The Walker Group Architecture, Inc PO Box 541, New Bern, NC 28563
252.636.8778 (PHONE)
252.636.8992 (FAX)
WALKER
GROUP
i n c o r p o r a t e d the
ARCHITECTURE
DISCLOSURE OF INFORMATION
CONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO
THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR
(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE
(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE
FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE
PROPOSED DATE FOR RELEASE.
(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
01/24/2020
System 600
POWERS POWERS
System 600
HEATING PLANT
CONTROLLER
POWERS
System 600
COOLING PLANT
CONTROLLER
POWERS
System 600
FIELD PANEL
AHU-1
MECHANICAL ROOM
FIRST FLOOR
FIELD PLUG-IN
PORTABLE
OPERATOR'S
WORKSTATION
CWP-2
AC-1
· ENABLE/DISABLE
· SPEED
BOILER
RP-2
BACNET MSTP BUS (TYP)
· ON/OFF
· STATUS
BOILER
RP-1
POWERS
System 600
PUMP
CONTROLLER
VAV
ASC
CHILLED WATER SYSTEM :
GENERAL: THE FACILITY SHALL BE SUPPLIED WITH CHILLED WATER FROM AIR-COOLED CHILLER, AC-1. THE DESIGN CHILLED WATER SUPPLY TEMPERATURE IS 45°F.
COOLING: A CALL FOR COOLING IS DETERMINED BY ANY COOLING COIL VALVE BEING 30 PERCENT OPEN FOR A PERIOD OF MORE THAN 3 MINUTES. UPON A CALL FOR COOLING, THE CHILLER AND INTEGRAL PUMPING
PACKAGE SHALL BE ENERGIZED AND RUN FOR A MINIMUM OF 30 MINUTES. THE CHILLER MANUFACTURER'S CONTROL PANEL SHALL MAINTAIN CHILLED WATER SETPOINT (45°F). AN ANTI-CYCLE TIMER SHALL PREVENT THE CHILLER FROM BEING STARTED FOR A PERIOD OF 15 MINUTES AFTER IT SHUTS DOWN DUE TO LOW BUILDING COOLING DEMAND. THE CHILLER MANUFACTURER'S MINIMUM ON AND OFF TIMES MUST BE OBSERVED. THE
ABOVE SEQUENCE SHALL BE ACCOMPLISHED THROUGH THE BUILDING DDC SYSTEM AND CHILLER MANUFACTURER'S CONTROL PANEL. ALL ALARMS AND POINT INFORMATION RESIDING IN THE CHILLER CONTROL PANEL, SHALL BE AVAILABLE THROUGH THE BUILDING DDC SYSTEM.
CHILLER SHALL UTILIZE AN INTEGRAL PUMPING PACKAGE. PUMPS SHALL BE EQUIPPED WITH VARIABLE FREQUENCY DRIVES BUT SHALL OPERATE AT CONSTANT SPEED. PUMPS SHALL OPERATE IN A LEAD/STANDBY
CONFIGURATION, AND THE LEAD PUMP DESIGNATION SHALL ALTERNATE ON A WEEKLY BASIS. IN THE EVENT THE PRIMARY PUMP FAILS TO START DURING OPERATION, IF THE LEAD PUMP PROOF SWITCH DOES NOT DETECT
FLOW WITHIN 30 SECONDS FROM START SIGNAL, THE DDC CONTROLLER SHALL DE-ENERGIZE THE FAILED PUMP, START THE STANDBY PUMP, AND TRANSMIT A PUMP FAILURE ALARM. A PROGRAMMED ANTI-RECYCLE TIMER
SHALL PREVENT PUMP SHORT CYCLING. THE DDC CONTROLLER SHALL AUTOMATICALLY ATTEMPT A RESTART OF THE CIRCULATING PUMPS ON A PERIODIC BASIS TO ACCOMMODATE SERVICE SHUTDOWNS AND EXTENDED
POWER OUTAGES.
SEQUENCE OF OPERATION
ALARMS: ALARM IF CWS TEMPERATURE RISES ABOVE 48°F.
DDC/EMCS SIGNAL/FUNCTION:
CWS TEMPERATURE - STATUS, ALARM
CWR TEMPERATURE - STATUS
CWR TEMPERATURE
INTEGRAL CHILLED WATER PUMP CWP-1 - STATUS, ALARM
INTEGRAL CHILLED WATER PUMP CWP-2 - STATUS, ALARM
CHILLED WATER FLOWMETER - COOLING LOAD (TONS), STATUS
CWS
CWR
CWS
CWR
TO AHU-1
CWP-1
CWP-2
DPS
DI1
DPS
DI2
FMAI3
TS AI2
TS
AI1
CHILLED WATER SYSTEM
LOCAL DDC CONTROLLER
A N
A L
O G
INPUTS
CWS TEMPERATURE
D I G
I T
A L
PUMP CWP-1 STATUS (ON/OFF)
CWR TEMPERATURE
A N
A L
O G
OUTPUTS
AI1
AI2
AI3
DI1
AO1
PUMP CWP-2 STATUS (ON/OFF)DI2
AO2
CHILLED WATER FLOWMETER
MODULATING BYPASS VALVE CONTROL (V-1)
AIR-COOLED CHILLER AC-1
FS DI3
AC-1 FLOW SWITCH
DI3
REPRESENTS COMPONENTS
WHICH ARE INTEGRAL TO
CHILLER PACKAGE
DI4
DDC
DO1
AO2
AI4
CONTROL
PANEL
AC-1 STATUS (ON/OFF)DI4
D I G
I T
A L
AC-1 ENABLE/DISABLEDO1
CWS SETPOINT
AC-1 PERCENTAGE OF LOADAI4
C W
R
2"
PRESSURE GAUGE
(0-100 PSIG TYP.)
COMPOUND
PRIOR TO TAB WORK (TYP.)
REMOVE START-UP STRAINER
FLEX CONNECTION
(TYP. BOTH SIDES)
CWP-1
CWP-2
1/4"
1/4"
2"
2"
2"
CW
S
(4 5°
F)
CWR (59.2°F)
2"
2-1/2"
1"
TANGENTIAL AIR
SEPARATOR
HIGH CAPACITY
AIR VENT
DIAPHRAGM EXPANSION TANK,
PRECHARGE TO 15 PSIG
3/4"
ET
3/4" DRAIN WITH
THREADED HOSE BIBB
PRESSURE GAUGE
(O-100 PSIG)
VENTURI BALANCE
VALVE, 38.2 GPM
PROVIDE 8 WATT/SF SELF
REGULATING HEAT TAPE ON
EXTERIOR PIPING
WELLS FOR PRESSURE /
TEMPERATURE TAP
CONNECTIONS (TYP FOR 4)
AC-1
INTEGRAL TO AIR-COOLED
CHILLER AC-1
C W
S
STRAINER W/
BLOWDOWN VALVE
UNION
CHECK VALVE
TEST WELL
FLOW SWITCH
1" DRAIN LINE AND BALL VALVE
AT LOW POINT IN PIPING (TYP.)
VALVE-SET AT 15 PSIG
PRESSURE REGULATION
SET AT 50 PSIG
RELIEF VALVE
3/4" BYPASS
GLOBE VALVE TO FD
1" MAKE-UP WATER, REFER TO
PLUMBING DRAWINGS FOR
BACKFLOW PREVENTER AND
CONTINUATION
1" TO CHILLER
THERMOMETER
1" COLD WATER
MAKE-UP
C W
R
C W
S
SHOT FEEDER IN
MECHANICAL ROOM
CHILLED WATER SYSTEM FLOW DIAGRAM
SCALE: NO SCALE M-702
A
CHILLED WATER SYSTEM CONTROL DIAGRAM (DDC)
SCALE: NO SCALE M-702
B
BUILDING GLOBAL POINT (DDC)
NO SCALE
SUNSHIELD
OUTSIDE AIR
AI2 H
TAI1
OA TEMPERATURE
OA HUMIDITY
BUILDING DDC CONTROLLER
A N
A L
O G
AI2
AI1
INPUTS
LOCATE ON
NORTH WALL.
2" TEMPORARY
CHILLER
CONNECTION
SUPERVISORY BUILDING
CONTROLLER
SHWP-2
SHWP-1
NOTE: MULTIPLE UNITS
SEQUENCE OF OPERATION
EXHAUST FAN WITH THERMOSTAT (NON-DDC)
EXHAUST FAN SHALL BE CONTROLLED BY A WALL MOUNTED THERMOSTAT AND
INTERLOCKED WITH MOTORIZED DAMPER. UPON A RISE IN SPACE TEMPERATURE
ABOVE 85°F, MOTORIZED DAMPER SHALL OPEN AND FAN SHALL BE ENERGIZED.
UPON FALL IN SPACE TEMPERATURE BELOW 85°F, THE OPPOSITE SHALL OCCUR.
NO SCALE
LINE
VOLTAGE
THERMOSTAT
FAN
MOTOR
T
LINE
VOLTAGE
M MOTORIZED DAMPER
VFD
VFD
VAV
ASC
CWP-1
· ON/OFF
· STATUS
DO2
DO3
CWP-1 ENABLE/DISABLEDO2
CWP-2 ENABLE/DISABLEDO3
DSS CONDENSING UNIT
DSS EVAPORATOR
COOLING: UNIT SHALL BE CONTROLLED BY THE MANUFACTURER'S INTEGRAL THERMOSTAT.
WHEN THE SPACE TEMPERATURE RISES ABOVE THE COOLING SETPOINT (75°F), THE
THERMOSTAT SHALL ENERGIZE THE DSS UNITS AND ENERGIZE THE INDOOR UNIT SUPPLY
FAN. WHEN THE SPACE TEMPERATURE DROPS BELOW THE THERMOSTAT SETPOINT, THE
OPPOSITE SHALL OCCUR.
HEATING: UPON A FALL IN SPACE TEMPERATURE BELOW HEATING SETPOINT (68°F), THE
THERMOSTAT SHALL ENERGIZE THE INDOOR UNIT SUPPLY FAN AND OUTDOOR
COMPRESSORS. UPON A FURTHER DROP IN TEMPERATURE, THE UNITS ELECTRIC HEATING
COIL SHALL BE ENERGIZED. UPON A RISE IN SPACE TEMPERATURE ABOVE HEATING
SETPOINT, THE OPPOSITE SHALL OCCUR.
ALARM: SPACE TEMPERATURE SHALL BE MONITORED BY A SEPARATE TEMPERATURE
SENSOR. ALARM IF TEMPERATURE IS 78° F (ADJ.). UNIT CONTROL BY MANUFACTURER.
NO SCALE
DSS, CONTROL DIAGRAM (DDC)
SEQUENCE OF OPERATION
MANUFACTURER'S INTEGRAL
THERMOSTAT
RS/RLT
DUCTLESS SPLIT SYSTEM
LOCAL DDC CONTROLLER
A N
A L
O G
INPUTS
SPACE TEMPERATURE
AI1
AI1
TS
252.636.8778 (PHONE)
252.636.8992 (FAX)
WALKER
GROUP
i n c o r p o r a t e d the
ARCHITECTURE
DISCLOSURE OF INFORMATION
CONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO
THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR
(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE
(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE
FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE
PROPOSED DATE FOR RELEASE.
(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
01/24/2020
HEATING HOT WATER SYSTEM
GENERAL: THE HOT WATER SYSTEM SHALL BE CONTROLLED BY THE BOILER MANAGEMENT SYSTEM. CONTROLLER SHALL MONITOR BOILERS'
STATUS AND HOT WATER SUPPLY TEMPERATURES. BOILERS SHALL OPERATE IN LEAD/LAG CONFIGURATION AND THE PUMPS SHALL
OPERATE IN A LEAD/STAND-BY CONFIGURATION ALTERNATING LEAD BOILERS/PUMPS STATUS WEEKLY BY SELECTING BOILER/PUMP WITH THE
LEAST TOTAL ACCUMULATED RUN TIME (HOURS). SECONDARY PUMPS ARE SIZED FOR CONNECTED LOAD AND ARE FULLY REDUNDANT.
IF THERE IS AN ALARM IN ANY BOILER OR IF A FAULT OCCURS IN THE BOILER MANAGEMENT SYSTEM, (AS DETERMINED FROM THE BINARY
FAULT OUTPUT OF THE CONTROLLER), THE ASSOCIATED BOILER WILL BE COMMANDED OFF, AND AN ALARM SHALL BE GENERATED.
ON DETECTION OF A HIGH DISCHARGE BOILER TEMPERATURE, AS DETERMINED BY THE BOILER HIGH LIMIT ALARM, THE BOILER SHALL BE
DISABLED, AND AN ALARM SHALL BE GENERATED.
BOILER (B-1, B-2 ) AND PRIMARY HOT WATER PUMP CONTROL (RP-1, RP-2 ): ON A CALL FOR HEATING AT ANY AHU OR VAV TERMINAL FOR MORE
THAN THREE (3) MINUTES, THE DDC CONTROLLER SHALL SEND A SIGNAL TO THE BOILER MANAGEMENT SYSTEM THAT HEATING IS REQUIRED.
WHEN THE DDC CONTROL SYSTEM RECEIVES A CALL FOR HEATING, THE BOILER MANAGEMENT SYSTEM SHALL BE ENGAGED AND SHALL
ENABLE THE LEAD BOILER. THE LEAD BOILER AND ASSOCIATED PRIMARY HOT WATER PUMP SHALL BE ENERGIZED. UPON A DROP IN MAIN HW
LOOP TEMPERATURE BELOW SETPOINT, THE LAG BOILER AND ASSOCIATED PRIMARY HOT WATER PUMP SHALL BE ENERGIZED.
SECONDARY HOT WATER PUMPS, SHWP-1 AND SHWP-2: THE CONTROL STRATEGY INCLUDES OPERATING VARIABLE SPEED PUMPS IN ORDER
TO MINIMIZE PUMPING POWER REQUIREMENTS. THE SPEED DRIVE OF THE VARIABLE SPEED PUMP(S) IS CONTROLLED TO MAINTAIN A
DIFFERENTIAL PRESSURE SETPOINT. THE DDC CONTROLLER SHALL BE DESIGNED TO START AND STOP THE PUMPS AND MODULATE THEIR
SPEEDS AS REQUIRED TO MEET THE SYSTEM DEMANDS. THE SYSTEM SHALL BE DESIGNED TO MAINTAIN A DIFFERENTIAL PRESSURE
SETPOINT AT A REMOTE LOCATION.
SECONDARY HOT WATER PUMPS SHALL BE CONTROLLED BY THE DDC SYSTEM. PUMPS SHALL BE ENERGIZED AND RUN ON A CALL FOR
HEATING AT ANY AHU OR VAV TERMINAL FOR MORE THAN THREE (3) MINUTES. THE DDC CONTROLLER SHALL ALTERNATE PUMP LEAD
STATUS WEEKLY BY SELECTING THE PUMP WITH THE LEAST TOTAL ACCUMULATED RUN TIME AS CALCULATED AND STORED AT THE DDC
CONTROLLER. IF EITHER SELECTED LEAD PUMP'S PROOF SWITCH DOES NOT DETECT FLOW WITHIN 30 SECONDS FROM THE START SIGNAL, THE DDC CONTROLLER SHALL DE-ENERGIZE THE FAILED PUMP, START THE STANDBY PUMP, AND TRANSMIT A PUMP FAILURE ALARM. A
PROGRAMMED ANTI-RECYCLE TIMER SHALL PREVENT PUMP SHORT CYCLING. THE DDC CONTROLLER SHALL AUTOMATICALLY ATTEMPT A
RESTART OF THE CIRCULATING PUMPS ON A PERIODIC BASIS TO ACCOMMODATE SERVICE SHUTDOWNS AND EXTENDED POWER OUTAGES.
HOT WATER RESET CONTROL: THE SECONDARY HOT WATER SUPPLY TEMPERATURE SETPOINT SHALL BE DETERMINED BY THE OUTSIDE AIR TEMPERATURE. THE HOT WATER SUPPLY TEMPERATURE SETPOINT SHALL BE RESET PROPORTIONALLY AS FOLLOWS: AS AIR TEMPERATURE RISES
FROM 20°F TO 60°F, RESET SECONDARY HWS FROM 120°F DOWN TO 100°F.
BOILER EMERGENCY SHUT-OFF CONTROL: PROVIDE TWO POSITION "ON-OFF" SWITCHES LABELED "BOILER EMERGENCY SHUT-OFF" LOCATED
AS INDICATED WHICH SHALL BE HARDWIRE INTERLOCKED WITH THE BOILERS' CONTROL PANEL. WHEN INDEXED TO THE "ON" POSITION, THE
BOILERS SHALL OPERATE UNDER NORMAL CONTROL OF THE DDC CONTROL SYSTEM. WHEN INDEXED TO THE "OFF" POSITION, THE BOILERS
SHALL BE DISABLED, AND THE GAS BURNERS TO EACH BOILER SHALL BE SHUTDOWN. MANUAL RESET SHALL BE REQUIRED.
ALARMS: IF THERE IS AN ALARM IN ANY BOILER OR IF A FAULT OCCURS IN THE BOILER MANAGEMENT SYSTEM, (AS DETERMINED FROM THE
BINARY FAULT OUTPUT OF THE CONTROLLER), THE ASSOCIATED BOILER ISOLATION VALVE SHALL CLOSE, AND AN ALARM SHALL BE
GENERATED. ON DETECTION OF A HIGH DISCHARGE BOILER TEMPERATURE, AS DETERMINED BY THE BOILER HIGH LIMIT ALARM, THE BOILER
MANAGEMENT SYSTEM SHALL BE DISABLED AND AN ALARM SHALL BE GENERATED. ALARM FOR LEAVING WATER TEMPERATURE EXCEEDING
140°F OR FALLING 10°F BELOW THE SCHEDULED HWS TEMPERATURE SETPOINT. ALARM IF ANY BOILER OR PUMP FAILS TO START OR FAILS
DURING OPERATION.
DDC/EMCS SIGNAL-FUNCTION:
RETURN WATER TEMPERATURE - STATUS
LEAVING WATER TEMPERATURE - STATUS
PUMP RP-1 - START/STOP, STATUS, ALARM
PUMP RP-2 - START/STOP, STATUS, ALARM
PUMP SHWP-1 MOTOR - START/STOP, STATUS, RUNTIME, ALARM
PUMP SHWP-2 MOTOR - START/STOP, STATUS, RUNTIME, ALARM
DIFFERENTIAL PRESSURE SENSOR - PUMP SHWP-1 AND SHWP-2 VFD CONTROL
BOILER MANAGEMENT SYSTEM - ALARM, STATUS, START/STOP
EMERGENCY GAS SHUT OFF SWITCH - BOILER B - 1, 2, START/STOP, ALARM
BOILER CONDENSATE PUMP - ALARM
PHWS
BOILER
CONTROL
PANEL
PHWS
BOILER
B-1
AN
AL
OG
HWS TEMPERATURE
DIFFERENTIAL PRESSURE
DI
GI
TA
L
AN
AL
OG
OUTPUTS
DI
GI
TA
L
SHWP-1 SPEED CONTROL
SHWP-2 SPEED CONTROL
SHWP-1 VFD, ENABLE/DISABLE
BOILER, ENABLE/DISABLE
SHWP-2 VFD, ENABLE/DISABLE
BOILER ALARM
SHWP-2
SHWR HWR TEMPERATURE
INPUTS
LOCAL DDC CONTROLLER
HEATING HOT WATER SYSTEM
RP-1 - STATUS
RP-2 - STATUS
SHWP-1 - STATUS
SHWP-2 - STATUS
EMERGENCY SWITCH
BOILER MANAGEMENT SYSTEM
BOILER LOOP SUPPLY TEMPERATURE
B-1 SUPPLY TEMPERATURE
RP-1, ENABLE/DISABLE
BRIDGE
BOILER
B-2
B-2 SUPPLY TEMPERATURE
EMERGENCY GAS
SHUTOFF SWITCH
SHWP-1
HW FLOWRATE
SHWP-1 VFD SPEED (Hz)
SHWP-2 VFD SPEED (Hz)
RP-2, ENABLE/DISABLE
GAS, ON/OFF
AI1
AI2
AI3
AI4
AI5
AI6
AI8
AI9
AI10
DI1
DI2
DI3
DI5
DI6
AO1
AO2
DO1
DO2
DO3
DO4
DO5
DO1DI1
AI5
AI4
DI6
AI3 DPS
VFD
VFD
DPS
DPS
AI2 AI8
DI4
DI5
AI1
AO2DO3
DO2 AO1 SHWSSHWS
PH
W
R
AI9
AI10
AI7
DI4
DO6
TS
TS
TS FM
TS
ES
SEQUENCE OF OPERATION
SEE SHEET M-101 FOR LOCATION
LP
D06
M
DPS
DI2
DO4
RP-1
DPS
DI3
DO5
AI6TS
BOILER LOOP RETURN TEMPERATUREAI7 TS
RP-2
HEATING HOT WATER SYSTEM CONTROL DIAGRAM
SCALE: NO SCALE M-703A
3/4" COLD WATER, SEE PLUMBING
M-703 FOR CONTROLS SCHEMATIC (TYP.)
TEMPERATURE SENSOR AND WELL. SEE SHEET
ROOM WALL (TYP. FOR 2)
VALVE AT EQUIPMENT
TO BUILDING HW SYSTEM
SEE SHEET M-101 FOR CONTINUATION
ET-1
HWR
HWS
TANGENTIAL AIR
SEPARATOR
FLOOR DRAIN
1" TO
NEAREST
3/4"
PRESSURE REGULATION
RELIEF VALVE-
AIR VENT
SET AT 50 PSIG
VALVE-SET AT 26 PSIG
1" BYPASS
HWS
3/4"
SHWP-2
3/4"
(0-100 PSIG TYP.)
PRESSURE GAUGE
SHWP-1
2"
HIGH CAPACITY
2" 2"
2"
2"
LINE SIZE
REMOVE START-UP STRAINER
PRIOR TO TAB WORK (TYP.)
1/4"
1/4"
SHEETS FOR BACKFLOW PREVENTER,
AND CONTINUATION
4" CONCRETE
EQUIPMENT PAD (TYP.)
PH
W
S
PH
W
R
2"
RP-1
INLINE PUMP, SEE
DETAIL FOR VALVE
WORK REQUIRED
PH
W
R
PH
W
S
2"
2"
30 PSIG RELIEF VALVE BY
MANUFACTURER (TYP)
FULL SIZE OF OUTLET,
PIPE TO FLOOR DRAIN
(TYP)
B-2
3/4" DRAIN AND BALL
VALVE (TYP)
B-1
HWS
SHOT FEEDER
5 GALLON
HOT WATER FLOW DIAGRAM
SCALE: NO SCALE M-703B
1" 3/4"
CONDENSATE
NEUTRALIZATION KIT
BRIDGE
RP-2
TO FLOOR DRAIN
252.636.8778 (PHONE)
252.636.8992 (FAX)
WALKER
GROUP
i n c o r p o r a t e d the
ARCHITECTURE
DISCLOSURE OF INFORMATION
CONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO
THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR
(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE
(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE
FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE
PROPOSED DATE FOR RELEASE.
(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
LIGHTING FIXTURE
EXIT LIGHTING FIXTURE, WITH DIRECTIONAL ARROWS AS INDICATED WITH BATTERY
PACK - CONNECT AHEAD OF LOCAL SWITCH.
EMERGENCY BATTERY LIGHTING UNIT, CONNECT AHEAD OF LOCAL SWITCH.
LIGHTING FIXTURE TYPE SYMBOL. SEE LIGHTING FIXTURE DETAILS.
SINGLE POLE SWITCH, 20A, 120/277V, 46" AFF UON
EQUIPMENT CONNECTION
MOTOR CONNECTION
SAFETY SWITCH, 60A-3P, FU @ 30A, 3R
MAGNETIC MOTOR STARTER, MOUNT WITHIN SIGHT OF MOTOR 5'-0" AFF MAX,
UON.
ELECTRICAL PANELBOARD; 208/120V, 3Ø, 4W
ELECTRICAL CIRCUIT RUN IN CONDUIT AND CIRCUIT HOMERUN TO PANELBOARD
(PANEL AND CIRCUIT DESIGNATION AS INDICATED). AS A MINIMUM CONDITION, EACH
SINGLE PHASE CIRCUIT MUST HAVE 1 #12 PHASE CONDUCTOR, 1 #12 NEUTRAL
CONDUCTOR AND 1 #12 GROUNDING CONDUCTOR IN 1/2" CONDUIT. PROVIDE
ADDITIONAL PHASE CONDUCTORS AS REQUIRED FOR "MULTIPLE PHASED"
ELECTRICAL LOADS. PROVIDE NEUTRAL CONDUCTOR TO ALL WALL SWITCH OUTLET
BOXES WHETHER REQUIRED OR NOT. PROVIDE ADDITIONAL "SWITCH LEG"
CONDUCTORS TO PROVIDE THE LIGHT FIXTURE CONTROL INDICATED. MULTIPLE
SINGLE PHASE CONDUCTORS MAY BE GROUPED TOGETHER IN A COMMON CONDUIT
IN ACCORDANCE WITH THE NEC AND AT THE CONTRACTOR'S DISCRETION.
GROUNDING CONDUCTORS MAY BE SHARED AS ALLOWED BY THE NEC. NEUTRAL
CONDUCTORS MUST NOT BE SHARED. MULTI-POLE BREAKERS MUST BE PROVIDED IN
ACCORDANCE WITH THE NEC WHERE MULTI-WIRE BRANCH CIRCUITS ARE REQUIRED.
CONDUIT LARGER THAN 1/2" AND CONDUCTORS LARGER THAN #12 MUST BE AS
INDICATED.
LIGHTING
POWER
GENERAL
WALL MOUNTED LIGHTING FIXTURE
NEW WORK NOTE SYMBOL
MOTOR RATED SWITCH WITH THERMAL OVERLOADS 20A, 120V, UON, MOUNTED
WITHIN SIGHT OF MOTOR.
PHOTOCELL, 1500W, 120V SPST, MOUNT ON ROOF, AIM NORTH
PAD MOUNTED TRANSFORMER
INDICATES FRONT
SURGE PROTECTIVE DEVICE
GENERAL: UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL WORK SHOWN ON
ELECTRICAL DRAWINGS IS NEW WORK TO BE PROVIDED UNDER THIS CONTRACT.
COORDINATION: COORDINATE AND COOPERATE WITH ALL TRADES ON THE
PROJECT. THE CONTRACTOR MUST REVIEW ALL CONTRACT DOCUMENTS
INCLUDING CIVIL, STRUCTURAL, ARCHITECTURAL DRAWINGS AND
SPECIFICATIONS. CONTRACTOR MUST COORDINATE AND ADJUST ACCORDINGLY
AS DIRECTED BY THE CONTRACTING OFFICER.
AS-BUILT DRAWINGS: SECURE AN EXTRA SET OF ELECTRICAL DRAWINGS TO BE
KEPT ON SITE AND MARK, DAILY, THE DRAWINGS IN RED AS THE PROJECT
PROGRESSES IN ORDER TO KEEP AN ACCURATE RECORD OF ALL DEVIATIONS
BETWEEN THE WORK SHOWN ON THE DRAWINGS AND THE WORK WHICH IS
ACTUALLY INSTALLED. THESE MARKED DRAWINGS MUST REFLECT ANY AND ALL
CHANGES AND REVISIONS TO THE ORIGINAL DESIGN WHICH EXISTS IN THE
COMPLETED WORK. DELIVER THE MARKED DRAWINGS TO THE ENGINEER AT
PROJECT CLOSE-OUT.
TESTS: TEST ALL WIRING FOR CONTINUITY AND GROUNDS BEFORE CONNECTING
ANY FIXTURES OR DEVICES. PERFORM INSULATION RESISTANCE TESTS ON ALL
WIRING #6 OR LARGER TO ENSURE THAT ALL PORTIONS ARE FREE FROM
SHORT-CIRCUITS AND GROUNDS.
INSPECTIONS: ARRANGE ALL NECESSARY INSPECTIONS. DELIVER ALL REQUIRED
INSPECTION CERTIFICATES TO THE CONTRACTING OFFICER.
ELECTRICAL SERVICE: PROVIDE THE ELECTRICAL SERVICE. COMMUNICATE WITH
THE CONTRACTING OFFICER, VERIFY ALL REQUIREMENTS, AND COORDINATE ALL
EFFORTS.
GROUNDING: PROVIDE GROUNDING IN ACCORDANCE WITH THE NEC FOR THE
ENTIRE ELECTRICAL SYSTEM INCLUDING EQUIPMENT FRAMES CONDUITS,
SWITCHES, CONTROLLERS, WIRE-WAYS, NEUTRAL CONDUCTORS, AND OTHER
EQUIPMENT. PROVIDE A GROUNDING CONDUCTOR IN ALL POWER CONDUITS.
LABELS: PROVIDE LABELS FOR ALL PANELBOARDS, SAFETY SWITCHES,
MOTOR-DISCONNECT SWITCHES, AND MOTOR CONTROLLERS. LABELS MUST BE
MACHINE ENGRAVED, LAMINATED PLASTIC, PERMANENTLY ATTACHED WITH
SELF-TAPPING SCREWS OR RIVETS. DO NOT USE SELF-ADHESIVE LABELS. LABEL
MUST INDICATE EQUIPMENT DESIGNATION AND ASSOCIATED PANEL AND CIRCUIT
THAT SERVES IT.
J-BOX LABELING: LABEL ALL JUNCTION BOXES WITH PERMANENT MARKER
IDENTIFYING CIRCUIT NUMBER AND PANELBOARD OF CIRCUITS WITHIN.
WIRING DEVICES: LABEL ALL WIRING DEVICES WITH PANELBOARD AND CIRCUIT
DESIGNATION PERMANENTLY ATTACHED WITH BLACK TYPED DESIGNATION ON
CLEAR TAPE.
PANEL DIRECTORY: PROVIDE TYPEWRITTEN PANELBOARD DIRECTORY CARD IN
EACH PANELBOARD WITH CIRCUIT LOAD INFORMATION AND ROOM NUMBER
CLEARLY IDENTIFIED. USE ACTUAL ROOM NUMBERS IN THE BUILDING, NOT THE
ROOM NUMBERS SHOWN ON THE CONTRACT DRAWINGS, AS THEY ARE OFTEN
DIFFERENT.
CONDUCTORS AND MATCHING LUGS: IN SITUATIONS WHERE CONDUCTOR SIZES
AND/OR QUANTITIES OF PARALLEL SETS HAVE BEEN INCREASED DUE TO
VOLTAGE DROP OR FOR OTHER REASONS, CONTRACTOR MUST PROVIDE THE
APPROPRIATE LUG SIZES/QUANTITIES WITHIN THE EQUIPMENT CONNECTED
(SWITCHBOARD, PANELBOARD, DISCONNECT SWITCH, TRANSFER SWITCH ETC.)
TO PERMIT SATISFACTORY CONNECTION OF THE INDICATED CONDUCTORS.
WHERE SUFFICIENT LUG SIZES AND/OR QUANTITIES CANNOT BE PROVIDED TO
ACCOMMODATE THE CONDUCTORS INDICATED, THEN PROVIDE REDUCING
ADAPTERS, PIN TERMINALS, OR A JUNCTION BOX TO SPLICE LARGER
CONDUCTORS TO APPROPRIATELY SIZED SMALLER CONDUCTORS TO FIT INTO
THE LUGS PROVIDED. ALL CONDUCTORS MUST BE SIZED IN ACCORDANCE WITH
THE NEC.
MOTOR COORDINATION: MOTORS, MOTOR STARTERS, CONTROLLERS, INTEGRAL
DISCONNECT SWITCHES, AND CONTACTORS MUST BE PROVIDED WITH THEIR
RESPECTIVE PIECES OF EQUIPMENT BY THE EQUIPMENT SUPPLIER.
COMMUNICATE WITH THE TRADES PROVIDING THE EQUIPMENT, VERIFYING ALL
REQUIREMENTS, PROVIDE ALL ELECTRICAL CONNECTIONS REQUIRED THEREIN,
AND INSTALL MOTOR STARTERS.
MOTOR DISCONNECTS: ALL MOTORS MUST HAVE DISCONNECTING MEANS.
MOTOR CONTROLLERS: ALL 3-PHASE MOTORS MUST HAVE MAGNETIC MOTOR
CONTROLLERS WITH SOLID STATE OVERLOAD RELAY PROTECTION. THE SOLID
STATE OVERLOAD RELAY MUST HAVE PHASE LOSS AND PHASE OVERCURRENT
PROTECTION WITH AUTOMATIC RESET UPON RETURN OF NORMAL POWER.
MOTOR FUSE PROTECTION: WHERE FUSE PROTECTION IS SPECIFICALLY
REQUIRED BY THE EQUIPMENT MANUFACTURER, PROVIDE FUSED SWITCHES IN
LIEU OF NON-FUSED SWITCHES OR IN LIEU OF ENCLOSED CIRCUIT BREAKERS, OR
OTHER DEVICES INDICATED.
CONNECTION DETAILS: SECURE APPROVED SHOP DRAWINGS SHOWING WIRING
DIAGRAMS, ROUGH-IN AND HOOK UP DETAILS FROM OTHER INVOLVED
CONTRACTORS FOR EQUIPMENT WHICH MUST BE CONNECTED ELECTRICALLY.
COORDINATION DETAILS: MECHANICAL EQUIPMENT WILL BE FURNISHED AND
INSTALLED BY THE MECHANICAL CONTRACTOR. THE LOCATIONS SHOWN ON THE
ELECTRICAL DRAWINGS ARE APPROXIMATE. COORDINATE WITH THE
MECHANICAL CONTRACTOR TO DETERMINE THE EXACT LOCATION OF EACH
PIECE OF EQUIPMENT AND DETERMINE THE EXACT ROUGH-IN AND CONNECTION
REQUIREMENTS.
WORKING CLEARANCE: COORDINATE FINAL LOCATIONS OF ELECTRICAL
EQUIPMENT WITH MECHANICAL DUCTWORK, PIPING ETC. AND ASSURE WORKING
CLEARANCE REQUIRED BY NEC WILL BE MET. SUFFICIENT ACCESS AND WORKING
SPACE MUST BE PROVIDED AND MAINTAINED AROUND ELECTRICAL EQUIPMENT
AS REQUIRED BY THE NATIONAL ELECTRICAL CODE. CONTRACTOR MUST
COORDINATE FINAL LOCATION OF EQUIPMENT PROVIDED AND INSTALLED BY
OTHER TRADES.
STARTER MOUNTING: WHERE AN INDIVIDUALLY MOUNTED SAFETY SWITCH,
STARTER OR CIRCUIT BREAKER IS SHOWN ADJACENT TO ITS RESPECTIVE LOAD
AND NOT MOUNTED ON A WALL, PROVIDE ALL SUPPORTS, BRACKETS,
ANCHORING, ETC. NECESSARY TO PROPERLY SUPPORT THE DEVICE.
LIGHTING ARRANGEMENT: ARRANGE LIGHTING FIXTURES IN ACCORDANCE WITH
THE ARCHITECTURAL REFLECTED CEILING PLANS.
LIGHTING COORDINATION: COORDINATE LIGHTING FIXTURES WITH GRILLES,
DIFFUSERS, SPRINKLER HEADS, AND ACCESS PANELS, ETC. PROVIDE FIXTURE
MOUNTING BRACKETS, ACCESSORIES, PLASTER FRAMES, ETC.. SUITABLE FOR
THE CEILING TYPES INDICATED ON THE ARCHITECTURAL PLANS.
LIGHTING CONTROL TESTING: UPON COMPLETION OF THE INSTALLATION OF ALL
LIGHTING SYSTEMS AND CONTROL DEVICES, CONTRACTOR MUST CONFIRM
PROPER OPERATION OF ALL LIGHTING CONTROLS, AND DEMONSTRATE PROPER
OPERATION TO THE CONTRACTING OFFICER.
MATERIAL COORDINATION: VERIFY CEILING AND WALL CONSTRUCTION AND
MATERIAL PRIOR TO ORDERING LIGHT FIXTURES OR OTHER DEVICES TO INSURE
PROPER FIXTURE OR DEVICE IS FURNISHED TO MATCH CONSTRUCTION.
MOUNTING HEIGHTS: MOUNTING HEIGHTS INDICATED ARE FROM THE FINISHED
FLOOR TO THE CENTERLINE OF THE WIRING DEVICE UNLESS OTHERWISE NOTED.
MOUNTING HEIGHTS OF LIGHTING FIXTURES ARE TO THE BOTTOM OF THE
FIXTURE UNLESS OTHERWISE NOTED.
DEVICE LOCATIONS: COORDINATE LOCATIONS OF SWITCHES, RECEPTACLES,
AND TELE/DATA OUTLETS WITH OTHER WALL MOUNTED DEVICES SUCH AS
THERMOSTATS AND CONTROL STATIONS.
MULTI-GANG JUNCTION BOXES: WHERE OUTLETS AND SWITCHES ARE SHOWN
ON PLAN TO BE INSTALLED ADJACENT TO EACH OTHER AND AT THE SAME
MOUNTING HEIGHT, THE DEVICES MUST BE INSTALLED IN A MULTI-GANG
OUTLET BOX, UON. THE SIZE OF THE OUTLET BOX MUST BE DETERMINED BY
THE NUMBER OF DEVICES AND CONDUCTORS THAT MUST BE INSTALLED IN
THE MULTI-GANG OUTLET BOX.
FIRE STOPPING: FOR ANY WALL PENETRATIONS THROUGH FIRE-RATED
STRUCTURES PROVIDE FIRE-STOPPING TO SEAL ALL THE PENETRATIONS AFTER
THE CONDUIT HAS BEEN INSTALLED. FIRE STOPPING FOR PENETRATIONS MUST
BE UL APPROVED PER THE PENETRATION MADE IN ORDER TO MAINTAIN
FIRE-RATED INTEGRITY OF THE STRUCTURE.
CLEAN UP: ON PROJECT CLOSE-OUT CLEAN ALL ELECTRICAL DEVICES, LIGHTING
FIXTURES, LENSES, AND REMOVE ALL PAINT SPATTERS FROM DEVICES,
FIXTURES AND PLATES. REPAIR ALL INOPERATIVE LIGHTING FIXTURES.
GROUND FAULT PROTECTION: RECEPTACLES LOCATED WITHIN 6'-0" OF THE
EDGE OF SINKS MUST BE PROVIDED WITH GROUND FAULT PROTECTION
WHETHER SHOWN OR NOT.
HVAC DAMPERS, ETC: CONTRACTORS MUST COORDINATE WITH THE EQUIPMENT
AND SYSTEM BEING PROVIDED AND PROVIDE POWER CONNECTIONS
ACCORDINGLY. THESE CONNECTIONS MUST BE FOR FIRE/SMOKE DAMPERS, DDC
CONTROL DEVICES, ETC. CONTRACTOR MUST COORDINATE THE VOLTAGE
REQUIREMENTS AND PROVIDE ALL NECESSARY CONNECTIONS, COMPONENTS,
ETC. THIS INCLUDES TRANSFORMERS, BOXES, ETC.
THE FOLLOWING SUBSCRIPTS MUST APPLY TO RECEPTACLES WHERE USED:
CONTRACTOR MUST PROVIDE AN APPROPRIATE LISTED THROUGH-PENETRATION FIRE STOPPING ASSEMBLY AT EACH PENETRATION OF FIRE RATED CONSTRUCTION (I.E. WALLS AND SLABS, ETC.). SLEEVES MUST ONLY BE PERMITTED WHERE INDICATED IN THE CONTRACTOR SELECTED THROUGH-PENETRATION FIRE STOPPING ASSEMBLY. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF ALL RATED ASSEMBLIES AND ASSOCIATED UL DESIGNATIONS. DEVICES INSTALLED RECESSED WITHIN FIRE RATED CONSTRUCTION (I.E. LIGHT SWITCHES, RECEPTACLES, ETC.) ARE ONLY PERMITTED WHEN AN APPROVED LISTED FIRE STOPPING SYSTEM EXISTS FOR THE APPLICATION. IF AN APPROVED LISTED FIRE STOPPING SYSTEM IS UNAVAILABLE, THE CONTRACTOR MUST BRING THE CONDITION TO THE ATTENTION OF THE A/E FOR RESOLUTION PRIOR TO PROCEEDING WITH WORK.
FIRE STOPPING NOTE:
AND
SWITCH RATING
NUMBER OF POLES
FUSE RATING (NF INDICATES NON-FUSED)
NEMA ENCLOSURE IF OTHER THAN NEMA 1
SPD
T
A
P
E
M
DUPLEX CONVENIENCE RECEPTACLE 20A, 120V, 18" AFF, UON
TWO DUPLEX RECEPTACLES IN COMMON BOX, EACH 20A, 120V, 46" AFF, UON
DUPLEX CONVENIENCE RECEPTACLE 20A, 120V, 46" AFF, UON (OR 6" ABOVE
COUNTER AS APPLICABLE)
· GFI: GROUND FAULT INTERRUPTING TYPE RECEPTACLE
· +XX": DEVICE MOUNTING HEIGHT DESIGNATION ABOVE FINISHED FLOOR IF OTHER
THAN 18" OR 46".
· WP: WEATHER RESISTANT GFI RECEPTACLE WITH WEATHERPROOF WHILE-IN-USE
COVER.
ABBREVIATIONS
A AMPERE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC AMPERE INTERRUPTING CAPACITY
BFG BELOW FINISHED GRADE
C CONDUIT
CKT CIRCUIT
CB CIRCUIT BREAKER
DDC DIRECT DIGITAL CONTROL
EBU EMERGENCY BATTERY UNIT
EC EMPTY CONDUIT
EF EXHAUST FAN
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWH ELECTRIC WATER HEATER
EXIST EXISTING
FLA FULL LOAD AMPS
GFI GROUND FAULT INTERRUPTER
GND GROUND
HP HORSE POWER/HEAT PUMP
KAIC THOUSAND AMPERE
INTERRUPTING CAPACITY
KVA KILO-VOLT-AMPERES
KW KILO-WATTS
LTG LIGHTING
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MIN MINIMUM
MLO MAIN LUGS ONLY
MTD MOUNTED
NEC NATIONAL ELECTRICAL CODE
NF NON-FUSED
NTS NOT TO SCALE
P POLE
PNL PANEL
PNLBD PANELBOARD
Ø PHASE
PRI PRIMARY
RECEPT RECEPTACLE
SE SERVICE ENTRANCE
SEC SECONDARY
SPD SURGE PROTECTION DEVICE
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V VOLT
W WATTS/WIRE
WP WEATHERPROOF
REMOTE EMERGENCY BATTERY LIGHTS
WATTHOUR DEMAND METER: TO CONFORM TO BASE
STANDARDS. ITRON V&I CS3 SERIES METER.
METER NOTE:
FIRE ALARM/MASS NOTIFICATION CONTROL PANELFAMN
OVERHEAD DOOR CONTROL STATION (UP/STOP/DOWN), MOUNT 46" AFF.
VFD
FIRE ALARM TRANSMITTERFAT
THREE-WAY SWITCH, 20A, 120/277V, 46" AFF UON3
VACANCY SWITCH, 20A, 120/277V, 46" AFF UONV
DIMMER SWITCH, 0-10VDC, 46" AFF UOND
THREE-WAY DIMMER SWITCH, 0-10VDC, 46" AFF UOND3
01/24/2020
ChrisLife
E
O
P
EOP 7.2
EOP 7.2
E
O
H
S
EO
P 1
2.4
E O
P
E O
P
E
O P
E O
P
E O
P
.2
E O
P
.2
EOP 7.2
EOP 7.2
EXISTING POLE
UG TERM (15KV)
CONDUIT RISER (6" PVC)
GROUND
U S
T
U S
X
X
X
X
X
X
X
X
MDP
UP
UP
UP
UP
SPARE
PRIMARY IN DUCT
SPARE
SECONDARY
IN DUCT
HH
The Walker Group Architecture, Inc PO Box 541, New Bern, NC 28563
252.636.8778 (PHONE)
252.636.8992 (FAX)
WALKER
GROUP
i n c o r p o r a t e d the
ARCHITECTURE
DISCLOSURE OF INFORMATION
CONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO
THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR
(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE
(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE
FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE
PROPOSED DATE FOR RELEASE.
(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
TN
PN
SITE PLAN
SCALE: 1" = 10'-0"
10'
1" = 10'-0"
20'10'5'0'
US
UP
UNDERGROUND SECONDARY CIRCUIT
UNDERGROUND PRIMARY CIRCUIT
E12.47 EXISTING OVERHEAD PRIMARY CIRCUIT; 12.47 KV
ALUMINUM, BARE, 6201 ALLOY, 19 STRAND, 394.5 KCMIL, CODE
NAME CANTON
PAD MOUNTED TRANSFORMER
FRONT
T
TAP EXISTING OVERHEAD PRIMARY LINE, PROVIDE OVERHEAD TO
UNDERGROUND TRANSITION AND EXTEND PRIMARY TO PAD MOUNTED
TRANSFORMER. SEE POLE PHOTO THIS SHEET.
CUT AND PATCH ROAD AS REQUIRED FOR UNDERGROUND, CONCRETE
ENCASED DUCT.
EXISTING POLE
EOP 7.2 EXISTING OVERHEAD PRIMARY, 7.2 KV, SINGLE PHASE TO REMAIN
PANELBOARD - 208/120V, 3 PHASE, 4 WIRE
NOT TO SCALE
PAD MOUNTED
TRANSFORMER: 225 KVA,
12.47 KV TO 208/120 V, 3
PHASE, 4 WIRE
E12.47
U P
3 #2 EPR 15KV & 1 #2 COPPER NEUTRAL IN 5" PVC
CONDUIT AND ONE 5" PVC SPARE CONDUIT
CONCRETE ENCASED. SEE CONCRETE ENCASED
DUCTBANK - DETAIL 'A' SHEET ES502.
FUSED CUTOUTS: 100A
REMOVE EXISTING POLE MOUNTED TRANSFORMER, GUY AND
OVERHEAD SECONDARY TO EXISTING BUILDING BEING
DEMOLISHED. SEE POLE PHOTO THIS SHEET.
REMOVE EXISTING DIRECT BURIED, WOOD POLE.
REMOVE EXISTING DIRECT BURIED, WOOD POLE AND OVERHEAD
SERVICE DROP TO BUILDING BEING DEMOLISHED.
NOT TO SCALE
EOP 7.2 REMOVE EXISTING OVERHEAD PRIMARY, 7.2 KV, SINGLE PHASEX X
EXISTING POLE MOUNTED TRANSFORMER
EXISTING POLE GUY
POLE MOUNTED SURGE ARRESTOR WITH GROUND.
EXISTING STREET LIGHT
TO REMAIN
EOHS EXISTING OVERHEAD SECONDARY TO REMAIN
HANDHOLE, TYPE 1.
HH
252.636.8778 (PHONE)
252.636.8992 (FAX)
WALKER
GROUP
i n c o r p o r a t e d the
ARCHITECTURE
DISCLOSURE OF INFORMATION
CONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO
THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR
(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE
(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE
FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE
PROPOSED DATE FOR RELEASE.
(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
POLE LINE MATERIAL LIST
FLAT STEEL BRACE (TWO PIECES)
MACHINE BOLT, 3/8" X LENGTH NEEDED WITH WASHER, NUT AND LOCKWASHER
8' WOOD CROSSARM WITH CROSS SECTION DIMENSIONS OF 3 1/2" X 4 1/2"
MACHINE BOLT, 5/8" X LENGTH NEEDED WITH WASHER, NUT AND LOCKWASHER
TIMBER CONNECTOR
LAGSCREW, 1/2" X 4"
ANGLE STEEL BRACE (TWO PIECES)
MACHINE BOLT, 1/2" X LENGTH NEEDED, WITH WASHER, NUT & LOCKWASHER
DEADEND BOX
STEEL PIN
PIN INSULATOR
GRID GAIN, USED ONLY WHEN THERE IS NO POLE GAIN
ANGLE STEEL BRACE (ONE PIECE)
10' WOOD CROSSARM WITH CROSS SECTION DIMENSIONS OF 3 1/2" X 4 1/2"
5/8" EYE NUT
5/8" EYE BOLT, LENGTH AS NEEDED, WITH WASHER, NUT & LOCKWASHER
EXTENSION LINK
BELL TYPE SUSPENSION INSULATOR WITH CONNECTING HARDWARE
STRAIN CLAMP
STEEL ANGLE PIN
CLUSTER MOUNTING BRACKET, STEEL
TRANSFORMER GROUNDING CONNECTION
STIRRUP
SECONDARY LEAD SUPPORT BRACKET
ADAPTER PLATE FOR CLUSTER MOUNTING
CLEVIS BRACKET FOR SPOOL INSULATOR
SPOOL INSULATOR
U BOLT CLAMP
PREFORMED GUY GRIP
GUY HOOK
GUY STRAIN INSULATOR
GUY WIRE, SIZE AS SPECIFIED
#4 WP CU. SOFT DRAWN GROUND WIRE
GROUND CLAMP
CONDUIT COUPLING
CONDUIT BEND
INSULATED BUSHING
PERFORATED STRAPPING, 1-1/2" WIDE
HOT LINE CLAMP
FUSED CUTOUT, AS SPECIFIED
SURGE ARRESTER, AS SPECIFIED
POLE TOP PIN (RIDGE PIN) - 24 INCHES LONG
CROSSARM ANGLE PIN
ANGLE POLE TOP PIN
WEATHERPROOF SOFT DRAWN WIRE-SIZE
T0 MATCH OR EXCEED AMPACITY OF CONNECTING
CABLE, OR
AT 125% OF TRANSFORMER FULL LOAD
CURRENT, BUT NOT LESS THAN NO. 4 AWG
(a)
(b)
OH-1.5
JUNE 2002SKETCH DATE STYLE
POLE LINE MATERIAL LIST
UNDERBUILD CIRCUIT
POSITION OF COMMON NEUTRAL
OR MULTIPLEX SECONDARY
CONDUCTOR
CIRCUIT
COMM.
PROVIDE 60" CLEARANCE WHEN OPERATING VOLTAGE OF UNDERBUILD
CIRCUIT IS GREATER THAN 15KV.
NOTE
FOR HORIZONTAL SPACING REQUIREMENTS FOR CONDUCTORS ON SAME SUPPORT,
REFER TO THE NATIONAL ELECTRICAL SAFETY CODE, IEEE C2.
1.
Ø-Ø VOLTAGE 0-15KV 15-50KV
SPACING A"
SPACING B"
40"
40"
48"
40"
OH-1.4
JUNE 2002SKETCH DATE STYLE
BASIC VERTICAL SPACING REQUIREMENTS
"B"
"A"
40" MIN.
DEDICATED
CLEAR SPACE
POSITION OF LOWEST POWER (SUPPLY)
ATTACHMENT SHALL BE NO LESS THAN
24'-4" ABOVE GRADE.
DEDICATED CLEAR SPACE BETWEEN
POWER (SUPPLY) AND COMMUNICATION
CIRCUITS.
POSITION OF HIGHEST
COMMUNICATION ATTACHMENT
SHALL BE NO HIGHER THAN
21'-0" ABOVE GRADE.
EXPLANATION OF SYMBOLS LISTED FOR POLE ON SKETCH OH-1.3
EXPLANATORY NOTES - METHOD OF SHOWING SYMBOLS
SYMBOLS ARE SHOWN IN THE BASIC ORDER AS THEY APPEAR ON THE
POLE, BY STARTING AT THE TOP AND WORKING DOWN.
NUMERALS PRECEDING THE SYMBOL INDICATE THE MINIMUM REQUIRED
VOLTAGE (KV) RATING (5,15,35) OF THE ASSEMBLY, IF APPLICABLE.
NUMERAL FOLLOWING THE SYMBOL INDICATES THE NUMBER OF CON-
DUCTORS ASSOCIATED WITH THE ASSEMBLY, IF APPLICABLE.
NUMERAL IN PARENTHESIS FOLLOWING THE SYMBOL DENOTES THE
NUMBER OF ASSEMBLIES REQUIRED, IF MORE THAN ONE.
DATA IN PARENTHESIS FOLLOWING THE SYMBOL PROVIDES
INFORMATION RELATIVE TO THE SYMBOL.
1.
2.
3.
4.
5.
PROVIDE 45 FOOT LONG, CLASS 3 POLE CONTAINING:
TF -
S1 -
SDE2 -
GROUND -
X-FB -
35FR3 -
X-FB -
15F3 -
8' CROSSARM WITH FLAT BRACE
35KV INSULATORS, FLAT (MOUNTED HORIZONTAL ON CROSS-
ARM), RIDGE PIN (CENTER PHASE ON POLE TOP PIN), THREE
CONDUCTORS
8' CROSSARM WITH FLAT BRACE
15KV INSULATORS, FLAT (MOUNTED HORIZONTAL ON CROSSARM),
THREE CONDUCTORS. NOTE: THIS SYMBOL CALLS FOR THREE
CROSSARM MOUNTED PINS IN LIEU OF RIDGE PIN ON CENTER
PHASE.
TRANSFORMER ON FLAT (HORIZONTAL) CONSTRUCTION. DATA
IN PARENTHESIS DESCRIBES THE TRANSFORMER CHARACTERISTICS.
GUY (5/16") -
SECONDARY, ONE CONDUCTOR, TANGENT CONSTRUCTION (COMMON
NEUTRAL).
SECONDARY DEADEND, TWO CONDUCTORS, OPEN WIRE
DOWN GUY - WIRE SIZE 5/16"
10" SCREW TYPE ANCHOR WITH 12 FT. GUY LEAD.
NOTE: NO PLATE IS INCLUDED FOR THE ANCHOR SYMBOL.
NO EXPLANATION NECESSARY
ANCHOR -
(10" SCREW)
OH-1.3A
JUNE 2002SKETCH DATE STYLE
EXPLANATION OF NOTES/SYMBOLS
13.2
34.5
S
N
13.2
N
34.5
PLAN VIEW
POLE # (45'-3)
X-FB, 35FR3
X-FB, 15F3
TF (25KVA, 13.2 GRD. Y/7.6 KV - 120/240 V.)
S1, SDE2
GUY (5/16")
ANCHOR (10" SCREW) (12' GUY LEAD)
GROUND
NOTES
THE SYMBOLS LISTED ABOVE
INCLUDE MATERIALS (DESCRIBED
BY OVERHEAD SKETCHES) WHICH
ARE GRAPHICALLY ILLUSTRATED
BY THIS PICTURE. SEE
SKETCH OH-1.3A FOR
EXPLANATORY NOTES.
EACH SKETCH CONTAINS
MATERIAL ITEMS WHICH COMPRISE
A PART OF EACH INDIVIDUAL
SYMBOL REFERENCED BY THAT
SKETCH, THESE ITEMS ARE
INDICATED BY CIRCLED
NUMERALS WHICH ARE IDENTIFIED
BY SKETCHES OH-1.5
AND OH-1.5A.
SPACING REQUIREMENTS RELATED
TO INDIVIDUAL COMPONENTS OF
A SYMBOL ARE INDICATED ON
THE APPROPRIATE SKETCH.
VERTICAL SPACING
REQUIREMENTS BETWEEN
CIRCUITS AND/OR SYSTEMS
ARE INDICATED ON SKETCH
OH-1.4. ALL OTHER
SEPARATIONS BETWEEN
CIRCUITS, EQUIPMENT, ETC.,
SHALL CONFORM TO THE
NATIONAL ELECTRICAL
SAFETY CODE, IEEE C2.
1.
2.
3.
OH-1.3
JUNE 2002SKETCH DATE STYLE
METHOD OF SHOWING SYMBOLS
POLE LINE MATERIAL LIST
TRI-MOUNT BRACKET
TERMINATOR
MOUNTING BRACKET
CABLE GRIP HANGER
HOSE CLAMP
STUD, 3/4" X 1-3/4"
LINE POST INSULATOR
TRIPLE INSULATOR BRACKET
ANGLE CLAMP
INSULATOR, LINE POST CLAMP
4' CROSSARM
CROSSARM GAIN BRACKET
PULLEY BRACKET
WEDGE CLAMP
MIDSPAN SERVICE CLAMP
STUD, 7"
SADDLE, ANGLE
SADDLE CROSSARM
FITTING, POLE TOP
CONNECTOR
SUSPENSION CLAMP
TIE, SERVICE CABLE
54" FIBERGLASS STRAIN INSULATOR
69 PVC RISER SHIELD
PVC EXTENSION SHIELD
PVC BACK PLATE
8' WOOD CROSSARM WITH CROSS SECTION DIMENSIONS OF 4 3/4" X 5 3/4"
10' WOOD CROSSARM WITH CROSS SECTION DIMENSIONS OF 4 3/4" X 5 3/4"
OH-1.5A
JUNE 2002SKETCH DATE STYLE
POLE LINE MATERIAL LIST
BACK-UP CURRENT LIMITING FUSE
ATTACHMENT
POSITION OF GUY
SEE NOTE 3
SIDE VIEW
FRONT VIEW
THIS POLE.
CONTINUES ON BEYOND
NEUTRAL LEVEL, IF
POLE
DEADENDS ON THE
NEUTRAL LEVEL, IF
NOTES
1.
2.
3.
23 39
41 48
41 48
16"
2"
4"
40"
21"
24"
19"
36"
OH-31
JUNE 2002
(0-25KV)
U.G. TERMINAL
SKETCH DATE STYLE
MODIFY POSITION OF TERMINAL ON DEADENDS TO BE UNDER THE CONDUCTORS AND THE CUTOUTS ON THE BACKSIDE OF
CROSSARM. POLE RISER MUST BE OFFSET TO CLEAR NEUTRAL CLEVIS BRACKET.
CONNECT BOTTOM LEAD OF ARRESTER DIRECTLY TO POLE GROUND. INTERCONNECT CABLE INSULATION SHIELD
DRAIN WIRES AND CONDUIT RISER GROUND TO MULTI- GROUNDED NEUTRAL (IF EXISTING) AND POLE GROUND.
CUTOUT PROVIDES A FUSE OR A SOLID BLADE (NON-FUSED) OPTION. COORDINATE
WITH SPECIFIC DESIGN REQUIREMENTS PROVIDED.
252.636.8778 (PHONE)
252.636.8992 (FAX)
WALKER
GROUP
i n c o r p o r a t e d the
ARCHITECTURE
DISCLOSURE OF INFORMATION
CONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO
THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR
(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE
(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE
FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE
PROPOSED DATE FOR RELEASE.
(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
ROAD SIDE
DIRECTION
OF TRAFFIC
ADDITIONAL
GROUND RODS
(WHEN REQUIRED)
PLAN
ALWAYS CONNECT THE POLE GROUND
LEAD(S) DIRECTLY TO THE NEUTRAL-
ENSURE THAT THE COPPER CONDUCTOR
WILL ALWAYS BE BELOW THE ALUMINUM.
CONNECTOR
NEUTRAL
COPPERWELD STAPLES (TYP.)
GROUND
WIRE
POLE
ELEVATION
GROUND ROD
PLASTIC OR FIBER MOLDING
GALVANIZED STAPLES (TYPICAL)
FINISHED
GRADE
#4 BARE
COPPER
POLE
OH-41
JUNE 2002SKETCH DATE STYLE
GROUND
24"
MIN.
10'-0"
MIN.
10'-0"
MIN.
24"
12"
8'-0"
MIN.
18"
MAX.
8'-0 MIN.
(FROM 24'-4"
TO 16'-4"
ABOVE GRADE)
ALTERNATE GROUND WIRE
POSITION. (USE WHEN
MULTIPLE GROUNDING
SYSTEMS ARE REQUIRED.)
(SEE NOTE 4)
1.
2.
3.
NOTES
USE ADDITIONAL GROUND RODS, WHEN REQUIRED,
TO OBTAIN RESISTANCE VALUE, AS REQUIRED BY
IEEE C2.
MAKE GROUNDING CONNECTIONS TO ALL EQUIPMENT
ON POLE AS REQUIRED BY IEEE C2.
FOR SYSTEMS OTHER THAN 4 WIRE, MULTI-
GROUNDED, USE SEPARATE GROUNDING
CONDUCTORS AND ELECTRODES FOR PRIMARY
AND SECONDARY SYSTEM DEVICE CONNECTIONS.
#4 600V INSULATED COPPER GROUNDING
CONDUCTOR REQUIRED ON PRIMARY SYSTEM
WHEN SEPARATE SYSTEMS ARE REQUIRED.
4.
AF-1
APRIL 2015
GENERAL ARC FLASH WARNING LABEL
SKETCH DATE STYLE
NOTES:
1. PROVIDE SELF-ADHESIVE VINYL LABEL TO AFFIX TO ELECTRICAL EQUIPMENT TO WARN OF ARC
FLASH HAZARDS.
2. THE LABEL FORMAT AND TEXT SHALL BE IN ACCORDANCE WITH THE FIGURE.
3. THE LABEL SHALL BE LOCATED ON THE EQUIPMENT TO BE CLEARLY VISIBLE TO QUALIFIED
PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE
EQUIPMENT.
4. THE SIZE OF THE LABEL SHALL BE MINIMUM:
EQUIPMENT TYPE HEIGHT WIDTH
INDOOR 2" 3"
OUTDOOR 3" 4.5"
5. A DOWNLOADABLE WINDOWS METAFILE IS AVAILABLE ON THE WHOLE BUILDING DESIGN GUIDE
WEBSITE (WWW.WDBG.ORG) FOR USE IN A LABEL MAKING MACHINE.
A. THE FILE IS LOCATED ON THE "NAVFAC CADD DETAILS" PAGE. TO NAVIGATE TO THIS
LOCATION, FOLLOW: HOME > DOCUMENTS & REFERENCES > CCB > CADD LIBRARY >
NAVFAC CADD RESOURCES > NAVFAC CADD DETAILS.
B. ALTERNATIVELY, TYPE IN THE FOLLOWING ADDRESS IN INTERNET EXPLORER:
HTTP://WWW.WBDG.ORG/CCB/BROWSE_CAT.PHP?C=232
WIDTH
HEIGHT
(SEE NOTE 1)
SERVICE CAP
CLAMP TYPE
S E
C O
N D
A R
Y
C
O N
D U
C T
O R
N E
U T
R A
L
O
R
T
O P
GRADE
FINISHED
GALVANIZED STEEL CONDUIT-SIZE AS INDICATED
SEE NOTE 3
SEE NOTE 2
CONDUIT LOCATION
OF TRAFFIC
DIRECTION
ROAD SIDE
POSITION
RISER
ALTERNATE
POSITION
RISER
POLE
1.
2.
3.
DIRECT BURIED
CABLE
DIRECT BURIED
CONDUIT
TYPE C
OH-35
JUNE 2002
(SIZE & TYPE AS INDICATED)
CONDUIT RISER
SKETCH DATE STYLE
TYPE A
CONCRETE ENCASED
CONDUIT
TYPE B
18" MIN.
2"
MIN.
NOTES
ON CONDUIT RISER FOR PRIMARY CIRCUITS, ELIMINATE SERVICE CAP
AND PROVIDE GROUNDING TYPE INSULATING BUSHING.
BOND CONDUIT TO POLE GROUND AND SYSTEM NEUTRAL (IF EXISTING).
SEE GROUNDING NOTES ON SKETCH OH-41.
SPACE STRAPS AT MAXIMUM OF 4' INTERVALS.
1'-6" O.C.
3" MINIMUM
FINISHED GRADE
DUCTBANK MARKING TAPE
3000 P.S.I. CONCRETE
P.V.C. CONDUIT SIZE
AS INDICATED
LEVELING BLOCKS
AT BASE SPACERS
M
I N
EQUAL
EQUAL
3" MINIMUM
SEPARATION
(TYP.)
BASE SPACERS
(TYP.)
NOTE: # OF DUCTS SHALL BE AS INDICATED ON PLANS.
3"
SECONDARY
TRANSFORMER BOX, SEE DETAIL A THIS SHEET
GRADE
TERMINATIONS
LOW VOLTAGE CABLE
CURRENT TRANSFORMERS (800/5)
3-POLE FUSE BLOCK
SECONDARY CIRCUIT
WHD
#4/0 BARE
MIN
2'-0"
GRADE.
PAD. MIN 18" BELOW FINISHED
ENCIRCLING ENTIRE CONCRETE
#4/0 BARE COPPER GROUND LOOP
600V INSULATION
CORNER OF PAD.
OF 4, 1 AT EACH
GROUND ROD, TYP
GROUND PAD (TYP OF 2)
#4/0, 600V
INSULATION
PRIMARY CIRCUIT
CONNECTOR
LOAD BREAK
PRIMARY NEUTRAL
BUSHING INSERT
BREAK OIL SWITCH
2 POSITION LOAD
CURRENT-LIMITING
OIL-IMMERSED
PRIMARY COMPARTMENT
ARRESTERS
SURGE
TRANSFORMER
BUSHING WELL
X0
BAYONET OIL-IMMERSED
EXPULSION FUSES
FUSES
CABLE WELL
TRANSFORMER BOX, SEE DETAIL THIS SHEET.
G
G
G
G
GROUND ROD - 3/4" x 10' CONNECT
TO CONDUCTORS BY EXOTHERMIC
WELD (TYP)
PAD MOUNTED COMPARTMENTAL TYPE
TRANSFORMER (SECURE TO TRANSFORMER
BOX PER MANUFACTURER'S
RECOMMENDATION).
SECONDARY NEUTRAL GROUND NO.
4/0 AWG CU MINIMUM
TRANSFORMER
SECTION
EXOTHERMIC WELD (TYP)
EQUIPMENT GROUND
OUTGOING SECONDARY CONDUIT(S)
(NUMBER AS NOTED ON PLANS)
PRIMARY CONDUIT
NUMBER AS NOTED ON
PLANS
EXTEND GRAVEL FILL A
MINIMUM OF ONE FOOT
BEYOND PAD ON ALL SIDES.
WELL COMPACTED GRAVEL
SUBSURFACE SHALL BE 6
INCHES THICK
EXTEND PAD A MINIMUM OF 8
INCHES BEYOND UNIT ON ALL
SIDES
PAD MOUNTED TRANSFORMER DETAIL
NOT TO SCALE
TYPICAL PAD MOUNTED COMPARTMENTAL TRANSFORMER DETAIL
NOT TO SCALE
COMPARTMENT
X10" 10"
6"
9"
18"
2-1/2"
18"
29"
29"
5"
18"
TRANSFORMER BOX DETAIL
(DETAIL BASED ON PARKER BUMPER COMAPNY STANDARD DETAILS)
A
CONCRETE ENCASED DUCTBANK - DETAIL 'A'
NOT TO SCALE
CONNECTOR
LOOP FEED
WATTHOUR DEMAND METER: TO
CONFORM TO BASE
STANDARDS. ITRON V&I CS3
SERIES METER.
EW, SIDES
#4 @ 12"
ANGLE FRAME
WELDED TO
5/8" Ø ANCHOR ROD
A
A
A
(COVER NOT SHOWN)
ANCHORS
A
6"
6"
DUCT ENTRANCE
PLAN
PULLING-IN IRON
7/8" Ø
A
A
6"
& CLAMP
GROUND ROD
TO SUMP
SLOPE 1:40
6"
DUCT ENTRANCE
SECTION A-A
A
COVER
ANCHOR
HANDLE
SECTION B-B
SECTION OF FRAME
1/8"
1 3/4"
3/4"
5" X 5" HINGE
RAISED PATTERN
1/2" FLOOR PL.
L 2 1/2 X 2 1/2 X 3/8
1/2"Ø PLUG WELD
1 3/4" X 1 1/2" X 1/2"
AS SHOWN
CUT HINGE PLATE
1/8"
1 1/4"
SEAL DETAIL
SIDE OF THE DOOR
WELDED TO ONE
2 1/2" X 3/8" SEAL
1/2" PLUG WELD
5"
PLAN OF COVER
B
& COVER
HINGE-WELDED TO FRAME
B
PATTERN
1/2" FLOOR PLATE RAISED
HANDHOLE DIMENSIONS
TYPE
A
3'-0"
1/2" PLUG WELDS
@ 8" O.C. MAX.
12" X 12" X 12"
DEEP SUMP
7/8" Ø
PULLING-
IN IRONS
SEAL, SEE
DETAIL ABOVE
6"
6"
6"
2 4'-0"
(3 PER SIDE)
AND BOTTOM
NOTES:
FOR DETAILS OF CABLE RACKS,
DUCT ENTRANCE AND PULLING-IN
IRONS, SEE PLATE UG-7.
MINIMUM CONCRETE COMPRESSIVE
STRENGTH SHALL BE 3000 PSI.
1.
2.
FLAT PLATE
WATERSTOP AT ALL
CONSTR. JTS. (TYP.)
UG-4
JUNE 2002
TYPES 1 & 2
STANDARD ELECTRICAL HANDHOLE (NONTRAFFIC)
SKETCH DATE STYLE
WALL OF MANHOLE
TYPICAL CABLE RACK
TYPICAL DUCT ENTRANCE
DUCT
INSIDE FACE
OF MANHOLE
45°
3"
DETAIL OF PULLING-IN IRON
7" MIN.
7" MIN.
8 3/8"
7/8"Ø
9"
CAST IN PLACE
3"
1 1/2"
CONCRETE WALL
LOCKWASHER
FILLET WELD
2 1/2"Ø WASHER
6 1/2" X 2 1/2" X 3/16" PLATE
ALTERNATE METHOD
C
L
(MIN)
2 1/2" RAD
1"Ø U-BOLT
1"Ø NUT
1 1/4"Ø SLEEVE
13/16"
3/16"
4"
NOTE
ALL METAL PARTS SHALL
BE HOT DIP GALVANIZED
UG-7
JUNE 2002
(PULLING-IN IRONS, CABLE RACK AND DUCT ENTRANCE)
DETAILS
SKETCH DATE STYLE
A B C D E
LA-7
D3
D3 D3 D3a
Da
V
V
D
D3a
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
C
C
C
C
B
C
C
C
E
D
E
EE
E
E
E
E
E
E
E
E
D
D
D
E
E
D
D
D
D
D
LA-3
MDP LA
LA-3
LA-5 1
LA-1, 2 #10, 1
#10GND - 3/4"C.
P
TC INV
INV
a a a a a a aa a a
V
V
V
V
V
V
The Walker Group Architecture, Inc PO Box 541, New Bern, NC 28563
252.636.8778 (PHONE)
252.636.8992 (FAX)
WALKER
GROUP
i n c o r p o r a t e d the
ARCHITECTURE
DISCLOSURE OF INFORMATION
CONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO
THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR
(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE
(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE
FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE
PROPOSED DATE FOR RELEASE.
(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
TN
PN
FLOOR PLAN
SCALE: 3/16" = 1'-0"
3/16" = 1'-0"
0' 5' 10' 20'
STYLE NO. & TYPE VOLTAGE MOUNTING
NOTES
FIXTURE
SYMBOL
TYPE
OF LAMPS
LED UNIVERSAL
SURFACE; CEILING
PENDANT; 2'-0" BELOW ROOF DECK
LEDNL-11, 4', 4000 LUMENS, 3500K, 29W UNIVERSAL
LED UNIVERSAL
LIGHTING FIXTURE SCHEDULE
NL-67 WALL MOUNTED, 12'-0" A.F.F.
PROVIDE FIXTURE WITH WHITE HOUSING. PROVIDE SINGLE FACE, BACK MOUNTED, RED LETTERING PROVIDE
BATTERY COMPATIBLE WITH REMOTE HEADS.
PROVIDE FIXTURE WITH WHITE HOUSING AND VOLTMETER.
PROVIDE TWO HEADS, VOLTAGE SHALL MATCH EBU, WHITE POLYCARBONATE HOUSING.
DOOR LIGHT
LED UNIVERSAL
WALL, 7'-6" AFF
BUILDING LIGHT
LED UNIVERSAL
WALL; 18' AFF
NL-63
LED UNIVERSAL
WALL MOUNTED, 18" ABOVE DOOR.
A
B
D
E
NL-7, 4', 4504 LUMENS, 3500K, 32W
SEE DETAIL E501
SEE DETAIL E501
LED UNIVERSALNL-54, TYPE E WALL MOUNTED, 9" ABOVE DOOR 3
ROUTE CIRCUIT THROUGH LIGHTING INVERTER, WHEN IN EMERGENCY MODE
ALL LIGHT FIXTURES IN ROOM SHALL BE AT 100% LIGHTING LEVEL.
ROUTE CIRCUIT THROUGH PHOTOCELL AND TIME CLOCK. CONTROL SHALL
BE PHOTOCELL ON/TIME CLOCK OFF.
NOTES THIS SHEET
01/24/2020
RECESSED; CEILINGLEDNL-3, 2X4, 4000 LUMENS, 3500K, 32W UNIVERSAL
C
| 60025498 |
| 60025499 |
| 60025500 |
| Sheets and Views |
| GENERAL NOTES LEGEND AND ABBREVIATIONS |
| 60025501 |
| 60025502 |
| 60025503 |
| 60025504 |