MIL-PRF-27210J.pdf

PDF 488 KB Posted

Attached to
AVIATOR’S BREATHING OXYGEN (ABO) AND NITROGEN, TECHNICAL (LN2) MULTIPLE OCONUS EUROPE LOCATIONS
Solicitation number
SPE601-20-R-0324
Issued by

View the file

Other files

File Type Posted
Lakenheath.pdf PDF
NSA Souda Bay Navy.pdf PDF
Aviano.pdf PDF
Rota Naval Station.pdf PDF
Moron AB.pdf PDF
QAPs.pdf PDF
ENERGY QAP E6 CERTIFICATE OF CONFORMANCE (AUG 2015).pdf PDF
NSA Souda Bay AF.pdf PDF
Ramstein.pdf PDF
Mildenhall.pdf PDF
TRANS CERT.pdf PDF
Spangdahlem.pdf PDF
Incirlik.pdf PDF
SPE60120R0324 ABO LN_14 Jan 21.pdf PDF
Aerospace Text APG_SPE60120R0324 ABO LN.pdf PDF
Fairford.pdf PDF
NAS Sigonella.pdf PDF
Lajes Field.pdf PDF
Contractor Performance Data Sheet.pdf PDF
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MIL-PRF-27210J

7 August 2013

SUPERSEDING

MIL-PRF-27210H

01 October 2009

PERFORMANCE SPECIFICATION

OXYGEN, AVIATOR’S BREATHING, LIQUID AND GAS

AMSC N/A FSC 6830

METRIC

Comments, suggestions, or questions on this document should be addressed to AFPA/PTPT, 2430 C Street, Bldg 70, Area B, Wright-Patterson AFB OH 45433-7632 or e-mailed to AFPA.PTPS@wpafb.af.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https://assist.dla.mil.

Downloaded from http://www.everyspec.com

This specification is approved for use by all Departments and Agencies of the Department of Defense.

1. SCOPE

1.1 Scope. This specification covers the requirements for two types of aviator’s breathing oxygen.

1.2 Classification. Oxygen is classified as the following types, as specified (see 6.2).

Type I - Gaseous

Type II - Liquid

1.3 Part or identifying number (PIN). The PINs to be used for oxygen acquired to this specification are created as follows:

M 27210 - X - XX - XXX Example of PIN: M27210-1-22-202

Pressure (in pounds/inch2, gauge) psig/10 (Type I only)

Cubic feet/10 (Type I only)

Type (see 1.2.1). Use 1 for type I; 2 for type II

Specification number

Prefix for military specification

2. APPLICABLE DOCUMENTS

2.1 General. The documents listed in this section are specified in sections 3, 4 and 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4 or 5 of this specification, whether or not they are listed.

2.2 Government documents.

2.2.1 Specifications, standards, and handbooks. The following specifications, standards and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

DEPARTMENT OF DEFENSE STANDARDS

MIL-STD-101 Color Code for Pipelines and for Compressed Gas Cylinders

MIL-STD-1411 Inspection and Maintenance of Compressed Gas Cylinders

COMMERCIAL ITEM DESCRIPTIONS

A-A-59860 Valves, Cylinder, Gas (For Compressed or Liquefied Gases)

(Copies of these documents are available online at https://assist.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094)

2.3 Non-government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

ASTM INTERNATIONAL (ASTM)

ASTM E29 Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications (DoD Adopted)

ASTM F307 Standard Practice for Sampling Pressurized Gas for Gas Analysis (DoD Adopted)

ASTM F310 Standard Practice for Sampling Cryogenic Aerospace Fluids (DoD Adopted)

(Copies of these documents are available online at http://www.astm.org or the ASTM International, 100 Barr Harbor Drive, West Conshohocken PA 19428-2959)

COMPRESSED GAS ASSOCIATION (CGA)

CGA G-4.3 Commodity Specification for Oxygen

CGA P-15 Filling of Industrial and Medical Nonflammable Compressed Gas Cylinders

(Copies of these documents are available online at http://www.cganet.com or the Compressed Gas Association, Inc., 14501 George Carter Way, Suite 103, Chantilly VA 20151, USA)

2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.

3. REQUIREMENTS

3.1 First article. When specified, a sample shall be subjected to first article inspection in accordance with 4.2 (see 6.2).

3.2 Purity. The oxygen (Type I and II) shall contain not less than 99.5 percent oxygen by volume when tested in accordance with 4.5. The remainder, except for moisture and minor constituents specified in Table I, shall be argon and nitrogen.

3.3 Impurities. The oxygen shall be free from all contaminants of known toxicity to the maximum practicable extent. Limitations on specific impurities shall be as follows:

3.3.1 Odor. The oxygen (Type I and II) shall contain no odor when tested as specified in 4.5.

3.3.2 Minor constituents. Minor constituents of Types I and II shall not exceed the quantity specified in Table I.

3.3.3 Moisture. Moisture in Types I and II shall not exceed 7 ppm of water vapor or a maximum dew point of -63.3°C (-82°F) when tested as specified in 4.5.

3.4 Materials. There is no requirement included herein which should be interpreted to exclude the use of reclaimed materials in the manufacture of this commodity.

3.5 Filter. When required, Type II oxygen shall be passed through a filter as specified in 4.6.

3.6 Limiting values. The following applies to all specified limits in this specification: For purposes of determining conformance with these requirements, an observed value or a calculated value shall be rounded off in the last right-hand digit used in expressing the specification limit, using the Rounding Method of ASTM E29.

3.7 Gas Cylinders (Type I only).

3.7.1 Pressure. The container filling pressure (see 6.2) shall not differ from that required by the contract by more than 1.0% at 21°C (70°F) when tested as specified in 4.4.1. In no case shall the filling pressure exceed the rated service pressure of the container. Pressure-Temperature Filling Charts in CGA P-15 may be used.

3.7.2 Leakage. Cylinders shall not leak when tested according to 4.4.2.

3.7.3 Inspection and maintenance. Compressed gas cylinders shall be inspected, maintained and charged according to 4.4.3.

TABLE I. Constituent concentrations

Constituent Maximum concentration in parts per million (by volume)

Type I Type II

Carbon Dioxide (CO2) 10 5

Methane (CH4) 50 25

Acetylene (C2H2) 0.1 0.05

Ethylene (C2H4) 0.4 0.2

Ethane (C2H6) and other hydrocarbons as ethane equivalents

6 3

Nitrous Oxide (N2O) 4 2

Refrigerants and Similar Solvents1:

Hydrochlorofluorocarbons (HCFC) Hydrofluoroethers (HFE) Chlorofluorocarbons (CFC)

Other Solvents: Trichloroethylene, n-Propyl Bromide, Trichloroethane, Carbon Tetrachloride, Perchloroethylene, Dichloromethane, Perfluoro-n-Butyl-Iodine

(PFBI)

0.2 0.1

Other Compounds2: (each discernible from background noise on infrared spectrophotometer or gas chromatograph)

0.2 0.1

Note 1: Examples of Refrigerants and Similar Solvents include, but are not limited to the following compounds: HCFC: HCFC-225 (all isomers), HCFC-141b, HFE: HFE-7100, CFC: Freons

Note 2: Examples of Other Compounds include, but are not limited to, Carbon Monoxide (CO) and Sulfur Hexafluoride (SF6)

4. VERIFICATION

4.1 Classification of inspections. A cross reference between the individual inspections and test methods is provided in Table II. The inspection requirements specified herein are classified as follows:

a. First article inspection (see 4.2).

b. Periodic inspection (see 4.2).

c. Quality conformance inspection (see 4.2).

TABLE II. Test requirements

Characteristic

First Article Inspection

Periodic Inspection

Quality Conformance

Inspection

Inspection Paragraph

Test Method

Paragraph Purity – Type I Required Required Required 3.2 4.5 Purity – Type II Required Required1 Required 3.2 4.5 Odor Required Required Required 3.3.1 4.5 Minor Constituents Required Required Not Required Table I 4.5 Moisture Required Required1 Required 3.3.3 4.5 Filled Containers (Type I) Pressure Leakage

Required

3.7.1 3.7.2

4.4.1 4.4.2

Note 1: Reported for correlation purposes only.

4.2 First article, periodic, and quality conformance inspections.

4.2.1 First article inspection. First article inspection shall be defined as a preproduction sample.

Prior to initial delivery of Type I or Type II oxygen, a representative product specimen shall be obtained as specified in 4.3.1.1 (Type I) or 4.3.1.2 (Type II) and forwarded to the designated laboratory (6.2). The product shall meet the requirements in 3.2 and 3.3.

4.2.2 Periodic inspection. A representative product specimen of oxygen shall be obtained as specified in 4.3.1.1 (Type I) or 4.3.1.2 (Type II) and shall be taken once every 60 calendar days for the duration of the contract. This sample shall be shipped to the specified laboratory (6.2) for testing to determine compliance with requirements specified in Table II. The specified laboratory shall also test for purity and moisture if there is sufficient sample. The purity results for Type II oxygen and the moisture results for Type I and Type II oxygen shall be reported for correlation purposes and shall not be used to determine compliance to requirements of 3.2 or 3.3.3.

4.2.3 Conformance inspection. Quality conformance inspection shall consist of the following:

a. Individual container / cylinder inspection (see 4.2.3.2).

b. Sampling inspection per lot (see 4.2.3.3).

4.2.3.1 Place of inspection. Quality conformance inspection shall be performed at source.

4.2.3.1.1 Type I oxygen. Quality conformance inspection on cylinders filled with Type I oxygen shall be performed at the site of filling (see 6.2).

4.2.3.1.2 Type II oxygen. Quality conformance inspection shall be performed on samples taken from Type II oxygen transport container prior to leaving the site of filling. The transport container shall not be permitted to take on further liquid oxygen between inspection at the filling point and arrival at its destination, unless all quality conformance inspections are performed on the contents after such filling.

4.2.3.2 Individual container / cylinder inspection. Individual inspection will be as follows.

4.2.3.2.1 Type I Individual Inspection. Each cylinder filled with Type I oxygen shall be subjected to the tests in Table III.

4.2.3.2.2 Type II individual inspection. After filling the shipping container, two product specimens shall be drawn from each container. One specimen shall be in liquid state and subjected to the odor test specified in 4.5. The other specimen shall be vaporized and subjected to the tests in Table III, as specified in 4.5.

