Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE

PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION

NO.

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.

IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

NSN 7540-01-152-8070

Previous edition unusable

5P2PQ

GS-05P-P-16-FD-C-7000 -Construction Manager as Constructor, for 536 S. Clark Street 9th Floor Build-out; Amendmend to Solicitation 003.

See Continuation Page

Acquisition Management Division 230 S. Dearborn St.

Room 3600 Chicago, IL 60604

See Block 6

GS-05P-P-16-FD-C-7000

1 279

1/6/2016

INSTRUCTIONS

Instructions for items other than those that are self-explanatory, are as follows:

Item 1 (Contract ID Code). Insert the contract type identification code that appears in the title block of the contract being modified.

Item 3 (Effective date).

(1)

(2)

(3)

(4)

(5)

For a solicitation amendment, change order, or administrative change, the effective date shall be the issue date of the amendment, change order, or administrative change.

For a supplemental agreement, the effective date shall be the date agreed to by the contracting parties.

For a modification issued as an initial or confirming notice of termination for the convenience of the Government, the effective date and the modification number of the confirming notice shall be the same as the effective date and modification number of the initial notice.

For a modification converting a termination for default to a termination for the convenience of the Government, the effective date shall be the same as the effective date of the termination for default.

For a modification confirming the contacting officer's determination of the amount due in settlement of a contract termination, the effective date shall be the same as the effective date of the initial decision.

(a)

(b)

(c)

(d)

(e)

(f)

Item 6 (Issued By). Insert the name and address of the issuing office. If applicable, insert the appropriate issuing office code in the code block.

Item 8 (Name and Address of Contractor). For modifications to a contract or order, enter the contractor's name, address, and code as shown in the original contract or order, unless changed by this or a previous modification.

Item 9, (Amendment of Solicitation No. - Dated), and 10, (Modification of Contract/Order No. - Dated). Check the appropriate box and in the corresponding blanks insert the number and date of the original solicitation, contract, or order.

Item 12 (Accounting and Appropriation Data).

When appropriate, indicate the impact of the modification on each affected accounting classification by inserting one of the following entries.

(2) Accounting classification Net decrease $

Include subject matter or short title of solicitation/contract where feasible.

Item 16B. The contracting officer's signature is not required on solicitation amendments. The contracting officer's signature is normally affixed last on supplemental agreements.

(i)

NOTE: If there are changes to multiple accounting classifications that cannot be placed in block 12, insert an asterisk and the words "See continuation sheet".

Item 13. Check the appropriate box to indicate the type of modification. Insert in the corresponding blank the authority under which the modification is issued. Check whether or not contractor must sign this document. (See FAR 43.103.)

Item 14 (Description of Amendment/Modification).

Organize amendments or modifications under the appropriate Uniform Contract Format (UCF) section headings from the applicable solicitation or contract. The UCF table of contents, however, shall not be set forth in this document

Indicate the impact of the modification on the overall total contract price by inserting one of the following entries:

(i) Total contract price increased by $

(ii) Total contract price decreased by $

(iii) Total contract price unchanged.

State reason for modification.

When removing, reinstating, or adding funds, identify the contract items and accounting classifications.

(g)

(h)

When the SF 30 is used to reflect a determination by the contracting officer of the amount due in settlement of a contract terminated for the convenience of the Government, the entry in Item 14 of the modification may be limited to --

(i) A reference to the letter determination; and

(ii) A statement of the net amount determined to be due in settlement of the contract.

(1)

(2)

(3)

(4)

(5)

(6)

STANDARD FORM 30 (REV. 10-83) BACK

(1) Accounting classification Net increase $

Continuation Page

GS-05P-P-16-FD-C-7000 – Construction Manager as Constructor, for the 536 S. Clark Street 9th Floor Build-out Project; Amendment to Solicitation 003 – Responses to Questions Received.

This Amendment to Solicitation, 003, is hereby issued to incorporate/provide the following:

1. Second Set of Contractor Questions with attachments for questions 17 and 35

All other terms and conditions shall remain unchanged.

1. Please confirm we can include an electronic copy of our proposal on a CD with our submission in lieu of emailing it.

-The proposal should not be emailed. Electronic submittals via email will not be accepted. Additionally, a CD will not be accepted. For the purpose of review, we need hard copies.

2. Please confirm the 527 form should be included in the Price volume -Yes, GSA Form 527 should be included in the price volume.

3. In which volume, Technical or Price, should we include our joint venture agreement?

-Joint venture agreement should be included in the Technical Proposal, under a separate tab.

4. Solicitation, page 6 item IIB 1st paragraph states to submit 1 original and 5 copies of both the technical and price proposals… 2nd paragraph states … two sealed envelopes, one to contain one original and seven copies of the technical proposal… and the other to contain one original and five copies of the price proposal…. Please confirm number of copies of price and technical that should be submitted.

-The number seven is a typo. There will be two envelopes, one for price and one for technical. In each envelope (Technical and Price) there will be six proposals, one original and five copies. No electronic submittal is required.

5. On page 12, II.F.(4) of the Solicitation under Requirements for Joint Venture Offerors it states “Representations and certifications, financial information, and past performance information must be submitted for each member of the joint venture. Do we need to include 3 projects for the JV or 3 each for the JV partner for Factor 1 for a total of 6 projects and the same corresponding references for those 6 projects?

-For past performance, if you have 3 projects on which you worked together as a joint venture, and which meet the criteria in the Request for Proposal, please submit those. If you do not have that, then please submit three for each of the JV partners, for a total of 6 projects.

6. The “suggested team member staffing” is listed in the Solicitation on page 7, under Staffing Plan and page 9 under Qualification & Experience of Key Personnel, however, it is NOT the same list in each section. Please confirm the “suggested staffing” we should include.

-The lists are just samples, you will include what you feel is needed in order to complete the Scope of Work on time and on budget.

7. There are a lot of required staff - do resumes count in the 30 double sided page limit?

-No, resumes do not count towards the 30 pages.

8. Solicitation, page 8 - Quality Control Plan states “provide an example of the detailed QCP…” Can we submit a summary of our plan that addresses the items noted in the RFP and include a sample plan as an exhibit that doesn’t count in the 30 double sided page limit for the management approach?

-Yes, you can submit a sample Quality Control Plan as an attachment, which will not count towards the page requirement. The summary, pertaining to this project, will count towards the 30 pages.

9. Solicitation, page 8 - Safety Plan states “Provide a safety plan that demonstrates firm’s approach…” Our safety plan is over 100 pages, please confirm this does not count in the 30 double sided page limit for the management approach.

-Your company’s safety plan may be an attachment and will not count towards the 30 page requirement.

10. Page 013100-4 identifies a Waste Management Coordinator. That position is not identified in either of the places in the RFP that identify staff. Please clarify if that Position/Role is required.

-In the RFP, the positions/roles identified are just examples. Please provide the key personnel which you think is needed to perform the work.

11. Drawings E206 and 207 reference that fire alarm devices and terminal cabinets to be by others; What is the CMc’s responsibility regarding fire alarm infrastructure, devices, equipment, testing and commissioning other than coordination?

-CMc will be responsible for cooperating and coordination with Fire alarm contractor hired under a separate contract

12. Sheet G000 in Amendment No. 1 added sheets AD102 and AD103 (Demolition Floor Plans) to the Drawing Index. These sheets are not included in the amendment. Please advise.

-These sheets are part of Amendment to Solicitation 001 and they were uploaded to WWW.FBO.GOV as separate attachments. Please look at all of the items uploaded along with the Amendment.

13. In the Project Specifications, on page 011400-2 (page 14 of the .pdf) working hours are defined as 6am to 6pm. On page 011400-2 (page 100 of the .pdf) working hours are defined as 7am to 5pm. Please clarify the working hours.

-Normal Business (working) hours are from 7:30 a.m. to 5:00 p.m.

14. SHEET A204; Adjudication #9031 calls for the LVT 1 & LVT 2. Corridor #9011 call for CPT-1. Where is the break between the 2 areas?

-Flooring for 9031 has been revised to CPT-1 with VB-2 as the wall base.

15. SHEET A204; Adjudication #9048 calls for the LVT 1 & LVT 2. Corridor #9057 calls for only LVT-1. Where is the break between these 2 areas?

-Flooring for 9048 has been revised to CPT-1 with VB-2 as the wall base.

16. Please advise spec details for LVT1 and for LVT-2. I wasn’t able to find these in the manual.

DESCRIPTION MFR. (OR APPROVED EQUAL) REMARKS

LVT-1: Luxury Vinyl Tile ; Patcraft 7”x48” Plank, 20 Mil ; Style: Click Refresh1600V \ Color:

TBD

LVT-2: Luxury Vinyl Tile ; Patcraft 7”x48” Plank, 20 Mil ; Style: Click Refresh1600V \ Color:

TBD

17. Please quantify how much LBP and ACM abatement should be included in our proposal, if at all.

The locations and quantities shown in these reports should be considered the same for the 9th floor

- See attached Reports, separate documents

- Spec Sec. 02 086

- 2014.11.4 Bulk Sample Results

- 2014.11.13 TEM Bulk Results

- 2014.11.14 Bulk Sample Results

- A14-15825-Lab Report

- A14-17550 - Lab Report

- 2015.11.18 Pre Renovation ACM (8th)

- 2015.12.3 ACM & LBP Survey (7th)

- IL0055 536 Asbestos & LBP - Updated 5-11-15

- 2015.11.9 Lead Based Paint Survey

18. The FP demolitions plans (FD211 & FD212) indicate 220 sprinkler heads to be eliminated while FP plans (F211 & F212) indicate 10 sprinkler heads to be installed. If we are go per plan, we are leaving about 95% of the area unprotected. Please clarify on your intention for the sprinkler piping system in the space.

-The entire floor gets new sprinklers. Refer to the 65% drawings for the proposed layout.

19. In looking at the Door Schedule (A901) the hardware schedule is missing. The specs only tell us the manufactures to use but not the hardware sets for each opening.

-A hardware schedule will be provided in the next submission.

20. What fire alarm system is currently in the building?

-The existing system is Gamewell 650.

21. Drawing A100 shows a 3d view of the entire Ground and Ninth floors. Please confirm that upon Award Revit model file used to generate that will be provided as a starting point for us to complete the drawings from.

- Revit model project file will be provided.

22. Please clarify the full scope and what the expectations are for completing the design portion of work associated with the Ground Floor.

- The full scope of work will be provided in follow on drawings. Contractor is to provide gMP pricing based on information contained in the 65% Construction Drawing documents.

23. Walking the Ninth Floor, looking up, what looks like glass drain pipe could be seen in many locations. Demolition in this vicinity will require special care. Please confirm what materials pass thru this pipe.

- As identified by EPA, there are no health risks associated with the contents of the glass pipe or neutralization basins in the mechanical rooms.

24. At cL D / 15 and at cL B / 14 ramps exist that appear to go from the top of structural slab to a higher level made by pedestal supported raised access flooring. Near cL D / 15 there is not demolition called for of existing partitions. Near cL B / 14 all the existing partitions are shown to be removed. Please clarify two things:

a. What partitions start at top of structural slab versus which are built on top of the raised access flooring.

Ans- Existing partition analysis at existing raised flooring will be included in the next submission.

b. Confirm the limits of raised access flooring demolition.

Ans -Extent of existing raised flooring demolition will be included in the next submission.

25. What is the A/E’s (DOR) SOW and design schedule to allow for monitoring of A/E progress per Solicitation p9 111.D.1 and SOW p 32.3.4.2.

- AE will provide 100% CD's shortly after the CMc contract is awarded.

26. SOW p 32.3.4.4 is this still applicable or is the design phase at a higher level of percent complete? At what level is the design to be at CMc Award?

- 65% Construction Drawings have been provided. These will be the drawings on which the CMc award will be made, no additional drawings will be provided at this time.

Pricing should be provided based on the 65% Construction Drawings.

27. AD102 & AD103 – Keynotes D1 & D2 are repeated w/in the note itself; Is there to be other information provided within these notes for different types of flooring?

-Repeated note will be removed in Keynotes D1 and D2. No other information is to be provided within these notes.

28. A202 & A03 – Keynote for Note #30 & #31 are the same, but Keynote #31 is located in D.S.

Hub & Network Rooms, please clarify

- Keynote 31 to read: NO MECHANICAL EQUIPMENT SHALL BE INSTALLED ABOVE NETWORK HUB OR D.S. HUB. Keynote 30 to remain as indicated.

29. A202 & A203 – Doors

a. Door into Supply Rm 9067 not defined

- 3'-0"Wx7'-0" Type C door: Type 1 Frame

b. Door into Public Entry Rm 9001 not defined -Door 9001A will be door type F, the same glass wall system with door in Meeting Room 9019

c. Door 111GG not shown on drawings -Door 111GG will be indicated as 9070A. Door and frame is to match existing.

d. Door 9019LLLL not shown on drawing -Door 9019LLLL will be indicated as 9002A

30. 16 Please provide a legend for the architecture drawings as it relates to drawings A204 and A205. Many of the symbols utilized do not match up with other symbols utilized elsewhere.

-A symbols list will be provided with the next submission.

31. A410 – Callouts for plumbing fixtures P1-P4 do not match plumbing schedule nomenclature on P601.

-Refer to Plumbing drawing sheet P601 for specified fixture callouts. Fixtures will be generically indicated on A410 .

32. What are the finishes for Corridor 9000? Nothing is shown on the Finish Schedule?

-Existing finishes to remain along Corridor 9000. Patch existing finishes as required along new partition. Paint finish and wall base to match existing adjacent.

33. The Reflected ceiling plan (A204) shows acoustic ceiling in the Men’s and Women’s restrooms but the Finish schedule indicates that it is a drywall ceiling. Please clarify.

-Provide drywall ceilings for the Men's and Women's restrooms.

34. General Note #1 on A202 & A203. Where is “the location of the 8 mil shatter resistant glass at all windows”? Do they mean for the new interior office and door sidelite windows or existing perimeter windows?

- All existing perimeter windows in the tenant space to receive 8MIL shatter resistant film applied per mfr's. instructions and GSA requirements.

35. They call for building standard signage. What is the building standard and will a sign be installed at every room?

- Yes, provide a sign for every room. See attachment for description.

36. There still is not a door hardware schedule. The general notes on A901 indicate the GC is to provide non-locking hardware, closers, hinges, etc and DOS will provide the locking hardware.

What doors will get the non-locking hardware so we know what needs to be estimated?

-A door hardware schedule will be provided in the next submission.

37. What is the door type for the double doors and 9001? The drawing looks like it might be glass with glass sidelites. Also, the door number is not indicated on the door schedule now.

-Door 9001A will be door type F, the same glass wall system with door in Meeting Room 9019.

38. What is the specification for LVT-1, LVT-2, VCT-1 and SDT-1? I have looked in the Spec book and did not see anything. All there is a spec for is Rubber Floor tile and that isn’t indicated on the Finish Schedule.

LVT-1: Luxury Vinyl Tile Patcraft 7”x48” Plank, 20 Mil Style: Click Refresh1600V \ Color: TBD. LVT-2: Luxury Vinyl Tile Patcraft 7”x48” Plank, 20 Mil Style: Click Refresh1600V \ Color: TBD.

VCT-1: Armstrong 12"x12" Safety Zone, Color: TBD. SDT-1: Static Dissipative Tile, Armstrong 12"x12" Static Dissipative, Color: TBD.

39. What are the finishes for Supply 9062? And there is not a room on the drawings labeled as such. Should this actually be Supply 9067?

-Supply 9067 on A203 is actually Supply 9062. Walls to have P-1 paint, VCT-1 flooring, VB-1 wall base, ACT-1 ceiling.

40. Still in need for specs for the glazing. The amendment notes indicate they will be issued “in the next drawings issuance”. Does that mean more drawings will be issued and when will that be coming?

-Additional glazing information will be provided in the next submission, but that submission will most likely take place after an award has already been made. At this point, no additional drawings will be issued. The CMc must provide pricing based on the currently issued 65% Construction Drawings.

41. Keynotes #11 & #13 refer to fire rating codes or smoke walls for separation of areas. How are we to determine what is required because the drawings were designed?

-A/E to provide fire and smoke wall requirements for separation of areas in the next submission.

42. Keynotes #14, #15, #16 & #17 indicate weights of equipment to be installed. Keynote #15 states that we are to notify the Tenant for re-design if load exceeds design capacity. Has a building structural engineer been consulted or will be consulted to determine if any of these areas will need structural steel support on the floor below? How are we to determine what is needed?

-The AE will verify the floor loading information in the 100% CD's. The high density storage room 9058 will most likely require some type of additional floor bracing.

43. Keynote #40 calls for wall protection panels (WP-1). What material is this to be?

-42"H Kal-Lite FRP 0.090 textured, Color: TBD.

44. Could you please tell us what would be the correct North direction label on the drawings?

There seems to be a discrepancy between drawings A204 & A205 and also along with the mechanical drawings.

-The correct North direction label points North to the top of the sheet.

45. Due to the holidays and in climate weather, several subcontractors could not attend the 12/30/15. Furthermore, once the Environmental Report is issued, the abatement/demolition contractors will want to come back out to inspect the areas that need to be abated. Can more walkthroughs be scheduled prior to the 1/14/15 bid date? If so when?

-No, at this time no additional walk-through is scheduled. Please contact the property manager listed in the Request for Proposal to request a walk-through. Please note, there is no guarantee that the property manager will accommodate a third walk-through.

46. Compared to the previously issued 100% Design Development drawings, there were many changes / clarifications made on the 65% Construction drawings issued with Addendum #2. The changes made were not highlighted resulting in timely side by side comparisons or completely new takeoffs. Does GSA anticipate further document revisions? Can all further revisions be highlighted / bubbled so that any changes can be fully incorporated into our estimates?

-All contractors should provide pricing/proposal on January 14, 2016, per the 65% Construction Drawings. As updated drawings are issued by the Architect, the selected CMc will work alongside the GSA, the Architect and all other team members and will be responsible for updating their estimate. Highlighting or bubbling is not a requirement for the Architect.

47. Specification Section 262933 relates to Fire Pump Controllers. This equipment is not indicated in the drawings. We request clarification related to this matter.

-There is no fire pump.

48. Specification Section 265116 1.2-B-1 & 2 indicates to reference section 260923 “Lighting Control Devices. Sction 260943.16 “Addressable-Fixture Lighting Controls” and section

260943.2 “Relay-Based Lighting Controls”. These section do not exist in the project documents.

Please clarify this matter.

-Refer to answer from earlier question

49. Clarify if LED or Fluorescent lighting fixtures are desired to be installed on this project.

-LED, per the light fixture schedule.

50. We were searching the project solicitation (specifically the bottom cover page language & p.22 -IV.H.), and were wondering what the Woman owed/DBE requirements are for this project?

-That requirement is for large businesses. Every large business needs to provide a subcontracting plan, however, since this is a total small business set aside, that requirement is not applicable to this procurement.

51. At Public Reception 9003, what is indicated on the Southwest wall? Is that to be millwork of some kind?

-It is an 18" wide writing counter with a solid surface countertop, edge, 6"H backsplash and 6"H wall base. Between the countertop and base is a furred-out p-lam panel with an angled panel beneath the writing counter.

52. SOW p 39.3.6.21, 2nd bullet – Emergency Generator Load Test; Please clarify requirements of the CMc and load testing the generator.

-Not required.

53. Are there any areas on either the 8th or 10th floor that may be sensitive to any noise, dust, vibration, etc. that needs to be taken into consideration?

-"10th floor - Instruments in rooms 1005, 1005A, 1007 and 1008-1012, and 1041 will be affected by vibrations when in operation. High Impact and ""significant"" vibration or noise must be avoided during business hours."

54. Please clarify if a designated area, in the loading dock area, will be provided to stage a dumpster for the duration of the project or if it will need to be relocated each day.

-Yes, a designated area in the loading dock area will be provided for staging a dumpster.

In addition , dumpsters can be switched out at night from the loading dock.

55. Knowing that the freight elevator will not be exclusive to the work on the 9th floor and being that it is slow moving, can a passenger elevator be designated for use during construction in order to facilitate the movement of workers and material?

-The project team will confirm with property management, however, at this time there is no passenger elevator which will be dedicated to this project.

56. Will demolition and associated removal be permitted during the night -Yes, demolition and associated removal will be permitted during the night.

57. Amendment No. 2 contains conflicting statements regarding the fire alarm system. Please confirm that the fire alarm system is under a separate contract and the cost is not to be part of our proposal.

-The installation of a new fire alarm system is not part of this project. That Fire Alarm System will be under a separate contract.

58. Verify that the Fire Alarm system is to be provided by others under separate contract as indicated on sheets E206 & E207.

-Please see above answer to question #57.

59. Solicitation II.E.3, Do all subcontractors and the Prime Contractor’s accounting systems have to be certified and utilize GAAP or just the Prime Contractor?

-Just the prime contractor.

60. Is there an allowance to be used for the decorative frosted film for the glass panels at Meeting #9019?

-The drawings indicate that manufacturer and style of film TBD. You may utilize an allowance to determine your pricing.

61. Specification Section 262923 relates to Variable Frequency Drive Motor Controllers. This equipment is typically provided with the HVAC equipment. Confirm that all VFD’s. motor controllers, motor starters, and disconnects are to be provided with the HVAC equipment.

-Yes, they are to be provided with the HVAC Eq.

62. Submittal Requirements Please clarify the number of original and hard copies to be submitted for BOTH the Technical Proposal and the Price Proposal. There are conflicting statements regarding the submittal requirements: Page 6 of The Solicitation states: Submit one

(1) original and five (5) copies of both the technical and price proposals at the same time. Please mark the original as “Original.” Page 6 of The Solicitation then states directly afterward: The proposal package shall be comprised of two sealed envelopes, one to contain one original and seven copies of the technical proposal to be marked “TECHNICAL PROPOSAL” and the other to contain one original and five copies of the price proposal to be marked “PRICE PROPOSAL”.

All envelopes shall clearly identify the firms’ name and address. Page 8 of the CMc Statement of Work states: Your proposal is due by 01-14-2016 at 1 pm CST to Oana Sandru. One electronic copy of the proposal shall be sent via email to: Oana.sandru@gsa.gov. Should your proposal exceed the file size limitations for email attachments, a CD or flash drive may be sent to the issuing office address. PLEASE INDICATE THE PROPER SUBMITTAL REQUIREMENTS

FOR THIS PROPOSAL.

-Please see question #4. The requirement is for the submittal of one original and five copies of both the technical and the price proposal. The technical and price proposal must be in separate envelopes, each labeled accordingly. No electronic copy of the proposal shall be provided, it would exceed the size standards and would not go through the Government email system.

ASBESTOS LABORATORY REPORT

Prepared for

Carnow, Conibear & Assoc., Ltd.

TEL: 866-481-1412

www.ceilabs.com

PROJECT:

CEI LAB CODE:

DATE ANALYZED:

DATE REPORTED:

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

Post Office Expansion; A153310011-02

A14-15599

11/06/14

11/10/14

Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY

PROJECT: Post Office Expansion; A153310011-02 CEI LAB CODE: A14-15599

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

A1859739 White,Off-white Fireproofing None DetectedDL110514-1

A1859740 White,Off-white Fireproofing None DetectedDL110514-2

A1859741 White Fireproofing None DetectedDL110514-3

A1859742 Gray Plaster None DetectedDL110514-4

A1859743 Gray Plaster None DetectedDL110514-5

A1859744 Gray Plaster None DetectedDL110514-6

A1859745 Gray Floor Tile None DetectedDL110514-7

A1859746 Gray Floor Tile None DetectedDL110514-8

A1859747 Gray Floor Tile None DetectedDL110514-9

A1859748 Beige Mastic None DetectedDL110514-10

A1859749 Beige Mastic None DetectedDL110514-11

A1859750 Beige Mastic None DetectedDL110514-12

A1859751 Brown Sheet Flooring None DetectedDL110514-13

A1859752 Brown Sheet Flooring None DetectedDL110514-14

A1859753 Brown Sheet Flooring None DetectedDL110514-15

A1859754 White Mastic None DetectedDL110514-16

A1859755 Black Mastic None DetectedDL110514-17

A1859756 Black Mastic None DetectedDL110514-18

A1859757 White Insulation None DetectedDL110514-19

A1859758 White Insulation None DetectedDL110514-20

Layer 1 A1859759 White Plaster Skim Coat None DetectedDL110514-21

Layer 2 A1859759 Gray Plaster Base Coat None Detected

Layer 1 A1859760 White Plaster Skim Coat None DetectedDL110514-22

Layer 2 A1859760 Gray Plaster Base Coat None Detected

Layer 1 A1859761 White Plaster Skim Coat None DetectedDL110514-23

Layer 2 A1859761 Gray Plaster Base Coat None Detected

A1859762 Black Postal Tile None DetectedDL110514-24

A1859763 Black Postal Tile None DetectedDL110514-25

A1859764 Black Postal Tile None DetectedDL110514-26

A1859765 Black Mastic None DetectedDL110514-27

A1859766 Black Mastic None DetectedDL110514-28

PROJECT: Post Office Expansion; A153310011-02 CEI LAB CODE: A14-15599

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

A1859767 Black Mastic None DetectedDL110514-29

A1859768 White Duct Wrap None DetectedDL110514-30

A1859769 White Duct Wrap None DetectedDL110514-31

A1859770 White Duct Wrap None DetectedDL110514-32

A1859771 White Fitting Insulation None DetectedDL110514-33

A1859772 White Fitting Insulation None DetectedDL110514-34

A1859773 White Fitting Insulation None DetectedDL110514-35

A1859774 White Cementitious Insulation None DetectedDL110514-36

A1859775 White Cementitious Insulation None DetectedDL110514-37

A1859776 White Cementitious Insulation None DetectedDL110514-38

A1859777 White Heat Exchange Insulation None DetectedDL110514-39

A1859778 White Heat Exchange Insulation None DetectedDL110514-40

A1859779 White Heat Exchange Insulation None DetectedDL110514-41

A1859780 White Tank Insulation ChrysotileDL110514-42 10%

A1859781 White Tank Insulation ChrysotileDL110514-43 10%

A1859782 White Tank Insulation ChrysotileDL110514-44 10%

A1859783 Black Postal Tile None DetectedDL110514-45

A1859784 Black Postal Tile None DetectedDL110514-46

A1859785 Black Postal Tile None DetectedDL110514-47

A1859786 Black Mastic None DetectedDL110514-48

A1859787 Black Mastic None DetectedDL110514-49

A1859788 Black Mastic None DetectedDL110514-50

A1859789 Green Carpet Glue None DetectedDL110514-51

A1859790 Green Carpet Glue None DetectedDL110514-52

A1859791 Green Carpet Glue None DetectedDL110514-53

A1859792 Green Floor Tile ChrysotileDL110514-54 2%

A1859793 Green Floor Tile ChrysotileDL110514-55 2%

A1859794 Green Floor Tile ChrysotileDL110514-56 2%

A1859795 Black Mastic None DetectedDL110514-57

A1859796 Black Mastic None DetectedDL110514-58

A1859797 Black Mastic None DetectedDL110514-59

PROJECT: Post Office Expansion; A153310011-02 CEI LAB CODE: A14-15599

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

A1859798 White Ceiling Tile None DetectedDL110514-60

A1859799 White Ceiling Tile None DetectedDL110514-61

A1859800 White Ceiling Tile None DetectedDL110514-62

A1859801 Brown Adhesive None DetectedDL110514-63

A1859802 Brown Adhesive None DetectedDL110514-64

A1859803 Brown Adhesive None DetectedDL110514-65

A1859804 Yellow Baseboard Adhesive None DetectedDL110514-66

A1859805 Yellow Baseboard Adhesive None DetectedDL110514-67

A1859806 Yellow Baseboard Adhesive None DetectedDL110514-68

A1859807 White Ceiling Tile None DetectedDL110514-69

A1859808 White Ceiling Tile None DetectedDL110514-70

A1859809 White Ceiling Tile None DetectedDL110514-71

Layer 1 A1859810 White Plaster Skim Coat None DetectedDL110514-72

Layer 2 A1859810 Gray Plaster Base Coat None Detected

Layer 1 A1859811 White Plaster Skim Coat None DetectedDL110514-73

Layer 2 A1859811 Gray Plaster Base Coat None Detected

Layer 1 A1859812 White Plaster Skim Coat None DetectedDL110514-74

Layer 2 A1859812 Gray Plaster Base Coat None Detected

A1859813 Brown Sheet Flooring None DetectedDL110514-75

A1859814 Brown Sheet Flooring None DetectedDL110514-76

A1859815 Brown Sheet Flooring None DetectedDL110514-77

A1859816 Black Mastic None DetectedDL110514-78

A1859817 Black Mastic None DetectedDL110514-79

A1859818 Black Mastic None DetectedDL110514-80

A1859819 Red Duct Sealant ChrysotileDL110514-81 2%

A1859820 Red Duct Sealant ChrysotileDL110514-82 2%

A1859821 Red Duct Sealant ChrysotileDL110514-83 2%

ASBESTOS BULK ANALYSIS

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

White,Off-white FireproofingDL110514-1

A1859739 10%Heterogeneous

Fibrous Bound

65% 25%

Fiberglass Binder Vermiculite

None Detected

White,Off-white FireproofingDL110514-2

A1859740 10% 15%

Heterogeneous

Fibrous Bound

55% 20%

Fiberglass Cellulose

Binder Silicates

None Detected

White FireproofingDL110514-3

A1859741 20%Heterogeneous

Fibrous Bound

50% 25% 5%

Cellulose Binder Vermiculite Paint

None Detected

Gray PlasterDL110514-4

A1859742 Heterogeneous

Non-fibrous Tightly Bound

40% 60%

Binder Silicates

None Detected

Gray PlasterDL110514-5

A1859743 Heterogeneous

Non-fibrous Tightly Bound

40% 60%

Binder Silicates

None Detected

Gray PlasterDL110514-6

A1859744 Heterogeneous

Non-fibrous Tightly Bound

40% 60%

Binder Silicates

None Detected

Gray Floor TileDL110514-7

A1859745 Heterogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

Gray Floor TileDL110514-8

A1859746 Heterogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Gray Floor TileDL110514-9

A1859747 Heterogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Beige MasticDL110514-10

A1859748 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Beige MasticDL110514-11

A1859749 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Beige MasticDL110514-12

A1859750 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Brown Sheet FlooringDL110514-13

A1859751 5%Heterogeneous

Fibrous Bound

35% 60%

Cellulose Binder Cork

None Detected

Brown Sheet FlooringDL110514-14

A1859752 5%Heterogeneous

Fibrous Bound

35% 60%

Cellulose Binder Cork

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

Brown Sheet FlooringDL110514-15

A1859753 5%Heterogeneous

Fibrous Bound

35% 60%

Cellulose Binder Cork

None Detected

White MasticDL110514-16

A1859754 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Black MasticDL110514-17

A1859755 10%Heterogeneous

Fibrous Bound

90%Cellulose Mastic None Detected

Black MasticDL110514-18

A1859756 10%Heterogeneous

Fibrous Bound

90%Cellulose Mastic None Detected

White InsulationDL110514-19

A1859757 20%Heterogeneous

Fibrous Loosely Bound

80%Fiberglass Binder None Detected

White InsulationDL110514-20

A1859758 20%Heterogeneous

Fibrous Loosely Bound

80%Fiberglass Binder None Detected

White

DL110514-21

A1859759

Heterogeneous

Non-fibrous Bound

5% 55% 40%

Paint Binder Calc Carb

None Detected Layer 1

Plaster Skim Coat

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

Gray Plaster Base Coat

A1859759 Heterogeneous

Non-fibrous Bound

60% 40%

Binder Silicates

None DetectedLayer 2

White

DL110514-22

A1859760

Heterogeneous

Non-fibrous Bound

5% 55% 40%

Paint Binder Calc Carb

None Detected Layer 1

Plaster Skim Coat

Gray Plaster Base Coat

A1859760 Heterogeneous

Non-fibrous Bound

60% 40%

Binder Silicates

None DetectedLayer 2

White

DL110514-23

A1859761

Heterogeneous

Non-fibrous Bound

5% 55% 40%

Paint Binder Calc Carb

None Detected Layer 1

Plaster Skim Coat

Gray Plaster Base Coat

A1859761 Heterogeneous

Non-fibrous Bound

60% 40%

Binder Silicates

None DetectedLayer 2

Black Postal TileDL110514-24

A1859762 25%Heterogeneous

Fibrous Bound

60% 15%

Cellulose Tar Silicates

None Detected

Black Postal TileDL110514-25

A1859763 25%Heterogeneous

Fibrous Bound

60% 15%

Cellulose Tar Silicates

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

Black Postal TileDL110514-26

A1859764 25%Heterogeneous

Fibrous Bound

60% 15%

Cellulose Tar Silicates

None Detected

Black MasticDL110514-27

A1859765 3%Heterogeneous

Fibrous Bound

97%Cellulose Mastic None Detected

Black MasticDL110514-28

A1859766 3%Heterogeneous

Fibrous Bound

97%Cellulose Mastic None Detected

Black MasticDL110514-29

A1859767 3%Heterogeneous

Fibrous Bound

97%Cellulose Mastic None Detected

White Duct WrapDL110514-30

A1859768 80%Heterogeneous

Fibrous Bound

5% 15%

Cellulose Paint Binder

None Detected

White Duct WrapDL110514-31

A1859769 80%Heterogeneous

Fibrous Bound

5% 15%

Cellulose Paint Binder

None Detected

White Duct WrapDL110514-32

A1859770 80%Heterogeneous

Fibrous Bound

5% 15%

Cellulose Paint Binder

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

White Fitting InsulationDL110514-33

A1859771 15%Heterogeneous

Fibrous Bound

85%Fiberglass Binder None Detected

White Fitting InsulationDL110514-34

A1859772 15%Heterogeneous

Fibrous Bound

85%Fiberglass Binder None Detected

White Fitting InsulationDL110514-35

A1859773 15%Heterogeneous

Fibrous Bound

85%Fiberglass Binder None Detected

White Cementitious InsulationDL110514-36

A1859774 10%Heterogeneous

Fibrous Bound

80% 10%

Fiberglass Binder Silicates

None Detected

White Cementitious InsulationDL110514-37

A1859775 10%Heterogeneous

Fibrous Bound

80% 10%

Fiberglass Binder Silicates

None Detected

White Cementitious InsulationDL110514-38

A1859776 10%Heterogeneous

Fibrous Bound

80% 10%

Fiberglass Binder Silicates

None Detected

White Heat Exchange Insulation

DL110514-39

A1859777

15%Heterogeneous

Fibrous Bound

75% 10%

Fiberglass Binder Silicates

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

White Heat Exchange Insulation

DL110514-40

A1859778

15%Heterogeneous

Fibrous Bound

75% 10%

Fiberglass Binder Silicates

None Detected

White Heat Exchange Insulation

DL110514-41

A1859779

15%Heterogeneous

Fibrous Bound

75% 10%

Fiberglass Binder Silicates

None Detected

White Tank InsulationDL110514-42

A1859780 Heterogeneous

Fibrous Bound

65% 25%

Binder Calc Carb

10% Chrysotile

White Tank InsulationDL110514-43

A1859781 Heterogeneous

Fibrous Bound

65% 25%

Binder Calc Carb

10% Chrysotile

White Tank InsulationDL110514-44

A1859782 Heterogeneous

Fibrous Bound

65% 25%

Binder Calc Carb

10% Chrysotile

Black Postal TileDL110514-45

A1859783 25%Heterogeneous

Fibrous Bound

60% 15%

Cellulose Tar Silicates

None Detected

Black Postal TileDL110514-46

A1859784 25%Heterogeneous

Fibrous Bound

60% 15%

Cellulose Tar Silicates

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

Black Postal TileDL110514-47

A1859785 25%Heterogeneous

Fibrous Bound

60% 15%

Cellulose Tar Silicates

None Detected

Black MasticDL110514-48

A1859786 3%Heterogeneous

Fibrous Bound

97%Cellulose Mastic None Detected

Black MasticDL110514-49

A1859787 3%Heterogeneous

Fibrous Bound

97%Cellulose Mastic None Detected

Black MasticDL110514-50

A1859788 3%Heterogeneous

Fibrous Bound

97%Cellulose Mastic None Detected

Green Carpet GlueDL110514-51

A1859789 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Green Carpet GlueDL110514-52

A1859790 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Green Carpet GlueDL110514-53

A1859791 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

Green Floor TileDL110514-54

A1859792 Heterogeneous

Non-fibrous Bound

78% 20%

Vinyl Calc Carb

2% Chrysotile

Green Floor TileDL110514-55

A1859793 Heterogeneous

Non-fibrous Bound

78% 20%

Vinyl Calc Carb

2% Chrysotile

Green Floor TileDL110514-56

A1859794 Heterogeneous

Non-fibrous Bound

78% 20%

Vinyl Calc Carb

2% Chrysotile

Black MasticDL110514-57

A1859795 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Black MasticDL110514-58

A1859796 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Black MasticDL110514-59

A1859797 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

White Ceiling TileDL110514-60

A1859798 65% 15%

Heterogeneous

Fibrous Bound

5% 15%

Fiberglass Cellulose

Paint Binder

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

White Ceiling TileDL110514-61

A1859799 65% 15%

Heterogeneous

Fibrous Bound

5% 15%

Fiberglass Cellulose

Paint Binder

None Detected

White Ceiling TileDL110514-62

A1859800 65% 15%

Heterogeneous

Fibrous Bound

5% 15%

Fiberglass Cellulose

Paint Binder

None Detected

Brown AdhesiveDL110514-63

A1859801 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Brown AdhesiveDL110514-64

A1859802 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Brown AdhesiveDL110514-65

A1859803 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Yellow Baseboard AdhesiveDL110514-66

A1859804 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Yellow Baseboard AdhesiveDL110514-67

A1859805 Heterogeneous

Non-fibrous Bound

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

Yellow Baseboard AdhesiveDL110514-68

A1859806 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

White Ceiling TileDL110514-69

A1859807 80%Heterogeneous

Fibrous Loosely Bound

5% 15%

Fiberglass Paint Binder

None Detected

White Ceiling TileDL110514-70

A1859808 80%Heterogeneous

Fibrous Loosely Bound

5% 15%

Fiberglass Paint Binder

None Detected

White Ceiling TileDL110514-71

A1859809 80%Heterogeneous

Fibrous Loosely Bound

5% 15%

Fiberglass Paint Binder

None Detected

White

DL110514-72

A1859810

Heterogeneous

Non-fibrous Bound

5% 60% 35%

Paint Binder Calc Carb

None Detected Layer 1

Plaster Skim Coat

Gray Plaster Base Coat

A1859810 Heterogeneous

Non-fibrous Bound

60% 40%

Binder Silicates

None DetectedLayer 2

White

DL110514-73

A1859811

Heterogeneous

Non-fibrous Bound

5% 60% 35%

Paint Binder Calc Carb

None Detected Layer 1

Plaster Skim Coat

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

Gray Plaster Base Coat

A1859811 Heterogeneous

Non-fibrous Bound

60% 40%

Binder Silicates

None DetectedLayer 2

White

DL110514-74

A1859812

Heterogeneous

Non-fibrous Bound

5% 60% 35%

Paint Binder Calc Carb

None Detected Layer 1

Plaster Skim Coat

Gray Plaster Base Coat

A1859812 Heterogeneous

Non-fibrous Bound

60% 40%

Binder Silicates

None DetectedLayer 2

Brown Sheet FlooringDL110514-75

A1859813 5%Heterogeneous

Fibrous Bound

35% 60%

Cellulose Binder Cork

None Detected

Brown Sheet FlooringDL110514-76

A1859814 5%Heterogeneous

Fibrous Bound

35% 60%

Cellulose Binder Cork

None Detected

Brown Sheet FlooringDL110514-77

A1859815 5%Heterogeneous

Fibrous Bound

35% 60%

Cellulose Binder Cork

None Detected

Black MasticDL110514-78

A1859816 Heterogeneous

Non-fibrous Bound

CEI Lab Code: A14-15599 Date Received: 11-06-14 Date Analyzed: 11-06-14 Date Reported: 11-10-14

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Carnow, Conibear & Assoc., Ltd.

600 W Van Buren St Ste 500 Chicago, IL 60607

Project: Post Office Expansion; A153310011-02

Fibrous

Black MasticDL110514-79

A1859817 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Black MasticDL110514-80

A1859818 Heterogeneous

Non-fibrous Bound

100% Mastic None Detected

Red Duct SealantDL110514-81

A1859819 Heterogeneous

Fibrous Bound

98% Caulk 2% Chrysotile

Red Duct SealantDL110514-82

A1859820 Heterogeneous

Fibrous Bound

98% Caulk 2% Chrysotile

Red Duct SealantDL110514-83

A1859821 Heterogeneous

Fibrous Bound

98% Caulk 2% Chrysotile

LEGEND: Non-Anth = Non-Asbestiform Anthophylite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate

The detection limit for the method is <1% by visual estimation and 0.25% by 400 point counts or 0.1% by 1,000 point counts.

Due to the limitations of the EPA 600 Method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarizing light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation.

CEI Labs, Inc. can perform positive stop analysis if requested by customer. However, it is the responsibility of the customer to determine if the samples grouped together are in fact the same type of material and belong to the same homogeneous area.

This report may not be reproduced, except in full, without written approval by CEI LABS. CEI LABS makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U. S. Government.

ANALYST: APPROVED BY:

Tianbao Bai, Ph.D.

Laboratory Director

Greg Ruff

CEI Labs, 107 New Edition Court, Cary, NC 27511, Phone: (866) 481-1412

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

By: TRANSMISSION ELECTRON MICROSCOPY

CEI Lab Code: T14-2453 Date Received: 11-14-14 Date Analyzed: 11-17-14 Date Reported: 11-17-14

Client ID Lab ID

Material Description

TEM BULK CHATFIELD / EPA 600 / R93 / 116

Client: Carnow, Conibear & Assoc., Ltd.

6…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .