803-3275003-10 TJ HVAC Upgrade Engineering Data Package.pdf

PDF 3 MB Posted

Attached to
Drawings/References for the THOMAS JEFFERSON Dockside Repairs FY23
Solicitation number
1305M222QNMAN0068
Issued by

View the file

Other files

File Type Posted
SNAME Technical and Research Bulletin 4-16_Calculations for Merchant Ship HVAC Design (2015).pdf PDF
NOAA Thomas Jefferson Ships Registry TTS.pdf PDF
NOAA Thomas Jefferson Procedure 1701-09 TJ - Hot Work Operations.pdf PDF
TJ_FY23_DS_Gauge Meter Inventory (Updated 20220601).pdf PDF
MOC-573-2 Overhaul Repair of Hydraulic Cylinders.pdf PDF
Register of Lifting Appliances_fillable.pdf PDF
NAVSEA Standard Item 009-32_Cleaning and Painting Requirements.pdf PDF
Calculations for Merchant Ship HVAC Design (2015).pdf PDF
320-6634679_E Cableway Arrangement and Details - AS BUILT(1).pdf PDF
Document locations.pdf PDF
TJ-152-002B Deck Extension Structure _ Grating Replacement_131148294.pdf PDF
301-001_C_Electrical One Line Dia - AS BUILT.pdf PDF
ABS Marine Vessel Rules.pdf PDF
Appendix I to Part 1918_ Title 29 (up to date as of 6-21-2022).pdf PDF
TJ_FY23_DS_MCT P2 Repairs.xlsx XLSX spreadsheet
512-6634850F HVAC Arrangement and Details Engine Room_130758174.pdf PDF
NOAA Form 57-17-09 - Hot Work Permit.pdf PDF
Weight Reporting Spreadsheet.docx DOCX document
NOAA Standard Specifications MOC-300-3_General Requirements for Electrical_Electronic Items.pdf PDF
624-6634931 Joiner Door Schedule.pdf PDF
512-3275003-8 HVAC MODS MN DECK REV B.pdf PDF
TJ-233-03 EMD Engine_Maintenance Instruction_1722 Rev I.pdf PDF
085-6980295E TJ Tank Capacities _ Soundings.pdf PDF
TJ-233-01 Detroit Diesel 6V92.pdf PDF
321-3274004-3A HVAC Elec Control Mods Incdt HVAC Mods.pdf PDF
505-6634825 Standard Piping Details.pdf PDF
321-3274004-2A HVAC Electrical Pwr Mods Incdt HVAC Mods.pdf PDF
NOAA StandardSpecification AMC-505-2_Hydrostatic Pressure Tests.pdf PDF
NOAA Standard Specification AMC-300-1 Overhaul of Electrical Rotating Machinery.pdf PDF
514-3275003-12 Rev A AC PP INSTALL FCSLE DK _ ABV.pdf PDF
514-3275003-6 REV A AC PIPING INSTL 2ND DK _ BLW.pdf PDF
TJ-241-01 Reduction Gear Main Propulstion RS2719S.pdf PDF
512-004_-_HVAC Makeup Air Modifications.pdf PDF
TJ-436-01A - Consilium Salwico CS4000 Operations Manual.pdf PDF
TJ-233-03 EMD Engine 12-645F7B.pdf PDF
985-6634639 REV N Fire Control Plan Final_123787221_123332124.pdf PDF
085-002H Booklet of General Plans.pdf PDF
Mathers Control Drawings.pdf PDF
514-003_-_Refrigerant System and Condensate Piping Modifications.pdf PDF
NOAA Standard Specification AMC-635-2 Thermal Insulation for Compartments.pdf PDF
NF 57-17-09 - Hot Work Permit.pdf PDF
NOAA Standard Specification 000-1H General Requirements for Ship Repair Contract Work.pdf PDF
501-6634837C Reach Rod ARR _ Details.pdf PDF
101-6634906 Structural standards.pdf PDF
NOAA Standard Specification MOC-635-1 Thermal Insulation for Piping.pdf PDF
320-6634679_E Cableway Arrangement and Details - AS BUILT.pdf PDF
514-3275003-11 REV A AC PIPING INSTL MN DK.pdf PDF
NOAA General Technical Requirements (GTR) Rev -.pdf PDF
525-6634754F Fill Vents and Sounds Arrangement _ Details.pdf PDF
TJ-651-02 Grease interceptor Gaylord Hood.pdf PDF
Show 40 more

Latest 50 of 73 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Thomas Jefferson HVAC Upgrade

Engineering Data Package

70 Fargo Street

Boston, Massachusetts 02210 Date: March 25, 2015

Table of Contents

HVAC Calculations ‐ Heating/Cooling

SW Cooling System Piping Calculations

Chilled Water/Jacket Water Piping System Calculations

SW Cooling & Chilled Water Reference Material

NOAA THOMAS JEFFERSON

HVAC ENGINEERING DATA PACKAGE

Reference:

1. HVAC Load Calculations, 514‐6634840

Notes:

1. All compartment sensible and total room loads are taken from reference (1).

2. Replenishment Air load per CFM is taken from reference (1).

Abbreviations:

Hs – Room Sensible Load Ht – Room Total Load Hw – Room Heating Load REPLSN Air – Replenishment Air Quantity Hras – Replenishment Air Sensible Load Htra – Replenishment Air Total Load Hrat – Room Sensible Load with Replenishment Air Hrms – Room Total Load with Replenishment Load

Compartment Sizing Information

1. Pilot House (03‐27‐0)

Hs Ht Hw REPLSN Air

Hras Htra Hrat Hrms System Number

45655 46735 15657 55 2640 5995 48295 52730 1

Use 3 size PLFY‐P15NCMU‐ER4 and 1 size PLFY‐P08NCMU‐ER4 Total Capacity: 53000 BTU’s

2. Radio Room (03‐33‐2) Hs Ht Hw REPLSN

Air Hras Htra Hrat Hrms System

Number 15000 15360 1900 55 2640 5995 17640 21355 1

Use 2 size PLFY‐P12NCMU‐ER4 Total Capacity: 24000 BTU’s

3. Chart Room (03‐36‐0)

Air Hras Htra Hrat Hrms System

Number 7547 8267 4547 55 2640 5995 15888 19963 1

Use 1 size PLFY‐P24NBMU‐ER2

4. Aft Radio Room (03‐39‐2)

Air Hras Htra Hrat Hrms System

Number 1934 2294 1569 55 2640 5995 15547 19262 1

Use 2 size PLFY‐P12NCMU‐ER4

5. Captain’s Office (02‐24‐1)

Air Hras Htra Hrat Hrms System

Number 9741 11286 5860 30 1440 3270 11181 14556 1

Use 1 size PLFY‐P15NCMU‐ER4 Total Capacity: 15000 BTU’s

6. XO Office (02‐24‐2)

Air Hras Htra Hrat Hrms System

Number 8797 10342 5311 35 1680 3815 10477 14157 1

7. XO Stateroom (02‐31‐2)

Air Hras Htra Hrat Hrms System

Number 6275 6635 3916 45 2160 4905 8435 11540 1

Use 1 size PLFY‐P12NCMU‐ER4 Total Capacity: 12000 BTU’s

8. CO Stateroom (02‐37‐3)

Air Hras Htra Hrat Hrms System

Number 6275 6635 3916 45 2160 4905 8435 11540 1

9. Stateroom (02‐40‐2)

Air Hras Htra Hrat Hrms System

Number 6275 6635 3916 45 2160 4905 8435 11540 1

10. CHENG Office (01‐19‐1)

Air Hras Htra Hrat Hrms System

Number 7241 8786 4873 55 2640 5995 9881 14781 2

11. Operations Officers Office (01‐19‐2)

Air Hras Htra Hrat Hrms System

Number 7549 9094 4975 50 2400 5450 9949 14544 2

12. CHENG Stateroom (01‐25‐1)

Air Hras Htra Hrat Hrms System

Number 3118 3478 1483 55 2640 5995 5758 9473 2

13. Operations Officers Stateroom (01‐23‐2)

Air Hras Htra Hrat Hrms System

Number 5719 6079 3190 50 2400 5450 8119 11529 2

14. 1ST Asst Engineer Stateroom (01‐29‐2)

Air Hras Htra Hrat Hrms System

Number 3036 3396 2208 55 2640 5995 5676 9391 2

15. Stateroom (01‐34‐1)

Air Hras Htra Hrat Hrms System

3416 3776 1554 55 2640 5995 6056 9771 1

16. Stateroom (01‐34‐4)

Air Hras Htra Hrat Hrms System

3145 4225 1414 55 2640 5995 5785 10220 1

17. Stateroom (01‐39‐1)

Air Hras Htra Hrat Hrms System

3716 4076 2207 55 2640 5995 6356 10071 1

18. Stateroom (01‐39‐2)

Air Hras Htra Hrat Hrms System

2353 2713 1301 55 2640 5995 4993 8708 1

19. Stateroom (01‐43‐4)

Air Hras Htra Hrat Hrms System

4204 4564 3385 55 2640 5995 6844 10559 1

20. GSM Stores (1‐8‐1)

Air Hras Htra Hrat Hrms System

17681 19451 12298 75 1950 6375 19631 25826 2

Use 1 size PLFY‐P15NCMU‐ER4 and 1 size PLFY‐P12NCMU‐ER4 Total Capacity: 27000 BTU’s

