Mathers Control Drawings.pdf
PDF 1 MB Posted
- Solicitation number
- 1305M222QNMAN0068
View the file
Other files
Show 40 more
Latest 50 of 73 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PILOTHOUSE CONTROL STATION ,JiJ i ~~~~~~~l B B B E9:E9:
\.1/ J®J® @ - \j
I ITEHS WITHIN OASHEO LINES 'j I ARE USER SUPPLlEO I t, ATII PANEL
12.3 x 15.5 x 5 (312 x 394 x 127mm)
AIR SUPPLY
150-250 PSI
( 10.6-17 .6KGlCH2)
~RAKE SUPPLY 65 PSI
FlJlL~OLE~ - - - --
\ 0 • 5 II 4 3 8 156 I 2
<0 SPEED
AUXILIARY is'
GOVERNOR \.V'-- ,AI
POSIT IDNER '¥dI ASTERN
<0 AHEAD
<0 CLUTCH
9 7 12 10
CH5 PORT NUMBERS
I SUPPLY
6 SPEED
7 ASTERN
8 AHEAD
ADI2 CONTROL
9.5 x 18.5 x 7 (241 x 470 x 178 mm)
PORT NUMBERS
I SUPPLY
2 AH:AD
3 ASTERN
4 PLUG-NOT USED
5 SPEED-OUT
6 SPEED-IN
7 ASTERN
8 AHEAD
5\1438156
<0 SPEED
<0 ASTERN'
<0 AHEAD
<0 BRAKE
9 13 12
MS526 CIRCUIT BOXES
16 x 20 x 3.5 (406 x 508 x 241mm)
B) BLOW OOWN ALL AIR LINES TO INSURE THEY. ARE FREE OF
DEBRIS BEFORE MAKING FINAL CONNECTIONS
@:> ATII PANEL REGULATOR( S) TO BE ADJUSTED AND SEALED IN
POSITION DURING SEA TRIALS
@::> THESE ITEMS MUST BE INSTALLEO WITHIN 25 FEET (8 METERS)
OF THE REDUCTION GEARS
@:> AIR LINES ON CLUTCH ACTUATOR CAN BE REVERSEO PER
OPERA TlONAL REOUIREMENTS
It> AIR LINES CONNECTING CIRCUIT BOXES WITH PNEUMATIC
CLUTCHES MUST BE NO LONGER THAN 10 FEET (3 HETERS)
@:>- BRAKE SYSTEM MUST BE FILLED WITH 10 WT. ENGINE OIL
DR MINERAl. BASED HYDRAULIC OIL
B:> MAXIHlJo4 HYDRAULIC PRESSURE NOT TO EXCEED 1800 PSI
- TUBING KEY -
1/4' (6-7 •• ) 0.0. TUBING (.025 ~ALLl ======= 112' 112-130.) 0.0. TUBING <'035 ~AlL> ------- 518' (15-16mm) 0.0. TUBING (.040 VALL>
HOVED POSITION OF CHECK VALVE
G 0-9 At() ADDED USER SUPPLIED ITEMS
SHOWN IN DASHED AREA.
F 9-95 ADDED ITEM 39 (CHECK VALVE)
E 8-91 ITEM 3D-PORT 'AI' WAS '81'
PORT 'A2' WAS 'B2'
ITEM 21-PORT 'AI' WAS 'BI'
'P.H.' WAS 'REMOTE'
o 7-91 AOOOOITEHS 24-3 At() 24-, ADDED ITEHS 36-1 AND 36-2
NUHEERED PORT 1 ON ITEMS 24-1
AND 24-2
ADDED PORT 5 COt-.NECTIONS
.' TO ITEHS 5 AND 6
SEE SlUT 2
C 6-91 ITEM 24-1. PORT' 3 (WAS) I
B 4-91 REVERSED EXHAUST ~ SUPPLY
PORTS ON ITEM 24-2
A 4-91 ADDED ITEMS \9 TfJlU 35
REV BY OATE DESCRIPTION
MATHERS CONTROLS INC.
675 PEASE ROAO BURLINGTON WA. 98233
TWO STATION REMOTE PNEUMATIC CONTROL
SYSTEM W/CDMPOUND GINES
ENG. OWN. SCENARO
CKD. u DATE 2-7-90
SCALE: NONE SHT. I OF 2
- TUBING KEY -
----------------------1/4" (6-7nn) 0,0, TUBING -------------------- 3/8" (9- 1Or1M) 0, 0, TUSI NG
-------------------- 112" (12-13nn) 0,0, TUBING
VJ
Z -.J >- Q r::J<: f-- 0 -.J =:J U r::J<: Q 0 f-- W f-- CL W W -.J Z :::J W r::J<: W 0 VJ Q
VJ U VJ
U U 0 Z Z 0 Z > t-< > t-i l\J ::>:: ::>:: l\J ::>::
I CLUTCH SUPPLY
2 AHEAD -IN
3 ASTERN -IN
4 SPEED-IN
5 LOCAL SELECT
6 SPEED-OUT
8 MAIN ENGINE 'OUT' ~9 BRAKE 10
11 BRAKE SUPPLY
12 AHEAD CLUTCH
13 ASTERN CLUTCH
15 AUXILIARY ENGINE' IN'
3Sr-:=
FAL~~
~ ~SET POINTV 0 ,40-60 PSI
NOTE: SEE COMPUTER GENERATED
LIST OF MATERIAL
A 7/91 ADDED PORT 5 CONNECTION
TO CIRCUIT BOX
REV BY DATE DESCRIPTION
MATHERS CONTROLS INC,
902 NW BALLARD WAY SEA TTLE WA 98107
MS526 CIRCUIT BOX
REFERENCE DRAWING
ENG, SHT, 1 OF 1 DATE: 2-22-90
OWN, SCENARD SCALE: NONE
PART NO, MS526-08000 DWG,NO, 7621-A