TABLE III. Individual inspection

TEST TYPE I TYPE II

Leak test 4.4.2 ---

Odor test --- 4.5

Purity test --- 4.5

Moisture test --- 4.5

4.2.3.3 Sampling inspection per lot. Randomly selected samples of Type I oxygen as specified in Table IV shall be subjected to the following inspection:

Odor test 4.5

Fill pressure 4.4.1

Purity 4.5

Moisture 4.5

The fill pressure shall be performed prior to the odor, purity, and moisture tests. The cylinder pressure shall be checked after completion of all tests. If the sample cylinder pressure is below the minimum acceptable value, the cylinder shall be filled to within the acceptable range.

4.2.3.4 Lot definition. Each set of Type I oxygen cylinders filled on the same manifold at the same time shall constitute a lot.

TABLE IV. Sampling for test

Number of containers in lot Number of containers to be sampled

1 1

2 - 40 2

41 – 70 3

71 - over 4

4.3 Sampling. Samples required by 4.2.1 and 4.2.2 shall be delivered to the designated Government Laboratory (see 6.4), another designated laboratory, or other laboratories authorized by AFPA/PTPT, 2430 C Street, Bldg 70, Area B, Wright-Patterson AFB OH 45433-7632.

4.3.1 Sampling point. The sampling point will be as follows:

4.3.1.1 Type I oxygen. Samples shall be taken from the manifold during filling operations.

4.3.1.2 Type II oxygen. Samples shall be taken from Type II oxygen storage tanks at the manufacturing site or any distribution facilities. If a distribution facility is supplied from more than one storage or manufacturing facility, each facility shall be checked as specified above.

4.3.2 Sampling method. Unless otherwise specified (see 6.2), oxygen shall be sampled according to the methods of Table V. Sample size shall be sufficient to provide the analyzer with 7 liters of oxygen at 10 atmospheres of pressure.

4.3.2.1 Sample identification. The following data shall be provided on each sample sent to a Government laboratory for analysis: Item name, specification number, Type (I or II), sample number, sampler serial number, contractor's name, address, phone number and return shipping address for sampler, Government representative's name, address, and phone number, reason for analysis (first article, periodic, or resample), contract number, and date sample taken.

TABLE V. Sampling particulars

Sampler Oxygen type Method Recommended final pressure (gauge)

≈ 1 liter size or larger Gas Cylinder

I ASTM F307 ≈12,500 kPa (≈ 1800 psi)

TTU-131/E, Cosmodyne

LLC

II ASTM F310 2750 to 3450 kPa (400 to 500 psi)

FCS 2001, CV

International

II ASTM F310 5500 to 8300 kPa (800 to 1200 psi)

4.4 Cylinders of Type I oxygen.

4.4.1 Filling pressure. Containers shall be stabilized to 21°C (70°F). Containers shall be tested for proper filling pressure by attaching a calibrated Bourdon-tube gauge or calibrated electronic equivalent gauge to the valve outlet. The gauge shall have scale divisions not greater than 100 kPa (15 psi). Then the valve shall be opened and the internal pressure observed on the gauge. If the internal pressure differs from the applicable filling pressure value by more than 100 kPa (15 psi), the container, and all other containers filled from the same manifold at the same time, shall be rejected.

4.4.2 Leakage. Each Type I oxygen container shall be tested for leaks at the neck threads, stem packing, and safety device of the valve with leak detection fluid. Valve seat leakage shall be tested after filling has been completed by connecting a hose to the valve outlet and placing the other end of the hose under the surface of a liquid. Methods of leak detection and/or the leak check guidance in CGA P-15 may also be used.

4.4.3 Inspection and maintenance. Compressed gas cylinders shall be inspected, maintained and charged according to MIL-STD-1411.

4.4.3.1 Valves. Valves shall conform to A-A-59860.

4.4.3.2 Color coding. Government-owned cylinders shall be color coded according to

MIL-STD-101.

4.4.3.3 Identification tag. An identification tag impervious to climatic conditions shall be wired to the outlet port of each container and shall contain the following information: Product name, specification number with revision letter, type designation, National Stock Number (NSN), quantity, name of manufacturer, name of contractor (if different from manufacturer), date of manufacture, and lot identification number.

4.5 Analytical procedures. Unless otherwise specified, samples shall be analyzed according to the procedures described in CGA G-4.3 (see 6.2). Calibration gas standards may be required to calibrate (zero and span) analytical instruments used to determine the purity and impurity contents of the oxygen.

The accuracy of the calibration gas standards is to be traceable to the National Institute of Standards and Technology (NIST).

4.5.1 Documentation of procedures. Written procedures that detail the sampling and testing program and the analytical and measuring equipment calibration program shall be maintained.

4.5.2 Test reports. Test reports shall accompany each shipment and may be provided on the contractor's internal form, a letter of transmittal, the product DD Form 250, or Wide Area Work Flow (WAWF) electronic form. For Type I, the reports shall include the values obtained from the odor, fill pressure, purity and moisture tests. For Type II, the reports shall include the values obtained from the odor, purity, and moisture tests.

4.6 Filtration of Type II Oxygen. When required, Type II oxygen shall be passed through a filter with a rating of at least 10-micrometer nominal (40-micrometer absolute) located in the fill line to the shipping container.

5. PACKAGING

5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging requirements are maintained by the Inventory Control Point’s packaging activities within the Military Service or Defense Agency, or within the military service’s system commands. Packaging data retrieval is available from the managing Military Department’s or Defense Agency’s automated packaging files, CD-ROM products, or by contacting the responsible packaging activity.

6. NOTES

(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)

6.1 Intended use. The oxygen covered by this specification is intended for use in military aircraft breathing oxygen systems.

6.2 Acquisition requirements. Acquisition documents should specify the following:

a. Title, number, and date of this specification.

b. Type of oxygen required (see 1.2)

c. First article inspection will be performed as specified in 4.2.

d. The name and address of the laboratory to which the representative product specimen is to be submitted (see 4.2, 6.4, and Table VI).

e. When variation in points of inspection are granted (see 4.2.3.1).

f. When variation in sampling method is granted (see 4.3.2).

g. When a variation in analytical procedures is granted (see 4.5).

h. Packaging requirements (see 5.1 and 6.3).

i. Cylinder size, capacity and fill pressure (as determined by cylinder size and capacity).

j. When cleaning and repair schedule is required for leased or Government owned containers.

k. Method of shipment.

l. A hydrostatic and/or ultrasonic testing, cleaning, and repair schedule for cylinders that meets current DOT requirements.

6.2.1 Inspection at source. DLA Energy awarded contracts will delegate Contract Quality Assurance (CQA) to DLA Energy QARs.

6.3 Over-packing Samplers for transport should be suitably packaged in accordance with ATA and DOT regulations to protect them during shipment. The packaging should be inspected and those with large amounts of wear or damage should be replaced to ensure prompt shipment to and from the laboratory.

6.4 Government laboratories. These laboratories participate in the Air Force Aviator's Breathing Oxygen Correlation Program. Contracting officers may obtain a list of approved Government laboratories by contacting to the AFPA/ PTPT, 2430 C Street, Bldg 70, Area B, Wright-Patterson AFB OH 45433- 7632. See also Table VI.

TABLE VI. Laboratories

CALIFORNIA Aerospace Fuels Laboratory

AFPA/PTPLE

1747 Utah Ave, Bldg 6670 Vandenberg AFB CA 93437-5220

JAPAN

(KADENA AB)

Aerospace Fuels Laboratory

AFPA/PTPLG

Bldg 854 Kadena Air Base, Okinawa JA

APO AP 96368-5162

FLORIDA Aerospace Fuels Laboratory

AFPA/PTPLH

15251 Scrub Jay Street Bldg 54800 Cape Canaveral AFS FL 32920-7519

OHIO Aerospace Fuels Laboratory

AFPA/PTPLA

2430 C St, Bldg 70, Area B

WPAFB OH

45433-7632

UNITED KINGDOM

(RAF MILDENHALL)

Aerospace Fuels Laboratory

AFPA/PTPLF

Bldg 725, RAF Mildenhall UK

APO AE 09459-5025

6.5 Particulate contamination. Particulate matter may be introduced and accumulate during transfer and storage of oxygen. Recommend that users control particulate matter by the installation of filters in oxygen transfer lines.

6.6 Subject term (key word) listing.

Aerospace

Code, Color

Contaminant

Cryogenic

Cylinder

Filling pressure

Solvent

Spectroscopy, Infrared

Valve

6.7 International standardization agreement implementation. This specification implements certain provisions of ASIC AIR STD 15/14, Breathing Oxygen Characteristics (Including Supply Pressure and Hoses), and NATO STANAG 7106, Characteristics Of Gaseous Breathing Oxygen, Liquid Breathing Oxygen And Supply Pressures, Hoses And Replenishment Couplings. When amendment, revision, or cancellation of this specification is proposed, the preparing activity must coordinate the action with the U.S. National Point of Contact for the international standardization agreement, as identified in the ASSIST database at https://assist.dla.mil.

6.8 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes.

CONCLUDING MATERIAL

Custodians: Preparing activity:

Army – AV Air Force – 68 Navy – AS (Project 6830 - 2013 - 004) Air Force – 68

DLA – PS

Review activities:

DLA – GS

Air Force – 11 Air Force – 71

Civil Agencies:

NASA – NA

Note: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information using the ASSIST Online database at https://assist.dla.mil.

A-A-59155 5 March 2003

- 1 -

METRIC

COMMERCIAL ITEM DESCRIPTION

NITROGEN, HIGH PURITY, SPECIAL PURPOSE

1.0 ABSTRACT

This document provides the requirements for the procurement of gaseous or liquid primary grade nitrogen suitable for use in reactor plant, steam plant and shipyard applications where high purity nitrogen is required.

2.0 SOURCES OF REFERENCE DOCUMENTS

The list of documents and specifications pertinent to this commercial item description is provided in Table 3 of this document.

3.0 TECHNICAL REQUIREMENTS

3.1 Material Requirements

The nitrogen shall conform to the type, grade and class specified in Table A below.

Type I nitrogen shall contain no solid particles whose maximum dimensions are greater than 50 microns in size assured by the use of a 10 micron or better filter at or close to the cylinder charging manifold that is capable of removing foreign material.

Beneficial comments, (recommendations, additions, deletions) and any pertinent data which may be used in improving this document should be addressed to: Commander, Naval Sea Systems Command, ATTN 05Q, 1333 Isaac Hull Avenue SE, STOP 5160, Washington Navy Yard, DC 20376-5160.

AMSC N/A FSC 6830

DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.

- 2 -

Table A

Characteristics for Type I-Gaseous and Type II-Liquid Nitrogen

Characteristic Grade Requirement

Purity A B

99.95 % Minimum by Volume

99.50 % Minimum by Volume

Argon, Neon & Helium All Includes Trace Quantities

Oxygen Content A B

0.05 % Maximum by Volume

0.50 % Maximum by Volume

Moisture Content All 0.02 mg/L Maximum Oil All Oil Free Odor All None Hydrocarbon Content All < 50 ppm as Methane by Volume Particulate Content All < 50 Microns in Size

3.2 Manufacturing and Process Requirements

3.2.1 Mercury Contamination

The nitrogen shall not contain and shall not be contaminated by mercury or mercury compounds. During the manufacturing process, tests and inspections, the product shall not have come in direct contact with mercury, nor any of its compounds, nor any mercury containing device employing a single boundary of containment.

3.2.2 Foreign Material Exclusion

The nitrogen shall be free from foreign material such as oil, grease, dirt and debris.

Production operations shall be conducted so as to assure the required level of cleanliness. Such operations may include but are not limited to the following precautions: Ensuring that the nitrogen containers are free from foreign material prior to fill, providing an area for fill operations that is free of dirt and debris, and maintaining the fill equipment in a clean condition.

3.2.3 Container Requirements

New cylinders shall conform to the requirements of FED-RR-C-901. Used or Government furnished cylinders shall conform to the requirements of MIL-STD-1411 and 49 CFR 100-199 prior to refilling. Cylinders are to be color coded according to MIL-STD-101. Type II liquid nitrogen shall be contained in either supplier owned or Government owned insulated containers in accordance with 49 CFR 171-190.

- 3 -

3.2.4 Valve Requirements

Cylinder valves shall conform to the requirements of MIL-DTL-2, Valve Outlet Application 580 for cylinders with rated pressures less than 3000 psig and Application 680 for cylinders with rated pressures greater than 3000 psig.

3.2.5. Lot Size Requirements

A lot is defined as all nitrogen produced during a consecutive 24-hour period from the same source, by one manufacturer, at one plant, from the same materials, and under essentially the same manufacturing conditions provided the operation is continuous. A source is considered to be either an individual nitrogen producing process or an individual storage container to which no nitrogen is added after the initial filling.

In the event the process is a batch operation, each batch (see 3.2.6 below) shall constitute a lot. Even if a batch is larger, each lot of Type I nitrogen cylinders ready for delivery shall be limited to a maximum of 500 cylinders. For Type II liquid nitrogen, each individually filled container shall be considered a lot.

3.2.6 Batch Requirement

That quantity of material which has been manufactured by some unit chemical process.

3.2.7 Processing Requirements

Type I gaseous nitrogen shall be manufactured by any process known not to introduce oil into the nitrogen. Type I gaseous nitrogen shall be compressed with a water-lubricated or dry-seal compressor or produced using a cryogenic converter from a liquid nitrogen source. Cylinders shall be filled using a 10-micron or better filter, positioned at or close to the cylinder charging manifold, that is capable of removing both oil and solid particulates.

The settled pressure in a filled container shall be within 25 psig of the pressure that corresponds to the settled container temperature as shown on Table 2.

4.0. QUALITY ASSURANCE PROVISIONS

4.1 Inspection System Requirements

The vendor shall maintain complete records for all inspections and tests performed on the product. The records shall be traceable by the vendor's lot or batch number. These records shall indicate the nature and number of observations made, the number and type of deficiencies found, the quantities approved and rejected, and the specific actions taken to correct the deficiencies.

- 4 -

4.2 Test Equipment Requirements

All gages, measuring and test equipment used in the tests, inspection and processing of the product shall be calibrated to certified standards that have known, valid relationships to nationally accepted industry standards. The calibration frequency for each device shall be based on its stability, purpose and usage. A positive means (such as stickers) shall be provided to identify the calibration interval, last date of calibration and date calibration is due for each device. Complete written records of calibration data traceable to the individual test devices shall be available for Contracting Agency review.

4.3 Contract Certification Requirements

The contractor shall certify and maintain substantiating evidence that the product offered meets the salient characteristics of this Commercial Item Description in accordance with the required frequency of testing specified in Section 3.2.5 and that the product conforms to the producer’s own drawings, specifications, standards, and quality assurance practices, and is the same product offered for sale in the commercial marketplace. The Government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be provided for under the provisions of the contract.

4.4 Inspection Requirements

Sampling for visual inspection of Type I containers shall be performed on those containers that are ready for delivery. Samples shall be chosen randomly and in accordance with Table 1.

Type I containers should be sampled from near the beginning and end of the production run, and if more than two containers are required, from points in between. Type II containers shall be visually inspected individually.

Table 1

Sampling Requirements For Type I Containers

Lot Size Number of Containers

≤ 25 2

26 to 150 3

151 to 500 5

Each selected container shall be inspected for conformance with the requirements specified in Section 3.2.3 (Container Requirements), Section 3.2.4 (Valve Requirements), Section 5.0 (Shipping Requirements) and Section 6.0 (Marking Requirements) of this description. Failure of any one container constitutes failure of the entire lot. A failed lot may be resubmitted for inspection provided the vendor has corrected all the non-conforming attributes.

- 5 -

4.5 Testing Requirements

Sampling for testing of a lot of Type I gaseous nitrogen shall be from containers that are ready for delivery in accordance with the requirements specified in Section 4.4 of this specification.

Sampling for testing of a container of Type II liquid nitrogen shall be in accordance with ASTM F 310. Before any test is performed, sufficient nitrogen shall be permitted to flow to displace any other gas present in the test equipment lines. Liquid nitrogen shall be in the vapor form when tested. The following tests shall be performed on each sample selected for testing per the designated procedure. Acceptance criteria are as specified:

Characteristic Test Method Acceptance Limit

Purity CGA G-10.1 Grade A 99.95 % Minimum by Volume Grade B 99.50 % Minimum by Volume

Oxygen Content CGA G-10.1 Grade A 0.05 % Maximum by Volume Grade B 0.50 % Maximum by Volume

Moisture Content CGA G-10.1 Grade A 0.02 *mg/L Maximum Grade B 0.02 *mg/L Maximum

Odor CGA G-10.1 None Detectable Hydrocarbon Content CGA G-10.1 <50 ppm as Methane by Volume Leakage (Type I Only) MIL-STD-1411 None

* Note: The 0.02 milligram water per liter of gas is equivalent to 26.3 ppm water vapor by volume and also to a dewpoint of minus 63.5 degrees Fahrenheit.

5.0 SHIPPING REQUIREMENTS

The shipment of nitrogen containers shall be in accordance with 49 CFR 171-190. Containers shall conform to the Uniform Freight Classification, National Classification Board or regulations of other carriers as applicable to the mode of transportation. Palletization of containers shall be in accordance with MIL-HDBK-774.

A Material Safety Data Sheet (MSDS) prepared per FED-STD-313 shall be provided with each pallet and affixed/packaged in a manner for easy accessibility without being lost or damaged during shipment and storage. In accordance with 29 CFR 1910.1200, one copy of the MSDS shall be provided with the bill of lading for each shipment of material.

6.0 MARKING REQUIREMENTS

Containers of nitrogen shall be marked in accordance with 49 CFR 171-190 and MIL-STD-129 specifically having the type and grade either stenciled or tagged on the container.

Preparing Activity:

Navy – SH

(Project 6830-1061)

- 6 -

Table 2

Pressure-Temperature Conversion Chart for Nitrogen

Settled Temp F 1800 psig 2015 psig 2200 psig 2265 psig 2400 psig 3500 psig

-50 1270 1407 1528 1574 1653 2385 -48 1279 1417 1540 1588 1667 2404 -46 1288 1427 1552 1601 1680 2423 -44 1297 1437 1564 1614 1693 2442 -42 1306 1447 1575 1627 1707 2460 -40 1315 1457 1585 1630 1720 2479 -38 1324 1468 1597 1643 1733 2497 -36 1333 1478 1609 1655 1746 2516 -34 1342 1488 1621 1667 1758 2534 -32 1351 1499 1632 1678 1771 2552 -30 1360 1509 1643 1689 1783 2571 -28 1369 1519 1654 1701 1795 2589 -26 1378 1529 1665 1713 1807 2608 -24 1387 1539 1676 1724 1819 2627 -22 1396 1550 1688 1735 1831 2645 -20 1405 1560 1699 1746 1843 2664 -18 1414 1570 1710 1757 1855 2683 -16 1423 1580 1722 1768 1868 2711 -14 1432 1590 1733 1780 1881 2730 -12 1441 1601 1744 1792 1893 2748 -10 1449 1611 1755 1804 1905 2757 -8 1458 1621 1767 1815 1918 2776 -6 1467 1631 1778 1827 1930 2795 -4 1476 1641 1789 1839 1943 2813 -2 1484 1651 1800 1850 1955 2832 0 1494 1661 1811 1861 1968 2851 2 1503 1671 1823 1873 1980 2869 4 1511 1682 1833 1885 1993 2888 6 1520 1692 1845 1896 2005 2906 8 1528 1702 1856 1908 2017 2925

10 1538 1712 1867 1920 2030 2943 12 1546 1722 1878 1931 2042 2962 14 1555 1732 1889 1942 2055 2980 16 1563 1742 1901 1954 2067 2999 18 1573 1753 1912 1966 2079 3017 20 1582 1763 1923 1978 2092 3036 22 1590 1773 1934 1989 2104 3055

- 7 -

Settled Temp F 1800 psig 2015 psig 2200 psig 2265 psig 2400 psig 3500 psig

24 1599 1783 1945 2000 2116 3073 26 1608 1793 1956 2013 2129 3092 28 1616 1803 1967 2024 2141 3111 30 1625 1814 1978 2035 2154 3129 32 1634 1824 1990 2046 2166 3148 34 1643 1834 2001 2058 2178 3167 36 1652 1844 2012 2070 2190 3185 38 1660 1854 2023 2082 2203 3204 40 1669 1864 2034 2093 2215 3222 42 1677 1874 2045 2105 2227 3241 44 1686 1884 2056 2116 2240 3260 46 1695 1894 2068 2128 2252 3278 48 1704 1904 2079 2139 2264 3297 50 1713 1914 2090 2150 2276 3316 52 1721 1924 2101 2162 2289 3334 54 1730 1934 2112 2173 2301 3353 56 1739 1944 2123 2185 2313 3371 58 1748 1954 2134 2196 2326 3389 60 1756 1964 2145 2208 2338 3408 62 1765 1975 2156 2219 2350 3426 64 1774 1985 2167 2230 2362 3445 66 1782 1995 2178 2242 2375 3463 68 1791 2005 2189 2253 2387 3482 70 1800 2015 2200 2265 2400 3500 72 1809 2025 2211 2279 2412 3519 74 1817 2035 2222 2288 2424 3537 76 1826 2045 2233 2300 2437 3556 78 1834 2055 2244 2310 2449 3574 80 1843 2065 22556 2322 2461 3598 82 1851 2075 2267 2333 2473 3601 84 1861 2085 2278 2345 2486 3620 86 1869 2095 2289 2357 2498 3639 88 1878 2105 2300 2368 2510 3658 90 1887 2115 2311 2379 2522 3686 92 1896 2125 2322 2390 2534 3705 94 1904 2135 2333 2402 2546 3723 96 1912 2145 2344 2414 2559 3741 98 1921 2154 2355 2425 2571 3760

100 1930 2164 2366 2436 2583 3778

- 8 -

Settled Temp F 1800 psig 2015 psig 2200 psig 2265 psig 2400 psig 3500 psig

102 1939 2174 2377 2448 2595 3796 104 1948 2184 2388 2459 2608 3814 106 1956 2194 2399 2470 2620 3832 108 1964 2204 2410 2482 2631 3850 110 1973 2214 2421 2494 2644 3868 112 1982 2224 2432 2505 2656 3887 114 1991 2234 2443 2516 2669 3905 116 2000 2244 2454 2528 2680 3924 118 2008 2254 2465 2539 2693 3942 120 2017 2263 2476 2550 2705 3961 122 2025 2273 2486 2561 2718 3979 124 2034 2283 2498 2573 2729 3996 126 2043 2293 2509 2584 2741 4014 128 2051 2303 2520 2595 2754 4032 130 2060 2313 2530 2607 2766 4049 132 2069 2323 2541 2618 2778 4067 134 2078 2333 2553 2630 2790 4084 136 2086 2342 2564 2641 2803 4101 138 2094 2352 2574 2652 2814 4119 140 2103 2362 2585 2663 2826 4136 142 2111 2372 2596 2675 2839 4154 144 2120 2381 2608 2686 2851 4172 146 2129 2391 2619 2697 2863 4189 148 2138 2401 2630 2709 2875 4207 150 2147 2411 2641 2720 2887 4224

- 9 -

Table 3

Sources of Reference Documents

DOCUMENT NUMBER TITLE

Federal Specifications

FED-RR-C-901 Cylinders, Compressed Gas: High Pressure, Steel DOT 3AA, and Aluminum Application, General Specification for

FED-STD-313 Material Safety Data, Transportation Safety Data and Disposal Data for Hazardous Material Furnished to Government Activities

Military Specifications

MIL-DTL-2 Detail Specification, Valves, Cylinder, Gas (For Compressed or Liquefied Gases)

MIL-STD-101 Color Code for Pipelines and Compressed Gas Cylinders

MIL-STD-129 Marking for Shipment and Storage

MIL-HDBK-774 Department of Defense Handbook, Palletized Unit Loads

MIL-STD-1411 Standard Practice, Inspection and Maintenance of Compressed Gas Cylinders

Others

Title 29 Occupational Safety and Health Administration Requirements Code of Federal Regulations Chapter XVII

Title 49 Department of Transportation Code of Federal Regulations Hazardous Material Regulations Parts 100 – 199

ASTM F 310 American Society for Testing and Materials, Standard Practice for Sampling Cryogenic Aerospace Fluids

- 10 -

DOCUMENT NUMBER TITLE

CGA G-10.1 Commodity Specification for Nitrogen

Uniform Freight Classification Rules

National Railroad Freight Committee

National Classification Board Rules

National Motor Freight Classification

����$#��,-,./01232���������

��"�����#��4��������� �55�

�� ���� 5��� 6�7�2&-'�

� ��%�+47��#0#01.1'-7�-�������,'33� ��89%+�%�4���#0#01.1'-��,'�:�� ����,''&���7:��%+74#!�4�%���%�7+49�4:����4�+:�%����%7)�47#!������������� �������� ���3����7:9%������ ��<74�=��

��� �������������0

���;��"��������@
�����������

A����"��"���������� A��������"��"������� �������"���

�����������
���
��������7�

�3�� ?�"����>����������7 �

���
����������

� 0� ���,���7!#��4647#�4:������������

���,�3��������������������� �����

���/�B=��� �����4�0��� ������44�0�!�>�����

CDEFGDHIJI�KLDM�NOOPQRREEESJTJLUVPJWSWDM

����������������!����0 1%2�� �� ��3�&�� ����&�������������!����� ���4� ���� ��5������ ��6-��� ���������������!����0 ����������������!����0 1%2�� �� ���(���7���������� ��� ���7�������� ���!��&��8�����%��� ��+�$89�,����:��,9:8+,8�+��� .���8 �� ,�4$9�8

������� ��
������ ��
���4�������(�

��3� �� ��������)�����)�-����'� �� �� ��7=����� (� (�� �)����6 &��� � 1� >�,�� ��.������������������)�*,-��8������ ���2�������)���������)� ��7���

?@ABC@DEFE�GH@I�JKKLMNNAAAOFPFHQRLFSOS@I

������.����������'��/0123��4/5�/062#/0708�9��'-��/���.�������
�������������!!����:���

�����<�/ ��' ;��7� ��79=9 ����79=9�������(��!������������������������� ���<0=�9�=��-�$�>7� ������9�!� ��!���?�@�������7� ��1�.������

�������</ $�-�-�-;��$�>?�@�������������
���>��'���?�@��������������(����4�����

������9�!� /4=2����48<4/7�8�0� /4A#9#489��� -�� �����������������B� ����%���������!��!���������!������� ��� ;��7��B� �����������������B� ��� ; -��7��B�

��������������!������������C��
��D�1#81��C-��

���$����B���$��������B��� �� ���$����B���$��������B����������(����������!�������

���������������&'��C;��
��B���������������������B������������.������

��7#3�9�=�-'-- ��=����

��������EC�$�����(������������������������������

��7#3�9�=�-�- ������������

FGHIJGKLML�NOGP�QRRSTUUHHHVMWMOXYSMZVZGP

���'�����#��"#��01(2-��"#/��&������������������������)����!&+0$#��(�����

�3����&+0������������ �������4���)��������� ����������������)����������������������#��� ����������5�555�5�555� 26�)� ����������������������)���7����������/�/88%��� � ��������7�9 ����������� � � 9

7�/���1� ������� � � 8���1� �$��� � :����7�9;&�����#��������������������������!<=,�<$�� � � �� ����#��>�����������������������!<=,�,$�� � � �� ����#��������������������������� � (���7�/���(����+���:� �� � � 8���(����++���,�������� � �+.���)�����"#8��-����� #��"#8#/���?@�����?�@#�������

�&#1#���6��"/���&���
����� �&���/�8���"��#��2

�)������������������)�����7AA333#�������

#��4A����A#��2

7AA333#�����

�����#��4A���A#��"#8#8��?����� �-��4��� ��-��4��� �-�������������-������ � "��2� ��,B2������& �'��-C �-�����>/�� �C� ������� �.���8� �"#��2

7AA�

A#��"#8#���*� �1�����.� ��4���� ���� ���� �&���/�///���� #��2

7AA�

A#��

DEFGHEIJKJ�LMEN�OPPQRSSFFFTKUKMVWQKXTXEN

�������������/����������������*0�,���������.������1�2�������*-��3�45�-4�3� ��6����73����)�������"��!����������%81����������������������7 �� �����������������/���������������!!����������������������������������������(�����(�!!������������������������!��)�������������������������������)�����/����(�!!���9�������������������������1)��������������!����������+������������!������!1���)������������!����������+����������������������)�������)�������������9���������������������������������� ��!�������������-��������+������0��1�����5�����0��9�� ���"��������/��1���:1�!���)��0��;��!���!������;������������� ���5������)����� ��4�����81�����������������1!����������������!!�(��)������������&��� � ��*0����1������1��������/������������*0�;*3 �4���������������!������)���,����� �;�����1!�����������������)�������81�����,����� �;�����/����������9��)���������9��)���81���������,����6 ���������������1�������������)����1�������)�������7:7������1!9�!�81��������)���,����6 �;�!!���+��������81���������,����6 ���*��������1�� ��5�!���!�����������)���)�����!��������������������1��������1�)����������1��+���<�)���������������1����������������������� ��*�����!!���!�����1����(������!����������)�������������������������������!���������������������������������!�9�������1���)�������������1�� �����������������������<�)����������(���������!���!������)�����1!�����1!����������������<�!������(����!�������!�������!�������������!����(������������� ��4�����*0���������1����!����������1���������������)�������1���������������!������������!���������������������!�������� 6��$�!/���1�!�������������� �����1������������ ��4���/�!/���1�!��������������������!���!�����������)������1!����������������������!������/�!/���1�!���������������������/���������������1��1��������!���!�����������)�����!�������������!���������!�������� ������/������!�(�������!!�����1����1���)������!���!����������������,�����1��+��)���!����������)����������� �������������1��.

����������1!�����!������������������������(������!���������������1����������!���������!�������� ��4������!����!���������������/�!/������������������ ��$����7-����������������������� �����!������$�!/��51�!�������*�!��������������7 ��3���������/�!/����������������������!�������������������������)�������� ��4���������������!������������!��**����!�

=>?@A>BCDC�EF>G�HIIJKLL???MDNDFOPJDQMQ>G

����������������������������������������� !��"#� $!�����%���� �%��&����%����������&� ����'���#� �(�� (��������)� ������������#� ���� )&��*�*��+��,��������� -�.�/��0#�������"���� �������1�������2��"��3."���� ����������� ���!�����0�"���� ������"��"����� ��.�"������ �.���0���� ������� 4���'����� 4������������� ��������5��� ���"��� +�����%�������'��� ���������� �6��� �78��9

9�8��447<�9� �9;��� 8:� �����0����:� � ;+����=�+�� �����.��������9��.���+>�������=������� (���<�����;+� � �� � � �� 7����/�����������:������.����7%�6<&���9��.����+%�6�%�4+%�8<���4�2�����<+� � ���!����"��������.:�<�����;+��� ���,���� (���)�&&����#���94

2������������������0�������/�������������0�����2���0������������'��2��0�����'��2���0����������+�������"���5���������0����!������������������2��"�%�.����2���0�����'.��2���������.��'��2����'�������������������"��2���++�+ �0�����������2��!�:??�������0�!��0������?��

@ABCDAEFGF�HIAJ�KLLMNOOBBBPGQGIRSMGTPTAJ

File details come from the government source that posted it. Updated .