ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Exhibit_FSolar_Lighting_Install.pdf

PDF 522 KB Posted

Attached to
CONSTRUCT AND INSTALL- Bus Stop Shelters
Solicitation number
ITB# ENG/260740
Issued by
Marion County, Orlando City, Florida

About this file

This is a technical specification document for a solar lighting installation system provided by Urban Solar Corporation for the City of Ocala's bus stop shelter construction project in Florida. The document details the RMS-80F roof-mounted shelter lighting system, which includes an 80-watt nominal solar array, 12-volt direct current system voltage, and a 72-ampere-hour sealed lead acid battery bank. The system incorporates a USC ECM controller with real-time clock capability, an aluminum chassis with polyester powder coat finish, and one 8-watt LED luminaire. The complete system weighs 81 pounds with four batteries installed. The solar panel is secured to the shelter roof using self-tapping screws, with mounting holes to be drilled on-site to match the specific shelter roof configuration. The system includes provisions for optional remote monitoring and control capabilities, with the note that operating profiles are dependent on geographic location and require consultation with Urban Solar for lighting design assistance.

The technical specifications indicate this is proprietary equipment manufactured by Urban Solar Corporation, located in Beaverton, Oregon, with copyright protection dating to 2008. The drawing revision date is November 18, 2018, indicating the specifications reflect current design standards. Installation requirements specify that mounting holes are not pre-drilled and must be prepared on-site by the contractor to ensure proper fit with each shelter's roof structure. The specification document does not address pricing, warranty terms, or performance guarantees but directs contractors to contact Urban Solar directly for assistance with lighting design optimization based on the geographic location and specific operating requirements for each bus stop shelter installation within Ocala and Marion County, Florida.

View the file

Other files

File Type Posted
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Addendum_2.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__2084__Addendum_1.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__8608__2211_NE_14th_ST_Center_for_the_Blind.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters___8608__2211_NE_14th_ST_Center_for_the_Blind.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__4017__250_SE_Watula_Ocala_Citizen_Service_Center_and_City_Hall.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__6017__2703_NE_14th_ST_Career_Source.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Exhibit_B_Price_Proposal.xlsx XLSX spreadsheet
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Exhibit_E_Shleter_Installation_Instructions.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__2084__2730_E_Silver_Springs_Blvd_Marion_County_Veterans_Services_and_Marion_COunty_Offices_Library.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__6034__1813_NE_2nd_ST_Shopping.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__6040__1150_NE_2nd_ST__Ocala_Ritz_Veterans_Village.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__8215__2755_SE_17th_ST_Winter_Woods_Centerfor_Independent_Living.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Exhibit_D_Bench_Install6736.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Exhibit_G__Build_America_Buy_America_Certificate.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__2035__3050_NE_55th_AAve_Silver_Springs_Post_Office.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__4006__3500_E_Silver_Springs_Blvd_PublixTruist_BankMisc_Shops_and_Dining.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__8206__503_SE_25th_Ave_County_Offices_McPherson_Complex.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Exhibit_H__Certification_for_Disclosure_of_Lobbying_Activities.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Exhibit_J__FederalClausesConstruction.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__2002__4699_East_Silver_Springs_Blvd_Six_Gun_Plaza_and_Public_Storage.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__4057__2001_SE_32nd_Ave_Bus_Stop_at_Health_Department.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__4065__351_SW_16th_ST_Hospital.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__5031__3035_SW_27th_Ave_Healthcare_Options.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__8216__2897_SE_Maricamp_RD_HCA_Florida_Maricamp_Emergency.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Exhibit_A__Scope_of_Work.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Exhibit_C_Bus_Stop_Locations_x15.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__Exhibit_I__DBE_Utilization_Form.pdf PDF
ITB_ENG260740_CONSTRUCT_AND_INSTALL_Bus_Stop_Shelters__SAM.gov__DavisBacon_Wage_Determination_1.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B

B

50.3in 1276mm

RMS-80F MODULE

4.5in 114mm

8.8in 222mm

C

SECTION B-B

DETAIL C

SCALE 1 : 6

RMS-80F SOLAR ARRAY

2.6in 65mm

R30in 762mm

R60in 1524mm

59.5in 1510mm

SPECIFICATIONS:

SOLAR ARRAY (W): 80

NOM. SYSTEM VOLTAGE (VDC): 12

MAX. BATTERY BANK (Ah): 72

BATTERY TYPE: SEALED LEAD ACID (SLA)

CONTROLLER: USC ECM C/W REAL TIME CLOCK

CHASSIS MATERIAL: ALUMINUM

CHASSIS COATING: POWDER COAT - POLYESTER

SYSTEM WEIGHT W/ 4 BATTERIES (lbs): 81

TYPICAL INSTALLATION

RMS-80F SOLAR PANEL

NOTES:

1 8W LED LUMINAIRE

2 RMS-80F SOLAR PANEL SECURED TO ROOF W/

SELF TAPPING SCREWS

3 RMS-60F MODULE SECURED WITH

INTERNAL FASTENERS

4 MOUNTING HOLES ARE NOT PRE-DRILLED

HOLES ARE TO BE DRILLED ON SITE TO

MATCH SHELTER ROOF

6 REMOTE SYSTEM CONTROL AND MONITORING

WHEN EQUIPPED WITH OPTIONAL ECM CONNECT

***OPERATING PROFILE DEPENDENT ON

GEOGRAPHIC LOCATION. PLEASE CONTACT

URBAN SOLAR FOR ASSISTANCE WITH LIGHTING

DESIGN.***

A

B

C

D

12345678

B

C

D

12345678

A

Urban Solar 1880 SW Merlo Drive Beaverton, OR, USA 97003

(T) 503-356-5516

TITLEPROPRIETARY

COPYRIGHT © 2008 BY

Urban Solar Corp., Victoria, BC, Canada

ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY

BE REPRODUCED STORED IN A RETRIEVAL SYSTEM, OR

TRANSMITTED IN ANY FORM, WITHOUT THE WRITTEN

PERMISSION OF Urban Solar

DRAWING NO

11080 ARMS80F - ROOF MOUNTED SHELTER LIGHTING SYSTEM

REVISION

18-NOV-2018

DATE

D HANKE

DRAWN BY PAGE

1/1

Sheet1
Drawing View1
Drawing View11
Drawing View45
Drawing View46
Drawing View47
Drawing View48
Section View B-B
Detail View C (1 : 6)
Drawing View51
Drawing View52
Drawing View53