Rudman_Equipment_Inventory_RFP.xls
XLS spreadsheet 998 KB Posted
- Attached to
- Maintenance and Repair Services at J. C. Cleveland and W. B. Rudman Federal Office Buildings, Concord, NH
- Solicitation number
- GS-01P-13-BW-D-0008
About this file
W.B. Rudman Equipment List
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FormSF30.pdf | ||
| Q A_3.pdf | ||
| Q A_2.pdf | ||
| FormSF30.pdf | ||
| Q A_1.pdf | ||
| FormSF30.pdf | ||
| Preproposal_Minutes_3.12.2013.pdf | ||
| TAB_10-_RFP_Posted_Correct.pdf | ||
| TAB_10-_RFP_Posted_Correct.pdf | ||
| Pre-proposal_Conference_and_Site_Visit_Posting 1 .pdf | ||
| Cleveland_Equipment_Inventory_RFP.xlsx | XLSX spreadsheet | |
| RFP_Post.pdf | ||
| RFP_2nd_LEVEL_REV.pdf | ||
| Synopsis.pdf | ||
| Pre-proposal_Conference_and_Site_Visit_Posting.doc | DOC document | |
| EQ_List_CLEV.doc | DOC document | |
| EQ_List_RUD.doc | DOC document |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PIVOT TABLE
| PM GUIDE NUMBER | EQUIPMENT NUMBER | LOCATION | MANUFACTURER | MODEL / MODEL NUMBER | SERIAL NUMBER | CONDITION | YEAR | REFRIG. | FUEL | SIZE | DESCRIPTION AND REMARKS |
| A-1 | 1 | PENTHOUSE | AIR COMPRESSOR PRODUCTS INC. | ACPRD | 0331-101-9505-352N | FAIR | R-134A | AIR DRYER, REFRIGERATED | |||
| A-10 | 1 | GUARD SHACK | GENERAL ELECTRIC | AJES12DCMB1 | LH289120 | HEAT PUMP |
HEATIING AND COOLING SERVICE
A-11 1 PENTHOUSE YORK AP400FSAF30 CFDM008149 GOOD 19,940 CFM AIR HANDLER
(AHU-1)
10 PENTHOUSE YORK AP150FSAFII16 CFDM008150 GOOD 7,030 CFM AIR HANDLER
(AHU-10)
11 PENTHOUSE YORK AP250FSAF22 CFDM008151 GOOD 11,520 CFM AIR HANDLER
(AHU-11)
12 PENTHOUSE YORK AP250FSAF22 CFDM008152 GOOD 11,800 CFM AIR HANDLER
(AHU-12)
13 PENTHOUSE YORK AP305FSAF24 CFDM008153 GOOD 13,895 CFM AIR HANDLER
(AHU-13)
14 GARAGE YORK AP400FSFC27X25 CFDM008162 GOOD 25,000 CFM AIR HANDLER
(HV-1)
15 GARAGE YORK AP400FSFC27X25 CFDM008163 GOOD 25,000 CFM AIR HANDLER
(HV-2)
2 PENTHOUSE YORK AP215FSAFII20 CFDM008154 GOOD 10,310 CFM AIR HANDLER
(AHU-2)
3 PENTHOUSE YORK AP305FSAF24 CFDM008155 GOOD 12,580 CFM AIR HANDLER
(AHU-3)
4 PENTHOUSE YORK AP215FSAFII20 CFDM008156 GOOD 8,720 CFM AIR HANDLER
(AHU-4)
5 PENTHOUSE YORK AP305FSAFII24 CFDM008157 GOOD 14,430 CFM AIR HANDLER
(AHU-5)
6 PENTHOUSE YORK AP150FSAFII16 CFDM008158 GOOD 7,045 CFM AIR HANDLER
(AHU-6)
7 PENTHOUSE YORK AP120FSAFII15 CFDM008159 GOOD 5,730 CFM AIR HANDLER
(AHU-7)
8 PENTHOUSE YORK AP170FSAFII18 CFDM008160 GOOD 7,610 CFM AIR HANDLER
(AHU-8)
9 PENTHOUSE YORK AP170SFAFII18 CFDM008161 GOOD 7,470 CFM AIR HANDLER
(AHU-9)
A-12 1 ROOF LIEBERT DSF 109Z 95070218 GOOD 4 TON GLYCOL DRY COOLER
SERVING: A-5-1
2 ROOF LIEBERT DNT 109A 0424C70899 GOOD 4 TON GLYCOL DRY COOLER
SERVING: A-5-2
A-3 1 PENTHOUSE NORTEC SYSTEMS INC. MNHMC ELEC. HUMIDIFICATION SYSTEM
H-1, FOR AHU-13
A-4 1 PENTHOUSE AIR COMPRESSOR PRODUCTS INC. ACPGS02 A5032025 FAIR AIR COMPRESSOR
SERVING: PNEUMATICS FOR VALVES ON AIR HANDLER PUMP PACKAGES
2 PENTHOUSE AIR COMPRESSOR PRODUCTS INC. ACPGS02 A5032027 FAIR AIR COMPRESSOR
SERVING: PNEUMATICS FOR VALVES ON AIR HANDLER PUMP PACKAGES
A-5 1 ROOM 1315 LIEBERT BU071WGASM 322551-001 FAIR R-22 4 TON AIR CONDITIONING MACHINE
SPLIT SYSTEM
(A-12-1) OLD
2 ROOM 1315 LIEBERT BK061G-AAE1 336870-101 GOOD R-22 5 TON AIR CONDITIONING MACHINE
SPLIT SYSTEM
(A-12-2) NEW
| 3 | ROOM 105 | |||||
| AV STORAGE | CARRIER | 40QNB-012300 | 1204Y31611 | GOOD | R-22 | 1 TON |
11,600BTU
208/230V AIR CONDITIONING MACHINE
SPLIT SYSTEM
A-7 1 MARSHALL CONTROL ROOM MOVINCOOL CLASSIC PLUS 14 EXCELLENT R-410a 10,000 BTU AIR CONDITIONING MACHINE
PACKAGE UNIT, SPECIAL PURPOSE
COOLING ONLY
A-9 1 GARAGE CEILING CARRIER 38AN-012320 1404Y20890 GOOD R-22 1 TON
1.7LB R-22
.032KW
1/44HP AIR-COOLED CONDENSER
SERVING (A-5-3)
C-2 1 PENTHOUSE GENERATOR ROOM 24 X 24 IN REMOTE AIR INTAKE DAMPERS,
MOTORIZED
INTAKE AIR FOR GENERATOR ROOM
2 PENTHOUSE GENERATOR ROOM 54 X 72 IN REMOTE AIR INTAKE DAMPERS,
MOTORIZED
INTAKE AIR FOR GENERATOR ROOM
3 PENTHOUSE GENERATOR ROOM 60 X 72 IN REMOTE AIR INTAKE DAMPERS,
MOTORIZED
EXHAUST AIR FOR GENERATOR ROOM
4 PENTHOUSE GENERATOR ROOM 18 X 72 IN REMOTE AIR INTAKE DAMPERS,
MOTORIZED
MIXED AIR FOR GENERATOR ROOM
| 5 | PENTHOUSE ROOF | |||
| WEST SIDE | 50 X 50 IN | REMOTE AIR INTAKE DAMPERS, |
MOTORIZED
EXHAUST FOR SMOKE EVAC. SYSTEM
(EF-7)
6 PENTHOUSE EAST SIDE 36 X 48 IN REMOTE AIR INTAKE DAMPERS,
MOTORIZED
INTAKE AIR FOR PENTHOUSE
7 PENTHOUSE SOUTH SIDE 48 X 48 IN REMOTE AIR INTAKE DAMPERS,
MOTORIZED
EXHAUST AIR FOR PENTHOUSE
| C-3 | 1 | FIRST FLOOR ROOM 1404 | 1.22 SQ FT | COILS, REHEAT TB-101 | |||||
| 10 | FIRST FLOOR ROOM 1100 | 0.69 SQ FT | COILS, REHEAT TB-110 | ||||||
| 100 | SECOND FLOOR | ||||||||
| WAITING 2110 | 1.22 SQ FT | COILS, REHEAT TB-249 | |||||||
| 101 | SECOND FLOOR | ||||||||
| ROOM 2109 | 1.67 SQ FT | COILS, REHEAT TB-250 | |||||||
| 102 | SECOND FLOOR | ||||||||
| ROOM 2108 | 1.67 SQ FT | COILS, REHEAT TB-251 | |||||||
| 103 | SECOND FLOOR | ||||||||
| ROOM 2103 | 2.92 SQ FT | COILS, REHEAT TB-252 | |||||||
| 104 | SECOND FLOOR | ||||||||
| ROOM 2103 | 1.22 SQ FT | COILS, REHEAT TB-253 | |||||||
| 105 | SECOND FLOOR | ||||||||
| ROOM 2105 | 2.92 SQ FT | COILS, REHEAT TB-254 | |||||||
| 106 | SECOND FLOOR | ||||||||
| ROOM 2105 | 2.43 SQ FT | COILS, REHEAT TB-255 | |||||||
| 107 | SECOND FLOOR | ||||||||
| ROOM 2101 | 0.83 SQ FT | COILS, REHEAT TB-256 | |||||||
| 108 | SECOND FLOOR | ||||||||
| ROOM 2327 | 0.69 SQ FT | COILS, REHEAT TB-257 | |||||||
| 109 | SECOND FLOOR | ||||||||
| CORRIDOR 2625 | 0.56 SQ FT | COILS, REHEAT TB-258 | |||||||
| 11 | FIRST FLOOR | ||||||||
| VESTIBULE 1103 | 0.69 SQ FT | COILS, REHEAT TB-111 | |||||||
| 110 | THIRD FLOOR | ||||||||
| CORRIDOR 3406 | 1.22 SQ FT | COILS, REHEAT TB-301 | |||||||
| 111 | THIRD FLOOR | ||||||||
| CORRIDOR 3405 | 0.69 SQ FT | COILS, REHEAT TB-302 | |||||||
| 112 | THIRD FLOOR | ||||||||
| CORRIDOR 3501 | 2.92 SQ FT | COILS, REHEAT TB-303 | |||||||
| 113 | THIRD FLOOR | ||||||||
| ROOM 3416 | 0.69 SQ FT | COILS, REHEAT TB-304 | |||||||
| 114 | THIRD FLOOR | ||||||||
| CORRIDOR 3419 | 0.69 SQ FT | COILS, REHEAT TB-305 | |||||||
| 115 | THIRD FLOOR | ||||||||
| CORRIDOR 3419 | 1.22 SQ FT | COILS, REHEAT TB-306 | |||||||
| 116 | THIRD FLOOR | ||||||||
| CORRIDOR 3419 | 0.69 SQ FT | COILS, REHEAT TB-307 | |||||||
| 117 | THIRD FLOOR | ||||||||
| ROOM 3425 | 2.43 SQ FT | COILS, REHEAT TB-308 | |||||||
| 118 | THIRD FLOOR | ||||||||
| ROOM 3426 | 2.43 SQ FT | COILS, REHEAT TB-309 | |||||||
| 119 | THIRD FLOOR | ||||||||
| ROOM 3425 | 0.83 SQ FT | COILS, REHEAT TB-310 | |||||||
| 12 | FIRST FLOOR | ||||||||
| VESTIBULE 1103 | 0.69 SQ FT | COILS, REHEAT TB-112 | |||||||
| 120 | THIRD FLOOR | ||||||||
| ROOM 3425 | 0.83 SQ FT | COILS, REHEAT TB-311 | |||||||
| 121 | THIRD FLOOR | ||||||||
| ROOM 3303 | 1.67 SQ FT | COILS, REHEAT TB-312 | |||||||
| 122 | THIRD FLOOR | ||||||||
| ROOM 3301 | 0.69 SQ FT | COILS, REHEAT TB-313 | |||||||
| 123 | THIRD FLOOR | ||||||||
| ROOM 3301 | 0.69 SQ FT | COILS, REHEAT TB-314 | |||||||
| 124 | THIRD FLOOR | ||||||||
| ROOM 3301 | 2.92 SQ FT | COILS, REHEAT TB-315 | |||||||
| 125 | THIRD FLOOR | ||||||||
| ROOM 3304 | 1.67 SQ FT | COILS, REHEAT TB-316 | |||||||
| 126 | THIRD FLOOR | ||||||||
| ROOM 3303 | 2.92 SQ FT | COILS, REHEAT TB-317 | |||||||
| 127 | THIRD FLOOR | ||||||||
| ROOM 3311 | 1.67 SQ FT | COILS, REHEAT TB-318 | |||||||
| 128 | THIRD FLOOR | ||||||||
| ROOM 3318 | 0.69 SQ FT | COILS, REHEAT TB-319 | |||||||
| 129 | THIRD FLOOR | ||||||||
| ROOM 3319 | 1.22 SQ FT | COILS, REHEAT TB-320 | |||||||
| 13 | FIRST FLOOR ROOM 1109 | 0.69 SQ FT | COILS, REHEAT TB-113 | ||||||
| 130 | THIRD FLOOR | ||||||||
| ROOM 3705 | 0.83 SQ FT | COILS, REHEAT TB-321 | |||||||
| 131 | THIRD FLOOR | ||||||||
| CORRIDOR 3703 | 2.92 SQ FT | COILS, REHEAT TB-322 | |||||||
| 132 | THIRD FLOOR | ||||||||
| CORRIDOR 3703 | 2.43 SQ FT | COILS, REHEAT TB-323 | |||||||
| 133 | THIRD FLOOR | ||||||||
| ROOM 3705 | 0.69 SQ FT | COILS, REHEAT TB-324 | |||||||
| 134 | THIRD FLOOR | ||||||||
| CORRIDOR 3703 | 2.92 SQ FT | COILS, REHEAT TB-325 | |||||||
| 135 | THIRD FLOOR | ||||||||
| TOILET 3201 | 2.43 SQ FT | COILS, REHEAT TB-326 | |||||||
| 136 | THIRD FLOOR | ||||||||
| ROOM 3204 | 2.43 SQ FT | COILS, REHEAT TB-327 | |||||||
| 137 | THIRD FLOOR | ||||||||
| ROOM 3206 | 0.69 SQ FT | COILS, REHEAT TB-328 | |||||||
| 138 | THIRD FLOOR | ||||||||
| ROOM 3206 | 0.69 SQ FT | COILS, REHEAT TB-329 | |||||||
| 139 | THIRD FLOOR | ||||||||
| ROOM 3123 | 0.83 SQ FT | COILS, REHEAT TB-330 | |||||||
| 14 | FIRST FLOOR CORRIDOR 1106 | 1.22 SQ FT | COILS, REHEAT TB-114 | ||||||
| 140 | THIRD FLOOR | ||||||||
| ROOM 3124 | 0.69 SQ FT | COILS, REHEAT TB-331 | |||||||
| 141 | THIRD FLOOR | ||||||||
| ROOM 3124 | 2.43 SQ FT | COILS, REHEAT TB-332 | |||||||
| 142 | THIRD FLOOR | ||||||||
| ROOM 3124 | 2.43 SQ FT | COILS, REHEAT TB-333 | |||||||
| 143 | THIRD FLOOR | ||||||||
| ROOM 3125 | 0.69 SQ FT | COILS, REHEAT TB-334 | |||||||
| 144 | THIRD FLOOR | ||||||||
| ROOM 3125 | 0.69 SQ FT | COILS, REHEAT TB-335 | |||||||
| 145 | THIRD FLOOR | ||||||||
| ROOM 3125 | 0.69 SQ FT | COILS, REHEAT TB-336 | |||||||
| 146 | THIRD FLOOR | ||||||||
| VESTIBULE 3103 | 2.92 SQ FT | COILS, REHEAT TB-337 | |||||||
| 147 | THIRD FLOOR | ||||||||
| VESTIBULE 3103 | 0.69 SQ FT | COILS, REHEAT TB-338 | |||||||
| 148 | THIRD FLOOR | ||||||||
| ROOM 3109 | 0.69 SQ FT | COILS, REHEAT TB-339 | |||||||
| 149 | THIRD FLOOR | ||||||||
| ROOM 3104 | 1.22 SQ FT | COILS, REHEAT TB-340 | |||||||
| 15 | FIRST FLOOR ROOM 1115 | 0.69 SQ FT | COILS, REHEAT TB-115 | ||||||
| 150 | THIRD FLOOR | ||||||||
| ROOM 3213 | 0.83 SQ FT | COILS, REHEAT TB-341 | |||||||
| 151 | THIRD FLOOR | ||||||||
| ROOM 3320 | 0.69 SQ FT | COILS, REHEAT TB-342 | |||||||
| 152 | THIRD FLOOR | ||||||||
| CORRIDOR 3215 | 1.22 SQ FT | COILS, REHEAT TB-343 | |||||||
| 153 | THIRD FLOOR | ||||||||
| ROOM 3206 | 2.92 SQ FT | COILS, REHEAT TB-344 | |||||||
| 154 | FOURTH FLOOR | ||||||||
| ROOM 4503 | 0.69 SQ FT | COILS, REHEAT TB-401 | |||||||
| 155 | FOURTH FLOOR | ||||||||
| ROOM 4504 | 0.83 SQ FT | COILS, REHEAT TB-402 | |||||||
| 156 | FOURTH FLOOR | ||||||||
| ROOM 4506 | 1.22 SQ FT | COILS, REHEAT TB-403 | |||||||
| 157 | FOURTH FLOOR | ||||||||
| ROOM 4506 | 1.22 SQ FT | COILS, REHEAT TB-404 | |||||||
| 158 | FOURTH FLOOR | ||||||||
| ROOM 4508 | 1.22 SQ FT | COILS, REHEAT TB-405 | |||||||
| 159 | FOURTH FLOOR | ||||||||
| ROOM 4516 | 0.69 SQ FT | COILS, REHEAT TB-406 | |||||||
| 16 | FIRST FLOOR ROOM 1115 | 0.69 SQ FT | COILS, REHEAT TB-116 | ||||||
| 160 | FOURTH FLOOR | ||||||||
| ROOM 4514 | 0.83 SQ FT | COILS, REHEAT TB-407 | |||||||
| 161 | FOURTH FLOOR | ||||||||
| ROOM 4520 | 1.22 SQ FT | COILS, REHEAT TB-408 | |||||||
| 162 | FOURTH FLOOR | ||||||||
| ROOM 4523 | 0.69 SQ FT | COILS, REHEAT TB-409 | |||||||
| 163 | FOURTH FLOOR | ||||||||
| ROOM 4524 | 0.69 SQ FT | COILS, REHEAT TB-410 | |||||||
| 164 | FOURTH FLOOR | ||||||||
| CORRIDOR 4526 | 1.22 SQ FT | COILS, REHEAT TB-411 | |||||||
| 165 | FOURTH FLOOR | ||||||||
| ROOM 4401 | 2.92 SQ FT | COILS, REHEAT TB-412 | |||||||
| 166 | FOURTH FLOOR | ||||||||
| ROOM 4405 | 0.69 SQ FT | COILS, REHEAT TB-413 | |||||||
| 167 | FOURTH FLOOR | ||||||||
| ROOM 4402 | 0.69 SQ FT | COILS, REHEAT TB-414 | |||||||
| 168 | FOURTH FLOOR | ||||||||
| ROOM 4407 | 0.83 SQ FT | COILS, REHEAT TB-415 | |||||||
| 169 | FOURTH FLOOR | ||||||||
| ROOM 4403 | 1.22 SQ FT | COILS, REHEAT TB-416 | |||||||
| 17 | FIRST FLOOR ROOM 1104 | 0.83 SQ FT | COILS, REHEAT TB-117 | ||||||
| 170 | FOURTH FLOOR | ||||||||
| ROOM 4412 | 0.69 SQ FT | COILS, REHEAT TB-417 | |||||||
| 171 | FOURTH FLOOR | ||||||||
| ROOM 4417 | 0.69 SQ FT | COILS, REHEAT TB-418 | |||||||
| 172 | FOURTH FLOOR | ||||||||
| ROOM 4424 | 0.69 SQ FT | COILS, REHEAT TB-419 | |||||||
| 173 | FOURTH FLOOR | ||||||||
| ROOM 4425 | 0.69 SQ FT | COILS, REHEAT TB-420 | |||||||
| 174 | FOURTH FLOOR | ||||||||
| ROOM 4426 | 0.69 SQ FT | COILS, REHEAT TB-421 | |||||||
| 175 | FOURTH FLOOR | ||||||||
| ROOM 4419 | 0.83 SQ FT | COILS, REHEAT TB-422 | |||||||
| 176 | FOURTH FLOOR | ||||||||
| ROOM 4428 | 1.22 SQ FT | COILS, REHEAT TB-423 | |||||||
| 177 | FOURTH FLOOR | ||||||||
| ROOM 4423 | 0.69 SQ FT | COILS, REHEAT TB-424 | |||||||
| 178 | FOURTH FLOOR | ||||||||
| ROOM 4320 | 0.69 SQ FT | COILS, REHEAT TB-425 | |||||||
| 179 | FOURTH FLOOR | ||||||||
| ROOM 4321 | 0.69 SQ FT | COILS, REHEAT TB-426 | |||||||
| 18 | FIRST FLOOR ROOM 1513 | 1.22 SQ FT | COILS, REHEAT TB-118 | ||||||
| 180 | FOURTH FLOOR | ||||||||
| ROOM 4322 | 0.69 SQ FT | COILS, REHEAT TB-427 | |||||||
| 181 | FOURTH FLOOR | ||||||||
| ROOM 4324 | 0.83 SQ FT | COILS, REHEAT TB-428 | |||||||
| 182 | FOURTH FLOOR | ||||||||
| ROOM 4326 | 0.69 SQ FT | COILS, REHEAT TB-429 | |||||||
| 183 | FOURTH FLOOR | ||||||||
| ROOM 4329 | 1.22 SQ FT | COILS, REHEAT TB-430 | |||||||
| 184 | FOURTH FLOOR | ||||||||
| ROOM 4618 | 3.65 SQ FT | COILS, REHEAT TB-431 | |||||||
| 185 | FOURTH FLOOR | ||||||||
| ROOM 4618 | 2.43 SQ FT | COILS, REHEAT TB-432 | |||||||
| 186 | FOURTH FLOOR | ||||||||
| ROOM 4618 | 2.92 SQ FT | COILS, REHEAT TB-433 | |||||||
| 187 | FOURTH FLOOR | ||||||||
| ROOM 4613 | 0.69 SQ FT | COILS, REHEAT TB-434 | |||||||
| 188 | FOURTH FLOOR | ||||||||
| ROOM 4613 | 2.43 SQ FT | COILS, REHEAT TB-435 | |||||||
| 189 | FOURTH FLOOR | ||||||||
| CORRIDOR 4315 | 0.69 SQ FT | COILS, REHEAT TB-436 | |||||||
| 19 | FIRST FLOOR ROOM 1122 | 1.22 SQ FT | COILS, REHEAT TB-119 | ||||||
| 190 | FOURTH FLOOR | ||||||||
| ROOM 4602 | 0.69 SQ FT | COILS, REHEAT TB-437 | |||||||
| 191 | FOURTH FLOOR | ||||||||
| ROOM 4306 | 1.22 SQ FT | COILS, REHEAT TB-438 | |||||||
| 192 | FOURTH FLOOR | ||||||||
| ROOM 4306 | 1.22 SQ FT | COILS, REHEAT TB-439 | |||||||
| 193 | FOURTH FLOOR | ||||||||
| ROOM 4306 | 1.22 SQ FT | COILS, REHEAT TB-440 | |||||||
| 194 | FOURTH FLOOR | ||||||||
| ROOM 4603 | 0.83 SQ FT | COILS, REHEAT TB-441 | |||||||
| 195 | FOURTH FLOOR | ||||||||
| ROOM 4307 | 0.69 SQ FT | COILS, REHEAT TB-442 | |||||||
| 196 | FOURTH FLOOR | ||||||||
| ROOM 4310 | 0.69 SQ FT | COILS, REHEAT TB-443 | |||||||
| 197 | FOURTH FLOOR | ||||||||
| CORRIDOR 4315 | 1.22 SQ FT | COILS, REHEAT TB-444 | |||||||
| 198 | FOURTH FLOOR | ||||||||
| ROOM 4112 | 0.69 SQ FT | COILS, REHEAT TB-445 | |||||||
| 199 | FOURTH FLOOR | ||||||||
| ROOM 4113 | 1.00 SQ FT | COILS, REHEAT TB-446 | |||||||
| 2 | FIRST FLOOR | ||||||||
| CORRIDOR 1412 | 0.69 SQ FT | COILS, REHEAT TB-102 | |||||||
| 20 | FIRST FLOOR ROOM 1121 | 0.69 SQ FT | COILS, REHEAT TB-120 | ||||||
| 200 | FOURTH FLOOR | ||||||||
| ROOM 4110 | 1.22 SQ FT | COILS, REHEAT TB-447 | |||||||
| 201 | FOURTH FLOOR | ||||||||
| ROOM 4110 | 1.22 SQ FT | COILS, REHEAT TB-448 | |||||||
| 202 | FOURTH FLOOR | ||||||||
| ROOM 4104 | 0.69 SQ FT | COILS, REHEAT TB-449 | |||||||
| 203 | FOURTH FLOOR | ||||||||
| ROOM 4117 | 1.22 SQ FT | COILS, REHEAT TB-450 | |||||||
| 204 | FOURTH FLOOR | ||||||||
| ROOM 4122 | 0.69 SQ FT | COILS, REHEAT TB-451 | |||||||
| 205 | FOURTH FLOOR | ||||||||
| ROOM 4114 | 1.22 SQ FT | COILS, REHEAT TB-452 | |||||||
| 206 | FOURTH FLOOR | ||||||||
| CORRIDOR 4201 | 0.83 SQ FT | COILS, REHEAT TB-453 | |||||||
| 207 | FOURTH FLOOR | ||||||||
| CORRIDOR 4201 | 0.69 SQ FT | COILS, REHEAT TB-454 | |||||||
| 208 | FOURTH FLOOR | ||||||||
| ROOM 4126 | 1.22 SQ FT | COILS, REHEAT TB-455 | |||||||
| 209 | FOURTH FLOOR | ||||||||
| ROOM 4207 | 1.22 SQ FT | COILS, REHEAT TB-456 | |||||||
| 21 | FIRST FLOOR ROOM 1122 | 0.69 SQ FT | COILS, REHEAT TB-121 | ||||||
| 210 | FOURTH FLOOR | ||||||||
| ROOM 4210 | 0.83 SQ FT | COILS, REHEAT TB-457 | |||||||
| 211 | FOURTH FLOOR | ||||||||
| ROOM 4213 | 1.22 SQ FT | COILS, REHEAT TB-458 | |||||||
| 212 | FOURTH FLOOR | ||||||||
| ROOM 4211 | 0.69 SQ FT | COILS, REHEAT TB-459 | |||||||
| 213 | FOURTH FLOOR | ||||||||
| ROOM 4217 | 1.22 SQ FT | COILS, REHEAT TB-460 | |||||||
| 214 | FOURTH FLOOR | ||||||||
| ROOM 4212 | 0.69 SQ FT | COILS, REHEAT TB-461 | |||||||
| 215 | FOURTH FLOOR | ||||||||
| ROOM 4218 | 0.83 SQ FT | COILS, REHEAT TB-462 | |||||||
| 216 | FOURTH FLOOR | ||||||||
| ROOM 4227 | 0.69 SQ FT | COILS, REHEAT TB-463 | |||||||
| 217 | FOURTH FLOOR | ||||||||
| ROOM 4230 | 1.22 SQ FT | COILS, REHEAT TB-464 | |||||||
| 218 | FOURTH FLOOR | ||||||||
| ROOM 4219 | 1.22 SQ FT | COILS, REHEAT TB-465 | |||||||
| 219 | FOURTH FLOOR | ||||||||
| ROOM 4232 | 1.22 SQ FT | COILS, REHEAT TB-466 | |||||||
| 22 | FIRST FLOOR ROOM 1124 | 0.69 SQ FT | COILS, REHEAT TB-122 | ||||||
| 220 | FOURTH FLOOR | ||||||||
| ROOM 4232 | 0.69 SQ FT | COILS, REHEAT TB-467 | |||||||
| 23 | FIRST FLOOR ROOM 1301 | 1.67 SQ FT | COILS, REHEAT TB-123 | ||||||
| 24 | FIRST FLOOR ROOM 13014 | 0.69 SQ FT | COILS, REHEAT TB-124 | ||||||
| 25 | FIRST FLOOR ANTE ROOM 1301 | 0.69 SQ FT | COILS, REHEAT TB-125 | ||||||
| 26 | FIRST FLOOR CORRIDOR 1302 | 0.69 SQ FT | COILS, REHEAT TB-126 | ||||||
| 27 | FIRST FLOOR CORRIDOR 1302 | 1.67 SQ FT | COILS, REHEAT TB-127 | ||||||
| 28 | FIRST FLOOR ROOM 1318 | 0.69 SQ FT | COILS, REHEAT TB-128 | ||||||
| 29 | FIRST FLOOR ROOM 1316 | 1.67 SQ FT | COILS, REHEAT TB-129 | ||||||
| 3 | FIRST FLOOR ROOM 1414 | 1.22 SQ FT | COILS, REHEAT TB-103 | ||||||
| 30 | FIRST FLOOR ROOM 1320 | 1.22 SQ FT | COILS, REHEAT TB-130 | ||||||
| 31 | FIRST FLOOR CORRIDOR 1314 | 1.22 SQ FT | COILS, REHEAT TB-131 | ||||||
| 32 | FIRST FLOOR ROOM 1313 | 1.22 SQ FT | COILS, REHEAT TB-132 | ||||||
| 33 | FIRST FLOOR ROOM 1322 | 0.69 SQ FT | COILS, REHEAT TB-133 | ||||||
| 34 | FIRST FLOOR ROOM 1324 | 0.69 SQ FT | COILS, REHEAT TB-134 | ||||||
| 35 | FIRST FLOOR ROOM 1325 | 0.69 SQ FT | COILS, REHEAT TB-135 | ||||||
| 36 | FIRST FLOOR ROOM 1326 | 0.69 SQ FT | COILS, REHEAT TB-136 | ||||||
| 37 | FIRST FLOOR ROOM 1329 | 2.43 SQ FT | COILS, REHEAT TB-137 | ||||||
| 38 | FIRST FLOOR CORRIDOR 1330 | 0.69 SQ FT | COILS, REHEAT TB-138 | ||||||
| 39 | FIRST FLOOR ROOM 1711 | 0.69 SQ FT | COILS, REHEAT TB-139 | ||||||
| 4 | FIRST FLOOR ROOM 1414 | 1.67 SQ FT | COILS, REHEAT TB-104 | ||||||
| 40 | FIRST FLOOR ROOM 1712 | 0.69 SQ FT | COILS, REHEAT TB-140 | ||||||
| 41 | FIRST FLOOR ROOM 1709 | 1.67 SQ FT | COILS, REHEAT TB-141 | ||||||
| 42 | FIRST FLOOR ROOM 1707 | 0.69 SQ FT | COILS, REHEAT TB-142 | ||||||
| 43 | FIRST FLOOR ROOM 1706 | 0.69 SQ FT | COILS, REHEAT TB-143 | ||||||
| 44 | FIRST FLOOR ROOM 1209 | 2.43 SQ FT | COILS, REHEAT TB-144 | ||||||
| 45 | FIRST FLOOR ROOM 1209 | 2.43 SQ FT | COILS, REHEAT TB-145 | ||||||
| 46 | FIRST FLOOR ROOM 1212 | 0.69 SQ FT | COILS, REHEAT TB-146 | ||||||
| 47 | FIRST FLOOR ROOM 1210 | 2.43 SQ FT | COILS, REHEAT TB-147 | ||||||
| 48 | FIRST FLOOR ROOM 1205 | 1.67 SQ FT | COILS, REHEAT TB-148 | ||||||
| 49 | FIRST FLOOR ROOM 1204 | 1.22 SQ FT | COILS, REHEAT TB-149 | ||||||
| 5 | FIRST FLOOR ROOM 1414 | 0.69 SQ FT | COILS, REHEAT TB-105 | ||||||
| 50 | FIRST FLOOR ROOM 1206 | 0.69 SQ FT | COILS, REHEAT TB-150 | ||||||
| 51 | FIRST FLOOR ROOM 1705 | 1.67 SQ FT | COILS, REHEAT TB-151 | ||||||
| 52 | SECOND FLOOR ROOM 2407 | 1.22 SQ FT | COILS, REHEAT TB-201 | ||||||
| 53 | SECOND FLOOR ROOM 2404 | 0.83 SQ FT | COILS, REHEAT TB-202 | ||||||
| 54 | SECOND FLOOR ROOM 2407 | 0.69 SQ FT | COILS, REHEAT TB-203 | ||||||
| 55 | SECOND FLOOR VESTIBULE 2414 | 0.69 SQ FT | COILS, REHEAT TB-204 | ||||||
| 56 | SECOND FLOOR CORRIDOR 2417 | 1.67 SQ FT | COILS, REHEAT TB-205 | ||||||
| 57 | SECOND FLOOR ROOM 2422 | 2.92 SQ FT | COILS, REHEAT TB-206 | ||||||
| 58 | SECOND FLOOR ROOM 2422 | 2.92 SQ FT | COILS, REHEAT TB-207 | ||||||
| 59 | SECOND FLOOR ROOM 2422 | 2.43 SQ FT | COILS, REHEAT TB-208 | ||||||
| 6 | FIRST FLOOR ROOM 1424 | 1.22 SQ FT | COILS, REHEAT TB-106 | ||||||
| 60 | SECOND FLOOR ROOM 2422 | 0.69 SQ FT | COILS, REHEAT TB-209 | ||||||
| 61 | SECOND FLOOR ROOM 2422 | 1.22 SQ FT | COILS, REHEAT TB-210 | ||||||
| 62 | SECOND FLOOR ROOM 2422 | 1.67 SQ FT | COILS, REHEAT TB-211 | ||||||
| 63 | SECOND FLOOR ROOM 2424 | 0.69 SQ FT | COILS, REHEAT TB-212 | ||||||
| 64 | SECOND FLOOR | 0.69 SQ FT | COILS, REHEAT TB-213 | ||||||
| 65 | SECOND FLOOR | ||||||||
| ROOM 2426 | 0.69 SQ FT | COILS, REHEAT TB-214 | |||||||
| 66 | SECOND FLOOR | ||||||||
| ROOM 2429 | 0.69 SQ FT | COILS, REHEAT TB-215 | |||||||
| 67 | SECOND FLOOR | ||||||||
| ROOM 2301 | 0.69 SQ FT | COILS, REHEAT TB-216 | |||||||
| 68 | SECOND FLOOR | ||||||||
| ROOM 2302 | 0.69 SQ FT | COILS, REHEAT TB-217 | |||||||
| 69 | SECOND FLOOR | ||||||||
| ROOM 2305 | 1.22 SQ FT | COILS, REHEAT TB-218 | |||||||
| 7 | FIRST FLOOR ROOM 1425 | 0.69 SQ FT | COILS, REHEAT TB-107 | ||||||
| 70 | SECOND FLOOR | ||||||||
| ROOM 2329 | 0.69 SQ FT | COILS, REHEAT TB-219 | |||||||
| 71 | SECOND FLOOR | ||||||||
| CORRIDOR 2304 | 0.69 SQ FT | COILS, REHEAT TB-220 | |||||||
| 72 | SECOND FLOOR | ||||||||
| ROOM 2307 | 0.69 SQ FT | COILS, REHEAT TB-221 | |||||||
| 73 | SECOND FLOOR | ||||||||
| ROOM 2309 | 0.69 SQ FT | COILS, REHEAT TB-222 | |||||||
| 74 | SECOND FLOOR | ||||||||
| ROOM 2310 | 0.69 SQ FT | COILS, REHEAT TB-223 | |||||||
| 75 | SECOND FLOOR | ||||||||
| ROOM 2311 | 0.69 SQ FT | COILS, REHEAT TB-224 | |||||||
| 76 | SECOND FLOOR | ||||||||
| ROOM 2316 | 0.69 SQ FT | COILS, REHEAT TB-225 | |||||||
| 77 | SECOND FLOOR | ||||||||
| ROOM 2318 | 1.22 SQ FT | COILS, REHEAT TB-226 | |||||||
| 78 | SECOND FLOOR | ||||||||
| ROOM 2313 | 0.83 SQ FT | COILS, REHEAT TB-227 | |||||||
| 79 | SECOND FLOOR | ||||||||
| ROOM 2623 | 1.67 SQ FT | COILS, REHEAT TB-228 | |||||||
| 8 | FIRST FLOOR ROOM 1424 | 0.69 SQ FT | COILS, REHEAT TB-108 | ||||||
| 80 | SECOND FLOOR | ||||||||
| ROOM 2626 | 2.43 SQ FT | COILS, REHEAT TB-229 | |||||||
| 81 | SECOND FLOOR | ||||||||
| ROOM 2626 | 2.43 SQ FT | COILS, REHEAT TB-230 | |||||||
| 82 | SECOND FLOOR | ||||||||
| ROOM 2623 | 1.67 SQ FT | COILS, REHEAT TB-231 | |||||||
| 83 | SECOND FLOOR | ||||||||
| ROOM 2219 | 0.69 SQ FT | COILS, REHEAT TB-232 | |||||||
| 84 | SECOND FLOOR | ||||||||
| ROOM 2217 | 0.69 SQ FT | COILS, REHEAT TB-233 | |||||||
| 85 | SECOND FLOOR | ||||||||
| ROOM 2216 | 0.69 SQ FT | COILS, REHEAT TB-234 | |||||||
| 86 | SECOND FLOOR | ||||||||
| ROOM 2212 | 2.43 SQ FT | COILS, REHEAT TB-235 | |||||||
| 87 | SECOND FLOOR | ||||||||
| TOILET 2208 | 0.69 SQ FT | COILS, REHEAT TB-236 | |||||||
| 88 | SECOND FLOOR | ||||||||
| ROOM 2211 | 0.69 SQ FT | COILS, REHEAT TB-237 | |||||||
| 89 | SECOND FLOOR | ||||||||
| ROOM 2212 | 0.83 SQ FT | COILS, REHEAT TB-238 | |||||||
| 9 | FIRST FLOOR ROOM 1427 | 0.69 SQ FT | COILS, REHEAT TB-109 | ||||||
| 90 | SECOND FLOOR | ||||||||
| ROOM 2227 | 1.22 SQ FT | COILS, REHEAT TB-239 | |||||||
| 91 | SECOND FLOOR | ||||||||
| ROOM 2227 | 0.69 SQ FT | COILS, REHEAT TB-240 | |||||||
| 92 | SECOND FLOOR | ||||||||
| ROOM 2203 | 1.22 SQ FT | COILS, REHEAT TB-241 | |||||||
| 93 | SECOND FLOOR | ||||||||
| VAULT 2617 | 1.22 SQ FT | COILS, REHEAT TB-242 | |||||||
| 94 | SECOND FLOOR | ||||||||
| ROOM 2116 | 0.69 SQ FT | COILS, REHEAT TB-243 | |||||||
| 95 | SECOND FLOOR | ||||||||
| ROOM 2119 | 1.22 SQ FT | COILS, REHEAT TB-244 | |||||||
| 96 | SECOND FLOOR | ||||||||
| CORRIDOR 2618 | 1.22 SQ FT | COILS, REHEAT TB-245 | |||||||
| 97 | SECOND FLOOR | ||||||||
| CORRIDOR 2618 | 1.67 SQ FT | COILS, REHEAT TB-246 | |||||||
| 98 | SECOND FLOOR | ||||||||
| ROOM 2111 | 1.67 SQ FT | COILS, REHEAT TB-247 | |||||||
| 99 | SECOND FLOOR | ||||||||
| CORRIDOR 2112 | 0.69 SQ FT | COILS, REHEAT TB-248 | |||||||
| C-4 | (blank) | VARIOUS LOCATIONS AS LISTED | JOHNSON CONTROL | METASYS CONTROL SYSTEM | CENTRAL MINI COMPUTER, HVAC |
DC-4-101 / DC-4-168 CONTROLLERS:
68 (VAV BOXES FLOOR 4)
DC-3-101 / DC-3-144 CONTROLLERS:
44 (VAV BOXES FLOOR 3)
DC-2-101 / DC-4-158 CONTROLLERS:
58 (VAV BOXES FLOOR 2)
DC-2-159 / DC-2-161 CONTROLLERS:
3 (SMOKE DAMPERS FOR FL
1 MECHANICAL OFFICE JOHNSON CONTROL METASYS CONTROL SYSTEM CENTRAL MINI COMPUTER, HVAC
EMS COMPUTER:
DELL MOD: DHM
SER: 5K8D941
PRINTER:
CANON MOD: PIXMA IP4200
MONITOR:
COMPAQ MOD: S700
DX CONTROLLERS: 7 FCU, 2 H&V, 2 HX IN GARAGE
2 PENTHOUSE WORK STATION JOHNSON CONTROL METASYS CONTROL SYSTEM CENTRAL MINI COMPUTER, HVAC
ISN YORK TALK XL:1
PART#: 371-02085-001
EMS COMPUTER:
DELL MOD: DHM
SER: 5K8D941
PRINTER:
CANON MOD: PIXMA IP4200
MONITOR:
DELL MOD: M782
DX CONTROLLERS: 13 AHU, 2 HX, 1 CHILLER
| C-5 | 1 | FIRST FLOOR ROOM 1404 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-101 | |||
| 10 | FIRST FLOOR ROOM 1100 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-110 | ||||
| 100 | SECOND FLOOR | ||||||
| WAITING 2110 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-249 | |||||
| 101 | SECOND FLOOR | ||||||
| ROOM 2109 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-250 | |||||
| 102 | SECOND FLOOR | ||||||
| ROOM 2108 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-251 | |||||
| 103 | SECOND FLOOR | ||||||
| ROOM 2103 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-252 | |||||
| 104 | SECOND FLOOR | ||||||
| ROOM 2103 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-253 | |||||
| 105 | SECOND FLOOR | ||||||
| ROOM 2105 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-254 | |||||
| 106 | SECOND FLOOR | ||||||
| ROOM 2105 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-255 | |||||
| 107 | SECOND FLOOR | ||||||
| ROOM 2101 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-256 | |||||
| 108 | SECOND FLOOR | ||||||
| ROOM 2327 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-257 | |||||
| 109 | SECOND FLOOR | ||||||
| CORRIDOR 2625 | DUCT SIZE: 10 X 8 | AUTOMATIC MIXING BOX, ELECTRIC TB-258 | |||||
| 11 | FIRST FLOOR | ||||||
| VESTIBULE 1103 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-111 | |||||
| 110 | THIRD FLOOR | ||||||
| CORRIDOR 3406 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-301 | |||||
| 111 | THIRD FLOOR | ||||||
| CORRIDOR 3405 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-302 | |||||
| 112 | THIRD FLOOR | ||||||
| CORRIDOR 3501 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-303 | |||||
| 113 | THIRD FLOOR | ||||||
| ROOM 3416 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-304 | |||||
| 114 | THIRD FLOOR | ||||||
| CORRIDOR 3419 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-305 | |||||
| 115 | THIRD FLOOR | ||||||
| CORRIDOR 3419 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-306 | |||||
| 116 | THIRD FLOOR | ||||||
| CORRIDOR 3419 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-307 | |||||
| 117 | THIRD FLOOR | ||||||
| ROOM 3425 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-308 | |||||
| 118 | THIRD FLOOR | ||||||
| ROOM 3426 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-309 | |||||
| 119 | THIRD FLOOR | ||||||
| ROOM 3425 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-310 | |||||
| 12 | FIRST FLOOR | ||||||
| VESTIBULE 1103 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-112 | |||||
| 120 | THIRD FLOOR | ||||||
| ROOM 3425 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-311 | |||||
| 121 | THIRD FLOOR | ||||||
| ROOM 3303 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-312 | |||||
| 122 | THIRD FLOOR | ||||||
| ROOM 3301 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-313 | |||||
| 123 | THIRD FLOOR | ||||||
| ROOM 3301 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-314 | |||||
| 124 | THIRD FLOOR | ||||||
| ROOM 3301 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-315 | |||||
| 125 | THIRD FLOOR | ||||||
| ROOM 3304 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-316 | |||||
| 126 | THIRD FLOOR | ||||||
| ROOM 3303 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-317 | |||||
| 127 | THIRD FLOOR | ||||||
| ROOM 3311 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-318 | |||||
| 128 | THIRD FLOOR | ||||||
| ROOM 3318 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-319 | |||||
| 129 | THIRD FLOOR | ||||||
| ROOM 3319 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-320 | |||||
| 13 | FIRST FLOOR ROOM 1109 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-113 | ||||
| 130 | THIRD FLOOR | ||||||
| ROOM 3705 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-321 | |||||
| 131 | THIRD FLOOR | ||||||
| CORRIDOR 3703 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-322 | |||||
| 132 | THIRD FLOOR | ||||||
| CORRIDOR 3703 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-323 | |||||
| 133 | THIRD FLOOR | ||||||
| ROOM 3705 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-324 | |||||
| 134 | THIRD FLOOR | ||||||
| CORRIDOR 3703 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-325 | |||||
| 135 | THIRD FLOOR | ||||||
| TOILET 3201 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-326 | |||||
| 136 | THIRD FLOOR | ||||||
| ROOM 3204 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-327 | |||||
| 137 | THIRD FLOOR | ||||||
| ROOM 3206 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-328 | |||||
| 138 | THIRD FLOOR | ||||||
| ROOM 3206 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-329 | |||||
| 139 | THIRD FLOOR | ||||||
| ROOM 3123 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-330 | |||||
| 14 | FIRST FLOOR CORRIDOR 1106 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-114 | ||||
| 140 | THIRD FLOOR | ||||||
| ROOM 3124 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-331 | |||||
| 141 | THIRD FLOOR | ||||||
| ROOM 3124 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-332 | |||||
| 142 | THIRD FLOOR | ||||||
| ROOM 3124 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-333 | |||||
| 143 | THIRD FLOOR | ||||||
| ROOM 3125 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-334 | |||||
| 144 | THIRD FLOOR | ||||||
| ROOM 3125 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-335 | |||||
| 145 | THIRD FLOOR | ||||||
| ROOM 3125 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-336 | |||||
| 146 | THIRD FLOOR | ||||||
| VESTIBULE 3103 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-337 | |||||
| 147 | THIRD FLOOR | ||||||
| VESTIBULE 3103 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-338 | |||||
| 148 | THIRD FLOOR | ||||||
| ROOM 3109 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-339 | |||||
| 149 | THIRD FLOOR | ||||||
| ROOM 3104 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-340 | |||||
| 15 | FIRST FLOOR ROOM 1115 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-115 | ||||
| 150 | THIRD FLOOR | ||||||
| ROOM 3213 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-341 | |||||
| 151 | THIRD FLOOR | ||||||
| ROOM 3320 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-342 | |||||
| 152 | THIRD FLOOR | ||||||
| CORRIDOR 3215 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-343 | |||||
| 153 | THIRD FLOOR | ||||||
| ROOM 3206 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-344 | |||||
| 154 | FOURTH FLOOR | ||||||
| ROOM 4503 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-401 | |||||
| 155 | FOURTH FLOOR | ||||||
| ROOM 4504 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-402 | |||||
| 156 | FOURTH FLOOR | ||||||
| ROOM 4506 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-403 | |||||
| 157 | FOURTH FLOOR | ||||||
| ROOM 4506 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-404 | |||||
| 158 | FOURTH FLOOR | ||||||
| ROOM 4508 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-405 | |||||
| 159 | FOURTH FLOOR | ||||||
| ROOM 4516 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-406 | |||||
| 16 | FIRST FLOOR ROOM 1115 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-116 | ||||
| 160 | FOURTH FLOOR | ||||||
| ROOM 4514 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-407 | |||||
| 161 | FOURTH FLOOR | ||||||
| ROOM 4520 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-408 | |||||
| 162 | FOURTH FLOOR | ||||||
| ROOM 4523 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-409 | |||||
| 163 | FOURTH FLOOR | ||||||
| ROOM 4524 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-410 | |||||
| 164 | FOURTH FLOOR | ||||||
| CORRIDOR 4526 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-411 | |||||
| 165 | FOURTH FLOOR | ||||||
| ROOM 4401 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-412 | |||||
| 166 | FOURTH FLOOR | ||||||
| ROOM 4405 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-413 | |||||
| 167 | FOURTH FLOOR | ||||||
| ROOM 4402 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-414 | |||||
| 168 | FOURTH FLOOR | ||||||
| ROOM 4407 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-415 | |||||
| 169 | FOURTH FLOOR | ||||||
| ROOM 4403 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-416 | |||||
| 17 | FIRST FLOOR ROOM 1104 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-117 | ||||
| 170 | FOURTH FLOOR | ||||||
| ROOM 4412 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-417 | |||||
| 171 | FOURTH FLOOR | ||||||
| ROOM 4417 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-418 | |||||
| 172 | FOURTH FLOOR | ||||||
| ROOM 4424 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-419 | |||||
| 173 | FOURTH FLOOR | ||||||
| ROOM 4425 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-420 | |||||
| 174 | FOURTH FLOOR | ||||||
| ROOM 4426 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-421 | |||||
| 175 | FOURTH FLOOR | ||||||
| ROOM 4419 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-422 | |||||
| 176 | FOURTH FLOOR | ||||||
| ROOM 4428 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-423 | |||||
| 177 | FOURTH FLOOR | ||||||
| ROOM 4423 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-424 | |||||
| 178 | FOURTH FLOOR | ||||||
| ROOM 4320 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-425 | |||||
| 179 | FOURTH FLOOR | ||||||
| ROOM 4321 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-426 | |||||
| 18 | FIRST FLOOR ROOM 1513 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-118 | ||||
| 180 | FOURTH FLOOR | ||||||
| ROOM 4322 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-427 | |||||
| 181 | FOURTH FLOOR | ||||||
| ROOM 4324 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-428 | |||||
| 182 | FOURTH FLOOR | ||||||
| ROOM 4326 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-429 | |||||
| 183 | FOURTH FLOOR | ||||||
| ROOM 4329 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-430 | |||||
| 184 | FOURTH FLOOR | ||||||
| ROOM 4618 | DUCT SIZE: 30 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-431 | |||||
| 185 | FOURTH FLOOR | ||||||
| ROOM 4618 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-432 | |||||
| 186 | FOURTH FLOOR | ||||||
| ROOM 4618 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-433 | |||||
| 187 | FOURTH FLOOR | ||||||
| ROOM 4613 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-434 | |||||
| 188 | FOURTH FLOOR | ||||||
| ROOM 4613 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-435 | |||||
| 189 | FOURTH FLOOR | ||||||
| CORRIDOR 4315 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-436 | |||||
| 19 | FIRST FLOOR ROOM 1122 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-119 | ||||
| 190 | FOURTH FLOOR | ||||||
| ROOM 4602 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-437 | |||||
| 191 | FOURTH FLOOR | ||||||
| ROOM 4306 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-438 | |||||
| 192 | FOURTH FLOOR | ||||||
| ROOM 4306 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-439 | |||||
| 193 | FOURTH FLOOR | ||||||
| ROOM 4306 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-440 | |||||
| 194 | FOURTH FLOOR | ||||||
| ROOM 4603 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-441 | |||||
| 195 | FOURTH FLOOR | ||||||
| ROOM 4307 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-442 | |||||
| 196 | FOURTH FLOOR | ||||||
| ROOM 4310 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-443 | |||||
| 197 | FOURTH FLOOR | ||||||
| CORRIDOR 4315 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-444 | |||||
| 198 | FOURTH FLOOR | ||||||
| ROOM 4112 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-445 | |||||
| 199 | FOURTH FLOOR | ||||||
| ROOM 4113 | DUCT SIZE: 12 X 12 | AUTOMATIC MIXING BOX, ELECTRIC TB-446 | |||||
| 2 | FIRST FLOOR | ||||||
| CORRIDOR 1412 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-102 | |||||
| 20 | FIRST FLOOR ROOM 1121 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-120 | ||||
| 200 | FOURTH FLOOR | ||||||
| ROOM 4110 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-447 | |||||
| 201 | FOURTH FLOOR | ||||||
| ROOM 4110 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-448 | |||||
| 202 | FOURTH FLOOR | ||||||
| ROOM 4104 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-449 | |||||
| 203 | FOURTH FLOOR | ||||||
| ROOM 4117 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-450 | |||||
| 204 | FOURTH FLOOR | ||||||
| ROOM 4122 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-451 | |||||
| 205 | FOURTH FLOOR | ||||||
| ROOM 4114 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-452 | |||||
| 206 | FOURTH FLOOR | ||||||
| CORRIDOR 4201 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-453 | |||||
| 207 | FOURTH FLOOR | ||||||
| CORRIDOR 4201 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-454 | |||||
| 208 | FOURTH FLOOR | ||||||
| ROOM 4126 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-455 | |||||
| 209 | FOURTH FLOOR | ||||||
| ROOM 4207 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-456 | |||||
| 21 | FIRST FLOOR ROOM 1122 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-121 | ||||
| 210 | FOURTH FLOOR | ||||||
| ROOM 4210 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-457 | |||||
| 211 | FOURTH FLOOR | ||||||
| ROOM 4213 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-458 | |||||
| 212 | FOURTH FLOOR | ||||||
| ROOM 4211 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-459 | |||||
| 213 | FOURTH FLOOR | ||||||
| ROOM 4217 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-460 | |||||
| 214 | FOURTH FLOOR | ||||||
| ROOM 4212 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-461 | |||||
| 215 | FOURTH FLOOR | ||||||
| ROOM 4218 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-462 | |||||
| 216 | FOURTH FLOOR | ||||||
| ROOM 4227 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-463 | |||||
| 217 | FOURTH FLOOR | ||||||
| ROOM 4230 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-464 | |||||
| 218 | FOURTH FLOOR | ||||||
| ROOM 4219 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-465 | |||||
| 219 | FOURTH FLOOR | ||||||
| ROOM 4232 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-466 | |||||
| 22 | FIRST FLOOR ROOM 1124 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-122 | ||||
| 220 | FOURTH FLOOR | ||||||
| ROOM 4232 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-467 | |||||
| 23 | FIRST FLOOR ROOM 1301 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-123 | ||||
| 24 | FIRST FLOOR ROOM 13014 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-124 | ||||
| 25 | FIRST FLOOR ANTE ROOM 1301 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-125 | ||||
| 26 | FIRST FLOOR CORRIDOR 1302 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-126 | ||||
| 27 | FIRST FLOOR CORRIDOR 1302 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-127 | ||||
| 28 | FIRST FLOOR ROOM 1318 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-128 | ||||
| 29 | FIRST FLOOR ROOM 1316 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-129 | ||||
| 3 | FIRST FLOOR ROOM 1414 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-103 | ||||
| 30 | FIRST FLOOR ROOM 1320 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-130 | ||||
| 31 | FIRST FLOOR CORRIDOR 1314 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-131 | ||||
| 32 | FIRST FLOOR ROOM 1313 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-132 | ||||
| 33 | FIRST FLOOR ROOM 1322 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-133 | ||||
| 34 | FIRST FLOOR ROOM 1324 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-134 | ||||
| 35 | FIRST FLOOR ROOM 1325 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-135 | ||||
| 36 | FIRST FLOOR ROOM 1326 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-136 | ||||
| 37 | FIRST FLOOR ROOM 1329 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-137 | ||||
| 38 | FIRST FLOOR CORRIDOR 1330 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-138 | ||||
| 39 | FIRST FLOOR ROOM 1711 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-139 | ||||
| 4 | FIRST FLOOR ROOM 1414 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-104 | ||||
| 40 | FIRST FLOOR ROOM 1712 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-140 | ||||
| 41 | FIRST FLOOR ROOM 1709 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-141 | ||||
| 42 | FIRST FLOOR ROOM 1707 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-142 | ||||
| 43 | FIRST FLOOR ROOM 1706 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-143 | ||||
| 44 | FIRST FLOOR ROOM 1209 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-144 | ||||
| 45 | FIRST FLOOR ROOM 1209 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-145 | ||||
| 46 | FIRST FLOOR ROOM 1212 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-146 | ||||
| 47 | FIRST FLOOR ROOM 1210 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-147 | ||||
| 48 | FIRST FLOOR ROOM 1205 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-148 | ||||
| 49 | FIRST FLOOR ROOM 1204 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-149 | ||||
| 5 | FIRST FLOOR ROOM 1414 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-105 | ||||
| 50 | FIRST FLOOR ROOM 1206 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-150 | ||||
| 51 | FIRST FLOOR ROOM 1705 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-151 | ||||
| 52 | SECOND FLOOR ROOM 2407 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-201 | ||||
| 53 | SECOND FLOOR ROOM 2404 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-202 | ||||
| 54 | SECOND FLOOR ROOM 2407 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-203 | ||||
| 55 | SECOND FLOOR VESTIBULE 2414 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-204 | ||||
| 56 | SECOND FLOOR CORRIDOR 2417 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-205 | ||||
| 57 | SECOND FLOOR ROOM 2422 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-206 | ||||
| 58 | SECOND FLOOR ROOM 2422 | DUCT SIZE: 24 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-207 | ||||
| 59 | SECOND FLOOR ROOM 2422 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-208 | ||||
| 6 | FIRST FLOOR ROOM 1424 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-106 | ||||
| 60 | SECOND FLOOR ROOM 2422 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-209 | ||||
| 61 | SECOND FLOOR ROOM 2422 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-210 | ||||
| 62 | SECOND FLOOR ROOM 2422 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-211 | ||||
| 63 | SECOND FLOOR ROOM 2424 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-212 | ||||
| 64 | SECOND FLOOR | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-213 | ||||
| 65 | SECOND FLOOR | ||||||
| ROOM 2426 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-214 | |||||
| 66 | SECOND FLOOR | ||||||
| ROOM 2429 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-215 | |||||
| 67 | SECOND FLOOR | ||||||
| ROOM 2301 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-216 | |||||
| 68 | SECOND FLOOR | ||||||
| ROOM 2302 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-217 | |||||
| 69 | SECOND FLOOR | ||||||
| ROOM 2305 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-218 | |||||
| 7 | FIRST FLOOR ROOM 1425 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-107 | ||||
| 70 | SECOND FLOOR | ||||||
| ROOM 2329 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-219 | |||||
| 71 | SECOND FLOOR | ||||||
| CORRIDOR 2304 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-220 | |||||
| 72 | SECOND FLOOR | ||||||
| ROOM 2307 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-221 | |||||
| 73 | SECOND FLOOR | ||||||
| ROOM 2309 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-222 | |||||
| 74 | SECOND FLOOR | ||||||
| ROOM 2310 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-223 | |||||
| 75 | SECOND FLOOR | ||||||
| ROOM 2311 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-224 | |||||
| 76 | SECOND FLOOR | ||||||
| ROOM 2316 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-225 | |||||
| 77 | SECOND FLOOR | ||||||
| ROOM 2318 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-226 | |||||
| 78 | SECOND FLOOR | ||||||
| ROOM 2313 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-227 | |||||
| 79 | SECOND FLOOR | ||||||
| ROOM 2623 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-228 | |||||
| 8 | FIRST FLOOR ROOM 1424 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-108 | ||||
| 80 | SECOND FLOOR | ||||||
| ROOM 2626 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-229 | |||||
| 81 | SECOND FLOOR | ||||||
| ROOM 2626 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-230 | |||||
| 82 | SECOND FLOOR | ||||||
| ROOM 2623 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-231 | |||||
| 83 | SECOND FLOOR | ||||||
| ROOM 2219 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-232 | |||||
| 84 | SECOND FLOOR | ||||||
| ROOM 2217 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-233 | |||||
| 85 | SECOND FLOOR | ||||||
| ROOM 2216 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-234 | |||||
| 86 | SECOND FLOOR | ||||||
| ROOM 2212 | DUCT SIZE: 20 X 17-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-235 | |||||
| 87 | SECOND FLOOR | ||||||
| TOILET 2208 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-236 | |||||
| 88 | SECOND FLOOR | ||||||
| ROOM 2211 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-237 | |||||
| 89 | SECOND FLOOR | ||||||
| ROOM 2212 | DUCT SIZE: 12 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-238 | |||||
| 9 | FIRST FLOOR ROOM 1427 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-109 | ||||
| 90 | SECOND FLOOR | ||||||
| ROOM 2227 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-239 | |||||
| 91 | SECOND FLOOR | ||||||
| ROOM 2227 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-240 | |||||
| 92 | SECOND FLOOR | ||||||
| ROOM 2203 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-241 | |||||
| 93 | SECOND FLOOR | ||||||
| VAULT 2617 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-242 | |||||
| 94 | SECOND FLOOR | ||||||
| ROOM 2116 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-243 | |||||
| 95 | SECOND FLOOR | ||||||
| ROOM 2119 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-244 | |||||
| 96 | SECOND FLOOR | ||||||
| CORRIDOR 2618 | DUCT SIZE: 14 X 12-1/2 | AUTOMATIC MIXING BOX, ELECTRIC TB-245 | |||||
| 97 | SECOND FLOOR | ||||||
| CORRIDOR 2618 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-246 | |||||
| 98 | SECOND FLOOR | ||||||
| ROOM 2111 | DUCT SIZE: 16 X 15 | AUTOMATIC MIXING BOX, ELECTRIC TB-247 | |||||
| 99 | SECOND FLOOR | ||||||
| CORRIDOR 2112 | DUCT SIZE: 10 X 10 | AUTOMATIC MIXING BOX, ELECTRIC TB-248 | |||||
| C-6 | 1-198 | AT AIR HANDLERS | CONTROLS, CENTRAL SYSTEM, HVAC |
TEMPERATURE SENSORS: 52
LOW PRESSURE SWITCHES: 13
HIGH PRESSURE SWITCHES: 26
END SWITCHES: 65
FREEZE STATS: 13
STATIC PRESSURE SENSORS: 13
CARBON DIOXIDE DETECTORS: 14
HUMIDISTATS (AHU-13 ONLY): 1
199-215 GARAGE H&V UNITS CONTROLS, CENTRAL SYSTEM, HVAC
TEMPERATURE SENSORS: 4
HIGH PRESSURE SWITCHES: 3
END SWITCHES: 4
FREEZE STATS: 2
CO MONITOR: 4
216-434 AT VAV BOXES CONTROLS, CENTRAL SYSTEM, HVAC
SPACE THERMOSTATS: 219
435-441 AT FAN COIL UNITS CONTROLS, CENTRAL SYSTEM, HVAC
SPACE THERMOSTATS: 7
442-449 FOR FIN TUBE RADIATION AND CONVECTORS CONTROLS, CENTRAL SYSTEM, HVAC
SPACE THERMOSTATS: 8
450-454 FOR CABINET AND UNIT HEATERS CONTROLS, CENTRAL SYSTEM, HVAC
SPACE THERMOSTATS: 5
455 MECHANICAL ROOM VENTILATION CONTROLS, CENTRAL SYSTEM, HVAC
SPACE THERMOSTATS: 1
456-470 IN AHU SYSTEMS CONTROLS, CENTRAL SYSTEM, HVAC
OCCUPANCY POINTS: 15
471-475 RETURN AND HW HEATING SYSTEM CONTROLS, CENTRAL SYSTEM, HVAC
RETURN FLOW TRANSMITTER: 1
SUPPLY FLOW TRANSMITTER: 1
TEMPERATURE SENSOR: 3
476-479 CONDENSATE HEAT RECOVERY SYSTEM CONTROLS, CENTRAL SYSTEM, HVAC
PH MONITOR: 1
TEMPERATURE SENSORS: 3
480-481 CHILLED WATER & CONDENSOR WATER PIPING CONTROLS, CENTRAL SYSTEM, HVAC
FLOW CONTROL DEVICES: 2
482-488 SNOW MELTING SYSTEM IN DRIVEWAY CONTROLS, CENTRAL SYSTEM, HVAC
SERVICE SWITCH: 1
SNOW / ICE DETECTOR: 2
SLAB SENSOR: 2
SUPPLY SENSOR: 1
RETURN SENSOR: 1
489-490 SNOW MELTING SYSTEM IN FRONT STAIRS CONTROLS, CENTRAL SYSTEM, HVAC
SERVICE SWITCH: 1
SUPPLY SENSOR: 1
C-7 1 GARAGE NORTH WALL SHIPCO 603PCD3 12382 2 HP DUAL MOTORS CONDENSATE PUMP
CP-1
2 GARAGE BY STAIR #3 SHIPCO 372PCD3 12383 1 HP DUAL MOTORS CONDENSATE PUMP
CP-2
3 GARAGE BY STAIR #3 ROTH HOFFMAN 254A-42 3/4 HP DUAL MOTORS CONDENSATE PUMP
CP-3
C-9,10 1 ROOF EVAPCO AT8-912B 941722 300 TON COOLING TOWER
CT-1
2 ROOF EVAPCO AT8-912B 941721 300 TON COOLING TOWER
CT-2
D-1 1 GARAGE RYTEC SPIRAL HIGH PERFORMANCE DOORS 80197 DOOR, POWER OPERATED
WITH 460V MOTOR / GEARBOX
2 GARAGE RYTEC SPIRAL HIGH PERFORMANCE DOORS 80196 DOOR, POWER OPERATED
HIGH SPEED OVERHEAD DOOR
WITH 460V MOTOR / GEARBOX
3 SALLEYPORT CORNELL IRONWORKS ACGL-50 12007 1/2 HP MOTOR DOOR, POWER OPERATED
OVERHEAD ROLL-UP (OUT)
4 SALLEYPORT CORNELL IRONWORKS ACGL-50 12008 1/2 HP MOTOR DOOR, POWER OPERATED
OVERHEAD ROLL-UP (IN)
5 LOADING DOCK LIFT-MASTER HTL211 SS486-A6-60595 1/2 HP MOTOR DOOR, POWER OPERATED
OVERHEAD SECTIONAL
6 LOADING DOCK MANARS MTBH 98-143847-7 1/3 HP MOTOR DOOR, POWER OPERATED
OVERHEAD SECTIONAL
| 7 | COURTROOM 3 | SKYLITE | CURTAIN, POWER OPERATED | ||
| D-3 | 11 | MAIN ROOF | 3" | DRAINS, ROOF |
(1)
12-13 LINK ROOF 3" DRAINS, ROOF
(2)
1-7 MAIN ROOF 5" DRAINS, ROOF
(7)
8-10 MAIN ROOF 4" DRAINS, ROOF
(3)
D-4 1-2 MAIN ENTRANCE STANLEY MAGIC DOORS 117V
60HZ
1PH 15A DOORS, AUTOMATIC - ELECTRIC
MAGIC SWING CONCEALED OPERATOR
D-5 1 MAIN ENTRANCE CRANE DOOR, MAIN ENTRANCE
REVOLVING
| 2 | GROUNDS | |||||
| GUARD SHACK | DOOR, MAIN ENTRANCE | |||||
| 3 | WEST STAIRWAY, GROUND FLOOR | DOOR, MAIN ENTRANCE | ||||
| 4 | EAST STAIRWAY, GROUND FLOOR | DOOR, MAIN ENTRANCE | ||||
| 5-6 | LOADING DOCK | DOOR, MAIN ENTRANCE | ||||
| D-6 | 1-16 | PENTHOUSE | 4" | DRAINS, FLOOR | ||
| 17-22 | TERRACE | 4" | DRAINS, DECK | |||
| 23-44 | GARAGE | 4" | DRAINS, FLOOR | |||
| 45-46 | GARAGE | 6" | DRAINS, FLOOR | |||
| 47 | GARAGE | DRAINS, TRENCH | ||||
| 48-49 | OUTSIDE GARAGE DOORS | DRAINS, TRENCH | ||||
| 50-53 | AREAWAYS | 4" | DRAINS, AREAWAY | |||
| 54-55 | GROUNDS WEST SIDE LAWN AREA | DRAINS, STORM | ||||
| E-1-9 | 1 | ELEVATOR SHAFT | 5500LBS | ELEVATOR, HYRDAULIC |
3 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
10 ELEVATOR SHAFT 4000LBS ELEVATOR, HYRDAULIC
3 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
11 ELEVATOR SHAFT 4500LBS ELEVATOR, HYRDAULIC
6 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
2 ELEVATOR SHAFT 4500LBS ELEVATOR, HYRDAULIC
3 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
3 ELEVATOR SHAFT 4000LBS ELEVATOR, HYRDAULIC
3 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
4 ELEVATOR SHAFT 4000LBS ELEVATOR, HYRDAULIC
3 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
5 ELEVATOR SHAFT 3000LBS ELEVATOR, HYRDAULIC
5 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
6 ELEVATOR SHAFT 3000LBS ELEVATOR, HYRDAULIC
4 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
7 ELEVATOR SHAFT 4500LBS ELEVATOR, HYRDAULIC
5 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
8 ELEVATOR SHAFT 4000LBS ELEVATOR, HYRDAULIC
4 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
9 ELEVATOR SHAFT 4000LBS ELEVATOR, HYRDAULIC
3 FLOORS
MANUFACTURER:
CAB: BRYCE SOUTHERN
HYDRAULICS: CANTON ELEVATOR
ELECTRONICS: MOTION CONTROL
| E-26 | 1 | EB-40, MAIN SWITCHBOARD ROOM | CUTLER HAMMER / WESTINGHOUSE | DS 632 | 6616C36G04 | 480 / 277V | |
| 3,200A | LOW VOLTAGE MOLDED |
CASE CIRCUIT BREAKER
CUBICLE # 1
SERVING: MAIN BREAKER
10 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 11
SERVING: ATS #2
11 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 12
SERVING: ATS #3
12 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 13
SERVING: CHILLER #1
13 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 14
SERVING: CHILLER #2
14 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 15
SERVING: SPARE
15 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 16
SERVING: SPARE
2 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 3
SERVING: DH1
3 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 4
SERVING: PANEL DH2
4 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 5
SERVING: PANEL DH3
5 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 6
SERVING: PANEL DH4
6 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 7
SERVING: PANEL PHB
7 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 8
SERVING: PANEL PHM
8 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 9
SERVING: SPARE
9 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE 600A LOW VOLTAGE MOLDED
CASE CIRCUIT BREAKER
CUBICLE # 10
SERVING: ATS #1
E-30 1 EB-40, MAIN SWITCHBOARD ROOM CUTLER HAMMER / WESTINGHOUSE POW-R-LINE HUBS53167 SWITCHBOARDS, MEDIUM VOLTAGE
NO. OF CUBICLES: 19
13 ACTIVE CUBICLES (ONE WITH OWNER METERING)
3 SPARE CUBICLES
3 SPACE AND HARDWARE CUBICLES
E-33 1 EB-40 CUTLER HAMMER / WESTINGHOUSE 956014-A1 HIGH VOLTAGE NETWORK AND POWER DRY TYPE TRANSFORMER.
INSTRUCTION BOOK 43500-054-11
KVA: 2,000
VOLTAGE: 13,800 DELTA/480Y/277
AMPERAGE: 111.6-3208
RATING: 5.51
E-34 1 EB-40 CUTLER HAMMER / WESTINGHOUSE 13,800V DELTA DISCONNECTS, ISOLATING SWITCH.
MAIN SERVICE DISCONNECT
E-34A 10 ROOM B020 CUTLER HAMMER / WESTINGHOUSE 100A DISCONNECTS, ISOLATING SWITCH.
SHUNT TRIP FOR ELEVATOR
11 ROOM B022 CUTLER HAMMER / WESTINGHOUSE 125A DISCONNECTS, ISOLATING SWITCH.
SHUNT TRIP FOR ELEVATOR
1-2 ROOM B017 CUTLER HAMMER / WESTINGHOUSE 125A DISCONNECTS, ISOLATING SWITCH.
SHUNT TRIP FOR ELEVATORS
3 ROOM B006 CUTLER HAMMER / WESTINGHOUSE 125A DISCONNECTS, ISOLATING SWITCH.
SHUNT TRIP FOR ELEVATOR
4 ROOM B005 CUTLER HAMMER / WESTINGHOUSE 125A DISCONNECTS, ISOLATING SWITCH.
SHUNT TRIP FOR ELEVATOR
5-6 ROOM B010 CUTLER HAMMER / WESTINGHOUSE 125A DISCONNECTS, ISOLATING SWITCH.
SHUNT TRIP FOR ELEVATORS
7-9 ROOM B009 CUTLER HAMMER / WESTINGHOUSE 125A DISCONNECTS, ISOLATING SWITCH.
SHUNT TRIP FOR ELEVATORS
E-35 1 PENTHOUSE OUTSIDE ROOM 5105 CUTLER HAMMER / WESTINGHOUSE SERIES 2100 / HUBS53167 MOTOR CONTROL CENTER
600A, 277/480V, 3 PHASE, 4 WIRE
NO. OF MOTOR STARTERS:
5 ACTIVE
1 SPARE
3 SPACE
2 GARAGE, EB-42 CUTLER HAMMER / WESTINGHOUSE SERIES 2100 / HUBS53167 MOTOR CONTROL CENTER
600A, 277/480V, 3 PHASE, 4 WIRE
NO. OF MOTOR STARTERS:
2 ACTIVE
1 SPARE
2 SPACE
E-36 1 5104, EMERGENCY EQUIPMENT ROOM AUTOMATIC SWITCH CO. 962 3 POLE
260A
277/480V AUTOMATIC TRANSFER SWITCH
ATS 1, LIFE SAFETY SERVICE
2 5104, EMERGENCY EQUIPMENT ROOM AUTOMATIC SWITCH CO. 448 3 POLE
800A
480V AUTOMATIC TRANSFER SWITCH
ATS 2, SERVING PANEL EDH
3 EB-41 AUTOMATIC SWITCH CO. 448 4 POLE
800A
277/480V AUTOMATIC TRANSFER SWITCH
ATS 2, SERVING ELEVATORS
| E-37 | 1-3 | 5105 | CUTLER HAMMER / WESTINGHOUSE | 1200A | |
| 277/480V | BUS DUCT, LOW VOLTAGE AND CONNECTORS |
COPPER TYPE
DISCONNECTS: 0
TAKEOFFS: 0
10 FOOT SECTIONS: 3
| E-41, A | 1 | GENERATOR ROOM | CATERPILLAR | 3412 | 81Z17931 | EXCELLENT | DIESEL | 890 HP | EMERGENCY GENERATOR | |
| E-42A, B, C | 1 | GENERATOR ROOM | CATERPILLAR | SR-4 | 6FA10895 | EXCELLENT | ELEC. | 750KVA 664KW | ||
| (545KW PRIME) | EMERGENCY GENERATOR | |||||||||
| E-43 | 1-2 | 5105 | 2 @ 12V | LEAD ACID BATTERIES |
SERVING EMERGENCY GENERATOR
E-43A 1-2 B008 LEAD ACID BATTERY, SEALED TYPE
(GEL CELL)
SERVING FIRE ALARM SYSTEM
E-57 1 EB-41 CUTLER HAMMER / WESTINGHOUSE N48M28F45CU J95 F3033 45KVA
208V
| 125A | LOW VOLTAGE, DRY TYPE TRANSFORMER | ||||||
| 10 | PENTHOUSE | MAGNETEK | 223-0021-054 | 20KVA | LOW VOLTAGE, DRY TYPE TRANSFORMER |
SERVING SF-3
11 PENTHOUSE MAGNETEK 223-0021-054 20KVA LOW VOLTAGE, DRY TYPE TRANSFORMER
SERVING SF-4
12 PENTHOUSE MAGNETEK 223-0022-054 27KVA LOW VOLTAGE, DRY TYPE TRANSFORMER
SERVING SF-5
13 PENTHOUSE MAGNETEK 223-0021-054 20KVA LOW VOLTAGE, DRY TYPE TRANSFORMER
SERVING SF-6
14 PENTHOUSE MAGNETEK 223-0021-054 20KVA LOW VOLTAGE, DRY TYPE TRANSFORMER
SERVING SF-7
15 PENTHOUSE MAGNETEK 223-0021-054 20KVA LOW VOLTAGE, DRY TYPE TRANSFORMER
SERVING SF-8
16 PENTHOUSE MAGNETEK 223-0021-054 20KVA LOW VOLTAGE, DRY TYPE TRANSFORMER
SERVING SF-9
17 PENTHOUSE MAGNETEK 223-0021-054 20KVA LOW VOLTAGE, DRY TYPE TRANSFORMER
SERVING SF-10
18 PENTHOUSE MAGNETEK 223-0021-054 20KVA LOW VOLTAGE, DRY TYPE TRANSFORMER
SERVING SF-11