21. Passage (1‐8‐0)

Air Hras Htra Hrat Hrms System

75 1950 6375 1950 6375 2

Use 1 size PLFY‐P08NCMU‐ER4 Total Capacity: 8000 BTU’s

22. Mess Deck (1‐16‐1)

Air Hras Htra Hrat Hrms System

16723 25723 5515 380 18240 41420 34963 67143 2

Use 2 size PLFY‐P36NBMU‐ER2 Total Capacity: 72000 BTU’s

23. Chief Steward’s Office (1‐25‐4)

Air Hras Htra Hrat Hrms System

2816 3846 1299 75 1950 6375 4766 10221 2

24. Dry Stores (1‐25‐2)

Air Hras Htra Hrat Hrms System

2816 3846 1299 30 1440 3270 4256 7116 2

25. SSFC/UPS Space (1‐32‐2)

Air Hras Htra Hrat Hrms System

2583 3463 375 75 1950 6375 4533 9838 4

Use 1 size PKFY‐P12NHMU‐E2

26. Lounge (1‐30‐1)

Air Hras Htra Hrat Hrms System

8304 11904 2560 75 1950 6375 10254 18279 2

Use 1 size PLFY‐P12NCMU‐ER4 and 1 size PLFY‐P08NCMU‐ER4 Total Capacity: 20000 BTU’s

27. Plot Room (1‐32‐4)

Air Hras Htra Hrat Hrms System

82615 85255 6604 300 9300 25200 91915 110455 4

Use 4 size PLFY‐P15NCMU‐ER4, 1 size PLFY‐P24NBMU‐ER2 and 1 size PKFY‐P30NHMU‐ER2 Total Capacity: 114000 BTU’s

28. Hospital (1‐42‐1)

Air Hras Htra Hrat Hrms System

6804 7884 4147 75 1950 6375 8754 14259 2

29. Ship’s Storage (2‐8‐2)

Air Hras Htra Hrat Hrms System

641 1821 128 60 2880 6540 3521 8361 3

30. GSM Stores (2‐8‐1)

Air Hras Htra Hrat Hrms System

7684 9154 10020 50 2400 5450 10084 14604 3

31. Scientific Stores (2‐22‐3)

Air Hras Htra Hrat Hrms System

60 2880 6540 2880 6540 3

Note: The compartment heat load calculations for this space are included in Scientific Stores (2‐22‐2)

32. Scientific Stores (2‐22‐2)

Air Hras Htra Hrat Hrms System

19473 21018 11712 55 2640 5995 22113 27013 3

Use 2 size PLFY‐P15NCMU‐ER4 Total Capacity: 30000 BTU’s

33. Stateroom (2‐25‐2)

Air Hras Htra Hrat Hrms System

2965 3685 1113 60 2880 6540 5845 10225 3

34. Stateroom (2‐30‐1)

Air Hras Htra Hrat Hrms System

2818 3538 2637 60 2880 6540 5698 7078 3

35. Stateroom (2‐34‐1)

Air Hras Htra Hrat Hrms System

7243 7963 3260 60 2880 6540 10123 14503 3

36. Stateroom (2‐34‐2)

Air Hras Htra Hrat Hrms System

5750 6470 2882 60 2880 6540 8630 13010 3

37. Stateroom (2‐39‐1)

Air Hras Htra Hrat Hrms System

6096 6816 2635 60 2880 6540 8976 13356 3

38. Stateroom (2‐39‐2)

Air Hras Htra Hrat Hrms System

4703 5423 2275 60 2880 6540 7583 11963 3

39. Stateroom (2‐43‐1)

Air Hras Htra Hrat Hrms System

6193 6913 2635 60 2880 6540 9073 13453 3

40. Stateroom (2‐43‐2)

Air Hras Htra Hrat Hrms System

41. Stateroom (2‐47‐1)

Air Hras Htra Hrat Hrms System

6594 7314 3258 60 2880 6540 9474 13854 3

42. Stateroom (2‐47‐2)

Air Hras Htra Hrat Hrms System

43. Stateroom (2‐51‐1)

Air Hras Htra Hrat Hrms System

8677 9397 4561 50 2400 5450 11077 14847 3

44. Stateroom (2‐51‐2)

Air Hras Htra Hrat Hrms System

8063 8783 4355 50 2400 5450 10463 14233 3

45. MCS (2‐63‐1)

Air Hras Htra Hrat Hrms System

52043 54618 9510 125 6000 13625 58043 68243 4

Use 1 size PKFY‐P30NKMU‐E2, 1 size PLFY‐P15NCMU‐ER4 and 2 size PLFY‐P12NCMU‐ER4 Total Capacity: 69000 BTU’s

46. Exercise Room (3‐22‐0)

Air Hras Htra Hrat Hrms System

9899 12474 10932 75 3600 8175 13499 20649 3

Use 1 size PLFY‐P24NBMU‐ER3

47. Dive locker (1‐77‐0)

Air Hras Htra Hrat Hrms System

25772 27042 5149 55 2640 5995 28412 33037 4

Use 1 size PLFY‐P36NBMU‐ER2 Total Capacity: 36000 BTU’s

System Capacity System 1

Compartment Total Compartment Load BTU’s Total Equipment Capacity BTU’s Pilot House (03‐27‐0) 52730 53000 Radio Room (03‐33‐2) 21355 24000 Chart Room (03‐36‐0) 19963 24000 Aft Radio Room (03‐39‐2) 19262 24000 Captain’s Office (02‐24‐1) 14556 15000 XO Office (02‐24‐2) 14157 15000 XO Stateroom (02‐31‐2) 11540 12000 CO Stateroom (02‐37‐3) 11540 12000 Stateroom (02‐40‐2) 11540 12000 Stateroom (01‐34‐1) 9771 12000 Stateroom (01‐34‐4) 10220 12000 Stateroom (01‐39‐1) 10071 12000 Stateroom (01‐39‐2) 8708 12000 Stateroom (01‐43‐4) 10559 12000 Total 225972 BTU’s 251000 BTU’s

Use 1 size PQRY‐P240YSHMU‐BS‐A Water Cooled Condensing Unit Total System Capacity: 240000 BTU’s

System 2

Compartment Total Compartment Load BTU’s Total Equipment Capacity BTU’s CHENG Office (01‐19‐1) 14781 15000 Operations Officer Office (01‐19‐2) 14544 15000 CHENG Stateroom (01‐25‐1) 9473 12000 Operations Officer SR (01‐23‐2) 11529 12000 1st Asst Engineer SR (01‐29‐2) 9291 12000 GSM Stores (1‐8‐1) 25826 27000 Passage (1‐8‐0) 6375 8000 Mess Deck (1‐16‐1) 67143 72000 Chief Steward’s Office (1‐25‐4) 10221 12000 Dry Stores (1‐25‐2 7116 8000 Lounge (1‐30‐1) 18279 20000 Hospital (1‐42‐1) 14259 15000

Total 208837 BTU’s 228000 BTU’s

System 3

Ship’s Storage (2‐8‐2) 8361 12000 GSM Stores (2‐8‐1) 14604 15000 Scientific Stores (2‐22‐3) 6540 8000 Scientific Stores (2‐22‐2) 27013 30000 Stateroom (2‐25‐2) 10225 12000 Stateroom (2‐30‐1) 7078 12000 Stateroom (2‐34‐1) 14503 15000 Stateroom (2‐34‐2) 13010 15000 Stateroom (2‐39‐1) 13356 15000 Stateroom (2‐39‐2) 11963 12000 Stateroom (2‐43‐1) 13453 15000 Stateroom (2‐43‐2) 11963 12000 Stateroom (2‐47‐1) 13854 15000 Stateroom (2‐47‐2) 11963 12000 Stateroom (2‐51‐1) 14847 15000 Stateroom (2‐51‐2) 14233 15000 Exercise Room (3‐22‐0) 20649 24000 Total 227615 BTU’s 254000 BTU’s

System 4

SSFC/UPS Space (1‐32‐2) 9838 12000 Plot Room (1‐32‐4) 109050 114000

MCS (2‐63‐1) 68243 69000

Dive Locker (1‐77‐0) 33037 36000

Total 220168 BTU’s 231000 BTU’s

SW Cooling System Piping Calculations

Summary:

The new design of the saltwater cooling system for the cold side of the Plate Heat Exchangers is sufficient to provide proper coolant flow. System is designed to operate using only one heat exchanger and one pump at a time. Please refer to detailed piping system pressure loss data attached.

2 1/2" Flow: 199.6 gpm

4" Flow: 199.6 gpm

2 1/2"(2) Flow: 199.6 gpm

Pipe 1 Flow: --

CLOSED

Flow: --

CLOSED PIPE

Flow: --

Pipe 5 Flow: 199.6 gpm

Pipe Flow: --

Pipe 7 Flow: 200 gpm

Pipe 8 Flow: 199.6 gpm

Pipe 9 Flow: 199.6 gpm

Pipe 10 Flow: --

Pipe 12 Flow: 199.6 gpm

Pipe 11 Flow: 200 gpm

Pipe 13 Flow: --

Pipe 14 Flow: 200 gpm

Pipe 15 Flow: 200 gpm

Pipe 16 Flow: 200 gpm

EXST 6" PIPE

Flow: 200 gpm

Pipe 17 Flow: 99.15 gpm

Pipe 18 Flow: 199.6 gpm

Pipe 19 Flow: --

Pipe 21 Flow: 100.5 gpm

Pipe 22 Flow: --

Pipe 20 Flow: 199.6 gpm

Pipe 23 Flow: 199.6 gpm

Pipe 24 Flow: 199.6 gpm

Pipe 25 Flow: --

Pipe 6 Flow: 199.6 gpm

Pipe 26 Flow: 199.6 gpm

SEAWATER PUMP NO.2

Op: Fixed Speed TH: 130 ft

P: 55.42 psi g

P: 55.06 psi g

P: 54.32 psi g

P: 43.41 psi g

P: 41.66 psi g

HEAT EXCHANGER

dP: 8.68 psi

P: 28.11 psi g

DUPLEX STRAINER EATON 53BTX

dP: 8.5 psi

P: 40.32 psi g

P: 40.89 psi g

P: 27.03 psi g

P: 22.59 psi g

P: 20.78 psi g

P: 20.7 psi g Flow Demand P: 20.99 psi g

SEACHEST TO SEA WATER(1)

Set P: 0 psi g Level: 14 ft

SEACHEST TO SEA WATER

Set P: 0 psi g Level: 14 ft

P: 3.542 psi g

P: 2.763 psi g

P: 2.188 psi g

P: 1.969 psi g

SW PUMP FOR

EMERGENCY USE

SW OVBD

DISCH

CLOSED FOR AUX PUMP

BACK-UP

Seawater piping.pipe psi

Lineup:

ft

Power:

<Design Case>psi a

Program Version:

Maximum Iterations:

File Name:

Marine Systems Corp.

Velocity:

Drawn by:Density:

in

Flow rate:

cP

Company:

Calculation Method:

Elevation:

lb/ft³ gpm

0.01

14.1.33363

Project Information

Viscosity:

2100 14.7 ft/s ft Thursday, July 23, 2015 01:28 PM

PIPE-FLO Professional 14

Print Date:

Temperature:

Size:

Project:

Laminar Cutoff Re: Atmospheric Pressure:

Pressure:

°F

Units Used

NOAA TJ

hp Darcy-Weisbach

Iteration Tolerance:

Length:

File Name:

Lineup:

Atmospheric Pressure:

Company:

Project:

by:

Date:

Marine Systems Corp.

NOAA TJ

Darcy-WeisbachCalculation Method:

Laminar Cutoff Re: 2100

Max Iterations:

Iteration Tolerance:

0.01 Thursday, July 23, 2015 01:31 PM

Seawater piping.pipe <Design Case>

14.7 psi a

Progam Name: PIPE-FLO Professional 14 14.1.33363Version:

List Report

Specification Name Material ScheduleValve Table

Absolute Roughness Hazen Williams C Factor

Sizing Criteria Velocity Pressure

Pipe Specifications Design Limits

Reynolds Number

CUnI Copper Nickel MIL-T-16420K Class 200 150

6E-05 in 0.0 ft/sto to psi g to standard Schedule:

ViscosityTemperature Fluid Zone Name Density

PressureTable Name Vapor Pressure

Critical Pressure Specific Heat Ratio (k)

Fluid Zones

Fluid State Relative Molecular Mass inlet-seawater Seawater 3.5% Salinity

85 °F Liquidpsi g60 lb/ft³63.8

0.871 cP

0.5846 psi a psi a3199 outlet sea water Seawater 3.5% Salinity

95 °F Liquidpsi g46 lb/ft³63.67

0.753 cP

0.8 psi a psi a3199

Centrifugal Pumps Pump Name

NPSHr Flow RateTest Speed Total Head NPSHa

Suction Pressure Design NPSH Margin RatiodP Power

EfficiencyDischarge ElevationSuction Elevation Discharge PressureOperating Speed BEP Efficiency

SEAWATER PUMP NO.2

Carver

199.6 gpm8.91 ft

59.34 psi g

--36.27 ft

4.992 ft

-- --from to Manual Pump

57.61 psi

Fixed Speed -- 3600 rpm 8.4 ft

1.959 psi g 130 ft

Curve:

Company:

POR:

3x2.5x7-BD

5.9375 in

Size:

Type:

Diameter:

rpm3600

Specification Flow Rate

Fluid Zone Fluid Velocity

Pipeline Name Total dPSize V&F Resistance K

Total Head LossLength Reynolds Number

V&F Friction Factor

Pipelines

Pipe Friction Factor V&F dP

V&F Head Loss

Inside Diameter

Outlet Elevation

Inlet Elevation Outlet Total PressureInlet Total PressureInlet Device

Outlet Device Inlet Energy Grade Outlet Energy Grade Inlet Hydraulic Grade Outlet Hydraulic Grade

Outlet Static PressureInlet Static Pressure

2 1/2"

6.5 ft

2.5 in 3.927 inlet-seawater psi

2.364

11.11 0.80 199.6 ft ft/s8.91 gpm

Node 1

15.41 ft

SEAWATER PUMP NO.2

ftCUnI

0.01494 273402

0.01782 psi

1.538 ft

0.6816

2.709 in 54.57

59.34 psi g psi g psi g

55.42 58.49 psi g ft ft142.9

140.9 ft

138.6 140.5 ft

2 1/2"(2)

11.58 ft

2.5 in 0.7399 inlet-seawater psi

4.82

11.11 1.75 199.6 ft ft/s15.4 gpm

Node

12.25 ft

Node 2 ftCUnI

0.01494 273402

0.01782 psi

3.35 ft

1.484

2.709 in 53.47

55.06 psi g psi g psi g

54.32 54.21 psi g ft ft139.7

137.8 ft

134.9 ft

4"

40 ft

4 in 0.3522 inlet-seawater psi

0.8049

4.447 0.80 199.6 ft ft/s15.41 gpm

Node 2

15.4 ft

Node 1 ftCUnI

0.0162 172968

0.01607 psi

0.2469 ft 0.1094

4.282 in 54.93 55.42 psi g psi g psi g

55.06 55.28 psi g ft ft140.5

140.2 ft

139.4 139.7 ft

CLOSED

2 ft

2 in --inlet-seawater -- -- 0.00

15.4 Node 4

15.4 ft

Node 2 ftCUnI

2.209 in --

Page 1List Report Thursday, July 23, 2015 01:31 PMPIPE-FLO Professional 14 14.1.33363Version:

Specification Flow Rate

Fluid Zone Fluid Velocity

Pipeline Name Total dPSize V&F Resistance K

Total Head LossLength Reynolds Number

V&F Friction Factor

Pipelines

Pipe Friction Factor V&F dP

V&F Head Loss

Inside Diameter

Outlet Elevation

Inlet Elevation Outlet Total PressureInlet Total PressureInlet Device

Outlet Device Inlet Energy Grade Outlet Energy Grade Inlet Hydraulic Grade Outlet Hydraulic Grade

Outlet Static PressureInlet Static Pressure

CLOSED PIPE

50 ft

2.5 in --inlet-seawater -- -- 0.00

15.41

SEAWATER PUMP NO.1

8.4 ft

Node 1 ftCUnI

2.709 in --

EXST 6" PIPE

5 ft

6 in -0.2873 outlet sea water psi

0.01018

2.022 0.00 ft ft/s15.41 gpm

Flow Demand

14.75 ft

Node 15 ftCUnI

0.01698 134777

0.01476 psi 0 ft

6.357 in 20.96 20.7 psi g psi g psi g

20.99 20.67 psi g ft ft62.22

62.16 ft

62.15 62.21 ft

Pipe

5 ft

1.5 in --inlet-seawater -- -- 0.00

14.83 Node 7

14.83 ft

Node 6 ftCUnI

1.756 in --

Pipe 1

2 ft

2.5 in --inlet-seawater -- -- 0.05

12.25 Node 3

12.25 ft

Node ftCUnI

2.709 in --

Pipe 10

1.6 ft

2.5 in --inlet-seawater -- -- 0.05

11.75 Node 9

11.75 ft

Node 8 ftCUnI

2.709 in --

Pipe 11

1.833 ft

2 in 1.08 outlet sea water psi

0.6122

16.74 0.00 ft ft/s11.75 gpm

Node 12

13.58 ft

Node 8 ftCUnI

0.01411 387857

0.01869 psi 0 ft

2.209 in 25.1 28.11 psi g psi g psi g

27.03 26.18 psi g ft ft75.32

70.96 ft

70.35 74.7 ft

Pipe 12

1.56 ft

2 in 1.918 inlet-seawater psi

5.399

16.71 1.12 199.6 ft ft/s9.45 gpm

HEAT EXCHANGER

8.38 ft

Node 11 ftCUnI

0.01446 335286

0.01869 psi

4.867 ft 2.156

2.209 in 37.05 40.89 psi g psi g psi g

38.97 38.97 psi g ft ft101.7

97.41 ft

92.01 96.35 ft

Pipe 13

6.2 ft

2.5 in --inlet-seawater -- -- 0.00

9.45 Node 12

13.58 ft

Node 11 ftCUnI

2.709 in --

Pipe 14

7.769 ft

2 in 4.439 outlet sea water psi

8.21

16.74 1.29 ft ft/s13.58 gpm

Node 13

15.41 ft

Node 12 ftCUnI

0.01411 387857

0.01869 psi

5.616 ft 2.483

2.209 in 20.66 27.03 psi g psi g psi g

22.59 25.1 psi g ft ft74.7

70.35 ft

62.14 66.49 ft

Pipe 15

5.25 ft

2.5 in 1.806 outlet sea water psi

4.084

11.13 1.78 ft ft/s15.41 gpm

Node 14

15.41 ft

Node 13 ftCUnI

0.01456 316270

0.01782 psi

3.432 ft 1.517

2.709 in 19.93 22.59 psi g psi g psi g

20.78 21.74 psi g ft ft66.49

64.57 ft

60.48 62.41 ft

Pipe 16

1.5 ft

2.5 in 0.08237 outlet sea water psi

0.1863

11.13 0.00 ft ft/s15.41 gpm

Node 15

15.41 ft

Node 14 ftCUnI

0.01456 316270

0.01782 psi 0 ft

2.709 in 19.85 20.78 psi g psi g psi g

20.7 19.93 psi g ft ft62.41

60.48 ft

60.3 62.22 ft

Page 2List Report Thursday, July 23, 2015 01:31 PMPIPE-FLO Professional 14 14.1.33363Version:

Fluid Zone Fluid Velocity

Pipeline Name Total dPSize V&F Resistance K

Total Head LossLength Reynolds Number

V&F Friction Factor

Pipelines

Pipe Friction Factor V&F dP

V&F Head Loss

Inside Diameter

Outlet Elevation

Inlet Elevation Outlet Total PressureInlet Total PressureInlet Device

Outlet Device Inlet Energy Grade Outlet Energy Grade Inlet Hydraulic Grade Outlet Hydraulic Grade

Outlet Static PressureInlet Static Pressure

Pipe 17

21 ft

12 in 2.661 inlet-seawater psi

5.778E-03

0.2699 4.62

99.15 ft ft/s0 gpm

Node 16 6 ft

SEACHEST TO SEA WATER(1)

ftCUnI

0.02349 30030

0.01291 psi 5.231E-03 ft 2.317E-03

12.25 in 3.541 6.202 psi g psi g psi g

3.542 6.202 psi g ft ft14 ft

13.99 13.99 ft

Pipe 18

19.3 ft

6 in 0.7785 inlet-seawater psi

0.1773

2.018 2.17 199.6 ft ft/s6 gpm

Node 17

7.58 ft

Node 16 ftCUnI

0.01748 116509

0.01476 psi

0.137 ft

0.0607

6.357 in 2.735

3.542 psi g psi g psi g

2.763 3.514 psi g ft ft13.99

13.93 ft

13.75 13.82 ft

Pipe 19

10 ft

2 in --inlet-seawater -- -- 2.94

7.58 Flow Demand 1

8.16 ft

Node 17 ftCUnI

2.209 in --

Pipe 20

2.35 ft

4 in 0.5747 inlet-seawater psi

0.4772

4.447 1.45 199.6 ft ft/s7.58 gpm

Node 18

8.4 ft

Node 17 ftCUnI

0.0162 172968

0.01607 psi

0.4445 ft 0.1969

4.282 in 2.052 2.763 psi g psi g psi g

2.188 2.627 psi g ft ft13.82

13.51 ft

13.03 13.34 ft

Pipe 21

15.25 ft

12 in 2.661 inlet-seawater psi

5.778E-03

0.2735 4.62

100.5 ft ft/s0 gpm

Node 16 6 ft

SEACHEST TO SEA WATER

ftCUnI

0.02342 30431

0.01291 psi 5.371E-03 ft 2.380E-03

12.25 in 3.541 6.202 psi g psi g psi g

3.542 6.202 psi g ft ft14 ft

13.99 13.99 ft

Pipe 22

5 ft

2.5 in --inlet-seawater -- -- 0.00

8.4 Node 18

8.4 ft

SEAWATER PUMP NO.1

ftCUnI

2.709 in --

Pipe 23

4.25 ft

4 in 0.219 inlet-seawater psi

0.4943

4.447 1.42 199.6 ft ft/s8.4 gpm

Node 19

8.4 ft

Node 18 ftCUnI

0.0162 172968

0.01607 psi

0.435 ft

0.1927

4.282 in 1.833

2.188 psi g psi g psi g

1.969 2.052 psi g ft ft13.34

13.03 ft

12.54 12.85 ft

Pipe 24

0.5 ft

3 in 0.01069 inlet-seawater psi

0.02412

7.443 0.00 199.6 ft ft/s8.4 gpm

SEAWATER PUMP NO.2

8.4 ft

Node 19 ftCUnI

0.01546 223761

0.01702 psi 0 ft

3.31 in 1.577 1.969 psi g psi g psi g

1.959 1.588 psi g ft ft12.85

11.98 ft

11.96 12.82 ft

Pipe 25

5 ft

4 in --inlet-seawater -- -- 0.00

8.4 Node 20

8.4 ft

Node 19 ftCUnI

4.282 in --

Pipe 26

2.95 ft

2 in -0.5733 inlet-seawater psi

1.006

16.71 0.00 199.6 ft ft/s11.75 gpm

Node 11

9.45 ft

Node 9 ftCUnI

0.01446 335286

0.01869 psi 0 ft

2.209 in 38.97 40.32 psi g psi g psi g

40.89 38.4 psi g ft ft102.8

98.42 ft

97.41 101.7 ft

Pipe 5

2.75 ft

2.5 in 1.752 inlet-seawater psi

1.375

11.11 0.53 199.6 ft ft/s12.25 gpm

Node 6

14.83 ft

Node 3 ftCUnI

0.01494 273402

0.01782 psi

1.026 ft

0.4544

2.709 in 40.81

43.41 psi g psi g psi g

41.66 42.56 psi g ft ft110.2

108.3 ft

108.9 ft

Page 3List Report Thursday, July 23, 2015 01:31 PMPIPE-FLO Professional 14 14.1.33363Version:

Fluid Zone Fluid Velocity

Pipeline Name Total dPSize V&F Resistance K

Total Head LossLength Reynolds Number

V&F Friction Factor

Pipelines

Pipe Friction Factor V&F dP

V&F Head Loss

Inside Diameter

Outlet Elevation

Inlet Elevation Outlet Total PressureInlet Total PressureInlet Device

Outlet Device Inlet Energy Grade Outlet Energy Grade Inlet Hydraulic Grade Outlet Hydraulic Grade

Outlet Static PressureInlet Static Pressure

Pipe 6

3.66 ft

2 in 1.345 inlet-seawater psi

6.115

16.71 1.12 199.6 ft ft/s14.83 gpm

Node 9

11.75 ft

Node 6 ftCUnI

0.01446 335286

0.01869 psi

4.867 ft 2.156

2.209 in 38.4 41.66 psi g psi g psi g

40.32 39.74 psi g ft ft108.9

104.5 ft

98.42 102.8 ft

Pipe 7

3.81 ft

2.5 in 1.655 outlet sea water psi

1.571

11.13 0.57 ft ft/s9.578 gpm

Node 8

11.75 ft

HEAT EXCHANGER

ftCUnI

0.01456 316270

0.01782 psi

1.098 ft

0.4856

2.709 in 27.26

29.76 psi g psi g psi g

28.11 28.91 psi g ft ft76.89

74.96 ft

73.39 75.32 ft

Pipe 8

3.4 ft

2.5 in -0.4459 inlet-seawater psi

2.244

11.11 0.94 199.6 ft ft/s12.25 gpm

DUPLEX STRAINER EATON 53BTX

9 ft

Node ftCUnI

0.01494 273402

0.01782 psi

1.812 ft

0.8027

2.709 in 53.92

54.32 psi g psi g psi g

54.77 53.47 psi g ft ft134.9 ft

130.7 132.6 ft

Pipe 9

3.9 ft

2.5 in 2.856 inlet-seawater psi

3.196

11.11 1.41 199.6 ft ft/s9 gpm

Node 3

12.25 ft

DUPLEX STRAINER EATON 53BTX

ftCUnI

0.01494 273402

0.01782 psi

2.701 ft 1.197

2.709 in 42.56 46.27 psi g psi g psi g

43.41 45.42 psi g ft ft113.4

111.5 ft

108.3 110.2 ft

Bottom ElevationTank Name Hydraulic GradeSurface Pressure Liquid Level

Tanks

Bottom PressureFluid Zone Pipeline Flow Rate Pressure at PenetrationPenetration Height Connecting Pipelines

Pipeline Name ft 0 140 inlet-seawater SEACHEST TO SEA WATER ft

6.202 ft

14 psi g psi g

0 ftPipe 21 100.5 gpm psi g6.202 ft 0 140 inlet-seawater SEACHEST TO SEA WATER(1) ft

6.202 ft

14 psi g psi g

0 ftPipe 17 99.15 gpm psi g6.202

Flow RateFixed dP Device Name Head Loss

Fixed dP Devices dPInlet Elevation

Inlet Pressure Outlet Elevation Outlet Pressure

DUPLEX STRAINER EATON 53BTX 9 ft

54.77 psi g psi g

9 ft 46.27

8.5 ft

199.6 gpm 19.19 psi

HEAT EXCHANGER 8.38 ft

38.97 psi g psi g

9.578 ft 29.76

8.68 ft

199.6 gpm 19.59 psi

Nodes PressureNode Name Hydraulic GradeElevation

Flow Demand 1 8.16 ft -- --

Node 12.25 ft 54.32 psi g 133 ft

Node 1 15.41 ft 55.42 psi g 139.4 ft

Node 11 9.45 ft 40.89 psi g 97.41 ft

Node 12 13.58 ft 27.03 psi g 70.35 ft

Node 13 15.41 ft 22.59 psi g 63.35 ft

Node 14 15.41 ft 20.78 psi g 60.48 ft

Page 4List Report Thursday, July 23, 2015 01:31 PMPIPE-FLO Professional 14 14.1.33363Version:

Nodes PressureNode Name Hydraulic GradeElevation

Node 15 15.41 ft 20.7 psi g 61.23 ft

Node 16 6 ft 3.542 psi g 13.97 ft

Node 17 7.58 ft 2.763 psi g 13.63 ft

Node 18 8.4 ft 2.188 psi g 13.03 ft

Node 19 8.4 ft 1.969 psi g 12.26 ft

Node 2 15.4 ft 55.06 psi g 138.6 ft

Node 20 8.4 ft -- --

Node 3 12.25 ft 43.41 psi g 108.3 ft

Node 4 15.4 ft -- --

Node 6 14.83 ft 41.66 psi g 105.7 ft

Node 7 14.83 ft -- --

Node 8 11.75 ft 28.11 psi g 72.18 ft

Node 9 11.75 ft 40.32 psi g 98.42 ft

SEAWATER PUMP NO.1 8.4 ft -- --

Hydraulic Grade Flow Rate PressureFlow Demand Name

Flow Demands Elevation Flow Direction

20.99ft gpm200ftFlow Demand psi g 62.1514.75 Flow out

Page 5List Report Thursday, July 23, 2015 01:31 PMPIPE-FLO Professional 14 14.1.33363Version:

SW Cooling System Piping Calculations

Summary:

The new design of the Chilled Water cooling on the cold Hot Side of the Plate Heat Exchangers is sufficient to provide proper coolant flow. System is designed to operate using only one heat exchanger and one pump at a time Existing Aurora pump was retained. Please refer to detailed piping system pressure loss data attached.

Pipe 1

Pipe 2

Pipe 3

Pipe 5

Pipe 6

Pipe 7

Pipe 8

Pipe 12

Pipe 31

Pipe 32

Pipe 37

Pipe 33

Pipe 38

Pipe 39

Pipe 40

Pipe 43

Pipe 44

Pipe 45

Pipe 46

Pipe 47

Pipe 48

Pipe 49

Pipe 52

Pipe 53

Pipe 54

Pipe 56

Pipe 57

Pipe 58

Pipe 60

Pipe 61

Pipe 62

Pipe 63

Pipe 64

Pipe 65

Pipe 66

Pipe 67

Pipe 68

Pipe 71

Pipe 72

Pipe 51

Pipe 75

Pipe 76

Pipe 78

Pipe 79

Pipe 77

Pipe

Pipe 70

Pipe 80

Pipe 82

Pipe 81

Heat Exchanger No.2

Heat Exchanger No.1

F ixed dP Dev ice

F ixed dP Dev ice 5

F ixed dP Dev ice 6

F ixed dP Dev ice 7

Fixed dP Device 8

Fixed dP Device 9

Fixed dP Device 10

Fixed dP Device 11

EXST CHW PUMP NO1 AURORA 341 2 X 2 1/2 X 7B

Op: Fixed Speed

EXPANSION TANK

Set P: 0 psi g Level: 1 ft

CHW SYS new.pipe psi

Lineup:

ft

Power:

<Design Case>psi a

Program Version:

Maximum Iterations:

File Name:

Marine Systems Corp.

Velocity:

Drawn by:Density:

in

Flow rate:

cP

Company:

Calculation Method:

Elevation:

lb/ft³

0.01

14.1.33363

Project Information

Viscosity:

2100 14.7 ft/s ft Friday, July 24, 2015 11:59 AM

PIPE-FLO Professional 14

Print Date:

Temperature:

Size:

Project:

Laminar Cutoff Re: Atmospheric Pressure:

Pressure:

°F

Units Used

NOAA TJ

hp Darcy-Weisbach

Iteration Tolerance:

Length:

File Name:

Lineup:

Atmospheric Pressure:

Company:

Project:

by:

Date:

Marine Systems Corp.

NOAA TJ

Darcy-WeisbachCalculation Method:

Laminar Cutoff Re: 2100

Max Iterations:

Iteration Tolerance:

0.01 Friday, July 24, 2015 11:59 AM

CHW SYS new.pipe <Design Case>

14.7 psi a

Progam Name: PIPE-FLO Professional 14 14.1.33363Version:

List Report

Specification Name Material ScheduleValve Table

Absolute Roughness Hazen Williams C Factor

Sizing Criteria Velocity Pressure

Pipe Specifications Design Limits

Reynolds Number

Carbon Steel Steel ASME B.36.10M 80 140

1.800E-03 in 0.0 ft/sto to psi g to standard Schedule:

ViscosityTemperature Fluid Zone Name Density

PressureTable Name Vapor Pressure

Critical Pressure Specific Heat Ratio (k)

Fluid Zones

Fluid State Relative Molecular Mass

50% ETHgLYCOL OUT OF H.E.

50% Dowfrost

95 °F Liquidpsi g26 lb/ft³64.63

3.642 cP

0.7242 psi a psi a1229

28.35

50% EtGLYCOL TO H.E.

50% Dowfrost

108 °F Liquidpsi g14.7 lb/ft³64.34

2.83 cP

1.068 psi a psi a1229

28.35

Centrifugal Pumps Pump Name

NPSHr Flow RateTest Speed Total Head NPSHa

Suction Pressure Design NPSH Margin RatiodP Power

EfficiencyDischarge ElevationSuction Elevation Discharge PressureOperating Speed BEP Efficiency

EXST CHW PUMP NO1 AURORA 341 2 X 2 1/2 X 7B --8.9 ft

-- --from to Manual Pump

Fixed Speed -- 3500 8.58 ft

Curve:

Company:

POR:

6.75 in

Size:

Type:

71 %

Diameter:

Orifice Meters Orifice Meter Name Elevation Flow Rate

Head LossOutlet Pressure dP Inlet Pressure

Orifice Meter

Thermal Expansion Factor:

Device Material: 0.75

26.25

--in ft

Alloy Steel

Expansibility Factor:Alloy Steel Pressure Ratio:

Pipe Material:

Tap dP: --

Discharge Coefficient:

Diameter Ratio (Beta):

Orifice Diameter:

Tap Arrangement: Corner

Orifice Meter 1

Thermal Expansion Factor:

Device Material: 0.75

26.25

--in ft

Alloy Steel

Expansibility Factor:Alloy Steel Pressure Ratio:

Pipe Material:

Tap dP: --

Discharge Coefficient:

Diameter Ratio (Beta):

Orifice Diameter:

Tap Arrangement: Corner

Orifice Meter 2

Thermal Expansion Factor:

Device Material: 0.75

26.25

--in ft

Alloy Steel

Expansibility Factor:Alloy Steel Pressure Ratio:

Pipe Material:

Tap dP: --

Discharge Coefficient:

Diameter Ratio (Beta):

Orifice Diameter:

Tap Arrangement: Corner

Page 1List Report Friday, July 24, 2015 11:59 AMPIPE-FLO Professional 14 14.1.33363Version:

Orifice Meters Orifice Meter Name Elevation Flow Rate

Head LossOutlet Pressure dP Inlet Pressure

Orifice Meter 3

Thermal Expansion Factor:

Device Material: 0.75

26.25

--in ft

Alloy Steel

Expansibility Factor:Alloy Steel Pressure Ratio:

Pipe Material:

Tap dP: --

Discharge Coefficient:

Diameter Ratio (Beta):

Orifice Diameter:

Tap Arrangement: Corner

Orifice Meter 4

Thermal Expansion Factor:

Device Material: 0.75

36.25

--in ft

Alloy Steel

Expansibility Factor:Alloy Steel Pressure Ratio:

Pipe Material:

Tap dP: --

Discharge Coefficient:

Diameter Ratio (Beta):

Orifice Diameter:

Tap Arrangement: Corner

Orifice Meter 5

Thermal Expansion Factor:

Device Material: 0.75

36.25

--in ft

Alloy Steel

Expansibility Factor:Alloy Steel Pressure Ratio:

Pipe Material:

Tap dP: --

Discharge Coefficient:

Diameter Ratio (Beta):

Orifice Diameter:

Tap Arrangement: Corner

Orifice Meter 6

Thermal Expansion Factor:

Device Material: 0.75

36.25

--in ft

Alloy Steel

Expansibility Factor:Alloy Steel Pressure Ratio:

Pipe Material:

Tap dP: --

Discharge Coefficient:

Diameter Ratio (Beta):

Orifice Diameter:

Tap Arrangement: Corner

Orifice Meter 7

Thermal Expansion Factor:

Device Material: 0.75

36.25

--in ft

Alloy Steel

Expansibility Factor:Alloy Steel Pressure Ratio:

Pipe Material:

Tap dP: --

Discharge Coefficient:

Diameter Ratio (Beta):

Orifice Diameter:

Tap Arrangement: Corner

Specification Flow Rate

Fluid Zone Fluid Velocity

Pipeline Name Total dPSize V&F Resistance K

Total Head LossLength Reynolds Number

V&F Friction Factor

Pipelines

Pipe Friction Factor V&F dP

V&F Head Loss

Inside Diameter

Outlet Elevation

Inlet Elevation Outlet Total PressureInlet Total PressureInlet Device

Outlet Device Inlet Energy Grade Outlet Energy Grade Inlet Hydraulic Grade Outlet Hydraulic Grade

Outlet Static PressureInlet Static Pressure

Pipe

4.4 ft

4 in --

50% EtGLYCOL TO H.E. -- -- 19.82

8.9 Node

12.75 ft

EXST CHW PUMP NO1 AURORA 341 2 X 2 1/2 X 7B

ftCarbon Steel

3.826 in --

Pipe 1

13.7 ft

3 in --

50% EtGLYCOL TO H.E. -- -- 0.00

12.75 Node 1

16.25 ft

Node ftCarbon Steel

2.9 in --

Pipe 12

6.33 ft

2 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.16

23.67 Node 7

28.58 ft

Node 8 ftCarbon Steel

1.939 in --

Page 2List Report Friday, July 24, 2015 11:59 AMPIPE-FLO Professional 14 14.1.33363Version:

Fluid Zone Fluid Velocity

Pipeline Name Total dPSize V&F Resistance K

Total Head LossLength Reynolds Number

V&F Friction Factor

Pipelines

Pipe Friction Factor V&F dP

V&F Head Loss

Inside Diameter

Outlet Elevation

Inlet Elevation Outlet Total PressureInlet Total PressureInlet Device

Outlet Device Inlet Energy Grade Outlet Energy Grade Inlet Hydraulic Grade Outlet Hydraulic Grade

Outlet Static PressureInlet Static Pressure

Pipe 2

6.1 ft

2 in --

50% EtGLYCOL TO H.E. -- -- 1.41

16.25 Heat Exchanger No.2

10.3 ft

Node 1 ftCarbon Steel

1.939 in --

Pipe 3

8 ft

3 in --

50% EtGLYCOL TO H.E. -- -- 2.10

16.25 Heat Exchanger No.1

10.3 ft

Node 1 ftCarbon Steel

2.9 in --

Pipe 31

0.8 ft

1.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 0.61

28.58 Node 20

28.5 ft

Node 7 ftCarbon Steel

1.5 in --

Pipe 32

2.25 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.99

28.5 Orifice Meter 3

26.25 ft

Node 20 ftCarbon Steel

1.278 in --

Pipe 33

3.1 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.48

28.5 Orifice Meter 2

26.25 ft

Node 20 ftCarbon Steel

1.278 in --

Pipe 37

1.875 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.03

26.25 Fixed dP Device

25.25 ft

Orifice Meter 3 ftCarbon Steel

1.278 in --

Pipe 38

3.1 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.37

26.25 Fixed dP Device 5

25.25 ft

Orifice Meter 2 ftCarbon Steel

1.278 in --

Pipe 39

4.6 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 9.60

24.3 Node 21

28.75 ft

Fixed dP Device 5 ftCarbon Steel

1.278 in --

Pipe 40

6.6 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 9.64

24.3 Node 21

28.75 ft

Fixed dP Device ftCarbon Steel

1.278 in --

Pipe 43

2.25 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.99

28.5 Orifice Meter

26.25 ft

Node 24 ftCarbon Steel

1.278 in --

Pipe 44

1.875 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.03

26.25 Fixed dP Device 6

25.25 ft

Orifice Meter ftCarbon Steel

1.278 in --

Page 3List Report Friday, July 24, 2015 11:59 AMPIPE-FLO Professional 14 14.1.33363Version:

Fluid Zone Fluid Velocity

Pipeline Name Total dPSize V&F Resistance K

Total Head LossLength Reynolds Number

V&F Friction Factor

Pipelines

Pipe Friction Factor V&F dP

V&F Head Loss

Inside Diameter

Outlet Elevation

Inlet Elevation Outlet Total PressureInlet Total PressureInlet Device

Outlet Device Inlet Energy Grade Outlet Energy Grade Inlet Hydraulic Grade Outlet Hydraulic Grade

Outlet Static PressureInlet Static Pressure

Pipe 45

3.1 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.48

28.5 Orifice Meter 1

26.25 ft

Node 24 ftCarbon Steel

1.278 in --

Pipe 46

3.1 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.37

26.25 Fixed dP Device 7

25.25 ft

Orifice Meter 1 ftCarbon Steel

1.278 in --

Pipe 47

4.6 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 9.60

24.3 Node 25

28.75 ft

Fixed dP Device 7 ftCarbon Steel

1.278 in --

Pipe 48

6.6 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 9.64

24.3 Node 25

28.75 ft

Fixed dP Device 6 ftCarbon Steel

1.278 in --

Pipe 49

3.75 ft

1.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.38

28.75 Node 26

28.75 ft

Node 21 ftCarbon Steel

1.5 in --

Pipe 5

14.8 ft

3 in --

50% ETHgLYCOL OUT OF H.E. -- -- 3.11

15.2 Node 3

21 ft

Node 2 ftCarbon Steel

2.9 in --

Pipe 51

5.4 ft

2 in --

50% ETHgLYCOL OUT OF H.E. -- -- 0.00

28.75 Node 37

23.67 ft

Node 26 ftCarbon Steel

1.939 in --

Pipe 52

5.4 ft

1.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 2.65

28.75 Node 26

28.75 ft

Node 25 ftCarbon Steel

1.5 in --

Pipe 53

4.58 ft

1.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 2.71

28.58 Node 24

28.5 ft

Node 7 ftCarbon Steel

1.5 in --

Pipe 54

7 ft

2 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.16

32.25 Node 28

38.4 ft

Node 29 ftCarbon Steel

1.939 in --

Pipe 55

0.8 ft

1.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 0.61

38.4 Node 30

38 ft

Node 28 ftCarbon Steel

1.5 in --

Page 4List Report Friday, July 24, 2015 11:59 AMPIPE-FLO Professional 14 14.1.33363Version:

Fluid Zone Fluid Velocity

Pipeline Name Total dPSize V&F Resistance K

Total Head LossLength Reynolds Number

V&F Friction Factor

Pipelines

Pipe Friction Factor V&F dP

V&F Head Loss

Inside Diameter

Outlet Elevation

Inlet Elevation Outlet Total PressureInlet Total PressureInlet Device

Outlet Device Inlet Energy Grade Outlet Energy Grade Inlet Hydraulic Grade Outlet Hydraulic Grade

Outlet Static PressureInlet Static Pressure

Pipe 56

1.875 ft

2 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.79

Orifice Meter 5

36.25 ft

Node 30 ftCarbon Steel

1.939 in --

Pipe 57

3 ft

2 in --

50% ETHgLYCOL OUT OF H.E. -- -- 0.93

36.25 Fixed dP Device 8

34 ft

Orifice Meter 5 ftCarbon Steel

1.939 in --

Pipe 58

3.1 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.48

Orifice Meter 4

36.25 ft

Node 30 ftCarbon Steel

1.278 in --

Pipe 59

3.1 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.37

36.25 Fixed dP Device 9

34 ft

Orifice Meter 4 ftCarbon Steel

1.278 in --

Pipe 6

43.7 ft

3 in --

50% ETHgLYCOL OUT OF H.E. -- -- 3.57

Node 4

21 ft

Node 3 ftCarbon Steel

2.9 in --

Pipe 60

5.2 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 9.60

33.3 Node 31

38.4 ft

Fixed dP Device 9 ftCarbon Steel

1.278 in --

Pipe 61

6.6 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 9.64

33.3 Node 31

38.4 ft

Fixed dP Device 8 ftCarbon Steel

1.278 in --

Pipe 62

1.875 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.99

Orifice Meter 7

36.25 ft

Node 32 ftCarbon Steel

1.278 in --

Pipe 63

3 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.03

36.25 Fixed dP Device 10

34 ft

Orifice Meter 7 ftCarbon Steel

1.278 in --

Pipe 64

3.1 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.48

Orifice Meter 6

36.25 ft

Node 32 ftCarbon Steel

1.278 in --

Pipe 65

3.1 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.37

36.25 Fixed dP Device 11

34 ft

Orifice Meter 6 ftCarbon Steel

1.278 in --

Page 5List Report Friday, July 24, 2015 11:59 AMPIPE-FLO Professional 14 14.1.33363Version:

Fluid Zone Fluid Velocity

Pipeline Name Total dPSize V&F Resistance K

Total Head LossLength Reynolds Number

V&F Friction Factor

Pipelines

Pipe Friction Factor V&F dP

V&F Head Loss

Inside Diameter

Outlet Elevation

Inlet Elevation Outlet Total PressureInlet Total PressureInlet Device

Outlet Device Inlet Energy Grade Outlet Energy Grade Inlet Hydraulic Grade Outlet Hydraulic Grade

Outlet Static PressureInlet Static Pressure

Pipe 66

5.2 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 9.60

33.3 Node 33

38 ft

Fixed dP Device 11 ftCarbon Steel

1.278 in --

Pipe 67

6.6 ft

1.25 in --

50% ETHgLYCOL OUT OF H.E. -- -- 9.64

33.3 Node 33

38 ft

Fixed dP Device 10 ftCarbon Steel

1.278 in --

Pipe 68

3.75 ft

1.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.38

38.4 Node 34

38 ft

Node 31 ftCarbon Steel

1.5 in --

Pipe 7

9.5 ft

2 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.16

Node 5

23.67 ft

Node 4 ftCarbon Steel

1.939 in --

Pipe 70

1.8 ft

1.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.23

Node 39

38 ft

Node 33 ftCarbon Steel

1.5 in --

Pipe 71

4.58 ft

1.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 2.71

38.4 Node 32

38 ft

Node 28 ftCarbon Steel

1.5 in --

Pipe 72

8.6 ft

2 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.62

23.67 Node 29

32.25 ft

Node 5 ftCarbon Steel

1.939 in --

Pipe 75

43.7 ft

3 in --

50% ETHgLYCOL OUT OF H.E. -- -- 3.70

Node 38

21.6 ft

Node 36 ftCarbon Steel

2.9 in --

Pipe 76

35 ft

2.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 5.10

23.67 Node 36

21 ft

Node 37 ftCarbon Steel

2.323 in --

Pipe 77

17.7 ft

2 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.47

Node 36

21 ft

Node 34 ftCarbon Steel

1.939 in --

Pipe 78

34 ft

3 in --

50% ETHgLYCOL OUT OF H.E. -- -- 3.19

21.6

EXST CHW PUMP NO1 AURORA 341 2 X 2 1/2 X 7B

8.58 ft

Node 38 ftCarbon Steel

2.9 in --

Page 6List Report Friday, July 24, 2015 11:59 AMPIPE-FLO Professional 14 14.1.33363Version:

Fluid Zone Fluid Velocity

Pipeline Name Total dPSize V&F Resistance K

Total Head LossLength Reynolds Number

V&F Friction Factor

Pipelines

Pipe Friction Factor V&F dP

V&F Head Loss

Inside Diameter

Outlet Elevation

Inlet Elevation Outlet Total PressureInlet Total PressureInlet Device

Outlet Device Inlet Energy Grade Outlet Energy Grade Inlet Hydraulic Grade Outlet Hydraulic Grade

Outlet Static PressureInlet Static Pressure

Pipe 79

7.6 ft

3 in --

50% ETHgLYCOL OUT OF H.E. -- -- 1.98

8.4 Node 2

15.2 ft

Heat Exchanger No.1 ftCarbon Steel

2.9 in --

Pipe 8

35 ft

2.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 5.10

Node 8

23.67 ft

Node 4 ftCarbon Steel

2.323 in --

Pipe 80

4.6 ft

1.5 in --

50% ETHgLYCOL OUT OF H.E. -- -- 2.65

Node 34

38 ft

Node 39 ftCarbon Steel

1.5 in --

Pipe 81

12.2 ft

1 in --

50% ETHgLYCOL OUT OF H.E. -- -- 0.99

Node 39

38 ft

Node 40 ftCarbon Steel

0.957 in --

Pipe 82

3.98 ft

1 in --

50% ETHgLYCOL OUT OF H.E. -- -- 2.19

41.08 Node 40

38 ft

EXPANSION TANK

ftCarbon Steel

0.957 in --

Bottom ElevationTank Name Hydraulic GradeSurface Pressure Liquid Level

Tanks

Bottom PressureFluid Zone Pipeline Flow Rate Pressure at PenetrationPenetration Height Connecting Pipelines

Pipeline Name ft 0 --41.08

50% ETHgLYCOL OUT OF H.E.

EXPANSION TANK

ft psi g

0 ftPipe 82 -- psi g0.4488

Flow RateFixed dP Device Name Head Loss

Fixed dP Devices dPInlet Elevation

Inlet Pressure Outlet Elevation Outlet Pressure

Fixed dP Device 25.25 ft

24.3 ft

Fixed dP Device 10 34 ft

33.3 ft

Fixed dP Device 11 34 ft

33.3 ft

Fixed dP Device 5 25.25 ft

24.3 ft

Fixed dP Device 6 25.25 ft

24.3 ft

Fixed dP Device 7 25.25 ft

24.3 ft

Fixed dP Device 8 34 ft

33.3 ft

Page 7List Report Friday, July 24, 2015 11:59 AMPIPE-FLO Professional 14 14.1.33363Version:

Flow RateFixed dP Device Name Head Loss

Fixed dP Devices dPInlet Elevation

Inlet Pressure Outlet Elevation Outlet Pressure

Fixed dP Device 9 34 ft

33.3 ft

Heat Exchanger No.1 10.3 ft

8.4 ft

Heat Exchanger No.2 10.3 ft

8.38 ft

Nodes PressureNode Name Hydraulic GradeElevation

Node 12.75 ft -- --

Node 1 16.25 ft -- --

Node 2 15.2 ft -- --

Node 20 28.5 ft -- --

Node 21 28.75 ft -- --

Node 24 28.5 ft -- --

Node 25 28.75 ft -- --

Node 26 28.75 ft -- --

Node 28 38.4 ft -- --

Node 29 32.25 ft -- --

Node 3 21 ft -- --

Node 30 38 ft -- --

Node 31 38.4 ft -- --

Node 32 38 ft -- --

Node 33 38 ft -- --

Node 34 38 ft -- --

Node 36 21 ft -- --

Node 37 23.67 ft -- --

Node 38 21.6 ft -- --

Node 39 38 ft -- --

Node 4 21 ft -- --

Node 40 38 ft -- --

Node 5 23.67 ft -- --

Node 7 28.58 ft -- --

Node 8 23.67 ft -- --

Page 8List Report Friday, July 24, 2015 11:59 AMPIPE-FLO Professional 14 14.1.33363Version:

Reference Material

Pump Data Sheet - CARVER PUMP COMPANY

Company: Carver Pump Co Name: Marine Office Date: 3/17/2015

Pump:

Size: 3x2.5x7-BD Type: M Series Speed: 3500 rpm Synch speed: 3600 rpm Dia: 5.9375 in Curve: Impeller:

Specific Speeds: Ns: ---

Nss: --- Dimensions: Suction: 3 in

Discharge: 2.5 in

Pump Limits:

Temperature: --- Power: --- Pressure: --- Eye area: --- Sphere size: ---

Search Criteria:

Flow: 280 US gpm Head: 112 ft

Fluid:

Seawater Temperature: 68 °F SG: 1.03 Vapor pressure: 1 psi a Viscosity: 1 cP Atm pressure: 14.7 psi a NPSHa: ---

Motor:

Size: 15 hp Speed: 3600 Frame: 254T

Standard: NEMA Enclosure: TEFC

Sizing criteria: Max Power on Design Curve

PUMP-FLO 10.6.2.0 Selected from catalog: Carver M-Series 60 Hz Vers: 3

---- Data Point ---- Flow: 280 US gpm Head: 112 ft Eff: 78% Power: 10.4 hp NPSHr: 10.3 ft

---- Design Curve ---- Shutoff head: 134 ft Shutoff dP: 59.9 psi Min flow: --- BEP: 79% @ 261 US gpm NOL power:

11.4 hp @ 343 US gpm

-- Max Curve -- Max power:

18.1 hp @ 424 US gpm

US gpm

P o w er h p

4504003503002502001501000 50

N P

S H r ft

4504003503002502001501000 50

H ea d f t

4504003503000 250

78.6

5.9375 in

7 in

5 in

Performance Evaluation:

Flow Speed Head Efficiency Power NPSHr US gpm rpm ft % hp ft 336 3500 92.5 71 11.3 15.8 280 3500 112 78 10.4 10.3 224 3500 126 78 9.37 6.4 168 3500 132 72 8.05 3.92 112 3500 135 60 6.53 3.17

Job Name:

Schedule Reference: Date:

Specifications are subject to change without notice.

© 2014 Mitsubishi Electric US, Inc.

Specifications System Module 1 Module 2 Unit Type PQRY-P240YSHMU-A PQRY-P120YHMU-A PQRY-P120YHMU-A

Nominal Cooling Capacity Btu/h 240,000 120,000 120,000 Nominal Heating Capacity Btu/h 270,000 135,000 135,000

Operating Temperature Range Cooling (Indoor)

Refer to Module Data

59~75° F (15~24° C) WB

Heating (Indoor) 59~81° F (15~27° C) DB

Operating Water Temperature Range

Cooling* 23~113° F (-5~45° C) Heating* 23~113° F (-5~45° C)

External Dimensions (H x W x D) In. / mm Refer to Module Data 43-5/16 x 34-11/16 x 21-11/16 / 1,100 x 880 x 550

43-5/16 x 34-11/16 x 21-11/16 / 1,100 x 880 x 550

Net Weight Lbs. / kg 856 / 388 428 / 194 428 / 194 External Finish Refer to Module Data Acrylic-painted Steel Sheets Electrical Power Requirements Voltage, Phase, Hertz Refer to Module Data** 460V, 3-phase, 60Hz Minimum Circuit Ampacity (MCA)** A Refer to Module Data** 14** 14** Maximum Fuse Size** A Refer to Module Data** 20** 20** Circulating Water (quality must meet regulations) Flow Rate GPM / L/s

Refer to Module Data

25 / 2 25 / 2 Pressure Drop Ft. / psi 6 / 3 6 / 3 Operation Volume Range GPM / L/m 20 - 32 / 75 - 120 20 - 32 / 75 - 120 Maximum Water Pressure MPa / psi 2 / 290 2 / 290 Water-source Connections (Each for Inlet and Outlet) In. Refer to Module Data** 1-1/2 FPT 1-1/2 FPT

Piping Diameter Refer to System DataFrom Twinning Kit to Indoor Units

(Brazed) (In. / mm) Liquid (High Pressure) 1-1/8 / 28.58 Gas (Low Pressure) 1-1/8 / 28.58

From Modules to Twinning Kit (Brazed) (In. / mm)

Liquid (High Pressure) Refer to Module Data

3/4 / 19.05 3/4 / 19.05 Gas (Low Pressure) 7/8 / 22.2 -

Max. Total Refrigerant Line Length Ft 2,461

Refer to System DataMax. Refrigerant Line Length Ft 541 Max. Control Wiring Length Ft 1,640

Indoor Unit Total Capacity 50 to 150% of WSUs

Refer to System Data Model / Quantity

P06 ~ P96 / 2 to 50 Max. No. Connectable

Branch Pipes: 48 Sound Pressure Levels dB(A) 54 51 51 Compressor Operating Range 7 - 100% Refer to System Data Compressor Type x Quantity

Refer to Module Data Inverter-driven Scroll Hermetic x 1 Inverter-driven Scroll Hermetic x 1

Compressor Motor Output kW 8.5 8.5 Compressor Crankcase Heater kW 0.051 0.051 Refrigerant

Refer to Module Data R410A

Lubricant MEL32 High-pressure Protection Device

Refer to Module Data 601 psi / 4.15 MPa 601 psi / 4.15 MPa

Compressor / Fan Protection Device Overheat Protection Overheat Protection Inverter Protection Device Overheat / Overcurrent Protection Overheat / Overcurrent Protection

Outdoor Unit: 20-TON PQRY-P240YSHMU-A (Consists of Two PQRY-P120YHMU and One CMY-Q100CBK Twinning Kit)

*If using circulating water temperatures between 23° and 50° F, Dip switch 3-9 must be turned on and glycol must be added to the water loop to prevent freezing down to 5° F.

** Each individual module requires a separate electrical connection. Reference electrical data for each individual module.

OPTIONAL PARTS

□ Twinning Kit (required).………….……..……….……..CMY-Q100CBK

□ Joint Kit...........................…for details see Pipe Accesories Submittal

□ BC Controller................….....for details see BC Controller Submittals

MODULAR WATER-SOURCE VRF HEAT PUMP SYSTEM

FEATURES

• Modular units connectable to expand capacity

• Designed for closed water loops

• Self-cooling cabinet design

• Compact size

• Connects to CITY MULTI indoor units

• Controlled via CITY MULTI Controls Network

Performance Specification

Customer: RW FERNSTRUM & COMPANY Date: 7/9/2015 Proposal No.:

Email: Run No.: 1081039 Cust. Reference: Item No.:

Technician: D.PEURA Model: GLD-013-H-4-NR-74 Units Required: 1

7.9.2015

The performance guarantee, if applicable, is based on the accuracy of the data presented above, and the customers ability to supply product and operating conditions in conformance with the above.

Tranter, Inc. P.O. Box 2289 Wichita Falls, TX 76306

Phn: (940) 723-7125 Fax: (940) 723-1131 3.0.0.228

Intended End Use: Heat exchanger to cool 50% EthGlycol (aq) 9.79 °F using 85 °F Sea Water with pressure drop at or below 15 psi on hot side and at or below 15 psi on cold side.

Hot Side Cold Side

Fluid Name 50% EthGlycol (aq) Sea Water

OPERATING DATA Inlet Outlet Inlet Outlet

Total Liquid flow GPM 240.00 240.00 200.00 200.00 GPM Operating Temperature °F 104.79 95.00 85.00 95.23 °F

Pressure drop (allowed / calc.) psi 15.00 / 14.81 15.00 / 8.68 psi Operating Pressure psi(g) 40.00 25.19 60.00 51.32 psi(g)

Total Heat Exchanged Btu/h 1,000,000

U-Service Btu/(h·ft²·°F) 1,031 Total Heat Transfer Area ft² 99.20

LMTD °F 9.78

FLUID PROPERTIES Inlet Outlet Inlet Outlet

Specific Gravity - 1.05 1.05 1.02 1.02

Specific Heat Btu/(lb·°F) 0.81 0.81 0.96 0.96 Thermal Conductivity Btu/(h·ft·°F) 0.24 0.24 0.35 0.35

Viscosity (avg.) cP 2.11 2.43 0.86 0.77

CONNECTIONS

Position S1 S3 S2 S4

Type THREADED THREADED THREADED THREADED Size 2" 2" 2" 2"

Material 316L SS Ti

CONSTRUCTION

Pass Arrangement 1 1

Channel Arrangement 36H+0H 37H+0H

A-Dimension / C-Dimension in 9.62 / 34 Plate Material (Material/Thickness) Ti / 0.4 mm

Gasket Material (Hot/Cold) NBR NBR No. of Plates 74

Frame material / Paint / Color SA-516-70 Carbon Steel / Enamel / RAL 5012 (Royal Blue) Tightening Bolts/Nuts/Finish SA-193-B7 Carbon Steel / 8/2H Tie Nuts / FZB

Pressure (design / test) psi(g) 100.00 / 130.00 100.00 / 130.00

Temperature (min / design) °F 14.00 / 150.00 14.00 / 150.00 Weight empty / flooded (per unit) lbs 369 / 424

Pressure vessel code ASME

Remarks:

Dimensions are for reference purposes only and are not to be used for construction.

Property of Tranter, Inc. and not to be reproduced without their consent nor used in any manner detrimental to the interest of Tranter, Inc..

SUPERCHANGER ASSEMBLY

GLD-013-H-4-NR-74

Sizing Number 1081039

Job Name:
Schedule Reference:
Date:
Twinning Kit required: On
Joint Kit: Off
BC Controller: Off

File details come from the government source that posted it. Updated .