This document provides details for a federal solicitation seeking renovations and repairs at Naval Submarine Base New London. The solicitation number is N4008523R2530 and is being issued by the Department of the Navy Naval Facilities Engineering Command. Interested parties are instructed to review the solicitation and all accompanying attachments for requirements regarding the scope of work. Relevant repairs and renovations are to be completed at the specified military base as part of the contract award. The response deadline and anticipated award date are not stated.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIFICATION

ADDITIONAL COMPULSORY DOCUMENTATION

Permanent Party Repairs BQ455 Project Number:1632260

At

NAVAL SUBASE

Groton, CT 06349

SUBMITTED BY:

Symmes Maini & McKee Associates

1000 Massachusetts Avenue

Cambridge, MA 02138

A/E Contract Number: N40085-18-D-8703

(Task Order Number: N40085-19-F-6081)

PREPARED BY:

Hazmat: Susan Cahalan, CDW Consultants, Inc.

Civil: Daniel Clasby, Symmes Maini & McKee

Structural: Jason Varney, Simpson Gumpertz & Heger

Architectural: Jennifer Hayes, Symmes Maini & McKee

Interior Design: Alyssa Tompkins, Symmes Maini & McKee

Fire Protection: Peter Mottola, Jensen Hughes

Plumbing: Luis Moreno, Symmes Maini & McKee

Mechanical: Anthony Castelline, Symmes Maini & McKee

Electrical: John Alfeo, Symmes Maini & McKee

Commissioning: Keith Sheldon, Hallam ICS

ISSUE FOR CONSTRUCTION - 1/6/2023

BQ-455 Permanent Party Repairs - Final Submission 1632260

THIS PAGE INTENTIONALLY LEFT BLANK

SECTION 01 20 00 Page 6COVER PAGE

ADDITIONAL COMPULSORY DOCUMENTATION

The following listed documents are part of this Contract Project Manual and made available to the Contractor under separate cover. The Contractor must incorporate the content of each document to the full intent of each document as related to this Project.

Thee following are referenced in their related Specification sections and are considered salient to the CONTRACT BID and AWARD sequence. See Section 00 20 13.00 20 SUPPLEMENTARY INSTRUCTION TO OFFERS, for Project scope of work and related project work schedules.

Supplemental Hazardous Materials Summary Report

The Supplemental Hazardous Materials Summary Report(66 Pgs.). This report summarizes the findings of the supplemental hazardous materials (HAZMAT) survey of the Building BQ-455, Navy Submarine Base, Groton, Connecticut (06/2020). Potential hazardous materials samples collected include asbestos containing materials (ACM) and lead based paint (LBP). This survey presents anticipated elevated levels of HAZMAT material anticipated to be encountered by the Contractor during extension of contracted Work.

Mold Inspection Report

The Mold Inspection Report (149 Pgs.). This report provides a survey of BQ-455 mold determination (06/2020) including a visual inspection, moisture mapping, and air / tape lift sampling for the purpose of determining if elevated levels of mold spore activity and/or visible evidence exist within the specific areas sampled. This survey presents anticipated elevated levels of mold that may be encountered by the Contractor during extension of contracted Work.

Geotechnical Report

Geotechnical Report: New London Naval Submarine Base, Building BQ455 Report (139 Pgs.). Report provides a geotechnical seismic evaluation and recommendations for the proposed renovation of the existing elevators as related to the renovation of Building BQ455, Naval Submarine Base in Groton, Connecticut.(12/2020). This report summarizes the results of a soil boring and test pits program as related to foundation recommendations for the elevator renovation.

BQ-455 Permanent Party Repairs - Final Submission 1632260

A DESIGN PHASE COMMISSIONING PLAN for BQ-455 (23 Pgs.) is part of this Contract Project Manual and made available to the Contractor under separate cover.

Design Phase Commissioning Plan pstock_smma Text Box Page 5 - 70 pstock_smma Text Box Page 73 - 320 pstock_smma Text Box Page 323 - 461 pstock_smma Text Box Page 465 - 487 pstock_smma Pen

PStockman Set to Completed

PStockman Set to Completed

PStockman Set to Completed

PStockman Set to Completed

PStockman Set to Completed

A BUILDING ENCLOSURE COMMISSIONING PLAN (241 Pgs.) is part of this Contract Project Manual and made available to the Contractor under separate cover.

Building Enclosure Commissioning Plan

The Contract Submittal Register; dated 2/08/2021 (241 Pgs.) is provided, generated from the Final Submission Contract documentation.

pstock_smma Text Box Page 483 - 557 pstock_smma Snapshot pstock_smma Text Box Page 559 - 661

PStockman Set to Completed

PStockman Set to Completed

CDW CONSULTANTS, INC.

CIVIL & ENVIRONMENTAL ENGINEERS

6 Huron Drive, Natick, Massachusetts 01760 508-875-2657 www.cdwconsultants.com

SUPPLEMENTAL HAZARDOUS MATERIALS SUMMARY REPORT

Bachelor Enlisted Quarters 455

Navy Submarine Base

Groton, Connecticut

Prepared for

Symmes Maini & Mckee

1000 Massachusetts Avenue

Cambridge, MA 02138

CDW Project # 1860.0

June 26, 2020

Building 455

CDW Project # 1860.0

CDW CONSULTANTS, INC. i

TABLE OF CONTENTS

Page

1.0 INTRODUCTION

2.0 PROJECT UNDERSTANDING

3.0 GENERAL SITE CONDITIONS

4.0 SUMMARY OF PREVIOUS HAZMAT SURVEY

4.1 ACM Findings

4.2 LBP Findings

4.3 PCB Findings

4.4 Wipe Sample Findings

4.5 Mercury in Building Materials

4.6 Visual Hazardous and Universal Waste Survey

5.0 ASBESTOS SURVEY-JUNE 2020

5.1 Methods

5.2 Findings

5.3 Recommendations

6.0 LEAD-BASED PAINT

6.1 Methods

6.2 Findings

6.3 Recommendations

APPENDICES

Appendix A: ACM Quantities Table

Appendix B: Photographs

Appendix C: Asbestos Laboratory Analytical Report

Appendix D: Lead Paint Laboratory Analytical Report

CDW Project #1860.0

1.0 INTRODUCTION

CDW Consultants, Inc. (CDW) is pleased to present this report summarizing the findings of the supplemental hazardous materials (hazmat) survey of the Building 455, Navy Submarine Base, Groton, Connecticut (Site). The hazmat survey was conducted in support of proposed renovations to

Building 455. In June 2020, Ms. Susan Cahalan (Connecticut Asbestos Inspector #001013) conducted an inspection for suspect materials. An inspection is required by the United States

Environmental Protection Agency (USEPA) National Emission Standards for Hazardous Air

Pollutants (NESHAP), prior to scheduled building renovations. The potential hazardous materials samples collected include asbestos containing materials (ACM) and lead based paint (LBP).

