0090_A_Daily_COVID_19_Prevention_and_Control_Services_Rev_K.docx
DOCX document 500 KB Posted
- Attached to
- USNS HENRY J. KAISER FY21 MTA
- Solicitation number
- N3220520R4066
About this file
This document outlines requirements for cleaning services to prevent the spread of COVID-19 during a ship maintenance period. The contractor shall provide daily cleaning of areas accessed by workers in accordance with Centers for Disease Control guidelines. High-touch surfaces must be cleaned every two hours using Naval Sea Systems Command approved disinfecting agents. Personnel shall be trained on proper cleaning methods and personal protective equipment. The contractor must track cleaning progress and provide daily reports to the Military Sealift Command. Physical distancing and designated eating and smoking areas shall be enforced.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USNS Kaiser
(TAO 187)
| 0000 |
| N32205-20-R-4066 |
| ITEM NO. 0090 |
| CATEGORY "A" |
| 06/03/2020 |
| Daily COVID 19 Prevention and Control Services Rev K |
| TBD |
1. ABSTRACT
1.1. This item describes the requirements for the contractor to provide cleaning services in an attempt to control and prevent the spread of COVID-19 for duration of the maintenance and repair period.
2. REFERENCES/ENCLOSURES
2.1. References:
2.1.1. MSC Drawing No. 101-5904166 , Booklet of General Arrangement and Profile Drawings
2.1.2. MSC COVID-19 Screening Questionnaire V2020 04.29
2.1.3. OSHA guidance on the control and prevention of COVID-19. https://www.osha.gov/SLTC/covid-19/controlprevention.html
2.1.4. MSC QMS instruction N2.35.6100.1-Q Novel Coronavirus Disease Response Plan Revision 4 dated May 8, 2020 with enclosures 1-10
2.2. Enclosures:
2.2.1. NAVSEA SUBJ: Updated Products List for Use in Large Area Disinfection of Coronavirus
3. ITEM LOCATION/DESCRIPTION
3.1. Location/Quantity
3.1.1. Areas of the vessel undergoing work or transited by the contractor: Use reference 2.1.1 as guidance for planning and estimating locations where work identified in this work package will require contractor access or transit.
3.1.2. When the crew is living aboard, those areas will remain the responsibility of the ship’s force, no production or cleaning work will be accomplished in those habitability or messing spaces.
4. GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES: None
5. NOTES
5.1. The contractor and all subcontractors, regardless of tier must consult the General Technical Requirements (GTR) to determine applicability to this work item. In performance of this work item, the contractor and all subcontractors regardless of tier must comply with all applicable GTR requirements.
5.2. The definitions of many terms used in this work item are found in Work Item 001.
5.3. Fogging or large scale spraying operations are not authorized onboard any MSC ship.
6. QUALITY ASSURANCE REQUIREMENTS
6.1. The contractor shall track the progress of the cleaning and provide daily reports, including reference to the space and description of the surface(s) of areas cleaned and the times completed. Reports shall be provided to the MSCREP daily via a condition report and posted at the entrance or the space.
6.2. Contractor shall provide supervision of the cleaning crew using CDC guidelines and assessment tools to help ensure the efficacy of the cleaning methods.
6.3. All cleaning agents used in the performance of this item must conform to the requirements of Naval Sea Systems Command (NAVSEA) found in enclosure 2.2.1. In the event that approved cleaner is not available the contractor shall submit a request for a equivalency waiver to the MSCREP for evaluation with NAVSEA. The product information submitted shall include the Material Safety Data Sheets and Technical Data Sheets
6.4. Cleaning to be accomplished by personnel with training in the control and prevention of COVID-19.
6.4.1. Cleaners shall be trained on
6.4.1.1. Proper disinfection methods for working in an industrial environment
6.4.1.2. Proper use of the cleaner being used
6.4.1.3. Proper use of Personal Protective Equipment (PPE)
6.4.2. Evidence of training in section 6.4.1 shall be provided to the MSCREP via a condition report upon commencement of cleaning activities.
7. STATEMENT OF WORK
7.1. Using the guidance provided in reference 2.1.3, OSHA Guidance on the Control and Prevention of COVID-19 and the requirements outlined in this specification, the contractor shall provide mitigation measures and cleaning services in support of the control and prevention of the spread of COVID-19 onboard the vessel during the period of performance.
7.2. Minimize Travel Through the Ship:
7.2.1. Contractor shall coordinate with the MSCREP to develop a transit path which will be followed by ship’s force, contractor personnel, and subcontractors.
7.2.1.1. Transit path shall include the following characteristics to the maximum extent practical: one way traffic lanes, maximization of external pathways, and reduction of the total travel length to the work space.
7.2.1.2. Signs shall be posted showing directions. Signs shall be of adequate quantity so at least one sigh can be seen from anywhere along the transit route.
7.2.1.3. Laminated signs shall be posted on bulkheads and decks throughout the ship reminding of CDC and MSC guidelines for reducing the spread of the virus. These include social distancing practices, PPE requirements (face mask), and regular washing or sanitizing of hands.
7.2.2. Contractor shall coordinate with the MSCREP and ship’s force to secure spaces where there is no on-going work. If there is a door to enter the space it shall be locked and a placard shall be placed on the door stating the space is off limits, with the date the space is secured. If the space is open without a doorway the contractor shall cordon off the area using physical barriers, such as chain, tape, etc., and an appropriate notice. The space may be briefly opened only during fire and flooding watch standing activities (detex rounds), if it is opened and accessed for other reasons it must be re-cleaned.
7.3. Personal Protective Equipment and Personnel Screening for entry to the vessel:
7.3.1. All personnel (contractor employees, subcontractors, and any other persons accessing the vessel) shall don PPE in accordance with the MSC QMS Instruction reference 2.1.4.
7.3.2. For maintenance at a Contractor’s facility, contractor shall develop and implement a medical screening process for all visitors, vendors, contractors and shipyard employees passing into the facility. Medical screening process shall incorporate daily temperature readings, answering the MSC provided questionnaire (reference 2.1.2), and a method of proving the individual has successfully completed the process each day that is visible at all times (daily sticker).
7.4. Handwashing Stations:
7.4.1. Handwashing stations are to be provided at the quarterdeck and at each deck level. If ships potable water is secured portable handwash stations are to be provided.
7.4.2. Where handwashing stations are not feasible due to location hand sanitizer consisting of at least 60% ethanol or 70% isopropanol shall be provided.
7.5. Cleaning of the Ship:
7.5.1. Cleaning to be accomplished by personnel trained on the disinfection procedures and PPE usages listed below.
7.5.1.1. Cleaning personal shall be trained and familiar with the following methods and equipment:
7.5.1.1.1. Proper Cleaning and disinfection methods for an industrial shipboard environment.
7.5.1.1.2. Proper use of cleaners as per manufacturer guidelines.
7.5.1.1.3. Proper training in the use of Personal Protective Equipment (PPE) to include face masks, respirators, gloves, and barrier clothing,
7.5.1.2. Evidence of training shall be provided to the MSCREP via a condition report upon commencement of cleaning activities.
7.5.2. All the spaces where production work is ongoing or the space transited by the contractor shall be cleaned.
7.5.3. Clean and disinfect high traffic and frequently touched areas and objects every two hours including but not limited to tables, doorknobs, doorframes, light switches, chairs, tables, appliances, countertops, handles, desks, phones, keyboards, toilets, faucets, sinks, hand rails in stairways and hallways, lounges, vestibules into house, machine shops and gangways, portable toilet facilities, exterior handrails (including exterior/interior to the vessel and engine room), stair towers, vertical ladder rungs, doors, door knobs, quarterdeck and gangways using NAVSEA approved cleaning agents.
7.5.4. All decks, passageways and work areas shall be swept clean and cleared of debris then mopped on a daily basis using approved cleaner.
7.5.5. All bulkheads up to 6 feet shall be cleaned and sanitized weekly using approved cleaner.
7.5.6. The contractor shall coordinate with the engineering crew prior to utilizing any cleaning solutions on electronics or machinery spaces.
7.5.7. Special care must be taken around energized electrical equipment to damage electrical equipment and prevent electric shock. No electrical appliances shall be sprayed, all electrical and electronic devices shall be wiped down with cleaner only.
7.5.8. Clean all surfaces in accordance with the cleaning product manufacturer’s directions. Rags used for wiping surfaces shall be changed for every new space or when they have been soiled. Rags shall not be re-used unless they have been washed and sanitized.
7.5.9. Once a space has been cleaned and no further contractor access is anticipated, the space shall be secured. A label shall be provided and posted on access to the space indicating clean status and date/time of the final cleaning. If a contract worker re-enters the space for any reason, the contractor shall re-clean the space.
7.5.10. Contractor shall ensure common access shipboard and portable toilet facilities are stocked with soap, FDA approved hand sanitizer, disposable disinfecting wipes and paper products. Common access shipboard and portable toilet facilities shall be cleaned and restocked at a minimum of twice daily.
7.5.11. The contractor shall provide hand sanitizer and disposable disinfecting wipes approved by the FDA and/or EPA at all manned watch stations, to include but not limited to the bridge, engine room control room, and the gangway. These supplies shall be checked twice daily and re-stocked as required. This is in addition to the hand sanitation stations identified in work item 010 & 011.
7.5.12. The contractor shall develop a spreadsheet / check sheet indicating areas cleaned using reference 2.1.1. The contractor shall maintain a daily marked-up of reference 2.1.1.
7.5.13. The contractor shall track the progress of the cleaning and provide the MSCREP daily condition reports, including a reference to the spaces, description of the surface(s) of areas cleaned, type of cleaner used in each space and times at which the last cleanings were completed. In addition to providing to the MSCREP daily, the reports shall be posted at the entrance at each applicable space.
7.5.14. Contractor shall provide supervision of the cleaning crew using CDC guidelines and assessment tools to ensure the efficacy of the cleaning methods and procedures.
7.6. Designated Eating Areas:
7.6.1. Eating onboard the vessel is prohibited. A designated space for crew and workers to eat is to be provided. Space is to be thoroughly cleaned prior to meal breaks. Physical distancing is to be enforced.
7.7. Designated Smoking Areas:
7.7.1. Designated smoking areas are to be provided by the shipyard. Physical distancing is to be enforced.
8. GENERAL REQUIREMENTS
8.1. None additional.
Enclosure 2.2.1
0090 - 1 NAVSEA UPDATED PRODUCTS LIST FOR USE IN LARGE AREA DISINFECTION OF CORON.pdf
DEPARTMENT OF THE NAVY
NAVAL SEA SYSTEMS COMMAND
1333 ISAAC HULL AVE SE
WASHINGTON NAVY YARD DC 20376-0001
IN REPLY REFER TO
10480 Ser 05Z/216 14 Apr 20
From: Commander, Naval Sea Systems Command (SEA 05Z)
Subj: UPDATED PRODUCTS LIST FOR USE IN LARGE AREA DISINFECTION
OF CORONAVIRUS
Ref: (a) COMNAVSEASYSCOM WASHINGTON DC 110050Z Apr 20
(FLTADVISORY 03/20)
Encl: (1) Updated NAVSEA Recommended Products List
1. Background. Reference (a) provided guidance to conduct large area cleaning and disinfection for Surface Ships and Aircraft Carriers. Additionally, reference (a) contained a list of recommended disinfection products for use in large area decontamination. To ensure sufficient supplies of effective cleaning and disinfection products are available to conduct large area decontamination, NAVSEA continues to evaluate potential products to be added to those recommended in reference (a).
2. NAVSEA Action
a. NAVSEA has reviewed and approves the use of the recommended disinfection products to conduct large area cleaning and disinfection as described in reference (a).
b. NAVSEA will continue to evaluate other disinfection products and update the approved list as necessary.
3. NAVSEA point of contact for this letter is D. E. Arnold, SEA 05Z, DSN 326-1721, commercial (202) 781-1721, or email:
douglas.e.arnold@navy.mil.
D. E. ARNOLD
By direction
Distribution: (electronic distribution only) https://community.max.gov/pages/viewpage.action?spaceKey=DoD&tit le=Navy+Medicine+COVID-19+Response https://community.max.gov/pages/viewpage.action?spaceKey=DoD&title=Navy+Medicine+COVID-19+Response https://community.max.gov/pages/viewpage.action?spaceKey=DoD&title=Navy+Medicine+COVID-19+Response
Enclosure (1)
14 Apr 2020
Updated NAVSEA Recommended Large Area Cleaning Products
NAVSEA recommended products are quaternary ammonium based disinfectant cleaners (NSN or purchase locally). These compounds are well known and are the active ingredients in household non‐ bleach wipes such as Clorox wipes. They are extremely effective at neutralizing enveloped viruses (SAR‐COV‐2 / COVID‐19 is an enveloped virus). The following preferred products are commonly used effective disinfecting agents which have no detrimental impacts to fabrics when used in recommended diluted concentrations per the manufacturer directions. Recommended cleaners include:
a. NSN 6840‐00‐201‐2505, MIKRO‐QUAT INC. ECOLAB, EPA‐N list item 1677‐21, quaternary ammonium ethanol blend, 1 gallon, cage code 85884. This product should be diluted at a ratio of 1 ounce per 1 gallon per manufacturer specifications.
b. NSN 6840‐01‐604‐6411, CAVICIDE, METREX RESEARCH, quaternary ammonium‐isopropanol blend. EPA‐N list item 46781‐6.
This product should be used as received; no dilution is recommended per manufacturer’s specification.
c. LYSOL BRAND I.C. quaternary ammonium deodorizing disinfectant cleaner, EPA‐N list item 675‐54; 24 ounce bottles, no NSN. This product should be diluted at a ratio of 1:256 (0.5 ounce concentrated solution diluted with 1 gallon of water) per manufacturer’s specification.
d. DECON 7 part 1. EPA‐N list 89833‐3; no NSN (note: part 1 consists of a blend of quaternary ammonium compounds and surfactants). This product should be diluted at a ratio of 1:1
(1 gallon of concentrated solution diluted with 1 gallon of water) per manufacturer’s specification.
e. MAQUAT 2420‐10 EPA‐N list 10324‐194. No NSN. This product should be diluted at a ratio of 1.5 ounce per 1 gallon of water per manufacturer’s specification.
f. NSN 7930‐01‐589‐0598, multi‐surface sanitizer (VIREX II
256), DIVERSEY, EPA‐N list item 70627‐24, quaternary ammonium ethanol blend, 6‐32oz, cage code 325G4. This product should be diluted at a ratio of 1:256 (1 ounce concentrated solution
Enclosure (1) diluted with 2 gallons of water) per manufacturer’s specification.
g. Oasis 146 MULTI‐QUAT sanitizer; NIIN 01‐589‐3786; this product should be diluted at a ratio of 2 ounces per gallon of water (this is lower than the manufacturer's recommendation).
* h. NSN 6840-01-398-0974 ECOLAB disinfectant cleaner 2.0.
This product should be diluted 2.0 ounces of the concentrated solution with 1 gallon of water (as recommended by the manufacturer).
Note (1): Ensure chemical dilution instructions are strictly followed to prevent safety hazards from strong solutions or ineffective disinfection from weak solutions.
Note (2): Other products containing quaternary ammonium may be used if approved via a SHML Feedback Report (SFR). Surface ships are to download the SFR spreadsheet template and utilize, as required, to post SFR smil feedback details in the electronic advisory record repository and tracking system (EARRTS) advisory tracking record (ATR), as applicable.
* Designates added disinfecting agent since release of Reference
(a).
Ser 05Z_216 Updated Products List for use in Large Area Disinfection of Coronavirus 14 Apr 20
D. E. ARNOLD
By direction
Distribution: (electronic distribution only)
Encl (1) LARGE AREA DISINFECTING PRODUCTS UPDATED 14 APR 2020
2020-04-14T16:24:33-0400
ARNOLD.DOUGLAS.EVAN.1042886501
image1.emf
File details come from the government source that posted it. Updated .