FY23 Oregon II Register of Lifting Appliances.pdf

PDF 2 MB Posted

Attached to
1305M223QNMAN0129 - NOAA's Ship Oregon II Drydock FY 2024
Solicitation number
1305M223QNMAN0129
Issued by

About this file

This solicitation package includes documents for a ship drydocking opportunity with the National Oceanic and Atmospheric Administration. Specifically, the solicitation requests quotations for drydocking NOAA's Ship Oregon II in fiscal year 2024. The statement of work outlines requirements including haul out, inspection, maintenance, repairs as needed, re-launch, and associated services over approximately 30 days. Offerors must complete past performance, accounting, and pricing attachments to be considered for this work requiring a drydocking yard along the Gulf Coast or East Coast of the United States. The solicitation requests quotations by April 15, 2023 and anticipates awarding a firm fixed-price contract for the work period of July 2024.

View the file

Other files

File Type Posted
ATTACHMENT D5 Pricing Schedule O2 DD FY24_Updated.xlsx XLSX spreadsheet
Amendment_0002_1305M223QNMAN0129_Signed.pdf PDF
MRG Pic_2.jpg JPG image
R2_NONE_OT-S22-0-2-1_RevNONE_Sht1 OF 1_N_A_OT-S22-0-2-1.pdf PDF
AMC-581-1A-Inspection and Preservation of Ground Tackle (4 sheets).pdf PDF
R2-S92-0-3 Rev K 1989 Ships Service Switch Gear Wiring Diagram_Update.PDF PDF
FY23 Oregon II Life Raft-Immersion Suit _ Life Jacket Inspection Reports.pdf PDF
Oregon II MRG List of Materials_Update.pdf PDF
MRG Pic_1.jpg JPG image
Cooper_Bearing_Manual_2_Update.jpg JPG image
Cooper_Bearing_Manual_1_Update.jpg JPG image
MRG Pic_3.jpg JPG image
Amendment_0001_1305M223QNMAN0129_Signed.pdf PDF
Oregon II MRG List of Materials.pdf PDF
Oregon II Hydraulic Hose List (2)_Update.xlsx XLSX spreadsheet
OT-S48-1-1 (2)_Update.pdf PDF
FY23 Oregon II Register of Lifting Appliance_Update.pdf PDF
R2_NONE_OT-S17-1-3-1_RevNONE_Sht1 OF 1_N_A_OT-S17-1-3-1 (2)_Update.pdf PDF
OT-S48-3-3 Firemain and Sea Service System_Update.pdf PDF
AMC-300-1_Overhaul_of_Electrical_Rotating_Machinery_(10_pages) (1) (2).pdf PDF
0606- Standards for Lifting Appliances on NOAA Ships.doc DOC document
OT-S43-1-1.pdf PDF
FY21 Oregon II Annual Fire Inspection Report.pdf PDF
OT-S11-1-1(P) (1).pdf PDF
ATTACHMENT D2 Past Performance Information Form.docx DOCX document
OT-S11-1-1.pdf PDF
OT-S11-6-1 (1).pdf PDF
R2_NONE_S41-5-5_RevNONE_Sht6_N_OT-S41-5-5-6 (1).pdf PDF
OT-S3801-101 (1).pdf PDF
OT-S48-3-3 Firemain and Sea Service System.pdf PDF
OT-S41-5-5.pdf PDF
ATTACHMENT D6 Accounting System Questionnaire .pdf PDF
NOAA Standard Specification S2906 Arc Welding on Waterborne Vessels _ June 1982.pdf PDF
OT-S3801-12.pdf PDF
OT-S45-1-2 (2).pdf PDF
Engineering Report ER20200324_NO2 UPS Review.pdf PDF
R2_NONE_S38-1-14_RevNONE_Sht4_N_OT-S38-1-14-4.pdf PDF
OT-S11-0-1-1 (1).pdf PDF
MOC-573-2 Overhaul Repair of Hyd Cyls.pdf PDF
OT-S3801-11.pdf PDF
R2_NONE_S38-1-14_RevNONE_Sht5_N_OT-S38-1-14-5.pdf PDF
OR-S62-0-10 Elect One Line (MRP 1998) with Galley Update.pdf PDF
AMC-573-1C Weight Handling Gear Testing.pdf PDF
OR-S21-0-4 sheet 2 of 8.pdf PDF
ATTACHMENT D1 NOAA Ship Oregon II FY 2024 Drydock Specs.pdf PDF
s1205 Zinc Protectors.pdf PDF
OR-S21-0-4 sheet 5 of 8.pdf PDF
ATTACHMENT D5 Pricing Schedule O2 DD FY24.xlsx XLSX spreadsheet
AMC-000-1G General Requirements for Ship Repair Contract Work on NOAA Ships.pdf PDF
R2_NONE_S11-0-3_RevNONE_Sht1_N_OT-S11-0-3-1 (2) (2).pdf PDF
Show 40 more

Latest 50 of 133 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

“ Accredited By The U.S. Department of Labor Under 29 CFR Part 1919 ”

CRANE INSPECTION SERVICES, INC.

P. O. Box 461 • Fairhope, AL 36533

Office (251)928-6262

WWW.CRANEINSPECTION.COM

1563-AL

January 23, 2023

REGISTER OF SHIP’S LIFTING APPLIANCES

AND CARGO HANDLING GEAR

Name of Ship: OREGON II

Official Numbers:

ABS Class # 6703512 (Load Line Only)

IMO# 6728068

Hull# R332

Call Sign: WTDO

Port of Registry: Pascagoula, MS

Name of Owner: NOAA

Register Number: 1563-AL

Date of Issue: 01/23/23

Issued By: Crane Inspection Services, Inc.

Signature: Thomas Pritchett - President

Certificate of Unit Test and/or Examination of Crane, Derrick, or Other Material

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

Certificate No. 1563-100 ANNUAL

1926, 1910, ANSI B30.6

1. Owner NOAA 151 Watts Ave Pascagoula, MS 39567

2. Description (check): Location:

Crane (describe type (truck, rail, etc.)) Vessel Mounted (a) Remains at worksite If (a) or (c), describe:

Derrick (describe) Aft Deck Crane - (b) Changes Worksite Mounted on the Ship

Other (describe) (c) Aboard vessel Oregon II

If spout or other device, Aft Deck describe:

Manufacturer Alaska Telescopic Crane Model MCT-1040 Serial No. MCT-1040-90-556

Owner’s Identification, if any OREGON II (Aft Deck Cranel)

3. Service status at time of survey (check):

Lifting Magnet Max SWL 4,050 @ 40FT.