Additionally, a comprehensive mold survey was conducted, and the results will be submitted under separate cover. All hazmat work was conducted in accordance with UFC 3-810-01N (Navy and

Marine Corps Environmental Engineering for Facility Construction).

2.0 PROJECT UNDERSTANDING

The hazardous materials survey was conducted via field investigation and research to identify the existence of hazardous materials, which may impact the project’s scope and cost. The project consists of an extensive renovation consisting of; exterior window replacement, exterior foundation vents and door replacement, replacement of the cooling system, replacement of the roof, elevators, and all room finishes. The building does not comply with current Uniform Facilities Criteria (UFC) requirements and will also require compliance with the current fire protection and anti-terrorism force protection criteria. During the initial Hazmat survey, a majority of the berthing rooms were occupied, thus the supplemental hazmat survey was focused on additional berthing rooms.

3.0 GENERAL SITE CONDITIONS

Building 455 is a 78,874 square foot building built in 1978 and last renovated in 1999. The Site building is five-stories that functions as temporary housing for enlisted personnel. Exterior walls are composed of CMU with a brick veneer, and there are concrete exterior walkways with metal railings.

The roof and floor construction are both concrete planks, with the roof covering being a rubber over foam roof. There are 182 dorm rooms, and each consists of a kitchenette, single bathroom and two bedrooms with closets, a few units consist of one bedroom. The building also contains a central lobby, vending area, maintenance office, housekeeping office, TV and games lounges all of which are located on the first floor. In the basement area there is a guest laundry, mechanical room and fire pump room. A crawlspace entrance is also located in the basement but was not entered due to confined space characteristics.

Domestic supply piping is copper and sanitary waste piping is no-hub cast iron piping. Domestic hot water is heated by New London Sub-base, central utility steam. The steam is converted to domestic hot water in a shell-and-tube heat exchanger and stored in insulated tanks. There is a domestic hot water recirculation system with pumps. The building is cooled by a water-cooled, Dunham-Bush chiller located in the first-floor mechanical room. The cooling tower is located on the roof. The chilled water is distributed by base mounted pumps to fan coil units located in all sleeping rooms.

The building is heated by the New London Sub-base, central utility steam. The steam is converted to hot water in a shell-and-tube heat exchanger. The hot water is distributed by base-mounted pumps to fan coil units located in all sleeping rooms. Lighting in each bedroom consists of one or more fluorescent lights mounted on the walls over beds as well as overhead lights in the entry room, storage room, kitchen and bathroom. Lighting in the hallways consists of 1x4 fluorescent fixtures which are suspended from/attached to the ceiling grid and hang below the ceiling.

Aluminum framed windows with silicone/rubber glazing are located throughout the building.

Interior finishes consist of acoustical ceiling tiles, carpet, ceramic tile, painted gypsum board walls

& ceilings and vinyl composition floor tile. Each berthing room consists of carpet and 1’x1’ vinyl floor tiles over concrete, ceramic tile bathroom floor, and smooth plaster/sheetrock walls. The rooms and hallways are identical in construction, which was last renovated in 1999.

No suspect ACM pipe insulation was observed in the lower level, above ceilings or mechanical rooms. Preformed ACM pipe insulation was banned in under a 1975 NESHAP rule and under the

Toxic Substances Control Act (TSCA). CDW did not observe any ACM pipe insulation during the hazmat work, and not likely concealed due to the ban that occurred prior to the building construction.

4.0 SUMMARY OF PREVIOUS HAZMAT SURVEY

In August and September 2019, CDW conducted a preliminary hazmat survey at Building 455. At that time, a majority of the berthing rooms were occupied and there was limited site investigation in those areas. The hazmat survey consisted of the identification and sampling of suspect ACM, LBP, polychlorinated biphenyls (PCBs), wipe samples of metals in dust, mercury in building materials and a visual survey of other universal/hazardous wastes. A summary of finding is provided in the following paragraphs.

4.1 ACM Findings

Suspect ACM that was sampled for laboratory analysis that does not contain asbestos are provided in the below table.

Material Location

Glue Under Rubber Roof

Gray Paper Top of Roof Foam

Gray Paper Bottom Roof Foam

Black Brittle Tar On Roof Vent Pipes

Black Caulk Exterior Roof Penthouse Base at Brick and

Top of Metal Flashing

Gray Caulk Exterior of Penthouse on Roof-Repair Caulk on Brick

Gray Brittle Rubber On Steel Base of Chiller Unit and Associated

Pipe on Roof

Yellow-Black Glue Under Rubber-Roof to Side of Penthouse

Black-Gray Weathered Caulk Around Edge of Roof Drains

Black Pipe Insulation Wrap Chiller Unit Pipes on Roof

White Textured Paint/Plaster On Exterior Ceiling Over Underpass

Gray Grout Under Ceramic Floor Tile Room 116

Gray Grout Under Ceramic Wall Tile, Bathroom Room

White Sink Coating Kitchenette-Room 116

Tan Insulation Inside Metal Dorm Room Door, Rooms 116, 215, 310

Yellow Glue Under Rubber Covebase, Room 116

White Joint Compound Room 116

White Grout Under Bathroom wall Tile, Room 116

White Grout Under Bathroom Floor Tile

Black Mastic Under 1x1 Floor Tile with Black Dots

Gray Covebase Laundry Room

Brown Mastic Laundry Room

Red Penetration Sealant Mechanical Room

Gray Block Insulation Hot Water Tank in Mechanical Room

White Block Insulation Under Aluminum Wrap – Steam Line Entry to

Building, Lobby near Laundry

Yellow Glue On Fiberglass Cover on Hot Water Tank

Black Paper Under Fiberglass on Hot Water Tank

Yellow Glue Under fiberglass Covering pipes at Crawlspace

Entry

White End Cap Sealant Pipe Fitting over Fiberglass Insulation in

Mechanical Room

White End Cap Sealant Pipe Over Fiberglass Fitting on FG-2 Pipe

Round Flex Connector Material Laundry Room HVAC

1’x1’ Floor Tile with Black Dots Basement Lobby

Black/Brown Mastic Under 1’x1’ Floor Tile with Black Dots

Gray Glue Daubs Behind Wood Paneling-TV Room Common

Area First Floor

Tan Glue Under Wood Covebase TV Room Common

Area First Floor

Blue Textured Wall Covering TV Room Common Area First Floor

Yellow Glue Under Laminate Window Sill TV Room

Common Area First Floor

Yellow Carpet Glue Under Laminate Window Sill TV Room

Common Area First Floor

1’x1’ Tan Linoleum Flooring Vending Room

1’x1’ Tan Floor Tile Under Linoleum in Vending

Black Mastic Under 1’x1’ Floor Tile-Vending

Yellow Carpet Mastic Hallways Under Carpet-All Floors

Gray Leveling Compound Under Yellow Carpet Mastic in Hallways

Under Carpet

2’x4’ Ceiling Tiles with Pin Dots Suspended in Halls and Common Areas

2’x4’ Ceiling Tiles with Pin Dots and

Fissures

Suspended in Halls and Common Areas

1’x1’ Tan with Blue Squares Floor Tile Main Lobby, Elevator Lobbies, Kitchens in

Dorm Rooms

Gray Mastic Under 1’x1’ Tan with Blue Squares Floor Tile

Sheetrock Hallways, TV Lounge, Kitchen, Room 116

Joint Compound Hallways, TV Lounge, Kitchen, Room 116

Yellow Mastic Under Rubber Stair Treads

Textured White Coating Underside Concrete Panels Above Ceiling

Tiles-Main Entrance

Yellow/Tan Glue Under Gray-Green Rubber Covebase

Tan Sink Coating Kitchen – Common Main Floor

Laminate Glue Room 116 Countertop Dorm Kitchen

Gray Seam Sealant On HVAC in Kitchen

Tan Glue Under Wood Paneling Main Bathroom 1st

Floor

Black Window Glaze Interior Room 156 and 159

Black Seam Sealant Fiberglass Pipe Insulation to Steel-Closet Near

Elevator

Brown Paper Under Ceramic Floor Main Bathroom 1st Floor

Exterior Gray Caulk Exterior Windows

Gray Caulk Exterior Steel Beams, Located on both Sides of the Steel

Black Flashing Located Behind Brick Façade at SW Stair

Tower Bump Out

Suspect ACM that does contain asbestos are provided in the below table.

Material Description Location

Black Tar Dobs Over Bolts on Flashing, Penthouse to Roof

Gray Caulk Around Louvers, Exterior

Gray Caulk Around Older Doors, Rear, South Side

1'x1' Tan Floor Tile with Black Dots Storage Room Near Mechanical Room, Lower

Level

Black Mastic Damproofing Behind Brick Façade, on CMU and Other

Structural Components (Steel etc.)

Subsurface Transite or Other Subsurface

Pipe Insulation Subsurface

Elevator Brakes Elevators

Remnant ACM Gaskets Steam and Other Metal Pipes

Transite Panels Inside Transformer and Switch Gear Unit

4.2 LBP Findings

Suspect LBP paint chips that were analyzed at a laboratory that does not contain lead are provided in the below table.

Location Lead Concentration (% Weight)

White Paint on Wall – Mechanical Room <0.0080

Yellow Paint on Concrete – Carrier Pad <0.0080

White over Yellow Paint on Metal – HVAC in

Laundry Room

<0.0080

Blue Paint on Wall-Bathroom on First Floor <0.0080

Tan over Red/Blue Paint on Metal Stair Rail <0.0080

Blue Paint on CMU-Kitchen <0.0080

Suspect LBP that does contain lead:

Location Lead Concentration (% Weight)

Gray Paint on Steel Beams-Penthouse on the Roof 0.17

Door Frame Paint-Exterior Door, South Side 0.31

Tan Paint on Metal Door Frame-Electric Room 0.082

White Paint on CMU – Laundry Room 0.24

Brown Paint on Exterior Steel Beams 0.24

Brown Paint on Exterior Steel Beams 0.022

4.3 PCB Findings

Suspect PCB containing building materials sampled for laboratory analysis that does not contain

PCBs are provided in the below able.

Location Concentration (mg/kg)

Gray Paint on Steel-Penthouse ND

Black Caulk-Penthouse ND

Gray Caulk-Penthouse ND

Gray Caulk-Exterior Louvers ND

Exterior Door Caulk-South End ND

White Paint on Metal HVAC in Laundry Room ND

Blue Wall Paint-Main Bathroom First Floor ND

Black Brittle Tar – Steel at Penthouse ND

Exterior Gray Window Caulk ND

Exterior Gray Caulk at Steel Beams

ND

Suspect PCB containing building materials that does contain PCBs are provided in the below able.

White Paint on CMU-Laundry 3.8

Paint on Metal-Stairway 0.59

The PCB analytical results are compared to the United States Environmental Protection Agency

(USEPA) standard of 50 milligrams per kilograms (mg/kg), which is the threshold for bulk product waste, as defined by USEPA 40 CFR § 761.3, and regulated under the TSCA. None of the samples collected had concentrations of PCBs above the TSCA limit of 50 mg/kg. The Connecticut

Department of Energy and Environmental Protection (DEEP) regulates caulking at levels > 1 ppm –

49 mg/kg, however the sample that contains PCBs at 3.8 mg/kg is white paint, and likely represents an older layer of paint on the CMU original to the building date of 1978 and is considered as excluded PCB product, as defined by the USEPA. Furthermore, there are no other sources of PCBs such as other building materials or evidence of spills that could be a source of absorption.

4.4 Wipe Sample Findings

In September 2019, wipe sample collection were collected at various areas of Building 455. The wipe samples were collected utilizing Ghost Wipes. The wipe samples were analyzed for analysis of

RCRA 8 metals using lead in dust by SW846 3050B methodology. A summary of the laboratory analytical results from each sample are compared with health-based risk criteria, including the World

Trade Center (WTC) criteria and USEPA Regional Screening Level (RSL) Industrial Air-Wipe

Equivalent criteria.

In the main mechanical room on the lower level, arsenic exceeded both EPA RSL criteria and WTC criteria in one sample, barium exceeded both EPA RSL criteria and WTC criteria in one sample, lead exceeded EPA RSL in two samples and chromium exceeded EPA RSL Criteria in two samples.

Chromium was detected above EPA RSL Criteria in all other samples (laundry room, 5th floor mechanical room and main entrance floor), except for samples representative of floors near elevators. CDW recommends:

• Clean out all loose material and debris to expose the full floor area.

• HEPA vacuum all surfaces.

• Clean all flat, surfaces with an aggressive cleaner such as ALARATM 1146 or equivalent, capable of removing metal particles from the surfaces, following manufacturer’s instructions for application.

• Test surfaces again using wipe samples; if concentrations exceed the risk-based standards, the decontamination procedures shall be repeated until concentrations meet the standards.

The data tables and laboratory analytical reports are provided in the September 2019 hazmat report.

4.5 Mercury in Building Materials

CDW conducted a visual inspection of rubber flooring suspected to contain mercury. Three samples of the rubber stair treads were collected for laboratory analysis. No mercury was detected in any of the samples.

4.6 Visual Hazardous and Universal Waste Survey

The visual survey for hazardous materials identified mercury-containing light tubes, remnant di (2-ethylhexyl phthalate (DEHP)-containing light ballasts, mercury containing thermostats and switches, lead and tritium batteries, refrigerants, oil containing old door retractors and other hazardous materials. No hazardous materials sampling or analysis was conducted as part of this survey. A list of OHMs identified are included in the below table.

Est.

Quantity Units

Compact Fluorescent Bulbs Throughout 200 EA

Fluorescent Bulbs (Mercury)

Mechanical Rooms, Dorm

Room Kitchens, Hallways, Common Areas, Exterior

Underpass

600 Tubes

DEHP Light Ballasts Mechanical and Utility

Rooms 60 Each

Electronic Ballasts

Mechanical Rooms, Dorm

Room Kitchens, Hallways, Common Areas, Exterior

Underpass

300 Each

Thermostats and Switches Throughout, Mechanical 150 Ampules

Est.

Quantity Units

(Mercury) Rooms

Older Door Retractors with Oil Utility, Mechanical Rooms, Laundry, Stairwells 40 Each

Emergency Light Batteries (Lead) Throughout 40 EA

Refrigerants HVAC and Chiller 1000 Gallons

Transformer Fluid Transformer 200 Gallons

Exit Signs (Tritium) Stairwells, Exits, Other 60 EA

Hydraulic Fluid From Elevator 200 Gallons

5.0 ASBESTOS SURVEY-JUNE 2020

5.1 Methods

On June 4, 5 and 8, 2020, CDW conducted the supplemental asbestos survey. The investigative work for the asbestos survey included conducting a visual inspection of physically accessible areas of the subject areas. Accompanying the mold technician, to evaluate berthing rooms, it was determined all the rooms were uniform and homogenous and were last renovated in 1999. Many of the berthing rooms were still occupied, but at a lower percentage as the preliminary survey. Once the visual inspection was completed, the building components were categorized into homogeneous areas. CDW collected bulk samples of different homogeneous suspect materials for laboratory analysis of asbestos from representative vacant berthing units from each floor. Hand tools were used to collect bulk samples which were promptly placed in sealed plastic bags using a unique numbering system.

Samples were not collected of non-suspect materials, including wood, fiberglass, plastic/vinyl, concrete, neoprene/rubber, silicone, glass, and carpeting. The bulk samples were delivered under chain of custody to Asbestos Identification Laboratory, Inc. (AIL) located in Woburn, Massachusetts. AIL is a Connecticut licensed (#PH-01412) and NVLAP-accredited laboratory (lab code #200919-0) for asbestos analysis. Bulk samples were analyzed for asbestos content by polarized light microscopy (PLM) using EPA Method 600/R-93/116. A positive stop method was used – if one sample in a homogeneous group is positive then additional samples of the same material are not analyzed. Samples analyzed to contain greater than 1% asbestos are to be treated as

ACM as defined by the USEPA, Connecticut DEEP and Connecticut Department of Labor, Occupational Safety and Health Division.

5.2 Findings

The laboratory analytical results of suspect ACM are provided in the below table.

Field ID Material Location Result % Asbestos

1A, 1B, 1C, 1D, 1E, 1F, 1G, 1H, 1I, 1J

1’x1’ Floor Tile, Gray with Black Pin Dots

Berthing Rooms, Foyers and Kitchens, Collected from Rooms 105, 113, 225, 206, 321, 311, 406, 425, 516 and 520

None Detected

2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2I, 2J

Gray Mastic Underneath

1’x1’ Floor Tile

Berthing Rooms, Foyers and Kitchens, Collected from Rooms 105, 113, 225, 206, 321, 311, 406, 425, 516 and 520

None Detected

3A, 3B, 3C, 3D, 3E, 3F, 3G, 3H, 3I, 3J

Yellow-Gray Carpet

Glue

Berthing Rooms, Collected from Rooms

105, 113, 225, 206, 321, 311, 406, 425, 516 and

4A, 4B, 4C, 4D, 4E Tan/Yellow Glue Located Under Blue

Rubber Cove Base in

Berthing Rooms, Collected from Rooms

113, 225, 321, 425, and

None Detected

5A, 5B, 5C, 5D, 5E Tan/Yellow Glue Located Under Tan

Rubber Cove Base in

Berthing Rooms, Collected from Rooms

113, 225, 321, 425, and

None Detected

6A, 6B, 6C, 6D, 6E, 6F, 6G, 6H, 6I, 6J

Gray Levelastic Located Under Carpet and Floor Tile Over

Concrete in Berthing

Rooms, Collected from

Rooms 105, 113, 225, 206, 321, 311, 406, 425, 516 and 520

7A, 7B, 7C White-Tan Sink Coating Berthing Rooms, Kitchen Sink, Collected from Rooms 113, 321 and 520

None Detected

8A, 8B, 8C, 8D, 8E, 8F, 8G, 8H, 8I, 8J

White-Gray Joint

Compound

Berthing Rooms, Seams on Sheetrock and

Window Skim, Collected from Rooms

105, 113, 225, 206, 321, 311, 406, 425, 516 and

None Detected

9A, 9B, 9C, 9D, 9E, 9F, 9G, 9H, 9I, 9J

Sheetrock Berthing Rooms, Collected from Rooms

105, 113, 225, 206, 321, 311, 406, 425, 516 and

10A, 10B, 10C, 10D, 10E

White Grout Berthing Rooms, In-

Between White Ceramic

Wall Tile in Shower, Collected from Rooms

105, 206, 311, 425, and

11A, 11B, 11C, 11D, 11E

Gray-White Mastic Berthing Rooms, Under

White Ceramic Wall

Tile in Shower, Collected from Rooms

105, 206, 311, 425, and

None Detected

12A, 12B, 12C, 12D, 12E

Gray Grout Berthing Rooms, In-

Between Ceramic Floor

Tile in Bathrooms, Collected from Rooms

105, 206, 311, 425, and

None Detected

13A, 13B, 13C, 13D, 13E

Tan-Gray Settling Bed Berthing Rooms, Under

Ceramic Floor Tile in

Bathrooms, Collected from Rooms 105, 206, 311, 425, and 516

None Detected

14A, 14B, 14C, 14D, 14E

Tan-Yellow Glue Daub Under Room Number

Plates on Doors to

Berthing Rooms, Collected from Room

Doors 106, 220, 311, 411 and 505

None Detected

16A, 16B, 16C Tan Glue on Black

Fiberglass

Inside Metal HVAC

Above Suspended

Ceiling Tile in Berthing

Room Foyer in Room

None Detected

17A, 17B, 17C Black Penetration

Sealant

Through Wall Room

None Detected

18A, 18B, 18C White Penetration

Sealant

Room 505 Through

Wall from Hallway to

Bathroom

None Detected

19A, 19B Gray Seam Sealant On Metal HVAC, Room

None Detected

20A, 20B, 20C Tan-Yellow Mastic On Exposed CMU-

Behind Wall in

Bathroom Room 306

None Detected

21A, 21B, 21C Gray Door Caulk Interior Door Buried in

Wall, Room 306, Exposed due to

Construction

2% Chrysotile

22A, 22B, 22C Tan Glue Daub Behind Bathroom

Mirror in Room 306

None Detected

23A, 23B, 23C Dark Brown-Black Glue

Daub

Located Behind Vanity

That was Removed for

Construction in Room

15% Chrysotile

Chrysotile = Asbestos Mineral

CDW Inspected behind the façade brick cuts from a lift provided by others. The ACM containing black coating material located behind the brick façade is visible at higher elevations on the building.

The black coating is typically found behind blue foamboard and some rubber near the underside of windows. The black coating was also noted to be in contact with some structural steel and bolts. The previously sampled non-acm window caulking and expansion joint caulk is homogenous at higher and lower elevations. ACM quantities from the 2019 and 2020 hazmat inspections are included in

Appendix A. Photographs of newly identified ACM are provided in Appendix B. The laboratory analytical report is provided in Appendix C.

5.3 Recommendations

Prior to renovations, all rooms should be explored for doors with ACM caulk that may have been sheet-rocked over. Additionally, areas behind existing bathroom vanities should be inspected for the

ACM-containing black-brown glue daubs. Prior to disturbance, the ACM identified must be abated by a State of Connecticut-licensed asbestos abatement contractor following all federal, military and state regulations governing asbestos abatement. The USEPA is responsible for enforcing the federal asbestos regulations for renovation and demolition under 40 CFR, Part 61, Subpart M, of the

NESHAP. State Regulations for asbestos abatement include the Connecticut Department of Labor, Occupational Safety and Health Division, Connecticut DEEP and Connecticut Department of Health.

A copy of the asbestos air quality sampling must be conducted under USEPA regulations following asbestos abatement and prior to re-occupancy of the spaces. If additional materials are discovered that have not been sampled, those materials should be considered ACM until laboratory analysis determines otherwise.

6.0 LEAD-BASED PAINT

6.1 Methods

CDW performed a visual inspection of painted surfaces and collected additional samples from different color paints on various types of building component substrates. Samples were submitted to

EMSL Laboratories in Cinnaminson, New Jersey for analysis via Atomic Absorption Spectrometry

(AAS).

6.2 Findings

The laboratory analytical results of suspect LBP are provided in the below table. The laboratory analytical report is provided in Appendix D.

Sample ID

Location Lead

Concentration

(% Weight)

LP-1

Yellow Over Brown/Blue on Steel Beam Behind

Exterior Facade 0.30

LP-2 Brown Paint on Exterior Steel Window Lintel 0.084

LP-3A White Wall Paint-Interior Berthing Room <0.0080

LP-3B White Wall Paint-Interior Berthing Room <0.0080

LP-4A Tan Over Blue Paint on Metal Stairs, Interior <0.0080

Sample ID

Location

Concentration

(% Weight)

LP-4B Tan Over Blue Paint on Metal Stairs, Interior <0.0080

LP-5A Black Stair Rail Paint, Interior 0.036

LP-5B Black Stair Rail Paint, Interior 0.036

LP-6A Blue Paint on Metal Door Frames 0.013

LP-6B Blue Paint on Metal Door Frames <0.0080

The results of the testing revealed that five of the ten samples analyzed had detectable concentrations of lead. The USEPA defines LBP as any paint or surface coating that contains lead equal to exceeding one milligram per square centimeter (1.0 mg/cm2) or 0.5% by weight. The OSHA lead-in-construction standard and the Navy defines lead containing paint (LCP) as a paint or coating containing any detectable level of lead. Based on the criteria listed above, five samples contain detectable levels of lead. None of the samples contain lead greater than 0.5% by weight.

6.3 Recommendations

Based on the conclusions of this testing, the following recommendations are offered:

• In accordance with the EPA Lead Renovation, Repair, and Painting (RRP) Rule 40 CFR 745, workers, visitors and the public must be protected from lead dust generated during the demolition of LBP or LCP coated surfaces.

• Components identified to contain the presence of lead should not be disturbed in an uncontrolled manner. Disturbance of these materials should only be done by properly trained personnel in a controlled and documented manner to allow for the safety of the workers, bystanders and disposal of waste materials.

• Lead-based paint wastes must be properly characterized to determine whether they are hazardous wastes to determine proper disposal requirements.

• During demolition or renovation, paint materials containing lead should not be sanded, scraped, drilled, or otherwise altered unless proper engineering controls are used to prevent migration of fugitive lead containing dust from the work area. Under OSHA regulations, any demolition or renovation to be performed at a structure where lead in paint and dust is present must be performed in accordance with a worker protection policy, including, but not limited to, appropriate training, medical monitoring, respiratory protection, and other protective equipment. Additionally, comply with guidelines outlined in specifications UFGS-02 83 13.00

20 and UFGS-02 83 19.13 10.

• Those components/colors not tested, should be tested for lead content prior to disturbance that may cause airborne release of lead.

Limitations

The conclusions are limited to the information available at the time of the field survey and the scope of services, as defined. No subsurface soil or groundwater sampling and analysis was performed. Where access to portions of the Site or to structures on the site was unavailable or limited, CDW renders no opinion as to the presence of hazardous material or the presence of indirect evidence related to hazardous material in that portion of the site or structure. This report cannot be solely relied upon for renovation or demolition. The sampling performed forms the basis for conclusions expressed and areas inaccessible for testing limits those conclusions. No other conclusions, interpretations or recommendations are contained or implied in this report other than those expressed. While CDW followed industry standards during the inspection, we do not warrant that all suspect hazardous building materials were identified in or on the buildings and shall not be held liable related to future abatement costs related to hazardous materials that are either not discovered or not appropriately characterized. This is due in part to inherent problems with every building inspection, such as, but not limited to:

• Seemingly homogeneous materials that are not in fact homogeneous;

• Seemingly representative locations that are not in fact representative;

• Layered materials that are not uniformly present or are isolated;

• Materials that are present and accessible but were not considered to be hazardous,

• Materials that are present in an isolated and limited quantity; and

• Material that is present in locations that are unsafe or otherwise difficult to access.

Client acknowledges that CDW's inspection is limited and all hazardous materials may only become apparent during the course of future renovation or demolition. During the course of future renovation/demolition work, it is likely that additional hazardous materials or materials suspected of being hazardous will be identified. Such materials should be assumed to be hazardous unless appropriate evaluation or sampling and analysis demonstrate otherwise. No other use of this report is warranted without the written consent of CDW Consultants, Inc.

CDW appreciates the opportunity to provide our services to you on this project.

Very truly yours, CDW CONSULTANTS, INC.

Susan Cahalan, PG, ISSP-SA

Senior Environmental Geologist

APPENDIX A

ACM Quantities

TABLE 1

ACM Quantities

Building 455

Navy Submarine Base

Groton, Connecticut

HA No. Material Description NESHAP Cat. Location Est. Quantity Units

1 Black Tar Dobs Cat. 2 Non-friable ACM Over Bolts on Flashing, Penthouse to Roof 120 EACH

2 Gray Caulk Cat. 2 Non-friable ACM Around Louvers, Exterior 164 LF

3 Gray Caulk Cat. 2 Non-friable ACM Around Older Doors, Rear, South Side 144 LF

4 1'x1' Tan Floor Tile with Black Dots Cat. 1 Non-Friable ACM Storage Room Near Mechanical Room, Lower Level 1,200 SF

5 Remnant Floor Tiles and Mastic Presumed ACM Isolated patches, May be Under Carpets in Rooms not

Accessed

2,000 SF

6 Black Glue Daubs Cat. 2 Non-friable ACM Behind Vanities in Bathrooms (Presumed 5 SF per Room) 550 SF

7 Doors with Caulk Cat. 2 Non-friable ACM Under Sheetrock - Left in Place from Renovaton 80 EACH

8 Black Mastic Damproofing Cat. 2 Non-friable ACM Behind Brick Façade, on CMU and Other Structural

Components (Steel etc.)

14,000 SF

9 Remnant Caulk Presumed ACM Around Window Openings, Old Under New 1,200 LF

Subsurface Transite or Other Subsurface Pipe

Insulation Presumed ACM Subsurface 2,000 LF

11 Elevator Brakes Presumed ACM Elevators 2 EACH

12 Remnant ACM Gaskets Presumed ACM Stream Lines, Other Metal Pipes 150 EACH

13 Transite Panels Presumed ACM Inside Transformer and Switch Gear Unit 50 SF

NA = Not Applicable. SF = Square Feet. LF=Linear Feet

HA = Homogenous Area

APPENDIX B

Photographs

Old Door Sheetrocked Over Contains ACM Caulk – Room 306

Yellow Mastic On Concrete Behind Sheetrock Does Not Contain

ACM – Room 306

Black Glue Daubs Do Contain ACM – Room 306

Closeup of Black Glue Daubs – Room 306

APPENDIX C

Asbestos Laboratory Analytical Report

Batch: 53677

165 New Boston St., Ste 227 Woburn, MA 01801

781-932-9600 Web: www.asbestosidentificationlab.com

Email: mikemanning@asbestosidentificationlab.com

Asbestos Identification Laboratory

Dear Susan Cahalan, Thank you Susan Cahalan for your business.

Michael Manning Owner/Director

Asbestos Identification Laboratory has completed the analysis of the samples from your office for the above referenced project.

The information and analysis contained in this report have been generated using the EPA /600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials. Materials or products that contain more than 1% of any kind or combination of asbestos are considered an asbestos containing building material as determined by the EPA. This Polarized Light Microscope (PLM) technique may be performed either by visual estimation or point counting. Point counting provides a determination of the area percentage of asbestos in a sample. If the asbestos is estimated to be less than 10% by visual estimation of friable material, the determination may be repeated using the point counting technique. The results of the point counting supersede visual PLM results. Results in this report only relate to the items tested. This report may not be used by the customer to claim product endorsement by NVLAP or any other U.S. Government Agency.

June 25, 2020

Susan Cahalan CDW Consultants, Inc.

6 Huron Drive Natick, MA 01760

Project Name: Navy Subase Building 455, Groton, CT

Project Number:

Date Sampled: 2020-06-04

Work Received: 2020-06-19

Work Analyzed: 2020-06-23

Analysis Method: BULK PLM ANALYSIS EPA/600/R-93/116

• NVLAP Lab Code: 200919-0

• Massachusetts Certification License: AA000208

• State of Connecticut, Department of Public Health Approved Environmental Laboratory Registration Number: PH-0142

• State of Maine, Department of Environmental Protection Asbestos Analytical Laboratory License Number: LB-0078(Bulk) LA-0087(Air)

• State of Rhode Island and Providence Plantations. Department of Health Certification: AAL-121

• State of Vermont, Department of Health Environmental Health License AL934461

Laboratory results represent the analysis of samples as submitted by the customer. Information regarding sample location, description, area, volume, etc., was provided by the customer. Asbestos Identification Laboratory is not responsible for sample collection activities or analytical method limitations. Unless notified in writing to return samples, Asbestos Identification Laboratory discards customer samples after 30 days. Samples containing subsamples or layers will be analyzed separately when applicable. Reports are kept at Asbestos Identification Laboratory for three years. This report shall not be reproduced, except in full, without the written consent of Asbestos Identification Laboratory.

BQ-455 Permanent Party Repairs - Final Submission 1632260 pstock_smma Text Box

June 25, 2020

Susan Cahalan CDW Consultants, Inc.

6 Huron Drive Natick, MA 01760

Project Name: Navy Subase Building 455, Groton, CT

Project Number:

Date Sampled: 2020-06-04

Work Received: 2020-06-19

Work Analyzed: 2020-06-23

Analysis Method: BULK PLM ANALYSIS EPA/600/R-93/116

Asbestos %Material Color Non-Asbestos %LocationFieldID

LabID gray Non-Fibrous 100

599785

1A Berthing Rooms Foyers/Kitchen

1x1 Floor Tile Gray + Pindots

None Detected gray Non-Fibrous 100

599786

1B Berthing Rooms Foyers/Kitchen

1x1 Floor Tile Gray + Pindots

None Detected gray Non-Fibrous 100

599787

1C Berthing Rooms Foyers/Kitchen

1x1 Floor Tile Gray + Pindots

None Detected gray Non-Fibrous 100

599788

1D Berthing Rooms Foyers/Kitchen

1x1 Floor Tile Gray + Pindots

None Detected gray Non-Fibrous 100

599789

1E Berthing Rooms Foyers/Kitchen

1x1 Floor Tile Gray + Pindots

None Detected gray Non-Fibrous 100

599790

1F Berthing Rooms Foyers/Kitchen

1x1 Floor Tile Gray + Pindots

None Detected gray Non-Fibrous 100

599791

1G Berthing Rooms Foyers/Kitchen

1x1 Floor Tile Gray + Pindots

None Detected gray Non-Fibrous 100

599792

1H Berthing Rooms Foyers/Kitchen

1x1 Floor Tile Gray + Pindots

None Detected gray Non-Fibrous 100

599793

1I Berthing Rooms Foyers/Kitchen

1x1 Floor Tile Gray + Pindots

None Detected gray Non-Fibrous 100

599794

1J Berthing Rooms Foyers/Kitchen

1x1 Floor Tile Gray + Pindots

None Detected gray Non-Fibrous 100

599795

2A Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100

599796

2B Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100

599797

2C Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100

599798

2D Under 1x1 Floor TileGray Mastic None Detected

Page 1 of 8Thursday 25 June

Asbestos %Material Color Non-Asbestos %LocationFieldID

LabID gray Non-Fibrous 100

599799

2E Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100

599800

2F Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100

599801

2G Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100

599802

2H Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100

599803

2I Under 1x1 Floor TileGray Mastic None Detected gray Non-Fibrous 100

599804

2J Under 1x1 Floor TileGray Mastic None Detected yellow Non-Fibrous 100

599805

3A Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100

599806

3B Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100

599807

3C Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100

599808

3D Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100

599809

3E Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100

599810

3F Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100

599811

3G Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100

599812

3H Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100

599813

3I Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100

599814

3J Berthing UnitsYellow Gray Carpet Glue None Detected yellow Non-Fibrous 100

599815

4A Under Blue Rubber Cove Base Berthing Units

Tan/Yellow Glue None Detected yellow Non-Fibrous 100

599816

4B Under Blue Rubber Cove Base Berthing Units

Tan/Yellow Glue None Detected

Page 2 of 8Thursday 25 June yellow Non-Fibrous 100

599817

4C Under Blue Rubber Cove Base Berthing Units

Tan/Yellow Glue None Detected yellow Non-Fibrous 100

599818

4D Under Blue Rubber Cove Base Berthing Units

Tan/Yellow Glue None Detected yellow Non-Fibrous 100

599819

4E Under Blue Rubber Cove Base Berthing Units

Tan/Yellow Glue None Detected tan Non-Fibrous 100

599820

5A Under Tan Rubber Cove Base Berthing Rooms

Tan-Gray Glue None Detected tan Non-Fibrous 100

599821

5B Under Tan Rubber Cove Base Berthing Rooms

Tan-Gray Glue None Detected tan Non-Fibrous 100

599822

5C Under Tan Rubber Cove Base Berthing Rooms

Tan-Gray Glue None Detected tan Non-Fibrous 100

599823

5D Under Tan Rubber Cove Base Berthing Rooms

Tan-Gray Glue None Detected tan Non-Fibrous 100

599824

5E Under Tan Rubber Cove Base Berthing Rooms

Tan-Gray Glue None Detected gray Non-Fibrous 100

599825

6A Under Carpet and Floor Tile Berthing Rooms

Gray Levelastic None Detected gray Non-Fibrous 100

599826

6B Under Carpet and Floor Tile Berthing Rooms

Gray Levelastic None Detected gray Non-Fibrous 100

599827

6C Under Carpet and Floor Tile Berthing Rooms

Gray Levelastic None Detected gray Non-Fibrous 100

599828

6D Under Carpet and Floor Tile Berthing Rooms

Gray Levelastic None Detected gray Non-Fibrous 100

599829

6E Under Carpet and Floor Tile Berthing Rooms

Gray Levelastic None Detected gray Non-Fibrous 100

599830

6F Under Carpet and Floor Tile Berthing Rooms

Gray Levelastic None Detected gray Non-Fibrous 100

599831

6G Under Carpet and Floor Tile Berthing Rooms

Gray Levelastic None Detected gray Non-Fibrous 100

599832

6H Under Carpet and Floor Tile Berthing Rooms

Gray Levelastic None Detected gray Non-Fibrous 100

599833

6I Under Carpet and Floor Tile Berthing Rooms

Gray Levelastic None Detected gray Non-Fibrous 100

599834

6J Under Carpet and Floor Tile Berthing Rooms

Gray Levelastic None Detected

Page 3 of 8Thursday 25 June tan Cellulose 5

Non-Fibrous 95 599835

7A Kitchens in Berthing Rooms

White-Tan Sink Coating None Detected tan Cellulose 5 Non-Fibrous 95

599836

7B Kitchens in Berthing Rooms

White-Tan Sink Coating None Detected tan Cellulose 5 Non-Fibrous 95

599837

7C Kitchens in Berthing Rooms

White-Tan Sink Coating None Detected white Non-Fibrous 100

599838

8A Berthing RoomsWhite Gray Joint Compound

None Detected white Non-Fibrous 100

599839

8B Berthing RoomsWhite Gray Joint Compound

None Detected white Non-Fibrous 100

599840

8C Berthing RoomsWhite Gray Joint Compound

None Detected white Non-Fibrous 100

599841

8D Berthing RoomsWhite Gray Joint Compound

None Detected white Non-Fibrous 100

599842

8E Berthing RoomsWhite Gray Joint Compound

None Detected white Non-Fibrous 100

599843

8F Berthing RoomsWhite Gray Joint Compound

None Detected white Non-Fibrous 100

599844

8G Berthing RoomsWhite Gray Joint Compound

None Detected white Non-Fibrous 100

599845

8H Berthing RoomsWhite Gray Joint Compound

None Detected white Non-Fibrous 100

599846

8I Berthing RoomsWhite Gray Joint Compound

None Detected white Non-Fibrous 100

599847

8J Berthing RoomsWhite Gray Joint Compound

None Detected multi Cellulose 10 Non-Fibrous 90

599848

9A Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90

599849

9B Berthing RoomsSheetrock None Detected gray Cellulose 2 Non-Fibrous 98

599850

9C Berthing RoomsSheetrock None Detected gray Cellulose 2 Non-Fibrous 98

599851

9D Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90

599852

9E Berthing RoomsSheetrock None Detected

Page 4 of 8Thursday 25 June multi Cellulose 10

Non-Fibrous 90 599853

9F Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90

599854

9G Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90

599855

9H Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90

599856

9I Berthing RoomsSheetrock None Detected multi Cellulose 10 Non-Fibrous 90

599857

9J Berthing RoomsSheetrock None Detected white Non-Fibrous 100

599858

10A Between Ceramic Tile Bathrooms

White Wall Grout None Detected white Non-Fibrous 100

599859

10B Between Ceramic Tile Bathrooms

White Wall Grout None Detected white Non-Fibrous 100

599860

10C Between Ceramic Tile Bathrooms

White Wall Grout None Detected white Non-Fibrous 100

599861

10D Between Ceramic Tile Bathrooms

White Wall Grout None Detected white Non-Fibrous 100

599862

10E Between Ceramic Tile Bathrooms

White Wall Grout None Detected tan Non-Fibrous 100

599863

11A Under Ceramic Wall Tile Bathrooms

Gray-White Mastic None Detected tan Non-Fibrous 100

599864

11B Under Ceramic Wall Tile Bathrooms

Gray-White Mastic None Detected tan Non-Fibrous 100

599865

11C Under Ceramic Wall Tile Bathrooms

Gray-White Mastic None Detected tan Non-Fibrous 100

599866

11D Under Ceramic Wall Tile Bathrooms

Gray-White Mastic None Detected tan Non-Fibrous 100

599867

11E Under Ceramic Wall Tile Bathrooms

Gray-White Mastic None Detected gray Non-Fibrous 100

599868

12A Ceramic Floor Tiles Bathrooms

Gray Grout None Detected gray Non-Fibrous 100

599869

12B Ceramic Floor Tiles Bathrooms

Gray Grout None Detected gray Non-Fibrous 100

599870

12C Ceramic Floor Tiles Bathrooms

Gray Grout None Detected

Page 5 of 8Thursday 25 June gray Non-Fibrous 100

599871

12D Ceramic Floor Tiles Bathrooms

Gray Grout None Detected gray Non-Fibrous 100

599872

12E Ceramic Floor Tiles Bathrooms

Gray Grout None Detected gray Non-Fibrous 100

599873

13A Under Ceramic Floor Tiles Bathrooms

Tan-Gray Setting Bed None Detected gray Non-Fibrous 100

599874

13B Under Ceramic Floor Tiles Bathrooms

Tan-Gray Setting Bed None Detected gray Non-Fibrous 100

599875

13C Under Ceramic Floor Tiles Bathrooms

Tan-Gray Setting Bed None Detected gray Non-Fibrous 100

599876

13D Under Ceramic Floor Tiles Bathrooms

Tan-Gray Setting Bed None Detected gray Non-Fibrous 100

599877

13E Under Ceramic Floor Tiles Bathrooms

Tan-Gray Setting Bed None Detected yellow Non-Fibrous 100

599878

14A Under Room # Plate Front of Doors

Yellow-Tan Glue Daub None Detected yellow Non-Fibrous 100

599879

14B Under Room # Plate Front of Doors

Yellow-Tan Glue Daub None Detected yellow Non-Fibrous 100

599880

14C Under Room # Plate Front of Doors

Yellow-Tan Glue Daub None Detected yellow Non-Fibrous 100

599881

14D Under Room # Plate Front of Doors

Yellow-Tan Glue Daub None Detected yellow Non-Fibrous 100

599882

14E Under Room # Plate Front of Doors

Yellow-Tan Glue Daub None Detected white Non-Fibrous 100

599883

15A Top of Wall to Concrete Ceiling Berthing Rooms

Hard White Caulk None Detected white Non-Fibrous 100

599884

15B Top of Wall to Concrete Ceiling Berthing Rooms

Hard White Caulk None Detected white Non-Fibrous 100

599885

15C Top of Wall to Concrete Ceiling Berthing Rooms

Hard White Caulk None Detected white Non-Fibrous 100

599886

15D Top of Wall to Concrete Ceiling Berthing Rooms

Hard White Caulk None Detected white Non-Fibrous 100

599887

15E Top of Wall to Concrete Ceiling Berthing Rooms

Hard White Caulk None Detected yellow Non-Fibrous 100

599888

16A Inside HVACTan Glue on Black Fiberglass

None Detected

Page 6 of 8Thursday 25 June yellow Non-Fibrous 100

599889

16B Inside HVACTan Glue on Black Fiberglass

None Detected yellow Non-Fibrous 100

599890

16C Inside HVACTan Glue on Black Fiberglass

None Detected black Non-Fibrous 100

599891

17A Thru Wall Rm 113Black Penetration Sealant None Detected black Non-Fibrous 100

599892

17B Thru Wall Rm 113Black Penetration Sealant None Detected black Non-Fibrous 100

599893

17C Thru Wall Rm 113Black Penetration Sealant None Detected white Non-Fibrous 100

599894

18A Rm 505 Wall to BathWhite Penetration Sealant None Detected white Non-Fibrous 100

599895

18B Rm 505 Wall to BathWhite Penetration Sealant None Detected white Non-Fibrous 100

599896

18C Rm 505 Wall to BathWhite Penetration Sealant None Detected gray Non-Fibrous 100

599897

19A On HVAC Rm 505Gray Seam Sealant None Detected gray Non-Fibrous 100

599898

19B On HVAC Rm 505Gray Seam Sealant None Detected yellow Non-Fibrous 100

599899

20A On Exposed CMU Rm 306 Bathroom

Tan Yellow Mastic None Detected yellow Non-Fibrous 100

599900

20B On Exposed CMU Rm 306 Bathroom

Tan Yellow Mastic None Detected yellow Non-Fibrous 100

599901

20C On Exposed CMU Rm 306 Bathroom

Tan Yellow Mastic None Detected

Detected Chrysotile 2 gray Non-Fibrous 98

599902

21A Interior Door Buried in Wall- 306

Old Gray Door Caulk

599903

21B Interior Door Buried in Wall- 306

Old Gray Door Caulk Not Analyzed

599904

21C Interior Door Buried in Wall- 306

Old Gray Door Caulk Not Analyzed tan Non-Fibrous 100

599905

22A Behind Bathroom Mirror Rm 306

Tan Glue Daub None Detected tan Non-Fibrous 100

599906

22B Behind Bathroom Mirror Rm 306

Tan Glue Daub None Detected

Page 7 of 8Thursday 25 June tan Non-Fibrous 100

599907

22C Behind Bathroom Mirror Rm 306

Tan Glue Daub None Detected

Detected Chrysotile 15 black Non-Fibrous 85

599908

23A Behind Vanity Rm 306Dark Brown Black Glue Daub

599909

23B Behind Vanity Rm 306Dark Brown Black Glue Daub

Not Analyzed

599910

23C Behind Vanity Rm 306Dark Brown Black Glue Daub

Not Analyzed

Analyzed by: 53677Batch:

Page 8 of 8Thursday 25 June End of Report

BQ-455 Permanent Party Repairs - Final Submission 1632260 pstock_smma Text Box

APPENDIX D

Lead in Paint Laboratory Analytical Report

Client Sample Description ConcentrationLab ID Analyzed Weight

Collected

EMSL Analytical, Inc.

200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com

Attn: Susan Cahalan CDW Consultants 6 Huron Drive Natick, MA 01760

Received: 06/23/20 10:30 AM

NavySubase Building 455, Groton, CT

Fax:

Phone: (508) 875-2657

Project:

6/5/2020Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

202005415 CustomerID: CDWC26 CustomerPO:

ProjectID:

EMSL Order:

0.2718 Site: yellow/ brown / blue on steel beam

202005415-0001LP-1 0.30 % wt6/25/2020 g6/5/2020

0.2601 Site: brown paint on window lintd

202005415-0002LP-2 0.084 % wt6/25/2020 g6/5/2020

0.2628 Site: white wall paint interior berthing rooms

202005415-0003LP-3A <0.0080 % wt6/25/2020 g6/5/2020

0.2798 Site: white wall paint interior berthing rooms

202005415-0004LP-3B <0.0080 % wt6/25/2020 g6/5/2020

0.2727 Site: tan / blue paint on metal stairs - interior

202005415-0005LP-4A <0.0080 % wt6/25/2020 g6/5/2020

0.2845 Site: tan / blue paint on metal stairs - interior

202005415-0006LP-4B <0.0080 % wt6/25/2020 g6/5/2020

0.2940 Site: black stair rail paint

202005415-0007LP-5A 0.036 % wt6/25/2020 g6/5/2020

0.2569 Site: black stair rail paint

202005…