IFB_Drawings.pdf

PDF 14 MB Posted

Attached to
S54 FINISH UPGRADES
Solicitation number
34254102
Issued by
Polk County, Iowa

About this file

IFB Drawings for S54 Finish Upgrades Project – Iowa Army National Guard

This is an Invitation for Bid (IFB) drawing set prepared by I & S Group, Inc. for the Iowa Department of Public Defense on behalf of the Iowa Army National Guard at Camp Dodge, Johnston, Iowa. The project scope encompasses finish upgrades to Building S-54, a 1993 original construction residential (R-1) facility consisting of approximately 22,630 square feet on the first floor and 17,150 square feet on the second floor constructed as Type V-B non-sprinklered buildings with two stories. The work is classified as a Level 1 alteration limited to replacement of interior finishes, plumbing fixtures, toilet partitions, toilet accessories, countertops, ceilings, signage, and related incidental work. The project includes interior repainting work throughout the building, latrine upgrades with ADA-accessible fixtures on the first floor and standard fixtures on the second floor, replacement of select exterior doors, installation of new IAARNG-compliant room identification and wayfinding signage, and restoration of existing areas affected by demolition and construction. The drawing set comprises 36 sheets covering general notes, architectural plans, interior design, plumbing, and electrical systems. Bids are due September 24, 2026 at 1:00 p.m. CDT. The project location is Building S-54, 7105 NW 70th Avenue, Camp Dodge, Johnston, Iowa 50131, with project management under Zach Thompson at the I & S Group Des Moines office (515-243-9143).

The specifications require compliance with UFC 1-200-01 Unified Facilities Criteria (DOD Building Code based on the 2024 International Building Code), the 2024 International Fire Code, 2024 NFPA 101 Life Safety Code, and ADA accessibility standards. The project is subject to all federal Buy American Act (BABA) requirements. Bidders must submit numerical bids through the IMPACS event platform with all required documentation, including the Advertisement, Form of Bid, IFB Drawings, IFB Specifications, and TSB Form. The State of Iowa allows sixty days from invoice submission for payment under Iowa Code 8A.514. No preset line-item structure has been established in the event platform; bidders must structure their proposals based on the detailed drawings and specifications provided. Bidders are responsible for verifying existing field conditions, coordinating with multiple trades, protecting existing construction to remain, and managing temporary enclosures to separate construction from occupied areas. The issuing officer is Philip Payton, Iowa Department of Public Defense, reachable at 515-975-6211 or philip.payton@dpd.iowa.gov.

View the file

Other files

File Type Posted
Specs.pdf PDF
Drawings.pdf PDF
Advertisement for Bid.pdf PDF
1443205-event.pdf PDF
General Conditions (AIA Document A201-2007).html HTML file
Advertisement Rev1.pdf PDF
TSB_Form (12).pdf PDF
IFB_Specifications Rev1.pdf PDF
Performance and Payment Bond (AIA Document A312-2010).html HTML file
Application and Certificate for Payment (AIA Documents G702 and G703-1992).html HTML file
Form_of_Bid Rev1.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B-53

W420A

S-04A

S-49

W-42

B-61A

B-58A

B-62A

B-62B

S-47

S-73

A-29

S-00

S-103

S-104

S-105

AD-8

S-21A

S-02B

A-09

B-01

A-10A

L-03

W-39Q

W-09

S-57

B-71

S-31

T-06D

W-11

S-30S

W-34

S-28

S-16

B-02

A-17

C-03

A-07

A-28Q

B-25

S-11C

M-07

B-69

B-63

B-67

S-08BS-14

B-03

W-22

B-06

C-01

M-03

AD-06

S-55

S-42

S-04

S-13

S-71

S-40

L-04

W-38Q

W-37Q

S-01

S-021A

M-12

M-01

AD-01

W-05

W-04

S-37

S-34

WP-3

T-33

S-11I

DF-4

S-16I

A-31

B-34

L-11

B-10

S-14C

A-12Q

A-13

A-46

T-06F

B-47

S-53

W-26

S-52

L-10

W-20

S-20

T-06C

S-44

B-03A

S-301

B-39

W-08

B-70

DF-1

S-04H

S-06

AD-02

AD-05

W-12H0

S-43

RT-2

B-18

B-17

S-39

L-07

S-23A

B-33

B-32

B-46

B-55

B-20

DF-2

W-12H1

B-42

B-04

A-21

B-07

B-49

S-29

S-54

A-01

S-50

W-46

A-05

A-04

T-06H

B-37

S-36

W-33

S-32

M-13

W-32

W-36Q

W-03

S-34H

B-57

S-03A

S-12

B-61

A-06A

S-11A

B-30

DF-3

S-101

T-601

B-26

B-35

B-62

B-68

W-12A

W-48

L-05

B-12

PT-01

B-48

T-21

S-60H

S-63

L-09

A-41

B-36

W-40Q L-02

A-06

B-22

DF-5

B-76

B-58

T-06E

B-75

S-05

S-02H

S-16A

B-19

S-23

A-18

A-08

S-21

M-06

B-15

L-06

B-29

W-40

A-25

M-15

B-45

B-51

B-44

S-02

W-41

M-09

B-08

T-06G

PT-06

B-13

A-42

RT-4

T-2702S-17

S-38A

S-302

W-10

W-46H

S-56

C-02

W-46A

S-02A

AD-04

A-22

A-26Q

W-02

W-01

W-00

S-30A

A-62

S-28H

S-38

A-34

M-11

B-27

S-102

B-65

M-08

T-09

W-25

B-43

S-16C

W-06

B-60

B-14

B-11

W-21

B-09

S-59

S-13C

T-06B

S-70

B-40

B-38

W-12

W-47

S-33

S-07

AD-03

A-63

A-23

S-03

B-16

S-12C

L-08

B-28

T-2701

B-59

W-27

W-35

B-05

S-60

A-01A

B-24

B-23

C-04

W-18Q

W-19

S-72

W-32Q

W-14

S-35

S-30H

S-30

S-34A

S-34P

B-50

A-15

S-23T

A-30

AD-07

B-64

B-66

S-08A

B-31

B-21

B-41

A-20Q

A-40

A-02

A-03Q

M-04 M-05

M-10

S-11

S-58

W-07

B-56

S-51

W-15

W-16

T-06A

3259E

2198B 3209C

3203D

3165E

3535A

3583A

3586A

3586B

5541A

2262A

3824A

2187D

3259A

3205A3203

3203B

3267B

3259C

3165C

3203A

4665A

2187F

2187C

4640A

2326A

4410B

3850B

4410A

3729A

2187G

2479A

2289A

3259B

4410C

1350A

2187E

2375A

3165B

3753A

2187H

3850C

2185A2183A

2326B

2467A

3449A

3447A

3802A

3165A

3209A

2187B

3257A

3850A

2447A

2297A

3267A

3800A

2198A

2187A

PROJECT LOCATION

BLDG: S-54

SITE ENTRY

NW 70TH AVE

PROJECT LOCATION

LOCATION MAP

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

PROJECT INDEX:

OWNER: PROJECT ADDRESS: MANAGING OFFICE:

I & S GROUP, INC. (ISG)

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:12:46 PM

G1-10

TITLE SHEET,

SHEET INDEX,

PROJECT

GENERAL NOTES

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

S-54

7105 NW 70TH AVE

CAMP DODGE, JOHNSTON, IOWA

50131

PROJECT MANAGER: ZACH THOMPSON

EMAIL: ZACH.THOMPSON@ISGINC.COM

IOWA ARMY NATIONAL GUARD

7105 NW 70TH AVE

JOHNSTON, IOWA 50131

CAMP DODGE, JOHNSTON, IOWA

G1-10 TITLE SHEET, SHEET INDEX, PROJECT GENERAL NOTES

IOWA ARMY NATIONAL GUARD S54 FINISH UPGRADES

200 34920 G1-10

ISG PROJECT # 26-34920

PROJECT GENERAL NOTES

A. ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS, WHICH INCLUDE,

BUT ARE NOT LIMITED TO, THE OWNER - CONTRACTOR AGREEMENT, THE

PROJECT MANUAL (WHICH INCLUDES GENERAL AND SUPPLEMENTARY

CONDITIONS AND SPECIFICATIONS), DRAWINGS OF ALL DISCIPLINES AND ALL

ADDENDA, MODIFICATIONS AND CLARIFICATIONS ISSUED BY THE ARCHITECT /

ENGINEER.

B. CONTRACT DOCUMENTS SHALL BE ISSUED TO ALL SUBCONTRACTORS BY THE

GENERAL CONTRACTOR IN COMPLETE SETS IN ORDER TO ACHIEVE THE FULL

EXTENT AND COMPLETE COORDINATION OF ALL WORK. CONTRACTOR IS

RESPONSIBLE FOR COORDINATING AND CORRELATING QUANTITIES AND

DIMENSIONS.

C. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. NOTIFY

ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING

INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.

D. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. NOTIFY ARCHITECT /

ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION

OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.

E. DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE PROFILES AND TYPE

OF DETAILING REQUIRED THROUGHOUT THE WORK. DETAILS NOT SHOWN ARE

SIMILAR IN CHARACTER TO DETAILS SHOWN. WHERE SPECIFIC DIMENSIONS,

DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, NOTIFY ARCHITECT /

ENGINEER BEFORE PROCEEDING WITH THE WORK.

F. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED,

INSTALLED, CONNECTED, ERECTED, CLEANED AND CONDITIONED ACCORDING TO

MANUFACTURERS' INSTRUCTIONS. IN CASE OF DISCREPANCIES BETWEEN

MANUFACTURERS' INSTRUCTIONS AND THE CONTRACT DOCUMENTS, NOTIFY

ARCHITECT / ENGINEER BEFORE PROCEEDING WITH THE WORK.

G. LARGE-SCALE, MORE SPECIFIC DETAILS TAKE PRECEDENCE OVER

SMALLER-SCALE, LESS SPECIFIC DETAILS AND INFORMATION. MORE STRINGENT

REQUIREMENTS FOR CODE, PRODUCTS AND INSTALLATION TAKE PRECEDENCE

OVER LESS STRINGENT REQUIREMENTS. NOTIFY ARCHITECT/ENGINEER OF ANY

DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION OR CLARIFICATION

BEFORE PROCEEDING WITH THE WORK.

H. PROVIDE CONTINUOUS SEALANT AROUND ALL MATERIALS AT ALL INTERIOR AND

EXTERIOR WALL PENETRATIONS. REFER TO SPECIFICATIONS FOR APPROPRIATE

SEALANT.

I. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER

TO AVOID GALVANIC CORROSION.

J. SEAL ALL OPENINGS IN WALLS, FLOORS, CEILINGS, AND ROOFS, AROUND DUCTS,

PIPES, VENTS, TRAPS, CONDUIT AND ALL OTHER PENETRATIONS WITH FIRE

STOPPING AS SPECIFIED AND REQUIRED BY CODES. IF FIRE STOPPING IS NOT

REQUIRED AT PENETRATIONS PER CODE, SEAL WITH CONTINUOUS SEALANT.

K. PROVIDE TEMPORARY WALLS, ENCLOSURES, DUST SHIELDS AND WALK-OFF MATS

AS REQUIRED TO SEPARATE DEMOLITION AND CONSTRUCTION FROM EXISTING

BUILDING.

L. PROVIDE BRACING AND SHORING AS REQUIRED TO PROTECT EXISTING

STRUCTURE TO REMAIN. PROVIDE SECURE AND WEATHERPROOF ENCLOSURE OF

TEMPORARY OPENINGS IN EXTERIOR WALLS. PROTECT ALL BUILDING

COMPONENTS FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION.

M. RESTORE ALL EXISTING AREAS AFFECTED BY DEMOLITION AND RELATED NEW

CONSTRUCTION TO THEIR ORIGINAL CONDITION, INCLUDING BUT NOT LIMITED TO

WALLS, FLOORS, AND CEILINGS AND THEIR ASSOCIATED FINISHES.

N. PROVIDE SOLID WALL BACKING WITH METAL OR FIRE-RETARDANT WOOD

BLOCKING BEHIND DOOR HARDWARE SUCH AS WALL STOPS, BUMPERS, HOLD

OPENS, ETC. AND AT ALL ITEMS REQUIRING FASTENING THROUGH GYP BD. TO

BLOCKING

O. RENDERED IMAGES MAY NOT BE AN ACCURATE REPRESENTATION OF BUILDING

CONDITIONS, REFER TO PLANS AND DETAILS CONTAINED WITHIN FOR SCOPE OF

WORK.

SHEET INDEX

SHEET # SHEET TITLE

GENERAL

G1-10 TITLE SHEET, SHEET INDEX, PROJECT GENERAL NOTES

G1-12 MOUNTING HEIGHTS, ABBREVIATIONS AND SYMBOLS, HORIZONTAL

ASSEMBLIES

G2-20 FIRST AND SECOND FLOOR CODE PLANS AND CODE DATA

ARCHITECTURAL

A1-11 FIRST FLOOR DEMOLITION PLAN - OVERALL

A1-11A FIRST FLOOR DEMOLITION PLAN - AREA A

A1-11B FIRST AND SECOND FLOOR DEMOLITION PLAN - AREA B

A1-12 SECOND FLOOR DEMOLITION PLAN - OVERALL

A1-12A SECOND FLOOR DEMOLITION PLAN - AREA A

A1-13 FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL

A1-13A FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A

A1-13B FIRST AND SECOND FLOOR REFLECTED CEILING DEMOLITION PLANS -

AREA B

A1-14 SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL

A1-14A SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A

A1-21 FIRST FLOOR PLAN - OVERALL

A1-21A FIRST FLOOR PLAN - AREA A & DOOR SCHEDULE, DOOR AND FRAME

TYPES

A1-21B FIRST AND SECOND FLOOR PLAN - AREA B

A1-22 SECOND FLOOR PLAN - OVERALL

A1-22A SECOND FLOOR PLAN - AREA A

A1-31 FIRST FLOOR REFLECTED CEILING PLAN - OVERALL

A1-31A FIRST FLOOR REFLECTED CEILING PLAN - AREA A AND CEILING DETAILS

A1-31B FIRST AND SECOND FLOOR REFLECTED CEILING PLANS - AREA B

A1-32 SECOND FLOOR REFLECTED CEILING PLAN - OVERALL

A1-32A SECOND FLOOR REFLECTED CEILING PLAN - AREA A

A5-11 ENLARGED FLOOR PLANS

INTERIOR DESIGN

I1-21 FIRST FLOOR FINISH PLAN - OVERALL

I1-21A FIRST FLOOR FINISH PLAN - AREA A

I1-21B FIRST AND SECOND FLOOR FINISH PLAN - AREA B

I1-22 SECOND FLOOR FINISH PLAN - OVERALL

I1-22A SECOND FLOOR FINISH PLAN - AREA A

I1-41 FIRST FLOOR SIGNAGE PLAN - OVERALL

I1-41A FIRST FLOOR SIGNAGE PLAN - AREA A

I1-41B FIRST AND SECOND FLOOR SIGNAGE PLAN - AREA B

I1-42 SECOND FLOOR SIGNAGE PLAN - OVERALL

I1-42A SECOND FLOOR SIGNAGE PLAN - AREA A

I4-11 FINISH LEGENDS, SCHEDULES, AND DETAILS

PLUMBING

P2-12 FIRST FLOOR PLUMBING PLAN

P2-13 SECOND FLOOR PLUMBING PLAN

ELECTRICAL

E2-11A FIRST FLOOR POWER AND SYSTEMS PLAN - AREA A

E2-12A SECOND FLOOR POWER AND SYSTEMS PLAN - AREA A

E5-11 ELECTRICAL SYMBOLS, PANELBOARDS SCHEDULES

217 EAST 2ND STREET

SUITE 110

DES MOINES, IOWA 50309

PHONE: 515.243.9143

DES MOINES OFFICE

1" = 400'-0"2

CAMP DODGE VICINITY MAP

ESSIO

FO

NAL

A R

C H

IT

E

C

R

P D

E S

N E

CI

L

T

SIGNATURE

PRINTED SIGNATURE

DATE

LICENSE NUMBER LICENSE RENEWAL DATE

SEAL

WIO A

SHEETS COVERED BY THIS SEAL:

I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL

SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME

OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE

CHARGE. I AM A DULY LICENSED ARCHITECT UNDER THE

LAWS OF THE STATE OF IOWA.

ADAM W.

PULS

P23206 P23206 12/31/27

ADAM W. PULS

09/08/26

ESSIO

FO

NAL

A R

C H

IT

E

C

R

P D

E S

N E

CI

L

T

SIGNATURE

PRINTED SIGNATURE

DATE

LICENSE NUMBER LICENSE RENEWAL DATE

SEAL

WIO A

SHEETS COVERED BY THIS SEAL:

I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL

SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME

OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE

CHARGE. I AM A DULY LICENSED ARCHITECT UNDER THE

LAWS OF THE STATE OF IOWA.

GLADYS

PETERSEN

ARC08590 ARC08590 06/30/27

GLADYS PETERSEN

09/08/26

ESSIO

FO

NAL

A R

C H

IT

E

C

R

P D

E S

N E

CI

L

T

SIGNATURE

PRINTED SIGNATURE

DATE

LICENSE NUMBER LICENSE RENEWAL DATE

SEAL

WIO A

SHEETS COVERED BY THIS SEAL:

I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL

SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME

OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE

CHARGE. I AM A DULY LICENSED ARCHITECT UNDER THE

LAWS OF THE STATE OF IOWA.

CASEY G.

LARSEN

P26594 P26594 12/31/26

CASEY G. LARSEN

09/08/26

G1-10

G1-12

G2-20

A1-11

A1-11A

A1-11B

A1-12

A1-12A

A1-13

A1-13A

A1-13B

A1-14

A1-14A

A1-21

A1-21A

A1-21B

A1-22

A1-22A

A1-31

A1-31A

A1-31B

A1-32

A1-32A

A5-11

I1-21

I1-21A

I1-21B

I1-22

I1-22A

I1-41

I1-41A

I1-41B

I1-42

I1-42A

I4-11

E2-11A

E2-12A

E5-11

1/2" = 1'-0"1

LOCATION MAP - ENLARGED

P2-12

P2-13

REVISION SCHEDULE

DATE DESCRIPTION BY

*U R

H

A D

A C

O M

P L

IA

N T

O N

L Y

M A

X

FLUSH VALVE

RIM

MOUNTING HEIGHTS AND STANDARDS

AMBULATORY STALL

PLAN VIEW

(GRAB BARS EA SIDE,

REFER TO WATER CLOSET -

SIDE WALL DETAIL

FOR CONFIGURATION)

36" CLEAR

M

IN

C L E

A R

WATER CLOSET

REAR WALL

WATER CLOSET

SIDE WALL

24" MIN 12" MIN

*WCC

*G B

H

24" MIN

42" MAX

7"-9"

M

IN

/2

M

IN

*G B

H

*V B

H

M

IN

12" MAX 42" MIN

*VBC

54" MIN

OPERABLE PARTS OF

DISPENSERS AND SANITARY

PRODUCT RECEPTACLES

SHALL BE LOCATED WITHIN

HATCHED AREA (ONLY

APPLICABLE FOR ADULT

RESTROOMS)

60" CLEAR FLOOR SPACE

*W C

S 4

M A

X

*T P

H

SANITARY PRODUCT

RECEPTACLE

ELECTRIC HAND

DRYER

TOP AT 2" MIN BELOW

HORIZONTAL GRAB BAR;

OPERABLE PARTS

WITHIN 12" MIN AND 40"

MAX FROM REAR WALL

FIXTURE CLEARANCES

DESCRIPTION

*GBH GRAB BAR HEIGHT

*TPH TOILET TISSUE DISPENSER HEIGHT

*WCC WATER CLOSET CENTER LINE

*WCS WATER CLOSET SEAT HEIGHT

*TSH TOP OF SINK OR COUNTER HEIGHT

*KCH KNEE CLEARANCE HEIGHT

*VBH VERTICAL GRAB BAR HEIGHT

*VBC VERTICAL GRAB BAR CENTERLINE

*HDH HIGH DRINKING FOUNTAIN SPOUT HEIGHT

*LDH LOW DRINKING FOUNTAIN SPOUT HEIGHT

*DSD DRINKING FOUNTAIN SPOUT DEPTH

FIXTURE GROUPS

*URH URINAL RIM HEIGHT

ADULTS (>12 YR)

33" - 36"

18" - 48"

17" - 18"

17" - 19"

34"

27"

39" - 41"

39" - 41"

38" - 43"

36"

5"

R1

ACCESSIBLE

NA

18" - 48"

16" - 18"

17" - 19"

34"

27"

NA

NA

38" - 43"

36"

5"

STANDARD

S

17" 24"

URINAL (ADA COMPLIANT ONLY)

WHEN TWO OR MORE URINALS ARE

SHOWN, MOUNT ONLY ONE AT ADA

COMPLIANT HEIGHT AND OTHERS

AT STANDARD RIM HEIGHT

REAR WALL GRAB BAR

OMITTED WITHIN

AMBULATORY STALLS

A

32" CLEAR MIN.

DOOR MUST

SWING OUT

M

IN

ADA COMPLIANT SIGNAGE

MULTIPLE LINE

ADA SIGNAGE

B O

T T

O M

L

IN

E O

F B

R A

IL

L E

M

IN

T

O B

O T

T O

M O

F

O F

R A

IS

E

D C

H A

R A

C T

E R

S

M

A X

T O

B O

T T

O M

O F

T O

P L

IN

E

O P

E R

A B

L E

P A

R T

T

O H

IG

H

E S

T

MATERIALS KEY

WOOD

SAND

STEEL

GRAVEL

GYPSUM BOARD

PLYWOOD

CONCRETE (SECTION)

GRANULAR FILL

EARTH

CMU (SECTION)

BATT INSULATION

BRICK

RIGID INSULATION

OR SHEATHING

SYNTHETIC STUCCO

TAGS AND SYMBOLS

SECTION

INTERIOR /

EXTERIOR

ELEVATION

DETAIL CALLOUT

AREA OF DETAIL

LEVEL 1

100'-0"

ELEVATION

DRAWING

TITLE

ABBREVIATIONS

SPRAY IN PLACE

INSULATION

VIEW NAME

1/8" = 1'-0"

A1-11

A1-11

SECTION NUMBER

SHEET NUMBER

A1-11

ELEVATION NUMBER

SHEET NUMBER

WELD SYMBOL

1/4 2-12

NOTES

COLUMN TYPE

CAP PLATE

BASE PLATE

COLUMN

??? 100' - 0"

SPOT

ELEVATION

DESCRIPTION

ELEVATION

DENOTES

ANNOTATION IS

REFERENCING

ANOTHER VIEW

*REFER TO ANSI FOR WELD

SYMBOL STANDARDS

C#

CP#

BP#

MOMENT

CONNECTION

SYMBOL

FOOTING STEP

BEAM SPLICE

SYMBOL

PIER TYPE

FOUNDATION

WALL TYPE

FOOTING TYPE

*REFER TO MOMENT

CONNECTION DETAILS

"S

DIRECTION OF

INSTALL

M1

P1

F1

FDN1

LEDGE STEP

FOOTING &

LEDGE STEP

NEW

CONSTRUCTION

GRIDS

EXISTING

CONSTRUCTION

GRIDS

1 1

B

A

WINDOW TYPE

EQUIPMENT TYPE A

MATERIAL TYPE

CASEWORK

TAG

FIN#

AL15

CDS

W#

H# D#

MOD LINE 1

MOD LINE 2

CDS CATALOG NUMBER FROM

NORTH AMERICAN

ARCHITECTURAL WOODWORK

STANDARDS (NAAWS)

(IF "M" IS INCLUDED SEE NOTE

BELOW FOR DESCRIPTION OF

MODIFICATION)

NOMINAL DEPTH

NOMINAL HEIGHT

NOMINAL WIDTH

DESCRIPTION OF MODIFICATION

FROM CDS CATALOG

FRAMING

TAG

18K W8X24 100'-0" (25) C=1" 15K

REACTION, TYPICAL

BOTH ENDS

MEMBER SIZE

NUMBER OF STUDS

CAMBER SIZE

WALL TYPE M12

SLAB TYPE SL#-9A

KEYNOTE TAG 3

DOOR NUMBERS 101

F1CEILING, FLOOR, OR

ROOF ASSEMBLY TYPE

ALT #

1/ A1-11

ALTERNATE

CALLOUT

DETAIL AND

SHEET NUMBER

ALTERNATE

NUMBER

MEMBER ELEVATION

SHEAR WALL

TAG

TYPE #

TYPE #

SHEAR WALL TAG

REACTION VALUE,

TYPICAL BOTH ENDS

HOLD DOWN TYPE,

TYPICAL BOTH ENDS

FLOOR

MATERIAL TYPE

F FIN#

SW#

SHEET NUMBER

DETAIL NUMBER

TRACK

ACOUSTICAL CEILING

TILE, REFER TO CEILING

PLANS AND INTERIOR

FINISH SCHEDULE

HANGER WIRE

DECK/ PLANK

ABOVE

SECTION

TRACK

ACOUSTICAL CEILING

TILE, REFER TO CEILING

PLANS AND INTERIOR

FINISH SCHEDULE

HANGER WIRE

DECK/ PLANK

ABOVE

SECTION

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:12:47 PM

G1-12

MOUNTING

HEIGHTS,

ABBREVIATIONS

AND SYMBOLS,

HORIZONTAL

ASSEMBLIES

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

G1-12 MOUNTING HEIGHTS, ABBREVIATIONS AND SYMBOLS, HORIZONTAL ASSEMBLIES

200 34920 G1-12

# POUND OR NUMBER

@ AT

ACP ACOUSTICAL CEILING PANEL

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADD ADDENDUM

ADDL ADDITIONAL

ADJ ADJACENT

AFF ABOVE FINISH FLOOR

AFG ABOVE FINISHED GRADE

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATELY

ARCH ARCHITECTURAL

AWP ACOUSTICAL WALL PANEL

B BASE

BD BOARD

BL BROADLOOM CARPET

BLDG BUILDING

BO BOTTOM OF OR BY OWNER

BR BRICK

BRG BEARING

BSMT BASEMENT

C CONDUIT

CFS COLD FORMED STEEL

CG CORNER GUARD

CI CONTINUOUS INSULATION

CIP CAST IN PLACE

CJ CONTROL JOINT OR CONSTRUCTION JOINT

CL CENTERLINE

CLG CEILING

CLR CLEAR

CM CORRUGATED METAL

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

CONC CONCRETE

CONF CONFERENCE

CONT CONTINUOUS

CPT CARPET

CR CHAIR RAIL

CRK CORK

CT TILE

CURT PRIVACY CURTAIN

CY CUBIC YARD

DEMO DEMOLITION

DF DRINKING FOUNTAIN

DH DOOR HOLDER (MAGNETIC)

DIA DIAMETER

DLS DIMENSIONAL LETTER SIGNAGE

EA EACH

EC ELECTRICAL CONTRACTOR

EF EXHAUST FAN

EIFS EXTERIOR INSULATION FINISH SYSTEM

ELEC ELECTRICAL

ELEV ELEVATION

EMERG EMERGENCY

ENCL ENCLOSURE

EPDM ETHYLENE PROPYLENE DIENE MONOMER

EPX EPOXY

EQ EQUAL

EQUIP EQUIPMENT

ETC ETCETERA

EWC ELECTRIC WATER COOLER

EX EXISTING

EXP EXPANSION, EXPOSED

EXT EXTERIOR

F&I FURNISH AND INSTALL

FA FRESH AIR

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FBO FURNISHED BY OTHERS

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FLOOR FINISH

FFE FINISHED FLOOR ELEVATION

FRP FIBERGLASS REINFORCED PLASTIC

FRZ FREEZER

FS FLOOR SINK

FT FOOT OR FEET

FTG FOOTING

GA GAUGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPT

GL GLAZING

GND GROUND

GYP GYPSUM

HD HUB DRAIN

HDG HOT DIP GALVANIZED

HDW HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HSA HEADED STUD ANCHOR

HSS HOLLOW STRUCTURAL SECTION

HT HEIGHT

HVAC HEATING VENTILATION AND AIR CONDITIONING

ID INSIDE DIAMETER

IG ISOLATED GROUND

IMP INSULATED METAL PANEL

INFO INFORMATION

INP IN-PLACE

INSUL INSULATION

INT INTERIOR

J JUNCTION BOX

JAN JANITOR

JBE JOIST BEARING ELEVATION

JST JOIST

KES KITCHEN EQUIPMENT SUPPLIER

kW KILOWATT

LAV LAVATORY

LB POUND

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LN LINEAR

LVT LUXURY VINYL TILE

MATL MATERIAL

MAX MAXIMUM

MB MARKER BOARD

MECH MECHANICAL

MEP MECHANICAL , ELECTRICAL, PLUMBING

MEZZ MEZZANINE

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

MULL MULLION

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OC ON CENTER

OCEW ON CENTER EACH WAY

OD OUTSIDE DIAMETER

OH OVERHEAD

OHD OVERHEAD DOOR

OL OVERALL LENGTH

OPNG OPENING

ORD OVERFLOW ROOF DRAIN

OSB ORIENTED STRAND BOARD

PC PHOTO CELL, POLISHED CONCRETE

PLAM PLASTIC LAMINATE

PLWP PLASTIC LAMINATE WALL PANEL

PNT PAINT

PNT-#E EPOXY PAINT

POLYETH POLYETHYLENE

POLYISO POLYISOCYANURATE

PRV POWER ROOF VENTILATOR

PVC POLYVINYL CHLORIDE

QT QUARRY TILE

QTZ QUARTZ

RA RETURN AIR

RB RESILIENT BASE

RBR RUBBER

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REF REFRIGERATOR

REINF REINFORCED

REQD REQUIRED

RES RESINOUS FLOOR

REV REVISION / REVISED

RM ROOM

RO ROUGH OPENING

ROW / R/W RIGHT OF WAY

RP RESIN PANEL

RTE REFER TO ELEVATION

RTU ROOF TOP UNIT

SA SUPPLY AIR

SC SEALED CONCRETE

SF SQUARE FOOT

SIM SIMILAR

SM SURFACE MOUNTED

SPEC SPECIFICATION

SS SOLID SURFACE

SSTL STAINLESS STEEL

STD STANDARD

STN STONE

STOR STORAGE

SUSP SUSPENDED

SV SHEET VINYL

SY SQUARE YARDS

T&G TONGUE AND GROOVE

T&P TEMPERATURE AND PRESSURE

TB TACK BOARD

TBD TO BE DETERMINED

TD TRENCH DRAIN

TEC TECTUM

TEL TELEPHONE

TEMP TEMPERATURE

TER TERRAZZO

TO TOP OF

TOF TOP OF FOOTING

TOL TOP OF LEDGE

TOS TOP OF STEEL

TOW TOP OF WALL

TR TAMPER RESISTANT

TS TUBE STEEL / THRESHOLD / TRANSITION STRIP

TV TELEVISION

TYP TYPICAL

UG UNDERGROUND

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

VCT VINYL COMPOSITE TILE

VERT VERTICAL

VEST VESTIBULE

VF VINYL FLOOR

VIF VERIFY IN FIELD

VTR VENT THROUGH ROOF

VWP VENEER WALL PANEL

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WCG WALL COVERING

WD WOOD

WF WINDOW FILM

WG WALL GUARD

WH WALL HYDRANT

WHTR WATER HEATER

WP WEATHERPROOF

WT WINDOW TREATMENT

WWF WELDED WIRE FABRIC

XFMR TRANSFORMER

NOT TO SCALE

CEILING ASSEMBLY ACT-1

NOT TO SCALE

CEILING ASSEMBLY ACT-2

D

D

D D

W W

W W

W

D D

D

D D

D W

W W

W W

W

UP

UP

UP

WWWWWW

W W

W W

D D

D D

D D D D D D D

DN

DN

DN

DN

CODE DATA PLAN KEY

KB

EXIT

FIRE EXTINGUISHER

(NO WORK, EXISTING FE'S TO REMAIN)

FIRE EXTINGUISHER CABINET

(NO WORK, EXISTING FEC'S TO REMAIN)

FRONTAGE DISTANCE

KNOX BOX

FE

FEC

FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE

BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL

REQUIRED TO HAVE PROTECTED OPENINGS OR

PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY

IDENTIFIED WITH SIGNS OR STENCILING. SUCH

IDENTIFICATION SHALL:

1. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-

CEILING OR ATTIC SPACES

2. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL

AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED

HORIZONTALLY ALONG THE WALL OR PARTITION, AND

3. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT

WITH A MINIMUM 3/8" STROKE IN A CONTRASTING COLOR

INCORPORATING THE SUGGESTED WORDING "FIRE

AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS" OR

OTHER SIMILAR WORDING.

FIRE DEPARTMENT

CONNECTION

AED AUTOMATED EXTERNAL DEFIBRILLATOR

GENERAL CODE DATA

ADOPTED BUILDING CODES

UFC 1-200-01 UNIFIED FACILITIES CRITERIA (UFC) DEPARTMENT OF

DEFENSE BUILDING CODE

(BASED ON 2024 INTERNATIONAL BUILDING CODE)

2024 INTERNATIONAL BUILDING CODE AS ADOPTED BY IOWA

ADMINISTRATIVE RULE CHAPTERS 481-280 AND 481-301

2024 INTERNATIONAL FIRE CODE AS ADOPTED BY IOWA ADMINISTRATIVE

CHAPTER 481-280

2012 INTERNATIONAL ENERGY CONSERVATION CODE AS ADOPTED BY

IOWA ADMINISTRATIVE RULE CHAPTER 481-301

2012 NFPA 101 LIFE SAFETY CODE AS ADOPTED BY IOWA ADMINISTRATIVE

RULE CHAPTER 481-280

SMOKE ALARMS/DETECTORS AS ADOPTED BY IOWA ADMINISTRATIVE

RULE CHAPTER 481-280

CARBON MONOXIDE ALARMS AS ADOPTED BY IOWA ADMINISTRATIVE

RULE CHAPTER 481-280

STATE MECHANICAL CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC

HEALTH IOWA ADMINISTRATIVE RULE CHAPTER 481-426

STATE PLUMBING CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC

HEALTH IOWA ADMINISTRATIVE RULE CHAPTER 481-425

STATE ELECTRICAL CODE AS ADOPTED BY THE STATE ELECTRICAL

LICENSING BOARD IOWA ADMINISTRATIVE RULE CHAPTER 481-404

ACCESSIBILITY CODES AND STANDARDS

UFC 1-200-01 UNIFIED FACILITIES CRITERIA (UFC) DEPARTMENT OF

DEFENSE BUILDING CODE

(BASED ON 2024 INTERNATIONAL BUILDING CODE)

ABA STANDARDS AND DEPARTMENT OF DEFENSE POLICY MEMORANDUM

ACCESSIBILITY STANDARDS FOR DEPARTMENT OF DEFENSE FACILITIES

2010 AMERICANS WITH DISABILITIES ACT AS ADOPTED BY IOWA

ADMINISTRATIVE RULE CHAPTER 481-301

OCCUPANCY CLASSIFICATION AND USE

RESIDENTIAL R-1

FIRE PROTECTION SYSTEMS

NONSPRINKLERED

CONSTRUCTION TYPE

TYPE VB

EXISTING BUILDING ALTERATION: LEVEL 1 ALTERNATION

WORK IS LIMITED TO REPLACEMENT OF INTERIOR FINISHES, PLUMBING

FIXTURES, TOILET PARTITIONS, TOILET ACCESSORIES, COUNTERTOPS,

CEILING, SIGNAGE, AND RELATED INCIDENTAL WORK. NO CHANGE IN

OCCUPANCY CLASSIFICATION, OCCUPANT LOAD, BUILDING AREA,

BUILDING HEIGHT, MEANS OF EGRESS, OR FIRE-RESISTANCE-RATED

CONSTRUCTION IS PROPOSED. WORK IS CLASSIFIED AS A LEVEL 1

ALTERATION UNDER THE 2024 INTERNATIONAL EXISTING BUILDING CODE.

EXISTING LAWFUL CONDITIONS ARE PERMITTED TO REMAIN EXCEPT

WHERE SPECIFICALLY REQUIRED BY THE IEBC. NEW MATERIALS AND

ALTERED ELEMENTS SHALL COMPLY WITH THE CURRENTLY ADOPTED

CODES AND ACCESSIBILITY STANDARDS WITHIN THE SCOPE OF WORK.

3078 SF

DINING

858 SF

KITCHEN

99 SF

164E

STORAGE

KITCHEN

74 SF

164D

STORAGE

KITCHEN

33 SF

ENTRY

100 SF

OFFICE

30 SF

LATRINE

45 SF

ENTRY

122 SF

ELECTRICAL

141 SF

SCULLERY

634 SF

MECHANICAL

31 SF

JANITORIAL

320 SF

STORAGE

SUPPLY

515 SF

OFFICE

104 SF

OFFICE

331 SF

LAUNDRY

605 SF

LATRINE A

464 SF

LATRINE B

46 SF

JANITORIAL

1282 SF

CORRIDOR

211 SF

CORRIDOR

2146 SF

BARRACKS

A

2147 SF

BARRACKS

B

48 SF

ENTRY

1014 SF

DAY ROOM

48 SF

ENTRY

280 SF

LAUNDRY

555 SF

LATRINE D 376 SF

LATRINE C

25 SF

JANITORIAL

157 SF

CORRIDOR

2155 SF

BARRACKS

C

2125 SF

BARRACKS

D

74 SF

114A

STAIRS

74 SF

114B

STAIRS

>30 FT ALL

SIDES, TYP

MECHANICAL

LATRINE

MECHANICAL

VESTIBULE

CORRIDOR

VESTIBULE

BARRACK

BARRACK

703 SF

MECHANICAL

700 SF

LAUNDRY

2153 SF

BARRACKS

H

2142 SF

BARRACKS

G

448 SF

LATRINE H

2131 SF

BARRACKS

E

2165 SF

BARRACKS

F

379 SF

LATRINE G

468 SF

LATRINE F

493 SF

LATRINE E

201 SF

CORRIDOR

179 SF

CORRIDOR

540 SF

CORRIDOR

24 SF

JANITORIAL

46 SF

JANITORIAL

132 SF

CORRIDOR

172 SF

CORRIDOR

210 SF

CORRIDOR

254 SF

CORRIDOR

224 SF

CORRIDOR

287 SF

CORRIDOR

74 SF

114A

STAIRS

74 SF

114B

STAIRS

MECHANICAL

LATRINE

MECHANICAL

VESTIBULE

CORRIDOR

VESTIBULE

BARRACK

BARRACK

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

EXISTING RATED EXTERIOR

CONSTRUCTION TO REMAIN

EXISTING RATED INTERIOR

CONSTRUCTION TO REMAIN

CONTRACTOR TO VERIFY EXISTING RATED WALL

CONSTRUCTION IN FIELD AND REPORT ANY

DISCREPANCIES TO THE PROJECT ARCHITECT.

FLOOR PLAN LEGEND

SHADED REGION INDICATES AREA OF PLANS THAT

ARE NOT INCLUDED IN SCOPE OF WORK.

BUILDING A: 2026 FINISHES AND REPAIRS

• FINISH UPGRADES THROUGHOUT BUILDING

• REUSE EXISTING DUCTWORK

• MAINTAIN EXISTING RATED PARTITIONS BUILDING A: 1993 ORIGINAL CONSTRUCTION

GROUP R-1

TYPE V-B CONSTRUCTION

NON-SPRINKLED

2 STORIES

1ST FLOOR: 22,630 SF

2ND FLOOR: 17,150

BUILDING C: 2020 ADDITION (NO WORK THIS AREA)

GROUP R-1

TYPE V-B CONSTRUCTION

NFPA 13R AUTO SPRINKLER THROUGHOUT

2 STORIES

3,150 SF/FLOOR

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:12:53 PM

G2-20

FIRST AND

SECOND FLOOR

CODE PLANS AND

CODE DATA

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

G2-20 FIRST AND SECOND FLOOR CODE PLANS AND CODE DATA

200 34920 G2-20

SHEET NOT VALID UNLESS THIS TEXT IS COLOR.

1/16" = 1'-0"1

CODE DATA PLAN - FIRST FLOOR

1/16" = 1'-0"2

CODE DATA PLAN - SECOND FLOOR

KEYPLAN

A

B

NOT TO SCALE

CODE KEY PLAN

D

D D

W W

W W

W

D

D

D

D D

D W

W W

W W

W

UP

UP

DINING

KITCHEN

164E

STORAGE

KITCHEN

164D

STORAGE

KITCHEN

ENTRY

OFFICE

LATRINE

ENTRY

ELECTRICAL

SCULLERY

MECHANICAL

JANITORIAL

STORAGE

SUPPLY

OFFICE

OFFICE

LAUNDRY

LATRINE A

LATRINE B

JANITORIAL

CORRIDOR

CORRIDOR

BARRACKS

A

BARRACKS

B

ENTRY

DAY ROOM

ENTRY

LAUNDRY

LATRINE D 103

LATRINE C

JANITORIAL

CORRIDOR

BARRACKS

C

BARRACKS

D

114B

STAIRS

114A

STAIRS

LATRINE

MECHANICAL

CORRIDOR

BARRACK

BARRACK

MECHANICAL

VESTIBULE

VESTIBULE

FLOOR PLAN LEGEND

SHADED REGION INDICATES AREA OF PLANS THAT

ARE NOT INCLUDED IN SCOPE OF WORK.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:12:57 PM

A1-11

FIRST FLOOR

DEMOLITION

PLAN - OVERALL

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-11 FIRST FLOOR DEMOLITION PLAN - OVERALL

400 34920 A1-11

3/32" = 1'-0"1

FIRST FLOOR DEMOLITION PLAN - OVERALL

KEYPLAN

A

B

D

D D

W W

W W

W

D

D

D D

D D

W W

W W

W W

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

DEMOLITION

1/ A

1-

B

1/ A1-11B

DINING

KITCHEN

164E

STORAGE

KITCHEN

164D

STORAGE

KITCHEN

ENTRY

OFFICE

LATRINE

ENTRY

ELECTRICAL

SCULLERY

MECHANICAL

JANITORIAL

STORAGE

SUPPLY

OFFICE

OFFICE

LAUNDRY

LATRINE A

LATRINE B

JANITORIAL

CORRIDOR

CORRIDOR

BARRACKS

A

BARRACKS

B

ENTRY

DAY ROOM

ENTRY

LAUNDRY

LATRINE D

LATRINE C

JANITORIAL

CORRIDOR

BARRACKS

C

BARRACKS

D

114A

STAIRS

114B

STAIRS

D6

D6

D6

D2

D3

D2

D6

D3

D6

D4

D4

D1D1

D8

D8

D8

D8

D1D1

D2

D3

D4

D6

D6

D2

D4

D6

D3

D6

D9

D9

D9

D9

D9

D9

D11

D15 D15

D15 D15

D5

D5

D1 D1

D1 D1

DEMOLITION SHEET NOTES

A. EXISTING CONDITIONS SHOWN ON DRAWINGS REPRESENT

CURRENT BUILDING. IT IS THE RESPONSIBILITY OF THE

CONTRACTOR TO EXAMINE THE DRAWINGS AND FIELD

VERIFY EXISTING CONDITIONS TO DETERMINE SCOPE OF

DEMOLITION WORK REQUIRED TO COMPLETE THE

REMODELING WORK INDICATED ON THE DRAWINGS PRIOR

TO PERFORMING WORK. ADDITIONAL WORK THAT IS

REQUIRED, WAS VISIBLE, AND COULD HAVE BEEN IDENTIFIED

DURING BIDDING SHALL BE COMPLETED BY THE

RESPONSIBLE TRADE CONTRACTOR(S) AT NO ADDITIONAL

COST TO THE OWNER.

B. REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR

REVIEW. WORK DONE WITHOUT RESOLUTION OF

DISCREPANCIES MUST BE REDONE AT THE REQUEST OF THE

ARCHITECT AT NO ADDITIONAL COST TO THE CONTRACT.

C. DEMOLITION OF ANY EXISTING CONSTRUCTION SHALL

INCLUDE WHAT IS NECESSARY AND REQUIRED TO

ACCOMMODATE THE REQUIREMENTS OF NEW

CONSTRUCTION.

D. CONTRACTOR TO BE RESPONSIBLE FOR PROTECTING ANY

LOOSE FURNISHINGS (CHAIRS, TABLES, DESKS, ETC.) AND

MOVING AS NEEDED. CONTRACTOR TO BE RESPONSIBLE

FOR DISCONNECTING ALL UTILITY CONNECTIONS TO

WASHING MACHINES AND DRYERS TO MOVE THE MACHINES

AS NECESSARY FOR PAINTING WORK.

E. VERIFY WITH OWNER FOR ITEMS TO BE SALVAGED BEFORE

STARTING DEMOLITION WORK.

F. CONSTRUCT DUST PROOF PARTITIONS TO SEPARATE AREAS

OF CONSTRUCTION FROM ADJACENT OCCUPIED AREAS

OUTSIDE SCOPE OF CONSTRUCTION.

G. REQUIRED MEANS OF EGRESS FROM THE BUILDING SHALL

BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION

WHEN THE BUILDING REMAINS OCCUPIED. IN THE EVENT

THAT AN EXISTING MEANS OF EGRESS CANNOT BE

MAINTAINED, THE GENERAL CONTRACTOR SHALL PROVIDE

AN APPROVED TEMPORARY MEANS OF EGRESS.

H. MAINTAIN THE INTEGRITY OF ALL EXISTING RATED

ELEMENTS, FIRE SEAL ANY PENETRATIONS WITH U.L.

APPROVED ASSEMBLY.

I. CONTRACTOR IS TO VERIFY THE EXACT LOCATION OF ALL

EXISTING UTILITIES PRIOR TO DEMOLITION ACTIVITIES.

J. DO NOT INTERRUPT EXISTING UTILITIES, EXCEPT WHEN

AUTHORIZED IN WRITING BY AHJ. PROVIDE TEMPORARY

SERVICES DURING INTERRUPTIONS TO EXISTING UTILITIES,

AS ACCEPTABLE TO GOVERNING AUTHORITIES.

K. WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED,

RELOCATED, OR ABANDONED, PROVIDE BYPASS

CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE

BEFORE PROCEEDING WITH REMOVAL.

L. PREP SURFACES FOR NEW FINISHES IN EVERY ROOM.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:00 PM

A1-11A

FIRST FLOOR

DEMOLITION

PLAN - AREA A

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-11A FIRST FLOOR DEMOLITION PLAN - AREA A

400 34920 A1-11A

1/8" = 1'-0"1

FIRST FLOOR DEMOLITION PLAN - AREA A

KEYPLAN

A

KEYNOTE LEGEND

D1 DEMOLISH ALL EXISTING BATHROOM PARTITIONS,

ACCESSORIES, AND MOUNTING HARDWARE.

D2 DEMOLISH ALL EXISTING PAPER TOWEL DISPENSERS AND

MOUNTING HARDWARE.

D3 DEMOLISH ALL EXISTING SINKS AND FAUCETS.

D4 DEMOLISH ALL EXISTING COUNTERTOPS, BACKSPLASH, AND

SUPPORT BRACKETS. REPAIR WALL AS REQUIRED FROM

DEMO OF TALL BACKSPLASH. PREP SURFACE FOR NEW

FINISHES.

D5 DEMOLISH EXISTING DOOR FRAME, DOOR PANEL, SIDELITES

AND ACCESSORIES. SAVE EXISTING HARDWARE TO REUSE

FOR NEW DOOR. PATCH AND REPAIR ADJACENT SURFACES AS

NECESSARY.

D6 DEMOLISH ALL EXISTING SOAP DISPENSERS AND MOUNTING

HARDWARE.

D8 DEMOLISH EXISTING WALL MOUNTED SHOWER BENCH.

PATCH/REPAIR WALL AS REQUIRED. PREP FOR NEW FINISHES.

D9 REMOVE ALL ROOM, WAYFINDING, AND DOOR NUMBER

SIGNAGE THROUGHOUT BUILDING. PATCH/REPAIR SURFACES

AS REQUIRED FOR NEW FINISHES.

D11 ALL EXISTING RESTROOM ACCESSORIES AND FIXTURES TO

REMAIN. REMOVE AND REINSTALL AS REQUIRED FOR

PAINTING WORK.

D15 EXISTING MIRRORS TO REMAIN. PROTECT DURING

CONSTRUCTION.

UP

DN

DN

DN

1/ A

1-

A

1/ A1-11A

ENTRY

LATRINE D

LATRINE C

JANITORIAL

CORRIDOR

BARRACKS

D

BARRACKS

D

BARRACKS

C

D8

MECHANICAL

LATRINE

MECHANICAL

VESTIBULE

CORRIDOR

VESTIBULE

BARRACK

BARRACK

D2

D3

D4

D6

D6

D2

D4

D6

D3

D6

D9

D7

D7

D15 D15

1/ A

1-

A

1/ A1-12A

BARRACKS

H

LATRINE H

LATRINE G

CORRIDOR

JANITORIAL

CORRIDOR

CORRIDOR

BARRACKS

G

MECHANICAL

LATRINE

MECHANICAL

VESTIBULE

VESTIBULE

CORRIDOR

BARRACK

BARRACK

D8D2 D2 D6

D4

D3

D6

D6

D4

D3

D6

D9

D9

D7

D7

D15

D15

D16 D16

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

DEMOLITION

DEMOLITION SHEET NOTES

A. EXISTING CONDITIONS SHOWN ON DRAWINGS REPRESENT

CURRENT BUILDING. IT IS THE RESPONSIBILITY OF THE

CONTRACTOR TO EXAMINE THE DRAWINGS AND FIELD

VERIFY EXISTING CONDITIONS TO DETERMINE SCOPE OF

DEMOLITION WORK REQUIRED TO COMPLETE THE

REMODELING WORK INDICATED ON THE DRAWINGS PRIOR

TO PERFORMING WORK. ADDITIONAL WORK THAT IS

REQUIRED, WAS VISIBLE, AND COULD HAVE BEEN IDENTIFIED

DURING BIDDING SHALL BE COMPLETED BY THE

RESPONSIBLE TRADE CONTRACTOR(S) AT NO ADDITIONAL

COST TO THE OWNER.

B. REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR

REVIEW. WORK DONE WITHOUT RESOLUTION OF

DISCREPANCIES MUST BE REDONE AT THE REQUEST OF THE

ARCHITECT AT NO ADDITIONAL COST TO THE CONTRACT.

C. DEMOLITION OF ANY EXISTING CONSTRUCTION SHALL

INCLUDE WHAT IS NECESSARY AND REQUIRED TO

ACCOMMODATE THE REQUIREMENTS OF NEW

CONSTRUCTION.

D. CONTRACTOR TO BE RESPONSIBLE FOR PROTECTING ANY

LOOSE FURNISHINGS (CHAIRS, TABLES, DESKS, ETC.) AND

MOVING AS NEEDED. CONTRACTOR TO BE RESPONSIBLE

FOR DISCONNECTING ALL UTILITY CONNECTIONS TO

WASHING MACHINES AND DRYERS TO MOVE THE MACHINES

AS NECESSARY FOR PAINTING WORK.

E. VERIFY WITH OWNER FOR ITEMS TO BE SALVAGED BEFORE

STARTING DEMOLITION WORK.

F. CONSTRUCT DUST PROOF PARTITIONS TO SEPARATE AREAS

OF CONSTRUCTION FROM ADJACENT OCCUPIED AREAS

OUTSIDE SCOPE OF CONSTRUCTION.

G. REQUIRED MEANS OF EGRESS FROM THE BUILDING SHALL

BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION

WHEN THE BUILDING REMAINS OCCUPIED. IN THE EVENT

THAT AN EXISTING MEANS OF EGRESS CANNOT BE

MAINTAINED, THE GENERAL CONTRACTOR SHALL PROVIDE

AN APPROVED TEMPORARY MEANS OF EGRESS.

H. MAINTAIN THE INTEGRITY OF ALL EXISTING RATED

ELEMENTS, FIRE SEAL ANY PENETRATIONS WITH U.L.

APPROVED ASSEMBLY.

I. CONTRACTOR IS TO VERIFY THE EXACT LOCATION OF ALL

EXISTING UTILITIES PRIOR TO DEMOLITION ACTIVITIES.

J. DO NOT INTERRUPT EXISTING UTILITIES, EXCEPT WHEN

AUTHORIZED IN WRITING BY AHJ. PROVIDE TEMPORARY

SERVICES DURING INTERRUPTIONS TO EXISTING UTILITIES,

AS ACCEPTABLE TO GOVERNING AUTHORITIES.

K. WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED,

RELOCATED, OR ABANDONED, PROVIDE BYPASS

CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE

BEFORE PROCEEDING WITH REMOVAL.

L. PREP SURFACES FOR NEW FINISHES IN EVERY ROOM.

FLOOR PLAN LEGEND

SHADED REGION INDICATES AREA OF PLANS THAT

ARE NOT INCLUDED IN SCOPE OF WORK.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:10 PM

A1-11B

FIRST AND

SECOND FLOOR

DEMOLITION

PLAN - AREA B

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-11B FIRST AND SECOND FLOOR DEMOLITION PLAN - AREA B

400 34920 A1-11B

1/8" = 1'-0"1

FIRST FLOOR DEMOLITION PLAN - AREA B

KEYPLAN

B

1/8" = 1'-0"2

SECOND FLOOR DEMOLITION PLAN - AREA B

KEYNOTE LEGEND

D2 DEMOLISH ALL EXISTING PAPER TOWEL DISPENSERS AND

MOUNTING HARDWARE.

D3 DEMOLISH ALL EXISTING SINKS AND FAUCETS.

D4 DEMOLISH ALL EXISTING COUNTERTOPS, BACKSPLASH, AND

SUPPORT BRACKETS. REPAIR WALL AS REQUIRED FROM

DEMO OF TALL BACKSPLASH. PREP SURFACE FOR NEW

FINISHES.

D6 DEMOLISH ALL EXISTING SOAP DISPENSERS AND MOUNTING

HARDWARE.

D7 REMOVE DOOR ALARM SIGNAGE FOR PAINTING. SALVAGE FOR

REINSTALLATION.

D8 DEMOLISH EXISTING WALL MOUNTED SHOWER BENCH.

PATCH/REPAIR WALL AS REQUIRED. PREP FOR NEW FINISHES.

D9 REMOVE ALL ROOM, WAYFINDING, AND DOOR NUMBER

SIGNAGE THROUGHOUT BUILDING. PATCH/REPAIR SURFACES

AS REQUIRED FOR NEW FINISHES.

D15 EXISTING MIRRORS TO REMAIN. PROTECT DURING

CONSTRUCTION.

D16 DEMOLISH SIGNAGE FOR FLUSHING INFORMATION AT TOILET

PARTITION AND URINAL.

WWWWWW

W W

W W

D D

D D

D D D D D D D

DN

DN

DN

LAUNDRY

MECHANICAL

CORRIDOR

CORRIDOR

LATRINE E

LATRINE F

CORRIDOR

CORRIDOR

CORRIDOR

BARRACKS

E

BARRACKS

F

LATRINE H 201

LATRINE G

CORRIDOR

CORRIDOR

CORRIDOR

BARRACKS

H

BARRACKS

G

JANITORIAL

JANITORIAL

114A

STAIRS

114B

STAIRS

FLOOR PLAN LEGEND

SHADED REGION INDICATES AREA OF PLANS THAT

ARE NOT INCLUDED IN SCOPE OF WORK.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:15 PM

A1-12

SECOND FLOOR

DEMOLITION

PLAN - OVERALL

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-12 SECOND FLOOR DEMOLITION PLAN - OVERALL

400 34920 A1-12

3/32" = 1'-0"1

SECOND FLOOR DEMOLITION PLAN - OVERALL

KEYPLAN

A

B

W

W W

D D

D D

D D D D D D D

2/ A

1-

B

2/ A1-11B

LATRINE H

LATRINE G

CORRIDOR

CORRIDOR

JANITORIAL

CORRIDOR

CORRIDOR

CORRIDOR

BARRACKS

G

BARRACKS

H

MECHANICAL

LAUNDRY

BARRACKS

E

BARRACKS

F

LATRINE F

LATRINE E

CORRIDOR

JANITORIAL

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

114A

STAIRS

114B

STAIRS

D8

D8

D8

D8

D6

D4

D6

D3

D1D1

D6

D3

D4

D6

D1 D1

D2 D2 D6

D4

D3

D6

D6

D4

D3

D6

D9

D9

D9

D9

D9

D9

D9

D15

D15

D15

D15

D1D1

D1D1

D2D2

D16

D16

D16

D16 D16

D16

D16

D16

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

DEMOLITION

DEMOLITION SHEET NOTES

A. EXISTING CONDITIONS SHOWN ON DRAWINGS REPRESENT

CURRENT BUILDING. IT IS THE RESPONSIBILITY OF THE

CONTRACTOR TO EXAMINE THE DRAWINGS AND FIELD

VERIFY EXISTING CONDITIONS TO DETERMINE SCOPE OF

DEMOLITION WORK REQUIRED TO COMPLETE THE

REMODELING WORK INDICATED ON THE DRAWINGS PRIOR

TO PERFORMING WORK. ADDITIONAL WORK THAT IS

REQUIRED, WAS VISIBLE, AND COULD HAVE BEEN IDENTIFIED

DURING BIDDING SHALL BE COMPLETED BY THE

RESPONSIBLE TRADE CONTRACTOR(S) AT NO ADDITIONAL

COST TO THE OWNER.

B. REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR

REVIEW. WORK DONE WITHOUT RESOLUTION OF

DISCREPANCIES MUST BE REDONE AT THE REQUEST OF THE

ARCHITECT AT NO ADDITIONAL COST TO THE CONTRACT.

C. DEMOLITION OF ANY EXISTING CONSTRUCTION SHALL

INCLUDE WHAT IS NECESSARY AND REQUIRED TO

ACCOMMODATE THE REQUIREMENTS OF NEW

CONSTRUCTION.

D. CONTRACTOR TO BE RESPONSIBLE FOR PROTECTING ANY

LOOSE FURNISHINGS (CHAIRS, TABLES, DESKS, ETC.) AND

MOVING AS NEEDED. CONTRACTOR TO BE RESPONSIBLE

FOR DISCONNECTING ALL UTILITY CONNECTIONS TO

WASHING MACHINES AND DRYERS TO MOVE THE MACHINES

AS NECESSARY FOR PAINTING WORK.

E. VERIFY WITH OWNER FOR ITEMS TO BE SALVAGED BEFORE

STARTING DEMOLITION WORK.

F. CONSTRUCT DUST PROOF PARTITIONS TO SEPARATE AREAS

OF CONSTRUCTION FROM ADJACENT OCCUPIED AREAS

OUTSIDE SCOPE OF CONSTRUCTION.

G. REQUIRED MEANS OF EGRESS FROM THE BUILDING SHALL

BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION

WHEN THE BUILDING REMAINS OCCUPIED. IN THE EVENT

THAT AN EXISTING MEANS OF EGRESS CANNOT BE

MAINTAINED, THE GENERAL CONTRACTOR SHALL PROVIDE

AN APPROVED TEMPORARY MEANS OF EGRESS.

H. MAINTAIN THE INTEGRITY OF ALL EXISTING RATED

ELEMENTS, FIRE SEAL ANY PENETRATIONS WITH U.L.

APPROVED ASSEMBLY.

I. CONTRACTOR IS TO VERIFY THE EXACT LOCATION OF ALL

EXISTING UTILITIES PRIOR TO DEMOLITION ACTIVITIES.

J. DO NOT INTERRUPT EXISTING UTILITIES, EXCEPT WHEN

AUTHORIZED IN WRITING BY AHJ. PROVIDE TEMPORARY

SERVICES DURING INTERRUPTIONS TO EXISTING UTILITIES,

AS ACCEPTABLE TO GOVERNING AUTHORITIES.

K. WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED,

RELOCATED, OR ABANDONED, PROVIDE BYPASS

CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE

BEFORE PROCEEDING WITH REMOVAL.

L. PREP SURFACES FOR NEW FINISHES IN EVERY ROOM.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:17 PM

A1-12A

SECOND FLOOR

DEMOLITION

PLAN - AREA A

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-12A SECOND FLOOR DEMOLITION PLAN - AREA A

400 34920 A1-12A

1/8" = 1'-0"1

SECOND FLOOR DEMOLITION PLAN - AREA A

KEYPLAN

A

KEYNOTE LEGEND

D1 DEMOLISH ALL EXISTING BATHROOM PARTITIONS,

ACCESSORIES, AND MOUNTING HARDWARE.

D2 DEMOLISH ALL EXISTING PAPER TOWEL DISPENSERS AND

MOUNTING HARDWARE.

D3 DEMOLISH ALL EXISTING SINKS AND FAUCETS.

D4 DEMOLISH ALL EXISTING COUNTERTOPS, BACKSPLASH, AND

SUPPORT BRACKETS. REPAIR WALL AS REQUIRED FROM

DEMO OF TALL BACKSPLASH. PREP SURFACE FOR NEW

FINISHES.

D6 DEMOLISH ALL EXISTING SOAP DISPENSERS AND MOUNTING

HARDWARE.

D8 DEMOLISH EXISTING WALL MOUNTED SHOWER BENCH.

PATCH/REPAIR WALL AS REQUIRED. PREP FOR NEW FINISHES.

D9 REMOVE ALL ROOM, WAYFINDING, AND DOOR NUMBER

SIGNAGE THROUGHOUT BUILDING. PATCH/REPAIR SURFACES

AS REQUIRED FOR NEW FINISHES.

D15 EXISTING MIRRORS TO REMAIN. PROTECT DURING

CONSTRUCTION.

D16 DEMOLISH SIGNAGE FOR FLUSHING INFORMATION AT TOILET

PARTITION AND URINAL.

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

F

WS

F

W S

A A

DINING

KITCHEN

164E

STORAGE

KITCHEN

164D

STORAGE

KITCHEN

ENTRY

OFFICE

LATRINE

ENTRY

ELECTRICAL

SCULLERY

MECHANICAL

JANITORIAL

STORAGE

SUPPLY

OFFICE

OFFICE

LAUNDRY

LATRINE A

LATRINE B

JANITORIAL

CORRIDOR

CORRIDOR

BARRACKS

A

BARRACKS

B

ENTRY

DAY ROOM

ENTRY

LAUNDRY

LATRINE D 103

LATRINE C

JANITORIAL

CORRIDOR

BARRACKS

C

BARRACKS

D

114B

STAIRS

114A

STAIRS

LATRINE

MECHANICAL

CORRIDOR

BARRACK

BARRACK

MECHANICAL

VESTIBULE

VESTIBULE

FLOOR PLAN LEGEND

SHADED REGION INDICATES AREA OF PLANS THAT

ARE NOT INCLUDED IN SCOPE OF WORK.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:22 PM

A1-13

FIRST FLOOR

REFLECTED

CEILING

DEMOLITION

PLAN - OVERALL

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-13 FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL

400 34920 A1-13

3/32" = 1'-0"1

FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL

KEYPLAN

A

B

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

F

WS

F

W S

A A

164E

STORAGE

KITCHEN

164D

STORAGE

KITCHEN

KITCHEN

ENTRY

LATRINE

OFFICE

ENTRY

STORAGE

SUPPLY

DINING

SCULLERY

ELECTRICAL

JANITORIAL

MECHANICAL

OFFICE

OFFICE

LAUNDRY

LATRINE A

LATRINE B

CORRIDOR

BARRACKS

A

BARRACKS

B

DAY ROOM

CORRIDOR

LAUNDRY

LATRINE D

LATRINE C

CORRIDOR

ENTRY

JANITORIAL

JANITORIAL

ENTRY

D10

D10

D10

D10

D10

D12

BARRACKS

C

BARRACKS

D

D14 D14

D14

D14

D14

D14

D14

D14

D14

D14

D14

D14

D14

D14

D14

D13 D13

D13 D13 D13 D13 D13 D13

D13

D13

D13

D13 D13 D13

D13

D13

D13D13D13

D14D14

D14

D14

D14

D14

D14

D14

1/ A1-13B

1/ A

1-

B

D14

D14 D14

D14 D14

D14

D18

D18

CEILING DEMOLITION SHEET NOTES

A. REPAIR CRACKING, HOLES, DEFECTS, ETC. AT ALL EXISTING GYPSUM

BOARD CEILINGS IN ROOMS THAT WORK IS OCCURRING.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:24 PM

A1-13A

FIRST FLOOR

REFLECTED

CEILING

DEMOLITION

PLAN - AREA A

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-13A FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A

400 34920 A1-13A

1/8" = 1'-0"1

FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A

KEYPLAN

A

KEYNOTE LEGEND

17 EXISTING CEILING TO REMAIN. DO NOT PAINT CEILING. NO

ADDITIONAL WORK REQUIRED.

D10 DEMO/REMOVE ACOUSTIC CEILING TILE AND GRID IN ITS

ENTIRETY. EXISTING LIGHTING AND MECHANICAL

EQUIPMENT (SUPPLY/RETURN GRILLES) TO BE REUSED.

REMOVE AND SALVAGE FOR REINSTALLATION.

D12 DEMOLISH EXISTING ACOUSTIC CEILING TILE BULKHEAD &

SOFFIT. DEMOLISH EXISTING CEILING GRID AND/OR

FRAMING AROUND MECHANICAL/PLUMBING EQUIPMENT,

PAINT EQUIPMENT TO MATCH ADJACENT WALL COLOR.

REFER TO FINISH PLANS.

D13 REMOVE EXISTING WINDOW TREATMENTS. SALVAGE FOR

REUSE.

D14 REPAIR ALL EXISTING CRACKING IN GYPSUM BOARD

CEILING. PREPARE FOR NEW PAINT. REFER TO FINISH PLANS

AND REFLECTED CEILING PLANS.

D18 REPAIR ANY CRACKING IN EXISTING PRECAST PANEL

CEILING. PREPARE FOR NEW PAINT. REFER TO FINISH PLANS

AND REFLECTED CEILING PLANS.

S

S

S

S

S

S

S

S

S

S

BARRACKS

D

BARRACKS

C

CORRIDOR

LATRINE D

LATRINE D

LATRINE C

LATRINE C

CORRIDOR

ENTRY

JANITORIAL

BARRACK

BARRACK

CORRIDOR

VESTIBULE

VESTIBULE

MECHANICAL

LATRINE

1/ A

1-

A

1/ A1-13A

D18

D18

BARRACKS

H

BARRACKS

G

LATRINE H

LATRINE H

LATRINE G

LATRINE G

CORRIDOR

CORRIDOR

CORRIDOR

LATRINE

MECHANICAL

CORRIDOR

VESTIBULE

VESTIBULE

BARRACK

BARRACK

JANITORIAL

1/ A1-14A

1/ A

1-

A

D14

D14

FLOOR PLAN LEGEND

SHADED REGION INDICATES AREA OF PLANS THAT

ARE NOT INCLUDED IN SCOPE OF WORK.

CEILING DEMOLITION SHEET NOTES

A. REPAIR CRACKING, HOLES, DEFECTS, ETC. AT ALL EXISTING GYPSUM

BOARD CEILINGS IN ROOMS THAT WORK IS OCCURRING.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:33 PM

A1-13B

FIRST AND

SECOND FLOOR

REFLECTED

CEILING

DEMOLITION

PLANS - AREA B

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-13B FIRST AND SECOND FLOOR REFLECTED CEILING DEMOLITION PLANS - AREA B

400 34920 A1-13B

1/8" = 1'-0"1

FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA B

1/8" = 1'-0"2

SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA B

KEYPLAN

B

KEYNOTE LEGEND

D14 REPAIR ALL EXISTING CRACKING IN GYPSUM BOARD

CEILING. PREPARE FOR NEW PAINT. REFER TO FINISH

PLANS AND REFLECTED CEILING PLANS.

D18 REPAIR ANY CRACKING IN EXISTING PRECAST PANEL

CEILING. PREPARE FOR NEW PAINT. REFER TO FINISH

PLANS AND REFLECTED CEILING PLANS.

S

S

S

S

S

S

S

S

S

S

S

S

S

S F

WS

FLOOR PLAN LEGEND

SHADED REGION INDICATES AREA OF PLANS THAT

ARE NOT INCLUDED IN SCOPE OF WORK.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:37 PM

A1-14

SECOND FLOOR

REFLECTED

CEILING

DEMOLITION

PLAN - OVERALL

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-14 SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL

400 34920 A1-14

3/32" = 1'-0"1

SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL

KEYPLAN

A

B

S

S

S

S

S

S

S

S

S

S

S

S

F

WS

MECHANICAL

LAUNDRY

BARRACKS

H

BARRACKS

G

LATRINE H

BARRACKS

E

BARRACKS

F

LATRINE G

LATRINE F

LATRINE E

CORRIDOR

CORRIDOR

CORRIDOR

JANITORIAL

JANITORIAL

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

114A

STAIRS

114B

STAIRS

D14

D14 D14

D14 D14

D14D14

D14

D14 D14

D14

D14

D14

D14

2/ A1-13B

2/ A

1-

B

D14

D14

D14

D14

D14

D14 D14

D14

D14

D14

D14

D14

D14 D14

D14

D14

D14

D14

CEILING DEMOLITION SHEET NOTES

A. REPAIR CRACKING, HOLES, DEFECTS, ETC. AT ALL EXISTING GYPSUM

BOARD CEILINGS IN ROOMS THAT WORK IS OCCURRING.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:40 PM

A1-14A

SECOND FLOOR

REFLECTED

CEILING

DEMOLITION

PLAN - AREA A

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-14A SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A

400 34920 A1-14A

1/8" = 1'-0"1

SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A

KEYPLAN

A

KEYNOTE LEGEND

17 EXISTING CEILING TO REMAIN. DO NOT PAINT CEILING. NO

ADDITIONAL WORK REQUIRED.

D14 REPAIR ALL EXISTING CRACKING IN GYPSUM BOARD

CEILING. PREPARE FOR NEW PAINT. REFER TO FINISH

PLANS AND REFLECTED CEILING PLANS.

D

D D

W W

W W

W

D

D

D

D D

D W

W W

W W

W

UP

UP

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

NEW CONSTRUCTION

FLOOR PLAN SHEET NOTES

• ALL WALL MOUNTED ITEMS TO SIT FLUSH ON A WALL

SURFACE. IN INSTANCES WHERE A WALL MOUNTED ITEM IS

TO BE INSTALLED ON TWO DIFFERENT FINISH

THICKNESSES, PROVIDE A HARDBOARD BACKER FOR THE

ITEM TO SIT FLUSH. PROVIDE SEALANT AROUND ALL EDGES

OF BACKER AND PAINT TO MATCH ADJACENT SURFACE

164E

STORAGE

KITCHEN

164D

STORAGE

KITCHEN

KITCHEN

ENTRY

LATRINE

OFFICE

ENTRY

DINING

ELECTRICAL

SCULLERY

JANITORIAL

MECHANICAL

STORAGE

SUPPLY

OFFICE

OFFICE

LAUNDRY

LATRINE A

LATRINE B

CORRIDOR

CORRIDOR

BARRACKS

A

BARRACKS

B

DAY ROOM

LAUNDRY

LATRINE D 103

LATRINE C

CORRIDOR

BARRACKS

D

BARRACKS

C

114B

STAIRS

114A

STAIRS

HM2

BARRACK

BARRACK

CORRIDOR

LATRINE

MECHANICAL

VESTIBULE

VESTIBULE

MECHANICAL

FLOOR PLAN LEGEND

SHADED REGION INDICATES AREA OF PLANS THAT

ARE NOT INCLUDED IN SCOPE OF WORK.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:45 PM

A1-21

FIRST FLOOR

PLAN - OVERALL

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-21 FIRST FLOOR PLAN - OVERALL

400 34920 A1-21

3/32" = 1'-0"1

FIRST FLOOR PLAN - OVERALL

KEYPLAN

A

B

D

D D

W W

W W

W

D

D

D

D D

D W

W W

W W

W

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

NEW CONSTRUCTION

FLOOR PLAN SHEET NOTES

• ALL WALL MOUNTED ITEMS TO SIT FLUSH ON A WALL

SURFACE. IN INSTANCES WHERE A WALL MOUNTED ITEM IS

TO BE INSTALLED ON TWO DIFFERENT FINISH

THICKNESSES, PROVIDE A HARDBOARD BACKER FOR THE

ITEM TO SIT FLUSH. PROVIDE SEALANT AROUND ALL EDGES

OF BACKER AND PAINT TO MATCH ADJACENT SURFACE

1/ A

1-

B

1/ A1-21B

A5-11

LATRINE D

LATRINE C

164E

STORAGE

KITCHEN

164D

STORAGE

KITCHEN

ENTRY

KITCHEN

LATRINE

OFFICE

ENTRY

DINING

STORAGE

SUPPLY

OFFICE

OFFICE

SCULLERY

ELECTRICAL

MECHANICAL

BARRACKS

A

BARRACKS

B

CORRIDOR

LATRINE A

LATRINE B

LAUNDRY

ENTRY

DAY ROOM

CORRIDOR

LAUNDRY

ENTRY

CORRIDOR

JANITORIAL

JANITORIAL

JANITORIAL

114B

STAIRS

114A

STAIRS

HM1

HM2

A

BARRACKS

D

BARRACKS

C

B

DOOR TYPES

FG1

FULL GLASS W/

CENTER RAIL

8" 8"

FRG-1

FRG-1

METAL FRAME

FRAME TYPES

2"

WIDTH

DOOR 2"

D

O O

R H

E

IG

H T

REUSE EXISTING DOOR

HARDWARE FOR NEW DOOR

FRG-1

2"1' - 8"2"

WIDTH

DOOR2"

5' - 2"

D O

O R

H E

IG

H

T

REUSE EXISTING DOOR

HARDWARE FOR NEW DOOR

FRG-1

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:48 PM

A1-21A

FIRST FLOOR

PLAN - AREA A &

DOOR SCHEDULE,

DOOR AND FRAME

TYPES

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-21A FIRST FLOOR PLAN - AREA A & DOOR SCHEDULE, DOOR AND FRAME TYPES

400 34920 A1-21A

1/8" = 1'-0"1

FIRST FLOOR PLAN - AREA A

KEYPLAN

A

GLAZING SCHEDULE

MARK MATERIAL THICKNESS COMMENTS

OTHER

FRG-1 FIRE RESISTANCE

RATED GLAZING UNIT

DOOR SCHEDULE

MARK ROOM NAME WIDTH HEIGHT

PANEL

THICKNESS

DOOR

TYPE DOOR MATERIAL

FRAME

TYPE FRAME MATERIAL

FIRE

RATING

HARDWARE

GROUP COMMENTS

156A ENTRY 3' - 0" 7' - 10" 0' - 1 3/4" FG1 HOLLOW METAL 1 HOLLOW METAL 60 MIN REUSE DOOR HARDWARE

156B ENTRY 3' - 0" 7' - 10" 0' - 1 3/4" FG1 HOLLOW METAL 1 HOLLOW METAL 60 MIN REUSE DOOR HARDWARE

HM1 HM2

DN

DN

DN

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

NEW CONSTRUCTION

FLOOR PLAN SHEET NOTES

• ALL WALL MOUNTED ITEMS TO SIT FLUSH ON A WALL

SURFACE. IN INSTANCES WHERE A WALL MOUNTED ITEM IS

TO BE INSTALLED ON TWO DIFFERENT FINISH

THICKNESSES, PROVIDE A HARDBOARD BACKER FOR THE

ITEM TO SIT FLUSH. PROVIDE SEALANT AROUND ALL EDGES

OF BACKER AND PAINT TO MATCH ADJACENT SURFACE

1/ A1-21A

1/ A

1-

A

LATRINE D

LATRINE C

BARRACKS

D

BARRACKS

C

ENTRY

CORRIDOR

JANITORIAL

MECHANICAL

LATRINE

MECHANICAL

VESTIBULE

CORRIDOR

VESTIBULE

BARRACK

BARRACK

1/ A

1-

A

1/ A1-22A

BARRACKS

H

BARRACKS

G

CORRIDOR

LATRINE H

LATRINE G

CORRIDOR

CORRIDOR

JANITORIAL

MECHANICAL

VESTIBULE

CORRIDOR

LATRINE

VESTIBULE

MECHANICAL

BARRACK

BARRACK

FLOOR PLAN LEGEND

SHADED REGION INDICATES AREA OF PLANS THAT

ARE NOT INCLUDED IN SCOPE OF WORK.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:13:58 PM

A1-21B

FIRST AND

SECOND FLOOR

PLAN - AREA B

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-21B FIRST AND SECOND FLOOR PLAN - AREA B

400 34920 A1-21B

1/8" = 1'-0"1

FIRST FLOOR PLAN - AREA B

1/8" = 1'-0"2

SECOND FLOOR PLAN - AREA B

KEYPLAN

B

W

W W

D D

D D

D D D D D D D

DN

DN

DN

LAUNDRY

MECHANICAL

CORRIDOR

CORRIDOR

LATRINE E

LATRINE F

CORRIDOR

CORRIDOR

CORRIDOR

BARRACKS

E

BARRACKS

F

LATRINE H 201

LATRINE G

CORRIDOR

CORRIDOR

CORRIDOR

BARRACKS

H

BARRACKS

G

JANITORIAL

JANITORIAL

114A

STAIRS

114B

STAIRS

FLOOR PLAN LEGEND

SHADED REGION INDICATES AREA OF PLANS THAT

ARE NOT INCLUDED IN SCOPE OF WORK.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

9/8/2026 3:14:02 PM

A1-22

SECOND FLOOR

PLAN - OVERALL

IOWA ARMY

NATIONAL GUARD

CAMP DODGE, JOHNSTON IOWA

34920 Arch R26

MJT

GMP

09/08/26

GMP

19083733

26-34920

S54 FINISH

UPGRADES

A1-22 SECOND FLOOR PLAN - OVERALL

400 34920 A1-22

3/32" = 1'-0"1

SECOND FLOOR PLAN - OVERALL

KEYPLAN

A

B

W

W W

D D

D D

D D D D D D D

2/ A

1-

B

2/ A1-21B

A5-11

CORRIDOR

LATRINE H

LATRINE G

BARRACKS

E

BARRACKS

F

LAUNDRY

MECHANICAL

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

LATRINE E

LATRINE F

JANITORIAL

JANITORIAL

BARRACKS

H

BARRACKS

G

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

NEW CONSTRUCTION

FLOOR PLAN SHEET NOTES

• ALL WALL MOUNTED ITEMS TO SIT FLUSH ON A WALL

SURFACE. IN INSTANCES WHERE A WALL…

This is the start of the file's text. The full file is on GovTribe.