Clamshell Other (describe):

4. Boom at time of survey (except bridge cranes):

Length 22'-40' Type Tubular Box

5. Test loads applied (cross out if only examination conducted):

Radius Proof Loads Rated Loads 40 ft. 5,680 lb. 4,050 lb.

XXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXX

Means of application of proof load: Scaled Water Weights Basis for assigned load ratings: Posted Rating

6. Remarks and/or limitations imposed:

7. Load indicating or limited device (check): Fitted Not fitted Accuracy

I certify that on the 23rd day of January, 2023, the above described device was (tested and examined) by the undersigned or his authorized representative, that said (test and examination) met in all respects with the requirements of the Division of Occupational Safety and Health as per OSHA 1910, 1926, & ANSI. Any deficiencies considered to constitute an unsatisfactory conditions have/been corrected; and that the device has been found to be in compliance in all applicable respects with the governing requirements.

Name and address of accredited or otherwise authorized organization making the test and/or examination:

Crane Inspection Services, Inc. P.O. Box 461 Fairhope, AL 36533 Name and address of authorized person carrying out the test and/or examination: Position of signatory in the organization making the Flynn Pritchett test and/or examination:

Crane Inspection Services, Inc. Surveyor P.O. Box 461 Fairhope, AL 36533 Signature

Date 01.23.23

OWNER’S COPY CERTIFICATING DUPLICATE

“Accredited By California Division of Occupational Safety and Health”

Supplement “B” and “C” Attached

SUPPLEMENT "B" - APPLICABLE TO CRANE INSPECTION SERVICES, INC. INSPECTION REPORTS

Inspection reports are based upon observed procedures and inspections performed by Crane Inspection Services, Inc. representatives, but are not intended to replace or supersede the necessity for routine or preventative maintenance or procedures recommended by others, such as, but not limited to manufacturers, operators, and other inspecting organizations or persons.

Referral to applicable regulations is essential with regard to responsibilities of owners and users for use, maintenance, and normal operational inspections. It is especially important that owners and users, regularly and by means of extraordinary disassembly and/or non-destructive testing, arrange to effectively examine parts of the equipment which may be reasonably accessible by routine examinations, including such examinations by Crane Inspection Services, Inc. representatives.

Equipment owners and users should assure continuous compliance with all manufacturer, regulatory, and other applicable performance specifications, including but not limited to, full range accuracy of load indicating devices, machinery, etc., regardless of the extent to which specifications can be evaluated during Crane Inspection Services, Inc.'s inspections.

Other requirements of applicable Federal and State regulations not specifically considered within the scope or recorded by related Crane Inspection Services, Inc.'s reports, remain for the continuing attention and responsibility of equipment owners and users, including but not limited to, adequate lighting, walkways, ladders, stairways, clearance between moving and fixed structures, electrical motor restart lockouts, fire extinguishers in the vicinity, etc.

SUPPLEMENT "C" - GENERAL TERMS AND CONDITIONS

Crane Inspection Services, Inc. will provide, upon reasonable request, a Representative to witness tests of equipment as conducted and/or arranged by such company or person, and to complete related inspections in accordance with applicable regulations and standards to facilitate the issue of associated certificates which will be processed and provided by Crane Inspection Services, Inc., P. O. Box 461, Fairhope, AL 36533-0461.

No terms or conditions contained in any acceptance or acknowledgment regarding Crane Inspection Services, Inc. shall be effective against or binding upon or shall otherwise make Crane Inspection Services, Inc. liable, upon any obligation or upon any theory of breach of warranty, express or applied in law or for any obligation, warranty, guaranty, or other undertaking, unless expressly agreed to in writing by an instrument signed by an authorized officer of Crane Inspection Services, Inc.

Unless otherwise specifically provided for by associated Crane Inspection Services, Inc.'s documents, forms, diagrams, or correspondence, Crane Inspection Services, Inc.'s approval of the working capability of equipment certified or documented is restricted to the certification or documentation of the capability demonstrated and attested to by the specific tests to and inspections of such equipment accomplished in accordance with corresponding standards and requirements for such tests and inspections as established by applicable prevailing Regulations, and consistent with the rated lifting capacity of such equipment as previously documented by other recognized organizations and/or authorities.

Crane Inspection Services, Inc. assumes no responsibility for any damages caused by equipment tests arranged by or with the permission of the Owners of the equipment, nor does Crane Inspection Services, Inc. assume responsibility for testing devices and/or weights provided by or with the permission of the Owners of such equipment. Owners of equipment certified or documented by Crane Inspection Services, Inc. should arrange to demonstrate for Crane Inspection Services, Inc.

documentation and/or otherwise maintain a record of and present to Crane Inspection Services, Inc. verification as to the certified accuracy of testing devices and/or certified weights of test loads utilized in connection with related Crane Inspection Services, Inc.'s certifications and documentations.

All equipment should be rigged and employed in an approved and safe manner consistent with corresponding manufacturer specifications and associated certifications and documentations. Crane Inspection Services, Inc. assumes no responsibility for maintenance or proper use or possible misuse of such equipment, and equipment is certified or documented by Crane Inspection Services, Inc. as being in apparent satisfactory condition only to the extent determined by the tests witnessed and the physical examinations reasonably completed. Additionally, it is the responsibility of the user and/or the Owner of the equipment to assure proper use of and to service, repair, or replace the equipment or the components of the equipment as necessary, consistent with any associated Crane Inspection Services, Inc. recommendations and/or occurring conditions in order to insure the continued satisfactory condition of the equipment subsequent to the effective date of and within the intent of the associated Crane Inspection Services, Inc.'s certificate(s) and documentation(s) issued.

Crane Inspection Services, Inc.'s certifications and documentations do not include certification, documentation, or any other approval for or relating to the stability of, means of attachment to, or structural suitability of working surfaces, platforms, piers, vessels, or the like upon which Crane Inspection Services, Inc. inspected equipment may be located or to which Crane Inspection Services, Inc.'s inspected equipment may be attached and placed in service, as such matters of stability, attachment, and structural suitability are not within the intended or the offered scope of Crane Inspection Services, Inc.'s jurisdiction or services.

NOTE: SUPPLEMENTS “A”, “B” & “C” ARE PART OF THIS REPORT.

1 CRANE INSPECTION SERVICES, INC.

Office (251)928-6262 • Fax (251)990-6133

CODE: 1563-100 DATE: 01/23/23

CUSTOMER:___NOAA / Regal Services___________________________ ADDRESS: ___151 Watts Ave Pascagoula, MS 39567__________________

TELEPHONE: __(251) 622-1266__________________

SITE CONTACT: ___Mr. Mark Langner__________________________ SURVEYOR: __Mr. Flynn Pritchett_______________________________ INITIAL INSPECTION (YES/NO): _____ RE-INSPECTION (YES/NO):__Yes____ DATE, AGENCY & NUMBER OF LAST LOAD TEST:_Marine Industrial 2021 DATE, AGENCY & NUMBER OF LAST ANNUAL INSP.:Marine Industrial 2021_

PURPOSE OF SURVEY QUAD:____ ANNUAL:_X__ SPECIAL:____

JURISDICTION 1910:__X_ 1926:__X___ ANSI STANDARD:__B30.22 & B30.5

OTHER:_______________________________

DECRIPTION OF CRANE:_ Telescopic Boom Crane Mounted on Vessel – Oregon II_______ MANUFACTURER: ___Alaska Telescopic Crane_____ MODEL#__MCT-1040_________ S/N__MCT-1040-90-556___________ MAX CAPACITY__4,050 lb @ 40 Ft.______ OWNER IDENTIFICATION:____Oregon II Aft Telescopic Boom Crane_______________

SERVICE STATUS: LIFTING:_X___ CLAMSHELL: ____

MAGNET:____OTHER:__Hook

DESCRIPTION OF PROOF LOAD:__Scaled Water Weights_________

BASIS FOR ASSIGNED LOAD RATINGS: __STABILITY RATING CHART __________

OTHER:_____________________________________________________________________________

REMARKS AND/OR

LIMITATIONS:______________N/A____________________________________

RADIUS PROOF LOAD RATED LOAD OUTRIGGERS

(YES, NO)

BOOM DIRECTION

(OVER REAR/SIDE)

40ft 5,680 lb. 4,050 lb. N/A REAR

2 CRANE INSPECTION SERVICES, INC.

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

CODE: 1563-100 DATE: 01/23/23

ANNUAL CHECKSHEET:

BOOM INFORMATION

1. Boom:

Manufactures Designation _______N/A_________ Sections Identified ___2_____

Boom Length: Min.___22_ Ft. Max. __40_____ Ft.

Draw Sketch of Number and Length of Boom Sections:

Type Boom, Steel Truss with:

Cords: Angular __N/A___ Tubular ___N/A___ Other ____X_______

Lacings: Angular __N/A___ Tubular ___N/A___ Other ____N/A_____

2. Jib:

Manufactures Designation _______N/A_________ Sections Identified ____N/A____

Jib Length: _ N/A _ Ft.

Draw Sketch of Number and Length of Jib Sections:

Cords: Angular __N/A___ Tubular __N/A____ Other ____N/A_____

Lacings: Angular __N/A___ Tubular __N/A____ Other ____N/A_____

Type of jib stops ___N/A________________________________________

HOOK INFORMATION

TRAM: _4 ¼” HOOK: _2 ¾” HOOK INSPECTION:_OK

3 CRANE INSPECTION SERVICES, INC.

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

CODE: 1563-100 DATE: 01/23/23

N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U

1. GENERAL

APPEARANCE

25. LOAD BLOCK/GRAPPLE

2. Paint X 26. Sheaves X

3. Tires/Tracks X 27. Cheek Plates X

4. Sheet Metal X 28. Pins X

5. Glass X 29. Swivel X

6. Guards in Place X 30. Hook X

7. Horn X 31. Hoist Rope Retainer X

8. Footwalk & Handrail X 32. Sheave Bearings X

9. CAB 33. Anchoring of Rope X

10. Fire Extinguisher X 34. Hook Safety Latches X

11. Load Rating Chart X 35. Latch can be used for man-lifting X

12. Controls Identified X 36. Rope reeving X

13. Level Indicator X 37. Pins/Keepers X

14. Load Indicator X 38. Grapple Condition X

15. Caution & Warning Signs

X 39.

16. Operators Manual X 40.

17. Hand Signal Chart X 41. BOOM

18. Gauges X 42. Point Sheaves X

19. Required Controls X 43. Anchoring of rope X

20. Controls Identified X 44. Sheave bearings X

21. Remote Control X 45. Tip section X

22. 46. Intermediate Section X

23. 46. Base section X

24. 48. Anti–Two Blocking System X

25. 49. Anti-Two Blocking System can be used for man-lifting X

26. 50. Roller/Wear Pads X

51. Boom Extension hose & reel X

52. Hinge Pin X NOTES:______________________________________________________________________________

4 CRANE INSPECTION SERVICES, INC.

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

CODE: 1563-100 DATE: 01/23/23

N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U

BOOM (Cont.) 78. WINCH MOTOR

53. Hoist cylinders X 79. Wire rope cond. X

54. Hyd. hose & fittings X 80. Mounting Bolts X

55. Angle/Radius Indicator X 81. Rope Anchoring X

56. Boom ext. cyl. X 82. Rope spooling X

57. 83. Brakes X

58. 84. Drum Speed Indicator X

59. 85. Hyd Hose & Fittings X

60. 86.

61. 87.

62. 88.

63. 89.

64. 90.

65. 91.

66. 92.

67. 93.

68. 94.

69. 95.

70. 96.

71 . 97.

72 . 98.

73. 99.

74. 100.

75. 101.

76. 102.

77. 103.

NOTES:______________________________________________________________________________

5 CRANE INSPECTION SERVICES, INC.

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

CODE: 1563-100 DATE: 01/23/23

N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U

104. TURNTABLE 124. CHASSIS

105. Rotex X 125. Back-Up/Motion alarm X

106. Structure X 126. Suspension X

107. Mounting Bolts X 127. Hyd. Hose & Fittings X

108. Swing pinion gear X 128. Air system X

109. Swing bull gear X 129. Parking brakes X

110. Hyd. hose & fittings X 130. Travel foot brakes X

111. Swing brake X 131. Electrical System X

112. House lock X 132. Steering X

113. 133. Rear wheel steering sys. X

114. 134. Mounting Bolts X

115. 135. Exhaust System X

116. COUNTERWEIGHT 136. Generator X

117. Correct Size X 137. Transmission X

118. Mounting Bolts X 138.

119. Warning Signs X 139.

120. 140.

121. 141.

122. 142.

123. 143.

NOTES:______________________________________________________________________________

6 CRANE INSPECTION SERVICES, INC.

Office (251)928-6262 • Fax (251)990-6133

N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U

144. OUTRIGGERS 152. TRACKS

145. Horizontal Cyl. & Hoses X 153. Pads X

146. Vertical Cyl & Hoses X 154. Rollers X

147. Beams X 155. Idler Wheels X

148. Boxes X 156. Drive Wheels X

149. Floats X

150. Pins & Keepers X

151. Holding Valves X

7 CRANE INSPECTION SERVICES, INC.

NOTICE OF DEFICIENCIES AND/OR RECOMMENDATIONS

The following deficiencies, prefixed with the letter *(D), require proper corrective action prior to issuance of a certificate. *(deficiencies must be corrected within 30 days of the inspection, otherwise re-inspection of the unit will be required to verify corrective action has been completed). Indicate date corrective action completed. Sign on the bottom and E-Mail to Crane Inspection Services, Inc. at tflynnp@aol.com.

Items prefixed with the letter *(R) are recommendations to improve equipment utilization and safety. Mandatory correction is not required for certification but highly recommended.

* Not required in some states. But corrective action needs to be take

Description of Condition to be Corrected

Regulation number(s) that apply NOTE: Quotes of the Standards on request only

Verification of Correction Date/ Signature

D1) The Anti-Two block system is not working and needs to be repaired.

OSHA 1910,1926, ANSI B30.5

Suggestion

8 CRANE INSPECTION SERVICES, INC.

9 CRANE INSPECTION SERVICES, INC.

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

SUPPLEMENT "A"

Crane Inspection Services, Inc. offers inspection services in the following areas:

- periodic OSHA compliance inspections of all shore-based cranes including, but not limited to, mobile cranes, overhead cranes, derricks, and wire rope systems

- monthly cable inspections for compliance with OSHA regulations

- review of inspection and maintenance records as to compliance with federal regulations

- physical inspections utilizing worksheets, inspection forms, and photographs

- Crane Inspection Services, Inc. is a past accredited agency by the state of California.

- Crane Inspection Services, Inc. is a recognized private agency, accredited by the U.S. Department of Labor under 29 CFR Part 1919, to inspect, test, and issue documents/papers of certification where required on shore-based material handling devices, without limitation, and floating cranes and derricks under the OSHA Maritime Safety Regulations 29 CFR Parts 1915 (shipyards), 1917 (marine terminals), and 1918 (longshoring).

Additional services offered:

- Crane Operating Training Seminar for R/T Cranes, or Mobile Cranes and Overhead Cranes

- Operator Training Seminar for Powered Industrial Trucks (Forklifts)

- James Pritchett is accredited by OSHA to teach courses in Construction Safety and Health Regulations

- accident investigations for owners, users, insurance companies and other entities including accident site inspections, photographs, interviews, and collection of pertinent data.

- reconstruction of crane accidents in an effort to determine cause and effect.

- evaluation of equipment to be purchased with reference to anticipated use.

Crane Inspection Services, Inc. is proud to include the following distinctions:

- James Pritchett is accredited by OSHA to teach courses in Construction Safety and Health Regulations

- James Pritchett is a past instructor for the U.S. Department of Labor and provide training for their compliance officers on the techniques of crane inspection.

- James Pritchett is one of a small number of delegates from the United States of America to the Technical Advisory Group (TAG) within ISO, Technical Committee for Cranes TC96. This committee meets with other international safety delegates to discuss the formulation of crane safety guidelines.

- James Pritchett is Past President of the Crane Certification Association of America (CCAA). This is a national association that is made up of the 118 agencies nationwide.

- James Pritchett is a member of The Society of Naval Architects and Marine Engineers.

10 CRANE INSPECTION SERVICES, INC.

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

SUPPLEMENT "B"

APPLICABLE TO CRANE INSPECTION SERVICES, INC.

INSPECTION REPORTS

Inspection reports are based upon observed procedures and inspections performed by Crane Inspection Services, Inc.

representatives, but are not intended to replace or supersede the necessity for routine or preventative maintenance or procedures recommended by others, such as, but not limited to manufacturers, operators, and other inspecting organizations or persons.

Referral to applicable regulations is essential with regard to responsibilities of owners and users for use, maintenance, and normal operational inspections. It is especially important that owners and users, regularly and by means of extraordinary disassembly and/or non-destructive testing, arrange to effectively examine parts of the equipment which may be reasonably accessible by routine examinations, including such examinations by Crane Inspection Services, Inc. representatives.

Equipment owners and users should assure continuous compliance with all manufacturer, regulatory, and other applicable performance specifications, including but not limited to, full range accuracy of load indicating devices, machinery, etc., regardless of the extent to which specifications can be evaluated during Crane Inspection Services, Inc.'s inspections.

Other requirements of applicable Federal and State regulations not specifically considered within the scope or recorded by related Crane Inspection Services, Inc.'s reports, remain for the continuing attention and responsibility of equipment owners and users, including but not limited to, adequate lighting, walkways, ladders, stairways, clearance between moving and fixed structures, electrical motor restart lockouts, fire extinguishers in the vicinity, etc.

Crane Inspection Services, Inc. will provide, upon reasonable request, a Representative to witness tests of equipment as conducted and/or arranged by such company or person, and to complete related inspections in accordance with applicable regulations and standards to facilitate the issue of associated certificates which will be processed and provided by Crane Inspection Services, Inc., P. O. Box 461, Fairhope, AL 36533-0461.

No terms or conditions contained in any acceptance or acknowledgment regarding Crane Inspection Services, Inc. shall be effective against or binding upon or shall otherwise make Crane Inspection Services, Inc. liable, upon any obligation or upon any theory of breach of warranty, express or applied in law or for any obligation, warranty, guaranty, or other undertaking, unless expressly agreed to in writing by an instrument signed by an authorized officer of Crane Inspection Services, Inc.

Unless otherwise specifically provided for by associated Crane Inspection Services, Inc.'s documents, forms, diagrams, or correspondence, Crane Inspection Services, Inc.'s approval of the working capability of equipment certified or documented is restricted to the certification or documentation of the capability demonstrated and attested to by the specific tests to and inspections of such equipment accomplished in accordance with corresponding standards and requirements for such tests and inspections as established by applicable prevailing Regulations, and consistent with the rated lifting capacity of such equipment as previously documented by other recognized organizations and/or authorities.

11 CRANE INSPECTION SERVICES, INC.

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

GENERAL TERMS AND CONDITIONS

SUPPLEMENT "C"

Crane Inspection Services, Inc. assumes no responsibility for any damages caused by equipment tests arranged by or with the permission of the Owners of the equipment, nor does Crane Inspection Services, Inc. assume responsibility for testing devices and/or weights provided by or with the permission of the Owners of such equipment. Owners of equipment certified or documented by Crane Inspection Services, Inc. should arrange to demonstrate for Crane Inspection Services, Inc.

documentation and/or otherwise maintain a record of and present to Crane Inspection Services, Inc. verification as to the certified accuracy of testing devices and/or certified weights of test loads utilized in connection with related Crane Inspection Services, Inc.'s certifications and documentations.

All equipment should be rigged and employed in an approved and safe manner consistent with corresponding manufacturer specifications and associated certifications and documentations. Crane Inspection Services, Inc. assumes no responsibility for maintenance or proper use or possible misuse of such equipment, and equipment is certified or documented by Crane Inspection Services, Inc. as being in apparent satisfactory condition only to the extent determined by the tests witnessed and the physical examinations reasonably completed. Additionally, it is the responsibility of the user and/or the Owner of the equipment to assure proper use of and to service, repair, or replace the equipment or the components of the equipment as necessary, consistent with any associated Crane Inspection Services, Inc. recommendations and/or occurring conditions in order to insure the continued satisfactory condition of the equipment subsequent to the effective date of and within the intent of the associated Crane Inspection Services, Inc.'s certificate(s) and documentation(s) issued.

Crane Inspection Services, Inc.'s certifications and documentations do not include certification, documentation, or any other approval for or relating to the stability of, means of attachment to, or structural suitability of working surfaces, platforms, piers, vessels, or the like upon which Crane Inspection Services, Inc. inspected equipment may be located or to which Crane Inspection Services, Inc.'s inspected equipment may be attached and placed in service, as such matters of stability, attachment, and structural suitability are not within the intended or the offered scope of Crane Inspection Services, Inc.'s jurisdiction or services.

Resolution of disputes:

The parties agree that this contract was negotiated from the State of Alabama and that final acceptance by Crane Inspection Services, Inc. occurred in Alabama. All disputes and controversies of every kind and nature between arising out of or in connection with this agreement as to the construction, validity, interpretation, meaning, performance or non-performance, enforcement, operation, breach, continuance, or termination thereof or manner and scope of services performed by Crane Inspection Services, Inc. or payment for such services by customer shall be resolved pursuant to the laws of Alabama. The parties consent for all such purposes to personal and subject matter jurisdiction of the courts of Alabama and to venue in Baldwin County, Alabama. This provision shall survive the termination or expiration of this agreement.

Attorney Fees:

In the event Crane Inspection Services, Inc. deems it advisable to engage the services of an attorney for resolution of dispute, Crane Inspection Services, Inc. shall be entitled to recover from Customer a reasonable attorney fee and all other expenses incurred in resolution of the dispute, including without limitation court filling fees, other court costs or arbitration coast, deposition expense of counsel and Crane inspection Services, Inc. personnel, all of which accrue interest at the rate of 1% (one percent) per month until paid. This provision shall survive the termination or expiration of this agreement.

THE ISSUANCE OF A PURCHASE ORDER NUMBER AND/OR VERBAL AUTHORIZATION IS

CONSIDERED ACCEPTANCE OF THE TERMS OF THIS PROPOSAL.

Certificate No. 1563-101 ANNUAL

Pascagoula, MS 39567

Crane (describe type (truck, rail, etc.)) Vessel Mounted (a) Remains at worksite If (a) or (c), describe:

Derrick (describe) Forward Deck Crane - (b) Changes Worksite Mounted on the Ship

If spout or other device, Forward Deck

Manufacturer Aurora Model 30TSC3000 Serial No. 97023-082897

Owner’s Identification, if any OREGON II (Forward Deck Crane)

Lifting Magnet Max SWL 1,800 @ 30FT.

30 ft. 2,340 lb. 1,800 lb.

XXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXX

Means of application of proof load: Scaled Water Weights Basis for assigned load ratings: Posted Rating

I certify that on the 23rd day of January, 2023, the above described device was (tested and examined) by the undersigned or his authorized representative, that said (test and examination) met in all respects with the requirements of the Division of Occupational Safety and Health as per OSHA 1910, 1926, & ANSI. Any deficiencies considered to constitute an unsatisfactory conditions have/been corrected; and that the device has

Name and address of accredited or otherwise authorized organization making the test and/or examination:

Name and address of authorized person carrying out the test and/or examination: Position of signatory in the organization making the Flynn Pritchett test and/or examination:

Crane Inspection Services, Inc. Surveyor

Inspection reports are based upon observed procedures and inspections performed by Crane Inspection Services, Inc. representatives, but are not intended to replace or supersede the necessity for routine or preventative maintenance or procedures recommended by others, such as, but not limited to manufacturers, operators, and other inspecting organizations or persons.

Referral to applicable regulations is essential with regard to responsibilities of owners and users for use, maintenance, and normal operational inspections. It is especially important that owners and users, regularly and by means of extraordinary disassembly and/or non-destructive testing, arrange to effectively examine parts of the equipment which may be reasonably accessible by routine examinations, including such examinations by Crane Inspection Services, Inc. representatives.

Equipment owners and users should assure continuous compliance with all manufacturer, regulatory, and other applicable performance specifications, including but not limited to, full range accuracy of load indicating devices, machinery, etc., regardless of the extent to which specifications can be evaluated during Crane Inspection Services, Inc.'s inspections.

Other requirements of applicable Federal and State regulations not specifically considered within the scope or recorded by related Crane Inspection Services, Inc.'s reports, remain for the continuing attention and responsibility of equipment owners and users, including but not limited to, adequate lighting, walkways, ladders, stairways, clearance between moving and fixed structures, electrical motor restart lockouts, fire extinguishers in the vicinity, etc.

Crane Inspection Services, Inc. will provide, upon reasonable request, a Representative to witness tests of equipment as conducted and/or arranged by such company or person, and to complete related inspections in accordance with applicable regulations and standards to facilitate the issue of associated certificates which will be processed and provided by Crane Inspection Services, Inc., P. O. Box 461, Fairhope, AL 36533-0461.

No terms or conditions contained in any acceptance or acknowledgment regarding Crane Inspection Services, Inc. shall be effective against or binding upon or shall otherwise make Crane Inspection Services, Inc. liable, upon any obligation or upon any theory of breach of warranty, express or applied in law or for any obligation, warranty, guaranty, or other undertaking, unless expressly agreed to in writing by an instrument signed by an authorized officer of Crane Inspection Services, Inc.

Unless otherwise specifically provided for by associated Crane Inspection Services, Inc.'s documents, forms, diagrams, or correspondence, Crane Inspection Services, Inc.'s approval of the working capability of equipment certified or documented is restricted to the certification or documentation of the capability demonstrated and attested to by the specific tests to and inspections of such equipment accomplished in accordance with corresponding standards and requirements for such tests and inspections as established by applicable prevailing Regulations, and consistent with the rated lifting capacity of such equipment as previously documented by other recognized organizations and/or authorities.

Crane Inspection Services, Inc. assumes no responsibility for any damages caused by equipment tests arranged by or with the permission of the Owners of the equipment, nor does Crane Inspection Services, Inc. assume responsibility for testing devices and/or weights provided by or with the permission of the Owners of such equipment. Owners of equipment certified or documented by Crane Inspection Services, Inc. should arrange to demonstrate for Crane Inspection Services, Inc.

documentation and/or otherwise maintain a record of and present to Crane Inspection Services, Inc. verification as to the certified accuracy of testing devices and/or certified weights of test loads utilized in connection with related Crane Inspection Services, Inc.'s certifications and documentations.

All equipment should be rigged and employed in an approved and safe manner consistent with corresponding manufacturer specifications and associated certifications and documentations. Crane Inspection Services, Inc. assumes no responsibility for maintenance or proper use or possible misuse of such equipment, and equipment is certified or documented by Crane Inspection Services, Inc. as being in apparent satisfactory condition only to the extent determined by the tests witnessed and the physical examinations reasonably completed. Additionally, it is the responsibility of the user and/or the Owner of the equipment to assure proper use of and to service, repair, or replace the equipment or the components of the equipment as necessary, consistent with any associated Crane Inspection Services, Inc. recommendations and/or occurring conditions in order to insure the continued satisfactory condition of the equipment subsequent to the effective date of and within the intent of the

Crane Inspection Services, Inc.'s certifications and documentations do not include certification, documentation, or any other approval for or relating to the stability of, means of attachment to, or structural suitability of working surfaces, platforms, piers, vessels, or the like upon which Crane Inspection Services, Inc. inspected equipment may be located or to which Crane Inspection Services, Inc.'s inspected equipment may be attached and placed in service, as such matters of stability, attachment, and structural suitability are not within the intended or the offered scope of Crane Inspection Services, Inc.'s jurisdiction or services.

Office (251)928-6262 • Fax (251)990-6133

CODE: 1563-101 DATE: 01/23/23

TELEPHONE: __(251) 622-1266__________________

SITE CONTACT: ___Mr. Mark Langner__________________________ SURVEYOR: __Mr. Flynn Pritchett_______________________________ INITIAL INSPECTION (YES/NO): _____ RE-INSPECTION (YES/NO):__Yes____ DATE, AGENCY & NUMBER OF LAST LOAD TEST:_Marine Industrial 2021 DATE, AGENCY & NUMBER OF LAST ANNUAL INSP.:Marine Industrial 2021_

PURPOSE OF SURVEY QUAD:____ ANNUAL:_X__ SPECIAL:____

JURISDICTION 1910:__X_ 1926:__X___ ANSI STANDARD:__B30.22 & B30.5

OTHER:_______________________________

DECRIPTION OF CRANE:_ Telescopic Boom Crane Mounted on Vessel – Oregon II_______ MANUFACTURER: ___Aurora_____ MODEL#__30TSC3000_________ S/N__97023-082897___________ MAX CAPACITY__1,800 lb @ 30 Ft.______ OWNER IDENTIFICATION:____Oregon II Forward Telescopic Boom Crane_______________

SERVICE STATUS: LIFTING:_X___ CLAMSHELL: ____

MAGNET:____OTHER:__Hook

DESCRIPTION OF PROOF LOAD:__Scaled Water Weights_________

BASIS FOR ASSIGNED LOAD RATINGS: __STABILITY RATING CHART __________

OTHER:_____________________________________________________________________________

BOOM DIRECTION

30ft 2340 lb. 1,800 lb. N/A REAR

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

CODE: 1563-101 DATE: 01/23/23

ANNUAL CHECKSHEET:

BOOM INFORMATION

1. Boom:

Manufactures Designation _______N/A_________ Sections Identified ___2_____

Boom Length: Min.___17_ Ft. Max. __30_____ Ft.

Draw Sketch of Number and Length of Boom Sections:

Cords: Angular __N/A___ Tubular ___N/A___ Other ____X_______

Lacings: Angular __N/A___ Tubular ___N/A___ Other ____N/A_____

2. Jib:

Manufactures Designation _______N/A_________ Sections Identified ____N/A____

Jib Length: _ N/A _ Ft.

Draw Sketch of Number and Length of Jib Sections:

Cords: Angular __N/A___ Tubular __N/A____ Other ____N/A_____

Lacings: Angular __N/A___ Tubular __N/A____ Other ____N/A_____

Type of jib stops ___N/A________________________________________

HOOK INFORMATION

TRAM: _4 ¼” HOOK: _2 ¾” HOOK INSPECTION:_OK

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

CODE: 1563-101 DATE: 01/23/23

N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U

1. GENERAL

APPEARANCE

25. LOAD BLOCK/GRAPPLE

2. Paint X 26. Sheaves X

3. Tires/Tracks X 27. Cheek Plates X

4. Sheet Metal X 28. Pins X

5. Glass X 29. Swivel X

6. Guards in Place X 30. Hook X

7. Horn X 31. Hoist Rope Retainer X

8. Footwalk & Handrail X 32. Sheave Bearings X

9. CAB 33. Anchoring of Rope X

10. Fire Extinguisher X 34. Hook Safety Latches X

11. Load Rating Chart X 35. Latch can be used for man-lifting X

12. Controls Identified X 36. Rope reeving X

13. Level Indicator X 37. Pins/Keepers X

14. Load Indicator X 38. Grapple Condition X

15. Caution & Warning Signs

X 39.

16. Operators Manual X 40.

17. Hand Signal Chart X 41. BOOM

18. Gauges X 42. Point Sheaves X

19. Required Controls X 43. Anchoring of rope X

20. Controls Identified X 44. Sheave bearings X

21. Remote Control X 45. Tip section X

22. 46. Intermediate Section X

23. 46. Base section X

24. 48. Anti–Two Blocking System X

25. 49. Anti-Two Blocking System can be used for man-lifting X

26. 50. Roller/Wear Pads X

51. Boom Extension hose & reel X

52. Hinge Pin X

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

CODE: 1563-101 DATE: 01/23/23

N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U

BOOM (Cont.) 78. WINCH MOTOR

53. Hoist cylinders X 79. Wire rope cond. X

54. Hyd. hose & fittings X 80. Mounting Bolts X

55. Angle/Radius Indicator X 81. Rope Anchoring X

56. Boom ext. cyl. X 82. Rope spooling X

57. 83. Brakes X

58. 84. Drum Speed Indicator X

59. 85. Hyd Hose & Fittings X

60. 86.

61. 87.

62. 88.

63. 89.

64. 90.

65. 91.

66. 92.

67. 93.

68. 94.

69. 95.

70. 96.

71 . 97.

72 . 98.

73. 99.

74. 100.

75. 101.

76. 102.

77. 103.

NOTES:______________________________________________________________________________

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

CODE: 1563-101 DATE: 01/23/23

N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U

104. TURNTABLE 124. CHASSIS

105. Rotex X 125. Back-Up/Motion alarm X

106. Structure X 126. Suspension X

107. Mounting Bolts X 127. Hyd. Hose & Fittings X

108. Swing pinion gear X 128. Air system X

109. Swing bull gear X 129. Parking brakes X

110. Hyd. hose & fittings X 130. Travel foot brakes X

111. Swing brake X 131. Electrical System X

112. House lock X 132. Steering X

113. 133. Rear wheel steering sys. X

114. 134. Mounting Bolts X

115. 135. Exhaust System X

116. COUNTERWEIGHT 136. Generator X

117. Correct Size X 137. Transmission X

118. Mounting Bolts X 138.

119. Warning Signs X 139.

120. 140.

121. 141.

122. 142.

123. 143.

NOTES:______________________________________________________________________________

Office (251)928-6262 • Fax (251)990-6133

U = UNSATISFACTORY

N/A S U N/A= NON APPICABLE

S = SATISFACTORY

U = UNSATISFACTORY

N/A S U

144. OUTRIGGERS 152. TRACKS

145. Horizontal Cyl. & Hoses X 153. Pads X

146. Vertical Cyl & Hoses X 154. Rollers X

147. Beams X 155. Idler Wheels X

148. Boxes X 156. Drive Wheels X

149. Floats X

The following deficiencies, prefixed with the letter *(D), require proper corrective action prior to issuance of a certificate. *(deficiencies must be corrected within 30 days of the inspection, otherwise re-inspection of the unit will be required to verify corrective action has been completed). Indicate date corrective action completed. Sign on the bottom and E-Mail to Crane Inspection Services, Inc. at tflynnp@aol.com.

Items prefixed with the letter *(R) are recommendations to improve equipment utilization and safety. Mandatory correction is not required for certification but highly recommended.

* Not required in some states. But corrective action needs to be take

Description of Condition to be Corrected

Regulation number(s) that apply NOTE: Quotes of the Standards on request only

Verification of Correction Date/ Signature

OSHA 1910,1926, ANSI B30.5

D1) The Anti-Two Block system is not working and needs to be repaired.

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

SUPPLEMENT "A"

Crane Inspection Services, Inc. offers inspection services in the following areas:

- periodic OSHA compliance inspections of all shore-based cranes including, but not limited to, mobile cranes, overhead cranes, derricks, and wire rope systems

- monthly cable inspections for compliance with OSHA regulations

- review of inspection and maintenance records as to compliance with federal regulations

- physical inspections utilizing worksheets, inspection forms, and photographs

- Crane Inspection Services, Inc. is a past accredited agency by the state of California.

- Crane Inspection Services, Inc. is a recognized private agency, accredited by the U.S. Department of Labor under 29 CFR Part 1919, to inspect, test, and issue documents/papers of certification where required on shore-based material handling devices, without limitation, and floating cranes and derricks under the OSHA Maritime Safety Regulations 29 CFR Parts 1915 (shipyards), 1917 (marine terminals), and 1918 (longshoring).

Additional services offered:

- Crane Operating Training Seminar for R/T Cranes, or Mobile Cranes and Overhead Cranes

- Operator Training Seminar for Powered Industrial Trucks (Forklifts)

- James Pritchett is accredited by OSHA to teach courses in Construction Safety and Health Regulations

- accident investigations for owners, users, insurance companies and other entities including accident site inspections, photographs, interviews, and collection of pertinent data.

- reconstruction of crane accidents in an effort to determine cause and effect.

- evaluation of equipment to be purchased with reference to anticipated use.

Crane Inspection Services, Inc. is proud to include the following distinctions:

- James Pritchett is accredited by OSHA to teach courses in Construction Safety and Health Regulations

- James Pritchett is a past instructor for the U.S. Department of Labor and provide training for their compliance officers on the techniques of crane inspection.

- James Pritchett is one of a small number of delegates from the United States of America to the Technical Advisory Group (TAG) within ISO, Technical Committee for Cranes TC96. This committee meets with other international safety delegates to discuss the formulation of crane safety guidelines.

- James Pritchett is Past President of the Crane Certification Association of America (CCAA). This is a national

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

SUPPLEMENT "B"

Inspection reports are based upon observed procedures and inspections performed by Crane Inspection Services, Inc.

representatives, but are not intended to replace or supersede the necessity for routine or preventative maintenance or procedures recommended by others, such as, but not limited to manufacturers, operators, and other inspecting organizations or persons.

Referral to applicable regulations is essential with regard to responsibilities of owners and users for use, maintenance, and normal operational inspections. It is especially important that owners and users, regularly and by means of extraordinary disassembly and/or non-destructive testing, arrange to effectively examine parts of the equipment which may be reasonably accessible by routine examinations, including such examinations by Crane Inspection Services, Inc. representatives.

Equipment owners and users should assure continuous compliance with all manufacturer, regulatory, and other applicable performance specifications, including but not limited to, full range accuracy of load indicating devices, machinery, etc., regardless of the extent to which specifications can be evaluated during Crane Inspection Services, Inc.'s inspections.

Other requirements of applicable Federal and State regulations not specifically considered within the scope or recorded by related Crane Inspection Services, Inc.'s reports, remain for the continuing attention and responsibility of equipment owners and users, including but not limited to, adequate lighting, walkways, ladders, stairways, clearance between moving and fixed structures, electrical motor restart lockouts, fire extinguishers in the vicinity, etc.

Crane Inspection Services, Inc. will provide, upon reasonable request, a Representative to witness tests of equipment as conducted and/or arranged by such company or person, and to complete related inspections in accordance with applicable regulations and standards to facilitate the issue of associated certificates which will be processed and provided by Crane Inspection Services, Inc., P. O. Box 461, Fairhope, AL 36533-0461.

No terms or conditions contained in any acceptance or acknowledgment regarding Crane Inspection Services, Inc. shall be effective against or binding upon or shall otherwise make Crane Inspection Services, Inc. liable, upon any obligation or upon any theory of breach of warranty, express or applied in law or for any obligation, warranty, guaranty, or other undertaking, unless expressly agreed to in writing by an instrument signed by an authorized officer of Crane Inspection Services, Inc.

Unless otherwise specifically provided for by associated Crane Inspection Services, Inc.'s documents, forms, diagrams, or correspondence, Crane Inspection Services, Inc.'s approval of the working capability of equipment certified or documented is restricted to the certification or documentation of the capability demonstrated and attested to by the specific tests to and inspections of such equipment accomplished in accordance with corresponding standards and requirements for such tests and inspections as established by applicable prevailing Regulations, and consistent with the rated lifting capacity of such equipment

11 CRANE INSPECTION SERVICES, INC.

Office (251)928-6262 • Fax (251)990-6133

WWW.CRANEINSPECTION.COM

Crane Inspection Services, Inc. assumes no responsibility for any damages caused by equipment tests arranged by or with the permission of the Owners of the equipment, nor does Crane Inspection Services, Inc. assume responsibility for testing devices and/or weights provided by or with the permission of the Owners of such equipment. Owners of equipment certified or documented by Crane Inspection Services, Inc. should arrange to demonstrate for Crane Inspection Services, Inc.

documentation and/or otherwise maintain a record of and present to Crane Inspection Services, Inc. verification as to the certified accuracy of testing devices and/or certified weights of test loads utilized in connection with related Crane Inspection Services, Inc.'s certifications and documentations.

All equipment should be rigged and employed in an approved and safe manner consistent with corresponding manufacturer specifications and associated certifications and documentations. Crane Inspection Services, Inc. assumes no responsibility for maintenance or proper use or possible misuse of such equipment, and equipment is certified or documented by Crane Inspection Services, Inc. as being in apparent satisfactory condition only to the extent determined by the tests witnessed and the physical examinations reasonably completed. Additionally, it is the responsibility of the user and/or the Owner of the equipment to assure proper use of and to service, repair, or replace the equipment or the components of the equipment as necessary, consistent with any associated Crane Inspection Services, Inc. recommendations and/or occurring conditions in order to insure the continued satisfactory condition of the equipment subsequent to the effective date of and within the intent of the associated Crane Inspection Services, Inc.'s certificate(s) and documentation(s) issued.

Crane Inspection Services, Inc.'s certifications and documentations do not include certification, documentation, or any other approval for or relating to the stability of, means of attachment to, or structural suitability of working surfaces, platforms, piers, vessels, or the like upon which Crane Inspection Services, Inc. inspected equipment may be located or to which Crane Inspection Services, Inc.'s inspected equipment may be attached and placed in service, as such matters of stability, attachment, and structural suitability are not within the intended or the offered scope of Crane Inspection Services, Inc.'s jurisdiction or services.

Resolution of disputes:

The parties agree that this contract was negotiated from the State of Alabama and that final acceptance by Crane Inspection Services, Inc. occurred in Alabama. All disputes and controversies of every kind and nature between arising out of or in connection with this agreement as to the construction, validity, interpretation, meaning, performance or non-performance, enforcement, operation, breach, continuance, or termination thereof or manner and scope of services performed by Crane Inspection Services, Inc. or payment for such services by customer shall be resolved pursuant to the laws of Alabama. The parties consent for all such purposes to personal and subject matter jurisdiction of the courts of Alabama and to venue in Baldwin County, Alabama. This provision shall survive the termination or expiration of this agreement.

Attorney Fees:

In the event Crane Inspection Services, Inc. deems it advisable to engage the services of an attorney for resolution of dispute, Crane Inspection Services, Inc. shall be entitled to recover from Customer a reasonable attorney fee and all other expenses incurred in resolution of the dispute, including without limitation court filling fees, other court costs or arbitration coast, deposition expense of counsel and Crane inspection Services, Inc. personnel, all of which accrue interest at the rate of 1% (one percent) per month until paid. This provision shall survive the termination or expiration of this agreement.

THE ISSUANCE OF A PURCHASE ORDER NUMBER AND/OR VERBAL AUTHORIZATION IS

CONSIDERED ACCEPTANCE OF THE TERMS OF THIS PROPOSAL.

Certificate No. 1563-102 ANNUAL

Pascagoula, MS 39567

Crane (describe type (truck, rail, etc.)) Vessel Mounted (a) Remains at worksite If (a) or (c), describe:

Derrick (describe) J-Frame Lift System (b) Changes Worksite Mounted on the Ship

If spout or other device, Manufacturer J-Frame Model Unknown Serial No. Unknown

Owner’s Identification, if any OREGON II (J-Frame Lifting System)

Lifting Magnet Max SWL 2,800

N/A 2,450 lb. 1,950 lb.

XXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXX

Means of application of proof load: Scaled Water Weights Basis for assigned load ratings: Posted Rating

I certify that on the 23rd day of January, 2023, the above described device was (tested and…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .