18R0005_0002.docx
DOCX document 35 KB Posted
- Attached to
- Hardware Components for the ASM Hand Grenades Federal contract opportunity
- Solicitation number
- N00174-18-R-0005
About this file
Amendment 0002 and additional Questions from Offerors
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N00174-18-R-0005_ASM_Grenade_Attachments.pdf | ||
| N00174-18-R-0005_ASM_Grenade_3-23.pdf | ||
| 18R0005_Amd_1.docx | DOCX document | |
| Drawing_430-174-0013_Rev_E.pdf | ||
| Vendor_Questions.docx | DOCX document | |
| 18R0005_Amendment_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N0017418R0005
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
The following items are applicable to this modification:
SUMMARY OF CHANGES
SUMMARY OF CHANGES
1. SECTION A - SOLICITATION/CONTRACT FORM
The required response date/time has changed to 10-May-2018 01:00 PM Eastern Standard Time.
2. The following additional Questions and Answers are hereby provided:
1. Drawing Numbers 430-174-0006 & 430-174-0007 both call out a helical groove (similar to a thread) of 40 pitch with a depth of .005” ± .002” throughout the diameter. What would be the preferred inspection method? Optical comparator? Dedicated gage similar to a thread gage?
Ref: Drawing Numbers 430-174-0006 & 430-174-0007
ANSWER: Up to the offeror to make recommendation of how they will inspect the part.
1. The Contractor shall provide inspection/test results for each hardware component which shall include dimensional data for units measured during production, but 100% dimensional verification shall be performed on a minimum of every 10th parts. 100% inspection on all parts is not required, but will the critical dimensions that need to be provided on each part be specified by the Government prior to the contract award?
Ref: Section 3.2.2.1 on page 21 & Section 4.0 on page 22
ANSWER: All dimensions called out on the drawings shall be verified as part of the inspection of every 10th part.
1. Does the pressure testing requirement include the small Ø.126 hole on the upper neck or only for the body and bottom cap?
Ref: Pressure Testing Requirement
ANSWER: The pressure testing requirement does not include the small hole on the upper neck and is only for the body and bottom cap.
1. Please confirm if the pressure testing requirement is a dry air pressure test, and not a water, or a submersion bubble test.
Ref: Pressure Testing Requirement
ANSWER: Requirement is for dry air pressure testing on 100% of the units.
3. For further information regarding this amendment please contact Larry Connell at 301-744-6641 or lawrence.connell@navy.mil.
(End of Summary of Changes) image1.wmf
File details come from the government source that posted it.