suspect ACM that was sampled for laboratory analysis that does not contain asbestos are provided in the below table.
Material Location
Glue Under Rubber Roof
Gray Paper Top of Roof Foam
Gray Paper Bottom Roof Foam
Black Brittle Tar On Roof Vent Pipes
Black Caulk Exterior Roof Penthouse Base at Brick and
Top of Metal Flashing
Gray Caulk Exterior of Penthouse on Roof-Repair Caulk on Brick
Gray Brittle Rubber On Steel Base of Chiller Unit and Associated
Pipe on Roof
Yellow-Black Glue Under Rubber-Roof to Side of Penthouse
Black-Gray Weathered Caulk Around Edge of Roof Drains
Black Pipe Insulation Wrap Chiller Unit Pipes on Roof
White Textured Paint/Plaster On Exterior Ceiling Over Underpass
Gray Grout Under Ceramic Floor Tile Room 116
Gray Grout Under Ceramic Wall Tile, Bathroom Room
White Sink Coating Kitchenette-Room 116
Tan Insulation Inside Metal Dorm Room Door, Rooms 116, 215, 310
Yellow Glue Under Rubber Covebase, Room 116
White Joint Compound Room 116
White Grout Under Bathroom wall Tile, Room 116
White Grout Under Bathroom Floor Tile
Black Mastic Under 1x1 Floor Tile with Black Dots
Gray Covebase Laundry Room
Brown Mastic Laundry Room
Red Penetration Sealant Mechanical Room
Gray Block Insulation Hot Water Tank in Mechanical Room
White Block Insulation Under Aluminum Wrap – Steam Line Entry to
Building, Lobby near Laundry
Yellow Glue On Fiberglass Cover on Hot Water Tank
Black Paper Under Fiberglass on Hot Water Tank
Yellow Glue Under fiberglass Covering pipes at Crawlspace
Entry
White End Cap Sealant Pipe Fitting over Fiberglass Insulation in
Mechanical Room
White End Cap Sealant Pipe Over Fiberglass Fitting on FG-2 Pipe
Round Flex Connector Material Laundry Room HVAC
1’x1’ Floor Tile with Black Dots Basement Lobby
Black/Brown Mastic Under 1’x1’ Floor Tile with Black Dots
Gray Glue Daubs Behind Wood Paneling-TV Room Common
Area First Floor
Tan Glue Under Wood Covebase TV Room Common
Area First Floor
Blue Textured Wall Covering TV Room Common Area First Floor
Yellow Glue Under Laminate Window Sill TV Room
Common Area First Floor
Yellow Carpet Glue Under Laminate Window Sill TV Room
Common Area First Floor
1’x1’ Tan Linoleum Flooring Vending Room
1’x1’ Tan Floor Tile Under Linoleum in Vending
Black Mastic Under 1’x1’ Floor Tile-Vending
Yellow Carpet Mastic Hallways Under Carpet-All Floors
Gray Leveling Compound Under Yellow Carpet Mastic in Hallways
Under Carpet
2’x4’ Ceiling Tiles with Pin Dots Suspended in Halls and Common Areas
2’x4’ Ceiling Tiles with Pin Dots and
Fissures
Suspended in Halls and Common Areas
1’x1’ Tan with Blue Squares Floor Tile Main Lobby, Elevator Lobbies, Kitchens in
Dorm Rooms
Gray Mastic Under 1’x1’ Tan with Blue Squares Floor Tile
Sheetrock Hallways, TV Lounge, Kitchen, Room 116
Joint Compound Hallways, TV Lounge, Kitchen, Room 116
Yellow Mastic Under Rubber Stair Treads
Textured White Coating Underside Concrete Panels Above Ceiling
Tiles-Main Entrance
Yellow/Tan Glue Under Gray-Green Rubber Covebase
Tan Sink Coating Kitchen – Common Main Floor
Laminate Glue Room 116 Countertop Dorm Kitchen
Gray Seam Sealant On HVAC in Kitchen
Tan Glue Under Wood Paneling Main Bathroom 1st
Floor
Black Window Glaze Interior Room 156 and 159
Black Seam Sealant Fiberglass Pipe Insulation to Steel-Closet Near
Elevator
Brown Paper Under Ceramic Floor Main Bathroom 1st Floor
Exterior Gray Caulk Exterior Windows
Gray Caulk Exterior Steel Beams, Located on both Sides of the Steel
Black Flashing Located Behind Brick Façade at SW Stair
Tower Bump Out
Suspect ACM that does contain asbestos are provided in the below table.
Material Description Location
Black Tar Dobs Over Bolts on Flashing, Penthouse to Roof
Gray Caulk Around Louvers, Exterior
Gray Caulk Around Older Doors, Rear, South Side
1'x1' Tan Floor Tile with Black Dots Storage Room Near Mechanical Room, Lower
Level
Black Mastic Damproofing Behind Brick Façade, on CMU and Other
Structural Components (Steel etc.)
Subsurface Transite or Other Subsurface
Pipe Insulation Subsurface
Elevator Brakes Elevators
Remnant ACM Gaskets Steam and Other Metal Pipes
Transite Panels Inside Transformer and Switch Gear Unit
4.2 LBP Findings
Suspect LBP paint chips that were analyzed at a laboratory that does not contain lead are provided in the below table.
Location Lead Concentration (% Weight)
White Paint on Wall – Mechanical Room <0.0080
Yellow Paint on Concrete – Carrier Pad <0.0080
White over Yellow Paint on Metal – HVAC in
Laundry Room
<0.0080
Blue Paint on Wall-Bathroom on First Floor <0.0080
Tan over Red/Blue Paint on Metal Stair Rail <0.0080
Blue Paint on CMU-Kitchen <0.0080
Suspect LBP that does contain lead:
Location Lead Concentration (% Weight)
Gray Paint on Steel Beams-Penthouse on the Roof 0.17
Door Frame Paint-Exterior Door, South Side 0.31
Tan Paint on Metal Door Frame-Electric Room 0.082
White Paint on CMU – Laundry Room 0.24
Brown Paint on Exterior Steel Beams 0.24
Brown Paint on Exterior Steel Beams 0.022
4.3 PCB Findings
Suspect PCB containing building materials sampled for laboratory analysis that does not contain
PCBs are provided in the below able.
Location Concentration (mg/kg)
Gray Paint on Steel-Penthouse ND
Black Caulk-Penthouse ND
Gray Caulk-Penthouse ND
Gray Caulk-Exterior Louvers ND
Exterior Door Caulk-South End ND
White Paint on Metal HVAC in Laundry Room ND
Blue Wall Paint-Main Bathroom First Floor ND
Black Brittle Tar – Steel at Penthouse ND
Exterior Gray Window Caulk ND
Exterior Gray Caulk at Steel Beams
ND
Suspect PCB containing building materials that does contain PCBs are provided in the below able.
White Paint on CMU-Laundry 3.8
Paint on Metal-Stairway 0.59
The PCB analytical results are compared to the United States Environmental Protection Agency
(USEPA) standard of 50 milligrams per kilograms (mg/kg), which is the threshold for bulk product waste, as defined by USEPA 40 CFR § 761.3, and regulated under the TSCA. None of the samples collected had concentrations of PCBs above the TSCA limit of 50 mg/kg. The Connecticut
Department of Energy and Environmental Protection (DEEP) regulates caulking at levels > 1 ppm –
49 mg/kg, however the sample that contains PCBs at 3.8 mg/kg is white paint, and likely represents an older layer of paint on the CMU original to the building date of 1978 and is considered as excluded PCB product, as defined by the USEPA. Furthermore, there are no other sources of PCBs such as other building materials or evidence of spills that could be a source of absorption.
4.4 Wipe Sample Findings
In September 2019, wipe sample collection were collected at various areas of Building 455. The wipe samples were collected utilizing Ghost Wipes. The wipe samples were analyzed for analysis of
RCRA 8 metals using lead in dust by SW846 3050B methodology. A summary of the laboratory analytical results from each sample are compared with health-based risk criteria, including the World
Trade Center (WTC) criteria and USEPA Regional Screening Level (RSL) Industrial Air-Wipe
Equivalent criteria.
In the main mechanical room on the lower level, arsenic exceeded both EPA RSL criteria and WTC criteria in one sample, barium exceeded both EPA RSL criteria and WTC criteria in one sample, lead exceeded EPA RSL in two samples and chromium exceeded EPA RSL Criteria in two samples.
Chromium was detected above EPA RSL Criteria in all other samples (laundry room, 5th floor mechanical room and main entrance floor), except for samples representative of floors near elevators. CDW recommends:
• Clean out all loose material and debris to expose the full floor area.
• HEPA vacuum all surfaces.
• Clean all flat, surfaces with an aggressive cleaner such as ALARATM 1146 or equivalent, capable of removing metal particles from the surfaces, following manufacturer’s instructions for application.
• Test surfaces again using wipe samples; if concentrations exceed the risk-based standards, the decontamination procedures shall be repeated until concentrations meet the standards.
The data tables and laboratory analytical reports are provided in the September 2019 hazmat report.
4.5 Mercury in Building Materials
CDW conducted a visual inspection of rubber flooring suspected to contain mercury. Three samples of the rubber stair treads were collected for laboratory analysis. No mercury was detected in any of the samples.
4.6 Visual Hazardous and Universal Waste Survey
The visual survey for hazardous materials identified mercury-containing light tubes, remnant di (2-ethylhexyl phthalate (DEHP)-containing light ballasts, mercury containing thermostats and switches, lead and tritium batteries, refrigerants, oil containing old door retractors and other hazardous materials. No hazardous materials sampling or analysis was conducted as part of this survey. A list of OHMs identified are included in the below table.
Est.
Quantity Units
Compact Fluorescent Bulbs Throughout 200 EA
Fluorescent Bulbs (Mercury)
Mechanical Rooms, Dorm
Room Kitchens, Hallways, Common Areas, Exterior
Underpass
600 Tubes
DEHP Light Ballasts Mechanical and Utility
Rooms 60 Each
Electronic Ballasts
Mechanical Rooms, Dorm
Room Kitchens, Hallways, Common Areas, Exterior
Underpass
300 Each
Thermostats and Switches Throughout, Mechanical 150 Ampules
Est.
Quantity Units
(Mercury) Rooms
Older Door Retractors with Oil Utility, Mechanical Rooms, Laundry, Stairwells 40 Each
Emergency Light Batteries (Lead) Throughout 40 EA
Refrigerants HVAC and Chiller 1000 Gallons
Transformer Fluid Transformer 200 Gallons
Exit Signs (Tritium) Stairwells, Exits, Other 60 EA
Hydraulic Fluid From Elevator 200 Gallons
5.0 ASBESTOS SURVEY-JUNE 2020
5.1 Methods
On June 4, 5 and 8, 2020, CDW conducted the supplemental asbestos survey. The investigative work for the asbestos survey included conducting a visual inspection of physically accessible areas of the subject areas. Accompanying the mold technician, to evaluate berthing rooms, it was determined all the rooms were uniform and homogenous and were last renovated in 1999. Many of the berthing rooms were still occupied, but at a lower percentage as the preliminary survey. Once the visual inspection was completed, the building components were categorized into homogeneous areas. CDW collected bulk samples of different homogeneous suspect materials for laboratory analysis of asbestos from representative vacant berthing units from each floor. Hand tools were used to collect bulk samples which were promptly placed in sealed plastic bags using a unique numbering system.
Samples were not collected of non-suspect materials, including wood, fiberglass, plastic/vinyl, concrete, neoprene/rubber, silicone, glass, and carpeting. The bulk samples were delivered under chain of custody to Asbestos Identification Laboratory, Inc. (AIL) located in Woburn, Massachusetts. AIL is a Connecticut licensed (#PH-01412) and NVLAP-accredited laboratory (lab code #200919-0) for asbestos analysis. Bulk samples were analyzed for asbestos content by polarized light microscopy (PLM) using EPA Method 600/R-93/116. A positive stop method was used – if one sample in a homogeneous group is positive then additional samples of the same material are not analyzed. Samples analyzed to contain greater than 1% asbestos are to be treated as
ACM as defined by the USEPA, Connecticut DEEP and Connecticut Department of Labor, Occupational Safety and Health Division.
5.2 Findings
The laboratory analytical results of suspect ACM are provided in the below table.
Field ID Material Location Result % Asbestos
1A, 1B, 1C, 1D, 1E, 1F, 1G, 1H, 1I, 1J
1’x1’ Floor Tile, Gray with Black Pin Dots
Berthing Rooms, Foyers and Kitchens, Collected from Rooms 105, 113, 225, 206, 321, 311, 406, 425, 516 and 520
None Detected
2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2I, 2J
Gray Mastic Underneath
1’x1’ Floor Tile
Berthing Rooms, Foyers and Kitchens, Collected from Rooms 105, 113, 225, 206, 321, 311, 406, 425, 516 and 520
None Detected
3A, 3B, 3C, 3D, 3E, 3F, 3G, 3H, 3I, 3J
Yellow-Gray Carpet
Glue
Berthing Rooms, Collected from Rooms
105, 113, 225, 206, 321, 311, 406, 425, 516 and
4A, 4B, 4C, 4D, 4E Tan/Yellow Glue Located Under Blue
Rubber Cove Base in
Berthing Rooms, Collected from Rooms
113, 225, 321, 425, and
None Detected
5A, 5B, 5C, 5D, 5E Tan/Yellow Glue Located Under Tan
Rubber Cove Base in
Berthing Rooms, Collected from Rooms
113, 225, 321, 425, and
None Detected
6A, 6B, 6C, 6D, 6E, 6F, 6G, 6H, 6I, 6J
Gray Levelastic Located Under Carpet and Floor Tile Over
Concrete in Berthing
Rooms, Collected from
Rooms 105, 113, 225, 206, 321, 311, 406, 425, 516 and 520
7A, 7B, 7C White-Tan Sink Coating Berthing Rooms, Kitchen Sink, Collected from Rooms 113, 321 and 520
None Detected
8A, 8B, 8C, 8D, 8E, 8F, 8G, 8H, 8I, 8J
White-Gray Joint
Compound
Berthing Rooms, Seams on Sheetrock and
Window Skim, Collected from Rooms
105, 113, 225, 206, 321, 311, 406, 425, 516 and
None Detected
9A, 9B, 9C, 9D, 9E, 9F, 9G, 9H, 9I, 9J
Sheetrock Berthing Rooms, Collected from Rooms
105, 113, 225, 206, 321, 311, 406, 425, 516 and
10A, 10B, 10C, 10D, 10E
White Grout Berthing Rooms, In-
Between White Ceramic
Wall Tile in Shower, Collected from Rooms
105, 206, 311, 425, and
11A, 11B, 11C, 11D, 11E
Gray-White Mastic Berthing Rooms, Under
White Ceramic Wall
Tile in Shower, Collected from Rooms
105, 206, 311, 425, and
None Detected
12A, 12B, 12C, 12D, 12E
Gray Grout Berthing Rooms, In-
Between Ceramic Floor
Tile in Bathrooms, Collected from Rooms
105, 206, 311, 425, and
None Detected
13A, 13B, 13C, 13D, 13E
Tan-Gray Settling Bed Berthing Rooms, Under
Ceramic Floor Tile in
Bathrooms, Collected from Rooms 105, 206, 311, 425, and 516
None Detected
14A, 14B, 14C, 14D, 14E
Tan-Yellow Glue Daub Under Room Number
Plates on Doors to
Berthing Rooms, Collected from Room
Doors 106, 220, 311, 411 and 505
None Detected
16A, 16B, 16C Tan Glue on Black
Fiberglass
Inside Metal HVAC
Above Suspended
Ceiling Tile in Berthing
Room Foyer in Room
None Detected
17A, 17B, 17C Black Penetration
Sealant
Through Wall Room
None Detected
18A, 18B, 18C White Penetration
Sealant
Room 505 Through
Wall from Hallway to
Bathroom
None Detected
19A, 19B Gray Seam Sealant On Metal HVAC, Room
None Detected
20A, 20B, 20C Tan-Yellow Mastic On Exposed CMU-
Behind Wall in
Bathroom Room 306
None Detected
21A, 21B, 21C Gray Door Caulk Interior Door Buried in
Wall, Room 306, Exposed due to
Construction
2% Chrysotile
22A, 22B, 22C Tan Glue Daub Behind Bathroom
Mirror in Room 306
None Detected
23A, 23B, 23C Dark Brown-Black Glue
Daub
Located Behind Vanity
That was Removed for
Construction in Room
15% Chrysotile
Chrysotile = Asbestos Mineral
CDW Inspected behind the façade brick cuts from a lift provided by others. The ACM containing black coating material located behind the brick façade is visible at higher elevations on the building.
The black coating is typically found behind blue foamboard and some rubber near the underside of windows. The black coating was also noted to be in contact with some structural steel and bolts. The previously sampled non-acm window caulking and expansion joint caulk is homogenous at higher and lower elevations. ACM quantities from the 2019 and 2020 hazmat inspections are included in
Appendix A. Photographs of newly identified ACM are provided in Appendix B. The laboratory analytical report is provided in Appendix C.
5.3 Recommendations
Prior to renovations, all rooms should be explored for doors with ACM caulk that may have been sheet-rocked over. Additionally, areas behind existing bathroom vanities should be inspected for the
ACM-containing black-brown glue daubs. Prior to disturbance, the ACM identified must be abated by a State of Connecticut-licensed asbestos abatement contractor following all federal, military and state regulations governing asbestos abatement. The USEPA is responsible for enforcing the federal asbestos regulations for renovation and demolition under 40 CFR, Part 61, Subpart M, of the
NESHAP. State Regulations for asbestos abatement include the Connecticut Department of Labor, Occupational Safety and Health Division, Connecticut DEEP and Connecticut Department of Health.
A copy of the asbestos air quality sampling must be conducted under USEPA regulations following asbestos abatement and prior to re-occupancy of the spaces. If additional materials are discovered that have not been sampled, those materials should be considered ACM until laboratory analysis determines otherwise.
6.0 LEAD-BASED PAINT
6.1 Methods
CDW performed a visual inspection of painted surfaces and collected additional samples from different color paints on various types of building component substrates. Samples were submitted to
EMSL Laboratories in Cinnaminson, New Jersey for analysis via Atomic Absorption Spectrometry
(AAS).
6.2 Findings
The laboratory analytical results of suspect LBP are provided in the below table. The laboratory analytical report is provided in Appendix D.
Sample ID
Location Lead
Concentration
(% Weight)
LP-1
Yellow Over Brown/Blue on Steel Beam Behind
Exterior Facade 0.30
LP-2 Brown Paint on Exterior Steel Window Lintel 0.084
LP-3A White Wall Paint-Interior Berthing Room <0.0080
LP-3B White Wall Paint-Interior Berthing Room <0.0080
LP-4A Tan Over Blue Paint on Metal Stairs, Interior <0.0080
Sample ID
Location
Concentration
(% Weight)
LP-4B Tan Over Blue Paint on Metal Stairs, Interior <0.0080
LP-5A Black Stair Rail Paint, Interior 0.036
LP-5B Black Stair Rail Paint, Interior 0.036
LP-6A Blue Paint on Metal Door Frames 0.013
LP-6B Blue Paint on Metal Door Frames <0.0080
The results of the testing revealed that five of the ten samples analyzed had detectable concentrations of lead. The USEPA defines LBP as any paint or surface coating that contains lead equal to exceeding one milligram per square centimeter (1.0 mg/cm2) or 0.5% by weight. The OSHA lead-in-construction standard and the Navy defines lead containing paint (LCP) as a paint or coating containing any detectable level of lead. Based on the criteria listed above, five samples contain detectable levels of lead. None of the samples contain lead greater than 0.5% by weight.
6.3 Recommendations
Based on the conclusions of this testing, the following recommendations are offered:
• In accordance with the EPA Lead Renovation, Repair, and Painting (RRP) Rule 40 CFR 745, workers, visitors and the public must be protected from lead dust generated during the demolition of LBP or LCP coated surfaces.
• Components identified to contain the presence of lead should not be disturbed in an uncontrolled manner. Disturbance of these materials should only be done by properly trained personnel in a controlled and documented manner to allow for the safety of the workers, bystanders and disposal of waste materials.
• Lead-based paint wastes must be properly characterized to determine whether they are hazardous wastes to determine proper disposal requirements.
• During demolition or renovation, paint materials containing lead should not be sanded, scraped, drilled, or otherwise altered unless proper engineering controls are used to prevent migration of fugitive lead containing dust from the work area. Under OSHA regulations, any demolition or renovation to be performed at a structure where lead in paint and dust is present must be performed in accordance with a worker protection policy, including, but not limited to, appropriate training, medical monitoring, respiratory protection, and other protective equipment. Additionally, comply with guidelines outlined in specifications UFGS-02 83 13.00
20 and UFGS-02 83 19.13 10.
• Those components/colors not tested, should be tested for lead content prior to disturbance that may cause airborne release of lead.
Limitations
The conclusions are limited to the information available at the time of the field survey and the scope of services, as defined. No subsurface soil or groundwater sampling and analysis was performed. Where access to portions of the Site or to structures on the site was unavailable or limited, CDW renders no opinion as to the presence of hazardous material or the presence of indirect evidence related to hazardous material in that portion of the site or structure. This report cannot be solely relied upon for renovation or demolition. The sampling performed forms the basis for conclusions expressed and areas inaccessible for testing limits those conclusions. No other conclusions, interpretations or recommendations are contained or implied in this report other than those expressed. While CDW followed industry standards during the inspection, we do not warrant that all suspect hazardous building materials were identified in or on the buildings and shall not be held liable related to future abatement costs related to hazardous materials that are either not discovered or not appropriately characterized. This is due in part to inherent problems with every building inspection, such as, but not limited to:
• Seemingly homogeneous materials that are not in fact homogeneous;
• Seemingly representative locations that are not in fact representative;
• Layered materials that are not uniformly present or are isolated;
• Materials that are present and accessible but were not considered to be hazardous,
• Materials that are present in an isolated and limited quantity; and
• Material that is present in locations that are unsafe or otherwise difficult to access.
Client acknowledges that CDW's inspection is limited and all hazardous materials may only become apparent during the course of future renovation or demolition. During the course of future renovation/demolition work, it is likely that additional hazardous materials or materials suspected of being hazardous will be identified. Such materials should be assumed to be hazardous unless appropriate evaluation or sampling and analysis demonstrate otherwise. No other use of this report is warranted without the written consent of CDW Consultants, Inc.
CDW appreciates the opportunity to provide our services to you on this project.
Very truly yours, CDW CONSULTANTS, INC.
Susan Cahalan, PG, ISSP-SA
Senior Environmental Geologist
APPENDIX A
ACM Quantities
TABLE 1
ACM Quantities
Building 455
Navy Submarine Base
Groton, Connecticut
HA No. Material Description NESHAP Cat. Location Est. Quantity Units
1 Black Tar Dobs Cat. 2 Non-friable ACM Over Bolts on Flashing, Penthouse to Roof 120 EACH
2 Gray Caulk Cat. 2 Non-friable ACM Around Louvers, Exterior 164 LF
3 Gray Caulk Cat. 2 Non-friable ACM Around Older Doors, Rear, South Side 144 LF
4 1'x1' Tan Floor Tile with Black Dots Cat. 1 Non-Friable ACM Storage Room Near Mechanical Room, Lower Level 1,200 SF
5 Remnant Floor Tiles and Mastic Presumed ACM Isolated patches, May be Under Carpets in Rooms not
Accessed
2,000 SF
6 Black Glue Daubs Cat. 2 Non-friable ACM Behind Vanities in Bathrooms (Presumed 5 SF per Room) 550 SF
7 Doors with Caulk Cat. 2 Non-friable ACM Under Sheetrock - Left in Place from Renovaton 80 EACH
8 Black Mastic Damproofing Cat. 2 Non-friable ACM Behind Brick Façade, on CMU and Other Structural
Components (Steel etc.)
14,000 SF
9 Remnant Caulk Presumed ACM Around Window Openings, Old Under New 1,200 LF
Subsurface Transite or Other Subsurface Pipe
Insulation Presumed ACM Subsurface 2,000 LF
11 Elevator Brakes Presumed ACM Elevators 2 EACH
12 Remnant ACM Gaskets Presumed ACM Stream Lines, Other Metal Pipes 150 EACH
13 Transite Panels Presumed ACM Inside Transformer and Switch Gear Unit 50 SF
NA = Not Applicable. SF = Square Feet. LF=Linear Feet
HA = Homogenous Area
APPENDIX B
Photographs
Old Door Sheetrocked Over Contains ACM Caulk – Room 306
Yellow Mastic On Concrete Behind Sheetrock Does Not Contain
ACM – Room 306
Black Glue Daubs Do Contain ACM – Room 306
Closeup of Black Glue Daubs – Room 306
APPENDIX C
Asbestos Laboratory Analytical Report
Batch: 53677
165 New Boston St., Ste 227 Woburn, MA 01801
781-932-9600 Web: www.asbestosidentificationlab.com
Email: mikemanning@asbestosidentificationlab.com
Asbestos Identification Laboratory
Dear Susan Cahalan, Thank you Susan Cahalan for your business.
Michael Manning Owner/Director
Asbestos Identification Laboratory has completed the analysis of the samples from your office for the above referenced project.
The information and analysis contained in this report have been generated using the EPA /600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials. Materials or products that contain more than 1% of any kind or combination of asbestos are considered an asbestos containing building material as determined by the EPA. This Polarized Light Microscope (PLM) technique may be performed either by visual estimation or point counting. Point counting provides a determination of the area percentage of asbestos in a sample. If the asbestos is estimated to be less than 10% by visual estimation of friable material, the determination may be repeated using the point counting technique. The results of the point counting supersede visual PLM results. Results in this report only relate to the items tested. This report may not be used by the customer to claim product endorsement by NVLAP or any other U.S. Government Agency.
June 25, 2020
Susan Cahalan CDW Consultants, Inc.
6 Huron Drive Natick, MA 01760
Project Name: Navy Subase Building 455, Groton, CT
Project Number:
Date Sampled: 2020-06-04
Work Received: 2020-06-19
Work Analyzed: 2020-06-23
Analysis Method: BULK PLM ANALYSIS EPA/600/R-93/116
• NVLAP Lab Code: 200919-0
• Massachusetts Certification License: AA000208
• State of Connecticut, Department of Public Health Approved Environmental Laboratory Registration Number: PH-0142
• State of Maine, Department of Environmental Protection Asbestos Analytical Laboratory License Number: LB-0078(Bulk) LA-0087(Air)
• State of Rhode Island and Providence Plantations. Department of Health Certification: AAL-121
• State of Vermont, Department of Health Environmental Health License AL934461
Laboratory results represent the analysis of samples as submitted by the customer. Information regarding sample location, description, area, volume, etc., was provided by the customer. Asbestos Identification Laboratory is not responsible for sample collection activities or analytical method limitations. Unless notified in writing to return samples, Asbestos Identification Laboratory discards customer samples after 30 days. Samples containing subsamples or layers will be analyzed separately when applicable. Reports are kept at Asbestos Identification Laboratory for three years. This report shall not be reproduced, except in full, without the written consent of Asbestos Identification Laboratory.
BQ-455 Permanent Party Repairs - Final Submission 1632260 pstock_smma Text Box
June 25, 2020
Susan Cahalan CDW Consultants, Inc.
6 Huron Drive Natick, MA 01760
Project Name: Navy Subase Building 455, Groton, CT
Project Number:
Date Sampled: 2020-06-04
Work Received: 2020-06-19
Work Analyzed: 2020-06-23
Analysis Method: BULK PLM ANALYSIS EPA/600/R-93/116
Asbestos %Material Color Non-Asbestos %LocationFieldID
LabID gray Non-Fibrous 100
599785
1A Berthing Rooms Foyers/Kitchen
1x1 Floor Tile Gray + Pindots
None Detected gray Non-Fibrous 100
599786
1B Berthing Rooms Foyers/Kitchen
1x1 Floor Tile Gray + Pindots
None Detected gray Non-Fibrous 100
599787
1C Berthing Rooms Foyers/Kitchen
1x1 Floor Tile Gray + Pindots
None Detected gray Non-Fibrous 100
599788
1D Berthing Rooms Foyers/Kitchen
1x1 Floor Tile Gray + Pindots
None Detected gray Non-Fibrous 100
599789
1E Berthing Rooms Foyers/Kitchen
1x1 Floor Tile Gray + Pindots
None Detected gray Non-Fibrous 100
599790
1F Berthing Rooms Foyers/Kitchen
1x1 Floor Tile Gray + Pindots
None Detected gray Non-Fibrous 100
599791
1G Berthing Rooms Foyers/Kitchen
1x1 Floor Tile Gray + Pindots
None Detected gray Non-Fibrous 100
599792
1H Berthing Rooms Foyers/Kitchen
1x1 Floor Tile Gray + Pindots
None Detected gray Non-Fibrous 100
599793
1I Berthing Rooms Foyers/Kitchen
1x1 Floor Tile Gray + Pindots
None Detected gray Non-Fibrous 100
599794
1J Berthing Rooms Foyers/Kitchen
1x1 Floor Tile Gray + Pindots
None Detected gray Non-Fibrous 100
599795
2A Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100
599796
2B Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100
599797
2C Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100
599798
2D Under 1x1 Floor TileGray Mastic None Detected
Page 1 of 8Thursday 25 June
Asbestos %Material Color Non-Asbestos %LocationFieldID
LabID gray Non-Fibrous 100
599799
2E Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100
599800
2F Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100
599801
2G Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100
599802
2H Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100
599803
2I Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100
599804
2J Under 1x1 Floor TileGray Mastic None Detected yellow Non-Fibrous 100
599805
3A Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100
599806
3B Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100
599807
3C Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100
599808
3D Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100
599809
3E Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100
599810
3F Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100
599811
3G Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100
599812
3H Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100
599813
3I Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100
599814
3J Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100
599815
4A Under Blue Rubber Cove Base Berthing Units
Tan/Yellow Glue None Detected yellow Non-Fibrous 100
599816
4B Under Blue Rubber Cove Base Berthing Units
Tan/Yellow Glue None Detected
Page 2 of 8Thursday 25 June yellow Non-Fibrous 100
599817
4C Under Blue Rubber Cove Base Berthing Units
Tan/Yellow Glue None Detected yellow Non-Fibrous 100
599818
4D Under Blue Rubber Cove Base Berthing Units
Tan/Yellow Glue None Detected yellow Non-Fibrous 100
599819
4E Under Blue Rubber Cove Base Berthing Units
Tan/Yellow Glue None Detected tan Non-Fibrous 100
599820
5A Under Tan Rubber Cove Base Berthing Rooms
Tan-Gray Glue None Detected tan Non-Fibrous 100
599821
5B Under Tan Rubber Cove Base Berthing Rooms
Tan-Gray Glue None Detected tan Non-Fibrous 100
599822
5C Under Tan Rubber Cove Base Berthing Rooms
Tan-Gray Glue None Detected tan Non-Fibrous 100
599823
5D Under Tan Rubber Cove Base Berthing Rooms
Tan-Gray Glue None Detected tan Non-Fibrous 100
599824
5E Under Tan Rubber Cove Base Berthing Rooms
Tan-Gray Glue None Detected gray Non-Fibrous 100
599825
6A Under Carpet and Floor Tile Berthing Rooms
Gray Levelastic None Detected gray Non-Fibrous 100
599826
6B Under Carpet and Floor Tile Berthing Rooms
Gray Levelastic None Detected gray Non-Fibrous 100
599827
6C Under Carpet and Floor Tile Berthing Rooms
Gray Levelastic None Detected gray Non-Fibrous 100
599828
6D Under Carpet and Floor Tile Berthing Rooms
Gray Levelastic None Detected gray Non-Fibrous 100
599829
6E Under Carpet and Floor Tile Berthing Rooms
Gray Levelastic None Detected gray Non-Fibrous 100
599830
6F Under Carpet and Floor Tile Berthing Rooms
Gray Levelastic None Detected gray Non-Fibrous 100
599831
6G Under Carpet and Floor Tile Berthing Rooms
Gray Levelastic None Detected gray Non-Fibrous 100
599832
6H Under Carpet and Floor Tile Berthing Rooms
Gray Levelastic None Detected gray Non-Fibrous 100
599833
6I Under Carpet and Floor Tile Berthing Rooms
Gray Levelastic None Detected gray Non-Fibrous 100
599834
6J Under Carpet and Floor Tile Berthing Rooms
Gray Levelastic None Detected
Page 3 of 8Thursday 25 June tan Cellulose 5
Non-Fibrous 95 599835
7A Kitchens in Berthing Rooms
White-Tan Sink Coating None Detected tan Cellulose 5 Non-Fibrous 95
599836
7B Kitchens in Berthing Rooms
White-Tan Sink Coating None Detected tan Cellulose 5 Non-Fibrous 95
599837
7C Kitchens in Berthing Rooms
White-Tan Sink Coating None Detected white Non-Fibrous 100
599838
8A Berthing RoomsWhite Gray Joint Compound
None Detected white Non-Fibrous 100
599839
8B Berthing RoomsWhite Gray Joint Compound
None Detected white Non-Fibrous 100
599840
8C Berthing RoomsWhite Gray Joint Compound
None Detected white Non-Fibrous 100
599841
8D Berthing RoomsWhite Gray Joint Compound
None Detected white Non-Fibrous 100
599842
8E Berthing RoomsWhite Gray Joint Compound
None Detected white Non-Fibrous 100
599843
8F Berthing RoomsWhite Gray Joint Compound
None Detected white Non-Fibrous 100
599844
8G Berthing RoomsWhite Gray Joint Compound
None Detected white Non-Fibrous 100
599845
8H Berthing RoomsWhite Gray Joint Compound
None Detected white Non-Fibrous 100
599846
8I Berthing RoomsWhite Gray Joint Compound
None Detected white Non-Fibrous 100
599847
8J Berthing RoomsWhite Gray Joint Compound
None Detected multi Cellulose 10 Non-Fibrous 90
599848
9A Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90
599849
9B Berthing RoomsSheetrock None Detected gray Cellulose 2 Non-Fibrous 98
599850
9C Berthing RoomsSheetrock None Detected gray Cellulose 2 Non-Fibrous 98
599851
9D Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90
599852
9E Berthing RoomsSheetrock None Detected
Page 4 of 8Thursday 25 June multi Cellulose 10
Non-Fibrous 90 599853
9F Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90
599854
9G Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90
599855
9H Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90
599856
9I Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90
599857
9J Berthing RoomsSheetrock None Detected white Non-Fibrous 100
599858
10A Between Ceramic Tile Bathrooms
White Wall Grout None Detected white Non-Fibrous 100
599859
10B Between Ceramic Tile Bathrooms
White Wall Grout None Detected white Non-Fibrous 100
599860
10C Between Ceramic Tile Bathrooms
White Wall Grout None Detected white Non-Fibrous 100
599861
10D Between Ceramic Tile Bathrooms
White Wall Grout None Detected white Non-Fibrous 100
599862
10E Between Ceramic Tile Bathrooms
White Wall Grout None Detected tan Non-Fibrous 100
599863
11A Under Ceramic Wall Tile Bathrooms
Gray-White Mastic None Detected tan Non-Fibrous 100
599864
11B Under Ceramic Wall Tile Bathrooms
Gray-White Mastic None Detected tan Non-Fibrous 100
599865
11C Under Ceramic Wall Tile Bathrooms
Gray-White Mastic None Detected tan Non-Fibrous 100
599866
11D Under Ceramic Wall Tile Bathrooms
Gray-White Mastic None Detected tan Non-Fibrous 100
599867
11E Under Ceramic Wall Tile Bathrooms
Gray-White Mastic None Detected gray Non-Fibrous 100
599868
12A Ceramic Floor Tiles Bathrooms
Gray Grout None Detected gray Non-Fibrous 100
599869
12B Ceramic Floor Tiles Bathrooms
Gray Grout None Detected gray Non-Fibrous 100
599870
12C Ceramic Floor Tiles Bathrooms
Gray Grout None Detected
Page 5 of 8Thursday 25 June gray Non-Fibrous 100
599871
12D Ceramic Floor Tiles Bathrooms
Gray Grout None Detected gray Non-Fibrous 100
599872
12E Ceramic Floor Tiles Bathrooms
Gray Grout None Detected gray Non-Fibrous 100
599873
13A Under Ceramic Floor Tiles Bathrooms
Tan-Gray Setting Bed None Detected gray Non-Fibrous 100
599874
13B Under Ceramic Floor Tiles Bathrooms
Tan-Gray Setting Bed None Detected gray Non-Fibrous 100
599875
13C Under Ceramic Floor Tiles Bathrooms
Tan-Gray Setting Bed None Detected gray Non-Fibrous 100
599876
13D Under Ceramic Floor Tiles Bathrooms
Tan-Gray Setting Bed None Detected gray Non-Fibrous 100
599877
13E Under Ceramic Floor Tiles Bathrooms
Tan-Gray Setting Bed None Detected yellow Non-Fibrous 100
599878
14A Under Room # Plate Front of Doors
Yellow-Tan Glue Daub None Detected yellow Non-Fibrous 100
599879
14B Under Room # Plate Front of Doors
Yellow-Tan Glue Daub None Detected yellow Non-Fibrous 100
599880
14C Under Room # Plate Front of Doors
Yellow-Tan Glue Daub None Detected yellow Non-Fibrous 100
599881
14D Under Room # Plate Front of Doors
Yellow-Tan Glue Daub None Detected yellow Non-Fibrous 100
599882
14E Under Room # Plate Front of Doors
Yellow-Tan Glue Daub None Detected white Non-Fibrous 100
599883
15A Top of Wall to Concrete Ceiling Berthing Rooms
Hard White Caulk None Detected white Non-Fibrous 100
599884
15B Top of Wall to Concrete Ceiling Berthing Rooms
Hard White Caulk None Detected white Non-Fibrous 100
599885
15C Top of Wall to Concrete Ceiling Berthing Rooms
Hard White Caulk None Detected white Non-Fibrous 100
599886
15D Top of Wall to Concrete Ceiling Berthing Rooms
Hard White Caulk None Detected white Non-Fibrous 100
599887
15E Top of Wall to Concrete Ceiling Berthing Rooms
Hard White Caulk None Detected yellow Non-Fibrous 100
599888
16A Inside HVACTan Glue on Black Fiberglass
None Detected
Page 6 of 8Thursday 25 June yellow Non-Fibrous 100
599889
16B Inside HVACTan Glue on Black Fiberglass
None Detected yellow Non-Fibrous 100
599890
16C Inside HVACTan Glue on Black Fiberglass
None Detected black Non-Fibrous 100
599891
17A Thru Wall Rm 113Black Penetration Sealant None Detected black Non-Fibrous 100
599892
17B Thru Wall Rm 113Black Penetration Sealant None Detected black Non-Fibrous 100
599893
17C Thru Wall Rm 113Black Penetration Sealant None Detected white Non-Fibrous 100
599894
18A Rm 505 Wall to BathWhite Penetration Sealant None Detected white Non-Fibrous 100
599895
18B Rm 505 Wall to BathWhite Penetration Sealant None Detected white Non-Fibrous 100
599896
18C Rm 505 Wall to BathWhite Penetration Sealant None Detected gray Non-Fibrous 100
599897
19A On HVAC Rm 505Gray Seam Sealant None Detected gray Non-Fibrous 100
599898
19B On HVAC Rm 505Gray Seam Sealant None Detected yellow Non-Fibrous 100
599899
20A On Exposed CMU Rm 306 Bathroom
Tan Yellow Mastic None Detected yellow Non-Fibrous 100
599900
20B On Exposed CMU Rm 306 Bathroom
Tan Yellow Mastic None Detected yellow Non-Fibrous 100
599901
20C On Exposed CMU Rm 306 Bathroom
Tan Yellow Mastic None Detected
Detected Chrysotile 2 gray Non-Fibrous 98
599902
21A Interior Door Buried in Wall- 306
Old Gray Door Caulk
599903
21B Interior Door Buried in Wall- 306
Old Gray Door Caulk Not Analyzed
599904
21C Interior Door Buried in Wall- 306
Old Gray Door Caulk Not Analyzed tan Non-Fibrous 100
599905
22A Behind Bathroom Mirror Rm 306
Tan Glue Daub None Detected tan Non-Fibrous 100
599906
22B Behind Bathroom Mirror Rm 306
Tan Glue Daub None Detected
Page 7 of 8Thursday 25 June tan Non-Fibrous 100
599907
22C Behind Bathroom Mirror Rm 306
Tan Glue Daub None Detected
Detected Chrysotile 15 black Non-Fibrous 85
599908
23A Behind Vanity Rm 306Dark Brown Black Glue Daub
599909
23B Behind Vanity Rm 306Dark Brown Black Glue Daub
Not Analyzed
599910
23C Behind Vanity Rm 306Dark Brown Black Glue Daub
Not Analyzed
Analyzed by: 53677Batch:
Page 8 of 8Thursday 25 June End of Report
BQ-455 Permanent Party Repairs - Final Submission 1632260 pstock_smma Text Box
APPENDIX D
Lead in Paint Laboratory Analytical Report
Client Sample Description ConcentrationLab ID Analyzed Weight
Collected
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com
Attn: Susan Cahalan CDW Consultants 6 Huron Drive Natick, MA 01760
Received: 06/23/20 10:30 AM
NavySubase Building 455, Groton, CT
Fax:
Phone: (508) 875-2657
Project:
6/5/2020Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
202005415 CustomerID: CDWC26 CustomerPO:
ProjectID:
EMSL Order:
0.2718 Site: yellow/ brown / blue on steel beam
202005415-0001LP-1 0.30 % wt6/25/2020 g6/5/2020
0.2601 Site: brown paint on window lintd
202005415-0002LP-2 0.084 % wt6/25/2020 g6/5/2020
0.2628 Site: white wall paint interior berthing rooms
202005415-0003LP-3A <0.0080 % wt6/25/2020 g6/5/2020
0.2798 Site: white wall paint interior berthing rooms
202005415-0004LP-3B <0.0080 % wt6/25/2020 g6/5/2020
0.2727 Site: tan / blue paint on metal stairs - interior
202005415-0005LP-4A <0.0080 % wt6/25/2020 g6/5/2020
0.2845 Site: tan / blue paint on metal stairs - interior
202005415-0006LP-4B <0.0080 % wt6/25/2020 g6/5/2020
0.2940 Site: black stair rail paint
202005415-0007LP-5A 0.036 % wt6/25/2020 g6/5/2020
0.2569 Site: black stair rail paint
202005…