REPAIR SPALLING CONCRETE -
SEE DETAILS 1/AD501 & 2/AD501
REPAIR SPALLING CONCRETE-
SEE DETAIL 1/AD501
ALLOW 15 EACH THIS TYPE
REPAIR SPALLING CONCRETE -
SEE DETAIL 2/AD501
ALLOW 60 EACH THIS TYPE
REPAIR CONCRETE ANCHOR
ALLOW 15 EACH THIS TYPE
DA1
DA2
SHEET KEYNOTES
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
DEMOLITION PHOTOS
AD901
38 14315 MAY 2020
60023996
15153V
N40085-18-B-0042
05-18-0042
DA1 DEMOLISH EXISTING DOOR AND FRAME COMPLETE. PREPARE OPENING FOR NEW DOOR AND FRAME.
DA2 DEMOLISH EXISTING WINDOW AND FRAME. PREPARE OPENING FOR NEW WINDOW AND FRAME.
DA3 DEMOLISH EXISTING FLOOR FINISH COMPLETE. CLEAN AND PREPARE EXISTING CONCRETE SLAB FOR NEW FINISHES.
DA4 DEMOLISH EXISTING CERAMIC WALL TILE COMPLETE. PREPARE CONCRETE MASONRY FOR NEW FINISHES.
DA5 DEMOLISH EXISTING THINSET CERAMIC TILE FLOOR TILE, CERAMIC WALL BASE AND THRESHOLDS. CLEAN AND PREPARE EXISTING CONCRETE SLAB FOR NEW PORCELAIN TILE
INSTALLATION.
DA6 DEMOLISH EXISTING FLOOR DRAIN, SHOWER PAN, AND WATERPROOFING MEMBRANE COMPLETE. PREPARE FLOOR FOR NEW SHOWER PAN AND FLOOR DRAIN COVER.
DA11 DEMOLISH ALL EXISTING CEILING FINISHES. REMOVE TEXTURED CEILING FINISH DOWN TO CONCRETE SUBSTRATE. PATCH ALL DEFECTIVE AREAS PRIOR TO APPLICATION. SEE FINISH
SCHEDULE.
DA14 DEMOLISH ALL EXISTING TOILET ACCESSORIES INCLUDING, BUT NOT LIMITED TO: TOILET TISSUE DISPENSER, SOAP DISPENSER, TOWEL BARS, SHOWER ROD, SHOWER CURTAIN, GRAB
BAR AND INTEGRAL TRASH/TOWEL RECEPTACLE.
DA16 DEMOLISH EXISTING VANITY CABINET, INCLUDING, BUT NOT LIMITED TO: PORCELAIN SINK, PLUMBING TRIM, PLASTIC LAMINATE COUNTERTOP, AND WALL MOUNTED MIRROR ABOVE.
DA20 DEMOLISH AND REMOVE EXISTING ROOF HATCH, PREPARE OPENING FOR NEW ROOF HATCH.
DA21 DEMOLISH EXISTING CONCRETE GUARDRAILS AT BALCONY COMPLETE. PREPARE FOR NEW METAL GUARDRAIL.
DA31 DEMOLISH EXISTING GYPSUM WALLBOARD AND FRAMING.
DA43 REMOVE WAINSCOT. PATCH AND PREPARE WALL FOR NEW PAINT
SCALE: NOT TO SCALE1
CONCRETE BALCONY GUARD DEMO
SCALE: NOT TO SCALE2
LOUNGE DEMO
SCALE: NOT TO SCALE3
ROOF HATCH DEMO
SCALE: NOT TO SCALE5
SLEEPING ROOM INT SOFFIT DEMO
SCALE: NOT TO SCALE6
VANITY DEMO
SCALE: NOT TO SCALE7
SHOWER DEMO
SCALE: NOT TO SCALE8
EDGE SPALL
SCALE: NOT TO SCALE9
OUTRIGGER SPALL
SCALE: NOT TO SCALE11
REBAR END SPALLSCALE: NOT TO SCALE10
TOP ANCHOR SPALL
SCALE: NOT TO SCALE4
SLEEPING ROOM EXTERIOR DEMO
REVISIONS
SYM. DESCRIPTION DATE APPROVED
W
W W
W W
W W
D D D
D D
D D
D D
D D W
W
W W
W
D D
D
W W
W W
D D
D
W W
W W
D D
D
W
A-201
A-201
A-201
A-201
A-301A-401
A-403
100B
140A
140B135
A
B
100A173B173A
A-301
A-3011 C
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
MECHANICAL
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
M E
C H
A N
IC
A
L
LAUNDRY
T O
IL
E
T R
O O
M
ELECTRICAL
DUTY
C O
R R
ID
O
R
L A
U N
D R
Y R
O O
M
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
MECHANICAL
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
D
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
101B
101C
103B
103C
104B
104C106C
106B
113B
113C
116B
116C
118B
118C
115B
115C
121B
121C
124C
124B
123B
123C
126B
126C
127B
127C
130B
130C
132B
132C
129B
129C
141B
141C
143B
143C
144B
144C
146B
146C
147B
147C
149B
149C
150B
150C
152B
152C
155B
155C
157B
157C
158B
158C
160B
160C
161B
161C
163B
163C
164B
164C
166B
166C
167B
167C
169B
169C
170B
170C
172B
172C
140E
TYP. ALL
BEDROOM
SUITES
A-302
A-302
A-302
A-302
A-302
A-302
A-302
A-302
A-302
A-302
A-302
A-302
A-302
A-302
A-302
A-302
A1
A1A1
A1A1
A1
C
A
A A
A
B B
BB
B B
BB
B B
BB
B B
BB
B B
BB
A A
BB
A A
BB
A A
BB
A A
BB B
F E
C
F E
C F
E C
F E
C
F E
C
A3
A3
A3
305'-8"
FIRE EXTINGUISHER
CABINET - TYP FIVE
(5) PER FLOOR
107B
107C
A-302
A-302
A-302
A-302
106D
101D
CENTRAL STAIR
A
B109B
109C
112C
112B 110B
110C
B
A
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A42 A42
A42A42
A-301
A-401
A
A-301
A-301
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
MECHANICAL
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
MECHANICAL
CENTRAL STAIR
LAUNDRY
T O
IL
E
T R
O O
M
ELECTRICAL
C O
R R
ID
O
R
COMM ROOM
LOUNGE
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
MECHANICAL
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
273A 273B 200B 200A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
240B
240A
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
201B
201C
203B
203C
204B
204C206C
206B
207B
207C
209B
209C
210B
210C
212B
212C
213B
213C
215B
215C
216B
216C
218B
218C
221B
221C
223B
223C
224B
224C
226B
226C
227B
227C
229B
229C
230B
230C
232B
232C
241B
241C
243B
243C
244B
244C
246B
246C
247B
247C
249B
249C
250B
250C252C
252B
255B
255C
257B
257C
258B
258C
260B
260C
261B
261C
263B
263C
264B
264C
266B
266C
267B
267C
269B
269C
270B
270C
272B
272C
A1
A1
A1
A1
A1
A1
A4A4A4A4
A4A4A4A4
C
A A
AA
B B
BB
B B
BB
B B
BB
B B
BB
B B
BB
A A
BB
A A
BB
A A
BB
A A
BB
F E
C F
E C
F E
C
F E
C F
E C
A3
A3
A3
315'-0"
FIRE EXTINGUISHER
CABINET - TYP FIVE
(5) PER FLOOR
206D
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
A43
A43
A43
A43
A43 A43A43
A43
A43
A43
A43
A43
A-301A-401
A
A-301
A-301
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
MECHANICAL
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
MECHANICAL
LAUNDRY
T O
IL
E
T R
O O
M
ELECTRICAL
C O
R R
ID
O
R
STORAGE
LOUNGE
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
MECHANICAL
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
SLEEPING ROOM
BATHROOM
SLEEPING ROOM
300B373B
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
340B
340A
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
300A373A
301B
301C
303B
303C
304B
304C
306B
306C
307B
307C
309B
309C
310B
310C
312B
312C
313B
313C
315B
315C
316B
316C
318B
318C
321B
321C
323B
323C
324B
324C
326B
326C
327B
327C
329B
329C
330B
330C
332B
332C
341B
341C
343B
343C
344B
344C
346B
346C
347B
347C
349B
349C
350B
350C
352B
352C
355B
355C
357B
357C
358B
358C
360B
360C
361B
361C
363B
363C
364B
364C
366B
366C
367B
367C
369B
369C
370B
370C
372B
372C
A1
A1
A1
A1
A1
A1
A4A4A4A4
A4A4A4A4
C
A A
AA
B B
BB
B B
BB
B B
BB
B B
BB
B B
BB
A A
BB
A A
BB
A A
BB
A A
BB
F E
C F
E C
F E
C
F E
C
F E
CA3
A3
A3
FIRE EXTINGUISHER
CABINET - TYP FIVE
(5) PER FLOOR
306D
CENTRAL STAIR
B
A
B
A
B
A
B
A
B
A
B
A
B
A
A
B
B
A
B
A
A43A43 A43
A43 A43 A43
A43
A43
A43
A43
A43
A43
1. COORDINATE WITH DEMOLITION AND CONSTRUCTION PLANS AND
NOTATION ON SHEETS AD101, AD102, AD401, AD402, AND A-101.
2. SEE REFLECTED CEILING PLAN A-102 FOR AREAS TO RECEIVE NEW
CEILING FINISHES, MATERIALS, HEIGHTS, ETC. SEE FINISH SCHEDULE
SHEET A-601 FOR ALL MATERIAL AND COLOR SELECTIONS, AS PER
FINISH DESIGNATIONS FOR EACH IDENTIFIED ROOM ON THE
CONSTRUCTION PLAN. WHERE DOORS ARE INDICATED AS NUMBERED
IN THE CONSTRUCTION PLAN, REFER TO THE DOOR SCHEDULE ON
SHEET A-602 FOR NEW DOOR DESCRIPTIONS, INCLUDING NEW DOOR
FRAME.
3. SEE ENLARGED CONSTRUCTION PLANS AS DENOTED FOR SPECIFIC
CONSTRUCTION SCOPE OF WORK AT INDICATED AREAS.
4. SEE LS101 LIFE SAFETY CODE COMPLIANCE SUMMARY AND LS102
LIFE SAFETY PLAN FOR LOCATIONS AND RATINGS OF FIRE RATED
WALLS.
5. FOR ALL RESTROOMS, SEE ENLARGED PLANS AND ELEVATIONS
SHEET FOR ALL ACCESSORIES AND DELINEATION OF FINISHES. GRAPHIC SCALE
SCALE: 3/32"=1'-0"
816 16
GENERAL NOTES SHEET KEYNOTES
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
PLAN NORTH
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
FLOOR PLANS
A-101
39 14315 MAY 2020
60023997
15153V
N40085-18-B-0042
05-18-0042
SCALE: 3/32" = 1'-0"3
FIRST FLOOR PLAN
SCALE: 3/32" = 1'-0"2
SECOND FLOOR PLAN
SCALE: 3/32" = 1'-0"1
THIRD FLOOR PLAN
A1 DOOR AND FRAME. SEE DOOR SCHEDULE FOR DETAILS.
A3 RETROFIT STAIR TREAD INSTALLATION AT EACH STAIR
NOSING/TREAD, SEE DETAIL 7/A-501.
A4 METAL GUARDRAIL AT BALCONY PROJECTION IN PLACE
OF CONCRETE GUARDRAIL. EXISTING METAL
GUARDRAIL AT WALKWAY TO REMAIN. SEE SHEET A-503
FOR DETAILS.
A42 NEW SIDEWALK. SEE 9/C-502
A43 EXTERIOR PEDESTRIAN TRAFFIC COATING AT ALL
ELEVATED WALKWAYS AND STAIR LANDINGS. SEE
SPECIFICATION 09 67 23.13
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
A-301
A-301
A-301
A-402
TYP. ALL
BEDROOM
SUITES
A28A28A28A28
A28A28A28A28
A-403
A-301
A-301
A-301
A-402
A-301
A-301
A-301
A-402
2 X 2 ACT
CEILING
TYPE X IMPACT
RESISTANT AND
MOISTURE RESISTANT
GWB CEILING
2X2 LIGHT
FIXTURE
SUPPLY
DIFFUSER
RETURN
DIFFUSER
RECESSED
LIGHT FIXTURE
RECESSED SQUARE
LIGHT FIXTURE
CEILING MOUNTED
LIGHT FIXTURE
RECTANGULAR
EXHAUST FAN
ACCESS PANEL
EXIT SIGN
2X4 LIGHT
FIXTURE
1X4 LIGHT
FIXTURE
VANITY LIGHT
FIXTURE
METAL PANEL
CEILING
WALL MOUNT LIGHT
FIXTURE
CIRCULAR EXHAUST
FAN
E
GRAPHIC SCALE
SCALE: 3/32"=1'-0"
816 16
REFLECTED CEILING PLAN LEGEND SHEET KEYNOTES
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
PLAN NORTH
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
REFLECTED CEILING PLANS
A-102
40 14315 MAY 2020
60023998
15153V
N40085-18-B-0042
05-18-0042
A28 REPAIR SPALLING CONCRETE.
SCALE: 3/32" = 1'-0"3
FIRST FLOOR REFLECTED CEILING PLAN
SCALE: 3/32" = 1'-0"2
SECOND FLOOR REFLECTED CEILING PLAN
SCALE: 3/32" = 1'-0"1
THIRD FLOOR REFLECTED CEILING PLAN
A-301
A-301
A-301
A22
A22
A22
A22
A22
A22
A22A22 A22 A22
A21
A19
5" / 12"
A-103
E X
P A
N S
IO
N
J O
IN
T
E X
P A
N S
IO
N
J O
IN
T
43'-6 1/4"14'-7 1/2"57'-4 1/2"14'-7 1/2"
A22
A22 A23
A23
A23A23
A23A23
A23A23
A23A23
A23A23
A23A23
A23A23
A23A23
A23
A23 LIGHTNING PROTECTION. SEE ELECTRICAL
DRAWINGS
OSHA COMPLIANT FALL PROTECTION SYSTEM.
POST LOCATIONS ABOVE PRE-ENGINEERED METAL
TRUSSES BELOW.
A37A37 A37A37 A37
A37
A37A37 A37A37 A37
A37
A22A22A22A22A22
A22
5" / 12"
A-301
A-301
A-301
A-103
D R
A F
T S
T O
P
D R
A F
T S
T O
P
D R
A F
T S
T O
P
D R
A F
T S
T O
P
D R
A F
T S
T O
P
D R
A F
T S
T O
P
CAT WALK - SEE STRUCTURAL CAT WALK - SEE STRUCTURAL
D R
A F
T S
T O
P
400A400B400C400D400E400F400G
A25A25A25A25
A25 A25 A25 A25
A24
38'-0" 46'-8" 40'-2" 43'-10" 46'-8" 38'-0" 31'-9 5/8"
A-502
A-502
5'-8"
ROOF HATCH ABOVE
ROOF ACCESS LADDER
LINE OF PLATFORM
EDGE
CLEAR
3'-4"2HR RATED
ACCESS
HATCH
A-502
CRICKET
3'-0" x 3'-0" ACCESS HATCH
AND ONE PIECE WELDED
AND WATERTIGHT CURB
RIDGE
FALL PROTECTION CABLE
3'-0"
02 4 8134
SCALE: 1/4"=1'-0"
GRAPHIC SCALES
SCALE: 3/32"=1'-0"
816 16
GENERAL NOTES SHEET KEYNOTES
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
PLAN NORTH
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
ROOF PLAN
A-103
41 14315 MAY 2020
60023999
15153V
N40085-18-B-0042
05-18-0042
SCALE: 3/32" = 1'-0"1
ROOF PLAN
A19 RIDGE VENT
A21 ROOF EXPANSION JOINT - FIELD VERIFY EXISTING BUILDING
EXPANSION JOINT LOCATION. ALIGN NEW ROOFING EXPANSION
JOINT WITH EXISTING BUILDING JOINT.
A22 GUTTER
A23 DOWNSPOUT WITH 6X6 GALVANIZED STEEL COVER. SEE CIVIL FOR
UNDERGROUND DRAIN CONNECTION DETAILS.
A24 ROOF ACCESS HATCH. SEE SHEET A-502 FOR DETAILS.
A25 ALUMINUM GABLE VENT LOUVER. SEE 5/A-502 FOR DETAILS.
A37 THROUGH ROOF PLUMBING VENT PENETRATION. SEE DRAWING
8/A-502 FOR DETAIL.
SCALE: 3/32" = 1'-0"2
ATTIC PLAN
SCALE: 1/4" = 1'-0"
A-103
ENLARGED PLAN - CATWALK
SCALE: 1/4" = 1'-0"
A-103
ENLARGED PLAN - ROOF HATCH
1. CONTRACTOR SHALL REPLACE DAMAGED
SHEATHING IF ENCOUNTERED. BID SHALL
INCLUDE 500 SF ROOF SHEATHING
REPLACEMENT MATERIAL AND LABOR.
V
V
V
V
A-203
A-203
A-203
A-203
1'-4" 6'-0" 1'-4" 6'-4" 1'-4" 6'-0" 1'-4"
2"
1'-4" 21'-0" 1'-4"
2" TYP.
23'-8" 2" 23'-8"
1'-4" 6'-0"
1'-4"
6'-4"
1'-4"
6'-0"
1'-4" 2" 1'-4"
6'-4"
1'-4"
6'-0"
1'-4"
6'-0" 1'-4"
23'-8" 2" 23'-8"
2"
1'-3 1/2"
20'-9" 1'-3 1/2"
2"
A-203
"4
" 1
"4
A-203
A-203
MECHANICAL
BUILDING
A501
MECHANICAL
YARD
A502
A-203
47'-6"
LEVEL CHILLER PAD
SLOPE
S L O
P E
S L O
P E
FABRICATED GATE
TO MATCH FENCING
2'-0"8'-0"
A
501B
DOWNSPOUT AND
SPLASHBLOCK (TYP.)
A-203
4" / 12"4" / 12"
2'-0" 23'-4" 2'-0"
27'-4"
A-203
OPEN TO
STRUCTURE
GRAPHIC SCALE
02 4 8134
SCALE: 1/4"=1'-0"
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
PLAN NORTH
CEMS ENGINEERING
R. LEONARD
M. SMITH
M. SMITH
REPAIRS BEQ HP510
MECHANICAL YARD FLOOR, REFLECTED
CEILING, AND ROOF PLAN
A-104
42 14315 MAY 2020
60024000
15153V
N40085-18-B-0042
05-18-0042
SCALE: 1/4" = 1'-0"1
MECHANICAL YARD FLOOR PLAN
SCALE: 1/4" = 1'-0"2
MECHANICAL YARD ROOF PLAN
SCALE: 1/4" = 1'-0"3
MECHANICAL YARD REFLECTED CEILING PLAN
FIRST FLOOR
0"
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
A-301
A-301A-202
5"
12"
A19A20
A22A26A26A22 A26A22
A19
A22
EXISTING BUILDING EXPANSION JOINT.
NEW BACKER ROD AND SEALANT.
A20A26
TYP. ALL
BALCONY
LOCATIONS
A AB BB BB BB BB BA AA AA AA A
A AB BB BB BB BB BA AA AA AA A
A AB BB BB BB BB BA AA AA AA A
A16A16A16
A25 A25 A25 A25 A22A26
A20
A22A26A20A22 A26
5"
12"
FIRST FLOOR
0"
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
A-301
A19 A37A37
5"
12"
5"
12"
A20
A22 A26A22A26
FIRST FLOOR
0"
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
A-301
EXISTING BUILDING EXPANSION JOINT.
NEW BACKER ROD AND SEALANT.
A-301
A26A22A26A22 A26A22A26A22A26 A22 A20
A20 A19 A21 A19
5"
12"
OSHA COMPLIANT FALL PROTECTION SYSTEM.
POST LOCATIONS ABOVE PRE-ENGINEERED
METAL TRUSSES BELOW.
A A B B B B B B B B B B B B B B B B B B
A A B B B B B B B B B B B B B B B B B B
A A B B B B B B B B B B B B B B B B B B
B
A25 A25 A25 A25A22 A26
A24 A20
A22 A26 A20
5"
12"
A-202
FIRST FLOOR
0"
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
A-301A19A20
A22A22A26 A26
A37
5"
12"
5"
12"
GRAPHIC SCALE
SCALE: 3/32"=1'-0"
816 16
SHEET KEYNOTES
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
BUILDING ELEVATIONS
A-201
43 14315 MAY 2020
60024001
15153V
N40085-18-B-0042
05-18-0042
SCALE: 3/32" = 1'-0"
A-101
SOUTH ELEVATION
SCALE: 3/32" = 1'-0"
A-101
WEST ELEVATION
SCALE: 3/32" = 1'-0"
A-101
NORTH ELEVATION
SCALE: 3/32" = 1'-0"
A-101
EAST ELEVATION
A16 INFILL EXISTING OPENING WITH CONCRETE AND BRICK MASONRY.
A19 RIDGE VENT
A20 STANDING SEAM METAL ROOF
A21 ROOF EXPANSION JOINT - FIELD VERIFY EXISTING BUILDING EXPANSION
JOINT LOCATION. ALIGN NEW ROOFING EXPANSION JOINT WITH EXISTING
BUILDING JOINT.
A22 GUTTER
A24 ROOF ACCESS HATCH. SEE SHEET A-502 FOR DETAILS.
A25 ALUMINUM GABLE VENT LOUVER. SEE 5/A-502 FOR DETAILS.
A26 ALUMINUM FASCIA.
A37 THROUGH ROOF PLUMBING VENT PENETRATION. SEE DRAWING 8/A-502
FOR DETAIL.
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
A25
A1 A2
A1 A2
A1 A2
A-302
A23A23
A4
A4
FIRST FLOOR
0"
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
GRAPHIC SCALE
1 2 42
SCALE: 1/2"=1'-0"
SHEET KEYNOTES
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
ENLARGED BUILDING ELEVATIONS
A-202
44 14315 MAY 2020
60024002
15153V
N40085-18-B-0042
05-18-0042
SCALE: 1/2" = 1'-0"
A-201
ENLARGED ELEVATION - BALCONY
A1 DOOR AND FRAME. SEE DOOR SCHEDULE FOR DETAILS.
A2 WINDOW AND FRAME. SEE WINDOW SCHEDULE FOR DETAILS.
A4 METAL GUARDRAIL AT BALCONY PROJECTION IN PLACE OF
CONCRETE GUARDRAIL. EXISTING METAL GUARDRAIL AT WALKWAY
TO REMAIN. SEE SHEET A-503 FOR DETAILS.
A23 DOWNSPOUT WITH 6X6 GALVANIZED STEEL COVER. SEE CIVIL FOR
UNDERGROUND DRAIN CONNECTION DETAILS.
A25 ALUMINUM GABLE VENT LOUVER. SEE 5/A-502 FOR DETAILS.
REVISIONS
SYM. DESCRIPTION DATE APPROVED
SCALE: 1/2" = 1'-0"
A-201
ENLARGED ELEVATION - COMMON AREA
T.O. STRUCTURE
10'-8"
PRECAST
CONCRETE
PIER CAP
FACE BRICK
8' H. ORNAMENTAL
BLACK ALUM.
FENCE
DOWNSPOUT AND SPLASHBLOCK
FIRST FLOOR
0"
T.O. STRUCTURE
10'-8"
STANDING SEAM
METAL ROOF
FACE BRICK
ALUMINUM FASCIA
DOWNSPOUT AND
SPLASHBLOCK
DOWNSPOUT AND
SPLASHBLOCK
FIRST FLOOR
0"
T.O. STRUCTURE
10'-8"
ALUM.
FABRICATED
GATE
DOWNSPOUT AND SPLASHBLOCK
FIRST FLOOR
0"
T.O. STRUCTURE
10'-8"
8' H. ORNAMENTAL
BLACK ALUM.
FENCE
FIRST FLOOR
0"
T.O. STRUCTURE
10'-8"
T.O. FOOTING
-1'-4"
2'-0"
6" CONCRETE SLAB ON GRADE -
SEE STRUCTURAL
CONCRETE FOOTING -
SEE STRUCTURAL
8" CMU W/ HORIZONTAL
REINFORCING @ 16" O.C.
6" CONCRETE SLAB ON GRADE -
SEE STRUCTURAL
BACKER ROD AND SEALANT
BRICK VENEER W/ BRICK
ANCHOR TIES @ 16" O.C.
BOTH DIRECTIONS
THRU WALL FLASHING W/ OPEN
HEAD WEEP HOLES @ 16" O.C.
R-10 RIGID INSULATION
AIR SPACE
ROOF TRUSSES -
SEE STRUCTURAL
2 1/2" METAL STUD INSULATION
SUPPORTS @ 24" O.C.
PREFINISHED
FASCIA
2 LAYERS 2 1/2"
POLYISOCYANURATE
INSULATION BOARDS.
STAGGER JOINTS.
METAL DECK -
SEE
STRUCTURAL
VENTED
ALUMINUM SOFFIT
STANDING SEAM METAL
ROOFING
MORTAR NET
BITUMINOUS DAMPPROOFING PAINT PNT-1
4"
12"
SEE MECHANICAL DRAWINGS
FOR PENETRATION DETAILS
4" PREFINISHED
GUTTER
FIRST FLOOR
0"
T.O. FOOTING
-1'-4"
CONCRETE FOOTING -
SEE STRUCTURAL
GRADE
6" CONCRETE SLAB ON
GRADE
BRICK MASONRY PIER
BEYOND - SEE STRUCTURAL
8' H. ORNAMENTAL BLACK ALUM.
FENCE- MATCH BASE STANDARD
STYLE, COLOR AND FINISH
PRECAST CONCRETE PIER
CAP - SEE STRUCTURAL
EQ EQ
1%
1'-4"
7 5/8" 2"
2 1/4"
3 5/8"
1'-3 1/2"
AIR SPACE
BITUMINOUS DAMPPROOFING
BRICK TIES @ 16" O.C. EA. WAY
8" CMU MASONRY
2" RIGID INSULATION
4" BRICK MASONRY
FIRST FLOOR
0"
T.O. STRUCTURE
10'-8"
SCALE: 1 1/2"=1'-0"
SCALE: 3/4"=1'-0"
12 2
GRAPHIC SCALES
02 4 8134
SCALE: 1/4"=1'-0"
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
CEMS ENGINEERING
R. LEONARD
M. SMITH
M. SMITH
REPAIRS BEQ HP510
MECHANICAL YARD EXTERIOR ELEVATIONS,
SECTIONS, AND DETAILS
A-203
45 14315 MAY 2020
60024003
15153V
N40085-18-B-0042
05-18-0042
SCALE: 1/4" = 1'-0"
A-104
NORTH ELEVATION
SCALE: 1/4" = 1'-0"
A-104
EAST ELEVATION
SCALE: 1/4" = 1'-0"
A-104
SOUTH ELEVATION
SCALE: 1/4" = 1'-0"
A-104
WEST ELEVATION
SCALE: 3/4" = 1'-0"
A-104
SECTION THRU BUILDING
SCALE: 3/4" = 1'-0"
A-104
SECTION THRU MECH. YARD
SCALE: 1 1/2" = 1'-0"
A-104
CORNER PILASTER DETAIL
SCALE: 1/4" = 1'-0"
A-104
WEST ELEVATION - BUILDING
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
T.O. FOOTING
-1'-4"
A-301
A-302
R-40 LOOSE FILL INSULATION
FIRST FLOOR
0"
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
T.O. FOOTING
-1'-4"
A-301
A-302
LOUNGE
MECHANICAL
MECHANICAL
MECHANICAL
LAUNDRY ROOM
LOUNGE
R-40 LOOSE FILL
INSULATION
A-202
FIRST FLOOR
0"
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
T.O. FOOTING
-1'-4"
A-301
A-301
SCALE: 3/16"=1'-0"
48 8
GRAPHIC SCALES
SCALE: 3/32"=1'-0"
816 16
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
BUILDING SECTIONS
A-301
46 14315 MAY 2020
60024004
15153V
N40085-18-B-0042
05-18-0042
SCALE: 3/16" = 1'-0"
A-101
TYP. TRANSVERSE SECTION - SLEEPING ROOM
SCALE: 3/16" = 1'-0"
A-101
TYP. TRANSVERSE SECTION - COMMON AREA
SCALE: 3/32" = 1'-0"
A-101
LONGITUDINAL SECTION
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
T.O. FOOTING
-1'-4"
A-502
R-40 LOOSE FILL INSULATION
EXTERIOR PEDESTRIAN
TRAFFIC COATING. SEE
SPECIFICATION 09 67 23.13
EXTERIOR URETHANE
WALL COATING. SEE
SPECIFICATION 09 67 23.13
EXTERIOR PEDESTRIAN
TRAFFIC COATING. SEE
SPECIFICATION 09 67 23.13
EXTERIOR URETHANE
WALL COATING. SEE
SPECIFICATION 09 67 23.13
FIRST FLOOR
0"
T.O. STRUCTURE
28'-0"
SECOND FLOOR
9'-4"
THIRD FLOOR
18'-8"
T.O. FOOTING
-1'-4"
A-502
A-302
R-40 LOOSE FILL INSULATION
METAL GUARDRAIL AT BALCONY
IN PLACE OF CONCRETE
GUARDRAIL.
EXISTING METAL GUARDRAIL AT
WALKWAY TO REMAIN.
SEE SHEET A-503 FOR DETAILS
METAL RAIL TO REPLACE
CONCRETE GUARDRAIL, SEE
SHEET A-503 FOR DETAILS
FIRST FLOOR
0"
T.O. STRUCTURE
28'-0"
THIRD FLOOR
18'-8"
T.O. FOOTING
-1'-4"
TERMINATE DOWNSPOUT 6"
INSIDE STEEL DOWNSPOUT
GALVANIZED STEEL BASE PLATE W/
LEVELING NUTS 3/4" DIAMETER ANCHOR
BOLTS AND NON-SHRINK GROUT
GROUT BELOW OUTLET
SECURE STEEL DOWNSPOUT
TO EXISTING PRECAST
FASCIA PANEL W/12 GAUGE X
2" WIDE GALVANIZED STEEL
STRAP W/SLOTTED HOLES
AND (2) 1/2" DIAMETER X 2 1/2"
BOLTS SET IN EPOXY
6" WIDE X 6" DEEP GUTTER
WITH 4" DOWNSPOUT LEADER
PRE-FINISHED 0.032"
ALUMINUM FASCIA COVER
WITH DRIP EDGE.
COMPLETELY COVER ALL
WOOD OTHERWISE EXPOSED
TO VIEW WITH ALUMINUM.
FULL PERFORATED VINYL
SOFFIT IN "J" TRIM
6" X 6" X 1/4" GALVANIZED
STEEL TUBE
EXISTING CONCRETE
BALCONY PLANK
EXISTING PRE-CAST
CONCRETE PLANK
4"W X 12"H CLEANOUT
ACCESS HOLE WITH 1/8"
COVER PLATE
PROVIDE HOLE AT PIPE OUTLET
LOCATION
4" GALVANIZED STEEL PIPE OUTLET
LOCATION
DRAIN PIPE - SEE CIVIL DRAWINGS FOR
ADDITIONAL INFORMATION
SECURE TO EXISTING
CONCRETE BALCONY AT
SECOND AND THIRD FLOOR
W/12 GAUGE X 2" WIDE
GALVANIZED STEEL STRAP
W/SLOTTED HOLES AND (2)
1/2" DIAMETER X 2 1/2" BOLTS
SET IN EPOXY
NEW CONCRETE SIDEWALK
CONCRETE FOOTING
(3) #4 BARS E.W.
2'-0"
CONCRETE FOOTING
12" X 14" X 3/8" BASE
PLATE WITH 3/4"
DIAMETER ANCHOR
BOLTS
6" X 6" GALVANIZED
STEEL TUBE
4" GALVANIZED
STEEL PIPE OUTLET
5" 4" 6" 4" 5"
2'-0"
SCALE: 1 1/2"=1'-0"
GRAPHIC SCALES
1 2 42
SCALE: 1/2"=1'-0"
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
WALL SECTIONS
A-302
47 14315 MAY 2020
60024005
15153V
N40085-18-B-0042
05-18-0042
SCALE: 1/2" = 1'-0"1
WALL SECTION - WALKWAY
SCALE: 1/2" = 1'-0"2
WALL SECTION - BALCONY
SCALE: 1 1/2" = 1'-0"3
DOWNSPOUT SECTION
SCALE: 1 1/2" = 1'-0"4
DOWN SPOUT BASE
W
D D
D
W
W W
W
D D
D
W
W W
W W
W W
W W
D D D
D D
D D
D D
D D W
W
W W
W
D D
D
W
A1 A1
A-301
5'-4"
A-301
A-405
200B
A1
MECHANICAL
233C E
N T
R A
L S
T A
IR
LAUNDRY
TOILET ROOM
ELECTRICAL
COMM ROOM
CORRIDOR
LOUNGE
240B
B
273B
A
240A
C
A1
A1
A1
A1
A1
A1
A1
A1
A11 1'-6"
A30
FEC
A14
A13
A1
A-301
A-301
5'-4"
B
340B
373B 300B
340A
A
C
1'-6"
A1
A1
A1
A1 A1
A1
A1
A1
A1
A1
A11
A13
MECHANICAL
LOUNGE
LAUNDRY
TOILET ROOM
ELECTRICAL
CORRIDOR
STORAGE
A1
A30
FEC
A-405
Sim
A1
A14
A1
A1
A1
A1
5'-4"
A-301
A-301
A-401
A-401
A-405
6'-5"4'-6"6'-5"
6'-5"4'-6"6'-5"
MECHANICAL
A1
A1
C
B
1'-6"
A11
LAUNDRY
A1
TOILET ROOM
173B
A1
ELECTRICAL
CORRIDOR
DUTY
A1
A11 A
140A
A1
A1
140B
A11
A11
A1
A1
100B
D
C
A1
140E
A-401
A-401
A-401
A2 A16
A30
6'-0"3'-4"6'-0"
A-501
FEC
L A
U N
D R
Y R
O O
M
A32
A33
A13
1'-0" 3'-4" 1'-0"
A14
FIRST FLOOR
0"
SECOND FLOOR
9'-4"
A-401
ACOUSTICAL
CEILING TILE
3 5/8" METAL STUD W/ R-13
UNFACED FIBERGLASS
BATT INSULATION, 5/8"
IMPACT RESISTANT
GYPSUM BOARD ON
EXTERIOR FACE, 5/8"
MOISTURE RESISTANT ON
INTERIOR FACE. COVER ALL
INTERIOR WALL W/ 1/8" FRP
1/8" FRP ON 5/8" GYP.
BOARD ON 2 1/2" ZEE
FURRING @ 16" O.C. W/
2 1/2" RIGID INSULATION
FIRST FLOOR
0"
SECOND FLOOR
9'-4"
ACOUSTICAL
CEILING TILE
3 5/8" METAL STUD WALL
W/ 5/8" IMPACT
RESISTANT GYP BOARD
ON EXTERIOR FACE.
A11A11
FIRST FLOOR
0"
SECOND FLOOR
9'-4"
LINTEL - SEE
STRUCTURAL
SHEET METAL
PLENUM
FIXED ALUMINUM
LOUVER
SEALANT - ENTIRE
PERIMETER, BOTH
SIDES
EXISTING CONCRETE
MASONRY WALL
EXISTING BRICK
A-605 L3
FIRST FLOOR
0"
A-401
3'-8"
LOUVER - COORD.
W/ MECHANICAL
DRYER
FRP PANEL
INSULATED MAGNETIC GASKET
CONTINUOUS AROUND ALL
THREE SIDES AT EACH DRYER
WALL OPENING. SIM. TO
TRICOMP, INC. MODEL SC-750-875
1X FIBER CEMENT BOARD JAMB
AND CASING OVERLAY
3 5/8" METAL
STUDS
FRP PANEL ON ALL
CHASE INTERIOR WALLS
1X FIBER CEMENT BOARD
JAMB AND CASING OVERLAY
INSULATED MAGNETIC
GASKET CONTINUOUS
AROUND ALL THREE SIDES AT
EACH DRYER WALL OPENING.
SIM. TO TRICOMP, INC. MODEL
SC-750-875
SCALE: 1 1/2"=1'-0"
1 2 42
SCALE: 1/2"=1'-0"
GRAPHIC SCALES
02 4 8134
SCALE: 1/4"=1'-0"
SHEET KEYNOTES
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
PLAN NORTH
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
ENLARGED CORE FLOOR PLANS
A-401
48 14315 MAY 2020
60024006
15153V
N40085-18-B-0042
05-18-0042
SCALE: 1/4" = 1'-0"
A-101
ENLARGED SECOND FLOOR CORE PLAN
SCALE: 1/4" = 1'-0"
A-101
ENLARGED THIRD FLOOR CORE PLAN
SCALE: 1/4" = 1'-0"
A-101
ENLARGED FIRST FLOOR CORE PLAN
SCALE: 1/2" = 1'-0"
A-401
DRYER CHASE
SCALE: 1/2" = 1'-0"
A-401
WASHING MACHINE CHASE
A1 DOOR AND FRAME. SEE DOOR SCHEDULE FOR DETAILS.
A2 WINDOW AND FRAME. SEE WINDOW SCHEDULE FOR DETAILS.
A11 WASHERS AND DRYERS NOT IN CONTRACT.
A13 8” CONCRETE MASONRY WALL, INFILL WHERE EXISTING DOOR AND FRAME HAVE BEEN REMOVED. INFILL OF EXISTING MASONRY LINTEL AT 6’-8” A.F.F.
X THE WIDTH OF THE PREVIOUS OPENING. PROVIDE (1) #4 BAR VERTICALLY IN THE CORNER CELLS WITH MORTAR AS THE WALLS ARE BUILT. PROVIDE 18 GAUGE HOT DIPPED GALVANIZED CORRUGATED WALL TIES AT 1’-4” O.C. VERTICALLY AT EACH INTERSECTION TO EXISTING MASONRY.
A14 6” CONCRETE MASONRY WALL A.F.F. TO THE UNDERSIDE OF STRUCTURE WHERE EXISTING WALL WAS REMOVED. PROVIDE OPENINGS FOR
FIXTURES, COORDINATE WITH MECHANICAL AND PLUMBING FOR OPENING LOCATIONS.
A16 INFILL EXISTING OPENING WITH CONCRETE AND BRICK MASONRY.
A30 8” CONCRETE MASONRY WALL A.F.F. TO THE UNDERSIDE OF STRUCTURE WHERE EXISITNG WALL WAS REMOVED. PROVIDE OPENINGS FOR
FIXTURES, COORDINATE WITH MECHANICAL AND PLUMBING FOR OPENING LOCATIONS.
A32 5/8" GYPSUM WALLBOARD ON 3 5/8" METAL STUD WALL.
A33 LOUVERED OPENING. SEE DETAIL 6/A-401.
SCALE: 1/2" = 1'-0"
A-401
DRYER VENT SECTION
SCALE: 1/2" = 1'-0"
A-401
LOUVER ELEVATION
SCALE: 1 1/2" = 1'-0"
A-401
DRYER WALL PLAN DETAIL
SCALE: 1 1/2" = 1'-0"
A-401
DRYER WALL SECTION DETAIL
A-301
A-301
A-401
A-401
A-401
A-402
A-402
A9
A8
A8 A8
A6
A7
A7
A7
A7
A.F.F.7'-6"
A.F.F.6'-10"
A.F.F.6'-10"
A.F.F.7'-6"A.F.F.7'-6"
A.F.F.7'-6"
A36 A36
A36
A-301
A-301
A-402
A7
A7
A7
A7
A9
A8
A6
A7
A .F
.F
A.F.F.7'-8"
A.F.F.7'-6"
A-301
A-301
A7
A7
A7
A7
A9
A8
A6
A7
A7
A .F
.F
A.F.F.7'-8"
A.F.F.7'-6"
3 5/8" 20 GAUGE
METAL FRAMING
@ 16" O.C.
ACOUSTIC
TILE CEILING
1 5/8" 20 GAUGE
METAL FRAMING
@ 12" O.C.
4'-0"
5/8" GWB WITH
CORNER BEAD
3'-0"
3 5/8" 20 GAUGE
METAL FRAMING
@ 16" O.C.
ACOUSTIC
TILE CEILING
2 1/2" 20 GAUGE
METAL FRAMING
@ 12" O.C.
5/8" GWB WITH
CORNER BEAD
3 5/8" 20 GAUGE
METAL FRAMING
@ 16" O.C.
ACOUSTIC
TILE CEILING
2 1/2" 20 GAUGE
METAL FRAMING
@ 12" O.C.
4'-6"
5/8" GWB WITH
CORNER BEAD
PREFINISHED ANGLE TRIM
PREFINISHED METAL CEILING PANEL
ATTACHED TO METAL FRAMING
18 GAUGE HEADERS
3 5/8" 20 GAUGE FRAMING @
16" O.C. - MAXIMUM SPAN 6'-0"
2 X 2 ACT
CEILING
TYPE X IMPACT
RESISTANT &
MOISTURE
RESISTANT GWB
CEILING
2X2 LIGHT
FIXTURE
SUPPLY
DIFFUSER
RETURN
DIFFUSER
RECESSED
LIGHT FIXTURE
RECESSED SQUARE
LIGHT FIXTURE
CEILING MOUNTED
LIGHT FIXTURE
EXHAUST FAN
ACCESS PANEL
EXIT SIGN
2X4 LIGHT
FIXTURE
1X4 LIGHT
FIXTURE
VANITY LIGHT
FIXTURE
METAL PANEL
CEILING
SCALE: 1 1/2"=1'-0"
1/2 1 21
SCALE: 1"=1'-0"
GRAPHIC SCALES
02 4 8134
SCALE: 1/4"=1'-0"
REFLECTED CEILING PLAN LEGEND SHEET KEYNOTES
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
PLAN NORTH
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
ENLARGED CORE REFLECTED CEILING
PLANS
A-402
49 14315 MAY 2020
60024007
15153V
N40085-18-B-0042
05-18-0042
SCALE: 1/4" = 1'-0"
A-102
ENLARGED FIRST FLOOR CORE REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
A-102
ENLARGED SECOND FLOOR CORE REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
A-102
ENLARGED THIRD FLOOR CORE REFLECTED CEILING PLAN
A6 5/8” TYPE X IMPACT RESISTANT GYPSUM BOARD CEILING
AND BULKHEAD (TYPICAL AT EACH LOUNGE AND
LAUNDRY ROOM). SEE CORE AREA DETAILS ON A-402
FOR CEILING HEIGHTS AND STRUCTURAL
REQUIREMENTS. ALL EXPOSED SURFACES SHALL BE
PAINTED.
A7 EXISTING CONCRETE PLANK CEILING TO BE CLEANED
AND PREPARED FOR NEW PAINT. SEE FINISH SCHEDULE.
A8 ACOUSTICAL CEILING TILE AND SUSPENSION SYSTEM.
A9 FLUSH PROFILE METAL PANEL CEILING. SEE DETAIL
7/A-402 FOR ASSEMBLY REQUIREMENTS.
A36 SEE CHASE WALL PENETRATION DETAIL 3/A-501
SCALE: 1" = 1'-0"
A-402
LOUNGE SOFFIT DETAIL
SCALE: 1" = 1'-0"
A-402
LAUNDRY SOFFIT DETAIL
SCALE: 1" = 1'-0"
A-402
LAUNDRY SOFFIT DETAIL
SCALE: 1 1/2" = 1'-0"7
METAL CEILING DETAIL
A-404
A1A1 A2A2
A1 A1
A1A1 A2A2
LINE OF MOISTURE
AND IMPACT
RESISTANT GWB
CEILING ABOVE
A29A29
A29A29
A1
A1
A1
A1
A1
A1
A1
A1
A1A1
12'-0 3/8"
25'-4"
A5
A5
A7
A5
A5
A7
A7A7
A5
A5
A39A39
12'-0 3/8" 12'-0 3/8"
9'-8 3/4"
A-501
TYP.
A-501
TYP.
A.F.F.7'-0"
A.F.F.7'-0"
A5
A5
A5
A5 A5
A5
GRAPHIC SCALE
02 4 8134
SCALE: 1/4"=1'-0"
SHEET KEYNOTES
108 Bentons Lodge Rd., Summerville, SC, 29485
ENGINEERING | ARCHITECTURE
CEMS Project No: Project Manager: R. Alvar
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY
MARINE CORPS BASE
CAMP LEJEUNE, NORTH CAROLINA
NAVAL FACILITIES ENGINEERING COMMAND
SIZE CODE IDENT NO. NAVFAC DRAWING NO.
SCALE: SPEC. SHEET OF
E1 80091
300 N. 3rd St., Suite 110, Wilmington, NC, 28401 843.875.3637 910.363.1640
CONSTR. CONTR. NO.:
ISSUE DATE:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S
ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THE CONTRACT OR ANY PROGRAM RELATED TO THIS
CONTRACT, UNLESS-
1. THE CONTRACTING OFFICE HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS
REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE PROPOSED DATE FOR
RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT
UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO
RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
DISCLOSURE OF INFORMATION
AS NOTED
PLAN NORTH
CEMS ENGINEERING
P. HARRIS/ R. LEONARD
M. SMITH
M. SMITH
REPAIR BEQ HP510
ENLARGED SLEEPING ROOM FLOOR PLAN
AND REFLECTED CEILING PLANS
A-403
50 14315 MAY 2020
60024008
15153V
N40085-18-B-0042
05-18-0042
SCALE: 1/4" = 1'-0"
A-101
ENLARGED SLEEPING ROOM FLOOR PLAN
SCALE: 1/4" = 1'-0"
A-102
ENLARGED SLEEPING ROOM REFLECTED CEILING PLAN
A1 DOOR AND FRAME. SEE DOOR SCHEDULE FOR DETAILS.
A2 WINDOW AND FRAME. SEE WINDOW SCHEDULE FOR DETAILS.
A5 5/8” TYPE X IMPACT AND MOISTURE RESISTANT GYPSUM BOARD CEILING AND BULKHEAD (TYPICAL AT EACH SLEEPING ROOM, INCLUDING BATHROOM/SHOWER AND VANITY/CLOSET AREA). SEE SLEEPING ROOM ELEVATIONS ON A-404 FOR CEILING HEIGHTS AND STRUCTURAL REQUIREMENTS. ALL EXPOSED
SURFACES SHALL BE PAINTED.
A7 EXISTING CONCRETE PLANK CEILING TO BE CLEANED AND PREPARED FOR NEW PAINT. SEE FINISH
SCHEDULE.
A29 FLOOR DRAIN IN SAME LOCATION AS EXISTING.
A39 SHOWER WALLS SHALL BE BRACED BY CEILING FRAMING MEMBERS. LAYOUT FRAMING MEMBERS TO CONSTRUCT MINIMUM TWO (2) 3 5/8" 20 GA. CEILING JOISTS PERPENDICULAR TO SHOWER WALLS ABOVE
THE SHOWER AND THE WATER CLOSET TO CREATE A RIGID CONNECTION FULL WIDTH OF ROOM.
| N4008518B0042Dwg1 |
| N40085-18-B-0042 DRAWINGS 1 |
| ARCHITECTURAL PLANS |
| 60023996, AD901, DEMOLITION PHOTOS |
| 60023997, A-101, FLOOR PLANS |
| 60023998, A-102, REFLECTED CEILING PLANS |
| 60023999, A-103, ROOF PLAN |
| 60024000, A-104, MECHANICAL YARD FLOOR, REFLECTED CEILING, AND ROOF PLAN |
| 60024001, A-201, BUILDING ELEVATIONS |
| 60024002, A-202, ENLARGED BUILDING ELEVATIONS |
| 60024003, A-203, MECHANICAL YARD EXTERIOR ELEVATIONS, SECTIONS, AND DETAILS |
| 60024004, A-301, BUILDING SECTIONS |
| 60024005, A-302, WALL SECTIONS |
| 60024006, A-401, ENLARGED CORE FLOOR PLANS |
| 60024007, A-402, ENLARGED CORE REFLECTED CEILING PLANS |
| 60024008, A-403, ENLARGED SLEEPING ROOM FLOOR PLAN AND REFLECTED CEILING PLANS |
| 60024009, A-404, ENLARGED SLEEPING ROOM ELEVATIONS AND DETAILS |
| 60024010, A-405, ENLARGED TOILET ROOM PLANS AND ELEVATIONS |
| 60024011, A-501, DETAILS |
| 60024012, A-502, ROOF DETAILS |
| 60024013, A-503, RAILING DETAILS |
| 60024014, A-504, CASEWORK DETAILS |
| 60024015, A-601, FINISH SCHEDULE AND DETAILS |