Map Location Floor Plan and Equipment Photos Building 7.pdf

PDF 2 MB Posted

Attached to
Z2JZ--Replace HVAC Units at Building 7 and 97, USCG Base Elizabeth CIty
Solicitation number
70Z08126QELIZ0020
Issued by

About this file

This document is a property reference and photographic exhibit for Building #7, a Multipurpose Building (Club) located at USCG Base Elizabeth City, with Real Property Unique Identifier 24001. The building is a single-story structure measuring approximately 64 feet by 59 feet, containing a ballroom as the primary space along with supporting rooms including offices, kitchen, dining area, game room, and storage areas. The building features a 9-foot floor-to-drop-ceiling height and is served by an existing HVAC system consisting of an outdoor air-cooled condenser unit (Model BWA180C3001A, Serial S10 198438) mounted on a 7-foot by 7-foot concrete pad located approximately 15 feet from ground to roof line, an air handler unit positioned above the drop ceiling (Model BWH180B300CA, Serial S180289), a Siemens RZU1 thermostat, approximately 9 supply diffusers, and approximately 6 return grilles with filters. The HVAC condenser requires two 27 RLA compressor motors rated at 200-230V 3-phase 60Hz and four 3.8 FLA outdoor fan motors rated at 200-230V 1-phase 60Hz. Condensate and refrigerant lines connect the outdoor condenser to the indoor air handler through the building exterior. The document includes site layout maps showing the building's location relative to the Pasquotank River and base access gates, exterior photographs from all cardinal directions, interior ballroom views, and detailed images of existing mechanical equipment and distribution systems.

Map and Photos Building 7

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Page 1 of 17 Reference (a)

Pasquotank River

Back Gate

Front Gate

Building# 7 – Multipurpose Building (Club)

Page 2 of 17 Reference (a) Real Property Unique Identifier - 24001

Page 3 of 17 Reference (a) East Side

Page 4 of 17 Reference (a) West Side

Page 5 of 17 Reference (a) South Side

Page 6 of 17 Reference (a)

Building# 7 Floor Plan

Existing

HVAC

Condenser

Existing Air Handler Above Drop

Ceiling

Thermostat Location

Ballroom

64’

59’

***All measurements are approximate***

Existing HVAC Outdoor Condenser

Page 7 of 17 Reference (a)

MODEL# BWA180C3001A 03/86

SERIAL# S10 198438

COMPR MOT (2) 27 RLA 200-230 V 3 PH 60 HZ

OD MOT (4) 3.8 FLA 200-230 V 1 PH 60 HZ

***All measurements are approximate***

Concrete Pad 7’ x 7’

15’ Ground to the

Roof Line

Existing HVAC Outdoor Condenser

Page 8 of 17 Reference (a)

Area for concrete over to the building

Area to concrete over to the building

Existing Condensate & Refrigerant Lines

Page 9 of 17 Reference (a)

Existing HVAC Air Handler Location

Page 10 of 17 Reference (a)

***All measurements are approximate***

Air Handler Location ABOVE the Drop Ceiling 9’ Floor to Drop Ceiling

MODEL# BWH180B300CA

SERIAL# S180289

03/86

Ballroom View #1

Page 11 of 17 Reference (a)

Ballroom View #2

Page 12 of 17 Reference (a)

Ballroom View #3

Page 13 of 17 Reference (a)

Ballroom View #4

Page 14 of 17 Reference (a)

Ballroom View #5

Page 15 of 17 Reference (a)

Ballroom View #6

Page 16 of 17 Reference (a)

Existing Thermostat

Existing Supply & Return Grille

Page 17 of 17 Reference (a)

Approximately 9 - Supply Diffusers

Approximately 6 - Return Grilles with Filter