| Summation of RPIE for McGuire AFB | ||||
| 02417 - DENTAL CLINIC | ||||
| Facility System | Facility Subsystem | Assembly Category | Nomenclature | RPIE Count |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | BELL | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | FIRE ALARM CONTROL PANEL | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | FLASHING LIGHT VISUAL ALARM | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | SMOKE DETECTOR | 1 |
| ELECTRICAL POWER & DISTRIBUTION | PRIMARY POWER | MAIN TRANSFORMER | POWER TRANSFORMER (OIL FILLED) | 1 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | ENCLOSED CIRCUIT BREAKER | MOTOR STARTER DISCONNECT | 2 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | INTERIOR DISTRIBUTION TRANSFORMER | TRANSFORMER (DRY TYPE) | 4 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | MOTOR CONTROL CENTER | MOTOR CONTROL CENTER | 2 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | MOTOR CONTROL CENTER | MOTOR STARTER | 1 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | 16 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | 8 |
| ELECTRICAL POWER & DISTRIBUTION | SPECIAL SYSTEM | LOW VOLTAGE CONTROL UNIT | AUTOTIMER | 1 |
| ELECTRICAL POWER & DISTRIBUTION | SPECIAL SYSTEM | LOW VOLTAGE CONTROL UNIT | RECTIFIER | 1 |
| FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | 9 |
| FIRE PROTECTION SYSTEM | STANDPIPE SYSTEMS | <NA> | STANDPIPE EQUIPMENT & PIPING | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | CONTROLS & INSTRUMENTATION | HVAC CONTROL | ELECTRICAL CONTROL PANEL | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CHILLED WATER SYSTEM | RECIPRICAL CHILLER COMPRESSOR | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CHILLED WATER SYSTEM | RECIPROCAL CHILLER | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION, COOLING & HEATING | AIR HANDLING UNIT MOTOR | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | AIR HANDLING UNIT | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | AIR HANDLING UNIT MOTOR | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | RETURN FAN | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | RETURN FAN MOTOR | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP MOTOR | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | 6 |
| HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | 6 |
| HEATING, VENTILATION & AIR CONDITIONING | HEAT GENERATING SYSTEM | STEAM BOILER | HEATING WATER RECIRCULATING PUMP | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER | 1 |
| PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL AIR | 1 |
| PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL AIR COMPRESSOR | 2 |
| PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL AIR DRYER | 1 |
| PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL AIR MOTOR | 2 |
| PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL VACUUM PUMP SET | 2 |
| PLUMBING | DOMESTIC WATER SUPPLY | ELECTRIC HEATING ELEMENT | DOMESTIC WATER HEATER | 1 |
| PLUMBING | DOMESTIC WATER SUPPLY | <NA> | BACKFLOW PREVENTER | 2 |
| PLUMBING | DOMESTIC WATER SUPPLY | <NA> | DOMESTIC HOT WATER PUMP | 1 |
| PLUMBING | MEDICAL GAS SYSTEM | <NA> | VACUUM PUMP MOTOR | 4 |
| PLUMBING | PLUMBING FIXTURES | <NA> | DRINKING FOUNTAIN | 2 |
| PLUMBING | PROCESS AIR SYSTEM | <NA> | INSTRUMENT AIR DRYER | 1 |
| PLUMBING | PROCESS AIR SYSTEM | <NA> | PNEUMATIC AIR COMPRESSOR | 2 |
| PLUMBING | SANITARY WASTE & VENT SYSTEM | <NA> | SUMP PUMP | 2 |
| Sum: | 103 | |||
| 03457 - BIO ENVIRONMENTAL/PUBLIC HEALTH | ||||
| Facility System | Facility Subsystem | Assembly Category | Nomenclature | RPIE Count |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | AUDIO VISUAL ALARM | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | DUCT SMOKE DETECTOR | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | FLOW SWITCH | 2 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | HEAT DETECTOR | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | MAIN ANNUNCIATOR PANEL | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | PULL STATION | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | TAMPER SWITCH | 2 |
| ELECTRICAL POWER & DISTRIBUTION | PRIMARY POWER | MAIN SWITCHBOARD | MAIN DISTRIBUTION PANEL | 1 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | ENCLOSED CIRCUIT BREAKER | MOTOR STARTER DISCONNECT | 5 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | 1 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | VARIABLE FREQUENCY DRIVE | 1 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | 4 |
| ELECTRICAL SYSTEM | LIGHTNING PROTECTION SYSTEM | <NA> | LIGHTNING PROTECTION | 1 |
| EMERGENCY POWER & LIGHTING | EMERGENCY LIGHTING | EGRESS LIGHTING | EXIT LIGHT | 1 |
| EXTERIOR CLOSURE | EXTERIOR WALL | EXTERIOR LOUVER AND SCREEN | BUILDING EXTERIOR | 1 |
| FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | 2 |
| FIRE PROTECTION SYSTEM | SPRINKLERS | <NA> | FIRE ALARM SYSTEM | 1 |
| FIRE PROTECTION SYSTEM | SPRINKLERS | <NA> | SPRINKLER SYSTEM | 1 |
| FIRE PROTECTION SYSTEM | STANDPIPE SYSTEMS | <NA> | FIRE DEPARTMENT CONNECTION | 2 |
| FIRE PROTECTION SYSTEM | STANDPIPE SYSTEMS | <NA> | STANDPIPE EQUIPMENT & PIPING | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CHILLED WATER SYSTEM | RECIPROCAL CHILLER | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION, COOLING & HEATING | AIR HANDLING UNIT MOTOR | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | AIR HANDLING UNIT | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | SUPPLY FAN | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | SUPPLY FAN MOTOR | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP MOTOR | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CIRCULATING PUMP | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CIRCULATING PUMP MOTOR | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | HOT WATER DISTRIBUTION SYSTEM | HOT WATER PUMP | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | HOT WATER DISTRIBUTION SYSTEM | HOT WATER PUMP MOTOR | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | ENERGY SUPPLY | HOT WATER SUPPLY SYSTEM | EXPANSION TANK | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | HEAT GENERATING SYSTEM | HOT WATER BOILER (SPACE HEATING) | BOILER HOT WATER | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER | 4 |
| HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER MOTOR | 4 |
| PLUMBING | DOMESTIC WATER SUPPLY | <NA> | BACKFLOW PREVENTER | 2 |
| PLUMBING | DOMESTIC WATER SUPPLY | OIL OR GAS FIRED | DOMESTIC WATER HEATER | 1 |
| PLUMBING | PLUMBING FIXTURES | <NA> | DRINKING FOUNTAIN | 1 |
| ROOFING | ROOF COVERING | <NA> | MANUFACTURED ROOFING | 1 |
| Sum: | 64 | |||
| 03458 - MEDICAL CLINIC | ||||
| Facility System | Facility Subsystem | Assembly Category | Nomenclature | RPIE Count |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | AUDIO VISUAL ALARM | 2 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | DUCT SMOKE DETECTOR | 43 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | FIRE ALARM CONTROL PANEL | 2 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | FLASHING LIGHT VISUAL ALARM | 2 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | FLOW SWITCH | 4 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | HEAT DETECTOR | 8 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | MAIN ANNUNCIATOR PANEL | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | MANUAL PULL STATIONS 1-37 | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | REMOTE ANNUNCIATOR | 6 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | SMOKE DETECTOR | 8 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | TAMPER SWITCH | 2 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | WATER FLOW SWITCH | 1 |
| ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | SMOKE CONTROL SYSTEMS - ACTIVE | BEAM SMOKE DETECTORS | 1 |
| COMMUNICATIONS SYSTEM | NURSE CALL SYSTEM | <NA> | NURSE CALL | 1 |
| CONVEYING SYSTEM | PASSENGER ELEVATOR | HYDRAULIC LIFT MECHANISM | ELEVATOR | 1 |
| CONVEYING SYSTEM | PASSENGER ELEVATOR | HYDRAULIC LIFT MECHANISM | ELEVATOR MOTOR | 1 |
| CONVEYING SYSTEM | SERVICE ELEVATOR | ELECTRICAL LIFT MECHANISM | ELEVATOR CONTROLLER | 2 |
| CONVEYING SYSTEM | SERVICE ELEVATOR | HYDRAULIC LIFT MECHANISM | ELEVATOR | 1 |
| CONVEYING SYSTEM | SERVICE ELEVATOR | HYDRAULIC LIFT MECHANISM | ELEVATOR MOTOR | 1 |
| ELECTRICAL POWER & DISTRIBUTION | PRIMARY POWER | MAIN SWITCHBOARD | MAIN DISTRIBUTION PANEL | 2 |
| ELECTRICAL POWER & DISTRIBUTION | RECEPTACLE | <NA> | RECEPTACLES | 79 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | ENCLOSED CIRCUIT BREAKER | MOTOR STARTER DISCONNECT | 27 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | INTERIOR DISTRIBUTION TRANSFORMER | TRANSFORMER (DRY TYPE) | 10 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | MOTOR CONTROL CENTER | MOTOR CONTROL CENTER | 1 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | 45 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | SWITCHGEAR | 1 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | VARIABLE FREQUENCY DRIVE | 24 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | CIRCUIT BREAKER | 21 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | DISTRIBUTION PANEL | 6 |
| ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | 40 |
| ELECTRICAL POWER & DISTRIBUTION | SPECIAL SYSTEM | LOW VOLTAGE CONTROL UNIT | AUTOTIMER | 3 |
| ELECTRICAL SYSTEM | LIGHTNING PROTECTION SYSTEM | <NA> | LIGHTNING PROTECTION | 1 |
| EMERGENCY POWER & LIGHTING | EMERGENCY LIGHTING | EGRESS LIGHTING | EXIT LIGHT | 1 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | AUTOMATIC TRANSFER SWITCH (ATS) | 7 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | BATTERY CHARGER | 2 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | CIRCUIT BREAKER | 6 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | EMERGENCY GENERATOR | 1 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | EMERGENCY GENERATOR MOTOR | 1 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | EMERGENCY POWER DISTRIBUTION PANELBOARD | 1 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | EMERGENCY POWER SUBPANEL | 31 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | FUEL OIL STORAGE TANK | 1 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | GENERATOR ALARM PANEL | 1 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | MOTOR STARTER DISCONNECT | 1 |
| EMERGENCY POWER & LIGHTING | EMERGENCY POWER | <NA> | TRANSFORMER (DRY TYPE) | 8 |
| EXTERIOR CLOSURE | EXTERIOR SPECIALTY DOORS | <NA> | AUTOMATIC DOOR | 3 |
| EXTERIOR CLOSURE | EXTERIOR SPECIALTY DOORS | <NA> | OVERHEAD & ROLL-UP DOOR | 3 |
| EXTERIOR CLOSURE | EXTERIOR WALL | EXTERIOR LOUVER AND SCREEN | BUILDING EXTERIOR | 1 |
| EXTERIOR CLOSURE | EXTERIOR WALL | EXTERIOR LOUVER AND SCREEN | LOUVERS | 1 |
| FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | 36 |
| FIRE PROTECTION SYSTEM | SPRINKLERS | <NA> | FIRE ALARM SYSTEM | 1 |
| FIRE PROTECTION SYSTEM | SPRINKLERS | <NA> | SPRINKLER SYSTEM | 1 |
| FIRE PROTECTION SYSTEM | STANDPIPE SYSTEMS | <NA> | FIRE DEPARTMENT CONNECTION | 3 |
| FIRE PROTECTION SYSTEM | STANDPIPE SYSTEMS | <NA> | STANDPIPE EQUIPMENT & PIPING | 1 |
| FIRE PROTECTION SYSTEM | WATER SUPPLY (FIRE PROTECTION) | WATER SUPPLY EQUIPMENT & PIPING | FIRE PUMP | 1 |
| FIRE PROTECTION SYSTEM | WATER SUPPLY (FIRE PROTECTION) | WATER SUPPLY EQUIPMENT & PIPING | FIRE PUMP MOTOR | 1 |
| FIRE PROTECTION SYSTEM | WATER SUPPLY (FIRE PROTECTION) | WATER SUPPLY EQUIPMENT & PIPING | JOCKEY PUMP | 1 |
| FIRE PROTECTION SYSTEM | WATER SUPPLY (FIRE PROTECTION) | WATER SUPPLY EQUIPMENT & PIPING | JOCKEY PUMP MOTOR | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | CONTROLS & INSTRUMENTATION | HVAC CONTROL | DUCT HUMIDIFIERS | 14 |
| HEATING, VENTILATION & AIR CONDITIONING | CONTROLS & INSTRUMENTATION | HVAC CONTROL | HARMONIC GUARD | 13 |
| HEATING, VENTILATION & AIR CONDITIONING | CONTROLS & INSTRUMENTATION | HVAC CONTROL | HVAC FIRE DAMPERS | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CHILLED WATER SYSTEM | SCREW-TYPE CHILLER | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CONDENSER WATER SYSTEM | CHEMICAL FEED SYSTEM | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CONDENSER WATER SYSTEM | CONDENSER WATER PUMP | 5 |
| HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CONDENSER WATER SYSTEM | CONDENSER WATER PUMP MOTOR | 5 |
| HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CONDENSER WATER SYSTEM | COOLING TOWER | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CONDENSER WATER SYSTEM | COOLING TOWER MOTOR | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION, COOLING & HEATING | AIR CURTAIN | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION, COOLING & HEATING | AIR HANDLING UNIT MOTOR | 14 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION, COOLING & HEATING | BOILER WATER PUMP P-7 | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION, COOLING & HEATING | BOILER WATER PUMP, P-8 | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | AIR HANDLING UNIT | 14 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | AIR HANDLING UNIT MOTOR | 13 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | COMPUTER RM AIR HANDLING UNIT | 13 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | MOTOR | 14 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | RETURN FAN | 14 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | SUPPLY FAN | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP | 3 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP MOTOR | 3 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | DOMESTIC HW CIRCULATING PUMP | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | HOT WATER DISTRIBUTION SYSTEM | HOT WATER PUMP | 4 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | HOT WATER DISTRIBUTION SYSTEM | HOT WATER PUMP MOTOR | 4 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | HOT WATER DISTRIBUTION SYSTEM | RECIRCULATING PUMP HEATING | 16 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | HOT WATER DISTRIBUTION SYSTEM | RECIRCULATING PUMP HEATING MOTOR | 4 |
| HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | <NA> | VAV BOX | 269 |
| HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | 30 |
| HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | 32 |
| HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | SMOKE EXHAUST FAN | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | HEAT GENERATING SYSTEM | HOT WATER BOILER (SPACE HEATING) | BOILER HOT WATER | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | HEAT GENERATING SYSTEM | OTHER HEAT GENERATING SYSTEMS | BOILER, DOMESTIC HW | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | CONDENSING UNIT | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | CONDENSING UNIT MOTOR | 6 |
| HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | DRY COOLER | 1 |
| HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | FAN COIL UNIT | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | FAN COIL UNIT MOTOR | 2 |
| HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER | 17 |
| HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER MOTOR | 11 |
| INTERIOR CONSTRUCTION | INTERIOR PERSONNEL DOOR | <NA> | FIRE DOOR | 2 |
| INTERIOR CONSTRUCTION | INTERIOR PERSONNEL DOOR | <NA> | FIRE SHUTTER | 7 |
| INTERIOR CONSTRUCTION | INTERIOR SPECIALTY DOORS | <NA> | AUTOMATIC DOOR | 4 |
| PLUMBING | DOMESTIC WATER SUPPLY | ELECTRIC HEATING ELEMENT | DOMESTIC WATER HEATER | 3 |
| PLUMBING | DOMESTIC WATER SUPPLY | <NA> | BACKFLOW PREVENTER | 2 |
| PLUMBING | DOMESTIC WATER SUPPLY | <NA> | STORAGE TANK | 1 |
| PLUMBING | MEDICAL GAS SYSTEM | MEDICAL GAS & VACUUM ALARM SYSTEM | ALARM PANEL | 5 |
| PLUMBING | MEDICAL GAS SYSTEM | MEDICAL GAS & VACUUM PIPING SYSTEM | ZONE VALVE BOX | 5 |
| PLUMBING | PLUMBING EQUIPMENT | DOMESTIC WATER SUPPLY EQUIPMENT | FLOOR DRAIN | 7 |
| PLUMBING | PLUMBING FIXTURES | <NA> | DRINKING FOUNTAIN | 11 |
| PLUMBING | PROCESS AIR SYSTEM | <NA> | AIR COMPRESSOR | 3 |
| PLUMBING | PROCESS AIR SYSTEM | <NA> | AIR COMPRESSOR MOTOR | 3 |
| PLUMBING | SPECIAL PLUMBING SYSTEM | <NA> | LAWN SPRINKLER | 1 |
| ROADS & GROUNDS | LANDSCAPING | IRRIGATION SYSTEM | LAWN AERATE | 1 |
| ROOFING | ROOF COVERING | <NA> | MANUFACTURED ROOFING | 1 |
| SPECIAL CONSTRUCTION EQUIPMENT | WASH RACK | OTHER SPECIAL CONSTRUCTION | DOCK LEVELER | 2 |
| SPECIAL CONSTRUCTION EQUIPMENT | WASH RACK | OTHER SPECIAL CONSTRUCTION | DOCK LEVELER MOTOR | 2 |
| Sum: | 1069 |
ACTIVE RPIE-Full Details
| RPIE INVENTORY REPORT | |||||||||||||||
| MCGUIRE AFB | |||||||||||||||
| 02417 - DENTAL CLINIC | |||||||||||||||
| RPIE ID | Facility System(RPIE Details) | Facility Subsystem(RPIE Details) | Assembly Category(RPIE Details) | Nomenclature(RPIE Details) | Manufacturer Name | Model Number | Manufacturer Serial Number | Room # | Other Location | Risk Factor | Installation Date | Life Expectancy | Capacity Unit | Capacity Value | Spec Data (All in Single Cell) |
| 2417-BE01-15 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | BELL | UNKNOWN | UNKNOWN | UNKNOWN | THROUGHOUT BUILDING | CRITICAL | 01 Jan 1988 | 20.00 | ||||
| 2417-FACP-01 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | FIRE ALARM CONTROL PANEL | UNKNOWN | UNKNOWN | UNKNOWN | 140 | CRITICAL | 01 Jan 2009 | 20.00 | ||||
| 2417-SD01-04 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | SMOKE DETECTOR | UNKNOWN | UNKNOWN | UNKNOWN | THROUGHOUT BUILDING | CRITICAL | 01 Jan 1988 | 20.00 | ||||
| 2417-VA01-03 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | FLASHING LIGHT VISUAL ALARM | UNKNOWN | UNKNOWN | UNKNOWN | 103 | CRITICAL | 01 Jan 1988 | 20.00 | ||||
| 2417-ATMR-01 | ELECTRICAL POWER & DISTRIBUTION | SPECIAL SYSTEM | LOW VOLTAGE CONTROL UNIT | AUTOTIMER | INTERMATIC | T1871BR | N/A | 103 | NON-CRITICAL | 01 Jan 1988 | 20.00 | HP | 1 | AMPS - 40 | |
| 2417-DS01 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 103A | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 400; OTHER - FUSES:GOULD; PHASE - 3; VOLTS - 240 | |||
| 2417-DS02 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 103A | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 100; OTHER - FUSES:GOULD; PHASE - 3; VOLTS - 240 | |||
| 2417-DS03 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 103 | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 200; VOLTS - 600 | |||
| 2417-DS04 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 103 | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 30; VOLTS - 600 | |||
| 2417-DS05 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 103 | MECH RM / LOWER | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 30; PHASE - 3; VOLTS - 240 | ||
| 2417-DS06 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 103 | MECH RM / UPPER | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 30; VOLTS - 600 | ||
| 2417-DS07 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 103 | MECH RM / UPPER | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 30; PHASE - 3; VOLTS - 600 | ||
| 2417-DS08 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 103 | MECH RM / UPPER | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 30; PHASE - 3; VOLTS - 600 | ||
| 2417-DS09 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 142 | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 30; PHASE - 3; VOLTS - 240 | |||
| 2417-DS10 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 142 | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 30; PHASE - 3; VOLTS - 240 | |||
| 2417-DS11 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 144 | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 30; VOLTS - 240 | |||
| 2417-DS12 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | WESTING HOUSE | UNKNOWN | UNKNOWN | 144 | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 30; PHASE - 3; VOLTS - 240 | |||
| 2417-DS13 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | CUTLER-HAMMER | UNKNOWN | UNKNOWN | 115 | NON-CRITICAL | 01 Jun 1979 | 20.00 | ||||
| 2417-DS14 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 115 | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 60; PHASE - 3; VOLTS - 240 | |||
| 2417-DS15 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | UNKNOWN | UNKNOWN | 118 | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 30; PHASE - 3; VOLTS - 240 | |||
| 2417-DS16 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SQUARE D | UNKNOWN | UNKNOWN | 118 | NON-CRITICAL | 01 Jun 1979 | 20.00 | AMPS - 60; PHASE - 3; VOLTS - 240 | |||
| 2417-MCC01 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | MOTOR CONTROL CENTER | MOTOR CONTROL CENTER | SIEMENS | 9-001-53581-01 | 09-1466-53581-01 | 103 | NON-CRITICAL | 01 Jan 2008 | 20.00 | AMPS - 400; HERTZ - 60; OTHER - 25 KA; PHASE - 3; VOLTS - 460 | |||
| 2417-MCC02 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | MOTOR CONTROL CENTER | MOTOR CONTROL CENTER | SIEMENS | TYPE: FCI | SO# 1898049 | 103A | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 800; VOLTS - 480Y/277 | |||
| 2417-MS01 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | MOTOR CONTROL CENTER | MOTOR STARTER | SQUARE D | UNKNOWN | UNKNOWN | 103A | NON-CRITICAL | 01 Jan 1988 | 20.00 | ||||
| 2417-MSD01 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | ENCLOSED CIRCUIT BREAKER | MOTOR STARTER DISCONNECT | WESTING HOUSE | B-2003 | N/A | 103 | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 15; VOLTS - 480 | |||
| 2417-MSD02 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | ENCLOSED CIRCUIT BREAKER | MOTOR STARTER DISCONNECT | SIEMENS | 56272800 | N/A | 103 | NON-CRITICAL | 01 Jan 1988 | 20.00 | HERTZ - 60; PHASE - 3; VOLTS - 460 | |||
| 2417-PL140 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SIEMENS | UNKNOWN | UNKNOWN | 140 | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 90 | |||
| 2417-PL-LH1 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SIEMENS | UNKNOWN | 79-24375-GO1 | 103 | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 100; VOLTS - 480/277 | |||
| 2417-PL-LL1-1 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SIEMENS | UNKNOWN | UNKNOWN | 140 | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 225; PHASE - 3; VOLTS - 208Y/120 | |||
| 2417-PL-LL1-2 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SIEMENS | UNKNOWN | UNKNOWN | 140 | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 225; PHASE - 3; VOLTS - 208Y/120 | |||
| 2417-PL-LL2-1 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SIEMENS | UNKNOWN | 79-24375-A01 | 103 | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 225; VOLTS - 208/120 | |||
| 2417-PL-LL2-2 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SIEMENS | UNKNOWN | 79-24375-RP1 | 103 | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 225; VOLTS - 208/120 | |||
| 2417-PL-PP1 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SIEMENS | UNKNOWN | 79-24375-H01 | 103 | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 150; VOLTS - 120 | |||
| 2417-PL-PPX | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SIEMENS | UNKNOWN | UNKNOWN | 140 | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 100; PHASE - 3; VOLTS - 208Y/120 | |||
| 2417-PT01 | ELECTRICAL POWER & DISTRIBUTION | PRIMARY POWER | MAIN TRANSFORMER | POWER TRANSFORMER (OIL FILLED) | UNKNOWN | UNKNOWN | UNKNOWN | 103B | NON-CRITICAL | 01 Jan 1988 | 20.00 | ||||
| 2417-RR01 | ELECTRICAL POWER & DISTRIBUTION | SPECIAL SYSTEM | LOW VOLTAGE CONTROL UNIT | RECTIFIER | UNIVERSAL RECTIFIERS | AAP | 871115 | 103 | NON-CRITICAL | 01 Jan 1988 | 20.00 | AMPS - 9; VOLTS - 112 | |||
| 2417-T01 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | INTERIOR DISTRIBUTION TRANSFORMER | TRANSFORMER (DRY TYPE) | CHALLENGER | NONE | J91 B0914 | 103A | NON-CRITICAL | 01 Jan 1988 | 20.00 | HERTZ - 60; VOLTS - 480/208-120; KVA - 112.5; PHASE - 3 | |||
| 2417-T02 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | INTERIOR DISTRIBUTION TRANSFORMER | TRANSFORMER (DRY TYPE) | SIEMENS | NONE | K19504F | 103A | NON-CRITICAL | 01 Jan 1988 | 20.00 | HERTZ - 60; VOLTS - 480/208-120; KVA - 112.5; PHASE - 3 | |||
| 2417-T03 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | INTERIOR DISTRIBUTION TRANSFORMER | TRANSFORMER (DRY TYPE) | CHALLENGER | NONE | J91 C0108 | 103A | NON-CRITICAL | 01 Jan 1988 | 20.00 | HERTZ - 60; VOLTS - 480/208-120; KVA - 30; PHASE - 3 | |||
| 2417-T04 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | INTERIOR DISTRIBUTION TRANSFORMER | TRANSFORMER (DRY TYPE) | I T E | NONE | NONE | 103 | NON-CRITICAL | 01 Jan 1988 | 20.00 | HERTZ - 60; KVA - 45; PHASE - 3; VOLTS - 480 | |||
| 2417-FE01 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | AMEREX | B441 | SN10737 | 103 | CRITICAL | 01 Jan 1988 | 100.00 | EA | 500 LB | PSI - 250 | |
| 2417-FE02 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | AMEREX | B441 | SN107373 | C141A | CRITICAL | 01 Jan 1988 | 100.00 | EA | 500 LB | PSI - 250 | |
| 2417-FE03 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | AMEREX | B441 | SN107373 | C153A | CRITICAL | 01 Jan 1988 | 100.00 | EA | 500 LB | PSI - 250 | |
| 2417-FE04 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | AMEREX | B441 | SN107373 | C122A | CRITICAL | 01 Jan 1988 | 100.00 | EA | 500 LB | PSI - 250 | |
| 2417-FE05 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | AMEREX | B441 | SN107373 | C106 | CRITICAL | 01 Jan 1988 | 100.00 | EA | 500 LB | PSI - 250 | |
| 2417-FE06 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | AMEREX | B441 | SN107373 | C122 | CRITICAL | 01 Jan 1988 | 100.00 | EA | 500 LB | PSI - 250 | |
| 2417-FE07 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | A.O. SMITH | B441 | SN107373 | C141 | CRITICAL | 01 Jan 1988 | 100.00 | EA | 500 LB | PSI - 250 | |
| 2417-FE08 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | AMEREX | B441 | SN107373 | C153 | CRITICAL | 01 Jan 1988 | 100.00 | EA | 500 LB | PSI - 250 | |
| 2417-FE09 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | AMEREX | B441 | SN107373 | 137 | CRITICAL | 01 Jan 1988 | 100.00 | EA | 500 LB | PSI - 250 | |
| 2417-STDP-01 | FIRE PROTECTION SYSTEM | STANDPIPE SYSTEMS | <NA> | STANDPIPE EQUIPMENT & PIPING | UNKNOWN | UNKNOWN | UNKNOWN | 103 | CRITICAL | 01 Jan 1988 | 15.00 | ||||
| 2417-AHU01 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | AIR HANDLING UNIT | BOHN | UNKNOWN | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 2006 | 15.00 | BTU | 1 | FILTER - 12X24X2 (2); FILTER 1 - 24X24X2 (2) | |
| 2417-AHU01-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | AIR HANDLING UNIT MOTOR | DAYTON | 2YB78 | JT6089C34013 | 103 | NON-CRITICAL | 5.00 | |||||
| 2417-AHU02 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | AIR HANDLING UNIT | BOHN | HCL26BMF | BOD7096 | 101 | NON-CRITICAL | 01 Jan 2006 | 15.00 | BTU | 1 | BELT - B-81 (2); FILTER - 20X25X4(10); FILTER 1 - 16X25X4 (2); HERTZ - 60; PHASE - 3; VOLTS - 460 | |
| 2417-AHU02-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION, COOLING & HEATING | AIR HANDLING UNIT MOTOR | DAYTON | 2YB78 | JT6089C34013 | 101 | NON-CRITICAL | 21 Jul 2009 | 5.00 | HP | 25 | AMPS - 32; FRAME - 284T; HERTZ - 60; PHASE - 3; RPM - 1760; VOLTS - 460 | |
| 2417-CHWP01 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP | BALDOR | UNKNOWN | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | HP | 3 | AMPS - 9.5; HERTZ - 50 | |
| 2417-CHWP01-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP MOTOR | U.S. ELECTRICAL MOTORS | G156 | UNKNOWN | 101 | NON-CRITICAL | 01 Jan 1988 | 15.00 | HP | 3 | AMPS - 9.5-9.0/4.5; FRAME - 182JM; HERTZ - 60; PHASE - 3; RPM - 1730; VOLTS - 208-230/460 | |
| 2417-CHWP02 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP | BALDOR | UNKNOWN | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | HP | 3 | AMPS - 9.5; HERTZ - 50 | |
| 2417-CHWP02-M2 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP MOTOR | U.S. ELECTRICAL MOTORS | G156 | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | HP | 3 | AMPS - 9.5-9.0/4.5; FRAME - 182JM; HERTZ - 60; PHASE - 3; RPM - 1730; VOLTS - 208-230/460 | |
| 2417-ECP01 | HEATING, VENTILATION & AIR CONDITIONING | CONTROLS & INSTRUMENTATION | HVAC CONTROL | ELECTRICAL CONTROL PANEL | REVERE CONTROL SYSTEM | UNKNOWN | UNKNOWN | 101 | NON-CRITICAL | 01 Jan 1988 | 15.00 | AMPS - 59; HERTZ - 60; PHASE - 3; VOLTS - 480 | |||
| 2417-EF01 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | BALDOR | UNKNOWN | UNKNOWN | ROOF | NON-CRITICAL | 01 Jan 1988 | 15.00 | CFM | 8 | ||
| 2417-EF01-M1 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | A.O. SMITH | 323P764 | 12407ML | ROOF | NON-CRITICAL | 5.00 | BELT - 4L23; FRAME - 48Y | ||||
| 2417-EF02 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | BALDOR | UNKNOWN | UNKNOWN | ROOF | NON-CRITICAL | 01 Jan 1988 | 15.00 | CFM | 8 | ||
| 2417-EF02-M1 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | BALDOR | M3558T | PO71554437 | ROOF | NON-CRITICAL | 11 Jan 2008 | 5.00 | HP | 2 | BELT - A-33; FRAME - 48Y; PHASE - 3 | |
| 2417-EF03 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | BALDOR | UNKNOWN | UNKNOWN | ROOF | NON-CRITICAL | 01 Jan 1988 | 15.00 | CFM | 8 | ||
| 2417-EF03-M1 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | FASCO INDUST. INC. | 5-2API | 7164-0969 | ROOF | NON-CRITICAL | 11 Jan 2008 | 5.00 | BELT - A-33; FRAME - 48Y; PHASE - 1; RPM - 1550 | |||
| 2417-EF04 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | BALDOR | UNKNOWN | UNKNOWN | ROOF | NON-CRITICAL | 01 Jan 1988 | 15.00 | CFM | 8 | ||
| 2417-EF04-M1 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | A.O. SMITH | 323P64 | SAFI-P | ROOF | NON-CRITICAL | 01 Jan 2000 | 5.00 | PHASE - 1; RPM - 1375 | |||
| 2417-HWP01 | HEATING, VENTILATION & AIR CONDITIONING | HEAT GENERATING SYSTEM | STEAM BOILER | HEATING WATER RECIRCULATING PUMP | GENERAL ELECTRIC | 5K43MG8163A | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | HP | 1 | AMPS - 3.6-3.7/1.8; FRAME - 143JM; HERTZ - 60; PHASE - 3; RPM - 1725; VOLTS - 208-230/460 | |
| 2417-RC01 | HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CHILLED WATER SYSTEM | RECIPROCAL CHILLER | TRANE | RTAA0704XN01A3C0GN | U02K07071 | 103B | NON-CRITICAL | 01 Jan 1988 | 15.00 | AMPS - 133; FREON CHARGE - 58 LBS; FREON TYPE - R22; HERTZ - 60; PHASE - 3; VOLTS - 460 | |||
| 2417-RC01-C1 | HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CHILLED WATER SYSTEM | RECIPRICAL CHILLER COMPRESSOR | TRANE | CHHN035TKE0N043A | UA2K7094 | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | ||||
| 2417-RC01-C2 | HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CHILLED WATER SYSTEM | RECIPRICAL CHILLER COMPRESSOR | TRANE | CHHN035TKE0N043A | UA2K7094 | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | ||||
| 2417-RF01 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | RETURN FAN | PENN VENTILATION | UNKNOWN | M5157T | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | HP | 2 | AMPS - 2.4; BELT - A53 (1); VOLTS - 460 | |
| 2417-RF01-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | RETURN FAN MOTOR | BALDOR | UNKNOWN | UNKNOWN | 101 | NON-CRITICAL | 5.00 | |||||
| 2417-RF02 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | RETURN FAN | BALDOR | 4554-5T | UNKNOWN | 103 | NON-CRITICAL | 01 Oct 2006 | 15.00 | BELT - 5L770 (2) | |||
| 2417-RF02-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | RETURN FAN MOTOR | BALDOR | UNKNOWN | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 5.00 | HP | 10 | AMPS - 14; FRAME - 215T; HERTZ - 60; PHASE - 3; RPM - 1725; VOLTS - 460 | |
| 2417-TX-1 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | DAYTON | 316P759 | 13607J2 | ROOF | NON-CRITICAL | 5.00 | CFM | 8 | |||
| 2417-TX-1-M1 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | A.O. SMITH | 13607J2 | 316P759 | ROOF | NON-CRITICAL | 5.00 | HP | 1 | FRAME - 48 | ||
| 2417-TX-2 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | DAYTON | 3K6136 | N/A | ROOF | NON-CRITICAL | 5.00 | CFM | 8 | |||
| 2417-TX-2-M1 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | DAYTON | 3K6136 | N/A | ROOF | NON-CRITICAL | 5.00 | PHASE - 1; RPM - 1375 | ||||
| 2417-UH01 | HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER | STERLING | HS-36 | HS0661-88 | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | AMPS - .6; OTHER - STEAM; VOLTS - 115 | |||
| 2417-ACR01 | PLUMBING | PROCESS AIR SYSTEM | <NA> | PNEUMATIC AIR COMPRESSOR | DAYTON | 3Z853 | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | HP | 1.5 | PHASE - 1 | |
| 2417-ACR02 | PLUMBING | PROCESS AIR SYSTEM | <NA> | PNEUMATIC AIR COMPRESSOR | DAYTON | 3Z853 | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | HP | 1.5 | PHASE - 1 | |
| 2417-BFP01 | PLUMBING | DOMESTIC WATER SUPPLY | <NA> | BACKFLOW PREVENTER | CONBRACO | 909 | UNKNOWN | 103 | CRITICAL | 01 Jan 1988 | 15.00 | PSI - 175 | |||
| 2417-BFP-02 | PLUMBING | DOMESTIC WATER SUPPLY | <NA> | BACKFLOW PREVENTER | CONBRACO | 20002 | UNKNOWN | 103 | CRITICAL | 01 Jan 1988 | 15.00 | PSI - 65 | |||
| 2417-CAD01 | PLUMBING | PROCESS AIR SYSTEM | <NA> | INSTRUMENT AIR DRYER | HANKINSON | HPR5-10 | H510A1150312062 | 103 | CRITICAL | 01 Jan 1988 | 15.00 | FREON CHARGE - 3 OZ; FREON TYPE - R134A | |||
| 2417-DA01 | PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL AIR | INGERSOLLRAND | 0015 | 30T974436 | 103 | CRITICAL | 01 Jan 1988 | 15.00 | HP | 25 | PSI - 125 | |
| 2417-DA01-C1 | PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL AIR COMPRESSOR | INGERSOLLRAND | 0015 | 974447 | 103 | CRITICAL | 01 Jan 2004 | 15.00 | HP | 25 | PSI - 120 | |
| 2417-DA01-C2 | PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL AIR COMPRESSOR | INGERSOLLRAND | 0015 | 974436 | 103 | CRITICAL | 01 Jan 2004 | 15.00 | HP | 25 | PSI - 120 | |
| 2417-DA01-M1 | PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL AIR MOTOR | BALDOR | UNKNOWN | UNKNOWN | 101 | CRITICAL | 01 Jan 1988 | 15.00 | HP | 15 | AMPS - 39/19.5; FRAME - 254T; HERTZ - 60; PHASE - 3; RPM - 1760; VOLTS - 230/460 | |
| 2417-DA01-M2 | PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL AIR MOTOR | BALDOR | M2513T | UNKNOWN | 103 | CRITICAL | 01 Jan 1988 | 15.00 | HP | 15 | AMPS - 39/19.5; FRAME - 254T; HERTZ - 60; PHASE - 3; RPM - 1760; VOLTS - 230/460 | |
| 2417-DAD01 | PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL AIR DRYER | NEW EQUIPMENT | 5N12 | 99LG067 | 103 | CRITICAL | 01 Jun 1979 | 15.00 | HERTZ - 60; MAX PSI - 80; PHASE - 1; VOLTS - 120 | |||
| 2417-DF-01 | PLUMBING | PLUMBING FIXTURES | <NA> | DRINKING FOUNTAIN | ELKAY MFR CO. | UNKNOWN | UNKNOWN | 102A | NON-CRITICAL | 01 Jun 1979 | 15.00 | GPM | .5 | AMPS - 5.0; VOLTS - 115 | |
| 2417-DF-02 | PLUMBING | PLUMBING FIXTURES | <NA> | DRINKING FOUNTAIN | ELKAY MFR CO. | UNKNOWN | 102A | NON-CRITICAL | 01 Jun 1979 | 15.00 | GPM | .5 | AMPS - 5.0; VOLTS - 115 | ||
| 2417-DHWG01 | PLUMBING | DOMESTIC WATER SUPPLY | ELECTRIC HEATING ELEMENT | DOMESTIC WATER HEATER | NATIONAL BOARD | UNKNOWN | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | OTHER - STEAM | |||
| 2417-DV01 | PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL VACUUM PUMP SET | TECH WEST INC. | RESEARCH-UNKNOWN | DVC 20 3509 | 103 | NON-CRITICAL | 10.00 | |||||
| 2417-DV01-M1 | PLUMBING | MEDICAL GAS SYSTEM | <NA> | VACUUM PUMP MOTOR | GARDNER DENVER | 2BH1800-7AH26Z | 10026575015 | 103 | CRITICAL | 31 Dec 2008 | 10.00 | ||||
| 2417-DV01-M2 | PLUMBING | MEDICAL GAS SYSTEM | <NA> | VACUUM PUMP MOTOR | GARDNER DENVER | 2BH1800-7AH26Z | 10026575026 | 103 | CRITICAL | 31 Dec 2008 | 10.00 | ||||
| 2417-DV01-M3 | PLUMBING | MEDICAL GAS SYSTEM | <NA> | VACUUM PUMP MOTOR | GARDNER DENVER | 2BH1800-7AH26Z | 10026575016 | 103 | CRITICAL | 31 Dec 2008 | 10.00 | ||||
| 2417-DV01-M4 | PLUMBING | MEDICAL GAS SYSTEM | <NA> | VACUUM PUMP MOTOR | GARDNER DENVER | 2BH1800-7AH26Z | 10026575020 | 103 | CRITICAL | 31 Dec 2008 | 10.00 | ||||
| 2417-DV02 | PLUMBING | DENTAL GAS SYSTEM | <NA> | DENTAL VACUUM PUMP SET | TECH WEST INC. | RESEARCH-UNKNOWN | DUC 20 3508 | 101 | NON-CRITICAL | 10.00 | |||||
| 2417-RPH01 | PLUMBING | DOMESTIC WATER SUPPLY | <NA> | DOMESTIC HOT WATER PUMP | BELL & GOSSETT | 106197 | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | ||||
| 2417-SP01 | PLUMBING | SANITARY WASTE & VENT SYSTEM | <NA> | SUMP PUMP | PROSSER/ENPO | 300L4-8T-06E-006 | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | ||||
| 2417-SP02 | PLUMBING | SANITARY WASTE & VENT SYSTEM | <NA> | SUMP PUMP | PROSSER/ENPO | 300L4-8T-06E-006 | UNKNOWN | 103 | NON-CRITICAL | 01 Jan 1988 | 15.00 | ||||
| 103 | |||||||||||||||
| 03457 - BIO ENVIRONMENTAL/PUBLIC HEALTH | |||||||||||||||
| RPIE ID | Facility System(RPIE Details) | Facility Subsystem(RPIE Details) | Assembly Category(RPIE Details) | Nomenclature(RPIE Details) | Manufacturer Name | Model Number | Manufacturer Serial Number | Room # | Other Location | Risk Factor | Installation Date | Life Expectancy | Capacity Unit | Capacity Value | Spec Data (All in Single Cell) |
| 3457-AV01-13 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | AUDIO VISUAL ALARM | UNKNOWN | UNKNOWN | UNKNOWN | THROUGHOUT FACILITY | CRITICAL | 01 Jan 1999 | 20.00 | ||||
| 3457-DSD01 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | DUCT SMOKE DETECTOR | SYSTEM SENSOR | DH100ACDCI | UNKNOWN | 123 | CRITICAL | 09 Jan 1999 | 20.00 | ||||
| 3457-FS01 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | FLOW SWITCH | UNKNOWN | VSR-F | UNKNOWN | 123 | CRITICAL | 09 Jan 1999 | 20.00 | ||||
| 3457-FS02 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | FLOW SWITCH | UNKNOWN | VSR-F | UNKNOWN | 123 | CRITICAL | 09 Jan 1999 | 20.00 | ||||
| 3457-HD01 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | HEAT DETECTOR | UNKNOWN | UNKNOWN | UNKNOWN | 125 | CRITICAL | 09 Jan 1999 | 20.00 | ||||
| 3457-MAP01 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | MAIN ANNUNCIATOR PANEL | MONACO | 227-551-12 | 04/00 | 125 | CRITICAL | 09 Jan 1999 | 20.00 | AMPS - 2.5/1.25; HERTZ - 48/62; VOLTS - 120/240; WATTS - 300/300 | |||
| 3457-PS01-03 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | PULL STATION | UNKNOWN | UNKNOWN | UNKNOWN | THROUGHOUT FACILITY | CRITICAL | 01 Jan 1999 | 20.00 | ||||
| 3457-TS01-3 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | TAMPER SWITCH | UNKNOWN | UNKNOWN | UNKNOWN | THROUGHOUT FACILITY | CRITICAL | 09 Jan 1999 | 20.00 | ||||
| 3457-TS01-4 | ALARM, SECURITY AND BUILDING MANAGEMENT SYSTEM | FIRE ALARM SYSTEM | <NA> | TAMPER SWITCH | UNKNOWN | UNKNOWN | UNKNOWN | THROUGHOUT FACILITY | CRITICAL | 09 Jan 1999 | 20.00 | ||||
| 3457-DS01 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | DISCONNECT SWITCH | SIEMENS | GNF322R | UNKNOWN | OUTSIDE | NON-CRITICAL | 09 Jan 1999 | 20.00 | EA | 1 | AMPS - 60; HERTZ - 60; PHASE - 3; VOLTS - 240 | |
| 3457-MDP01 | ELECTRICAL POWER & DISTRIBUTION | PRIMARY POWER | MAIN SWITCHBOARD | MAIN DISTRIBUTION PANEL | SQUARE D | 1212195217003 | UNKNOWN | 125 | NON-CRITICAL | 09 Jan 1999 | 20.00 | EA | 1 | AMPS - 600; HERTZ - 60; PHASE - 3; VOLTS - 208/120 | |
| 3457-MSD01 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | ENCLOSED CIRCUIT BREAKER | MOTOR STARTER DISCONNECT | UNICO | 1100-230-010-C-N-F00 | XH1107 | 123 | NON-CRITICAL | 01 Jan 2000 | 20.00 | EA | 1 | AMPS - V45/36C; HERTZ - 60; PHASE - 3; VOLTS - 230 | |
| 3457-MSD02 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | ENCLOSED CIRCUIT BREAKER | MOTOR STARTER DISCONNECT | SQUARE D | UNKNOWN | 3671016001 | 123 | NON-CRITICAL | 01 Jan 1999 | 20.00 | EA | 1 | AMPS - 30; HERTZ - 60; PHASE - 3; VOLTS - 200-230/460 | |
| 3457-MSD03 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | ENCLOSED CIRCUIT BREAKER | MOTOR STARTER DISCONNECT | SQUARE D | UNKNOWN | 3671016009 | 123 | NON-CRITICAL | 01 Jan 1999 | 20.00 | EA | 1 | AMPS - 30; HERTZ - 60; VOLTS - 200-230/460 | |
| 3457-MSD04 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | ENCLOSED CIRCUIT BREAKER | MOTOR STARTER DISCONNECT | SQUARE D | UNKNOWN | 36710160021 | 124 | NON-CRITICAL | 01 Jan 1999 | 20.00 | EA | 1 | AMPS - 30; HERTZ - 60; PHASE - 3; VOLTS - 200-230/460 | |
| 3457-MSD05 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | ENCLOSED CIRCUIT BREAKER | MOTOR STARTER DISCONNECT | SQUARE D | UNKNOWN | 36710160021 | 124 | NON-CRITICAL | 01 Jan 1999 | 20.00 | EA | 1 | AMPS - 30; HERTZ - 60; VOLTS - 200-230/460 | |
| 3457-PLRA | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SQUARE D | NQOD | 12195217006 | 125 | NON-CRITICAL | 09 Jan 1999 | 20.00 | EA | 1 | AMPS - 225; HERTZ - 60; PHASE - 3; VOLTS - 208/120 | |
| 3457-PLRB | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SQUARE D | NQOD | 12195217004 | 125 | NON-CRITICAL | 09 Jan 1999 | 20.00 | EA | 1 | AMPS - 225; HERTZ - 60; PHASE - 3; VOLTS - 208/120 | |
| 3457-PLRC | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SQUARE D | NQOD | 12195217005 | 125 | NON-CRITICAL | 09 Jan 1999 | 20.00 | EA | 1 | AMPS - 225; HERTZ - 60; PHASE - 3; VOLTS - 208/120 | |
| 3457-PLRL | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | PANEL BOARD | SUBPANEL | SQUARE D | NQOD | 12195217007 | 125 | NON-CRITICAL | 09 Jan 1999 | 20.00 | EA | 1 | AMPS - 225; HERTZ - 60; PHASE - 3; VOLTS - 208/120 | |
| 3457-VFD01 | ELECTRICAL POWER & DISTRIBUTION | SECONDARY POWER | <NA> | VARIABLE FREQUENCY DRIVE | YASKAWA | CIMR-P7U 2015 | 1W06277069 20010 | 123 | NON-CRITICAL | 01 Mar 2006 | 20.00 | AMPS - 70; HERTZ - 60; PHASE - 3; VOLTS - 200-240 | |||
| 3457-LTNGPROT | ELECTRICAL SYSTEM | LIGHTNING PROTECTION SYSTEM | <NA> | LIGHTNING PROTECTION | UNKNOWN | UNKNOWN | UNKNOWN | OUTSIDE | NON-CRITICAL | 09 Jan 1999 | 100.00 | ||||
| 3457-EL01-12 | EMERGENCY POWER & LIGHTING | EMERGENCY LIGHTING | EGRESS LIGHTING | EXIT LIGHT | UNKNOWN | UNKNOWN | UNKNOWN | THROUGHOUT FACILITY | CRITICAL | 09 Jan 1999 | 20.00 | EA | 12 | ||
| 3457-BLDG-EXT | EXTERIOR CLOSURE | EXTERIOR WALL | EXTERIOR LOUVER AND SCREEN | BUILDING EXTERIOR | PENN VENTILATION | DC COMBINATION | UNKNOWN | OUTSIDE | CRITICAL | 09 Jan 1999 | 100.00 | FRAME - 22.75X22.75 | |||
| 3457-FAS | FIRE PROTECTION SYSTEM | SPRINKLERS | <NA> | FIRE ALARM SYSTEM | UNKNOWN | UNKNOWN | UNKNOWN | THROUGH OUT | NON-CRITICAL | 09 Jan 1999 | 100.00 | ||||
| 3457-FDC01 | FIRE PROTECTION SYSTEM | STANDPIPE SYSTEMS | <NA> | FIRE DEPARTMENT CONNECTION | UNKNOWN | AUTOSPKR300 | UNKNOWN | OUTSIDE | EXTERIOR | CRITICAL | 09 Jan 1999 | 15.00 | |||
| 3457-FDC02 | FIRE PROTECTION SYSTEM | STANDPIPE SYSTEMS | <NA> | FIRE DEPARTMENT CONNECTION | UNKNOWN | AUTOSPKR300 | UNKNOWN | OUTSIDE | CRITICAL | 09 Jan 1999 | 15.00 | ||||
| 3457-FE01 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | AMEREX | B456 | UNKNOWN | C1 | CRITICAL | 09 Jan 1999 | 100.00 | ||||
| 3457-FE02 | FIRE PROTECTION SYSTEM | FIRE EXTINGUISHING DEVICES | DRY CHEMICAL EXTINGUISHING SYSTEM | PORTABLE FIRE EXTINGUISHER | AMEREX | B456 | UNKNOWN | 123 | CRITICAL | 09 Jan 1999 | 100.00 | ||||
| 3457-SPRH-ALL | FIRE PROTECTION SYSTEM | SPRINKLERS | <NA> | SPRINKLER SYSTEM | UNKNOWN | UNKNOWN | UNKNOWN | THROUGHOUT FACILITY | CRITICAL | 09 Jan 1999 | 10.00 | ||||
| 3457-STDP-001 | FIRE PROTECTION SYSTEM | STANDPIPE SYSTEMS | <NA> | STANDPIPE EQUIPMENT & PIPING | CENTRAL-STEEL PIPE | ASTM | UNKNOWN | 123 | CRITICAL | 09 Jan 1999 | 20.00 | ||||
| 3457-STDP-002 | FIRE PROTECTION SYSTEM | STANDPIPE SYSTEMS | <NA> | STANDPIPE EQUIPMENT & PIPING | CENTRAL-STEEL PIPE | ASTM | UNKNOWN | 123 | CRITICAL | 09 Jan 1999 | 20.00 | ||||
| 3457-AHU01 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | AIR HANDLING UNIT | YORK INTERNATIONAL | AP215 | CGHM00553C | 123 | EXT MECH RM 123 | NON-CRITICAL | 09 Jan 1999 | 15.00 | AMPS - 44.4; HERTZ - 60; PHASE - 3; VOLTS - 200 | ||
| 3457-AHU01-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION, COOLING & HEATING | AIR HANDLING UNIT MOTOR | MAGNETEK | E464 | N/A | 123 | EXT MECH RM 123 | NON-CRITICAL | 09 Jan 1999 | 15.00 | HP | 15 | AMPS - 44.4; FRAME - D264T; RPM - 1750; VOLTS - 200 |
| 3457-B01 | HEATING, VENTILATION & AIR CONDITIONING | HEAT GENERATING SYSTEM | HOT WATER BOILER (SPACE HEATING) | BOILER HOT WATER | WEIL-MCLAIN | PFG-7-PIN | SERIES 6 | 124 | NON-CRITICAL | 09 Jan 1999 | 15.00 | BTU | 366000 | HERTZ - 60; MAX PSI - 50; PHASE - 1; VOLTS - 120 | |
| 3457-CHWP01 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP | BELL & GOSSETT | 1531-S 1:5 BC 7.125B | 2202956A00 | 123 | EXT MECH RM 123 | CRITICAL | 25 Jan 2006 | 15.00 | HP | 3 | GPM - 75 |
| 3457-CHWP01-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CHILLED WATER PUMP MOTOR | U.S. ELECTRICAL MOTORS | B028A | UNKNOWN | 123 | EXT MECH RM 123 | NON-CRITICAL | 09 Jan 1999 | 15.00 | HP | 3.0 | AMPS - 208/230-460; FRAME - 182JP; HERTZ - 60; PHASE - 3; RPM - 1745; VOLTS - 9.6/8.4-4.2 |
| 3457-CP01 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CIRCULATING PUMP | TACO | 006-BT4 | UNKNOWN | 124 | NON-CRITICAL | 09 Jan 1999 | 15.00 | AMPS - .5; HERTZ - 60; MAX PSI - 125; PHASE - 1; VOLTS - 115 | |||
| 3457-CP01-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | CHILLED WATER DISTRIBUTION SYSTEM | CIRCULATING PUMP MOTOR | 124 | NON-CRITICAL | |||||||||
| 3457-EF01 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | PENN VENTILATION | REX 128 | S48C78A01 | 100 | 1ST FLOOR CEILING NT 120 | NON-CRITICAL | 01 Jan 1999 | 15.00 | HP | 1/2 | PHASE - 1 |
| 3457-EF01-M1 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | MOTOR MARATHON | SKH33JN3121 | UNKNOWN | 100 | 1ST FLOOR CEILING NT 120 | NON-CRITICAL | 5.00 | ||||
| 3457-EF02 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN | UNKNOWN | PVH16 | 101165002 | 124 | NON-CRITICAL | 21 Sep 2009 | 8.00 | ||||
| 3457-EF02-M1 | HEATING, VENTILATION & AIR CONDITIONING | EXHAUST & VENTILATION SYSTEM | <NA> | EXHAUST FAN MOTOR | MOTOR MARATHON | SKH33JN3121 | UNKNOWN | 102 | NON-CRITICAL | 5.00 | FRAME - 48; RPM - 1725 | ||||
| 3457-ET01 | HEATING, VENTILATION & AIR CONDITIONING | ENERGY SUPPLY | HOT WATER SUPPLY SYSTEM | EXPANSION TANK | UNKNOWN | WXTP-18 | UNKNOWN | 124 | NON-CRITICAL | 01 Jan 1999 | 15.00 | GALLONS - 4.5; MAX PSI - 150; OTHER - MAXTEMP 200 | |||
| 3457-HWP01 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | HOT WATER DISTRIBUTION SYSTEM | HOT WATER PUMP | U.S. ELECTRICAL MOTORS | 1.25 6.75 BF | 2204089-A00 | 124 | NON-CRITICAL | 09 Jan 1999 | 15.00 | GPM | 30 | RPM - 1800 | |
| 3457-HWP01-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | HOT WATER DISTRIBUTION SYSTEM | HOT WATER PUMP MOTOR | U.S. ELECTRICAL MOTORS | F133 | UNKNOWN | 124 | NON-CRITICAL | 09 Jan 1999 | 15.00 | HP | 2 | AMPS - 6.2/3.1; FRAME - 145JP; HERTZ - 60; RPM - 1725; VOLTS - 208-230/460; PHASE - 3 | |
| 3457-HWP02 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | HOT WATER DISTRIBUTION SYSTEM | HOT WATER PUMP | U.S. ELECTRICAL MOTORS | 1.25 6.75 BF | 2204090 | 124 | NON-CRITICAL | 09 Jan 1999 | 15.00 | GPM | 30 | RPM - 1800 | |
| 3457-HWP02-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | HOT WATER DISTRIBUTION SYSTEM | HOT WATER PUMP MOTOR | U.S. ELECTRICAL MOTORS | F133 | UNKNOWN | 124 | NON-CRITICAL | 09 Jan 1999 | 15.00 | HP | 2 | AMPS - 6.2/3.1; FRAME - 145JP; HERTZ - 60; PHASE - 3; RPM - 1725; VOLTS - 208-230/460 | |
| 3457-RC01 | HEATING, VENTILATION & AIR CONDITIONING | COOLING GENERATING SYSTEMS | CHILLED WATER SYSTEM | RECIPROCAL CHILLER | YORK INTERNATIONAL | YCAL0034SC17XAA | SBJM883693 | OUTSIDE | EXTERIOR | NON-CRITICAL | 09 Jan 1999 | 15.00 | AMPS - 183; FREON CHARGE - 69 LBS; FREON TYPE - R22; GALLONS - 3117 LBS; HERTZ - 60; MAX PSI - 450; PHASE - 3; VOLTS - 200 | ||
| 3457-SF01 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | SUPPLY FAN | PENN VENTILATION | REX 14B | PS072226 | 123 | NON-CRITICAL | 09 Jan 1999 | 15.00 | HERTZ - 60; PHASE - 1; VOLTS - 220 | |||
| 3457-SF01-M1 | HEATING, VENTILATION & AIR CONDITIONING | DISTRIBUTION SYSTEMS | AIR DISTRIBUTION DUCTWORK & DEVICES | SUPPLY FAN MOTOR | UNKNOWN | UNKNOWN | UNKNOWN | 123 | NON-CRITICAL | 09 Jan 1999 | 15.00 | ||||
| 3457-UH01 | HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER | STERLING | HS-125AS | C99S002829 | 123 | NON-CRITICAL | 01 Jan 1999 | 15.00 | CFM | 590 | AMPS - 1.1; HERTZ - 60; MAX PSI - 250; PHASE - 1; VOLTS - 115 | |
| 3457-UH01-M1 | HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER MOTOR | STERLING | H8-256S | C938002928 | 123 | NON-CRITICAL | 01 Jan 1999 | 10.00 | ||||
| 3457-UH02 | HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER | STERLING | HS-125AS | C99S002827 | 124 | NON-CRITICAL | 09 Jan 1999 | 15.00 | CFM | 590 | AMPS - 1.1; HERTZ - 60; MAX PSI - 250; PHASE - 1; VOLTS - 115 | |
| 3457-UH02-M1 | HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER MOTOR | STERLING | H8-256S | C938002928 | 124 | NON-CRITICAL | 09 Jan 1999 | 10.00 | ||||
| 3457-UH03 | HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER | TPI | F3483T281RCH3T2 | UNKNOWN | 1ST FLR MAIN ENTRANCE | NON-CRITICAL | 09 Jan 1999 | 15.00 | VOLTS - 208; HERTZ - 60; PHASE - 1; WATTS - 3000 | |||
| 3457-UH03-M1 | HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER MOTOR | STERLING | H8-256S | C938002928 | 1ST FLR MAIN ENTRANCE | NON-CRITICAL | 10.00 | |||||
| 3457-UH04 | HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER | TPI | F3483T281RCH3T2 | UNKNOWN | 1ST FLR REAR ENTRANCE | NON-CRITICAL | 09 Jan 1999 | 15.00 | HERTZ - 60; PHASE - 1; VOLTS - 208; WATTS - 3000 | |||
| 3457-UH04-M1 | HEATING, VENTILATION & AIR CONDITIONING | TERMINAL AND PACKAGED UNIT | <NA> | UNIT HEATER MOTOR | STERLING | H8-256S | C938002928 | 1ST FLR REAR ENTRANCE | NON-CRITICAL | 10.00 | |||||
| 3457-BFP01 | PLUMBING | DOMESTIC WATER SUPPLY | <NA> | BACKFLOW PREVENTER | ZURN/WILKINS | 975XL | 920437 | 124 | CRITICAL | 09 Jan 1999 | 15.00 | MAX PSI - 175 | |||
| 3457-BFP03 | PLUMBING | DOMESTIC WATER SUPPLY | <NA> | BACKFLOW PREVENTER | ZURN/WILKINS | 975XL | UNKNOWN | 124 | CRITICAL | 09 Jan 1999 | 15.00 | MAX PSI - 175 | |||
| 3457-DF01 | PLUMBING | PLUMBING FIXTURES | <NA> | DRINKING FOUNTAIN | ELKAY MFR CO. | EBFSAB1D | 991013985 | 122 | NON-CRITICAL | 09 Jan 1999 | 15.00 | AMPS - 5; FREON CHARGE - 4 OZ; FREON TYPE - 134A; HERTZ - 60; MAX PSI - 140; PHASE - 1; VOLTS - 115 | |||
| 3457-DHWG01 | PLUMBING | DOMESTIC WATER SUPPLY | OIL OR GAS FIRED | DOMESTIC WATER HEATER | A.O. SMITH | BTR120 | MJ990869838 | 124 | NON-CRITICAL | 09 Jan 1999 | 15.00 | AMPS - 5; HERTZ - 60; MAX PSI - 160; OTHER - NATURAL GAS; VOLTS - 120 |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .