19-0094 Lead Paint Survey Construct EOTG PEB Building RR209 Demolition 021020.pdf
PDF 2 MB Posted
- Attached to
- Construct EOTG PEB
- Solicitation number
- N4008520R4057
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Survey MCL Camp Lejeune – Building RR209
Lead Paint Survey
Construct EOTG PEB, Demolish RR209 MCB Camp Lejeune, NC
Project #19-0094
Report Prepared By:
Christopher B. Walker
The Walker Group Architecture, Inc February 10th, 2020
WGA Project No. – 1918.PEB3
Project Information
The Walker Group Architecture, Inc. was contracted MCB Camp Lejeune to conduct a lead paint survey for repairs to building RR209 prior to demolition in order to construct a new pre-engineered metal building on the same building site. The survey was conducted to determine if building components were coated with lead-based paint.
The building consists of:
a. Building RR209 is an operational training building. The building consists of brick and stud exterior wall construction with stucco finish and interior stud/gypsum board walls. The floors finish is VCT, the building has an asphalt shingle roof system, and a forced air mechanical system.
Scope of Services
A. The survey was performed on January 3rd, 2020, by Christopher B. Walker (NC Accredited Lead Inspector #110239 expires March 31, 2020. Samples were collected from areas defined by the scope of work.
Findings
A. The Walker Group Architecture collected paint chip samples from each surface visibly coated with a different color of paint and delivered them to EMSL Analytical, Inc. (AIHA ELLAP lab code no. 102564) for analysis for lead content by Flame AAS (SW 846 3050B*/7420) in accordance with EPA 3050B/Modified/7000B.
B. OSHA 29 CFR 1926.62 defines any detectable level of lead in paint a concern when renovations/demolitions will impact lead coated surfaces.
C. The detection limit is determined by weight of the sample, which is typically 0.01%.
See attached Lab Results for additional information.
D. Laboratory Results
Suspect Material Sampled Location Condition Concentration % by Weight
Cream Stucco Exterior Intact 0.064%
White Gypsum Board Interior Intact <0.0080%
Cream Gypsum Board Interior Intact <0.0080%
White Wood Trim/Columns Interior Intact 0.29%
White Steel Door Exterior Intact <0.0080%
Based on the sample analysis, the following coatings should be considered Lead Based Paint.
Cream Exterior Stucco
White Interior Wood Trim/ Columns
Recommendations
A. Any demolition/renovation work in which lead coated surfaces are disturbed must be in compliance with all Federal, State, and Local regulations. All work should be conducted by workers trained in "lead safe practices" as outlined by
OSHA.
B. If additional suspect materials are discovered during demolition/renovation, they should be classified presumed to contain lead based paint until sampling by a state of North Carolina licensed Lead Inspector personnel and analysis by an Accredited and state of North Carolina licensed laboratory can be performed.
See attached for Plan Locations, Lead Laboratory Results, and Chain of Custody.
If further information is required, please contact me at 1-252-636-8778
Report Prepared by:
Christopher B. Walker North Carolina Lead Inspector Accreditation# 110239 The Walker Group Architecture, Inc.
PO Box 541 New Bern, NC 28560
ConcentrationAnalyzed Weight Reporting Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 01/07/20 10:30 AM
RR209 - Lead
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
1/3/2020Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
022000104 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
Site: Exterior Cream Stucco
0.064 % wt1/8/2020 .2966 g022000104-0001 0.0080
Client Sample 1/3/2020 pb-01
% wt
Site: Exterior Cream Stucco
0.032 % wt1/8/2020 .2569 g022000104-0002 0.0080
Client Sample 1/3/2020 pb-02
% wt
Site: Interior White Gypsum Board <0.0080 % wt1/8/2020 .3098 g022000104-0003 0.0080
Client Sample 1/3/2020 pb-03
% wt
Site: Interior White Gypsum Board <0.0080 % wt1/8/2020 .2889 g022000104-0004 0.0080
Client Sample 1/3/2020 pb-04
% wt
Site: Cream Gypsum Board <0.0080 % wt1/8/2020 .3164 g022000104-0005 0.0080
Client Sample 1/3/2020 pb-05
% wt
Site: Cream Gypsum Board <0.0080 % wt1/8/2020 .3074 g022000104-0006 0.0080
Client Sample 1/3/2020 pb-06
% wt
Site: Interior White Wood Trim/ Column
0.29 % wt1/8/2020 .3065 g022000104-0007 0.080
Client Sample 1/3/2020 pb-07
% wt
Site: Interior White Wood Trim/ Column <0.0080 % wt1/8/2020 .2686 g022000104-0008 0.0080
Client Sample 1/3/2020 pb-08
% wt
Site: White Exteiror Steel Door <0.0080 % wt1/8/2020 .2983 g022000104-0009 0.0080
Client Sample 1/3/2020 pb-09
% wt
Site: White Exteiror Steel Door <0.0080 % wt1/8/2020 .2856 g022000104-0010 0.0080
Client Sample 1/3/2020 pb-10
% wt
Page 1 of 2Test Report PB w/RD/I-7.32.3 Printed: 1/8/2020 1:47:15 PM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 01/08/2020 13:47:15 http://www.EMSL.com mailto:greensborolab@emsl.com
ConcentrationAnalyzed Weight Reporting Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 01/07/20 10:30 AM
RR209 - Lead
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
1/3/2020Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
022000104 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
Guidelines for Federal USEPA/HUD Lead in Paint Chips =0.5 % Wt or =1.0 mg/cm² is the EPA definition of a lead-based paint.
Above EPA definition of a lead-based paintAbove RL but below EPA definition of a lead-based paint
Below Method Reporting Limit (RL)
These guidance limits are typically used in most scenarios. More stringent local or project specific guidelines may apply.
Please contact the laboratory for statement of uncertainty data for the utility of properly evaluating these results against any regulatory standards or guidelines.
No responsibility or liability is assumed for the manner in which the results are used or interpreted.
Page 2 of 2Test Report PB w/RD/I-7.32.3 Printed: 1/8/2020 1:47:15 PM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 01/08/2020 13:47:15 http://www.EMSL.com mailto:greensborolab@emsl.com
OrderID: 022000104 Page 1 Of
OrderID: 022000104 Page 2 Of
| Building RR209 Lead Survey |
| Building RR209 Lead Plan |
| 022000104_001 |
| 022000104_coc |
File details come from the government source that posted it. Updated .