Attach_21_Decon_of_Patient_in_Training_Building_Medical_Room.pdf

PDF 341 KB Posted

Attached to
Medical Support Services for the Center for Domestic Preparedness
Solicitation number
HSFE20-15-R-0012
Issued by

About this file

Attachment 21

View the file

Other files

File Type Posted
HSFE20-15-R-0012_A00004.pdf PDF
HSFE20-15-R-0012_A00003.pdf PDF
HSFE20-15-R-0012_Questions_and_Answers.docx DOCX document
HSFE20-15-R-0012_B.2_Cost_Price_Schedule.docx DOCX document
Attach_35_Proficiency_Testing.pdf PDF
HSFE20-15-R-0012_A00002.pdf PDF
HSFE20-15-R-0012_A00001.docx DOCX document
Attach_11_COBRATF_Incident_Management_Manual.pdf PDF
Attach_30_Quality_Assurance_Program.pdf PDF
Attach_9_List_of_Reports_or_Deliverables.pdf PDF
Attach_6_Workplace_Attire_Policy.pdf PDF
Attach_29_Operation_of_Model_445_and_555_PH_Meter.pdf PDF
Attach_8_Accident-Incident_Reporting_Procedures.pdf PDF
Attach_36_Occupational_Health_Procedures.pdf PDF
Attach_12_GFP-GFE.pdf PDF
Attach_26_Operation_of_Dual_Syringe_Diluter.pdf PDF
Attach_39_Student_Medical_Notification.pdf PDF
Attach_37_CERP_Guidelines.pdf PDF
Attach_34_Data_Entry_Into_the_CRL_Database.pdf PDF
Attach_18_Course_Schedule_Exhibit_for_Non-COBRATF_Training.pdf PDF
Attach_19_Course_Schedule_Exhibit_COBRATF_Training.pdf PDF
HSFE20-15-R-0012_(Solicitation).pdf PDF
Attach_23_Transportation_of_Biohazardous_Trash.pdf PDF
Attach_1_Performance_Work_Statement.pdf PDF
Attach_28_Operation_of_Precision_Circulating_Water_Bath.pdf PDF
Attach_3_SCA_Wage_Determination.pdf PDF
Attach_20_Chem_Surety_Program_Standards_Document.pdf PDF
Attach_16_Student_Medical_Forms.pdf PDF
Attach_35_Proficiency_Testing.pdf PDF
Attach_17_FY_2015_Training_Calendar_Exhibit.pdf PDF
Attach_22_DuoDote_Auto_Injector.pdf PDF
Attach_7_Workplace_Safety_and_Health_Policy.pdf PDF
Attach_38_Consumables_Exhibit.pdf PDF
Attach_10_EOP_COOP_Plan.pdf PDF
Attach_25_Seventeen_Minute_Red_Blood_Cell_Acetylcholineste.pdf PDF
Attach_33_Preparation_of_QC-QA_Controls.pdf PDF
Attach_5_Visitor_Access_Policy.pdf PDF
Attach_15_Medical_Forms_and_Screening_Information.pdf PDF
Attach_4_Statement_of_Equivalent_Hires.pdf PDF
Attach_14_Government_Facilities_Layout.pdf PDF
Attach_40_CDP_IT_Security_Awareness_and_Training.pdf PDF
Attach_13_Vehicle_Management_Procedures.pdf PDF
Attach_32_Bloodborne_Pathogen_Exposure_Control.pdf PDF
Attach_24_USAPHC_Red_Blood_Cell-Cholinesterase_Testing_and_Quality_Assurance.pdf PDF
Attach_2_Quality_Assurance_Surveillance_Plan.pdf PDF
Attach_31_Sample_Collection_Processing_Shipping.pdf PDF
Attach_27_Calibration_of_Substrate_Repipet.pdf PDF
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Medical Support Services

Center for Domestic Preparedness (CDP)

Anniston, AL

Attachment 21

DECON of Patient in COBRATF Training Medical Room

FOR OFFICIAL USE ONLY

STANDARD OPERATING PROCEDURE

Organization: Center for Domestic Preparedness Date: October 17, 2012

Title: Decontamination of Patient in Training Building Medical Room

CDP-COBRATF-19.7.0

I. Purpose

To establish procedures for the decontamination of a patient(s) that has been passed into the training building medical room from the anteroom.

II. Supersession

This SOP supersedes:

CDP MSS EMS.02.0.WI, Decon of Patient in Medical Room, Effective 07/08/2011

III. Authority

COBRATF Standards Document

IV. Reference

A. CDP COBRATF SOP 1.18, Disposition of Expendable and Non-Expendable Materials in the Toxic Agent Area

B. CDP COBRATF SOP 1.21, Improved Chemical Agent Monitor (ICAM)

C. CDP COBRATF SOP 1.23, M8 Detector Paper

D. CDP COBRATF SOP 8.6, MINICAMS Air Monitoring Method

E. CDP COBRATF SOP 16.3, Emergency Response Procedures During Training

V. Definitions

A. APR – Air Purifying Respirator

B. IAW – In Accordance With

C. ICAM – Improved Chemical Agent Monitor

D. LCD – Lightweight Chemical Detector

E. MINICAMS – Miniature Continuous Air Monitoring System

F. MSS – Medical Support Services

G. PPE – Personal Protective Equipment

VI. Responsible Office

COBRATF Lead Paramedic

CDP-COBRATF-19.7.0

FOR OFFICIAL USE ONLY 2

VII. Standard Operating Procedures

A. The COBRATF Lead Paramedic or, in his/her absence, the most senior paramedic on duty, is responsible for assuring all personnel have and wear level “C” while treating patients from the toxic agent area.

B. Paramedics have been approved by the MSS contract physician to wear two (2) pair of medical examination gloves or one (1) pair of butyl rubber gloves while treating patients from the toxic agent area.

C. After the patient(s) has been delivered to the training building medical room from inside the toxic agent area, the medical room is monitored by the MINICAMS for a minimum of ten (10) minutes IAW CDP COBRATF 8.6.

D. The paramedics immediately monitor the patient with an ICAM IAW CDP COBRATF

1.21, or LCD (if available), and M8 detector paper IAW CDP COBRATF 1.23, to verify that the patient is decontaminated or clean.

E. If air monitoring technicians notify the paramedics via Safety Control that the medical room is clean and the patient is verified clean by use of an ICAM or LCD, and M8 detector paper, the paramedics may remove their PPE. The patient may then be transported, if needed, to the hospital via ambulances or air evacuation at the discretion of the Lead Paramedic and/or senior paramedic, or contract physician, if on site.

F. If air monitoring technicians notify the paramedics via Safety Control that the medical room is contaminated, perform the following procedures:

1. Retrieve modified garden hose, two (2) buckets and two (2) sponges from beneath the sink. Tighten the bracket around the hose onto the faucet adapter over the sink. Fill buckets with soap and cold water and place a sponge in each bucket.

2. While the patient is laying on the treatment/containment bed, sponge them with soap and water from head to toe, including both sides of the body, to ensure decontamination of all parts of the body. Rinse with cold water from the hose.

3. Decontamination includes the APR. Exercise caution to not get soap and water around/in the inlet valve.

4. Roll patient onto one side, preferably the side opposite the canister side of the APR, and sponge the entire posterior side of the body with soap and water. Rinse the posterior body with cold water from the hose.

5. Capture all soap and rinse water in the decontamination capture bin for disposal.

6. When the decontamination process is complete, notify safety control and request air monitoring to begin sampling the medical room again.

7. The paramedics monitor the patient with an ICAM or LCD (if available), and M8 detector paper to verify that the patient has been successfully decontaminated.

8. If the medical room or the patient is determined to be contaminated, repeat procedures

VII.F.1-7.

FOR OFFICIAL USE ONLY 3

9. If the patient and medical room are determined to be clean, the paramedics may remove their PPE, as well as the APR from the patient.

G. If the decontamination procedures are utilized in the training building medical room, perform the following procedures to remove the decontamination run-off capture bin from the medical room:

1. When Safety Control notifies the paramedics that air monitoring technicians have cleared the training building medical room, the Lead Paramedic, or most senior paramedic on site, advises Safety Control that he/she requires two (2) support team members to remain in the anteroom to receive the capture bin.

2. Once the patient has left the training building medical room, a minimum of one (1) paramedic, two (2) if required for training support, remains in PPE in the medical room, replaces the capture bin, opens the door to the anteroom and passes the capture bin to the support team staff for decontamination.

3. Once the anteroom door is closed, the paramedic(s) notifies Safety Control to have air monitoring technicians sample the training building medical room IAW CDP

COBRATF 8.6. Paramedics remain in PPE until air monitoring technicians advise that the medical room is clear.

4. After the capture bin is decontaminated, support team members place it in hot laundry for monitoring as “Non-Expendable Equipment” IAW CDP COBRATF 1.18.

5. Once considered cleared for removal from hot laundry, the capture bin is returned to the paramedics for use in the training building medical room.

VIII. Forms Prescribed

CDP COBRATF Form 4.18.LB, COBRATF Toxic Agent Training Checklist

FOR OFFICIAL USE ONLY 4

APPROVED BY:

Gary L. Milner Date

Assistant Director, COBRATF

Ronald J. Varcak Date

Contract Physician

Medical Support Services

Quality Review Date Chemical Hygiene Review Date

File details come from the government source that posted it. Updated .