L1WC04 - CDRLs A007- Site Acceptance Test Plan.pdf

PDF 596 KB Posted

Attached to
Shot Peen Federal contract opportunity
Solicitation number
FA857121Q0034
Issued by
Department of the Air Force Materiel Command Air Force Sustainment Center

About this file

This Contract Data Requirements List outlines requirements for a Site Acceptance Test Plan deliverable under contract FA857121Q0034. The contractor must submit one electronic copy of the test plan in PDF format to the 402nd Contracting Squadron at Robins Air Force Base within one week of installation completion for government approval. Once approved, the contractor will notify the government point of contact and schedule verification that all requirements have been met. The test plan is for one robotic shot peen system with a capacity to peen 280 and 550 steel shot sizes using a robotic arm in an internal area of at least 5 by 8 by 10 feet. The system will be installed at Building 142 to support the 402nd Aircraft Maintenance Group. This is a small business set-aside commercial supply and incidental services contract for the Air Force Sustainment Center.

View the file

Other files for this federal contract opportunity

Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTRACT DATA REQUIREMENTS LIST

(1 Data Item)

Form Approved OMB No. 0704-0188

The public reporting burden for this collection of information is estimated to average 110 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to the Department of Defense, Executive Services Directorate (0704-0188). Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. Please do not return your form to the above organization. Send completed form to the Government Issuing Contracting Officer for the Contract/PR No. listed in Block E.

A. CONTRACT LINE ITEM NO. B. EXHIBIT C. CATEGORY:

TDP TM OTHER __X__

D. SYSTEM/ITEM E. CONTRACT/PR NO. F. CONTRACTOR

1. DATA ITEM NO. 3. SUBTITLE

4. AUTHORITY (Data Acquisition Document No.)

DI-QCIC-80553

5. CONTRACT REFERENCE

PD paras 5.3

6. REQUIRING OFFICE

402 CMXG/MXDEE

7. DD 250 REQ

NO

9. DIST

STATEMENT

REQUIRED

A

10. FREQUENCY

SEE BLK 16

12. DATE OF 1ST SUBMISSION

SEE BLK 16

14. DISTRIBUTION

a. ADDRESSEE

b. COPIES

8. APP CODE

N/A

11. AS OF DATE

SEE BLK 16

13. DATE OF SUBSEQUENT

SUBMISSION

SEE BLK 16

Draft

Final

Reg Repro

0 0

15. TOTAL 0 1 0

I. APPROVED BY J. DATE

DD Form 1423-1, FEB 2001 PREVIOUS EDITION MAY BE USED Page _ _ of __Pages

18. ESTIMATED

TOTAL PRICE

17. PRICE

GROUP

L1WC04

1 1

G. PREPARED BY H. DATE

16. REMARKS

Block 4: Will be done for the factory acceptance. One electrionic copy. Electronic files shall be in .pdf format.

Blocks 12, 13: .5.3.1 Once installation at Robins AFB is completed and the Government has approved the test plan, the contractor shall notify the Government POC via email and within one (1) week the Government representative(s) shall verify all the requirements in Section 3 have been met.

E-mail Addresses:

chad.steger@us.af.mil james.prince.4@us.af.mil scott.swartz@us.af.mil

SEE BLK 16

HARD COPY

ELECTRONIC 0 1 0

A007

2. TITLE OF DATA ITEM

SITE ACCEPTANCE TEST PLAN

Christine L. Clark 17 May 2021 Christine L. Clark 17 May 2021

File details come from the government source that posted it. Updated .