Map Location Floor Plan and Equipment Photos Building 7.pdf
PDF 2 MB Posted
- Solicitation number
- 70Z08126QELIZ0020
About this file
This document is a property reference and photographic exhibit for Building #7, a Multipurpose Building (Club) located at USCG Base Elizabeth City, with Real Property Unique Identifier 24001. The building is a single-story structure measuring approximately 64 feet by 59 feet, containing a ballroom as the primary space along with supporting rooms including offices, kitchen, dining area, game room, and storage areas. The building features a 9-foot floor-to-drop-ceiling height and is served by an existing HVAC system consisting of an outdoor air-cooled condenser unit (Model BWA180C3001A, Serial S10 198438) mounted on a 7-foot by 7-foot concrete pad located approximately 15 feet from ground to roof line, an air handler unit positioned above the drop ceiling (Model BWH180B300CA, Serial S180289), a Siemens RZU1 thermostat, approximately 9 supply diffusers, and approximately 6 return grilles with filters. The HVAC condenser requires two 27 RLA compressor motors rated at 200-230V 3-phase 60Hz and four 3.8 FLA outdoor fan motors rated at 200-230V 1-phase 60Hz. Condensate and refrigerant lines connect the outdoor condenser to the indoor air handler through the building exterior. The document includes site layout maps showing the building's location relative to the Pasquotank River and base access gates, exterior photographs from all cardinal directions, interior ballroom views, and detailed images of existing mechanical equipment and distribution systems.
Map and Photos Building 7
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Page 1 of 17 Reference (a)
Pasquotank River
Back Gate
Front Gate
Building# 7 – Multipurpose Building (Club)
Page 2 of 17 Reference (a) Real Property Unique Identifier - 24001
Page 3 of 17 Reference (a) East Side
Page 4 of 17 Reference (a) West Side
Page 5 of 17 Reference (a) South Side
Page 6 of 17 Reference (a)
Building# 7 Floor Plan
Existing
HVAC
Condenser
Existing Air Handler Above Drop
Ceiling
Thermostat Location
Ballroom
64’
59’
***All measurements are approximate***
Existing HVAC Outdoor Condenser
Page 7 of 17 Reference (a)
MODEL# BWA180C3001A 03/86
SERIAL# S10 198438
COMPR MOT (2) 27 RLA 200-230 V 3 PH 60 HZ
OD MOT (4) 3.8 FLA 200-230 V 1 PH 60 HZ
***All measurements are approximate***
Concrete Pad 7’ x 7’
15’ Ground to the
Roof Line
Existing HVAC Outdoor Condenser
Page 8 of 17 Reference (a)
Area for concrete over to the building
Area to concrete over to the building
Existing Condensate & Refrigerant Lines
Page 9 of 17 Reference (a)
Existing HVAC Air Handler Location
Page 10 of 17 Reference (a)
***All measurements are approximate***
Air Handler Location ABOVE the Drop Ceiling 9’ Floor to Drop Ceiling
MODEL# BWH180B300CA
SERIAL# S180289
03/86
Ballroom View #1
Page 11 of 17 Reference (a)
Ballroom View #2
Page 12 of 17 Reference (a)
Ballroom View #3
Page 13 of 17 Reference (a)
Ballroom View #4
Page 14 of 17 Reference (a)
Ballroom View #5
Page 15 of 17 Reference (a)
Ballroom View #6
Page 16 of 17 Reference (a)
Existing Thermostat
Existing Supply & Return Grille
Page 17 of 17 Reference (a)
Approximately 9 - Supply Diffusers
Approximately 6 - Return Grilles with Filter