Square-D-NQ-Panelboard-Catalog.pdf
PDF 939 KB Posted
- Attached to
- DMA- AC Chiller Unit
- Solicitation number
- HQ0516-24-R-0071
- Issued by
-
Defense Media Activity
About this file
This document is a product catalog for Square D NQ, NF, I-Line, and QMB panelboard products. It provides an overview of the features, applications, and specifications for these panelboard lines, which are designed for commercial, industrial, and utility applications. The NQ panelboards are rated up to 240VAC, the NF up to 600Y/347VAC, and the I-Line and QMB up to 600VAC. Key details include available configurations, enclosure types, circuit breaker options, and accessories such as surge suppression and 200% rated neutrals.
The related federal contract opportunity is for the installation of HVAC conduits, piping, wiring, and automatic transfer switches for the Defense Media Activity. The solicitation number is HQ0516-24-R-0071, and the description indicates this requirement is for work on the agency's campus. No additional details on the contract terms, pricing, or response due dates are provided in the information given.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NQ, NF, I-Line, and QMB Panelboard Products Reliable, Versatile, and Convenient Solutions
TM
Developed with extensive input from electrical contractors, Square D™ panelboards are built to last, easy to install, and are designed for optimum space and labor savings. Supported by the largest distribution, sales, and service organization in the industry, Square D panelboards are readily available to meet the needs of contractors, consultants, and end-users.
Application Commercial Industrial OEM Utility Residential
NQ • Schools/ Universities
• Public Buildings
• Restaurants
• Strip Malls
• Hotels/Motels
• Nursing Home
• Hospitals
• Factories
• Chemical Plants
• Water Treatment Plants
• Computer Power
• HVAC
• Panelboard Assemblers
• Equipment Rooms
• Municipal Water/
• Wastewater Facilities
• High-Rises
• Apartments
• Duplexes
NF • High Bay Lighting
• Shopping Malls
• Office Buildings
• Automotive
• Refineries
• Textile Mills
• Wastewater
• Treatment Plants
• Integrated Generator
• IEnclosures
• Panelboard Assemblers
• Equipment Rooms
• Power Generation Facilities
• Municipal Water/Wastewater Facilities
I-Line Combo Panelboard
• Office Builders
• Strip Malls
• Retail Stores
• Grocery Stores
• Nursing Homes
• Automotive
• Paper Mills
• Hospitals
• Factories
• Panelboard Assemblers
• HVAC
• Equipment Rooms
• Power Generation Facilities
I-Line • Office Buildings
• Strip Malls
• Retail Stores
• Grocery Stores
• Nursing Homes
• Automotive
• Paper Mills
• Hospitals
• Factories
• Panelboard Assemblers
• HVAC
• Equipment Rooms
• Power Generation Facilities
QMB • Strip Malls
• Retail Stores
• Grocery Stores
• Automotive
• Manufacturing Facilities
• Refineries
• Textiles
• Food Service Industry
• Panelboard Assemblers
• Equipment Rooms
• Power Generation Facilities
Product table
Features NQ NF Column Width I-Line Combo
Panelboard I-Line QMB
NQ NF
AC Voltage (max) 240 600Y/347 240 600Y/347 600Y/347 600 600
DC Voltage (max) 48 — — — 48 250 250
Main Device Amps (max) 600 600 225 225 1,200 1,200 800
Main Lugs Amps (max) 600 800 225 225 1,200 1,200 1,600
SCCR kAIC (max) 65 65 225 225 65 200 200
Plug-On/Bolt-On Branch Both Both Both Both Both Plug Plug
Top or Bottom Feed Yes Yes Yes Yes Yes Yes Yes
UL and cUL Service Equipment Yes Yes Yes Yes US Only Yes Yes
Enclosure Types 1, 3R, 4/4X, 5, 12 1, 3R, 4/4X 5, 12 1 1 1, 3R, 4/4X, 5, 12 1, 3R, 4/4X, 5, 12 1, 3R, 4/4X, 5, 12
Square D Panelboard Family
The NQ Lighting panelboards are designed to meet the evolving needs of customers with electrical lighting and distribution applications.
The innovative designs increase the availablity and adaptability of these panelboards by offering complete ready-to-install kits.
NQ Lighting Panelboards 240 Vac Maximum
Available Interiors 3P4W and 1P3W available
Maximum 600 A Main Breaker or Main Lug available
18, 30, 42, 54, 72, and 84 circuits
Main breaker or main lugs
10,000, 22,000, and 65,000 fully rated branches at 208Y/120 Vac
Series ratings to 200,000 A at 208Y/120 Vac
Available Enclosures
Types
Type 1 (Indoor)
Type 2 (Driphood)
Type 3R (Outdoor, Rain, and Sleet protection)
Type 4/4X (Stainless, corrosion protection)
Type 5 (Settling dust and dripping liquids protection)
Type 12 (Circulating dust and dripping liquids protection)
Trims
Surface and flush non-vented Mono-Flat™ trims for 250 A and below
Surface and flush screwed-to-box vented for 400 A and above
Hinged trim available; meets door-in-door specs
Separate trim not required for Type 3R, 4, 4X, 5, and 12 enclosures
NQ panelboards meet 240 Vac applications and accept both the QO plug-on and QOB bolt-on circuit breakers.
Available Options
Copper bussing, copper lugs, copper neutrals
Copper and aluminum, mechanical and crimp lugs
Rail and dead front extension kits providing space only for future addition of ready-to-install kits (extensions of 6”, 12”, and 18” available)
Increased side gutters 3”, 6”, and 12”
Split bus
Contactors
Equipment space
Locks (most common brands)
In-line surge suppression
Sub-feed lugs*
Sub-feed breakers*
Feed-through lugs*
200% neutrals*
* Field-installable
The NF panelboard offers superior performance and application flexibility for commercial and industrial electrical systems up to 600Y/347 Vac. This versatile lighting and power distribution panelboard features a wide selection of circuit breakers, accessories, and ready-to-install kits, as well as 200% rated neutrals for non-linear loads.
NF Lighting Panelboards 600Y/347 Vac Maximum
Available Interiors 3P4W and 1P3W available
Maximum 800 A Main Breaker or Main Lug available
18, 30, 42, 54, 66, and 84 circuits
Main breaker (600 A) or main lug (800 A)
Fully rated branches:
— 480Y/277 Vac: 18,000 A, 35,000 A, and 65,000 A
— 600Y/347 Vac: 14,000 A, 18,000 A, and 35,000 A
Series Ratings 480Y/277 Vac: 200,000 A maximum
600Y/347 Vac: 200,000 A maximum
Available Enclosures Types
Type 1 (Indoor)
Type 2 (Driphood)
Type 3R (Outdoor, rain and sleet protection)
Type 4/4X (Stainless, corrosion protection)
Type 5 (Settling dust and dripping liquids protection)
Type 12 (Circulating dust and dripping liquids protection)
Trims
Surface and flush non-vented Mono-Flat trims for 250 A and below
Surface and flush screwed-to-box vented for 400 A and above
Hinged trim available; meets door-in-door specs
Separate trim not required for Type 3R, 4, 4X, 5, and 12 enclosures
NF panelboards offer application flexibility for commercial and industrial electrical systems up to 600Y/347 Vac.
Available Options
Copper bussing, copper lugs, copper neutrals
Copper and aluminum, mechanical and crimp lugs
Rail and dead front extension kits provide space only for future addition of ready-to-install kits (extensions of 6”, 12”, and 18” available)
Increased side gutters 3”, 6”, and 12”
Split bus
Contactors
Equipment space
Locks (most common brands)
In-line surge suppression
Sub-feed lugs*
Sub-feed breakers*
Feed-through lugs*
200% neutrals*
* Field-installable
I-Line Combo Panelboards 600Y/347 Vac Maximum
The new Square D I-Line™ Combo Panelboard will change the way you install panelboards. Its simple, flexible, and innovative design uses a smaller footprint and delivers significant savings on installation time, labor expenses, and materials costs.
A wide variety of customizable assemblies are available for field or factory installation.
Available Options The I-Line Combo Duplex Panelboard, with optional mounting space, provides the capability for future site growth.
Ready-to-Install Kits
Dual 18-circuit section assembly Single 18-circuit section with contactor mounting assembly
Additional 42-circuit section assembly
Contactor mounting kit for up to three contactors
Factory Assembled Options*
Powerlink™ lighting section in 42 or 54 circuit configurations
* Options listed above for ready-to-install configurations can be ordered as cable fed factory assembled configurations.
Available Interiors:
3P4W, 3P3W, 1P3W, and 1P2W available
1,200 A main circuit breakers or 800 A main lugs
Single or Duplex configurations available
— 18” or 22.5” of I-Line mounting space; up to 54 available lighting circuits
— 22.5” or 31.5” of I-Line mounting space; up to 84 lighting circuits
— 22.5” or 31.5” of I-Line mounting space; up to 54 lighting circuits and optional mounting space for customizable assemblies
Fully rated and series rated systems available
Available Enclosures Types
Type 1 (Indoor)
Type 2 (Driphood)
Type 3R (Outdoor, Rain, and Sleet protection)
Type 4/4X (Stainless, Corrosion protection)
Type 5 (Settling dust and dripping liquids protection)
Type 12 (Circulating dust and dripping liquids protection)
Trims
Standard trims available (door not included)
Four-piece Surface or Flush construction
Optional four-piece trim with door
Accessories Plated copper or aluminum bus
6”, 9”, or 12” box extensions
14” side car enclosures
Optional 200% rated neutrals through 1,200 A
Communication capabilities available with use of PowerPact™ with Micrologic™ Trip Unit circuit breakers
I-Line Power Panelboards 600 Vac Maximum
Available Interiors:
3P4W, 3P3W, 1P3W, and 1P2W available
1,200 A main circuit breaker or main lugs
Up to 108 inches of I-Line circuit breaker mounting space
Fully rated and series rated systems available
Available Enclosures Types
Type 1 (Indoor)
Type 2 (Driphood)
Type 3R (Outdoor, Rain, and Sleet protection)
Type 4/4X (Stainless, Corrosion protection)
Type 5 (Settling dust and dripping liquids protection)
Type 12 (Circulating dust and dripping liquids protection)
Trims
Standard trims available (door not included)
Four-piece Surface or Flush construction
Optional four-piece trim with door
Available Options A wide variety of accessories are available for field or factory installation of I-Line power panelboards.
Plated copper or aluminum bus
Sub-feed or through-feed lugs through 1,200 A
6”, 9” or 12” box extensions
Split bus bar
Optional 200% rated neutrals through 1,200 A
Optional customer metering with PowerLogic™ power meters or circuit monitors
100,000 A to 240,000 A plug-on SPD modules
Six circuit QO 240 V plug-in distribution module
Ground fault protection available on main or branch circuit breakers
The I-Line power distribution panelboard is the most versatile on the market and features the Schneider Electric™ unique breaker engagement system. It is used to feed NQ and NF lighting and appliance panelboards and is capable of feeding large motor loads. Wherever electricity is distributed or controlled, you’ll find I-Line Power Panelboards.
The industry exclusive I-Line stacked bus structure was designed with the installer in mind ensuring simple and quick breaker installation.
When specifications or electrical codes call for a fusible panelboard, the QMB family offers unbeatable performance and time-saving installation features. The QMB power distribution panelboard feeds motors, transformers, and lighting systems.
QMB Power Panelboards 600 Vac Maximum
Fuse Selection Guide for Main and Branch Switches
UL
Class
Voltage Ampere Ratings
AIC Fuse Type Loads
H 600 V 1 – 600 A 10,000 A One-time Miscellaneous loads
J 600 V 1 – 600 A 200,000 A Time-delay Motors, welders, etc.
J 600 V 1 – 600 A 200,000 A Fast-acting Non-motor loads
L 600 V 601 – 800 A 200,000 A Time-delay All type loads
L 600 V 601 – 800 A 200,000 A Time-delay Non-motor loads
RK1 600 V 1 – 400 A 200,000 A Dual element time-delay All type loads
RK1 600 V 401 – 600 A 100,000 A Dual element time-delay All type loads
RK5 600 V 1 – 400 A 200,000 A Dual element time-delay
Motors, welders, transformers
RK5 600 V 401 – 600 A 100,000 A Dual element time-delay
Motors, welders, transformers
T 600 V 1 – 800 A 200,000 A Fast-acting Non-motor loads
The reliability of the QMB power panelboard makes it the product of choice for large commercial and industrial applications.
Available Interiors:
600 Vac, 250 Vdc maximum
Maximum main lugs 1,200 A
Maximum main switch 800 A
Fusible switches are rated for 200 K RMS symmetrical amperes with appropriate Class J, L, R, or T fuses installed
Branch devices include 30 A – 800 A fusible switches, 15 A – 400 A circuit breakers
Available Enclosures Types
Type 1 (Indoor)
Type 3R (Outdoor, Rain, and Sleet protection)
Trims
Four-piece, surface
File details come from the government source that posted it. Updated .