MINI SPLIT_drawings_2024-12-05.pdf
PDF 2 MB Posted
- Attached to
- Ductless Mini-Split Heating & Cooling System for DCR Room at Joint Base Cape Cod Bldg #2410
- Solicitation number
- 6913G625Q300009
About this file
This file contains architectural and mechanical drawings dated December 5, 2024, for the installation of a mini-split HVAC system in Room #4 of Building #2410 at Joint Base Cape Cod in Sandwich, MA. The drawings include detailed floor plans, general notes, demolition requirements, and specifications for a new ductless mini-split heating/cooling system with wall-mounted blower unit for Zone 4 and a free-standing condenser unit.
The drawings consist of six sheets covering architectural, mechanical, and electrical details including cover sheet, general notes and abbreviations, demolition notes, HVAC floor plan, electrical floor plan, and power panel schedules. The mechanical plans show the installation location in a 112 SF shower room with 14-foot ceiling height and uninsulated exterior CMU walls. The drawings specify requirements for control systems, thermostats, ductwork modifications, and electrical connections, including panel load specifications showing connected loads and demand factors. The building is governed by 2018 IBC code requirements and is classified as Business Group B occupancy.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USDOT/VOLPE CENTER
DEPARTMENT OF TRANSPORTATION
Room #4 MINI-SPLIT INSTALLATION
BUILDING #2410
JOINT BASE CAPE COD
SOUTH INNER ROAD
SANDWICH, MA 02542
December 5, 2024
OWNER/LESSOR:
Commonwealth of Massachusetts
Executive Office of Public Safety & Security
Military Division
2 Randolph Road
Hanscom AFB Bedford, MA 01731
PROJECT LOCATION
REGIONAL MAP SITE MAP
I SHEET I DRAWING NUMBER I SHEET NAME
GENERAL
SHEET 01 MINI-SPLIT G-000 COVER SHEET
SHEET02 MINI-SPLIT G-001 ARCH GENERAL NOTES, SYMBOLS, & ABBREVIATIONS
SHEET 03 MINI-SPLIT G-002 DEMOLITION, ELECTRICAL, MECHANICAL GENERAL NOTES, SYMBOLS, & ABBREVIATIONS
MECHANICAL
SHEET 04 MINI-SPLIT M-101 HVAC FLOOR PLAN
ELECTRICAL
SHEET 05 MINI-SPLIT E-101 ELECTRICAL FLOOR PLAN
SHEET 06 MINI-SPLIT E-201 POWER PANEL SCHEDULES
SHEET 01 MINI-SPLIT G-000
ARCHITECTURAL ABBREVIATIONS LIST:
A A
ACT ACOUSTIC CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AL ALUMINUM
ALT ALTERNATE
AP ACCESS PANEL
ARCH ARCHITECTURAL
AUTO AUTOMATIC
B B
BO BOARD
BIT BITUMINOUS
BLDG BUILDING
BL BLOCKING
BM BEAM
BR BRICK
BSMT BASEMENT
BTW BETWEEN
C C
CAB CABINET
CPT CARPET
GER CERAMIC
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
CG CORNER GUARD
CJ CONTROL JOINT
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMB COMBUSTIBLE
CON CONDITION
CONG CONCRETE
COND CONDUIT
CONF CONFERENCE
CONN CONNECTION
CONT CONTINUOUS
CONST CONSTRUCTION
GOOD COORDINATE
CORR CORRIDOR
cw COLD WATER
D D
DBL DOUBLE
DEG DEGREE
DEMO DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DIR DIRECTOR
DN DOWN
DR DOOR
DS DOWNSPOUT
DTFPEPE DESIGN TEAM FIRE PROTECTION ENGINEER
PROFESSIONAL ENGINEER
DW DISH WASHER
DWG DRAWING
E E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC
ELEV ELEVATOR
EMG EMERGENCY
EMP EMERGENCY POWER
ENCL ENCLOSED
EOAE EQUIVALENT OR APPROVED EQUAL
ES EACH SIDE
ETR EXISTING TO REMAIN
EQ EQUAL
EQUIP EQUIPMENT
EXH EXHAUST
EX EXISTING
EXT EXTERIOR
! STORAGE MECHANICAL RM
F F M
FA FIRE ALARM MFR
FON FOUNDATION MIN
FE FIRE EXTINGUISHER MIR
FEC FIRE EXTINGUISHER CABINET MISC
FF FINISH FLOOR MLDG
FHC FIRE HOSE CABINET MLWK
FIN FINISHED MO
FLASH FLASHING MOD
FLEX FLEXIBLE MT
FLR FLOOR MTD
FLOUR FLUORESCENT MTL
FP FIRE PROOFING MUL
FRZ FREEZER
FT FEET,FOOT N
FURR FURRING N
NIC
G G NO
GALV GALVANIZED NTS
GB GRAB BAR
GC GENERAL CONTRACTOR 0
GL GLASS OA
GRND GROUND OAE
GWB GYPSUM WALLBOARD oc
GYP GYPSUM OD
OFCI
H H OFF
HG HANDICAP OFOI
HCWD HOLLOW CORE WOOD OH
HDWD HARDWOOD OPP
HDWR HARDWARE
HDR HEADER p
HM HOLLOW METAL PBD
HORZ HORIZONTAL PCC
HR HOUR PED
HT HEIGHT PERF
HTR HEATER PER
HVAC HEATING, VENTILATION, AIR CONDITIONING PERM
HW HOT WATER PERP
PG
I I PH
isc iNTERNATIONAL BUILDING CODE PL
ID INSIDE DIAMETER P-LAM
IN INCH PLWD
INCD INCANDESCENT PNL
INCL INCLUDED POL
INFO INFORMATION PORT
INSUL INSULATION PRNT
INT INTERIOR PROJ
PROP
J J PT
JAN JANITOR PTD
PTW
K K PAV
KD KNOCK DOWN PWR
KO KNOCK OUT
KP KICK PLATE Q
QT
L L QTR
LAB LABORATORY QUAN
LAUN LAUNDRY
LAV LAVATORY R
LF LINEAR FEET R
LIN LINEAR RB
LT LIGHT RCP
RECP
M M RECT
MAS MASONRY RECV
MAT MATERIAL REQ
MAX MAXIMUM RES
MDF MEDIUM DENSITY FIBERBOARD RET
MDO MEDIUM DENSITY OVERLAY REV
MDX MEDIUM DENSITY OVERLAY EXTERIOR GRADE RFPE
MECH MECHANICAL RM
RND
RO
RTU
EQUIPMENT RM
cp 45•.,73•
I I
I I
I I
M s
MANUFACTURER SAN
MINIMUM SB
MIRROR SC
MISCELLANEOUS SCHED
MOULDING SD
MILLWORK SOT
MASONRY OPENING SECT
MODULAR SF
MOUNT SGPL
MOUNTED SHEA
METAL SHT
MULLION SI
SIM
N SPEC
NORTH SPK
NOT IN CONTRACT SPC
NUMBER SQ
NOT TO SCALE ss
STD
0 STL
OVERALL STOR
OR APPROVED EQUAL STR
ON CENTER STRUC
OUTSIDE DIAMETER SUP
OWNER FURNISHED CONTRACTOR INSTALLED SURF
OFFICE sv
OWNER FURNISHED OWNER INSTALLED SYM
OPPOSITE HAND SYN
OPPOSITE
T p 'i'1
PARTICLEBOARD T2
PRECAST CONCRETE TF
PEDESTAL TBD
PERFORATED TEL
PERIMETER TEMP
PERMANENT T&G
PERPENDICULAR TO
PLATE GLASS TOIL
PHASE TOL
PLATE TRD
PLASTIC LAMINATE TWS
PLYWOOD TYP
PANEL
POLISHED u
PORTABLE UBC
PRINTER UON
PROJECT U.S.
PROPERTIES
PRESSURE TREATED V
PAINTED VP
PRESSURE TREATED WOOD VAR
PAVEMENT VB
POWER VCT
VERT
Q VEST
QUARRY TILE VIF
QUARTER
QUANTITY w
WI
R W/0
RADIUS WD
RUBBER BASE WDC
REFLECTED CEILING PLAN W/D
RECEPTION WIN
RECTANGULAR WG
RECEIVING WH
REQUIRED WK
RESILIENT
RETURN
REVISION
REGIONAL FIRE PROTECTION ENGINEER
ROOM
ROUND
ROUGH OPENING
ROOF TOP UNIT
OFFICE
I 2 I l
SANITARY
BACKPAINTED SPANDREL INSULATING GLASS
SOLID CORE
SCHEDULE
SOAP DISPENSER
STATIC DISSIPATIVE TILE
SECTION
SQUARE FEET
STRUCTURAL GRADE PLASTIC LUMBER
SHEATHING
SHEET
SPANDREL INSULATING GLASS
SIMILAR
SPECIFICATION
SPEAKER
SPECIAL
SQUARE
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRAIGHT
STRUCTURAL
SUPPORT
SURFACE
SHEET VINYL
SYMMETRICAL
SYNTHETIC
T
TEMPERED GLASS
TEMPERED INSULATING GLASS
TEMPERED INSULATING W/ APPLIED FILM
TO BE DETERMINED
TELEPHONE
TEMPORARY
TONGUE AND GROOVE
TOP OF
TOILET
TOLERANCE
TREAD
TEACHER WORK STATION
TYPICAL
u
UNIFORM BUILDING CODE
UNLESS OTHERWISE NOTED
UNDERSIDE OF STRUCTURE
V
VAPOR
VARIABLE
VINYL BASE
VINYL COMPOSITE TILE
VERTICAL
VESTIBULE
VERIFY IN FIELD
w
WITH
WITHOUT
WOOD
WOOD W/ COPPER CLADDING
WASHER/DRYER
WINDOW
WIRE GLASS
WATER HEATER
WORK
SYMBOL LEGEND
X'-X"
,r ,r X'-X"
1v k l X'-X" k
OFFICE
[filJ
XXSF
0-
EB
® SYMBOLS LEGEND
1/8" = 1'-0"
LIFE SAFETY CODE SUMMARY:
2018 IBC - ICC INTERNATIONAL CODE
(CONSTRUCTION TYPE - 28)
DIMENSION LINE
ROOM DESIGNATION
ROOM NUMBER
SQUARE FOOTAGE (IF USED)
DOOR AND DOOR
TAG
PARTITION TAG
BREAK MARK
NORTH ARROW
ADAAG - ADA ACCESSIBILITY GUIDELINES
NFPA 101, 2015, NFPA 72- 2015, NFPA 13-2015
BUILDING OCCUPANCY PER IBC BUSINESS GROUP B
SCOPE OF WORK FLOOR AREA
BUSINESS
REQUIRED RATING
OCCUPANT LOAD FACTOR
BUSINESS
2,730 SF
ELECTRICAL RM L------------..J I
I r
100 SF/PERSON
FLOOR AREA
[I]
11\ LIFE SAFETY PLAN
'-V 1/8" = 1'-0"
BATHROOM
[I]
I t
X X X X X X X )lL:: .JX X X X X X X X
I I
I ------------- �------_j XXXX'. XXXXXXXXXXXX L=:x x
LIFE SAFETY PLAN LEGEND:
� ILLUMINATED CEILING MOUNTED EXIT SIGN
• -- ► PATH OF EGRESS
OCCUPANT LOAD
BUSINESS
EXITS REQUIRED
BUSINESS
MAX. ALLOWABLE TRAVEL DISTANCE SHALL
NOT EXCEED 200' (WITHOUT SPRINKLER SYSTEM)
MAXIMUM ALLOWABLE DEAD END
MAXIMUM ALLOWABLE COMMON
PATH OF TRAVEL
MAXIMUM ALLOWABLE TRAVEL DISTANCE
100 GROSS =
MINIMUM
50'
MAXIMUM
100'
250'
OCCUPANT
ACTUAL
ACTUAL
33'
84' r?
f l l J
LJ!:XXX
C7"scALE:
GENERAL NOTES:
PLAN DETAIL TAG
SECTION CUT TAG
ELEVATION/DETAIL
TITLE REFERENCE
ELEVATION DESIGNATION
COLUMN DESIGNATION
GRID LINE
AS USED IN THESE CONTRACT DOCUMENTS:
"FURNISH" MEANS TO PURCHASE AND DELIVER
TO THE PROJECT SITE COMPLETE WITH
NECESSARY APPURTENANCE,
"INSTALL" MEANS TO UNLOAD AT THE DELIVERY
POINT AT THE SITE AND PERFORM EVERY
OPERATION NECESSARY TO ESTABLISH SECURE
MOUNTING AND CORRECT OPERATION AT THE
PROPER LOCATION IN THE PROJECT.
"PROVIDE" MEANS TO "FURNISH" AND "INSTALL."
No.
USDOT/VOLPE
CENTER
55 BROADWAY CENTER
CAMBRIDGE, MA 02142-1001
Description Date
DOT REDESIGN OF
BUILDING #2410
JOINT BASE CAPE COD
SANDWICH, MA
ARCH GENERAL
NOTES, SYMBOLS, &
ABBRV.
SHEET 02
Submission 100% WORKING DOCUMENTS Project number
Date December 5, 2024 Drawn by
Checked by
MINI-SPLIT G-001
Scale As indicated
I
GENERAL DEMOLITION NOTES:
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ADHERE TO THE FOLLOWING:
1. DO NOT CLOSE OR OBSTRUCT THE PATH OF EGRESS, CORRIDORS, OR OTHER OCCUPIED OR USED SPACES OR FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER IF NECESSARY PROVIDE TEMPORARY UTILITIES. PRIOR TO OBSTRUCTION OF EGRESS PATHS OR IMPAIRMENT OF FIRE/LIFE SAFETY COMPONENTS, THE NFPA 241 AND IMPAIRMENTS PLANS MUST BE SUBMITTED FOR APPROVAL BY DESIGN TEAM FIRE PROTECTION ENGINEER WHO IS LICENSED PROFESSIONAL ENGINEER (IN FIRE
PROTECTION ENGINEERING) (DTFPEPE).
2. CEASE OPERATION IF PUBLIC SAFETY OR REMAINING STRUCTURES ARE ENDANGERED. PERFORM TEMPORARY CORRECTIVE MEASURES UNTIL OPERATIONS CAN BE
CONTINUED PROPERLY.
3. IN COMPANY OF THE ARCHITECT AND OWNER, THE CONTRACTOR WILL VISIT THE SITE AND VERIFY THE EXTENT AND LOCATION OF SELECTIVE DEMOLITION REQUIRED PRIOR TO STARTING THE WORK. CAREFULLY IDENTIFY THE LIMITS OF SELECTIVE DEMOLITION. MARK INTERFACE SURFACES AS REQUIRED TO ENABLE THE WORKMEN TO ALSO IDENTIFY THE ITEMS TO BE REMOVED AND STORED, AS WELL AS THE ITEMS TO BE LEFT IN PLACE INTACT.
4. USE MEANS NECESSARY TO PREVENT DUST FROM BECOMING A NUISANCE TO THE PUBLIC, NEIGHBORING BUILDINGS, AND TO ANY OTHER WORK BEING PERFORMED.
5. EXECUTE DEMOLITION WORK TO ENSURE THE SAFETY OF PERSONS AND ADJACENT PROPERTY AGAINST DAMAGE BY DEBRIS. CONTRACTOR WILL TAKE PROTECTIVE
MEASURES TO PREVENT DUST FROM GETTING INTO DUCTS.
6. IN THE EVENT OF DEMOLITION OF ITEMS NOT SCHEDULED TO BE DEMOLISHED, PROMPTLY REPLACE SUCH ITEMS TO THE APPROVAL OF THE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR ANY DAMAGE DONE TO EXISTING FEATURES AS A RESULT OF THIS WORK.
DAMAGED ITEMS SHALL BE REPLACED IN KIND AND AT NO ADDITIONAL COST TO THE OWNER.
7. SHORE, BRACE AND SUPPORT EXISTING CONDITIONS AS REQUIRED FOR REMOVAL OF EXISTING CONSTRUCTION OR INSTALLATION OF THE NEW WORK.
8. COORDINATE THE REMOVAL, RELOCATION, REPLACEMENT, RE-USE, SHUT-OFF, STUB-OFF, CAPPING-OFF OR UPGRADING OF ALL EXISTING PLUMBING, HVAC, ELECTRICAL SYSTEMS, AND TELECOM SYSTEMS EQUIPMENT, AND APPURTENANCES - INCLUDING, BUT NOT LIMITED TO , UTILITY LINES, DUCTS, CONNECTIONS, PANELS, VENTS, FANS, ELECTRICAL BASEBOARD HEAT, PIPING, DEVICES, CONTROLS, SWITCHES, OUTLETS, AND CONDUIT DURING THE CONSTRUCTION AS REQUIRED, AS SCHEDULED OR AS
SPECIFIED IN ACCORDANCE WITH ALL LOCAL, MUNICIPAL, STATE CODES.
9. THE CONTRACTOR SHALL REMOVE AND LEGALLY DISPOSE OF ANY HAZARDOUS MATERIALS AND IN DOING SO SHALL COMPLY WITH ALL APPLICABLE OSHA REGULATIONS AND ALL OTHER FEDERAL, STATE AND LOCAL GUIDELINES REGARDING ASBESTOS-CONTAINING MATERIAL REMOVAL AND DISPOSAL.
10. OWNER AND ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES FOR SAFETY PRECAUTIONS OR FOR THE CONTRACTORS FAILURE TO CARRY OUT THE WORK IN STRICT ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS. OWNER SHALL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTORS OR THEIR AGENTS OR EMPLOYEES OR ANY OTHER PERSONS PERFORMING ANY OF
THE WORK.
11. THE CONTRACTOR SHALL COORDINATE ALL ABOVE CEILING MEP AND STRUCTURAL ELEMENTS PRIOR TO DEMOLITION OF WALLS AND/OR CEILING. CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR FIRE SAFETY DURING PROJECT BEING IN COMPLIANCE WITH IBC, IFC AND NFPA 241.
12. COORDINATE, TERMINATE, AND RELOCATE ALL WALL & CEILING ELECTRICAL (TELECOM/POWER OUTLETS, SWITCHING, THERMOSTAT, ETC.) DEVICES THAT ARE LOCATED ON WALLS & CEILINGS SCHEDULED FOR REMOVAL. GC TO V.I.F. PRIOR TO THE COMMENCEMENT OF WORK. DISCONNECT AND MAKE SAFE EXISTING ELECTRICAL
COMPONENTS TO BE REMOVED.
13. REPAIR, AND LEVEL FLOORING TO MEET MANUFACTURER'S REQUIREMENTS OF THE NEW FLOORING AND WALL MATERIALS AS SPECIFIED. IT IS THE RESPONSIBILITY OF THE GC TO FINISH ALL UNEVEN SURFACES OR PATCH ALL CONCAVE FLOORING TO A LEVEL SURFACE REGARDLESS OF FLOORING UNEVENNESS.
14. PATCH ALL EXISTING WALLS ADJACENT TO ALL WALLS SCHEDULED FOR REMOVAL. PATCHWORK WILL BE CONSISTENT WITH THE WALL RATING.
15. SUBMIT DEMOLITION SCHEDULE FOR APPROVAL INCLUDING SCHEDULE AND METHODS OF CAPPING AND CONTINUING UTILITY SERVICE.
16. THE CONTRACTOR SHALL COMPLY WITH NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS AND 29 CFR 1910.34, COVERAGE AND DEFINITIONS, 29 CFR 1910-35, COMPLIANCE WITH NFPA 101, LIFE SAFETY CODE, 29 CFR 1910-36, DESIGN AND CONSTRUCTION REQUIREMENTS FOR EXIT ROUTES, 29 CFR 1910-37, MAINTENANCE, SAFEGUARDS, AND OPERATIONAL FEATURES FOR EXIT ROUTES.
18. ALL FIRE ALARM NOTIFICATION DEVICES, EXIT SIGNAGE, HEAT DETECTORS, AND EMERGENCY LIGHTING TO REMAIN OPERATIONAL DURING DEMOLITION AND CONSTRUCTION UNTIL WHICH POINT THAT NEW FIRE ALARM SPEAKER STROBE DEVICES ARE READY TO BE INSTALLED AND ACTIVATED.
19. PROTECT ALL EXISTING BUILDING FINISHES AS WORK IS ONGOING.
GENERAL DUST CONTROL
PROVISIONS:
THE GC SHALL PROVIDE DAILY REMOVAL OF ALL DEMOLITION DEBRIS. DO NOT STORE ANY DEMOLITION DEBRIS ON THE FLOOR
OVERNIGHT.
THE GC SHALL MAINTAIN A CLEAN AND SAFE WORK AREA THROUGHOUT THE PERIOD OF DEMOLITION. THE GC SHALL, AT THE END OF EACH WORK DAY, REMOVE ALL DEMOLITION DEBRIS AND HAZARDOUS AND POTENTIALLY DANGEROUS MATERIALS USED IN THE
WORK.
THE GC SHALL CLEAN THE EXTERIOR AREAS IMPACTED BY CONSTRUCTION DUST, DIRT AND DEBRIS ON A DAILY BASIS. THE GC SHALL
BE RESPONSIBLE FOR ALL FEES, PERMITS, ETC., REQUIRED FOR WASTE DISPOSAL
GENERAL NOTES:
AS USED IN THESE CONTRACT DOCUMENTS:
"FURNISH" MEANS TO PURCHASE AND DELIVER TO THE PROJECT SITE COMPLETE WITH NECESSARY APPURTENANCE, ftlNSTALL" MEANS TO UNLOAD AT THE DELIVERY POINT AT THE SITE AND PERFORM EVERY OPERATION NECESSARY TO ESTABLISH SECURE MOUNTING AND CORRECT
OPERATION AT THE PROPER LOCATION IN THE PROJECT.
ftPROVIDE" MEANS TO "FURNISH" AND "INSTALL."
MECHANICAL GRAPHIC SYMBOLS
EQUIPMENT DESIGNATION
SECTION REFERENCES
0 KEYED NOTE SYMBOL
EB INDICATES POINT OF CONNECTION
BETWEEN NEW AND EXISTING
�AIR DEVICE TAG
(SEE SCHEDULE)
I
CFM
@) THERMOSTAT/HUMIDISTAT ,
NOTE: NOT ALL SYMBOLS ARE
USED IN THIS PROJECT
SUPPLY DUCT
RETURN OR OUTSIDE AIR DUCT
� EXHAUST DUCT
[filJ I CEILING AIR DEVICE t SIDEWALL AIR DEVICE = I f f DUCTWORK tlRST FIGURE IS SIDE SHOWN)
I [ f
MANUAL VOLUME DAMPER 12X6 (RECTA GULAR DUCTWORK)
12X6 12"0 (ROUND DUCTWORK) (BO = BACKDRAFT DAMPER)
DUCT DIMENSIONS ARE INSIDE CLEAR
rn
--------------- FLEXIBLE DUCTWORK
I f f f
MOTORIZED DAMPER
11111 FLEXIBLE DUCT CONNECTION r-
I
I ♦so
FD FIRE DAMPER
SD SMOKE DAMPER
I FS COMBINATION FIRE & SMOKE DAMPER
ELECTRICAL GENERAL NOTES:
1. IN GENERAL, CONDUIT ROUTING SHOWN ON THE DRAWINGS IS DIAGRAMMATIC. ACTUAL CONDUIT ROUTING
SHALL BE DETERMINED IN THE FIELD.
2. PENETRATIONS OF CONDUITS, RACEWAYS AND WIRING THROUGH FIRE RATED WALLS AND CEILING SHALL BE FIRE STOPPED USING A FIRE STOPPING U.L. LISTED ASSEMBLY BY A CERTIFIED INSTALLER SO AS TO MAINTAIN THE
UL RATING OF THE ASSEMBLY.
AS USED IN THESE CONTRACT DOCUMENTS:
"FURNISH" MEANS TO PURCHASE AND DELIVER TO THE PROJECT SITE COMPLETE WITH NECESSARY
APPURTENANCE,
3. AS USED IN THESE CONTRACT DOCUMENTS:
"FURNISH" MEANS TO PURCHASE AND DELIVER TO THE PROJECT SITE COMPLETE WITH NECESSARY
APPURTENANCE,
"INSTALL" MEANS TO UNLOAD AT THE DELIVERY POINT AT THE SITE AND PERFORM EVERY OPERATION NECESSARY TO ESTABLISH SECURE MOUNTING AND CORRECT OPERATION AT THE PROPER LOCATION IN THE PROJECT.
"PROVIDE� MEANS TO "FURNISH" AND �INSTALL."
g
GFI
8c
[] 30/3
15AF
0-i cp
IT]
DUPLEX RECEPTACLE - 15" TO CENTER AFF UNLESS OTHERWISE NOTED
GFI = GROUND FAULT CIRCUIT INTERRUPTING
D = DEDICATED CIRCUIT
EWC = GFI FOR ELECTRIC WATER COOLER
TV = TELEVISION, 80" TO CENTER AFF
COUNTERTOP DUPLEX RECEPTACLE - OR MOUNTED AT 44" AFF WHERE NO
COUNTER EXISTS
DOUBLE DUPLEX RECEPTACLE - 15" AFF UNLESS OTHERWISE NOTED
SPECIAL PURPOSE OUTLET - 18" AFF UNLESS OTHERWISE NOTED
MOTOR
DISCONNECT SWITCH - 30/3 = SWITCH AMPS/POLES,
15AF = 15 AMP FUSE
JUNCTION BOX - # INDICATES CIRCUIT
BRANCH CIRCUIT PANELBOARD
DISTRIBUTION PANELBOARD
FUSIBLE COMBINATION FVNR MOTOR STARTER
GROUND BAR WITH INSULATED SPACERS. GROUND BAR SHALL BE 1/4"X2"X12"
COPPER MINIMUM WITH NEMA TWO HOLE LUG SPACING. INSTALL AT 24" ABOVE
FLOOR. SEE DETAIL ON SHEET E-501.
SINGLE RECEPTACLE UNDER SINK FOR GARBAGE DISPOSAL
DRY TYPE TRANSFORMER
CONDUIT
� CONDUIT AND WIRING HOMERUN.
� SHORT STROKE INDICATES PHASE CONDUCTOR.
� LONG STROKE INDICATES NEUTRAL CONDUCTOR.
LONG STROKE WITH DOT INDICATES EQUIPMENT GROUND CONDUCTOR.
MISCELLANEOUS
�1u '\J7
EQUIPMENT DESIGNATION
0--- KEYED NOTE
OFFICE --
ROOM NAME
DI]..______ ROOM NUMBER
AFF
FMCP
FVNR
TV
ABBREVIATIONS
ABOVE FINISHED FLOOR
FIRE ALARM MASS NOTIFICATION CONTROL PANEL
FULL VOLTAGE NON-REVERSING
TELEVISION
No.
US DOT/VOLPE
CENTER
55 BROADWAY CENTER
CAMBRIDGE, MA 02142-1001
Description Date
DOT REDESIGN OF
BUILDING #2410
JOINT BASE CAPE COD
SANDWICH, MA
DEMOLITION,
ELECTRICAL, &
MECHANICAL NOTES,
SYMBOLS, & ABBREV
SHEET 03
Submission 100% WORKING DOCUMENTS Project number
Date December 5, 2024 Drawn by
Checked by
MINI-SPLIT G-002
Scale 1/8" = 1'-0"
I i i I i i I i i i i i i i
STORAGE MECHANICAL RM (130SF x 14ft high to roof deck= 1820CF)
SHOWER ROOM dimensions 112SF x 14ft high to roof deck = 1568 CF -uninsulated e�terior CMU walls v1
-roofhas5"ofrigidinsulation
II
rs.=z==:sz 1z::c��===q1
ELECTRICAL RM
[I]
130SF
, " . SHOWER ROOM �
� G
FURNISH WALL
MOUNTED&
HARDWIRED
ZONE4
THERMOSTAT
112SF
EXISITING
� ����JosTAT i BATHROOM i
EQUIPMENT RM
3 JX X
HVAC
ZONE1
1266 SF
X X
OFFICE
500 SF
' [I] ! ----------------------------------------------------------------------------------------------------------------------------------------------------------------------
CD CONTROL SYSTEM: NEW HVAC THERMOSTATS & HVAC ZONES PLAN 1 1/8" = 1'-0"
FURNISH MINI-SPLIT
DUCTLESS BLOWER UNIT
FOR ZONE 4
(WALL MOUNTED) / 1
/ II
II
fiF��=z;;z==;==rzs,���r=r==r=��r==tu7===r���r=lkl I I,,, � b b'
J
_;--=- 1 I\
I
1 r
II i\ J ._,,. '-LJ ,,i "'\__ EXISTING DUCTWORK & RTU-1.
FURNISH MINI-SPLIT DUCTLESS
CONDENSER UNIT "A"
(FREE STANDING)
@ NEW MECHANICAL FLOOR PLAN
1/8" = 1'-0"
0 WEST SIDE 4 1/8" = 1'-0"
® EAST SIDE5 1/8" = 1'-0"
NEW MECHANICAL LEGEND:
= NEW DUCT
..,_ FLEX DUCT
� SUPPLY
[Z] RETURN
� EXHAUST
Q COMBINATION THERMOSTAT/
V HUMIDISTAT
� AIR DEVICE TAG
'--01/� (SEE SCHEDULE)
CFM
ETR = EXISTING TO REMAIN
CT= CURRENT TRANSDUCER
SD = SMOKE DAMPER
M = MOTOR
VFD = VARIABLE FREQUENCY DRIVE
DX= DIRECT EXPANSION
RTU = ROOFTOP UNIT
ADJ = ADUST ABLE
DEMO= DEMOLITION
AFF = ABOVE FINISHED FLOOR
LT = LOW TEMPERATURE ALARM
@) EXISTING OVERHEAD DUCTWORK FROM ROOFTOP UNIT (RTU-1)
3 SCALE: NTS
LEAD PROFESSIONAL FIRM
102 SOUTH STREET
SUITE 3
BOSTON MA 02111
P: 617-951-2700 F: 617-951-2705
No.
USDOT/VOLPE
CENTER
55 BROADWAY CENTER
CAMBRIDGE, MA 02142-1001
Description Date
DOT REDESIGN OF
BUILDING #2410
JOINT BASE CAPE COD
SANDWICH, MA
HVAC FLOOR PLAN
SHEET 04
Submission
Project number
Date
100% WORKING DOCUMENTS
147001.00
December 5, 2024 Drawn by
Checked by
MINI-SPLIT M-101
Scale As indicated
EXISTING SINK FOR CONDENSATE DRAIN
Brian Hanley Line
Brian Hanley Line
Brian Hanley Rectangle
Brian Hanley Oval
Brian Hanley Rectangle
Brian Hanley Rectangle
Brian Hanley Rectangle
Brian Hanley Rectangle
Brian Hanley Line
Brian Hanley Rectangle
Brian Hanley Rectangle
Brian Hanley Rectangle
/ 71
/ II
�J
PANEL -MOP --,_ ::C
'-4
PANEL-RP
GENERAL NOTES:
1. SEE THE MECHANICAL SHEETS FOR EXACT EQUIPMENT LOCATIONS
GENERAL NOTES:
AS USED IN THESE CONTRACT DOCUMENTS:
"FURNISH" MEANS TO PURCHASE AND DELIVER TO THE PROJECT SITE COMPLETE WITH NECESSARY APPURTENANCE, ft w
"INSTALL" MEANS TO UNLOAD AT THE DELIVERY POINT AT THE SITE AND PERFORM EVERY OPERATION NECESSARY TO ESTABLISH SECURE MOUNTING AND CORRECT
OPERATION AT THE PROPER LOCATION IN THE PROJECT.
"PROVIDE" MEANS TO "FURNISH" AND "INSTALL."
,r I�
Q) i::-.=-..=i -7
I
J :::_.-;_-=i
USDOT/VOLPE
CENTER
55 BROADWAY CENTER
CAMBRIDGE, MA 02142-1001
���0 No. Description Date
DOT REDESIGN OF
BUILDING #2410
JOINT BASE CAPE COD
SANDWICH, MA
ELECTRICAL FLOOR
PLAN
SHEET 05
Submission
Project number
Date
100% WORKING DOCUMENTS
147001.00
December 5, 2024
Drawn by
Checked by
MINI-SPLIT E-101
Scale
MDP
Connected Loads By Phase (VA) Total Connected Loads By Type (VA) Demand Factors Total Demand Loads By Type (VA)
Total 55,597 Subtotal 50,773
Total Demand Load 63,466
Total Demand Amps 176
RP
Connected Loads By Phase (VA) Total Connected Loads By Type (VA) Demand Factors Total Demand Loads By Type (VA)
Total 27,813 Subtotal 24,539
Total Demand Load 30,674
Total Demand Amps 85
5, 4
No. Description Date