Equipment List W.B. Rudman FOB
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FormSF30.pdf | ||
| Q A_3.pdf | ||
| Q A_2.pdf | ||
| FormSF30.pdf | ||
| Q A_1.pdf | ||
| FormSF30.pdf | ||
| Preproposal_Minutes_3.12.2013.pdf | ||
| TAB_10-_RFP_Posted_Correct.pdf | ||
| TAB_10-_RFP_Posted_Correct.pdf | ||
| Pre-proposal_Conference_and_Site_Visit_Posting 1 .pdf | ||
| Cleveland_Equipment_Inventory_RFP.xlsx | XLSX spreadsheet | |
| RFP_Post.pdf | ||
| Rudman_Equipment_Inventory_RFP.xls | XLS spreadsheet | |
| RFP_2nd_LEVEL_REV.pdf | ||
| Synopsis.pdf | ||
| Pre-proposal_Conference_and_Site_Visit_Posting.doc | DOC document | |
| EQ_List_CLEV.doc | DOC document |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXHIBIT 5B GSA FORM 1736
BUILDING
W. B. Rudman Courthouse NH0038ZZ
| EQUIPMENT INVENTORY LIST |
| FIELD OFFICE |
Concord N.H.
DATE
May 23,2012
PREPARED BY
Randall Shaw
| PM GUIDE NUMBER |
| EQUIPMENT NUMBER |
| LOCATION |
| DESCRIPTION AND REMARKS |
| A-1 |
| 1 |
| Penthouse |
| AIR DRYER, REFRIGERATED. |
Mfr: Air compressor products Inc.
Model: ACP5RD
Ser.: 0331-101-9505-362N
R-134A
| A-3 |
| 1 |
| Penthouse |
| HUMIDIFICATION SYSTEM H-1 (for AHU-13) |
Mfr: Nortec Systems Inc.
Model: NHMC
Type: Electric
| A-4 |
| 1 |
| Penthouse |
| AIR COMPRESSORS |
Mfr: Air Compressor Products, Inc.
Model No: ACPGS02
Ser: A5032025
HP: Dual ½ HP Motors
Purpose: Pneumatics for valves on air handlers and pump packages
| A-4 |
| 2 |
| Penthouse |
| AIR COMPRESSORS |
Mfr: Air Compressor Products, Inc.
Model No: ACPGS02
Ser: A5032027
HP: Dual ½ HP Motors
Purpose: Pneumatics for valves on air handlers and pump packages
| A-5 |
| 1 |
| Room 1315 |
| AIR CONDITIONING MACHINE, SPLIT SYSTEM |
Mfr: Liebert Challenger 3000
Model: BK061G-AAE1
Ser: 336870-101
Tonnage: 5 (A-12-1&2)
| A-5 |
| 2 |
| Room 1315 |
| AIR CONDITIONING MACHINE, SPLIT SYSTEM |
Mfr: Liebert
Model: CR020RA1A7A665
Ser: N12EBM0051
Refr.: 410A Tonnage: 6
| A-5 |
| 3 |
| Room 1315 |
| AIR CONDITIONING MACHINE, SPLIT SYSTEM |
Mfr: Liebert
Model: CR020RA1A7A665
Ser: N12EBM0052
Refr.: 410A
Tonnage: 6
| A-5 |
| 4 |
| Room 105 |
AV Storage
AIR CONDITIONING MACHINE, SPLIT SYSTEM
Mfr: Carrier
Model : 40QNB012300
Volts: 208/230
Tonnage: 1
| A-5 |
| 5 |
| Room 4608 |
AIR CONDITIONING MACHINE, SPLIT SYSTEM
Mfr: Sanyo Model : KS1271 Volts: 208/230
Tonnage: 1 With Little Giant Pump, model: VCMA20ULST
| A-7 |
| 1 |
| Marshal Control Room |
| AIR-CONDITIONING MACHINE, PACKAGE UNIT. (special purpose) |
Mfr: Movincool
Model: Classic Plus 14
BTU’s: 10,000
Used during Cooling season only
| A-9 |
| 1 |
| Garage Ceiling |
| AIR-COOLED CONDENSER |
Mfr: Carrier
Model: 38AND12320
Ser: 1404Y20690
KW: .032 (1/44HP)
| 2 |
| Link Roof |
| AIR-COOLED CONDENSER |
Mfr: Liebert
Model: TCSV28K-A Ser: C12F2F2568 With VFD
| 3 |
| Link Roof |
| AIR-COOLED CONDENSER |
Mfr: Liebert
Model: TCSV28K-A
Ser: C12F2F2569
With VFD
| 4 |
| Upper roof, East side |
| AIR-COOLED CONDENSER |
Mfr: Sanyo Model: CL1271 Ser: 0078292 Tonnage : 1 Ref : 410A
| A-10 |
| 1 |
| Guard shack |
HEAT PUMP
Mfr : G.E.
Model : AJES12DCBM1
Ser : LH289120
| A-11 |
| 1 |
| Penthouse |
| AIR HANDLER AHU-1 |
Mfr: York
Model No: AP400FSAF30
Serial No: CFDM008149
CFM: 19,490
| A-11 |
| 2 |
| Penthouse |
| AIR HANDLER AHU-2 |
Mfr: York
Model No: AP215FSAFII20
Serial No: CFDM008154
CFM: 10,310
| A-11 |
| 3 |
| Penthouse |
| AIR HANDLER AHU-3 |
Mfr: York
Model No: AP305FSAF24
Serial No: CFDM008 155
CFM: 12,580
| A-11 |
| 4 |
| Penthouse |
| AIR HANDLER AHU-4 |
Mfr: York
Model No: AP215FSAFII20
Serial No: CFDM008156
CFM: 8,720
| A-11 |
| 5 |
| Penthouse |
| AIR HANDLER AHU-5 |
Mfr: York
Model No: AP305FSAFII24
Serial No: CFDM008157
CFM: 14,430
| A-11 |
| 6 |
| Penthouse |
| AIR HANDLER AHU-6 |
Mfr: York
Model No: AP150FSAFII16
Serial No: CFDM008158
CFM: 7,045
| A-11 |
| 7 |
| Penthouse |
| AIR HANDLER AHU-7 |
Mfr: York
Model No: AP120FSAFII15
Serial No: CFDM008159
CFM: 5,730
| A-11 |
| 8 |
| Penthouse |
| AIR HANDLER AHU-8 |
Mfr: York
Model No: AP170FSAFII18
Serial No: CFDM008160
CFM: 7,610
| A-11 |
| 9 |
| Penthouse |
| AIR HANDLER AHU-9 |
Mfr: York
Model No: AP170SFAFII18
Serial No: CFDM008161
CFM: 7,470
| A-11 |
| 10 |
| Penthouse |
| AIR HANDLER AHU-10 |
Mfr: York
Model No: AP150FSAFII6
Serial No: CFDM008150
CFM: 7,030
| A-11 |
| 11 |
| Penthouse |
| AIR HANDLER AHU-11 |
Mfr: York
Model No: AP250FSAF22
Serial No: CFDM008151
CFM: 11,520
| A-11 |
| 12 |
| Penthouse |
| AIR HANDLER AHU-12 |
Mfr: York
Model No: AP250FSAF22
Serial No: CFDM008152
CFM: 11,800
| A-11 |
| 13 |
| Penthouse |
| AIR HANDLER AHU-13 |
Mfr: York
Model No: AP305FSAF24
Serial No: CFDM008153
CFM: 13,895
| A-11 |
| 14 |
| Garage |
| AIR HANDLER HV-1 |
Mfr: York
Model No: AP400FSFC27X25
Serial No: CFDM008162
CFM: 25,000
| A-11 |
| 15 |
| Garage |
| AIR HANDLER HV-2 |
Mfr: York
Model No: AP400FSFC27X25
Serial No: CFDM008163
CFM: 25,000
| A-12 |
| 1 |
| Roof |
| GLYCOL DRY COOLER |
Mfr: Liebert
Model No: DSF 109Z
Serial No: 95070218
Tonnage: 4 (A-5-1)
| A-12 |
| 2 |
| Roof |
| GLYCOL DRY COOLER |
Mfr: Liebert
Model No: DNT 109A
Serial No: 0424C70899
Tonnage: 4 (A-5-2)
| C-2 |
| 1 |
| Penthouse |
Generator room Remote Air In-take Dampers, motorized. 24 X 24 inches, Intake air for generator room.
| C-2 |
| 2 |
| Penthouse |
Generator room Remote Air In-take Dampers, motorized. 54 X 72 inches, Intake air for generator room.
| C-2 |
| 3 |
| Penthouse |
Generator room Remote Air In-take Dampers, motorized. 60 X 72 inches, Exhaust air for generator room.
| C-2 |
| 4 |
| Penthouse |
Generator room Remote Air In-take Dampers, motorized. 18 X 72 inches, Mixed air for generator room.
| C-2 |
| 5 |
| Penthouse |
Roof, West side Remote Air In-take Dampers, motorized. 50 X 50 inches, Exhaust for smoke Evac. system EF-7.
| C-2 |
| 6 |
| Penthouse |
East side Remote Air In-take Dampers, motorized. 36 X 48 inches, air-intake for Penthouse.
| C-2 |
| 7 |
| Penthouse |
South side Remote Air Exhaust Dampers, 48 X 48 inches, air-Exhaust for Penthouse.
| C-3 |
| 1 |
| First Floor |
Room 1404
COILS, REHEAT TB-101
Area in SF: 1.22
| C-3 |
| 2 |
| First Floor |
Room 1412
COILS, REHEAT TB-102
Area in SF: 0.69
| C-3 |
| 3 |
| First Floor |
Room 1414
COILS, REHEAT TB-103
Area in SF: 1.22
| C-3 |
| 4 |
| First Floor |
Room 1414
COILS, REHEAT TB-104
Area in SF: 1.67
| C-3 |
| 5 |
| First Floor |
Room 1414
COILS, REHEAT TB-105
Area in SF: 0.69
| C-3 |
| 6 |
| First Floor |
Room 1424
COILS, REHEAT TB-106
Area in SF: 1.22
| C-3 |
| 7 |
| First Floor |
Room 1425
COILS, REHEAT TB-107
Area in SF: 0.69
| C-3 |
| 8 |
| First Floor |
Room 1424
COILS, REHEAT TB-108
Area in SF: 0.69
| C-3 |
| 9 |
| First Floor |
Room 1427
COILS, REHEAT TB-109
Area in SF: 0.69
| C-3 |
| 10 |
| First Floor |
Room 1100
COILS, REHEAT TB-110
Area in SF: 0.69
| C-3 |
| 11 |
| First Floor |
Room 1103
COILS, REHEAT TB-111
Area in SF: 0.69
| C-3 |
| 12 |
| First Floor |
Room 1103
COILS, REHEAT TB 112
Area in SF: 0.69
| C-3 |
| 13 |
| First Floor |
Room 1109
COILS, REHEAT TB-113
Area in SF: 0.69
| C-3 |
| 14 |
| First Floor |
Room 1106
COILS, REHEAT TB-114
Area in SF: 1.22
| C-3 |
| 15 |
| First Floor |
Room 1115
COILS, REHEAT TB-115
Area in SF: 0.69
| C-3 |
| 16 |
| First Floor |
Room 1115
COILS, REHEAT TB-116
Area in SF: 0.69
| C-3 |
| 17 |
| First Floor |
Room 1104
COILS, REHEAT TB-117
Area in SF: 0.83
| C-3 |
| 18 |
| First Floor |
Room 1513
COILS, REHEAT TB-118
Area in SF: 1.22
| C-3 |
| 19 |
| First Floor |
Room 1122
COILS, REHEAT TB-119
Area in SF: 1.22
| C-3 |
| 20 |
| First Floor |
Room 1121
COILS, REHEAT TB-120
Area in SF: 0.69
| C-3 |
| 21 |
| First Floor |
Room 1122
COILS, REHEAT TB-121
Area in SF: 0.69
| C-3 |
| 22 |
| First Floor |
Room 1124
COILS, REHEAT TB-122
Area in SF: 0.69
| C-3 |
| 23 |
| First Floor |
Room 1301
COILS, REHEAT TB-123
Area in SF: 1.67
| C-3 |
| 24 |
| First Floor |
Room 1301
COILS, REHEAT TB-124
Area in SF: 0.69
| C-3 |
| 25 |
| First Floor |
Ante Room 1303
COILS, REHEAT TB-125
Area in SF: 0.69
| C-3 |
| 26 |
| First Floor |
Corrider 1302
COILS, REHEAT TB-126
Area in SF: 0.69
| C-3 |
| 27 |
| First Floor |
Corrider 1302
COILS, REHEAT TB-127
Area in SF: 1.67
| C-3 |
| 28 |
| First Floor |
Room 1318
COILS, REHEAT TB-128
Area in SF: 0.69
| C-3 |
| 29 |
| First Floor |
Room 1316
COILS, REHEAT TB-129
Area in SF: 1.67
| C-3 |
| 30 |
| First Floor |
Room 1320
COILS, REHEAT TB-130
Area in SF: 1.22
| C-3 |
| 31 |
| First Floor |
Corrider 1314
COILS, REHEAT TB-131
Area in SF: 1.22
| C-3 |
| 32 |
| First Floor |
Room 1313
COILS, REHEAT TB-132
Area in SF: 1.22
| C-3 |
| 33 |
| First Floor |
Room 1322
COILS, REHEAT TB-133
Area in SF: 0.69
| C-3 |
| 34 |
| First Floor |
Room 1324
COILS, REHEAT TB-134
Area in SF: 0.69
| C-3 |
| 35 |
| First Floor |
Room 1325
COILS, REHEAT TB-135
Area in SF: 0.69
| C-3 |
| 36 |
| First Floor |
Room 1326
COILS, REHEAT TB-136
Area in SF: 0.69
| C-3 |
| 37 |
| First Floor |
Room 1329
COILS, REHEAT TB-137
Area in SF: 2.43
| C-3 |
| 38 |
| First Floor |
Corridor 1330
COILS, REHEAT TB-138
Area in SF: 0.69
| C-3 |
| 39 |
| First Floor |
Room 1711
COILS, REHEAT TB-139
Area in SF: 0.69
| C-3 |
| 40 |
| First Floor |
Room 1712
COILS, REHEAT TB-140
Area in SF: 0.69
| C-3 |
| 41 |
| First Floor |
Room 1709
COILS, REHEAT TB-141
Area in SF: 1.67
| C-3 |
| 42 |
| First Floor |
Room 1707
COILS, REHEAT TB-142
Area in SF: 0.69
| C-3 |
| 43 |
| First Floor |
Room 1706
COILS, REHEAT TB-143
Area in SF: 0.69
| C-3 |
| 44 |
| First Floor |
Room 1209
COILS, REHEAT TB-144
Area in SF: 2.43
| C-3 |
| 45 |
| First Floor |
Room 1209
COILS, REHEAT TB-145
Area in SF: 2.43
| C-3 |
| 46 |
| First Floor |
Room 1212
COILS, REHEAT TB-146
Area in SF: 0.69
| C-3 |
| 47 |
| First Floor |
Room 1210
COILS, REHEAT TB-147
Area in SF: 2.43
| C-3 |
| 48 |
| First Floor |
Room 1205
COILS, REHEAT TB-148
Area in SF: 1.67
| C-3 |
| 49 |
| First Floor |
Room 1204
COILS, REHEAT TB-149
Area in SF: 1.22
| C-3 |
| 50 |
| First Floor |
Room 1206
COILS, REHEAT TB-150
Area in SF: 0.69
| C-3 |
| 51 |
| First Floor |
Room 1705
COILS, REHEAT TB-151
Area in SF: 1.67
| C-3 |
| 52 |
| Second Floor |
Room 2407
COILS, REHEAT TB-201
Area in SF: 1.22
| C-3 |
| 53 |
| Second Floor |
Room 2404
COILS, REHEAT TB-202
Area in SF: 0.83
| C-3 |
| 54 |
| Second Floor |
Room 2407
COILS, REHEAT TB-203
Area in SF: 0.69
| C-3 |
| 55 |
| Second Floor |
Vestibule 2414
COILS, REHEATTB-204
Area in SF: 0.69
| C-3 |
| 56 |
| Second Floor |
Corridor 2417
COILS, REHEAT TB-205
Area in SF: 1.67
| C-3 |
| 57 |
| Second Floor |
Room 2422
COILS, REHEATTB-206
Area in SF: 2.92
| C-3 |
| 58 |
| Second Floor |
Room 2422
COILS, REHEAT TB-207
Area in SF: 2.92
| C-3 |
| 59 |
| Second Floor |
Room 2422
COILS, REHEAT TB-208
Area in SF: 2.43
| C-3 |
| 60 |
| Second Floor |
Room 2422
COILS, REHEATTB-209
Area in SF: 0.69
| C-3 |
| 61 |
| Second Floor |
Room 2422
COILS, REHEAT TB-210
Area in SF: 1.22
| C-3 |
| 62 |
| Second Floor |
Room 2422
COILS, REHEAT TB-211
Area in SF: 1.67
| C-3 |
| 63 |
| Second Floor |
Room 2424
COILS, REHEATTB-212
Area in SF: 0.69
| C-3 |
| 64 |
| Second Floor |
Room
COILS, REHEAT TB-213
Area in SF: 0.69
| C-3 |
| 65 |
| Second Floor |
Room 2426
COILS, REHEAT TB-214
Area in SF: 0.69
| C-3 |
| 66 |
| Second Floor |
Room 2429
COILS, REHEAT TB-215
Area in SF: 0.69
| C-3 |
| 67 |
| Second Floor |
Room 2301
COILS, REHEAT TB-216
Area in SF: 0.69
| C-3 |
| 68 |
| Second Floor |
Room 2302
COILS, REHEAT TB-217
Area in SF: 0.69
| C-3 |
| 69 |
| Second Floor |
Room 2305
COILS, REHEAT TB-218
Area in SF: 1.22
| C-3 |
| 70 |
| Second Floor |
Room 2329
COILS, REHEAT TB-219
Area in SF: 0.69
| C-3 |
| 71 |
| Second Floor |
Corridor 2304
COILS, REHEAT TB-220
Area in SF: 0.69
| C-3 |
| 72 |
| Second Floor |
Room 2307
COILS, REHEAT TB-221
Area in SF: 0.69
| C-3 |
| 73 |
| Second Floor |
Room 2309
COILS, REHEAT TB-222
Area in SF: 0.69
| C-3 |
| 74 |
| Second Floor |
Room 2310
COILS, REHEAT TB-223
Area in SF: 0.69
| C-3 |
| 75 |
| Second Floor |
Room 2311
COILS, REHEAT TB-224
Area in SF: 0.69
| C-3 |
| 76 |
| Second Floor |
Room 2316
COILS, REHEAT TB-225
Area in SF: 0.69
| C-3 |
| 77 |
| Second Floor |
Room 2318
COILS, REHEAT TB-226
Area in SF: 1.22
| C-3 |
| 78 |
| Second Floor |
Room 2313
COILS, REHEAT TB-227
Area in SF: 0.83
| C-3 |
| 79 |
| Second Floor |
Room 2623
COILS, REHEAT TB-228
Area in SF: 1.67
| C-3 |
| 80 |
| Second Floor |
Room 2626
COILS, REHEATTB-229
Area in SF: 2.43
| C-3 |
| 81 |
| Second Floor |
Room Room 2626
COILS, REHEATTB-230
Area in SF: 2.43
| C-3 |
| 82 |
| Second Floor |
Room 2623
COILS, REHEAT TB-231
Area in SF: 1.67
| C-3 |
| 83 |
| Second Floor |
Room 2219
COILS, REHEAT TB-232
Area in SF: 0.69
| C-3 |
| 84 |
| Second Floor |
Room 2217
COILS, REHEAT TB-233
Area in SF: 0.69
| C-3 |
| 85 |
| Second Floor |
Room 2216
COILS, REHEAT TB-234
Area in SF: 0.69
| C-3 |
| 86 |
| Second Floor |
Room 2212
COILS, REHEAT TB-235
Area in SF: 2.43
| C-3 |
| 87 |
| Second Floor |
Toilet 2208
COILS, REHEAT TB-236
Area in SF: 0.69
| C-3 |
| 88 |
| Second Floor |
Room 2211
COILS, REHEAT TB-237
Area in SF: 0.69
| C-3 |
| 89 |
| Second Floor |
Room 2212
COILS, REHEAT TB-238
Area in SF: 0.83
| C-3 |
| 90 |
| Second Floor |
Room 2227
COILS, REHEAT TB-239
Area in SF: 1.22
| C-3 |
| 91 |
| Second Floor |
Room 2227
COILS, REHEAT TB-240
Area in SF: 0.69
| C-3 |
| 92 |
| Second Floor |
Room 2203
COILS, REHEAT TB-241
Area in SF: 1.22
| C-3 |
| 93 |
| Second Floor |
Vault 2617
COILS, REHEAT TB-242
Area in SF: 1.22
| C-3 |
| 94 |
| Second Floor |
Room 2116
COILS, REHEAT TB-243
Area in SF: 0.69
| C-3 |
| 95 |
| Second Floor |
Room 2119
COILS, REHEAT TB-244
Area in SF: 1.22
| C-3 |
| 96 |
| Second Floor |
Corridor 2618
COILS, REHEAT TB-245
Area in SF: 1.22
| C-3 |
| 97 |
| Second Floor |
Corridor 2618
COILS, REHEAT TB-246
Area in SF: 1.67
| C-3 |
| 98 |
| Second Floor |
Room 2111
COILS, REHEAT TB-247
Area in SF: 1.67
| C-3 |
| 99 |
| Second Floor |
Corridor 2112
COILS, REHEAT TB-248
Area in SF: 0.69
| C-3 |
| 100 |
| Second Floor |
Waiting 2110
COILS, REHEAT TB-249
Area in SF: 1.22
| C-3 |
| 101 |
| Second Floor |
Room 2109
COILS, REHEAT TB-250
Area in SF: 1.67
| C-3 |
| 102 |
| Second Floor |
Room 2108
COILS, REHEAT TB-251
Area in SF: 1.67
| C-3 |
| 103 |
| Second Floor |
Room 2103
COILS, REHEAT TB-252
Area in SF: 2.92
| C-3 |
| 104 |
| Second Floor |
Room 2103
COILS, REHEAT TB-253
Area in SF: 1.22
| C-3 |
| 105 |
| Second Floor |
Room 2105
COILS, REHEAT TB-254
Area in SF: 2.92
| C-3 |
| 106 |
| Second Floor |
Room 2105
COILS, REHEAT TB-255
Area in SF: 2.43
| C-3 |
| 107 |
| Second Floor |
Room 2101
COILS, REHEAT TB-256
Area in SF: 0.83
| C-3 |
| 108 |
| Second Floor |
Room 2327
COILS, REHEAT TB-257
Area in SF: 0.69
| C-3 |
| 109 |
| Second Floor |
Corridor 2625
COILS, REHEAT TB-258
Area in SF: 0.56
| C-3 |
| 110 |
| Third Floor |
Corridor 3406
COILS, REHEAT TB-301
Area in SF: 1.22
| C-3 |
| 111 |
| Third Floor |
Room 3405
COILS, REHEAT TB-302
Area in SF: 0.69
| C-3 |
| 112 |
| Third Floor |
Corridor 3501
COILS, REHEAT TB-303
Area in SF: 2.92
| C-3 |
| 113 |
| Third Floor |
Room 3416
COILS, REHEAT TB-304
Area in SF: 0.69
| C-3 |
| 114 |
| Third Floor |
Corridor 3419
COILS, REHEAT TB-305
Area in SF: 0.69
| C-3 |
| 115 |
| Third Floor |
Corridor 3419
COILS, REHEAT TB-306
Area in SF: 1.22
| C-3 |
| 116 |
| Third Floor |
Corridor 3419
COILS, REHEAT TB-307
Area in SF: 0.69
| C-3 |
| 117 |
| Third Floor |
Room 3425
COILS, REHEAT TB-308
Area in SF: 2.43
| C-3 |
| 118 |
| Third Floor |
Room 3426
COILS, REHEAT TB-309
Area in SF: 2.43
| C-3 |
| 119 |
| Third Floor |
Room 3425
COILS, REHEAT TB-310
Area in SF: 0.83
| C-3 |
| 120 |
| Third Floor |
Room 3425
COILS, REHEAT TB-311
Area in SF: 0.83
| C-3 |
| 121 |
| Third Floor |
Room 3303
COILS, REHEAT TB-312
Area in SF: 1.67
| C-3 |
| 122 |
| Third Floor |
Room 3301
COILS, REHEAT TB-313
Area in SF: 0.69
| C-3 |
| 123 |
| Third Floor |
Room 3301
COILS, REHEAT TB-314
Area in SF: 0.69
| C-3 |
| 124 |
| Third Floor |
Room 3301
COILS, REHEAT TB-315
Area in SF: 2.92
| C-3 |
| 125 |
| Third Floor |
Room 3204
COILS, REHEAT TB-316
Area in SF: 1.67
| C-3 |
| 126 |
| Third Floor |
Room 3303
COILS, REHEAT TB-317
Area in SF: 2.92
| C-3 |
| 127 |
| Third Floor |
Room 3311
COILS, REHEAT TB-318
Area in SF: 1.67
| C-3 |
| 128 |
| Third Floor |
Room 3318
COILS, REHEAT TB-319
Area in SF: 0.69
| C-3 |
| 129 |
| Third Floor |
Corridor 3319
COILS, REHEAT TB-320
Area in SF: 1.22
| C-3 |
| 130 |
| Third Floor |
Room 3705
COILS, REHEAT TB-321
Area in SF: 0.83
| C-3 |
| 131 |
| Third Floor |
Corridor 3703
COILS, REHEAT TB-322
Area in SF: 2.92
| C-3 |
| 132 |
| Third Floor |
Corridor 3703
COILS, REHEAT TB-323
Area in SF: 2.43
| C-3 |
| 133 |
| Third Floor |
Room 3705
COILS, REHEAT TB-324
Area in SF: 0.69
| C-3 |
| 134 |
| Third Floor |
Corridor 3703
COILS, REHEAT TB-325
Area in SF: 2.92
| C-3 |
| 135 |
| Third Floor |
Toilet 3201
COILS, REHEAT TB-326
Area in SF: 2.43
| C-3 |
| 136 |
| Third Floor |
Room 3204
COILS, REHEAT TB-327
Area in SF: 2.43
| C-3 |
| 137 |
| Third Floor |
Room 3206
COILS, REHEAT TB-328
Area in SF: 0.69
| C-3 |
| 138 |
| Third Floor |
Room 3206
COILS, REHEAT TB-329
Area in SF: 0.69
| C-3 |
| 139 |
| Third Floor |
Room 3123
COILS, REHEAT TB-330
Area in SF: 0.83
| C-3 |
| 140 |
| Third Floor |
Room 3124
COILS, REHEAT TB-331
Area in SF: 0.69
| C-3 |
| 141 |
| Third Floor |
Room 3124
COILS, REHEAT TB-332
Area in SF: 2.43
| C-3 |
| 142 |
| Third Floor |
Room 3124
COILS, REHEAT TB-333
Area in SF: 2.43
| C-3 |
| 143 |
| Third Floor |
Room 3115
COILS, REHEAT TB-334
Area in SF: 0.69
| C-3 |
| 144 |
| Third Floor |
Room 3115
COILS, REHEAT TB-335
Area in SF: 0.69
| C-3 |
| 145 |
| Third Floor |
Room 3115
COILS, REHEAT TB-336
Area in SF: 0.69
| C-3 |
| 146 |
| Third Floor |
Vestibule 3103
COILS, REHEAT TB-337
Area in SF: 2.92
| C-3 |
| 147 |
| Third Floor |
Vestibule 3103
COILS, REHEAT TB-338
Area in SF: 0.69
| C-3 |
| 148 |
| Third Floor |
Room 3109
COILS, REHEAT TB-339
Area in SF: 0.69
| C-3 |
| 149 |
| Third Floor |
Corridor 3104
COILS, REHEAT TB-340
Area in SF: 1.22
| C-3 |
| 150 |
| Third Floor |
Room 3213
COILS, REHEAT TB-341
Area in SF: 0.83
| C-3 |
| 151 |
| Third Floor |
Room 3320
COILS, REHEAT TB-342
Area in SF: 0.69
| C-3 |
| 152 |
| Third Floor |
Corridor 3215
COILS, REHEAT TB-343
Area in SF: 1.22
| C-3 |
| 153 |
| Third Floor |
Room 3206
COILS, REHEAT TB-344
Area in SF: 2.92
| C-3 |
| 154 |
| Fourth Floor |
Room 4503
COILS, REHEAT TB-401
Area in SF: 0.69
| C-3 |
| 155 |
| Fourth Floor |
Room 4504
COILS, REHEAT TB-402
Area in SF: 0.83
| C-3 |
| 156 |
| Fourth Floor |
Room 4506
COILS, REHEAT TB-403
Area in SF: 1.22
| C-3 |
| 157 |
| Fourth Floor |
Room 4506
COILS, REHEAT TB-404
Area in SF: 1.22
| C-3 |
| 158 |
| Fourth Floor |
Room 4508
COILS, REHEAT TB-405
Area in SF: 1.22
| C-3 |
| 159 |
| Fourth Floor |
Room 4516
COILS, REHEAT TB-406
Area in SF: 0.69
| C-3 |
| 160 |
| Fourth Floor |
Room 4514
COILS, REHEAT TB-407
Area in SF: 0.83
| C-3 |
| 161 |
| Fourth Floor |
Room 4520
COILS, REHEAT TB-408
Area in SF: 1.22
| C-3 |
| 162 |
| Fourth Floor |
Room 4523
COILS, REHEAT TB-409
Area in SF: 0.69
| C-3 |
| 163 |
| Fourth Floor |
Room 4524
COILS, REHEAT TB-410
Area in SF: 0.69
| C-3 |
| 164 |
| Fourth Floor |
Corridor 4526
COILS, REHEAT TB-411
Area in SF: 1.22
| C-3 |
| 165 |
| Fourth Floor |
Room 4401
COILS, REHEAT TB-412
Area in SF: 2.92
| C-3 |
| 166 |
| Fourth Floor |
Room 4405
COILS, REHEAT TB-413
Area in SF: 0.69
| C-3 |
| 167 |
| Fourth Floor |
Room 4402
COILS, REHEAT TB-414
Area in SF: 0.69
| C-3 |
| 168 |
| Fourth Floor |
Room 4407
COILS, REHEAT TB-415
Area in SF: 0.83
| C-3 |
| 169 |
| Fourth Floor |
Room 4403
COILS, REHEAT TB-416
Area in SF: 1.22
| C-3 |
| 170 |
| Fourth Floor |
Room 4412
COILS, REHEAT TB-417
Area in SF: 0.69
| C-3 |
| 171 |
| Fourth Floor |
Room 4417
COILS, REHEAT TB-418
Area in SF: 0.69
| C-3 |
| 172 |
| Fourth Floor |
Room 4424
COILS, REHEAT TB-419
Area in SF: 0.69
| C-3 |
| 173 |
| Fourth Floor |
Room 4425
COILS, REHEAT TB-420
Area in SF: 0.69
| C-3 |
| 174 |
| Fourth Floor |
Room 4426
COILS, REHEAT TB-421
Area in SF: 0.69
| C-3 |
| 175 |
| Fourth Floor |
Room 4419
COILS, REHEAT TB-422
Area in SF: 0.83
| C-3 |
| 176 |
| Fourth Floor |
Room 4428
COILS, REHEAT TB-423
Area in SF: 1.22
| C-3 |
| 177 |
| Fourth Floor |
Room 4423
COILS, REHEAT TB-424
Area in SF: 0.69
| C-3 |
| 178 |
| Fourth Floor |
Room 4320
COILS, REHEAT TB425
Area in SF: 0.69
| C-3 |
| 179 |
| Fourth Floor |
Room 4321
COILS, REHEAT TB-426
Area in SF: 0.69
| C-3 |
| 180 |
| Fourth Floor |
Room 4322
COILS, REHEAT TB-427
Area in SF: 0.69
| C-3 |
| 181 |
| Fourth Floor |
Room 4324
COILS, REHEAT TB-428
Area in SF: 0.83
| C-3 |
| 182 |
| Fourth Floor |
Room 4326
COILS, REHEAT TB-429
Area in SF: 0.69
| C-3 |
| 183 |
| Fourth Floor |
Room 4329
COILS, REHEAT TB-430
Area in SF: 1.22
| C-3 |
| 184 |
| Fourth Floor |
Room 4618
COILS, REHEAT TB-431
Area in SF: 3.65
| C-3 |
| 185 |
| Fourth Floor |
Room 4618
COILS, REHEAT TB-432
Area in SF: 2.43
| C-3 |
| 186 |
| Fourth Floor |
Room 4618
COILS, REHEAT TB-433
Area in SF: 2.92
| C-3 |
| 187 |
| Fourth Floor |
Room 4613
COILS, REHEAT TB-434
Area in SF: 0.69
| C-3 |
| 188 |
| Fourth Floor |
Room 4613
COILS, REHEAT TB-435
Area in SF: 2.43
| C-3 |
| 189 |
| Fourth Floor |
Corridor 4315
COILS, REHEAT TB-436
Area in SF: 0.69
| C-3 |
| 190 |
| Fourth Floor |
Room 4602
COILS, REHEAT TB-437
Area in SF: 0.69
| C-3 |
| 191 |
| Fourth Floor |
Room 4306
COILS, REHEAT TB-438
Area in SF: 1.22
| C-3 |
| 192 |
| Fourth Floor |
Room 4306
COILS, REHEAT TB-439
Area in SF: 1.22
| C-3 |
| 193 |
| Fourth Floor |
Room 4306
COILS, REHEAT TB-440
Area in SF: 1.22
| C-3 |
| 194 |
| Fourth Floor |
Room 4603
COILS, REHEAT TB-441
Area in SF: 0.83
| C-3 |
| 195 |
| Fourth Floor |
Room 4307
COILS, REHEAT TB-442
Area in SF: 0.69
| C-3 |
| 196 |
| Fourth Floor |
Room 4310
COILS, REHEAT TB-443
Area in SF: 0.69
| C-3 |
| 197 |
| Fourth Floor |
Corridor 4315
COILS, REHEAT TB-444
Area in SF: 1.22
| C-3 |
| 198 |
| Fourth Floor |
Room 4112
COILS, REHEAT TB-445
Area in SF: 0.69
| C-3 |
| 199 |
| Fourth Floor |
Room 4113
COILS, REHEAT TB-446
Area in SF: 1.00
| C-3 |
| 200 |
| Fourth Floor |
Room 4110
COILS, REHEAT TB-447
Area in SF: 1.22
| C-3 |
| 201 |
| Fourth Floor |
Room 4110
COILS, REHEAT TB-448
Area in SF: 1.22
| C-3 |
| 202 |
| Fourth Floor |
Room 4104
COILS, REHEAT TB-449
Area in SF: 0.69
| C-3 |
| 203 |
| Fourth Floor |
Room 4117
COILS, REHEAT TB-450
Area in SF: 1.22
| C-3 |
| 204 |
| Fourth Floor |
Room 4122
COILS, REHEAT TB-451
Area in SF: 0.69
| C-3 |
| 205 |
| Fourth Floor |
Room 4114
COILS, REHEAT TB-452
Area in SF: 1.22
| C-3 |
| 206 |
| Fourth Floor |
Corridor 4201
COILS, REHEAT TB-453
Area in SF: 0.83
| C-3 |
| 207 |
| Fourth Floor |
Corridor 4201
COILS, REHEAT TB-454
Area in SF: 0.69
| C-3 |
| 208 |
| Fourth Floor |
Room 4126
COILS, REHEAT TB-455
Area in SF: 1.22
| C-3 |
| 209 |
| Fourth Floor |
Room 4207
COILS, REHEAT TB-456
Area in SF: 1.22
| C-3 |
| 210 |
| Fourth Floor |
Room 4210
COILS, REHEAT TB-457
Area in SF: 0.83
| C-3 |
| 211 |
| Fourth Floor |
Room 4213
COILS, REHEAT TB-458
Area in SF: 1.22
| C-3 |
| 212 |
| Fourth Floor |
Room 4211
COILS, REHEAT TB-459
Area in SF: 0.69
| C-3 |
| 213 |
| Fourth Floor |
Room 4217
COILS, REHEAT TB-460
Area in SF: 1.22
| C-3 |
| 214 |
| Fourth Floor |
Room 4212
COILS, REHEAT TB-461
Area in SF: 0.69
| C-3 |
| 215 |
| Fourth Floor |
Room 4218
COILS, REHEAT TB-462
Area in SF: 0.83
| C-3 |
| 216 |
| Fourth Floor |
Room 4227
COILS, REHEAT TB-463
Area in SF: 0.69
| C-3 |
| 217 |
| Fourth Floor |
Room 4230
COILS, REHEAT TB-464
Area in SF: 1.22
| C-3 |
| 218 |
| Fourth Floor |
Room 4219
COILS, REHEAT TB-465
Area in SF: 1.22
| C-3 |
| 219 |
| Fourth Floor |
Room 4232
COILS, REHEAT TB-466
Area in SF: 1.22
| C-3 |
| 220 |
| Fourth Floor |
Room 4232
COILS, REHEAT TB-467
Area in SF: 0.69
| C-4 |
| 1 |
| Mechanical contractors office, |
Penthouse work station.
CENTRAL MINI COMPUTER, HAVAC
Mfr: Johnson Controls
Model No: Metasys
NAE Controllers:
NAE: 1 total points 1,740
NAE: 2 total points 1,630
NAE: 3 total points 1,218
NAE: 4 total points including Fire Alarm 2,452
NAE: 5 total points 1,115
DX Controllers: 27 (13 AHUs, 2 HXs, & 1 Chiller in Penthouse and 7 FCUs, 2 H&Vs & 2 HXs in Garage)
DC-4-101/DC-4-168 Controllers: 68 (VAV Boxes on Floor 4)
DC-3-101/ DC-3-144 Controllers: 44 (VAV Boxes on Floor 3)
DC-3-145 UNT: 1 (Smoke Dampers on Floor 3)
DC-2-101/DC-2-158 Controllers: 58 (VAV Boxes on Floor 2)
DC-2-159/DC-2-161 UNT: 3 (Smoke Dampers for Floor 2)
DC-1-101/DC-1-151 Controllers: 51 (VAV Boxes for Floor 1)
DC-1-152/DC-1-156 (1 VAV & 4 UNT): 5 (Smoke Dampers for Floor 1)
ISN York Talk XL:1 part# 371-02085-001 (penthouse)
Basement EMS computer: Dell, Model: OPTIMLEX 755 Printer: Canon Pixma Model: IP4200 Monitor: Compaq Model: S700 with UPS Mfr: APC (on Cleveland Inventory) Rudman Penthouse EMS computer: Dell model: DHM. Ser: 5K8D941 Printer: Canon Pixma, Model: IP4200 Monitor: Dell, model: M782 with UPS Mfr: Cyber Power
| C-4 |
| 2 |
| Bldg. |
| CENTRAL MINI COMPUTER, ADVANCED METERING |
Penthouse:
Water Meters
Serves: Tower make-up and conductivity blow-off line -2 Basement, Entrance room -1
Basement Electrical room:
Mfr: Square D
Model: Power Logic
Type: ION 7650
Ser: LJ1102A694-02 Serves: Electric service
Basement
Mfr: GE Model: GE Sensing STPRE Serves: Steam service Cleveland Bldg.
Basement
Mfr: GE
Model: GE Sensing STPRE
Serves: Steam service Rudman Bldg Note*
Master Controller for both Buildings in the Cleveland Bldg.
| C-4 |
| 3 |
| Bldg. |
| CENTRAL MINI COMPUTER, LIGHTING CONTROL SYSTEM |
Mfr: Lightolier
Floors 1, 2, 3, 4, Phone rooms and 4th floor utility room
1) Cisco, Model: Catalyst 2960, Series SI -4
2) Lumenergi Box, Panel 1 -4 Lighting management Control system
Model: LMCS-PS-MKIII
A) PLN-60-12 -1
B) PLN-100-24 -2
3) Lighting management Control system, Panel 2
Model: LMCS-D-MKIII -4
Note* Additional power controllers and relay equipment in Electrical rooms
This Equipment answers to the Cleveland building Room 1003 utility closet.
| C-5 |
| 1 |
| First Floor |
Room 1404
AUTOMATIC MIXING BOX, ELECTRIC TB-101
Duct Size: 14x12-1/2
| C-5 |
| 2 |
| First Floor |
Corridor 1412
AUTOMATIC MIXING BOX, ELECTRIC TB-102
Duct Size: 10x10
| C-5 |
| 3 |
| First Floor |
Room 1414
AUTOMATIC MIXING BOX, ELECTRIC TB-103
Duct Size: 14x12-1/2
| C-5 |
| 4 |
| First Floor |
Room 1414
AUTOMATIC MIXING BOX, ELECTRIC TB-104
Duct Size: 16x15
| C-5 |
| 5 |
| First Floor |
Room 1414
AUTOMATIC MIXING BOX, ELECTRIC TB-105
Duct Size: 10x10
| C-5 |
| 6 |
| First Floor |
Room 1424
AUTOMATIC MIXING BOX, ELECTRIC TB-106
Duct Size: 14x12-1/2
| C-5 |
| 7 |
| First Floor |
Room 1425
AUTOMATIC MIXING BOX, ELECTRIC TB-107
Duct Size: 10x10
| C-5 |
| 8 |
| First Floor |
Room 1424
AUTOMATIC MIXING BOX, ELECTRIC TB-108
Duct Size: 10x10
| C-5 |
| 9 |
| First Floor |
Room 1427
AUTOMATIC MIXING BOX, ELECTRIC TB-109
Duct Size: 10x10
| C-5 |
| 10 |
| First Floor |
Room 1100
AUTOMATIC MIXING BOX, ELECTRIC TB-110
Duct Size: 10x10
| C-5 |
| 11 |
| First Floor |
Vestibule 1103
AUTOMATIC MIXING BOX, ELECTRIC TB-111
Duct Size: 10x10
| C-5 |
| 12 |
| First Floor |
Vestibule 1103
AUTOMATIC MIXING BOX, ELECTRIC TB-112
Duct Size: 10x10
| C-5 |
| 13 |
| First Floor |
Room 1109
AUTOMATIC MIXING BOX, ELECTRIC TB-113
Duct Size: 10x10
| C-5 |
| 14 |
| First Floor |
Corridor 1106
AUTOMATIC MIXING BOX, ELECTRIC TB-114
Duct Size: 14x12-1/2
| C-5 |
| 15 |
| First Floor |
Room 1115
AUTOMATIC MIXING BOX, ELECTRIC TB-115
Duct Size: 10x10
| C-5 |
| 16 |
| First Floor |
Room 1115
AUTOMATIC MIXING BOX, ELECTRIC TB-116
Duct Size: 10x10
| C-5 |
| 17 |
| First Floor |
Room 1104
AUTOMATIC MIXING BOX, ELECTRIC TB-117
Duct Size: 12x10
| C-5 |
| 18 |
| First Floor |
Room 1513
AUTOMATIC MIXING BOX, ELECTRIC TB-118
Duct Size: 14x12-1/2
| C-5 |
| 19 |
| First Floor |
Room 1122
AUTOMATIC MIXING BOX, ELECTRIC TB-119
Duct Size: 14x12-1/2
| C-5 |
| 20 |
| First Floor |
Room 1121
AUTOMATIC MIXING BOX, ELECTRIC TB-120
Duct Size: 10x10
| C-5 |
| 21 |
| First Floor |
Room 1122
AUTOMATIC MIXING BOX, ELECTRIC TB-121
Duct Size: 10x10
| C-5 |
| 22 |
| First Floor |
Room 1124
AUTOMATIC MIXING BOX, ELECTRIC TB-122
Duct Size: 10x10
| C-5 |
| 23 |
| First Floor |
Room 1301
AUTOMATIC MIXING BOX, ELECTRIC TB-123
Duct Size: 16x15
| C-5 |
| 24 |
| First Floor |
Room 13014
AUTOMATIC MIXING BOX, ELECTRIC TB-124
Duct Size: 10x10
| C-5 |
| 25 |
| First Floor |
Ante Room 1301
AUTOMATIC MIXING BOX, ELECTRIC TB-125
Duct Size: 10x10
| C-5 |
| 26 |
| First Floor |
Corridor 1302
AUTOMATIC MIXING BOX, ELECTRIC TB-126
Duct Size: 10x10
| C-5 |
| 27 |
| First Floor |
Corridor 1302
AUTOMATIC MIXING BOX, ELECTRIC TB-127
Duct Size: 16x15
| C-5 |
| 28 |
| First Floor |
Room 1318
AUTOMATIC MIXING BOX, ELECTRIC TB-128
Duct Size: 10x10
| C-5 |
| 29 |
| First Floor |
Room 1316
AUTOMATIC MIXING BOX, ELECTRIC TB-129
Duct Size: 16x15
| C-5 |
| 30 |
| First Floor |
Room 1320
AUTOMATIC MIXING BOX, ELECTRIC TB-130
Duct Size: 14x12-1/2
| C-5 |
| 31 |
| First Floor |
Corridor 1314
AUTOMATIC MIXING BOX, ELECTRIC TB-131
Duct Size: 14x12-1/2
| C-5 |
| 32 |
| First Floor |
Room 1313
AUTOMATIC MIXING BOX, ELECTRIC TB-132
Duct Size: 14x12-1/2
| C-5 |
| 33 |
| First Floor |
Room 1322
AUTOMATIC MIXING BOX, ELECTRIC TB-133
Duct Size: 10x10
| C-5 |
| 34 |
| First Floor |
Room 1324
AUTOMATIC MIXING BOX, ELECTRIC TB-134
Duct Size: 10x10
| C-5 |
| 35 |
| First Floor |
Room 1325
AUTOMATIC MIXING BOX, ELECTRIC TB-135
Duct Size: 10x10
| C-5 |
| 36 |
| First Floor |
Room 1326
AUTOMATIC MIXING BOX, ELECTRIC TB-136
Duct Size: 10x10
| C-5 |
| 37 |
| First Floor |
Room 1329
AUTOMATIC MIXING BOX, ELECTRIC TB-137
Duct Size: 20x17-1/2
| C-5 |
| 38 |
| First Floor |
Corridor 1330
AUTOMATIC MIXING BOX, ELECTRIC TB-138
Duct Size: 10x10
| C-5 |
| 39 |
| First Floor |
Room 1711
AUTOMATIC MIXING BOX, ELECTRIC TB-139
Duct Size: 10x10
| C-5 |
| 40 |
| First Floor |
Room 1712
AUTOMATIC MIXING BOX, ELECTRIC TB-140
Duct Size: 10x10
| C-5 |
| 41 |
| First Floor |
Room 1709
AUTOMATIC MIXING BOX, ELECTRIC TB-141
Duct Size: 16x15
| C-5 |
| 42 |
| First Floor |
Room 1707
AUTOMATIC MIXING BOX, ELECTRIC TB-142
Duct Size: 10x10
| C-5 |
| 43 |
| First Floor |
Room 1706
AUTOMATIC MIXING BOX, ELECTRIC TB-143
Duct Size: 10x10
| C-5 |
| 44 |
| First Floor |
Room 1209
AUTOMATIC MIXING BOX, ELECTRIC TB-144
Duct Size: 20x17-1/2
| C-5 |
| 45 |
| First Floor |
Room 1209
AUTOMATIC MIXING BOX, ELECTRIC TB-145
Duct Size: 24x17-1/2
| C-5 |
| 46 |
| First Floor |
Room 1212
AUTOMATIC MIXING BOX, ELECTRIC TB-146
Duct Size: 10x10
| C-5 |
| 47 |
| First Floor |
Room 1210
AUTOMATIC MIXING BOX, ELECTRIC TB-147
Duct Size: 20x17-1/2
| C-5 |
| 48 |
| First Floor |
Room 1205
AUTOMATIC MIXING BOX, ELECTRIC TB-148
Duct Size: 16x15
| C-5 |
| 49 |
| First Floor |
Room 1204
AUTOMATIC MIXING BOX, ELECTRIC TB-149
Duct Size: 14x12-1/2
| C-5 |
| 50 |
| First Floor |
Room 1206
AUTOMATIC MIXING BOX, ELECTRIC TB-150
Duct Size: 10x10
| C-5 |
| 51 |
| First Floor |
Room 1705
AUTOMATIC MIXING BOX, ELECTRIC TB-151
Duct Size: 16x15
| C-5 |
| 52 |
| Second Floor |
Room 2407
AUTOMATIC MIXING BOX, ELECTRIC TB-201
Duct Size: 14x12-1/2
| C-5 |
| 53 |
| Second Floor |
Room 2404
AUTOMATIC MIXING BOX, ELECTRIC TB-202
Duct Size: 12x10
| C-5 |
| 54 |
| Second Floor |
Room 2407
AUTOMATIC MIXING BOX, ELECTRIC TB-203
Duct Size: 10x10
| C-5 |
| 55 |
| Second Floor |
Vestibule 2414
AUTOMATIC MIXING BOX, ELECTRIC TB-204
Duct Size: 10x10
| C-5 |
| 56 |
| Second Floor |
Corridor 2417
AUTOMATIC MIXING BOX, ELECTRIC TB-205
Duct Size: 16x15
| C-5 |
| 57 |
| Second Floor |
Room 2422
AUTOMATIC MIXING BOX, ELECTRIC TB-206
Duct Size: 24x17-1/2
| C-5 |
| 58 |
| Second Floor |
Room 2422
AUTOMATIC MIXING BOX, ELECTRIC TB-207
Duct Size: 24x17-1/2
| C-5 |
| 59 |
| Second Floor |
Room 2422
AUTOMATIC MIXING BOX, ELECTRIC TB-208
Duct Size: 20x17-1/2
| C-5 |
| 60 |
| Second Floor |
Room 2422
AUTOMATIC MIXING BOX, ELECTRIC TB-209
Duct Size: 10x10
| C-5 |
| 61 |
| Second Floor |
Room 2422
AUTOMATIC MIXING BOX, ELECTRIC TB-210
Duct Size: 14x12-1/2
| C-5 |
| 62 |
| Second Floor |
Room 2422
AUTOMATIC MIXING BOX, ELECTRIC TB-211
Duct Size: 16x15
| C-5 |
| 63 |
| Second Floor |
Room 2424
AUTOMATIC MIXING BOX, ELECTRIC TB-212
Duct Size: 10x10
| C-5 |
| 64 |
| Second Floor |
Room 2425
AUTOMATIC MIXING BOX, ELECTRIC TB-213
Duct Size: 10x10
| C-5 |
| 65 |
| Second Floor |
Room 2426
AUTOMATIC MIXING BOX, ELECTRIC TB-214
Duct Size: 10x10
| C-5 |
| 66 |
| Second Floor |
Room 2429
AUTOMATIC MIXING BOX, ELECTRIC TB-215
Duct Size: 10x10
| C-5 |
| 67 |
| Second Floor |
Room2301
AUTOMATIC MIXING BOX, ELECTRIC TB-216
Duct Size: 10x10
| C-5 |
| 68 |
| Second Floor |
Room 2302
AUTOMATIC MIXING BOX, ELECTRIC TB-217
Duct Size: 10x10
| C-5 |
| 69 |
| Second Floor |
Room 2305
AUTOMATIC MIXING BOX, ELECTRIC TB-218
Duct Size: 14x12-1/2
| C-5 |
| 70 |
| Second Floor |
Room 2329
AUTOMATIC MIXING BOX, ELECTRIC TB-219
Duct Size: 10x10
| C-5 |
| 71 |
| Second Floor |
Corridor 2304
AUTOMATIC MIXING BOX, ELECTRIC TB-220
Duct Size: 10x10
| C-5 |
| 72 |
| Second Floor |
Room 2307
AUTOMATIC MIXING BOX, ELECTRIC TB-221
Duct Size: 10x10
| C-5 |
| 73 |
| Second Floor |
Room 2309
AUTOMATIC MIXING BOX, ELECTRIC TB-222
Duct Size: 10x10
| C-5 |
| 74 |
| Second Floor |
Room 2310
AUTOMATIC MIXING BOX, ELECTRIC TB-223
Duct Size: 10x10
| C-5 |
| 75 |
| Second Floor |
Room 2311
AUTOMATIC MIXING BOX, ELECTRIC TB-224
Duct Size: 10x10
| C-5 |
| 76 |
| Second Floor |
Room 2316
AUTOMATIC MIXING BOX, ELECTRIC TB-225
Duct Size: 10x10
| C-5 |
| 77 |
| Second Floor |
Room 2318
AUTOMATIC MIXING BOX, ELECTRIC TB-226
Duct Size: 14x12-1/2
| C-5 |
| 78 |
| Second Floor |
Room 2313
AUTOMATIC MIXING BOX, ELECTRIC TB-227
Duct Size: 12x10
| C-5 |
| 79 |
| Second Floor |
Room 2623
AUTOMATIC MIXING BOX, ELECTRIC TB-228
Duct Size: 16x15
| C-5 |
| 80 |
| Second Floor |
Room 2626
AUTOMATIC MIXING BOX, ELECTRIC TB-229
Duct Size: 20x17-1/2
| C-5 |
| 81 |
| Second Floor |
Room 2626
AUTOMATIC MIXING BOX, ELECTRIC TB-230
Duct Size: 20x17-1/2
| C-5 |
| 82 |
| Second Floor |
Room 2623
AUTOMATIC MIXING BOX, ELECTRIC TB-231
Duct Size: 16x15
| C-5 |
| 83 |
| Second Floor |
Room 2219
AUTOMATIC MIXING BOX, ELECTRIC TB-232
Duct Size: 10x10
| C-5 |
| 84 |
| Second Floor |
Room 2217
AUTOMATIC MIXING BOX, ELECTRIC TB-233
Duct Size: 10x10
| C-5 |
| 85 |
| Second Floor |
Room 2216
AUTOMATIC MIXING BOX, ELECTRIC TB-234
Duct Size: 10x10
| C-5 |
| 86 |
| Second Floor |
Room 2212
AUTOMATIC MIXING BOX, ELECTRIC TB-235
Duct Size: 20x17-1/2
| C-5 |
| 87 |
| Second Floor |
Toilet 2208
AUTOMATIC MIXING BOX, ELECTRIC TB-236
Duct Size: 10x10
| C-5 |
| 88 |
| Second Floor |
Room 2211
AUTOMATIC MIXING BOX, ELECTRIC TB-237
Duct Size: 10x10
| C-5 |
| 89 |
| Second Floor |
Room 2212
AUTOMATIC MIXING BOX, ELECTRIC TB-238
Duct Size: 12x10
| C-5 |
| 90 |
| Second Floor |
Room 2227
AUTOMATIC MIXING BOX, ELECTRIC TB-239
Duct Size: 14x12-1/2
| C-5 |
| 91 |
| Second Floor |
Room 2227
AUTOMATIC MIXING BOX, ELECTRIC TB-240
Duct Size: 10x10
| C-5 |
| 92 |
| Second Floor |
Room 2203
AUTOMATIC MIXING BOX, ELECTRIC TB-241
Duct Size: 14x12-1/2
| C-5 |
| 93 |
| Second Floor |
Vault 2617
AUTOMATIC MIXING BOX, ELECTRIC TB-242
Duct Size: 14x12-1/2
| C-5 |
| 94 |
| Second Floor |
Room 2116
AUTOMATIC MIXING BOX, ELECTRIC TB-243
Duct Size: 10x10
| C-5 |
| 95 |
| Second Floor |
Room 2219
AUTOMATIC MIXING BOX, ELECTRIC TB-244
Duct Size: 14x12-1/2
| C-5 |
| 96 |
| Second Floor |
Corridor 2618
AUTOMATIC MIXING BOX, ELECTRIC TB-245
Duct Size: 14x12-1/2
| C-5 |
| 97 |
| Second Floor |
Corridor 2618
AUTOMATIC MIXING BOX, ELECTRIC TB-246
Duct Size: 16x15
| C-5 |
| 98 |
| Second Floor |
Room 2111
AUTOMATIC MIXING BOX, ELECTRIC TB-247
Duct Size: 16x15
| C-5 |
| 99 |
| Second Floor |
Corridor 2112
AUTOMATIC MIXING BOX, ELECTRIC TB-248
Duct Size: 10x10
| C-5 |
| 100 |
| Second Floor |
Waiting 2110
AUTOMATIC MIXING BOX, ELECTRIC TB-249
Duct Size: 14x12-1/2
| C-5 |
| 101 |
| Second Floor |
Room 2109
AUTOMATIC MIXING BOX, ELECTRIC TB-250
Duct Size: 16x15
| C-5 |
| 102 |
| Second Floor |
Room 2108
AUTOMATIC MIXING BOX, ELECTRIC TB-251
Duct Size: 16x15
| C-5 |
| 103 |
| Second Floor |
Room 2103
AUTOMATIC MIXING BOX, ELECTRIC TB-252
Duct Size: 24x17-1/2
| C-5 |
| 104 |
| Second Floor |
Room 2105
AUTOMATIC MIXING BOX, ELECTRIC TB-253
Duct Size: 14x12-1/2
| C-5 |
| 105 |
| Second Floor |
Room 2105
AUTOMATIC MIXING BOX, ELECTRIC TB-254
Duct Size: 24x17-1/2
| C-5 |
| 106 |
| Second Floor |
Room 2105
AUTOMATIC MIXING BOX, ELECTRIC TB-255
Duct Size: 20x17-1/2
| C-5 |
| 107 |
| Second Floor |
Room 2101
AUTOMATIC MIXING BOX, ELECTRIC TB-256
Duct Size: 12x10
| C-5 |
| 108 |
| Second Floor |
Room 2327
AUTOMATIC MIXING BOX, ELECTRIC TB-257
Duct Size: 10x10
| C-5 |
| 109 |
| Second Floor |
Corridor 2625
AUTOMATIC MIXING BOX, ELECTRIC TB-258
Duct Size: 10x8
| C-5 |
| 110 |
| Third Floor |
Corridor 3406
AUTOMATIC MIXING BOX, ELECTRIC TB-301
Duct Size: 14x12-1/2
| C-5 |
| 111 |
| Third Floor |
Room 3405
AUTOMATIC MIXING BOX, ELECTRIC TB-302
Duct Size: 10x10
| C-5 |
| 112 |
| Third Floor |
Corridor 3501
AUTOMATIC MIXING BOX, ELECTRIC TB-303
Duct Size: 24x17-1/2
| C-5 |
| 113 |
| Third Floor |
Room 3416
AUTOMATIC MIXING BOX, ELECTRIC TB-304
Duct Size: 10x10
| C-5 |
| 114 |
| Third Floor |
Corridor 3419
AUTOMATIC MIXING BOX, ELECTRIC TB-305
Duct Size: 10x10
| C-5 |
| 115 |
| Third Floor |
Corridor 3419
AUTOMATIC MIXING BOX, ELECTRIC TB-306
Duct Size: 14x12-1/2
| C-5 |
| 116 |
| Third Floor |
Corridor 3419
AUTOMATIC MIXING BOX, ELECTRIC TB-307
Duct Size: 10x10
| C-5 |
| 117 |
| Third Floor |
Room 3425
AUTOMATIC MIXING BOX, ELECTRIC TB-308
Duct Size: 20x17-1/2
| C-5 |
| 118 |
| Third Floor |
Room 3426
AUTOMATIC MIXING BOX, ELECTRIC TB-309
Duct Size: 20x17-1/2
| C-5 |
| 119 |
| Third Floor |
Room 3425
AUTOMATIC MIXING BOX, ELECTRIC TB-310
Duct Size: 12x10
| C-5 |
| 120 |
| Third Floor |
Room 3425
AUTOMATIC MIXING BOX, ELECTRIC TB-311
Duct Size: 12x10
| C-5 |
| 121 |
| Third Floor |
Room 3303
AUTOMATIC MIXING BOX, ELECTRIC TB-312
Duct Size: 16x15
| C-5 |
| 122 |
| Third Floor |
Room 3301
AUTOMATIC MIXING BOX, ELECTRIC TB-313
Duct Size: 10x10
| C-5 |
| 123 |
| Third Floor |
Room 3301
AUTOMATIC MIXING BOX, ELECTRIC TB-314
Duct Size: 10x10
| C-5 |
| 124 |
| Third Floor |
Room 3301
AUTOMATIC MIXING BOX, ELECTRIC TB-315
Duct Size: 24x17-1/2
| C-5 |
| 125 |
| Third Floor |
Room 3204
AUTOMATIC MIXING BOX, ELECTRIC TB-316
Duct Size: 16x15
| C-5 |
| 126 |
| Third Floor |
Room 3303
AUTOMATIC MIXING BOX, ELECTRIC TB-317
Duct Size: 24x17-1/2
| C-5 |
| 127 |
| Third Floor |
Room 3311
AUTOMATIC MIXING BOX, ELECTRIC TB-318
Duct Size: 16x15
| C-5 |
| 128 |
| Third Floor |
Room 3318
AUTOMATIC MIXING BOX, ELECTRIC TB-319
Duct Size: 10x10
| C-5 |
| 129 |
| Third Floor |
Corridor 3319
AUTOMATIC MIXING BOX, ELECTRIC TB-320
Duct Size: 14x12-1/2
| C-5 |
| 130 |
| Third Floor |
Room 3705
AUTOMATIC MIXING BOX, ELECTRIC TB-321
Duct Size: 12x10
| C-5 |
| 131 |
| Third Floor |
Corridor 3705
AUTOMATIC MIXING BOX, ELECTRIC TB-322
Duct Size: 24x17-1/2
| C-5 |
| 132 |
| Third Floor |
Corridor 3703
AUTOMATIC MIXING BOX, ELECTRIC TB-323
Duct Size: 20x17-1/2
| C-5 |
| 133 |
| Third Floor |
Room 3705
AUTOMATIC MIXING BOX, ELECTRIC TB-324
Duct Size: 10x10
| C-5 |
| 134 |
| Third Floor |
Corridor 3703
AUTOMATIC MIXING BOX, ELECTRIC TB-325
Duct Size: 24x17-1/2
| C-5 |
| 135 |
| Third Floor |
Toilet 3201
AUTOMATIC MIXING BOX, ELECTRIC TB-326
Duct Size: 20x17-1/2
| C-5 |
| 136 |
| Third Floor |
Room 3204
AUTOMATIC MIXING BOX, ELECTRIC TB-327
Duct Size: 20x17-1/2
| C-5 |
| 137 |
| Third Floor |
Room 3206
AUTOMATIC MIXING BOX, ELECTRIC TB-328
Duct Size: 10x10
| C-5 |
| 138 |
| Third Floor |
Room 3206
AUTOMATIC MIXING BOX, ELECTRIC TB-329
Duct Size: 10x10
| C-5 |
| 139 |
| Third Floor |
Room 3123
AUTOMATIC MIXING BOX, ELECTRIC TB-330
Duct Size: 12x10
| C-5 |
| 140 |
| Third Floor |
Room 3124
AUTOMATIC MIXING BOX, ELECTRIC TB-331
Duct Size: 10x10
| C-5 |
| 141 |
| Third Floor |
Room 3124
AUTOMATIC MIXING BOX, ELECTRIC TB-332
Duct Size: 20x17-1/2
| C-5 |
| 142 |
| Third Floor |
Room 3124
AUTOMATIC MIXING BOX, ELECTRIC TB-333
Duct Size: 20x17-1/2
| C-5 |
| 143 |
| Third Floor |
Room 3115
AUTOMATIC MIXING BOX, ELECTRIC TB-334
Duct Size: 10x10
| C-5 |
| 144 |
| Third Floor |
Room 3115
AUTOMATIC MIXING BOX, ELECTRIC TB-335
Duct Size: 10x10
| C-5 |
| 145 |
| Third Floor |
Room 3115
AUTOMATIC MIXING BOX, ELECTRIC TB-336
Duct Size: 10x10
| C-5 |
| 146 |
| Third Floor |
Vestibule 3103
AUTOMATIC MIXING BOX, ELECTRIC TB-337
Duct Size: 24x17-1/2
| C-5 |
| 147 |
| Third Floor |
Vestibule 3103
AUTOMATIC MIXING BOX, ELECTRIC TB-338
Duct Size: 10x10
| C-5 |
| 148 |
| Third Floor |
Room 3109
AUTOMATIC MIXING BOX, ELECTRIC TB-339
Duct Size: 10x10
| C-5 |
| 149 |
| Third Floor |
Corridor 3104
AUTOMATIC MIXING BOX, ELECTRIC TB-340
Duct Size: 14x12-1/2
| C-5 |
| 150 |
| Third Floor |
Room 3213
AUTOMATIC MIXING BOX, ELECTRIC TB-341
Duct Size: 12x10
| C-5 |
| 151 |
| Third Floor |
Room 3320
AUTOMATIC MIXING BOX, ELECTRIC TB-342
Duct Size: 10x10
| C-5 |
| 152 |
| Third Floor |
Corridor 3215
AUTOMATIC MIXING BOX, ELECTRIC TB-343
Duct Size: 14x12-1/2
| C-5 |
| 153 |
| Third Floor |
Room 3206
AUTOMATIC MIXING BOX, ELECTRIC TB-344
Duct Size: 24x17-1/2
| C-5 |
| 154 |
| Fourth Floor |
Room 4503
AUTOMATIC MIXING BOX, ELECTRIC TB-401
Duct Size: 10x10
| C-5 |
| 155 |
| Fourth Floor |
Room 4504
AUTOMATIC MIXING BOX, ELECTRIC TB-402
Duct Size: 12x10
| C-5 |
| 156 |
| Fourth Floor |
Room 4503
AUTOMATIC MIXING BOX, ELECTRIC TB-403
Duct Size: 14x12-1/2
| C-5 |
| 157 |
| Fourth Floor |
Room 4506
AUTOMATIC MIXING BOX, ELECTRIC TB-404
Duct Size: 14x12-1/2
| C-5 |
| 158 |
| Fourth Floor |
Room 4508
AUTOMATIC MIXING BOX, ELECTRIC TB-405
Duct Size: 14x12-1/2
| C-5 |
| 159 |
| Fourth Floor |
Room 4516
AUTOMATIC MIXING BOX, ELECTRIC TB-406
Duct Size: 10x10
| C-5 |
| 160 |
| Fourth Floor |
Room 4514
AUTOMATIC MIXING BOX, ELECTRIC TB-407
Duct Size: 12x10
| C-5 |
| 161 |
| Fourth Floor |
Room 4520
AUTOMATIC MIXING BOX, ELECTRIC TB-408
Duct Size: 14x12-1/2
| C-5 |
| 162 |
| Fourth Floor |
Room 4523
AUTOMATIC MIXING BOX, ELECTRIC TB-409
Duct Size: 10x10
| C-5 |
| 163 |
| Fourth Floor |
Room 4524
AUTOMATIC MIXING BOX, ELECTRIC TB-410
Duct Size: 10x10
| C-5 |
| 164 |
| Fourth Floor |
Corridor 4526
AUTOMATIC MIXING BOX, ELECTRIC TB-411
Duct Size: 14x12-1/2
| C-5 |
| 165 |
| Fourth Floor |
Room 4401
AUTOMATIC MIXING BOX, ELECTRIC TB-412
Duct Size: 24x17-1/2
| C-5 |
| 166 |
| Fourth Floor |
Room 4405
AUTOMATIC MIXING BOX, ELECTRIC TB-413
Duct Size: 10x10
| C-5 |
| 167 |
| Fourth Floor |
Room 4402
AUTOMATIC MIXING BOX, ELECTRIC TB-414
Duct Size: 10x10
| C-5 |
| 168 |
| Fourth Floor |
Room 4407
AUTOMATIC MIXING BOX, ELECTRIC TB-415
Duct Size: 12x10
| C-5 |
| 169 |
| Fourth Floor |
Room 4403
AUTOMATIC MIXING BOX, ELECTRIC TB-416
Duct Size: 14x12-1/2
| C-5 |
| 170 |
| Fourth Floor |
Room 4412
AUTOMATIC MIXING BOX, ELECTRIC TB-417
Duct Size: 10x10
| C-5 |
| 171 |
| Fourth Floor |
Room 4417
AUTOMATIC MIXING BOX, ELECTRIC TB-418
Duct Size: 10x10
| C-5 |
| 172 |
| Fourth Floor |
Room 4424
AUTOMATIC MIXING BOX, ELECTRIC TB-419
Duct Size: 10x10
| C-5 |
| 173 |
| Fourth Floor |
Room 4425
AUTOMATIC MIXING BOX, ELECTRIC TB-420
Duct Size: 10x10
| C-5 |
| 174 |
| Fourth Floor |
Room 4426
AUTOMATIC MIXING BOX, ELECTRIC TB-421
Duct Size: 10x10
| C-5 |
| 175 |
| Fourth Floor |
Room 4419
AUTOMATIC MIXING BOX, ELECTRIC TB-422
Duct Size: 12x10
| C-5 |
| 176 |
| Fourth Floor |
Room 4428
AUTOMATIC MIXING BOX, ELECTRIC TB-423
Duct Size: 14x12-1/2
| C-5 |
| 177 |
| Fourth Floor |
Room 4423
AUTOMATIC MIXING BOX, ELECTRIC TB-424
Duct Size: 10x10
| C-5 |
| 178 |
| Fourth Floor |
Room 4320
AUTOMATIC MIXING BOX, ELECTRIC TB-425
Duct Size: 10x10
| C-5 |
| 179 |
| Fourth Floor |
Room 4321
AUTOMATIC MIXING BOX, ELECTRIC TB-426
Duct Size: 10x10
| C-5 |
| 180 |
| Fourth Floor |
Room 4322
AUTOMATIC MIXING BOX, ELECTRIC TB-427
Duct Size: 10x10
| C-5 |
| 181 |
| Fourth Floor |
Room 4324
AUTOMATIC MIXING BOX, ELECTRIC TB-428
Duct Size: 12x10
| C-5 |
| 182 |
| Fourth Floor |
Room 4326
AUTOMATIC MIXING BOX, ELECTRIC TB-429
Duct Size: 10x10
| C-5 |
| 183 |
| Fourth Floor |
Room 4329
AUTOMATIC MIXING BOX, ELECTRIC TB-430
Duct Size: 14x12-1/2
| C-5 |
| 184 |
| Fourth Floor |
Room 4618
AUTOMATIC MIXING BOX, ELECTRIC TB-431
Duct Size: 30x17-1/2
| C-5 |
| 185 |
| Fourth Floor |
Room 4618
AUTOMATIC MIXING BOX, ELECTRIC TB-432
Duct Size: 20x17-1/2
| C-5 |
| 186 |
| Fourth Floor |
Room 4618
AUTOMATIC MIXING BOX, ELECTRIC TB-433
Duct Size: 24x17-1/2
| C-5 |
| 187 |
| Fourth Floor |
Room 4613
AUTOMATIC MIXING BOX, ELECTRIC TB-434
Duct Size: 10x10
| C-5 |
| 188 |
| Fourth Floor |
Room 4613
AUTOMATIC MIXING BOX, ELECTRIC TB-435
Duct Size: 20x17-1/2
| C-5 |
| 189 |
| Fourth Floor |
Corridor 4315
AUTOMATIC MIXING BOX, ELECTRIC TB-436
Duct Size: 10x10
| C-5 |
| 190 |
| Fourth Floor |
Room 4602
AUTOMATIC MIXING BOX, ELECTRIC TB-437
Duct Size: 10x10
| C-5 |
| 191 |
| Fourth Floor |
Room 4306
AUTOMATIC MIXING BOX, ELECTRIC TB-438
Duct Size: 14x12-1/2
| C-5 |
| 192 |
| Fourth Floor |
Room 4306
AUTOMATIC MIXING BOX, ELECTRIC TB-438
Duct Size: 14x12-1/2
| C-5 |
| 193 |
| Fourth Floor |
Room 4306
AUTOMATIC MIXING BOX, ELECTRIC TB-440
Duct Size: 14x12-1/2
| C-5 |
| 194 |
| Fourth Floor |
Room 4603
AUTOMATIC MIXING BOX, ELECTRIC TB-441
Duct Size: 12x10
| C-5 |
| 195 |
| Fourth Floor |
Room 4307
AUTOMATIC MIXING BOX, ELECTRIC TB-442
Duct Size: 10x10
| C-5 |
| 196 |
| Fourth Floor |
Room 4310
AUTOMATIC MIXING BOX, ELECTRIC TB-443
Duct Size: 10x10
| C-5 |
| 197 |
| Fourth Floor |
Corridor 4315
AUTOMATIC MIXING BOX, ELECTRIC TB-444
Duct Size: 14x12-1/2
| C-5 |
| 198 |
| Fourth Floor |
Room 4112
AUTOMATIC MIXING BOX, ELECTRIC TB-445
Duct Size: 10x10
| C-5 |
| 199 |
| Fourth Floor |
Room 4113
AUTOMATIC MIXING BOX, ELECTRIC TB-446
Duct Size: 12x12
| C-5 |
| 200 |
| Fourth Floor |
Room 4110
AUTOMATIC MIXING BOX, ELECTRIC TB-447
Duct Size: 14x12-1/2
| C-5 |
| 201 |
| Fourth Floor |
Room 4110
AUTOMATIC MIXING BOX, ELECTRIC TB-448
Duct Size: 14x12-1/2
| C-5 |
| 202 |
| Fourth Floor |
Room 4104
AUTOMATIC MIXING BOX, ELECTRIC TB-449
Duct Size: 10x10
| C-5 |
| 203 |
| Fourth Floor |
Room 4117
AUTOMATIC MIXING BOX, ELECTRIC TB-450
Duct Size: 14x12-1/2
| C-5 |
| 204 |
| Fourth Floor |
Room 4122
AUTOMATIC MIXING BOX, ELECTRIC TB-451
Duct Size: 10x10
| C-5 |
| 205 |
| Fourth Floor |
Room 4114
AUTOMATIC MIXING BOX, ELECTRIC TB-452
Duct Size: 14x12-1/2
| C-5 |
| 206 |
| Fourth Floor |
Corridor 4201
AUTOMATIC MIXING BOX, ELECTRIC TB-453
Duct Size: 12x10
| C-5 |
| 207 |
| Fourth Floor |
Corridor 4201
AUTOMATIC MIXING BOX, ELECTRIC TB-454
Duct Size: 10x10
| C-5 |
| 208 |
| Fourth Floor |
Room 4126
AUTOMATIC MIXING BOX, ELECTRIC TB-455
Duct Size: 14x12-1/2
| C-5 |
| 209 |
| Fourth Floor |
Room 4207
AUTOMATIC MIXING BOX, ELECTRIC TB-456
Duct Size: 14x12-1/2
| C-5 |
| 210 |
| Fourth Floor |
Room 4210
AUTOMATIC MIXING BOX, ELECTRIC TB-457
Duct Size: 12x10
| C-5 |
| 211 |
| Fourth Floor |
Room 4213
AUTOMATIC MIXING BOX, ELECTRIC TB-458
Duct Size: 14x12-1/2
| C-5 |
| 212 |
| Fourth Floor |
Room 4211
AUTOMATIC MIXING BOX, ELECTRIC TB-459
Duct Size: 10x10
| C-5 |
| 213 |
| Fourth Floor |
Room 4217
AUTOMATIC MIXING BOX, ELECTRIC TB-460
Duct Size: 14x12-1/2
| C-5 |
| 214 |
| Fourth Floor |
Room 4212
AUTOMATIC MIXING BOX, ELECTRIC TB-461
Duct Size: 10x10
| C-5 |
| 215 |
| Fourth Floor |
Room 4218
AUTOMATIC MIXING BOX, ELECTRIC TB-462
Duct Size: 12x10
| C-5 |
| 216 |
| Fourth Floor |
Room 4227
AUTOMATIC MIXING BOX, ELECTRIC TB-463
Duct Size: 10x10
| C-5 |
| 217 |
| Fourth Floor |
Room 4230
AUTOMATIC MIXING BOX, ELECTRIC TB-464
Duct Size: 14x12-1/2
| C-5 |
| 218 |
| Fourth Floor |
Room 4219
AUTOMATIC MIXING BOX, ELECTRIC TB-465
Duct Size: 14x12-1/2
| C-5 |
| 219 |
| Fourth Floor |
Room 4232
AUTOMATIC MIXING BOX, ELECTRIC TB-466
Duct Size: 14x12-1/2
| C-5 |
| 220 |
| Fourth Floor |
Room 4232
AUTOMATIC MIXING BOX, ELECTRIC TB-467
Duct Size: 10x10
| C-6 |
| 1 thru 8,155 |
| Throughout Building |
| CONTROLS, CENTRAL SYSTEM, HVAC |
Type: Direct Digital Control except for pneumatically operated valves on the air handlers and pump packages
FX Backnet devices (4 between both buildings)
VAV Air Handlers: (13 units)
Temperature Sensors: 52
Low Pressure Switches: 13
High Pressure Switches: 26
Air Flow stations: 11
End Switches: 65
C02 Telaire: 1
Cooling Tower: FX07 1
Freeze Protection Thermostats: 13
Static Pressure Sensors: 13
Humidistat (AHU-13 only): 1
Air Handlers, Carbon Dioxide Dect.: 14
Garage H&V Units (2 units)
Temperature Sensors: 4
High Pressure Switches: 3
End Switches: 4
Freeze Protection Thermostats: 2
CO Monitor: 4
VAV Boxes (219 units)
Space Thermostats: 219
Fan Coil Units (7 units)
Space Thermostats: 7
Fin Tube Radiation and Convectors (8 units)
Space thermostats: 8
Cabinet and Unit Heaters (5 units)
Space Thermostats: 5
Mechanical Room Ventilation
Space Thermostats: 1
AHU System
Occupancy points: 15
C-6
CONTROLS, CENTRAL SYSTEM, HVAC (cont.)
Return and Fin Tube Hot Water Heating System
Return Flow Transmitter: 1
Supply Flow Transmitter: 1
Temperature Sensor: 3
Condensate Heat Recovery System
PH Monitor: 1
Temperature Sensor: 3
Chilled Water & Condenser Water Piping
Flow Control Devices: 2
Snow Melting System in Driveway:
Service Switch: 1
Snow/Ice Detector: 2
Slab Sensor: 2
Supply Sensor: 1
Return Sensor: 1
Snow Melting System in Front Stairs:
Service Switch: 1
Supply Sensor: 1
Snow Melting System in Parking lot:
Service Switch: 1
Supply Sensor: 2
Rain water system 3
Tower filtration system
Lighting Control system
| C-7 |
| 1 |
| Garage |
North Wall
CONDENSATE PUMP CP-1
Mfr: Shipco
Model: 603PCD3
Serial No: 12382
Motor HP: 2 (Dual Motors)
| C-7 |
| 2 |
| Garage by Stair # 3 |
| CONDENSATE PUMP CP-2 |
Mfr: Shipco
Model: 372PCD3
Serial No: 12383
Motor HP: 1 (Dual Motors)
| C-7 |
| 3 |
| Garage by Stair # 3 |
| CONDENSATE PUMP CP-3 |
Mfr: Roth
Model: Hoffman
Serial No: 254A-42
Motor HP: 3/4 (Dual Motors)
| C-9/10 |
| 1 |
| Roof |
| COOLING TOWER CT-1 |
Mfr: Evapco
Model: AT8-912B
Ser.: 941722
Tonnage: 300
| C-9/10 |
| 2 |
| Roof |
| COOLING TOWER CT-2 |
Mfr: Evapco
Model: AT8-912B
Ser.: 941721 Tonnage: 300
| D-1 |
| 1-2 |
| Garage |
| DOOR, POWER OPERATED |
Mfr: Rytec Model: Spiral High Performance Doors Ser.: 80197 (out) 80196 (in)
Type: High Performance Door Motor/gear box; 460V
| D-1 |
| 3 |
| Salleyport |
| DOOR, POWER OPERATED |
Mfr: Cornell Ironworks
Model: ACGL-50
Ser: 12007
Type: Overhead Roll-up (out)
Motor Size: 1/2 HP
| D-1 |
| 4 |
| Salleyport |
| DOOR, POWER OPERATED |
Mfr: Cornell Ironworks
Model: ACGL-50
Ser: 12008
Type: Overhead Roll-up (in)
Motor Size: 1/2 HP
| D-1 |
| 5 |
| Loading Dock |
| DOOR, POWER OPERATED |
Mfr: Wayne Dalton
Model: T3311L4 E79930
Ser: 2511N0091
Type: Overhead Sectional
Motor Size: 1/3 HP AO Smith
DOM: 6 13 2011
| D-1 |
| 6 |
| Loading Dock |
| DOOR, POWER OPERATED |
Mfr: Wayne Dalton
Model: T3311L4 E79930
Ser: 2511N0092
Type: Overhead Sectional
Motor Size: 1/3 HP AO Smith
DOM: 6 13 2011
| D-1 |
| 7 |
| Court Room 3 |
| CURTAIN, POWER OPERATED |
Mfr: Skylite
| D-1 |
| 8 |
| Garage, Judges Parking area |
| DOOR, POWER OPERATED |
Mfr: Lift Master
Model: SL595-100-83-H3
Type: Rolling Fenced Gate
Also noted under G-3
| D-1 |
| 9 |
| Garage, Marshal parking area |
| DOOR, POWER OPERATED |
Mfr: Lift Master
Model: SL595-100-83-H3
Type: Rolling Fenced Gate
Also noted under G-3
| D-3 |
| 1-11 |
| Main Roof |
| DRAINS, ROOF |
5” - 7 drains
4” - 3 drains
3” - 1 drain
| D-3 |
| 12-13 |
| Link Roof |
| DRAINS, ROOF |
3” - 2 drains
| D-3 |
| 14-113 |
| Main Roof |
| DRAINS, ROOF, GUTTERING |
LN. Ft 100
| D-4 |
| 1-2 |
| Main Entrance |
| DOORS, AUTOMATIC - ELECTRIC |
Mfr: Stanley Magic Doors
Operator: Stanley Magic Swing Concealed Swing Door Operator
Power: 117 Volt, 60 HZ, 1 phase, 15 Amp
| D-5 |
| 1 |
| Main Entrance |
| DOOR, MAIN ENTRANCE, REVOLVING |
Mfr: Crane
| 2 |
| Grounds |
Guard shack
DOOR, MAIN ENTRANCE
| 3 |
| West Stairway, Ground floor |
| DOOR, MAIN ENTRANCE |
| 4 |
| East Stairway, Ground floor |
| DOOR, MAIN ENTRANCE |
| 5-6 |
| Loading Dock |
| DOORS, MAIN ENTRANCE |
| D-6 |
| 1-16 |
| Penthouse |
| DRAINS, FLOOR |
4” - 16 drains
| D-6 |
| 17-22 |
| Terrace |
| DRAINS, DECK |
4” - 6 drains
| D-6 |
| 23-46 |
| Garage |
| DRAINS, FLOOR |
4” - 22 drains
6” - 2 drains
| D-6 |
| 47 |
| Garage |
| DRAINS, TRENCH - 1 drain |
| D-6 |
| 48-49 |
| Outside Garage Doors |
| DRAINS, TRENCH - 2 drains |
| D-6 |
| 50-53 |
| Areaways |
| DRAINS, AREAWAY |
4” - 4 drains
| D-6 |
| 54-55 |
| Grounds, West side Lawn area |
| DRAINS, STORM |
2 drains
| E-1/2/3/4/8/9 |
| 1 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity: 5500 lbs.
No. of Floors Served: 3
| E-1/2/3/4/8/9 |
| 2 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity: 4500 lbs.
No. of Floors Served: 3
| E-1/2/3/4/8/9 |
| 3 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity: 4000 lbs.
No. of Floors Served: 3
| E-1/2/3/4/8/9 |
| 4 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity: 4000 lbs.
No. of Floors Served: 3
| E-1/2/3/4/8/9 |
| 5 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity: 3000 lbs.
No. of Floors Served: 5
| E-1/2/3/4/8/9 |
| 6 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity: 3000 lbs.
No. of Floors Served: 4
| E-1/2/3/4/8/9 |
| 7 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity: 4500 lbs.
No. of Floors Served: 5
| E-1/2/3/4/8/9 |
| 8 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity: 4000 lbs.
No. of Floors Served: 4
| E-1/2/3/4/8/9 |
| 9 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity: 4000 lbs.
No. of Floors Served: 3
| E-1/2/3/4/8/9 |
| 10 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity: 4000 lbs.
No. of Floors Served: 3
| E-1/2/3/4/8/9 |
| 11 |
| Vertical Transportation |
| ELEVATOR, HYDRAULIC |
Mfr: Cab - Bryce Southern
Hydraulics - Canton Elevator
Electronics - Motion Control
Capacity 4500 lbs.
No. of Floors Served: 6
| E-26 |
| 1 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Main Breaker
Cubicle #: 1
Mfr: Cutler Hammer/ Westinghouse
Model No: DS 632
Serial No: 6616C36G04
Voltage: 480/277
Amps: 3,200
| E-26 |
| 2 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Panel DH1
Cubicle #: 3
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 600
| E-26 |
| 3 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Panel DH2
Cubicle #: 4
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 600
| E-26 |
| 4 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Panel DH3
Cubicle #: 5
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 600
| E-26 |
| 5 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Panel DH4
Cubicle #: 6
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 600
| E-26 |
| 6 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Panel PHB
Cubicle #: 7
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 400
| E-26 |
| 7 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Panel PHM
Cubicle #: 8
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 600
| E-26 |
| 8 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Spare
Cubicle #: 9
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 600
| E-26 |
| 9 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: ATS#1
Cubicle #: 10
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 400
| E-26 |
| 10 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: ATS#2
Cubicle #: 11
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 1,200
| E-26 |
| 11 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: ATS#3
Cubicle #: 12
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 1,200
| E-26 |
| 12 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Chiller #1
Cubicle #: 13
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 600
| E-26 |
| 13 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Chiller #2
Cubicle #: 14
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 600
| E-26 |
| 14 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Spare
Cubicle #: 15
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 400
| E-26 |
| 15 |
| EB-40, Main Switchboard Room |
| LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER |
Purpose: Spare
Cubicle #: 16
Mfr: Cutler Hammer/ Westinghouse
Model No:
Serial No:
Voltage:
Amps: 400
| E-30 |
| 1 |
| EB-40, Main Switchboard Room |
| SWITCHBOARDS, MEDIUM VOLTAGE |
Mfr: Cutler Hammer/ Westinghouse
Model No: POW-R-LINE
Serial No: HUBS53167
No. of Cubicles: 19
13 active cubicles (one with owner metering)
3 spare cubicles
3 space and hardware cubicles
| E-33 |
| 1 |
| EB-40 |
| HIGH VOLTAGE NETWORK AND POWER DRY TYPE TRANSFORMER. |
Mfr: Cutler Hammer/ Westinghouse
Model No: Instruction Book 43500-054-11
Serial No: 956014-A1
KVA: 2,000
Voltage: 13,800 delta/480Y/277
Amperage: 111.6-3208
Rating: 5.51
| E-34 |
| 1 |
| EB-40 |
| DISCONNECTS, ISOLATING SWITCH. |
Mfr: Cutler Hammer/ Westinghouse
Volts: 13,800 Delta
Main Service Disconnect
| E-34A |
| 1-2 |
| Room B017 |
| DISCONNECTS, ISOLATING SWITCH. |
Mfr: Cutler Hammer/ Westinghouse
125 AMP
Shunt trip for Elevators
| E-34A |
| 3 |
| Room B006 |
| DISCONNECTS, ISOLATING SWITCH. |
Mfr: Cutler Hammer/ Westinghouse
125 AMP
Shunt trip for Elevator
| E-34A |
| 4 |
| Room B005 |
| DISCONNECTS, ISOLATING SWITCH. |
Mfr: Cutler Hammer/ Westinghouse
125 AMP
Shunt trip for Elevator
| E-34A |
| 5-6 |
| Room B010 |
| DISCONNECTS, ISOLATING SWITCH. |
Mfr: Cutler Hammer/ Westinghouse
125 AMP
Shunt trip for Elevators
| E-34A |
| 7-9 |
| Room B009 |
| DISCONNECTS, ISOLATING SWITCH. |
Mfr: Cutler Hammer/ Westinghouse
125 AMP
Shunt trip for Elevators
| E-34A |
| 10 |
| Room B020 |
| DISCONNECTS, ISOLATING SWITCH. |
Mfr: Cutler Hammer/ Westinghouse
100 AMP
Shunt trip for Elevator
| E-34A |
| 11 |
| Room B022 |
| DISCONNECTS, ISOLATING SWITCH. |
Mfr: Cutler Hammer/ Westinghouse
125 AMP
Shunt trip for Elevator
| E-35 |
| 1 |
| Penthouse outside Room 5105 |
| MOTOR CONTROL CENTER (MCC) under 100 HP |
Mfr: Cutler Hammer/ Westinghouse (HUBS53167)(IT.OO4 FVC)
Size: Series 2100
Rating: 600A, 277/480V, 3 phase, 4 wire
No. of Motor Starters: 5active
1 spare
3 space
| E-35 |
| 2 |
| Garage, EB-42 |
| MOTOR CONTROL CENTER (MCC) under 100 HP |
Mfr: Cutler Hammer/ Westinghouse (HUBS53167)
Size: Series 2100
Rating: 600A, 277/480V, 3 phase, 4 wire
No. of Motor Starters: 2 active
1 spare
2 space
| E-35 |
| 3 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH501-010-4-00P2 M2796
Ser: 150232 950623
Serves: SF-6
| E-35 |
| 4 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH501-003-4-00P2 M2796
Ser: 150137 950622
Serves: RF-6
| E-35 |
| 5 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH501-015-4-00P2 M2796
Ser: 150466 950627
Serves: SF 12
| E-35 |
| 6 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH550-UH-08A8-4 M2796
Ser: 2104202228
Serves: RF 12
| E-35 |
| 7 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH501-015-4-00P2 M2796
Ser: 150468 950628
Serves: SF 11
| E-35 |
| 8 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH501-005-4-00P2 M2796
Ser: 150578 950628
Serves: RF 11
| E-35 |
| 9 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH501-020-4-00P2 M2796
Ser: 150169 950622
Serves: SF 5
| E-35 |
| 10 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH501-007-4-00P2 M2796
Ser: 150140 950622
Serves: SF 5
| E-35 |
| 11 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH501-010-4-00P2 M2796
Ser: 150375 950626
Serves: SF-9
| E-35 |
| 12 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH550-UH-08A8-4 M2796
Ser: 2090900853
Serves: RF 9
| E-35 |
| 13 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH501-015-4-00P2 M2796
Ser: 150464 950627
Serves: SF 3
| E-35 |
| 14 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH550-UH-08A8-4 M2796
Ser: 2082303493
Serves: RF 3
| E-35 |
| 15 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model: ACH501-015-4-00P2 M2796
Ser: 150467 950627
Serves: SF 2
| E-35 |
| 16 |
| Penthouse |
| MOTOR CONTROL CENTER VFD |
Mfr: Asea Brown Boveri
Model:…