Drawings.pdf
PDF 14 MB Posted
- Attached to
- S54 FINISH UPGRADES
- Solicitation number
- 34254102
- Issued by
- Polk County, Iowa
About this file
Summary
This is a set of architectural drawings and specifications for the S54 Finish Upgrades project at Camp Dodge, Johnston, Iowa, prepared by I & S Group, Inc. (ISG) for the Iowa Army National Guard. The project encompasses interior repainting work, latrine fixture and accessory upgrades, replacement of select exterior doors, installation of new room identification and wayfinding signage, and related incidental work throughout a two-story residential barracks building (Building A) originally constructed in 1993. The scope of work is classified as a Level 1 Alteration under the 2024 International Existing Building Code, limited to replacement of interior finishes, plumbing fixtures, toilet partitions, accessories, countertops, ceilings, and signage with no changes to occupancy classification or building area. The project involves demolition and finish work across approximately 22,630 square feet on the first floor and 17,150 square feet on the second floor, with extensive documentation including floor plans, reflected ceiling plans, finish schedules, door schedules, and detailed specifications for materials and installation methods.
The drawings were issued on September 8, 2026, with project management overseen by Zach Thompson at ISG's Des Moines office. Work is classified as non-sprinklered Type V-B construction for Building A, with accessibility requirements complying with ADA standards and Department of Defense policy. The contract documents incorporate the 2024 International Building Code, 2024 International Fire Code, 2012 International Energy Conservation Code, 2012 NFPA 101 Life Safety Code, and applicable Iowa Administrative Rules. Specific finish requirements include multiple paint specifications (PNT-1, PNT-1E, PNT-3), installation of grab bars and accessibility features per ADA guidelines on the first floor latrines, retention of existing mirrors and window treatments, and coordination with mechanical, plumbing, electrical, and fire protection systems. The project requires contractor responsibility for surface preparation, protective measures for occupied spaces, coordination of furniture and equipment movement with the building owner, and maintenance of all existing means of egress throughout construction.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Specs.pdf | ||
| Advertisement for Bid.pdf | ||
| Advertisement Rev1.pdf | ||
| TSB_Form (12).pdf | ||
| IFB_Specifications Rev1.pdf | ||
| Performance and Payment Bond (AIA Document A312-2010).html | HTML file | |
| 1443205-event.pdf | ||
| General Conditions (AIA Document A201-2007).html | HTML file | |
| IFB_Drawings.pdf | ||
| Application and Certificate for Payment (AIA Documents G702 and G703-1992).html | HTML file | |
| Form_of_Bid Rev1.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B-53
W420A
S-04A
S-49
W-42
B-61A
B-58A
B-62A
B-62B
S-47
S-73
A-29
S-00
S-103
S-104
S-105
AD-8
S-21A
S-02B
A-09
B-01
A-10A
L-03
W-39Q
W-09
S-57
B-71
S-31
T-06D
W-11
S-30S
W-34
S-28
S-16
B-02
A-17
C-03
A-07
A-28Q
B-25
S-11C
M-07
B-69
B-63
B-67
S-08BS-14
B-03
W-22
B-06
C-01
M-03
AD-06
S-55
S-42
S-04
S-13
S-71
S-40
L-04
W-38Q
W-37Q
S-01
S-021A
M-12
M-01
AD-01
W-05
W-04
S-37
S-34
WP-3
T-33
S-11I
DF-4
S-16I
A-31
B-34
L-11
B-10
S-14C
A-12Q
A-13
A-46
T-06F
B-47
S-53
W-26
S-52
L-10
W-20
S-20
T-06C
S-44
B-03A
S-301
B-39
W-08
B-70
DF-1
S-04H
S-06
AD-02
AD-05
W-12H0
S-43
RT-2
B-18
B-17
S-39
L-07
S-23A
B-33
B-32
B-46
B-55
B-20
DF-2
W-12H1
B-42
B-04
A-21
B-07
B-49
S-29
S-54
A-01
S-50
W-46
A-05
A-04
T-06H
B-37
S-36
W-33
S-32
M-13
W-32
W-36Q
W-03
S-34H
B-57
S-03A
S-12
B-61
A-06A
S-11A
B-30
DF-3
S-101
T-601
B-26
B-35
B-62
B-68
W-12A
W-48
L-05
B-12
PT-01
B-48
T-21
S-60H
S-63
L-09
A-41
B-36
W-40Q L-02
A-06
B-22
DF-5
B-76
B-58
T-06E
B-75
S-05
S-02H
S-16A
B-19
S-23
A-18
A-08
S-21
M-06
B-15
L-06
B-29
W-40
A-25
M-15
B-45
B-51
B-44
S-02
W-41
M-09
B-08
T-06G
PT-06
B-13
A-42
RT-4
T-2702S-17
S-38A
S-302
W-10
W-46H
S-56
C-02
W-46A
S-02A
AD-04
A-22
A-26Q
W-02
W-01
W-00
S-30A
A-62
S-28H
S-38
A-34
M-11
B-27
S-102
B-65
M-08
T-09
W-25
B-43
S-16C
W-06
B-60
B-14
B-11
W-21
B-09
S-59
S-13C
T-06B
S-70
B-40
B-38
W-12
W-47
S-33
S-07
AD-03
A-63
A-23
S-03
B-16
S-12C
L-08
B-28
T-2701
B-59
W-27
W-35
B-05
S-60
A-01A
B-24
B-23
C-04
W-18Q
W-19
S-72
W-32Q
W-14
S-35
S-30H
S-30
S-34A
S-34P
B-50
A-15
S-23T
A-30
AD-07
B-64
B-66
S-08A
B-31
B-21
B-41
A-20Q
A-40
A-02
A-03Q
M-04 M-05
M-10
S-11
S-58
W-07
B-56
S-51
W-15
W-16
T-06A
3259E
2198B 3209C
3203D
3165E
3535A
3583A
3586A
3586B
5541A
2262A
3824A
2187D
3259A
3205A3203
3203B
3267B
3259C
3165C
3203A
4665A
2187F
2187C
4640A
2326A
4410B
3850B
4410A
3729A
2187G
2479A
2289A
3259B
4410C
1350A
2187E
2375A
3165B
3753A
2187H
3850C
2185A2183A
2326B
2467A
3449A
3447A
3802A
3165A
3209A
2187B
3257A
3850A
2447A
2297A
3267A
3800A
2198A
2187A
PROJECT LOCATION
BLDG: S-54
SITE ENTRY
NW 70TH AVE
PROJECT LOCATION
LOCATION MAP
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
PROJECT INDEX:
OWNER: PROJECT ADDRESS: MANAGING OFFICE:
I & S GROUP, INC. (ISG)
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:12:46 PM
G1-10
TITLE SHEET,
SHEET INDEX,
PROJECT
GENERAL NOTES
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
S-54
7105 NW 70TH AVE
CAMP DODGE, JOHNSTON, IOWA
50131
PROJECT MANAGER: ZACH THOMPSON
EMAIL: ZACH.THOMPSON@ISGINC.COM
IOWA ARMY NATIONAL GUARD
7105 NW 70TH AVE
JOHNSTON, IOWA 50131
CAMP DODGE, JOHNSTON, IOWA
G1-10 TITLE SHEET, SHEET INDEX, PROJECT GENERAL NOTES
IOWA ARMY NATIONAL GUARD S54 FINISH UPGRADES
200 34920 G1-10
ISG PROJECT # 26-34920
PROJECT GENERAL NOTES
A. ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS, WHICH INCLUDE,
BUT ARE NOT LIMITED TO, THE OWNER - CONTRACTOR AGREEMENT, THE
PROJECT MANUAL (WHICH INCLUDES GENERAL AND SUPPLEMENTARY
CONDITIONS AND SPECIFICATIONS), DRAWINGS OF ALL DISCIPLINES AND ALL
ADDENDA, MODIFICATIONS AND CLARIFICATIONS ISSUED BY THE ARCHITECT /
ENGINEER.
B. CONTRACT DOCUMENTS SHALL BE ISSUED TO ALL SUBCONTRACTORS BY THE
GENERAL CONTRACTOR IN COMPLETE SETS IN ORDER TO ACHIEVE THE FULL
EXTENT AND COMPLETE COORDINATION OF ALL WORK. CONTRACTOR IS
RESPONSIBLE FOR COORDINATING AND CORRELATING QUANTITIES AND
DIMENSIONS.
C. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. NOTIFY
ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING
INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
D. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. NOTIFY ARCHITECT /
ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION
OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
E. DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE PROFILES AND TYPE
OF DETAILING REQUIRED THROUGHOUT THE WORK. DETAILS NOT SHOWN ARE
SIMILAR IN CHARACTER TO DETAILS SHOWN. WHERE SPECIFIC DIMENSIONS,
DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, NOTIFY ARCHITECT /
ENGINEER BEFORE PROCEEDING WITH THE WORK.
F. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED,
INSTALLED, CONNECTED, ERECTED, CLEANED AND CONDITIONED ACCORDING TO
MANUFACTURERS' INSTRUCTIONS. IN CASE OF DISCREPANCIES BETWEEN
MANUFACTURERS' INSTRUCTIONS AND THE CONTRACT DOCUMENTS, NOTIFY
ARCHITECT / ENGINEER BEFORE PROCEEDING WITH THE WORK.
G. LARGE-SCALE, MORE SPECIFIC DETAILS TAKE PRECEDENCE OVER
SMALLER-SCALE, LESS SPECIFIC DETAILS AND INFORMATION. MORE STRINGENT
REQUIREMENTS FOR CODE, PRODUCTS AND INSTALLATION TAKE PRECEDENCE
OVER LESS STRINGENT REQUIREMENTS. NOTIFY ARCHITECT/ENGINEER OF ANY
DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION OR CLARIFICATION
BEFORE PROCEEDING WITH THE WORK.
H. PROVIDE CONTINUOUS SEALANT AROUND ALL MATERIALS AT ALL INTERIOR AND
EXTERIOR WALL PENETRATIONS. REFER TO SPECIFICATIONS FOR APPROPRIATE
SEALANT.
I. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER
TO AVOID GALVANIC CORROSION.
J. SEAL ALL OPENINGS IN WALLS, FLOORS, CEILINGS, AND ROOFS, AROUND DUCTS,
PIPES, VENTS, TRAPS, CONDUIT AND ALL OTHER PENETRATIONS WITH FIRE
STOPPING AS SPECIFIED AND REQUIRED BY CODES. IF FIRE STOPPING IS NOT
REQUIRED AT PENETRATIONS PER CODE, SEAL WITH CONTINUOUS SEALANT.
K. PROVIDE TEMPORARY WALLS, ENCLOSURES, DUST SHIELDS AND WALK-OFF MATS
AS REQUIRED TO SEPARATE DEMOLITION AND CONSTRUCTION FROM EXISTING
BUILDING.
L. PROVIDE BRACING AND SHORING AS REQUIRED TO PROTECT EXISTING
STRUCTURE TO REMAIN. PROVIDE SECURE AND WEATHERPROOF ENCLOSURE OF
TEMPORARY OPENINGS IN EXTERIOR WALLS. PROTECT ALL BUILDING
COMPONENTS FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION.
M. RESTORE ALL EXISTING AREAS AFFECTED BY DEMOLITION AND RELATED NEW
CONSTRUCTION TO THEIR ORIGINAL CONDITION, INCLUDING BUT NOT LIMITED TO
WALLS, FLOORS, AND CEILINGS AND THEIR ASSOCIATED FINISHES.
N. PROVIDE SOLID WALL BACKING WITH METAL OR FIRE-RETARDANT WOOD
BLOCKING BEHIND DOOR HARDWARE SUCH AS WALL STOPS, BUMPERS, HOLD
OPENS, ETC. AND AT ALL ITEMS REQUIRING FASTENING THROUGH GYP BD. TO
BLOCKING
O. RENDERED IMAGES MAY NOT BE AN ACCURATE REPRESENTATION OF BUILDING
CONDITIONS, REFER TO PLANS AND DETAILS CONTAINED WITHIN FOR SCOPE OF
WORK.
SHEET INDEX
SHEET # SHEET TITLE
GENERAL
G1-10 TITLE SHEET, SHEET INDEX, PROJECT GENERAL NOTES
G1-12 MOUNTING HEIGHTS, ABBREVIATIONS AND SYMBOLS, HORIZONTAL
ASSEMBLIES
G2-20 FIRST AND SECOND FLOOR CODE PLANS AND CODE DATA
ARCHITECTURAL
A1-11 FIRST FLOOR DEMOLITION PLAN - OVERALL
A1-11A FIRST FLOOR DEMOLITION PLAN - AREA A
A1-11B FIRST AND SECOND FLOOR DEMOLITION PLAN - AREA B
A1-12 SECOND FLOOR DEMOLITION PLAN - OVERALL
A1-12A SECOND FLOOR DEMOLITION PLAN - AREA A
A1-13 FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL
A1-13A FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A
A1-13B FIRST AND SECOND FLOOR REFLECTED CEILING DEMOLITION PLANS -
AREA B
A1-14 SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL
A1-14A SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A
A1-21 FIRST FLOOR PLAN - OVERALL
A1-21A FIRST FLOOR PLAN - AREA A & DOOR SCHEDULE, DOOR AND FRAME
TYPES
A1-21B FIRST AND SECOND FLOOR PLAN - AREA B
A1-22 SECOND FLOOR PLAN - OVERALL
A1-22A SECOND FLOOR PLAN - AREA A
A1-31 FIRST FLOOR REFLECTED CEILING PLAN - OVERALL
A1-31A FIRST FLOOR REFLECTED CEILING PLAN - AREA A AND CEILING DETAILS
A1-31B FIRST AND SECOND FLOOR REFLECTED CEILING PLANS - AREA B
A1-32 SECOND FLOOR REFLECTED CEILING PLAN - OVERALL
A1-32A SECOND FLOOR REFLECTED CEILING PLAN - AREA A
A5-11 ENLARGED FLOOR PLANS
INTERIOR DESIGN
I1-21 FIRST FLOOR FINISH PLAN - OVERALL
I1-21A FIRST FLOOR FINISH PLAN - AREA A
I1-21B FIRST AND SECOND FLOOR FINISH PLAN - AREA B
I1-22 SECOND FLOOR FINISH PLAN - OVERALL
I1-22A SECOND FLOOR FINISH PLAN - AREA A
I1-41 FIRST FLOOR SIGNAGE PLAN - OVERALL
I1-41A FIRST FLOOR SIGNAGE PLAN - AREA A
I1-41B FIRST AND SECOND FLOOR SIGNAGE PLAN - AREA B
I1-42 SECOND FLOOR SIGNAGE PLAN - OVERALL
I1-42A SECOND FLOOR SIGNAGE PLAN - AREA A
I4-11 FINISH LEGENDS, SCHEDULES, AND DETAILS
PLUMBING
P2-12 FIRST FLOOR PLUMBING PLAN
P2-13 SECOND FLOOR PLUMBING PLAN
ELECTRICAL
E2-11A FIRST FLOOR POWER AND SYSTEMS PLAN - AREA A
E2-12A SECOND FLOOR POWER AND SYSTEMS PLAN - AREA A
E5-11 ELECTRICAL SYMBOLS, PANELBOARDS SCHEDULES
217 EAST 2ND STREET
SUITE 110
DES MOINES, IOWA 50309
PHONE: 515.243.9143
DES MOINES OFFICE
1" = 400'-0"2
CAMP DODGE VICINITY MAP
ESSIO
FO
NAL
A R
C H
IT
E
C
R
P D
E S
N E
CI
L
T
SIGNATURE
PRINTED SIGNATURE
DATE
LICENSE NUMBER LICENSE RENEWAL DATE
SEAL
WIO A
SHEETS COVERED BY THIS SEAL:
I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL
SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME
OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE
CHARGE. I AM A DULY LICENSED ARCHITECT UNDER THE
LAWS OF THE STATE OF IOWA.
ADAM W.
PULS
P23206 P23206 12/31/27
ADAM W. PULS
09/08/26
ESSIO
FO
NAL
A R
C H
IT
E
C
R
P D
E S
N E
CI
L
T
SIGNATURE
PRINTED SIGNATURE
DATE
LICENSE NUMBER LICENSE RENEWAL DATE
SEAL
WIO A
SHEETS COVERED BY THIS SEAL:
I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL
SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME
OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE
CHARGE. I AM A DULY LICENSED ARCHITECT UNDER THE
LAWS OF THE STATE OF IOWA.
GLADYS
PETERSEN
ARC08590 ARC08590 06/30/27
GLADYS PETERSEN
09/08/26
ESSIO
FO
NAL
A R
C H
IT
E
C
R
P D
E S
N E
CI
L
T
SIGNATURE
PRINTED SIGNATURE
DATE
LICENSE NUMBER LICENSE RENEWAL DATE
SEAL
WIO A
SHEETS COVERED BY THIS SEAL:
I HEREBY CERTIFY THAT THE PORTION OF THIS TECHNICAL
SUBMISSION DESCRIBED BELOW WAS PREPARED BY ME
OR UNDER MY DIRECT SUPERVISION AND RESPONSIBLE
CHARGE. I AM A DULY LICENSED ARCHITECT UNDER THE
LAWS OF THE STATE OF IOWA.
CASEY G.
LARSEN
P26594 P26594 12/31/26
CASEY G. LARSEN
09/08/26
G1-10
G1-12
G2-20
A1-11
A1-11A
A1-11B
A1-12
A1-12A
A1-13
A1-13A
A1-13B
A1-14
A1-14A
A1-21
A1-21A
A1-21B
A1-22
A1-22A
A1-31
A1-31A
A1-31B
A1-32
A1-32A
A5-11
I1-21
I1-21A
I1-21B
I1-22
I1-22A
I1-41
I1-41A
I1-41B
I1-42
I1-42A
I4-11
E2-11A
E2-12A
E5-11
1/2" = 1'-0"1
LOCATION MAP - ENLARGED
P2-12
P2-13
REVISION SCHEDULE
DATE DESCRIPTION BY
*U R
H
A D
A C
O M
P L
IA
N T
O N
L Y
M A
X
FLUSH VALVE
RIM
MOUNTING HEIGHTS AND STANDARDS
AMBULATORY STALL
PLAN VIEW
(GRAB BARS EA SIDE,
REFER TO WATER CLOSET -
SIDE WALL DETAIL
FOR CONFIGURATION)
36" CLEAR
M
IN
C L E
A R
WATER CLOSET
REAR WALL
WATER CLOSET
SIDE WALL
24" MIN 12" MIN
*WCC
*G B
H
24" MIN
42" MAX
7"-9"
M
IN
/2
M
IN
*G B
H
*V B
H
M
IN
12" MAX 42" MIN
*VBC
54" MIN
OPERABLE PARTS OF
DISPENSERS AND SANITARY
PRODUCT RECEPTACLES
SHALL BE LOCATED WITHIN
HATCHED AREA (ONLY
APPLICABLE FOR ADULT
RESTROOMS)
60" CLEAR FLOOR SPACE
*W C
S 4
M A
X
*T P
H
SANITARY PRODUCT
RECEPTACLE
ELECTRIC HAND
DRYER
TOP AT 2" MIN BELOW
HORIZONTAL GRAB BAR;
OPERABLE PARTS
WITHIN 12" MIN AND 40"
MAX FROM REAR WALL
FIXTURE CLEARANCES
DESCRIPTION
*GBH GRAB BAR HEIGHT
*TPH TOILET TISSUE DISPENSER HEIGHT
*WCC WATER CLOSET CENTER LINE
*WCS WATER CLOSET SEAT HEIGHT
*TSH TOP OF SINK OR COUNTER HEIGHT
*KCH KNEE CLEARANCE HEIGHT
*VBH VERTICAL GRAB BAR HEIGHT
*VBC VERTICAL GRAB BAR CENTERLINE
*HDH HIGH DRINKING FOUNTAIN SPOUT HEIGHT
*LDH LOW DRINKING FOUNTAIN SPOUT HEIGHT
*DSD DRINKING FOUNTAIN SPOUT DEPTH
FIXTURE GROUPS
*URH URINAL RIM HEIGHT
ADULTS (>12 YR)
33" - 36"
18" - 48"
17" - 18"
17" - 19"
34"
27"
39" - 41"
39" - 41"
38" - 43"
36"
5"
R1
ACCESSIBLE
NA
18" - 48"
16" - 18"
17" - 19"
34"
27"
NA
NA
38" - 43"
36"
5"
STANDARD
S
17" 24"
URINAL (ADA COMPLIANT ONLY)
WHEN TWO OR MORE URINALS ARE
SHOWN, MOUNT ONLY ONE AT ADA
COMPLIANT HEIGHT AND OTHERS
AT STANDARD RIM HEIGHT
REAR WALL GRAB BAR
OMITTED WITHIN
AMBULATORY STALLS
A
32" CLEAR MIN.
DOOR MUST
SWING OUT
M
IN
ADA COMPLIANT SIGNAGE
MULTIPLE LINE
ADA SIGNAGE
B O
T T
O M
L
IN
E O
F B
R A
IL
L E
M
IN
T
O B
O T
T O
M O
F
O F
R A
IS
E
D C
H A
R A
C T
E R
S
M
A X
T O
B O
T T
O M
O F
T O
P L
IN
E
O P
E R
A B
L E
P A
R T
T
O H
IG
H
E S
T
MATERIALS KEY
WOOD
SAND
STEEL
GRAVEL
GYPSUM BOARD
PLYWOOD
CONCRETE (SECTION)
GRANULAR FILL
EARTH
CMU (SECTION)
BATT INSULATION
BRICK
RIGID INSULATION
OR SHEATHING
SYNTHETIC STUCCO
TAGS AND SYMBOLS
SECTION
INTERIOR /
EXTERIOR
ELEVATION
DETAIL CALLOUT
AREA OF DETAIL
LEVEL 1
100'-0"
ELEVATION
DRAWING
TITLE
ABBREVIATIONS
SPRAY IN PLACE
INSULATION
VIEW NAME
1/8" = 1'-0"
A1-11
A1-11
SECTION NUMBER
SHEET NUMBER
A1-11
ELEVATION NUMBER
SHEET NUMBER
WELD SYMBOL
1/4 2-12
NOTES
COLUMN TYPE
CAP PLATE
BASE PLATE
COLUMN
??? 100' - 0"
SPOT
ELEVATION
DESCRIPTION
ELEVATION
DENOTES
ANNOTATION IS
REFERENCING
ANOTHER VIEW
*REFER TO ANSI FOR WELD
SYMBOL STANDARDS
C#
CP#
BP#
MOMENT
CONNECTION
SYMBOL
FOOTING STEP
BEAM SPLICE
SYMBOL
PIER TYPE
FOUNDATION
WALL TYPE
FOOTING TYPE
*REFER TO MOMENT
CONNECTION DETAILS
"S
DIRECTION OF
INSTALL
M1
P1
F1
FDN1
LEDGE STEP
FOOTING &
LEDGE STEP
NEW
CONSTRUCTION
GRIDS
EXISTING
CONSTRUCTION
GRIDS
1 1
B
A
WINDOW TYPE
EQUIPMENT TYPE A
MATERIAL TYPE
CASEWORK
TAG
FIN#
AL15
CDS
W#
H# D#
MOD LINE 1
MOD LINE 2
CDS CATALOG NUMBER FROM
NORTH AMERICAN
ARCHITECTURAL WOODWORK
STANDARDS (NAAWS)
(IF "M" IS INCLUDED SEE NOTE
BELOW FOR DESCRIPTION OF
MODIFICATION)
NOMINAL DEPTH
NOMINAL HEIGHT
NOMINAL WIDTH
DESCRIPTION OF MODIFICATION
FROM CDS CATALOG
FRAMING
TAG
18K W8X24 100'-0" (25) C=1" 15K
REACTION, TYPICAL
BOTH ENDS
MEMBER SIZE
NUMBER OF STUDS
CAMBER SIZE
WALL TYPE M12
SLAB TYPE SL#-9A
KEYNOTE TAG 3
DOOR NUMBERS 101
F1CEILING, FLOOR, OR
ROOF ASSEMBLY TYPE
ALT #
1/ A1-11
ALTERNATE
CALLOUT
DETAIL AND
SHEET NUMBER
ALTERNATE
NUMBER
MEMBER ELEVATION
SHEAR WALL
TAG
TYPE #
TYPE #
SHEAR WALL TAG
REACTION VALUE,
TYPICAL BOTH ENDS
HOLD DOWN TYPE,
TYPICAL BOTH ENDS
FLOOR
MATERIAL TYPE
F FIN#
SW#
SHEET NUMBER
DETAIL NUMBER
TRACK
ACOUSTICAL CEILING
TILE, REFER TO CEILING
PLANS AND INTERIOR
FINISH SCHEDULE
HANGER WIRE
DECK/ PLANK
ABOVE
SECTION
TRACK
ACOUSTICAL CEILING
TILE, REFER TO CEILING
PLANS AND INTERIOR
FINISH SCHEDULE
HANGER WIRE
DECK/ PLANK
ABOVE
SECTION
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:12:47 PM
G1-12
MOUNTING
HEIGHTS,
ABBREVIATIONS
AND SYMBOLS,
HORIZONTAL
ASSEMBLIES
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
G1-12 MOUNTING HEIGHTS, ABBREVIATIONS AND SYMBOLS, HORIZONTAL ASSEMBLIES
200 34920 G1-12
# POUND OR NUMBER
@ AT
ACP ACOUSTICAL CEILING PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADD ADDENDUM
ADDL ADDITIONAL
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
AWP ACOUSTICAL WALL PANEL
B BASE
BD BOARD
BL BROADLOOM CARPET
BLDG BUILDING
BO BOTTOM OF OR BY OWNER
BR BRICK
BRG BEARING
BSMT BASEMENT
C CONDUIT
CFS COLD FORMED STEEL
CG CORNER GUARD
CI CONTINUOUS INSULATION
CIP CAST IN PLACE
CJ CONTROL JOINT OR CONSTRUCTION JOINT
CL CENTERLINE
CLG CEILING
CLR CLEAR
CM CORRUGATED METAL
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUOUS
CPT CARPET
CR CHAIR RAIL
CRK CORK
CT TILE
CURT PRIVACY CURTAIN
CY CUBIC YARD
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DH DOOR HOLDER (MAGNETIC)
DIA DIAMETER
DLS DIMENSIONAL LETTER SIGNAGE
EA EACH
EC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
EIFS EXTERIOR INSULATION FINISH SYSTEM
ELEC ELECTRICAL
ELEV ELEVATION
EMERG EMERGENCY
ENCL ENCLOSURE
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EPX EPOXY
EQ EQUAL
EQUIP EQUIPMENT
ETC ETCETERA
EWC ELECTRIC WATER COOLER
EX EXISTING
EXP EXPANSION, EXPOSED
EXT EXTERIOR
F&I FURNISH AND INSTALL
FA FRESH AIR
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FBO FURNISHED BY OTHERS
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FLOOR FINISH
FFE FINISHED FLOOR ELEVATION
FRP FIBERGLASS REINFORCED PLASTIC
FRZ FREEZER
FS FLOOR SINK
FT FOOT OR FEET
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT INTERRUPT
GL GLAZING
GND GROUND
GYP GYPSUM
HD HUB DRAIN
HDG HOT DIP GALVANIZED
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HSA HEADED STUD ANCHOR
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
HVAC HEATING VENTILATION AND AIR CONDITIONING
ID INSIDE DIAMETER
IG ISOLATED GROUND
IMP INSULATED METAL PANEL
INFO INFORMATION
INP IN-PLACE
INSUL INSULATION
INT INTERIOR
J JUNCTION BOX
JAN JANITOR
JBE JOIST BEARING ELEVATION
JST JOIST
KES KITCHEN EQUIPMENT SUPPLIER
kW KILOWATT
LAV LAVATORY
LB POUND
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LN LINEAR
LVT LUXURY VINYL TILE
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MECH MECHANICAL
MEP MECHANICAL , ELECTRICAL, PLUMBING
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
MULL MULLION
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OH OVERHEAD
OHD OVERHEAD DOOR
OL OVERALL LENGTH
OPNG OPENING
ORD OVERFLOW ROOF DRAIN
OSB ORIENTED STRAND BOARD
PC PHOTO CELL, POLISHED CONCRETE
PLAM PLASTIC LAMINATE
PLWP PLASTIC LAMINATE WALL PANEL
PNT PAINT
PNT-#E EPOXY PAINT
POLYETH POLYETHYLENE
POLYISO POLYISOCYANURATE
PRV POWER ROOF VENTILATOR
PVC POLYVINYL CHLORIDE
QT QUARRY TILE
QTZ QUARTZ
RA RETURN AIR
RB RESILIENT BASE
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIGERATOR
REINF REINFORCED
REQD REQUIRED
RES RESINOUS FLOOR
REV REVISION / REVISED
RM ROOM
RO ROUGH OPENING
ROW / R/W RIGHT OF WAY
RP RESIN PANEL
RTE REFER TO ELEVATION
RTU ROOF TOP UNIT
SA SUPPLY AIR
SC SEALED CONCRETE
SF SQUARE FOOT
SIM SIMILAR
SM SURFACE MOUNTED
SPEC SPECIFICATION
SS SOLID SURFACE
SSTL STAINLESS STEEL
STD STANDARD
STN STONE
STOR STORAGE
SUSP SUSPENDED
SV SHEET VINYL
SY SQUARE YARDS
T&G TONGUE AND GROOVE
T&P TEMPERATURE AND PRESSURE
TB TACK BOARD
TBD TO BE DETERMINED
TD TRENCH DRAIN
TEC TECTUM
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TO TOP OF
TOF TOP OF FOOTING
TOL TOP OF LEDGE
TOS TOP OF STEEL
TOW TOP OF WALL
TR TAMPER RESISTANT
TS TUBE STEEL / THRESHOLD / TRANSITION STRIP
TV TELEVISION
TYP TYPICAL
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VEST VESTIBULE
VF VINYL FLOOR
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
VWP VENEER WALL PANEL
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WCG WALL COVERING
WD WOOD
WF WINDOW FILM
WG WALL GUARD
WH WALL HYDRANT
WHTR WATER HEATER
WP WEATHERPROOF
WT WINDOW TREATMENT
WWF WELDED WIRE FABRIC
XFMR TRANSFORMER
NOT TO SCALE
CEILING ASSEMBLY ACT-1
NOT TO SCALE
CEILING ASSEMBLY ACT-2
D
D
D D
W W
W W
W
D D
D
D D
D W
W W
W W
W
UP
UP
UP
WWWWWW
W W
W W
D D
D D
D D D D D D D
DN
DN
DN
DN
CODE DATA PLAN KEY
KB
EXIT
FIRE EXTINGUISHER
(NO WORK, EXISTING FE'S TO REMAIN)
FIRE EXTINGUISHER CABINET
(NO WORK, EXISTING FEC'S TO REMAIN)
FRONTAGE DISTANCE
KNOX BOX
FE
FEC
FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE
BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL
REQUIRED TO HAVE PROTECTED OPENINGS OR
PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY
IDENTIFIED WITH SIGNS OR STENCILING. SUCH
IDENTIFICATION SHALL:
1. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-
CEILING OR ATTIC SPACES
2. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL
AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED
HORIZONTALLY ALONG THE WALL OR PARTITION, AND
3. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT
WITH A MINIMUM 3/8" STROKE IN A CONTRASTING COLOR
INCORPORATING THE SUGGESTED WORDING "FIRE
AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS" OR
OTHER SIMILAR WORDING.
FIRE DEPARTMENT
CONNECTION
AED AUTOMATED EXTERNAL DEFIBRILLATOR
GENERAL CODE DATA
ADOPTED BUILDING CODES
UFC 1-200-01 UNIFIED FACILITIES CRITERIA (UFC) DEPARTMENT OF
DEFENSE BUILDING CODE
(BASED ON 2024 INTERNATIONAL BUILDING CODE)
2024 INTERNATIONAL BUILDING CODE AS ADOPTED BY IOWA
ADMINISTRATIVE RULE CHAPTERS 481-280 AND 481-301
2024 INTERNATIONAL FIRE CODE AS ADOPTED BY IOWA ADMINISTRATIVE
CHAPTER 481-280
2012 INTERNATIONAL ENERGY CONSERVATION CODE AS ADOPTED BY
IOWA ADMINISTRATIVE RULE CHAPTER 481-301
2012 NFPA 101 LIFE SAFETY CODE AS ADOPTED BY IOWA ADMINISTRATIVE
RULE CHAPTER 481-280
SMOKE ALARMS/DETECTORS AS ADOPTED BY IOWA ADMINISTRATIVE
RULE CHAPTER 481-280
CARBON MONOXIDE ALARMS AS ADOPTED BY IOWA ADMINISTRATIVE
RULE CHAPTER 481-280
STATE MECHANICAL CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC
HEALTH IOWA ADMINISTRATIVE RULE CHAPTER 481-426
STATE PLUMBING CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC
HEALTH IOWA ADMINISTRATIVE RULE CHAPTER 481-425
STATE ELECTRICAL CODE AS ADOPTED BY THE STATE ELECTRICAL
LICENSING BOARD IOWA ADMINISTRATIVE RULE CHAPTER 481-404
ACCESSIBILITY CODES AND STANDARDS
UFC 1-200-01 UNIFIED FACILITIES CRITERIA (UFC) DEPARTMENT OF
DEFENSE BUILDING CODE
(BASED ON 2024 INTERNATIONAL BUILDING CODE)
ABA STANDARDS AND DEPARTMENT OF DEFENSE POLICY MEMORANDUM
ACCESSIBILITY STANDARDS FOR DEPARTMENT OF DEFENSE FACILITIES
2010 AMERICANS WITH DISABILITIES ACT AS ADOPTED BY IOWA
ADMINISTRATIVE RULE CHAPTER 481-301
OCCUPANCY CLASSIFICATION AND USE
RESIDENTIAL R-1
FIRE PROTECTION SYSTEMS
NONSPRINKLERED
CONSTRUCTION TYPE
TYPE VB
EXISTING BUILDING ALTERATION: LEVEL 1 ALTERNATION
WORK IS LIMITED TO REPLACEMENT OF INTERIOR FINISHES, PLUMBING
FIXTURES, TOILET PARTITIONS, TOILET ACCESSORIES, COUNTERTOPS,
CEILING, SIGNAGE, AND RELATED INCIDENTAL WORK. NO CHANGE IN
OCCUPANCY CLASSIFICATION, OCCUPANT LOAD, BUILDING AREA,
BUILDING HEIGHT, MEANS OF EGRESS, OR FIRE-RESISTANCE-RATED
CONSTRUCTION IS PROPOSED. WORK IS CLASSIFIED AS A LEVEL 1
ALTERATION UNDER THE 2024 INTERNATIONAL EXISTING BUILDING CODE.
EXISTING LAWFUL CONDITIONS ARE PERMITTED TO REMAIN EXCEPT
WHERE SPECIFICALLY REQUIRED BY THE IEBC. NEW MATERIALS AND
ALTERED ELEMENTS SHALL COMPLY WITH THE CURRENTLY ADOPTED
CODES AND ACCESSIBILITY STANDARDS WITHIN THE SCOPE OF WORK.
3078 SF
DINING
858 SF
KITCHEN
99 SF
164E
STORAGE
KITCHEN
74 SF
164D
STORAGE
KITCHEN
33 SF
ENTRY
100 SF
OFFICE
30 SF
LATRINE
45 SF
ENTRY
122 SF
ELECTRICAL
141 SF
SCULLERY
634 SF
MECHANICAL
31 SF
JANITORIAL
320 SF
STORAGE
SUPPLY
515 SF
OFFICE
104 SF
OFFICE
331 SF
LAUNDRY
605 SF
LATRINE A
464 SF
LATRINE B
46 SF
JANITORIAL
1282 SF
CORRIDOR
211 SF
CORRIDOR
2146 SF
BARRACKS
A
2147 SF
BARRACKS
B
48 SF
ENTRY
1014 SF
DAY ROOM
48 SF
ENTRY
280 SF
LAUNDRY
555 SF
LATRINE D 376 SF
LATRINE C
25 SF
JANITORIAL
157 SF
CORRIDOR
2155 SF
BARRACKS
C
2125 SF
BARRACKS
D
74 SF
114A
STAIRS
74 SF
114B
STAIRS
>30 FT ALL
SIDES, TYP
MECHANICAL
LATRINE
MECHANICAL
VESTIBULE
CORRIDOR
VESTIBULE
BARRACK
BARRACK
703 SF
MECHANICAL
700 SF
LAUNDRY
2153 SF
BARRACKS
H
2142 SF
BARRACKS
G
448 SF
LATRINE H
2131 SF
BARRACKS
E
2165 SF
BARRACKS
F
379 SF
LATRINE G
468 SF
LATRINE F
493 SF
LATRINE E
201 SF
CORRIDOR
179 SF
CORRIDOR
540 SF
CORRIDOR
24 SF
JANITORIAL
46 SF
JANITORIAL
132 SF
CORRIDOR
172 SF
CORRIDOR
210 SF
CORRIDOR
254 SF
CORRIDOR
224 SF
CORRIDOR
287 SF
CORRIDOR
74 SF
114A
STAIRS
74 SF
114B
STAIRS
MECHANICAL
LATRINE
MECHANICAL
VESTIBULE
CORRIDOR
VESTIBULE
BARRACK
BARRACK
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
EXISTING RATED EXTERIOR
CONSTRUCTION TO REMAIN
EXISTING RATED INTERIOR
CONSTRUCTION TO REMAIN
CONTRACTOR TO VERIFY EXISTING RATED WALL
CONSTRUCTION IN FIELD AND REPORT ANY
DISCREPANCIES TO THE PROJECT ARCHITECT.
FLOOR PLAN LEGEND
SHADED REGION INDICATES AREA OF PLANS THAT
ARE NOT INCLUDED IN SCOPE OF WORK.
BUILDING A: 2026 FINISHES AND REPAIRS
• FINISH UPGRADES THROUGHOUT BUILDING
• REUSE EXISTING DUCTWORK
• MAINTAIN EXISTING RATED PARTITIONS BUILDING A: 1993 ORIGINAL CONSTRUCTION
GROUP R-1
TYPE V-B CONSTRUCTION
NON-SPRINKLED
2 STORIES
1ST FLOOR: 22,630 SF
2ND FLOOR: 17,150
BUILDING C: 2020 ADDITION (NO WORK THIS AREA)
GROUP R-1
TYPE V-B CONSTRUCTION
NFPA 13R AUTO SPRINKLER THROUGHOUT
2 STORIES
3,150 SF/FLOOR
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:12:53 PM
G2-20
FIRST AND
SECOND FLOOR
CODE PLANS AND
CODE DATA
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
G2-20 FIRST AND SECOND FLOOR CODE PLANS AND CODE DATA
200 34920 G2-20
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
1/16" = 1'-0"1
CODE DATA PLAN - FIRST FLOOR
1/16" = 1'-0"2
CODE DATA PLAN - SECOND FLOOR
KEYPLAN
A
B
NOT TO SCALE
CODE KEY PLAN
D
D D
W W
W W
W
D
D
D
D D
D W
W W
W W
W
UP
UP
DINING
KITCHEN
164E
STORAGE
KITCHEN
164D
STORAGE
KITCHEN
ENTRY
OFFICE
LATRINE
ENTRY
ELECTRICAL
SCULLERY
MECHANICAL
JANITORIAL
STORAGE
SUPPLY
OFFICE
OFFICE
LAUNDRY
LATRINE A
LATRINE B
JANITORIAL
CORRIDOR
CORRIDOR
BARRACKS
A
BARRACKS
B
ENTRY
DAY ROOM
ENTRY
LAUNDRY
LATRINE D 103
LATRINE C
JANITORIAL
CORRIDOR
BARRACKS
C
BARRACKS
D
114B
STAIRS
114A
STAIRS
LATRINE
MECHANICAL
CORRIDOR
BARRACK
BARRACK
MECHANICAL
VESTIBULE
VESTIBULE
FLOOR PLAN LEGEND
SHADED REGION INDICATES AREA OF PLANS THAT
ARE NOT INCLUDED IN SCOPE OF WORK.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:12:57 PM
A1-11
FIRST FLOOR
DEMOLITION
PLAN - OVERALL
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-11 FIRST FLOOR DEMOLITION PLAN - OVERALL
400 34920 A1-11
3/32" = 1'-0"1
FIRST FLOOR DEMOLITION PLAN - OVERALL
KEYPLAN
A
B
D
D D
W W
W W
W
D
D
D D
D D
W W
W W
W W
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
DEMOLITION
1/ A
1-
B
1/ A1-11B
DINING
KITCHEN
164E
STORAGE
KITCHEN
164D
STORAGE
KITCHEN
ENTRY
OFFICE
LATRINE
ENTRY
ELECTRICAL
SCULLERY
MECHANICAL
JANITORIAL
STORAGE
SUPPLY
OFFICE
OFFICE
LAUNDRY
LATRINE A
LATRINE B
JANITORIAL
CORRIDOR
CORRIDOR
BARRACKS
A
BARRACKS
B
ENTRY
DAY ROOM
ENTRY
LAUNDRY
LATRINE D
LATRINE C
JANITORIAL
CORRIDOR
BARRACKS
C
BARRACKS
D
114A
STAIRS
114B
STAIRS
D6
D6
D6
D2
D3
D2
D6
D3
D6
D4
D4
D1D1
D8
D8
D8
D8
D1D1
D2
D3
D4
D6
D6
D2
D4
D6
D3
D6
D9
D9
D9
D9
D9
D9
D11
D15 D15
D15 D15
D5
D5
D1 D1
D1 D1
DEMOLITION SHEET NOTES
A. EXISTING CONDITIONS SHOWN ON DRAWINGS REPRESENT
CURRENT BUILDING. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO EXAMINE THE DRAWINGS AND FIELD
VERIFY EXISTING CONDITIONS TO DETERMINE SCOPE OF
DEMOLITION WORK REQUIRED TO COMPLETE THE
REMODELING WORK INDICATED ON THE DRAWINGS PRIOR
TO PERFORMING WORK. ADDITIONAL WORK THAT IS
REQUIRED, WAS VISIBLE, AND COULD HAVE BEEN IDENTIFIED
DURING BIDDING SHALL BE COMPLETED BY THE
RESPONSIBLE TRADE CONTRACTOR(S) AT NO ADDITIONAL
COST TO THE OWNER.
B. REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR
REVIEW. WORK DONE WITHOUT RESOLUTION OF
DISCREPANCIES MUST BE REDONE AT THE REQUEST OF THE
ARCHITECT AT NO ADDITIONAL COST TO THE CONTRACT.
C. DEMOLITION OF ANY EXISTING CONSTRUCTION SHALL
INCLUDE WHAT IS NECESSARY AND REQUIRED TO
ACCOMMODATE THE REQUIREMENTS OF NEW
CONSTRUCTION.
D. CONTRACTOR TO BE RESPONSIBLE FOR PROTECTING ANY
LOOSE FURNISHINGS (CHAIRS, TABLES, DESKS, ETC.) AND
MOVING AS NEEDED. CONTRACTOR TO BE RESPONSIBLE
FOR DISCONNECTING ALL UTILITY CONNECTIONS TO
WASHING MACHINES AND DRYERS TO MOVE THE MACHINES
AS NECESSARY FOR PAINTING WORK.
E. VERIFY WITH OWNER FOR ITEMS TO BE SALVAGED BEFORE
STARTING DEMOLITION WORK.
F. CONSTRUCT DUST PROOF PARTITIONS TO SEPARATE AREAS
OF CONSTRUCTION FROM ADJACENT OCCUPIED AREAS
OUTSIDE SCOPE OF CONSTRUCTION.
G. REQUIRED MEANS OF EGRESS FROM THE BUILDING SHALL
BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION
WHEN THE BUILDING REMAINS OCCUPIED. IN THE EVENT
THAT AN EXISTING MEANS OF EGRESS CANNOT BE
MAINTAINED, THE GENERAL CONTRACTOR SHALL PROVIDE
AN APPROVED TEMPORARY MEANS OF EGRESS.
H. MAINTAIN THE INTEGRITY OF ALL EXISTING RATED
ELEMENTS, FIRE SEAL ANY PENETRATIONS WITH U.L.
APPROVED ASSEMBLY.
I. CONTRACTOR IS TO VERIFY THE EXACT LOCATION OF ALL
EXISTING UTILITIES PRIOR TO DEMOLITION ACTIVITIES.
J. DO NOT INTERRUPT EXISTING UTILITIES, EXCEPT WHEN
AUTHORIZED IN WRITING BY AHJ. PROVIDE TEMPORARY
SERVICES DURING INTERRUPTIONS TO EXISTING UTILITIES,
AS ACCEPTABLE TO GOVERNING AUTHORITIES.
K. WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED,
RELOCATED, OR ABANDONED, PROVIDE BYPASS
CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE
BEFORE PROCEEDING WITH REMOVAL.
L. PREP SURFACES FOR NEW FINISHES IN EVERY ROOM.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:00 PM
A1-11A
FIRST FLOOR
DEMOLITION
PLAN - AREA A
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-11A FIRST FLOOR DEMOLITION PLAN - AREA A
400 34920 A1-11A
1/8" = 1'-0"1
FIRST FLOOR DEMOLITION PLAN - AREA A
KEYPLAN
A
KEYNOTE LEGEND
D1 DEMOLISH ALL EXISTING BATHROOM PARTITIONS,
ACCESSORIES, AND MOUNTING HARDWARE.
D2 DEMOLISH ALL EXISTING PAPER TOWEL DISPENSERS AND
MOUNTING HARDWARE.
D3 DEMOLISH ALL EXISTING SINKS AND FAUCETS.
D4 DEMOLISH ALL EXISTING COUNTERTOPS, BACKSPLASH, AND
SUPPORT BRACKETS. REPAIR WALL AS REQUIRED FROM
DEMO OF TALL BACKSPLASH. PREP SURFACE FOR NEW
FINISHES.
D5 DEMOLISH EXISTING DOOR FRAME, DOOR PANEL, SIDELITES
AND ACCESSORIES. SAVE EXISTING HARDWARE TO REUSE
FOR NEW DOOR. PATCH AND REPAIR ADJACENT SURFACES AS
NECESSARY.
D6 DEMOLISH ALL EXISTING SOAP DISPENSERS AND MOUNTING
HARDWARE.
D8 DEMOLISH EXISTING WALL MOUNTED SHOWER BENCH.
PATCH/REPAIR WALL AS REQUIRED. PREP FOR NEW FINISHES.
D9 REMOVE ALL ROOM, WAYFINDING, AND DOOR NUMBER
SIGNAGE THROUGHOUT BUILDING. PATCH/REPAIR SURFACES
AS REQUIRED FOR NEW FINISHES.
D11 ALL EXISTING RESTROOM ACCESSORIES AND FIXTURES TO
REMAIN. REMOVE AND REINSTALL AS REQUIRED FOR
PAINTING WORK.
D15 EXISTING MIRRORS TO REMAIN. PROTECT DURING
CONSTRUCTION.
UP
DN
DN
DN
1/ A
1-
A
1/ A1-11A
ENTRY
LATRINE D
LATRINE C
JANITORIAL
CORRIDOR
BARRACKS
D
BARRACKS
D
BARRACKS
C
D8
MECHANICAL
LATRINE
MECHANICAL
VESTIBULE
CORRIDOR
VESTIBULE
BARRACK
BARRACK
D2
D3
D4
D6
D6
D2
D4
D6
D3
D6
D9
D7
D7
D15 D15
1/ A
1-
A
1/ A1-12A
BARRACKS
H
LATRINE H
LATRINE G
CORRIDOR
JANITORIAL
CORRIDOR
CORRIDOR
BARRACKS
G
MECHANICAL
LATRINE
MECHANICAL
VESTIBULE
VESTIBULE
CORRIDOR
BARRACK
BARRACK
D8D2 D2 D6
D4
D3
D6
D6
D4
D3
D6
D9
D9
D7
D7
D15
D15
D16 D16
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
DEMOLITION
DEMOLITION SHEET NOTES
A. EXISTING CONDITIONS SHOWN ON DRAWINGS REPRESENT
CURRENT BUILDING. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO EXAMINE THE DRAWINGS AND FIELD
VERIFY EXISTING CONDITIONS TO DETERMINE SCOPE OF
DEMOLITION WORK REQUIRED TO COMPLETE THE
REMODELING WORK INDICATED ON THE DRAWINGS PRIOR
TO PERFORMING WORK. ADDITIONAL WORK THAT IS
REQUIRED, WAS VISIBLE, AND COULD HAVE BEEN IDENTIFIED
DURING BIDDING SHALL BE COMPLETED BY THE
RESPONSIBLE TRADE CONTRACTOR(S) AT NO ADDITIONAL
COST TO THE OWNER.
B. REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR
REVIEW. WORK DONE WITHOUT RESOLUTION OF
DISCREPANCIES MUST BE REDONE AT THE REQUEST OF THE
ARCHITECT AT NO ADDITIONAL COST TO THE CONTRACT.
C. DEMOLITION OF ANY EXISTING CONSTRUCTION SHALL
INCLUDE WHAT IS NECESSARY AND REQUIRED TO
ACCOMMODATE THE REQUIREMENTS OF NEW
CONSTRUCTION.
D. CONTRACTOR TO BE RESPONSIBLE FOR PROTECTING ANY
LOOSE FURNISHINGS (CHAIRS, TABLES, DESKS, ETC.) AND
MOVING AS NEEDED. CONTRACTOR TO BE RESPONSIBLE
FOR DISCONNECTING ALL UTILITY CONNECTIONS TO
WASHING MACHINES AND DRYERS TO MOVE THE MACHINES
AS NECESSARY FOR PAINTING WORK.
E. VERIFY WITH OWNER FOR ITEMS TO BE SALVAGED BEFORE
STARTING DEMOLITION WORK.
F. CONSTRUCT DUST PROOF PARTITIONS TO SEPARATE AREAS
OF CONSTRUCTION FROM ADJACENT OCCUPIED AREAS
OUTSIDE SCOPE OF CONSTRUCTION.
G. REQUIRED MEANS OF EGRESS FROM THE BUILDING SHALL
BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION
WHEN THE BUILDING REMAINS OCCUPIED. IN THE EVENT
THAT AN EXISTING MEANS OF EGRESS CANNOT BE
MAINTAINED, THE GENERAL CONTRACTOR SHALL PROVIDE
AN APPROVED TEMPORARY MEANS OF EGRESS.
H. MAINTAIN THE INTEGRITY OF ALL EXISTING RATED
ELEMENTS, FIRE SEAL ANY PENETRATIONS WITH U.L.
APPROVED ASSEMBLY.
I. CONTRACTOR IS TO VERIFY THE EXACT LOCATION OF ALL
EXISTING UTILITIES PRIOR TO DEMOLITION ACTIVITIES.
J. DO NOT INTERRUPT EXISTING UTILITIES, EXCEPT WHEN
AUTHORIZED IN WRITING BY AHJ. PROVIDE TEMPORARY
SERVICES DURING INTERRUPTIONS TO EXISTING UTILITIES,
AS ACCEPTABLE TO GOVERNING AUTHORITIES.
K. WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED,
RELOCATED, OR ABANDONED, PROVIDE BYPASS
CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE
BEFORE PROCEEDING WITH REMOVAL.
L. PREP SURFACES FOR NEW FINISHES IN EVERY ROOM.
FLOOR PLAN LEGEND
SHADED REGION INDICATES AREA OF PLANS THAT
ARE NOT INCLUDED IN SCOPE OF WORK.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:10 PM
A1-11B
FIRST AND
SECOND FLOOR
DEMOLITION
PLAN - AREA B
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-11B FIRST AND SECOND FLOOR DEMOLITION PLAN - AREA B
400 34920 A1-11B
1/8" = 1'-0"1
FIRST FLOOR DEMOLITION PLAN - AREA B
KEYPLAN
B
1/8" = 1'-0"2
SECOND FLOOR DEMOLITION PLAN - AREA B
KEYNOTE LEGEND
D2 DEMOLISH ALL EXISTING PAPER TOWEL DISPENSERS AND
MOUNTING HARDWARE.
D3 DEMOLISH ALL EXISTING SINKS AND FAUCETS.
D4 DEMOLISH ALL EXISTING COUNTERTOPS, BACKSPLASH, AND
SUPPORT BRACKETS. REPAIR WALL AS REQUIRED FROM
DEMO OF TALL BACKSPLASH. PREP SURFACE FOR NEW
FINISHES.
D6 DEMOLISH ALL EXISTING SOAP DISPENSERS AND MOUNTING
HARDWARE.
D7 REMOVE DOOR ALARM SIGNAGE FOR PAINTING. SALVAGE FOR
REINSTALLATION.
D8 DEMOLISH EXISTING WALL MOUNTED SHOWER BENCH.
PATCH/REPAIR WALL AS REQUIRED. PREP FOR NEW FINISHES.
D9 REMOVE ALL ROOM, WAYFINDING, AND DOOR NUMBER
SIGNAGE THROUGHOUT BUILDING. PATCH/REPAIR SURFACES
AS REQUIRED FOR NEW FINISHES.
D15 EXISTING MIRRORS TO REMAIN. PROTECT DURING
CONSTRUCTION.
D16 DEMOLISH SIGNAGE FOR FLUSHING INFORMATION AT TOILET
PARTITION AND URINAL.
WWWWWW
W W
W W
D D
D D
D D D D D D D
DN
DN
DN
LAUNDRY
MECHANICAL
CORRIDOR
CORRIDOR
LATRINE E
LATRINE F
CORRIDOR
CORRIDOR
CORRIDOR
BARRACKS
E
BARRACKS
F
LATRINE H 201
LATRINE G
CORRIDOR
CORRIDOR
CORRIDOR
BARRACKS
H
BARRACKS
G
JANITORIAL
JANITORIAL
114A
STAIRS
114B
STAIRS
FLOOR PLAN LEGEND
SHADED REGION INDICATES AREA OF PLANS THAT
ARE NOT INCLUDED IN SCOPE OF WORK.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:15 PM
A1-12
SECOND FLOOR
DEMOLITION
PLAN - OVERALL
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-12 SECOND FLOOR DEMOLITION PLAN - OVERALL
400 34920 A1-12
3/32" = 1'-0"1
SECOND FLOOR DEMOLITION PLAN - OVERALL
KEYPLAN
A
B
W
W W
D D
D D
D D D D D D D
2/ A
1-
B
2/ A1-11B
LATRINE H
LATRINE G
CORRIDOR
CORRIDOR
JANITORIAL
CORRIDOR
CORRIDOR
CORRIDOR
BARRACKS
G
BARRACKS
H
MECHANICAL
LAUNDRY
BARRACKS
E
BARRACKS
F
LATRINE F
LATRINE E
CORRIDOR
JANITORIAL
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
114A
STAIRS
114B
STAIRS
D8
D8
D8
D8
D6
D4
D6
D3
D1D1
D6
D3
D4
D6
D1 D1
D2 D2 D6
D4
D3
D6
D6
D4
D3
D6
D9
D9
D9
D9
D9
D9
D9
D15
D15
D15
D15
D1D1
D1D1
D2D2
D16
D16
D16
D16 D16
D16
D16
D16
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
DEMOLITION
DEMOLITION SHEET NOTES
A. EXISTING CONDITIONS SHOWN ON DRAWINGS REPRESENT
CURRENT BUILDING. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO EXAMINE THE DRAWINGS AND FIELD
VERIFY EXISTING CONDITIONS TO DETERMINE SCOPE OF
DEMOLITION WORK REQUIRED TO COMPLETE THE
REMODELING WORK INDICATED ON THE DRAWINGS PRIOR
TO PERFORMING WORK. ADDITIONAL WORK THAT IS
REQUIRED, WAS VISIBLE, AND COULD HAVE BEEN IDENTIFIED
DURING BIDDING SHALL BE COMPLETED BY THE
RESPONSIBLE TRADE CONTRACTOR(S) AT NO ADDITIONAL
COST TO THE OWNER.
B. REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR
REVIEW. WORK DONE WITHOUT RESOLUTION OF
DISCREPANCIES MUST BE REDONE AT THE REQUEST OF THE
ARCHITECT AT NO ADDITIONAL COST TO THE CONTRACT.
C. DEMOLITION OF ANY EXISTING CONSTRUCTION SHALL
INCLUDE WHAT IS NECESSARY AND REQUIRED TO
ACCOMMODATE THE REQUIREMENTS OF NEW
CONSTRUCTION.
D. CONTRACTOR TO BE RESPONSIBLE FOR PROTECTING ANY
LOOSE FURNISHINGS (CHAIRS, TABLES, DESKS, ETC.) AND
MOVING AS NEEDED. CONTRACTOR TO BE RESPONSIBLE
FOR DISCONNECTING ALL UTILITY CONNECTIONS TO
WASHING MACHINES AND DRYERS TO MOVE THE MACHINES
AS NECESSARY FOR PAINTING WORK.
E. VERIFY WITH OWNER FOR ITEMS TO BE SALVAGED BEFORE
STARTING DEMOLITION WORK.
F. CONSTRUCT DUST PROOF PARTITIONS TO SEPARATE AREAS
OF CONSTRUCTION FROM ADJACENT OCCUPIED AREAS
OUTSIDE SCOPE OF CONSTRUCTION.
G. REQUIRED MEANS OF EGRESS FROM THE BUILDING SHALL
BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION
WHEN THE BUILDING REMAINS OCCUPIED. IN THE EVENT
THAT AN EXISTING MEANS OF EGRESS CANNOT BE
MAINTAINED, THE GENERAL CONTRACTOR SHALL PROVIDE
AN APPROVED TEMPORARY MEANS OF EGRESS.
H. MAINTAIN THE INTEGRITY OF ALL EXISTING RATED
ELEMENTS, FIRE SEAL ANY PENETRATIONS WITH U.L.
APPROVED ASSEMBLY.
I. CONTRACTOR IS TO VERIFY THE EXACT LOCATION OF ALL
EXISTING UTILITIES PRIOR TO DEMOLITION ACTIVITIES.
J. DO NOT INTERRUPT EXISTING UTILITIES, EXCEPT WHEN
AUTHORIZED IN WRITING BY AHJ. PROVIDE TEMPORARY
SERVICES DURING INTERRUPTIONS TO EXISTING UTILITIES,
AS ACCEPTABLE TO GOVERNING AUTHORITIES.
K. WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED,
RELOCATED, OR ABANDONED, PROVIDE BYPASS
CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE
BEFORE PROCEEDING WITH REMOVAL.
L. PREP SURFACES FOR NEW FINISHES IN EVERY ROOM.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:17 PM
A1-12A
SECOND FLOOR
DEMOLITION
PLAN - AREA A
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-12A SECOND FLOOR DEMOLITION PLAN - AREA A
400 34920 A1-12A
1/8" = 1'-0"1
SECOND FLOOR DEMOLITION PLAN - AREA A
KEYPLAN
A
KEYNOTE LEGEND
D1 DEMOLISH ALL EXISTING BATHROOM PARTITIONS,
ACCESSORIES, AND MOUNTING HARDWARE.
D2 DEMOLISH ALL EXISTING PAPER TOWEL DISPENSERS AND
MOUNTING HARDWARE.
D3 DEMOLISH ALL EXISTING SINKS AND FAUCETS.
D4 DEMOLISH ALL EXISTING COUNTERTOPS, BACKSPLASH, AND
SUPPORT BRACKETS. REPAIR WALL AS REQUIRED FROM
DEMO OF TALL BACKSPLASH. PREP SURFACE FOR NEW
FINISHES.
D6 DEMOLISH ALL EXISTING SOAP DISPENSERS AND MOUNTING
HARDWARE.
D8 DEMOLISH EXISTING WALL MOUNTED SHOWER BENCH.
PATCH/REPAIR WALL AS REQUIRED. PREP FOR NEW FINISHES.
D9 REMOVE ALL ROOM, WAYFINDING, AND DOOR NUMBER
SIGNAGE THROUGHOUT BUILDING. PATCH/REPAIR SURFACES
AS REQUIRED FOR NEW FINISHES.
D15 EXISTING MIRRORS TO REMAIN. PROTECT DURING
CONSTRUCTION.
D16 DEMOLISH SIGNAGE FOR FLUSHING INFORMATION AT TOILET
PARTITION AND URINAL.
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
F
WS
F
W S
A A
DINING
KITCHEN
164E
STORAGE
KITCHEN
164D
STORAGE
KITCHEN
ENTRY
OFFICE
LATRINE
ENTRY
ELECTRICAL
SCULLERY
MECHANICAL
JANITORIAL
STORAGE
SUPPLY
OFFICE
OFFICE
LAUNDRY
LATRINE A
LATRINE B
JANITORIAL
CORRIDOR
CORRIDOR
BARRACKS
A
BARRACKS
B
ENTRY
DAY ROOM
ENTRY
LAUNDRY
LATRINE D 103
LATRINE C
JANITORIAL
CORRIDOR
BARRACKS
C
BARRACKS
D
114B
STAIRS
114A
STAIRS
LATRINE
MECHANICAL
CORRIDOR
BARRACK
BARRACK
MECHANICAL
VESTIBULE
VESTIBULE
FLOOR PLAN LEGEND
SHADED REGION INDICATES AREA OF PLANS THAT
ARE NOT INCLUDED IN SCOPE OF WORK.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:22 PM
A1-13
FIRST FLOOR
REFLECTED
CEILING
DEMOLITION
PLAN - OVERALL
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-13 FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL
400 34920 A1-13
3/32" = 1'-0"1
FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL
KEYPLAN
A
B
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
F
WS
F
W S
A A
164E
STORAGE
KITCHEN
164D
STORAGE
KITCHEN
KITCHEN
ENTRY
LATRINE
OFFICE
ENTRY
STORAGE
SUPPLY
DINING
SCULLERY
ELECTRICAL
JANITORIAL
MECHANICAL
OFFICE
OFFICE
LAUNDRY
LATRINE A
LATRINE B
CORRIDOR
BARRACKS
A
BARRACKS
B
DAY ROOM
CORRIDOR
LAUNDRY
LATRINE D
LATRINE C
CORRIDOR
ENTRY
JANITORIAL
JANITORIAL
ENTRY
D10
D10
D10
D10
D10
D12
BARRACKS
C
BARRACKS
D
D14 D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D13 D13
D13 D13 D13 D13 D13 D13
D13
D13
D13
D13 D13 D13
D13
D13
D13D13D13
D14D14
D14
D14
D14
D14
D14
D14
1/ A1-13B
1/ A
1-
B
D14
D14 D14
D14 D14
D14
D18
D18
CEILING DEMOLITION SHEET NOTES
A. REPAIR CRACKING, HOLES, DEFECTS, ETC. AT ALL EXISTING GYPSUM
BOARD CEILINGS IN ROOMS THAT WORK IS OCCURRING.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:24 PM
A1-13A
FIRST FLOOR
REFLECTED
CEILING
DEMOLITION
PLAN - AREA A
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-13A FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A
400 34920 A1-13A
1/8" = 1'-0"1
FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A
KEYPLAN
A
KEYNOTE LEGEND
17 EXISTING CEILING TO REMAIN. DO NOT PAINT CEILING. NO
ADDITIONAL WORK REQUIRED.
D10 DEMO/REMOVE ACOUSTIC CEILING TILE AND GRID IN ITS
ENTIRETY. EXISTING LIGHTING AND MECHANICAL
EQUIPMENT (SUPPLY/RETURN GRILLES) TO BE REUSED.
REMOVE AND SALVAGE FOR REINSTALLATION.
D12 DEMOLISH EXISTING ACOUSTIC CEILING TILE BULKHEAD &
SOFFIT. DEMOLISH EXISTING CEILING GRID AND/OR
FRAMING AROUND MECHANICAL/PLUMBING EQUIPMENT,
PAINT EQUIPMENT TO MATCH ADJACENT WALL COLOR.
REFER TO FINISH PLANS.
D13 REMOVE EXISTING WINDOW TREATMENTS. SALVAGE FOR
REUSE.
D14 REPAIR ALL EXISTING CRACKING IN GYPSUM BOARD
CEILING. PREPARE FOR NEW PAINT. REFER TO FINISH PLANS
AND REFLECTED CEILING PLANS.
D18 REPAIR ANY CRACKING IN EXISTING PRECAST PANEL
CEILING. PREPARE FOR NEW PAINT. REFER TO FINISH PLANS
AND REFLECTED CEILING PLANS.
S
S
S
S
S
S
S
S
S
S
BARRACKS
D
BARRACKS
C
CORRIDOR
LATRINE D
LATRINE D
LATRINE C
LATRINE C
CORRIDOR
ENTRY
JANITORIAL
BARRACK
BARRACK
CORRIDOR
VESTIBULE
VESTIBULE
MECHANICAL
LATRINE
1/ A
1-
A
1/ A1-13A
D18
D18
BARRACKS
H
BARRACKS
G
LATRINE H
LATRINE H
LATRINE G
LATRINE G
CORRIDOR
CORRIDOR
CORRIDOR
LATRINE
MECHANICAL
CORRIDOR
VESTIBULE
VESTIBULE
BARRACK
BARRACK
JANITORIAL
1/ A1-14A
1/ A
1-
A
D14
D14
FLOOR PLAN LEGEND
SHADED REGION INDICATES AREA OF PLANS THAT
ARE NOT INCLUDED IN SCOPE OF WORK.
CEILING DEMOLITION SHEET NOTES
A. REPAIR CRACKING, HOLES, DEFECTS, ETC. AT ALL EXISTING GYPSUM
BOARD CEILINGS IN ROOMS THAT WORK IS OCCURRING.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:33 PM
A1-13B
FIRST AND
SECOND FLOOR
REFLECTED
CEILING
DEMOLITION
PLANS - AREA B
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-13B FIRST AND SECOND FLOOR REFLECTED CEILING DEMOLITION PLANS - AREA B
400 34920 A1-13B
1/8" = 1'-0"1
FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA B
1/8" = 1'-0"2
SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA B
KEYPLAN
B
KEYNOTE LEGEND
D14 REPAIR ALL EXISTING CRACKING IN GYPSUM BOARD
CEILING. PREPARE FOR NEW PAINT. REFER TO FINISH
PLANS AND REFLECTED CEILING PLANS.
D18 REPAIR ANY CRACKING IN EXISTING PRECAST PANEL
CEILING. PREPARE FOR NEW PAINT. REFER TO FINISH
PLANS AND REFLECTED CEILING PLANS.
S
S
S
S
S
S
S
S
S
S
S
S
S
S F
WS
FLOOR PLAN LEGEND
SHADED REGION INDICATES AREA OF PLANS THAT
ARE NOT INCLUDED IN SCOPE OF WORK.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:37 PM
A1-14
SECOND FLOOR
REFLECTED
CEILING
DEMOLITION
PLAN - OVERALL
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-14 SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL
400 34920 A1-14
3/32" = 1'-0"1
SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - OVERALL
KEYPLAN
A
B
S
S
S
S
S
S
S
S
S
S
S
S
F
WS
MECHANICAL
LAUNDRY
BARRACKS
H
BARRACKS
G
LATRINE H
BARRACKS
E
BARRACKS
F
LATRINE G
LATRINE F
LATRINE E
CORRIDOR
CORRIDOR
CORRIDOR
JANITORIAL
JANITORIAL
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
114A
STAIRS
114B
STAIRS
D14
D14 D14
D14 D14
D14D14
D14
D14 D14
D14
D14
D14
D14
2/ A1-13B
2/ A
1-
B
D14
D14
D14
D14
D14
D14 D14
D14
D14
D14
D14
D14
D14 D14
D14
D14
D14
D14
CEILING DEMOLITION SHEET NOTES
A. REPAIR CRACKING, HOLES, DEFECTS, ETC. AT ALL EXISTING GYPSUM
BOARD CEILINGS IN ROOMS THAT WORK IS OCCURRING.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:40 PM
A1-14A
SECOND FLOOR
REFLECTED
CEILING
DEMOLITION
PLAN - AREA A
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-14A SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A
400 34920 A1-14A
1/8" = 1'-0"1
SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA A
KEYPLAN
A
KEYNOTE LEGEND
17 EXISTING CEILING TO REMAIN. DO NOT PAINT CEILING. NO
ADDITIONAL WORK REQUIRED.
D14 REPAIR ALL EXISTING CRACKING IN GYPSUM BOARD
CEILING. PREPARE FOR NEW PAINT. REFER TO FINISH
PLANS AND REFLECTED CEILING PLANS.
D
D D
W W
W W
W
D
D
D
D D
D W
W W
W W
W
UP
UP
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION
FLOOR PLAN SHEET NOTES
• ALL WALL MOUNTED ITEMS TO SIT FLUSH ON A WALL
SURFACE. IN INSTANCES WHERE A WALL MOUNTED ITEM IS
TO BE INSTALLED ON TWO DIFFERENT FINISH
THICKNESSES, PROVIDE A HARDBOARD BACKER FOR THE
ITEM TO SIT FLUSH. PROVIDE SEALANT AROUND ALL EDGES
OF BACKER AND PAINT TO MATCH ADJACENT SURFACE
164E
STORAGE
KITCHEN
164D
STORAGE
KITCHEN
KITCHEN
ENTRY
LATRINE
OFFICE
ENTRY
DINING
ELECTRICAL
SCULLERY
JANITORIAL
MECHANICAL
STORAGE
SUPPLY
OFFICE
OFFICE
LAUNDRY
LATRINE A
LATRINE B
CORRIDOR
CORRIDOR
BARRACKS
A
BARRACKS
B
DAY ROOM
LAUNDRY
LATRINE D 103
LATRINE C
CORRIDOR
BARRACKS
D
BARRACKS
C
114B
STAIRS
114A
STAIRS
HM2
BARRACK
BARRACK
CORRIDOR
LATRINE
MECHANICAL
VESTIBULE
VESTIBULE
MECHANICAL
FLOOR PLAN LEGEND
SHADED REGION INDICATES AREA OF PLANS THAT
ARE NOT INCLUDED IN SCOPE OF WORK.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:45 PM
A1-21
FIRST FLOOR
PLAN - OVERALL
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-21 FIRST FLOOR PLAN - OVERALL
400 34920 A1-21
3/32" = 1'-0"1
FIRST FLOOR PLAN - OVERALL
KEYPLAN
A
B
D
D D
W W
W W
W
D
D
D
D D
D W
W W
W W
W
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION
FLOOR PLAN SHEET NOTES
• ALL WALL MOUNTED ITEMS TO SIT FLUSH ON A WALL
SURFACE. IN INSTANCES WHERE A WALL MOUNTED ITEM IS
TO BE INSTALLED ON TWO DIFFERENT FINISH
THICKNESSES, PROVIDE A HARDBOARD BACKER FOR THE
ITEM TO SIT FLUSH. PROVIDE SEALANT AROUND ALL EDGES
OF BACKER AND PAINT TO MATCH ADJACENT SURFACE
1/ A
1-
B
1/ A1-21B
A5-11
LATRINE D
LATRINE C
164E
STORAGE
KITCHEN
164D
STORAGE
KITCHEN
ENTRY
KITCHEN
LATRINE
OFFICE
ENTRY
DINING
STORAGE
SUPPLY
OFFICE
OFFICE
SCULLERY
ELECTRICAL
MECHANICAL
BARRACKS
A
BARRACKS
B
CORRIDOR
LATRINE A
LATRINE B
LAUNDRY
ENTRY
DAY ROOM
CORRIDOR
LAUNDRY
ENTRY
CORRIDOR
JANITORIAL
JANITORIAL
JANITORIAL
114B
STAIRS
114A
STAIRS
HM1
HM2
A
BARRACKS
D
BARRACKS
C
B
DOOR TYPES
FG1
FULL GLASS W/
CENTER RAIL
8" 8"
FRG-1
FRG-1
METAL FRAME
FRAME TYPES
2"
WIDTH
DOOR 2"
D
O O
R H
E
IG
H T
REUSE EXISTING DOOR
HARDWARE FOR NEW DOOR
FRG-1
2"1' - 8"2"
WIDTH
DOOR2"
5' - 2"
D O
O R
H E
IG
H
T
REUSE EXISTING DOOR
HARDWARE FOR NEW DOOR
FRG-1
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:48 PM
A1-21A
FIRST FLOOR
PLAN - AREA A &
DOOR SCHEDULE,
DOOR AND FRAME
TYPES
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-21A FIRST FLOOR PLAN - AREA A & DOOR SCHEDULE, DOOR AND FRAME TYPES
400 34920 A1-21A
1/8" = 1'-0"1
FIRST FLOOR PLAN - AREA A
KEYPLAN
A
GLAZING SCHEDULE
MARK MATERIAL THICKNESS COMMENTS
OTHER
FRG-1 FIRE RESISTANCE
RATED GLAZING UNIT
DOOR SCHEDULE
MARK ROOM NAME WIDTH HEIGHT
PANEL
THICKNESS
DOOR
TYPE DOOR MATERIAL
FRAME
TYPE FRAME MATERIAL
FIRE
RATING
HARDWARE
GROUP COMMENTS
156A ENTRY 3' - 0" 7' - 10" 0' - 1 3/4" FG1 HOLLOW METAL 1 HOLLOW METAL 60 MIN REUSE DOOR HARDWARE
156B ENTRY 3' - 0" 7' - 10" 0' - 1 3/4" FG1 HOLLOW METAL 1 HOLLOW METAL 60 MIN REUSE DOOR HARDWARE
HM1 HM2
DN
DN
DN
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION
FLOOR PLAN SHEET NOTES
• ALL WALL MOUNTED ITEMS TO SIT FLUSH ON A WALL
SURFACE. IN INSTANCES WHERE A WALL MOUNTED ITEM IS
TO BE INSTALLED ON TWO DIFFERENT FINISH
THICKNESSES, PROVIDE A HARDBOARD BACKER FOR THE
ITEM TO SIT FLUSH. PROVIDE SEALANT AROUND ALL EDGES
OF BACKER AND PAINT TO MATCH ADJACENT SURFACE
1/ A1-21A
1/ A
1-
A
LATRINE D
LATRINE C
BARRACKS
D
BARRACKS
C
ENTRY
CORRIDOR
JANITORIAL
MECHANICAL
LATRINE
MECHANICAL
VESTIBULE
CORRIDOR
VESTIBULE
BARRACK
BARRACK
1/ A
1-
A
1/ A1-22A
BARRACKS
H
BARRACKS
G
CORRIDOR
LATRINE H
LATRINE G
CORRIDOR
CORRIDOR
JANITORIAL
MECHANICAL
VESTIBULE
CORRIDOR
LATRINE
VESTIBULE
MECHANICAL
BARRACK
BARRACK
FLOOR PLAN LEGEND
SHADED REGION INDICATES AREA OF PLANS THAT
ARE NOT INCLUDED IN SCOPE OF WORK.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:13:58 PM
A1-21B
FIRST AND
SECOND FLOOR
PLAN - AREA B
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-21B FIRST AND SECOND FLOOR PLAN - AREA B
400 34920 A1-21B
1/8" = 1'-0"1
FIRST FLOOR PLAN - AREA B
1/8" = 1'-0"2
SECOND FLOOR PLAN - AREA B
KEYPLAN
B
W
W W
D D
D D
D D D D D D D
DN
DN
DN
LAUNDRY
MECHANICAL
CORRIDOR
CORRIDOR
LATRINE E
LATRINE F
CORRIDOR
CORRIDOR
CORRIDOR
BARRACKS
E
BARRACKS
F
LATRINE H 201
LATRINE G
CORRIDOR
CORRIDOR
CORRIDOR
BARRACKS
H
BARRACKS
G
JANITORIAL
JANITORIAL
114A
STAIRS
114B
STAIRS
FLOOR PLAN LEGEND
SHADED REGION INDICATES AREA OF PLANS THAT
ARE NOT INCLUDED IN SCOPE OF WORK.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
9/8/2026 3:14:02 PM
A1-22
SECOND FLOOR
PLAN - OVERALL
IOWA ARMY
NATIONAL GUARD
CAMP DODGE, JOHNSTON IOWA
34920 Arch R26
MJT
GMP
09/08/26
GMP
19083733
26-34920
S54 FINISH
UPGRADES
A1-22 SECOND FLOOR PLAN - OVERALL
400 34920 A1-22
3/32" = 1'-0"1
SECOND FLOOR PLAN - OVERALL
KEYPLAN
A
B
W
W W
D D
D D
D D D D D D D
2/ A
1-
B
2/ A1-21B
A5-11
CORRIDOR
LATRINE H
LATRINE G
BARRACKS
E
BARRACKS
F
LAUNDRY
MECHANICAL
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
LATRINE E
LATRINE F
JANITORIAL
JANITORIAL
BARRACKS
H
BARRACKS
G
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION
FLOOR PLAN SHEET NOTES
• ALL WALL MOUNTED ITEMS TO SIT FLUSH ON A WALL
SURFACE. IN INSTANCES WHERE A WALL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .