Mechanical Record Set - VA Med Surge 42.pdf
PDF 471 KB Posted
- Attached to
- J041--Chiller & Condenser Maintenance - SF Federal contract opportunity
- Solicitation number
- 36C26324Q0595
About this file
This document is a mechanical record drawing set for the VA Medical Surge 42 project. It provides detailed schematics and layouts for the HVAC system, including the placement of air handlers, exhaust fans, ductwork, and piping. The drawings indicate the size, type, and specifications of the mechanical equipment. General notes outline installation requirements, coordination with other trades, and guidelines for the contractor. This drawing set is intended to be used as a record of the completed construction, rather than design documents.
The related federal contract opportunity is for HVAC chiller and condenser maintenance services at the Sioux Falls VA Health Care System. This is a combined synopsis/solicitation for commercial items, issued as a request for quotes (RFQ) under a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside. The period of performance is one base year with four one-year option periods. Quotes are due by April 19, 2024 at 4:00 PM Central Time and should be emailed to the Contracting Office.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation 36C26324Q0595 Amendment 0001.pdf | ||
| 36C26324Q0595 0001_1.docx | DOCX document | |
| Mechanical Record Set - VA Med Surge 35.pdf | ||
| Mechanical Record Set - VA Med Surge 32.pdf | ||
| Mechanical Record Set - VA Med Surge 18.pdf | ||
| Solicitation 36C26324Q0595.pdf | ||
| 36C26324Q0595_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
DN
RECORD DRAWING
DATE: BY:
THE ISSUANCE OF THIS RECORD DRAWING IS A
REPRESENTATION BY THE ARCHITECT/ENGINEER THAT
THE CONSTRUCTION OR ALTERATIONS OF THE BUILDING
IS IN GENERAL, AS OPPOSED TO PRECISE, CONFORMITY
WITH THE DESIGN PREPARED AND PROVIDED BY THE
ARCHITECT/ENGINEER.
1S 2S 3S 4S
2.9
E36E32 E33 E34 E35
5-AHU9
5-ERC5
38"x32"
"x
28"x40"
"x
42"x14"
42"x16"
42"x16"
72"x44"
"x
18"x10"
36"x40"5-EF11
5-UH3
42X14, 42X16, 42X16 EA
DUCTWORK DN THRU
FLOOR
24X36 SA DN
THRU FLOOR
5-PH37
5-AHU36
30"x30"
42"x28"
30"x28"
5-PHR-37
5-PHR-36
5-RF-36
5-RF-37
5-AHU-37
5-PGH36
5-PGH37
G H
R G
H S
5-PC37
5-PC36
5-CH-36
36"x20"
"x
CWS
CWR
4" 4"
3" 3"
HUMIDIFIER
HUMIDIFIER
2"
DROP
2" 2"
HWS
HWRRISE
RISEDROP
DROP
RISE
DROP RISE
2"
2"2" 2"
2"
2"
6" 6"
2 1/2" 2 1/2"
FD-F
FD-F
FD-F
FD-F
1C
5-MH505
1F
5-MH505
MPR
MPS
CWR
CWS
G H
R
G H
S
C W
S
C W
R
M P
S
3/4"
1 1/4"
M P
R
MPR
NEW 5" MPS DN.
NEW 1 1/2" MPR DN.
5" 30# MPS
M P
S M
P R
1/
2"
3/4" F/T
M P
R
MPS
2 1/2" 30# MPS
MPS
1 1/2" 1 1/2"
1/
4"
1/ 4"
M P
R
MPR
3/4"
3/4"
5-HX1, 5-HX2 STACKED (SEE DETAIL)
5-HX3, 5-HX4 STACKED (SEE DETAIL)
2"
3" 3"
H W
S
4"
4" 4"
5-ET15-ET2
H W
R
4"
1/
2"
5-AS2
2 1/2" LPR DN. IN CHASE
3/ 4"
M P
R
6" STEAM V.
UP THRU ROOF
1 1/2" MPS TO
HUMIDIFIER
1 1/2" MPS
TO HUMIDIFIER
1 1/4"
4"
GHS
4"
GHR
1 1/2"
GHR
GHR
1 1/2"
3"
G H
S
4"
GHS
3"
GHS
1 1/2"
3" 4"
CWR
6"
CWS
6"
6"
4"
C W
R
6"
6"
5-AS3
3" 3"
5-ET3
4"4"
CWS
CWR
6" 6"
1 1/2"
1 1/2"
3/4" MAKEUP
WATER
3/4" MAKEUP
WATER
3/4" MAKEUP
WATER
1S
2.9
2S 3S 4S
5-HRC-36E
5-HRC-37E5-HRC-36S
5-HRC-37E
"x
"x
111"x24"
108"x54"
36"x24"
18"x10"
"x
"x
10"x18"
"x
36"x20"
30"x48"
30"x48"
144"x28"
"x
"x
62"x29"
"x
62"x28"
28"x62"
"x
"x
"x
62"x28"
"x
28"x62"
"x
62"x28"
"x
"x
90"x26"
"x
96"x24"
"x
"x
"x
"x
42"x32"
"x
"x
"ø
"ø
"ø
"x
"ø
20"x36"
"x
18"x12"
EXISTING
4" DOWN TO 5-HX-2
1" LPR DOWN TO 5-HX-1 AND 5-HX-2
1 1/2" LPR DOWN TO 5-HX-3 AND
5-HX-4
M P
S
1/
2"
3/4" F&T
LPR
3/4" MPR
SEE DETAIL FOR CV
ASSEMBLY (1/3-2/3 CVS)
5-PHR-38
G H
S G
H S
G H
R
4"
"x
"x
C W
S
C1
5-MH506
F1
5-MH506
EXIST.
6'-0"x5'-0" EA
LOUVER - L-
09R
4'-0"x6'-0" RELIEF
AIR LOUVER - L-36R
4'-0"x6'-0" RELIEF
AIR LOUVER - L-
37R
NEW 3'-6"x2'-8"
RELIEF AIR LOUVER -
L-10R
CEMLINE V25CCP-3x2-D-65
STEAM CONDENSATE
RECEIVER TANK, NON-ELECTRIC
CONDENSATE PUMPS
F5
5-MH506
"x
"x
RCP-12
FD-F
PRV-1
6" HEADER
RCP-13
30 PSI TO 5 PSI
PRV, 3,432 LB/HR.
5-AS1
LPR
3/4"
1"
4"
3/ 4"
F&T
LPR
3/4"
SEE DETAIL FOR CV
ASSEMBLY (1/3-2/3 CVS)
NOTE: NOT ALL KEYNOTES MAY BE USED ON EACH PLAN
MECHANICAL ENLARGED KEYNOTES
1 3" GHWS & CHWR UP TO SECOND FLOOR.
2 4" HWS & HWR UP IN CHASE.
3 4" CWS & CWR UP IN CHASE.
2 1/8" REFRIGERANT LINES FROM CHILLER 5-CH-36 UP TO CONDENSERS ON
ROOF.
ROUTE 1" DRAIN PIPE DOWN TO NEAREST FLOOR DRAIN. ROUTE PIPING TO
CROSS FLOOR NEAR EXISTING PIPING. PITCH TO FLOOR DRAIN.
6 2" FEMALE PIPE COUPLING FOR PLENUM DRAIN CONNECTION.
THERE ARE SOME CHANGES THAT WERE DONE IN THE FIELD IN THIS AREA
THAT WE DO NOT HAVE DOCUMENTATION ON THE CHANGES. FIELD VERIFY
TO SEE THESE CHANGES.
8 -
9 -
10 -
KEYPLAN
N O
R T
H
BUILDING
REMODE
L
BUILDING
ADDITION EXISTING
BUILDING
1. MATERIALS AND EQUIPMENT SHOWN ON PLANS SHALL BE NEW AND SHALL BE
FURNISHED BY THIS CONTRACTOR UNLESS OTHERWISE INDICATED.
2. IN GENERAL, DUCTWORK SHALL BE RUN CONCEALED IN SUSPENDED CEILING
SPACES AND IN SHAFTS PROVIDED UNLESS NOTED OR OTHERWISE
INDICATED. CERTAIN ROOMS HAVE NO SUSPENDED CEILINGS, AND
DUCTWORK IN THESE ROOMS SHALL BE EXPOSED.
3. DUCTWORK IS INTENDED TO BE CONCEALED IN WALLS AND PARTITIONS
UNLESS SPECIFICALLY NOTED OTHERWISE. SOME ITEMS MAY APPEAR NOT
TO BE CONCEALED DUE TO DIGITAL REGISTRATION AND ALIGNMENT ISSUES
ASSOCIATED WITH THE DUPLICATION PROCESS.
4. COOPERATE WITH THE OTHER TRADES TO AVOID ANY CONFLICTS BETWEEN
PIPING, DUCTWORK, ELECTRICAL WORK.
5. DETAILS, SCHEMATICS, DIAGRAMS, DESIGNATE GENERAL ARRANGEMENT
ONLY.
6. FOR DETAILS, EQUIPMENT CONNECTIONS, AND PIPE SIZES NOT SHOWN ON
FLOOR PLANS, REFER TO ELEVATIONS, DETAILS, RISERS AND SCHEDULES.
7. THIS CONTRACTOR IS RESPONSIBLE FOR ALL SLEEVES AND/OR OPENINGS
WHERE REQUIRED TO RUN PIPES AND DUCTS THROUGH FOUNDATIONS,
FLOOR SLABS, WALLS, BRIDGING AND BEAMS EXCEPT WHERE OTHERWISE
INDICATED.
8. CONSULT REFLECTED CEILING PLAN FOR EXACT LOCATION OF SPRINKLER
HEADS, GRILLES, REGISTERS, AND DIFFUSERS.
9. CEILING ACCESS IS REQUIRED AT ALL REHEAT COILS, VALVES, FIRE
DAMPERS, MANUAL AND MOTORIZED DAMPERS LOCATED ABOVE CEILING.
CEILING ACCESS PANELS WILL BE PROVIDED UNDER THE GENERAL SECTION
OF CONSTRUCTION AND SHALL BE MINIMUM OF 24" X 24" UNLESS
OTHERWISE INDICATED. COORDINATE WITH GENERAL CONTRACTOR.
10. THERMOSTATS LOCATED AT OUTSIDE WALLS SHALL BE MOUNTED ON
INSULATED BACKING TO MINIMIZE WALL EFFECT.
11. THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING
CONDITIONS AND DIMENSIONS. NOTIFY THE A/E IMMEDIATELY OF ANY
DISCREPANCIES.
12. WHERE NEW SERVICES ARE SHOWN CONNECTING TO EXISTING, VERIFY
EXACT LOCATION AND SIZE OF EXISTING.
13. EXISTING SERVICES SHALL BE MAINTAINED UNLESS OTHERWISE INDICATED.
14. ALL DUCTS WHICH ARE DASHED AND/OR INDICATED BY NOTE ON DEMOLITION
PLANS SHALL BE REMOVED.
15. DIFFUSERS IN ROOMS WITHOUT FINISHED CEILINGS SHALL BE INSTALLED
WITH THE BOTTOM OF THE DIFFUSER AT 9'-0" ABOVE FINISHED FLOOR
UNLESS OTHERWISE INDICATED.
16. VERIFY DUCT CONNECTIONS SIZES TO POWER ROOF VENTILATORS.
17. WHERE SHEET METAL HOUSING, PLENUMS AND DUCTWORK ARE FASTENED
TO GENERAL CONSTRUCTION. TAKE SPECIAL CARE TO MAKE AN AIRTIGHT
SEAL AT THIS POINT.
18. DUCTWORK AND CONNECTIONS BETWEEN THE 4-INCH PRESSURE
DUCTWORK AND THE VAV BOXES SHALL BE THE SIZE OF THE BOX INLET.
DO NOT USED FLEXIBLE DUCTWORK.
19. FLEXIBLE DUCTWORK AND CONNECTIONS BETWEEN THE LOW PRESSURE
DUCTWORK AND THE DIFFUSERS SHALL BE THE SIZE OF THE DIFFUSER INLET.
CONNECTION TO THE 2-INCH DUCT SHALL BE MADE THROUGH A CONNECTOR
DAMPER ASSEMBLY.
20. FOR FLEXIBLE DUCTWORK CONNECTIONS, NYLON DUCT STRAPS SHALL BE
USED. USE A DUCT STRAP ON INNER DUCT AND ON OUTER INSULATION
COVERING.
21. BUTTER AND SEAL ALL SHEET METAL DUCTWORK JOINTS.
22. WHERE MATERIAL IS INDICATED TO BE REMOVED, IT SHALL REMAIN THE
PROPERTY OF THE OWNER. THIS CONTRACTOR SHALL DISPOSE OF
MATERIAL AS DIRECTED BY THE OWNER.
23. BALANCING OF AIR AND HYDRONIC SYSTEMS SHALL BE PERFORMED BY AN
NEBB OR AABC CERTIFIED TEST AND BALANCE AGENCY.
24. DUCT PENETRATIONS OF SMOKE PARTITION WALLS SHALL BE PROPERLY
SEALED TO RESIST THE PASSAGE OF SMOKE AS REQUIRED BY THE LOCAL
AUTHORITY.
25. MECHANICAL CONTRACTOR SHALL PROVIDE BALANCING DAMPERS WHERE
INDICATED. IN ADDITION CONTRACTOR SHALL PROVIDE BALANCING DAMPERS
ON DUCT TAKE-OFFS TO DIFFUSERS, GRILLES, AND REGISTERS, REGARDLESS
OF WHETHER DAMPERS ARE SPECIFIED AS PART OF THE DIFFUSER, GRILLE,
OR REGISTER ASSEMBLY. THE BALANCING DAMPER SHALL BE LOCATED IN
THE DUCT IMMEDIATELY AFTER THE DUCT TAKE-OFF AT THE MAIN DUCT
CONNECTION.
26. SEE SPECIFICATIONS FOR DUCT INSULATION AND DUCT LINER
REQUIREMENTS.
27. SEE SHEET 5-MH401 ENLARGED FIRST FLOOR MECHANICAL ROOM PLAN FOR
ADDITIONAL INFORMATION.
28. PROVIDE TURNING VANES FOR ALL MITERED ELBOWS.
HVAC PLAN GENERAL NOTES
10/19/2018
Copyright TSP, Inc. 2012
CONSULTANTS:
Drawing Number
Drawing Title
A
TSP, Inc.
1112 N. West Ave, Sioux Falls, SD 57104 phone: (605) 336-1160 fax: (605) 336-7926 www.teamtsp.com Date Checked Drawn
Project Number
Building Number
Project Title
Location
ARCHITECTS/ ENGINEERS:
Approved: Project Director
Office of Construction and Facilities Management
Dwg. of
Department of Veterans Affairs
C
D
E
F
B
A
C
D
E
B
F
2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
VA FORM 08-6231
FULLY
SPRINKLERED
/1
9/
:0 2:
P
M
I:\ _T
S P
R ev it Lo ca l\0
7_
V A
_M ed
S ur g_ M
E P
_q ua m en kj
.r vt
ENLARGED 1ST FLOOR MECHANICAL ROOM
PLAN
5-MH401
100% CONSTRUCTION DOCUMENTS
VA Medical Center 2501 W. 22nd Street, PO Box 5046 Sioux Falls, SD 57117-5046
Acute Inpatient Med. Unit Add & Renovation
Sioux Falls VA Health Care System
JTC08/06/2012 BSW
04100857
92 123
1/4" = 1'-0"1F
ENLARGED 1ST FLOOR MECHANICAL ROOM PLAN
MARK REVISION DESCRIPTION DATE
PR18 PR18 04/04/2016
R Record Drawings 07/27/2018
RDND Record Drawings - No Documentation Changes 07/27/2018
KJQ
RDND
File details come from the government source that posted it. Updated .