Material Qualification Checklist Summary
This Material Qualification Checklist is a detailed evaluation tool developed by the Washington Suburban Sanitary Commission (WSSC Water) in Maryland for assessing Advanced Metering Infrastructure (AMI) components submitted by manufacturers. The checklist covers four primary product categories: water meters (positive displacement, turbine, and ultrasonic types in sizes ranging from 5/8" to 12"), transmitters for automated meter reading, composite meter pit lids, and associated meter accessories. Manufacturers must submit complete documentation and physical samples by December 11, 2026, at 2:00 pm via WSSC's eProcurement Portal, with materials delivered to the Meter Shop located at 4102 Lloyd Street, Building 6, Hyattsville, Maryland. The qualification process operates on a rolling basis, with evaluated materials and approved vendors posted publicly on wsscwater.com/AMI-Materials-RFQu. Submittals require manufacturer-provided return slips, detailed specifications on advanced metering capabilities, battery life expectations, weatherproofing standards, and climate requirements, followed by eight-week field testing periods for transmitters and composite lids to verify performance, durability, and compatibility with WSSC Water's existing infrastructure.
The checklist establishes rigorous technical and packaging requirements to ensure product quality and operational standardization. Meters must comply with AWWA standards C-700, C-710, C-701, C-703, C-715-18, and C-750-19, along with NSF/ANSI Standards 61 and 372, with manufacturers providing certificates of test accuracy and lifetime warranties of not less than ten years from acceptance. Acceptance criteria mandate that fewer than three percent of randomly sampled units from each shipment (10 percent sample size) fail accuracy requirements of 98.5 to 101.5 percent across flow rates. Delivery packaging requirements are highly specific, including individual cartons on 42" x 42" pallets stacked no higher than 40 inches, with detailed labeling requirements on all four pallet sides, serial number organization, and weight specifications for large meters. Composite lids must fit standard WSSC Water circular meter pits at 9-inch, 12-inch, or 21-inch diameters and support three read modes: Advanced Metering Infrastructure (AMI), Automated Meter Reading (AMR), and manual touch read. No contract value or pricing information is specified in this qualification; evaluation is based solely on technical compliance with the detailed checklists provided.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 - Required Meter Submittals
| Manufacturer Name: | Meter Type and Size | |||||||||||||||||||||||||||
| Positive Displacement | Ultrasonic | Turbine | Fire Service (FM) | |||||||||||||||||||||||||
| 5/8" x 5/8" | 5/8" x 3/4" | 3/4" | 1" | 1 1/2" | 2" x 17" | 2" x 15.25" | 5/8" | 3/4" | 1" | 1 1/2" | 2" x 15.25" | 2" x 17" | 3" | 4" | 6" | 8" | 10" | 12" | 3" | 4" | 6" | 4" | 6" | 8" | 10" | 12" | ||
| No. | Meter Submittals | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: | Model: |
| Minimum Requirement | Does this meter meet WSSC Water Specification? | |||||||||||||||||||||||||||
| 1 | Manufacturer-provided return slip, for samples to be returned after WSSC Water review | |||||||||||||||||||||||||||
| 2 | Advanced Metering Infrastructure (AMI) and/or Automated Meter Reading (AMR) read mode and programmability | |||||||||||||||||||||||||||
| 3 | Register resolution and programmability | |||||||||||||||||||||||||||
| 4 | Expected battery life for digital components | |||||||||||||||||||||||||||
| 5 | Climate requirements | |||||||||||||||||||||||||||
| 6 | Weatherproofing standards |
| Meter Evaluation Checklist (WSSC Water Use) | |
| 1 | Meter demonstrates read accuracy per AWWA standard on a test bench in a shop setting. |
| 2 | Over an eight-week field testing period, meter provides visual read of water usage, either via digital or analog register. |
&F &A Page &P of &N
2 - Required Meter Accessories
| Manufacturer Name: | |
| Meter Model: | |
| No. | Required Meter Accessories |
tc={B722D515-38D1-47AF-9690-DF107E303C43}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
[Tasks]
There is a task anchored to this comment that cannot be viewed in your client.
Comment:
| @Patterson, Christin is there an accessories sheet needed for transmitters or composite lids? | Yes | No | N/A |
| 1 | The accessories shall be included in each meter package based on the type. | ||
| 2 | A quantity of 2 gaskets shall be provided for each 5/8" through 1" meter. Gaskets shall be shipped in cartons marked "gaskets". Gaskets shall be packed in bags of 200 each and marked with quantity and size. | ||
| 3 | Each shipment shall include a document with the manufacturer's instructions on how to read the register and how to interpret the register sweep hand/display, or those instructions must be easily available on the manufacturer’s website. | ||
| 4 | Small outside meters shall require a pit pad. It shall be black in color, and of a sturdy and tamperproof construction. Materials employed shall be corrosion resistant, resistant to ultraviolet degradation, unaffected by rain or condensation, and compatible with rugged service and long life. | ||
| 5 | The pit pads shall allow for ease of installation on any meter pit lid (plastic, cast iron or composite) that has a 1.75" diameter hole in the lid and shall be between 4.0" and 4.375" in outside diameter. The overall thickness of the exposed portion of the pit pad shall not exceed 0.375". | ||
| 6 | Small inside meters shall require a wall pad with two terminal connections, and two mounting holes set 180 degrees apart. | ||
| 7 | Large meters shall have the correct number of bolts, nuts and washers made of bronze or stainless-steel meeting the requirements of AWWA C-700 (latest revision) with the exception of the nuts and bolts for external flanges. Nuts and bolts for external flanges shall be of type 316, and or 430 stainless steel with fluoropolymer coating and or coating to prevent galling. Two ring/drop gaskets with one or more annular rings molded into the gasket, shall be furnished with each meter. The required quantities of nuts and bolts for each size of meter are as follows: | ||
| Size Quantity | |||
| 7A | 1.5” 4 | ||
| 7B | 2” 4 | ||
| 7C | 3” 8 | ||
| 7D | 4” 16 | ||
| 7E | 6 - 8” 16 | ||
| 7F | 10 - 12” 24 |
@Patterson, Christin is there an accessories sheet needed for transmitters or composite lids?
&F &A Page &P of &N
3 - Meter Delivery Packaging
| Manufacturer Name: | |
| Meter Model: | |
| No. | Required Packaging - Delivery |
tc={EDCF0889-4CD1-411C-AA3B-2C15AF940B60}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
[Tasks]
There is a task anchored to this comment that cannot be viewed in your client.
Comment:
| @Patterson, Christin are there specific delivery requirements we need to add for transmitters or composite lids? | Yes | No | N/A |
| 1 | Each meter shall be packaged, large meters individually, in a suitable wooden carton or box which provides adequate protection from damage. | ||
| 2 | A certificate of test accuracy shall be supplied with each delivered meter which attests that the meter registers at or within the accuracy parameters stated per meter type and size attached. | ||
| 3 | The test tags shall be affixed to each meter and shall state the meter test results (showing that the meter is accurate at minimum, intermediate, and maximum flows), the date of manufacture, the test bench where it was tested, and the date of the test. | ||
| 4 | A summary file detailing meter serial numbers, test results, date of purchase, contract number and purchase order number in a Microsoft excel format shall be supplied to the Contract Manager via email. | ||
| 6 | Cartons will be stretch wrapped on 42" x 42" four-way entry perimeter base pallets, stacked no more than 40” high (including the height of the pallet). | ||
| 7 | Crates for 6” through 12” meters shall not exceed 40 inches in height and shall be suitable for forklift handling. | ||
| 8 | Pallets will be stretch wrapped and shall be marked on all four sides with manufacturer's name, meter size, WSSC stock number, delivery release number, serial number range of meters on pallet, and number of meters with one half inch size lettering or larger except for the WSSC stock number which shall be in one inch size lettering or larger. | ||
| 9 | Only one size meter per pallet will be accepted. | ||
| 10 | Cartons shall be stacked on pallets in serial number order with the lowest number on top and the highest on the bottom. Cartons on the outer sides of the stacks shall be stacked with the labels facing outward so they can be read without unstacking the cartons. | ||
| 11 | Cartons shall be labeled with the carton number, e.g., 1 of 50, 2 of 50, etc., the WSSC stock number, delivery release number, the manufacturer’s part number, manufacturer’s description, and serial number range within carton. | ||
| Large meter crates shall include weight in one inch size font or larger. | |||
| 12 | The crates shall be labeled with the WSSC stock number, WSSC purchase order number, manufacturer’s name, manufacturer’s approved part or model number, and size. | ||
| 13 | Failure to comply with these packaging requirements may be grounds for rejection of the shipment. |
@Patterson, Christin are there specific delivery requirements we need to add for transmitters or composite lids?
&F &A Page &P of &N
4 - Reqd Transmitter Submittals
| Manufacturer Name: | ||||
| Transmitter Model 1: | Transmitter Model 2: | Transmitter Model 3: | ||
| No. | Transmitter Submittals | |||
| 1 | Manufacturer-provided return slip, for samples to be returned after WSSC Water review | |||
| 2 | AMI and/or AMR read mode and programmability | |||
| 3 | Transmission data resolution and programmability | |||
| 4 | Radiofrequency range used for transmission, and licensed or unlicensed status | |||
| 5 | Transmission duration | |||
| 6 | Expected battery life | |||
| 7 | Climate requirements | |||
| 8 | Weatherproofing standards | |||
| 9 | List of compatible meter makes and models for transmitting reads, and indication of whether meter protocols are released | * |
| 10 | Physical samples of mechanism(s) for anchoring devices to exterior wall |
| 11 | Physical samples of mechanism(s) for anchoring devices to meter pit lid |
| Transmitter Evaluation Checklist (WSSC Water Use) | |
| 1 | Over an eight-week field testing period, transmitter can be successfully anchored to exterior wall and/or meter pit lid. |
| 2 | Over an eight week field testing period, transmitter material demonstrates flexibility to survive drop test from a height of eight feet. |
&F &A Page &P of &N
5 - Required Lid Submittals
| Manufacturer Name: | ||||
| Lid Model 1: | Lid Model 2: | Lid Model 3: | ||
| No. | Composite Lid Submittals | |||
| 1 | Manufacturer-provided return slip, for samples to be returned after WSSC Water review. Note that it will be in used condition | |||
| 2 | Size | |||
| 3 | Material description | |||
| 4 | Climate requirements | |||
| 5 | Weatherproofing standards | |||
| 6 | Scaled detail drawings | |||
| 7 | Load rating |
| Composite Lid Evaluation Checklist (WSSC Water Use) | |
| 1 | Lid fits standard WSSC Water circular meter pit at 9-inch, 12-inch, or 21-inch diameter. |
| 2 | Lid has significant weight to close securely when locked into pit frame. |
| 3 | Lids lays flush with ground cover to not pose a tripping hazard. |
| 4 | WSSC is able to capture a read through the lid via three reading modes to support current and future meter reading operations – Advanced Metering Infrastructure (AMI), Automated Meter Reading (AMR), and manual touch read. |