About this file

This document includes a federal contract solicitation and supporting files for a quality assurance materials testing laboratory to support construction of safety modifications to the Moose Creek Dam in North Pole, Alaska. The solicitation requests establishment of a validated materials testing laboratory at the project staging area to independently monitor soil-cement-bentonite and soils work throughout the duration of the project. The scope of services required under this contract include site preparation and utilities for the physical laboratory structure and office, materials testing laboratory development with required equipment, processes and validation by the US Army Corps of Engineers ERDC, and performance of QA duties on the construction of a partial-depth barrier wall through approximately 4.5 miles of the Moose Creek Dam embankment consisting of soil-cement-bentonite. The supporting files provide plans for the reserved areas for the QA laboratory and field office at the project site.

View the file

Other files

File Type Posted
W911KB21R0053 Amendment 3.pdf PDF
Potential Offeror Questions- revised 8Sep21.pdf PDF
Potential Offeror Questions- 2Sep21.pdf PDF
GFI-1-AM02-01SEP21.pdf PDF
W911KB21R00530002 Amendment 2.pdf PDF
W911KB21R00530001 Amendment1.pdf PDF
GFI-3 Dwgs-CHL023-RFP.pdf PDF
GFI-2 Specs-CHL023-RFP.pdf PDF
W911KB21R0053.pdf PDF
GFI-4.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

C

C

E

S

R

O

A

D

S

O

U

T H

E

E

P

A

G

L L E

C

T

A

N

N

E

L

A

C

C

E

A

D

S

O

U

E

P

A

G

L

L

E

C

T

A

N

N

E

L

L

A

K

P

A

D

L

A

U

R

A

N

A

D

L

A

U

R

A

N

A

D

A

S

P

H

A

L

R

K

I N

G

150' x 230' AREA RESERVED FOR

GOVERNMENT FIELD OFFICE

AND GOVERNMENT TOILET

FACILITIES (BY OTHERS)

70' x 150' AREA RESERVED FOR

GOVERNMENT QA LAB

N3,940,240

E1,449,685

N3,940,540

E1,449,835

D R

A W

I N

G

F I L E

D W

G

S

C A

L E

P L O

T

S

C A

L E

D A

T E

A C

T I O

N S

Y M

D R

A W

N

R E

S I D

E N

T

E

N G

I N

E E

R

D A

T E

S T

A T

E

P R

I M

E

C

O N

T R

A C

T O

R

D A

T E

D E

S C

R I P

T I O

N A

P P

D

C I T

Y

C O

N T

R A

C T

O R

C O

N T

R A

N

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

S U

B M

I T

T E

D

D E

S I G

N E

D

R E

V I E

W E

D

C H

I E

F

B

A

N C

H

C H

I E

C

T I O

N

U S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

A N

C H

O R

A G

E

A

L A

S K

A

C O

R P

S

O

F

E

N G

I N

E E

R S

REFERENCE

NUMBER:

SHEET OF

A

B

C

D

E

F

G

H

1 2 3 4 5 6 7 8 9 10 11 12

US Army Corps of Engineers ® Alaska District

VERIFY SCALES: BAR IS ONE INCH

ON ORIGINAL DRAWING

0 1"

R T

H

P

O L

E

A

L A

S K

A

M O

O S

E

C

R E

D

M

F

E T

Y

M

O D

I F

I C

A T

I O

N

M

Y

D r a w i n g

O

E

N P r i v a t e

E

S E

S S

G

I

O

J E

L

E S h e n a r o j e c t C

H L

M

D o d

C o n t r a c t i n g C o n s t r u c t i o n

Q

A

L a b

C

A D

C

H L

Q

A d w g l a s t s a v e d o n

P

M w a s p l o t t e d b y

A l l e y

M i c h a e l

W

V

U

A

R M

Y

C

E P

U

S A o n

P

M

T

E D

Q U

A L

I T

Y

A

S S

U R

A N

L

B

O R

A T

O R

Y

P

L A

N

GFI-1

0 500'250'

QA LAB PLAN

A1

SCALE: 1" = 200'

BACKGROUND IMAGE FROM

UNKNOWN SOURCE, DATED 18

MAY 2015. UNO, THE IMAGE IS

PROVIDED FOR GENERAL

REFERENCE ONLY.

SCALE: 1" = 50'

INSET A

D8

SEE INSET A

NOTES:

1. THIS WILL BE THE ACCESS ROAD UNTIL THE BARRIER

WALL CONTRACTOR ESTABLISHES THE SOUTH

BORROW ACCESS ROAD, SEE GFM-2.

2. THE QA LAB WILL BE LIMITED TO THIS AREA.

ESTABLISH VEHICULAR ACCESS ON THE EAST

BOUNDARY AS REQUIRED BY THE SCOPE OF WORK.

SEE NOTE 1

150' x 230' AREA RESERVED

FOR GOVERNMENT FIELD

OFFICE AND GOVERNMENT

TOILET FACILITIES (BY

OTHERS)

70' x 150' AREA RESERVED

FOR GOVERNMENT QA LAB

SEE NOTE 2

PHOTO 1: QA LABORATORY SITE JUNE 2020

PHOTO 1

ACCESS GATE

AutoCAD SHX Text

Sheets and Views
E-101 OHE SERVICE ROUTING
A1 - LOW POINT DRAIN SITE PLAN (S-101)
A1 - CONTROL WORKS SITE PLAN (S-102)
A1 - MACHINE ROOM SLAB PLAN (S-103)
E1 - CONTROL WORKS DECK AND SOUTH APPROACH LOAD LIMITS (S-103)
A6 - NORTH SUPPORT WALL ELEVATION (S-103)
C6 - DOWNSTREAM SUPPORT WALL ELEVATION (S-103)
A10 - SHEET PILE TIE-IN (S-101)
A1 - SUBSURFACE OBSTRUCTIONS NEAR CONTROL WORKS (S-104)
F10 - NOTES (S-101)
C11 - NOTES (S-103)
A1 - OH ELECTRICAL SERVICE ROUTING (E-101)

File details come from the government source that posted it. Updated .