About this file

This document is a product specification cut sheet for the Vertiv Liebert CRV, a row-based cooling solution for IT equipment in small to medium data centers and edge computing locations. The Liebert CRV is available in direct expansion and chilled water versions, with cooling capacities ranging from 10 to 46 kW. Key features include cooling capacity modulation, variable speed fans, and integrated controls to optimize efficiency and reliability.

The related federal contract opportunity is for the installation of HVAC equipment, including conduits, wiring, chilled water piping, and automatic transfer switches for fire pumps, at a facility operated by the Defense Media Activity. The solicitation number is HQ0516-24-R-0071.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Vertiv™ Liebert® CRV from 10 to 46 kW

Eff icient Cooling for IT Equipment

Vertiv™ Liebert® CRV from 10 to 60 kW

Liebert CRV is a comprehensive row-based solution that includes all of the main functions fundamental to cooling units, such as cooling, humidification, dehumidification, re-heating, air filtration, condensation management, temperature and humidity control, alarm functions and data communications.

Furthermore, the unit enhances its performances and energy eff iciency through the Vertiv™ iCOM™ Control, capable of optimizing unit operations by leveraging on its intelligent management of system components. All components are easily accessible from the front and the rear of the unit, granting simplified service intervention.

The unit also allows ease of installation, through simplified cable and pipes routing from top and bottom of the unit.

Liebert® CRV Row-Based Cooling

Vertiv™

Vertiv designs, builds and services mission critical technologies that enable the vital applications for data centers, communication networks, and commercial and industrial environments. We support today's growing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented by our global service network. Bringing together global reach and local knowledge, and our decades-long heritage including brands like Chloride®, Liebert®, Geist® and NetSure™, our team of experts is ready to take on your most complex challenges, creating solutions that keep your systems running — and your business moving. Together, we’re building the future of a world where critical technologies always work.

YOUR VISION, OUR PASSION.

Vertiv.com

The Liebert CRV, row-based cooling unit is optimized to ensure maximum cooling capacity in a minimal footprint. Targeted for small and medium data centers, as well as edge computing locations the unit provides cooling at the server rack level.

The Liebert CRV has been designed to deliver the highest eff iciency and availability, by removing heated air from the data center hot aisles, using it to return cooled air to the servers (cold aisle). The Liebert CRV is available in Direct Expansion, as well as Chilled Water versions and in two frame widths - 600 mm and a compact 300 mm. Providing full capacity and airflow modulation to match the servers' load, the unit is able to deliver energy savings via its compressor with capacity modulation, Electronic Expansion Valve and variable speed EC Fans. All this leads to very low operating costs with maximum availability. The

Vertiv™ Liebert® CRV 600mmVertiv™Vertiv™Vertiv Liebert® CRV 600mm

Designed to Optimize IT Performance

The Vertiv™ Liebert® CRV in-row cooling unit is ideal for the cooling of data center rows.

The Liebert CRV is a multi-option, precision air conditioner that delivers temperature and humidity control, as well as filtration and notification management, ensuring that data center temperatures are maintained at an optimum level.

The unit is designed to continuously monitor variations in heat loads and instantly deliver the most eff icient and eff ective cooling necessary.

Liebert CRV: Simple, Safe, Adaptable

The Liebert CRV is a plug-and-play unit with the capability of addressing the needs of both open and contained applications.

Cooling is provided at the server rack level rather than the room level. The Liebert CRV removes and filters hot air from the data center aisles, using it to return cooled air to the servers.

The integrated air diff users accurately direct the airflow towards the necessary direction of the heat load.

Furthermore, Liebert CRV is designed to comply with mission-critical requirements and ensure that servers are maintained at the correct temperature and humidity levels.

For low operational costs, the Liebert CRV provides the exact level of cooling required by servers, modulating the airflow and cooling capacity.

The unit is available in two versions to meet various installation demands:

y A stand-alone, direct expansion system with variable capacity up to 36 kW, available in both 300 mm and 600 mm versions, complete with roof or wall-mounted condenser y A chilled water system with up to 46 kW of capacity available in both 300 mm and 600 mm versions y Units ranging from 10 to 46 kW with chilled water and direct expansion versions y Industry's highest energy saving levels achieved -increase of up to 50% when the Liebert CRV is combined with Vertiv™ SmartAisle™ cold aisle containment y Best-in-class Thermal Management unit for row-based applications y On-site adjustment capability of air diff user distribution direction maximizes cooling results y Integrated Vertiv ICOM™ Control for management of capacity and airflow through EC Fans and variable capacity Compressor y Ideal for scalable IT infrastructure - increased cooling capacity, reduced noise levels and enhanced eff iciency when compared with similar chilled water and direct expansion configurations.

Features and Performance

The integrated compressors with cooling capacity modulation are designed to avoid peaks in absorbed power, thus reducing the stress placed on components. The Liebert CRV uses a dedicated control that also enables the compressor to operate when the external air temperature increases above standard limits.

Meeting Primary IT Requirements

The Liebert CRV's ability to modulate capacity allows for constant, accurate room temperature and humidity levels to be maintained.

The variable capacity capability of the Liebert CRV, contributes to increasing data center availability during both standard operations and in the event of load variations.

A reduction in its start/stop cycling function further contributes to increasing data center availability, as well as lengthening the life of critical components.

Extreme Flexibility for Open and Closed Architectures

Suitable For a Wide Range of Installations

The Liebert CRV addresses the cooling needs of both new and existing data center space, regardless of raised floor availability. It is ideally suited to data centers with up to 50 racks, irrespective of heat load.

Configuration Flexibility

The Liebert CRV can be configured to perform temperature as well as humidity control.

The Liebert CRV 300 mm and 600 mm width versions have been designed to specifically meet the requirements of data centers in need of optimizing space occupancy, as well as capital and running costs.

The Ideal Airflow

EC Fans and compressors with variable cooling capacity, managed through integrated Vertiv ICOM Control, achieve flexible capacity and airflow for the ideal operating conditions of IT equipment.

The Liebert CRV, designed using advanced, computer-aided dynamic fluid technology, delivers optimum air distribution across rack installations. The exceptional levels of air distribution have been proven as a result of wide-scale laboratory and field testing

Ensuring Availability Under All Working Conditions

Maintaining IT Infrastructure Availability

With integrated Vertiv™ ICOM™ Control, the Liebert® CRV is able to monitor variations in temperature and humidity, instantly adapting its performance to meet variations in load conditions.

This furthermore ensures increased availability and safety of protected IT equipment.

The Liebert CRV's constant temperature monitoring and control capabilities ensure the availability of servers in all working conditions.

Furthermore, its parallel load sharing functionality enables the management of N+1 configurations.

Customer Monitoring Interfaces

Monitoring and Control Through Existing Network Via your Web Browser

The Liebert® CRV system can be fitted with a Vertiv monitoring card allowing full advantage to be taken of the Ethernet network and remote monitoring from your computer desktop, network operations center or any network access simply utilizing a standard web browser. A standard web browser, via HTTP protocol or Network Management System software via SNMP protocol, can be used to access the unit information.

Monitoring Integration with Existing Building Management System

If required, by installing the optional monitoring card, the Liebert CRV can be monitored and controlled by an existing Building Management System.

The monitoring card provides Modbus, Bacnet and SNMP protocol support.

Liebert® CRV Technical Data

Direct Expansion Water/Glycol Chilled Water

Model CRD10 CR019 CR020 CR035 CR019 CR020 CR035 CR032 CR040

Net Sensible Cooling Capacity (kW) 10 20 23 36 21 23 37 27 46

Nominal Airflow (CFM) 1883 2610 2216 1615 2610 2216 1615 2500 3620

Unit Weight (lb) 509 507 739 805 545 772 849 418 728

Unit Width (mm) 300 300 600 600 300 600 600 300 600

Unit Depth (mm) 1132 1100 1100 1100 1100 1100 1100 1100 1100 Unit Height (mm) 2000 2000 2000 2000 2000 2000 2000 2000 2000

Note: Cooling Capacity tested at an air inlet temperature of 95°F, outdoor temperature for DX and W/G units of 95°F, and CW temperature delta of 10°F. For more information, please reference the CRV Data Sheet. CRD10 performance tested at Return air 29.4°C (85°F), 32% RH & 35°C (95°F) Outdoor temperature.

STANDARD FEATURES AND OPTIONS

DX Version CW Version y High Efficiency Scroll/Rotary Compressor with Capacity Modulation (CRD10 utilizes an Inverter Driven Compressor)

y EC plug fans
y R410A Refrigerant
y Adjustable modular baffle system
y Top/Bottom connections
y Levelling feet
y Filters with up to MERV 11 filtration

class and clog filter switch

y Electrode humidifier (600mm only)
y Electric reheat 1-stage (600mm only)
y Internal condensate pump
y User friendly touchscreen display
y Remote rack temperature sensors
y Monitoring card for WEB, Modbus and

BACnet y Teamworking functionality

y EC plug fans
y 3-way or 2-way valve with

0-10V actuator

y Adjustable modular baffle system
y Top / Bottom connections
y Levelling feet
y Filters with up to MERV 11

filtration class and clog filter switch y Electrode humidifier (600mm only) y Electric reheat 1-stage (600mm only)

y Internal condensate pump
y User friendly touchscreen display
y Remote rack temperature sensors
y Monitoring card for WEB,

Modbus and BACnet y Teamworking functionality

Liebert® CRV 300 mm DX

ADDITIONAL OPTIONS

DX Version CW Version

y Additional remote rack temperature sensors
y Compressor jacket (600mm models)
y Dual power supply with ATS on selected

models y Optional extension frame for height 2200 mm and depth 1200mm (CRD10 only)

y Reheat and humidifier lockout (600mm only)
y Seismic rating

y Additional remote rack temperature sensors y Reheat and humidifier lockout (600mm only) y Seismic rating

D

H

W

Coupling Air Cooled Liebert CRV Units with Air Cooled Condensers

Chilled water cooling units may be coupled with Vertiv™ chillers (Liebert HPC or Liebert AFC series). The Liebert HPC chiller series off ers a wide range of air cooled or water cooled solutions. Available with various noise thresholds and with freecooling modes, these units significantly enhance the system's energy saving capabilities. Liebert HPC freecooling chillers are available from 40 kW to 1600 kW. The Liebert AFC, Adiabatic Freecooling Chillers, are available from 500 kW to 1700 kW and are designed to maximize data center eff iciency and availability.

Chilled Water Cooling

Condensers Dimensions

Width Depth Height Weight

CCD100S-00A [mm] / [lb] 745 450 1300 123

MCS028E1 [mm] / [lb] 1080 1287 1006 154

MCM040E1 [mm] / [lb] 1168 1453 1006 231

MCL055E1 [mm] / [lb] 1410 1727 1006 344

MCM080E1 [mm] / [lb] 1168 2674 1006 441

Model

Outdoor Temperature up to 95°F up to 40°C up to 45°C

CRD10 up to 105°F CCD100S-00A CCD100S-00A

CR019RA up to 115°F MCM040E1 MCL055E1

CR020RA MCS028E1 MCM040E1 MCL055E1

CR035RA MCM040E1 MCL055E1 MCM080E1

Model Ambient Temperature up to 95°F Ambient Temperature up to 100°F Ambient Temperature up to 105°F

CR019RW DSF112_8 DSO174_8 DSO225_16

CR020RW DSF112_8 DSO174_8 DSO225_16

CR035RW DSO197 DSO310_16 DSO419_16

Coupling Water/Glycol Cooled Liebert CRV Units with Drycoolers

Width Depth Height Weight

DSF112_8 [mm] / [lb] 1107 1308 1095 435

DSO174_8 [mm] / [lb] 1107 2324 1095 540

DSO225_16 [mm] / [lb] 1107 2324 1095 620

DSO197 [mm] / [lb] 1107 2324 1095 580

DSO310_16 [mm] / [lb] 1107 3340 1095 795

DSO419_16 [mm] / [lb] 1107 4356 1095 1020

Dry Cooler Dimensions

Fully integrate your IT deployments with Vertiv™ solutions

Vertiv off ers an industry-leading portfolio of physical infrastructure, services, and monitoring software.

Vertiv™ VR Racks

Supports a wide variety of equipment and gives you the flexibility you need with easy installation.

Vertiv™ Aisle Containment

Maximize your eff iciency and capacity from the core to the edge with adaptable hot or cold aisle containment.

Vertiv™ Geist™ rPDU

Reliably distributes power to the rack, supporting dynamic data center operations and DCIM.

Vertiv™ Liebert® CRV

Delivers highly eff icient and scalable in-row cooling to maintain optimal thermal operating conditions for maximum system reliability.

Vertiv™ Liebert® GXT5

Helps protect mission critical equipment from all power disturbances due to blackouts, brownouts, sags, surges or noise interference

Vertiv™ Services

Protect your critical IT system with a host of Vertiv services for all products listed above.

When your business relies on high system performance and availability, having Vertiv certified technicians on hand to provide their expertise should be your top priority.

Services available from global leaders in data center infrastructure services.

Nobody keeps more data centers up and running than Vertiv.

Want to Learn More?

Contact us: AskTheExpert@Vertiv.com

Services available from global leaders in Services available from global leaders in running than Vertiv.

Learn more about Edge Solutions at Vertiv.com

Racks & Containment

IT Management

Power Distribution

Thermal Management

UPS Battery Backup

Lifecycle Services

Vertiv.com | Vertiv Headquarters, 505 Cleveland Ave., Westerville, OH, 43082, USA

© 2023 Vertiv Group Corp. All rights reserved. Vertiv™ and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness here, Vertiv Group Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications, rebates and other promotional off ers are subject to change at Vertiv’s sole discretion upon notice.

SL-11999 (R09/23)