This document contains an equipment responsibility matrix and federal contract solicitation. The matrix lists various types of building equipment and systems and identifies whether they are considered standard or above standard building components. It also notes which entities, such as GSA, the lessor, or FDA, are responsible for the equipment's maintenance, repairs, warranties and preventative maintenance. The solicitation seeks a Construction Manager as Constructor contractor to perform repair and alteration work for the FDA Forensic Chemistry Center and Peck Federal Building in Cincinnati, Ohio. The project aims to modernize outdated building systems and expand FDA's laboratory spaces. Offerors must submit proposals by the specified due date to be considered for the award of a Guaranteed Maximum Price contract. Relevant agencies involved include GSA and FDA.
View the file
Other files
Show 40 more
Latest 50 of 95 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FDA Equipment Responsiblity Mat
| FDA Equipment Responsibility Matrix |
| (Insert Location Here) |
| Date Revised: XX/XX/XXXX |
| Equipment | Responsibility | PM Specification / Standards | Frequency | Footnote | ||
| Core/Shell | TI | Repair |
: Is there a threshold?
-Christine Ewing - WPM1C This is a critical point that will depend on the circumstances of the lab location (owned/leased, etc.)
-Nathan Ingersoll - 5P1CAT I agree. A column listing the threshold amount would make it clear based on the particular owned/leased bldg -Christine Ewing - WPM1C Added a column for this - please let me know if what I added makes sense.
-Ron Snow - PCBAB : Define: 1. Who manages this? Regional PM? 2. When do they start filling this out? 3. When does it need to be filled out by?
-Ron Snow - PCBAB : Edit instructions to note further that team must edit standard and above standards items based on type of space and TI and above TI items, etc. Use pricing policy language. Check with Bill Hunt on language before finalizing.
| -Ron Snow - PCBAB | Repair Threshold? | Under Warranty? | Warranty Expiration Date | Preventative Maintanence (PM) | Please Read Prior to Completing: | |||||||
| Standards Items | Yes or No? | Yes or No? | GSA/Lessor/FDA? | Yes or No? If so, list amount. | Yes or No? | xx/xx/xxxx | GSA/Lessor/FDA? | I.E.: ASHRAE Standard 135 | i.e. Monthly | i.e 1 | ||
| 1 | Building Automation Systems (BAS) | Instructions: |
FDA and GSA Project Teams are to edit the equipment lists to the specific project that they are working on. Add/Delete equipment specific to the location as well as all other applicable information for each item. The intent is for the FDA and GSA have a clear understanding and expectation prior to occupancy as well as throughout.
Responsibilty for this Document:
GSA Regional Project Manager is responsible for this matrix during the project lifecycle and shall ensure it is filled out accurately and timely. Once the facility is occupied, it shall be the responsibility of the GSA Facilities Management team to maintain and update.
Timing of Completing this Document:
This document should be filled out as early on in the project planning as possible and updated throughout the life of the project. Once the construction is complete, it should be turned over to the GSA Facilities Management team.
Standard vs. Above Standard (Pricing Policy):
Standard (Core/Shell):
Building shell is the complete enveloping structure, the base building systems, and the finished common areas (building common and floor common) of a building that adjoin the tenant areas. Please see Chapter 2 of the GSA Pricing Desk Guide for a more detailed description.
Above Standard (Tenant Improvements or TI):
TIs are the finishes and fixtures that typically take space from the shell condition to a finished, usable condition. The resulting space is complete, meets applicable building codes, and meets the tenant agency’s functional needs. Please see Chapter 2 of the GSA Pricing Desk Guide for a more detailed description.
| 2 | JACE's |
| 3 | Air Handling Units |
| 4 | VAV Boxes |
| 5 | Fan Coil Units |
| 6 | Permiter Radiation |
| 7 | Hot Water Pumps |
: One of the difficulties we have had at the FCC is that these central systems are sized to meet the mission needs of the FDA lab and therefore much larger than "standard" sizes for a commercial office application. Perhaps we assign Shell/TI percentages for some of these items?
| -Nathan Ingersoll - 5P1CAT | |
| 8 | Chilled Water Pumps |
| 9 | Chillers |
| 10 | Cooling Tower |
| 11 | Switch Gear |
| 12 | Panel Boards |
| 13 | Lighting |
| 14 | Domestic Plumbing |
| 15 | Sanitary Piping |
| 16 | Storm Piping |
| 17 | Fire Alarm |
| 18 | Fire Sprinkler |
| 19 | Elevators |
| 20 | Roof |
| 21 | Exterior Facade |
| 22 | Doors and Windows |
| Above Standard Items | |
| 1 | Special architectural features in GSA controlled public areas |
| 2 | Display cases |
| 3 | Building fire alarm system- including annunicators and announcement components. |
| 4 | All biosafety cabinets & fume hoods including annual certification |
| 5 | Laboratory exhaust systems |
| 6 | Compressed air system (both central & sub-system) |
| 7 | Vacuum system (for FDA equipment) |
| 8 | Reverse osmosis deionizer water system including all sub-systems, controls, & fixtures |
| 9 | Chilled water closed loop (secondary loop) (Bldg 62) |
| 10 | Cold Rooms including all sub-systems, controls, and fixtures |
| 11 | Lab water softener system and sub-systems and water conditioners |
| 12 | UPS systems- Building Life Safety- |
| 13 | Reese system |
| 14 | Public address system- not associated with fire alarm system |
| 15 | AV system including all controls and all sub-systems (controls, fixtures, etc.) |
| 16 | Window blinds and roller shades (Building Std only) |
| 17 | Autoclave and all sub-systems, controls, fixtures, and replacement parts |
| 18 | Safety showers |
| 19 | Emergency eye wash stations |
| 20 | Dishwashers / glass washers |
| 21 | Stand-alone ice makers |
| 22 | Refrigerators including water filtration and ice maker |
| 23 | Freezers & ultra low freezers |
| 24 | Air & water cooled chillers / exchangers water & air |
| 25 | Water purifier / polisher |
| 26 | Glass washing units |
| 27 | Base building air handling units |
| 28 | Variable air volume boxes |
| 29 | Air terminal boxes |
| 30 | HVAC units for special space supplemental HVAC air handling units; data center, computer room and laboratory CRAC units, A/C units for the FDA UPS systems, DX cooling systems, heat exchangers for FDA equipment cooling. |
| 31 | Building reheat system including all controls and all sub-systems, controls, and fixtures |
| 32 | UV lights in base building air handling units |
| 33 | Building plumbing system including all controls and all sub-systems, controls, and fixtures for domestic water and sewer. Potable water. |
| 34 | Building room fan coil units including all controls and all sub-systems, controls, and fixtures |
| 35 | Building room electric heaters including all controls and all sub-systems, controls, and fixtures |
| 36 | Building electrical systems including standard ceiling and wall lights, motion detectors, dimmer lights / switches / sub-systems, and remotes including all controls and fixtures serving base building. |
| 37 | Specialized electrical systems including voltage converters, power suppliers, controllers and specialized lighting fixtures for FDA equipment. Including 60 HZ to 50Hz, 50HZ 230 V power system. |
| 38 | Specialized lighting systems in laboratories and procedure rooms- includes special spectrum, temperature and intensity lights. Std flurorescent ceiling lights are GSA. |
| 39 | Building automation system including all sub-systems, controls, and fixtures |
| 40 | Steam Stations |
| 41 | Boilers including all sub-systems, controls, and replacement parts. |
| 42 | Humidifiers- base building tied into main AHUs |
| 43 | General exhaust systems- pantry and restroom |
| 44 | HEPA filters |
| 45 | Tunnel washer including all associated traps, controls, sub-systems, and replacement parts |
| 46 | Cage washer including all associated traps, controls, sub-systems, and replacement parts |
| 47 | Table top steam sterilizer including all sub-systems, controls, & replacement parts |
| 48 | Automatic animal drinking water system |
| 49 | Facility access panels throughout hallways and inside rooms |
| 50 | Automatic doors |
| 51 | Roll up doors at loading docks incl. controls and fixtures |
| 52 | Dock levelers |
| 53 | Chemical feed system associated with above standard equipment |
| 54 | Hose system, hot water mixing station for domestic water |
| 55 | Gantries, monorails, unistruct support rails in laboratories |
| 56 | Skylights |
| 57 | Prefab rooms |
| 58 | Anechoic chambers & accessories (4) in G101 including grounding, shielding, electronic, electrical, mechanical, pneumatic systems, air compress or absorption replacement, re-calibrating, and general maintenance. Includes specialized fire alrm system and suspression system. |
| 59 | RF Shielding |
| 60 | Degassed water system including all sub-systems, controls, fixtures, and high purified 99.995% nitrogen |
| 61 | Antenna systems - external and internal including towers, antennas, cabling, rotors, grounding, controls and other assocaited components used by FDA. |
| 62 | Instant hot and under counter water heaters for pantries and restrooms |
| 63 | Garbage disposals in pantries |
| 64 | Waste treatment equipment for labs or vivarium |
| 65 | FDA owned portable air conditioning units and spot coolers |
| 66 | Package AC units in MPOP rooms |
| 67 | Package AC units and heat pumps in Child Care Center |
| 68 | Vibration isolation floors and tables |
| 69 | Phoenix control systems including fixtures and controls for spaces |
| 70 | Phoenix controls for anteroom alarm and interlock systems |
| 71 | DI and watering system |
| 72 | Plate and frame heat exchangers- Building HVAC system only |
| 73 | Enthalpy wheels- Building HVAC system only |
| 74 | Hot and chilled water system filters in primary loop |
| 75 | Communciation systems including subsystems, controls, and fixtures including Wifi, cellular repeaters and amplifiers |
| 76 | Batteries: wet cell / lead acid batteries for Data Center and agency UPS |
| 77 | Battery monitoring systems for Data Center |
| 78 | Bedding machine and dumpster service |
| 79 | Down draft table |
| 80 | Microscope chiller |
| 81 | Liquid nitrogen systems including subsystems, controls and fixtures |
| 82 | Site Scan system (data center) |
| 83 | Sterlizers |
| 84 | Airquity system |
| 85 | Rotary UPS |
| 86 | Bubble dampers |
| 87 | Security equipment including maglocks, card readers and electroninc security equipment including exterior call stations. |
| 88 | Door locks and keys |
| 89 | Electric or hydraulic vehicle control devices incl. security lift gates, bollards, traffic signal lights |
| 90 | Insect control devices in labs |
| 91 | Foundation distribution cabinet (power for Data center) |
| 92 | Power distribution system to CSU Data Center |
| 93 | Furniture task lighting |
| 94 | Site lighting along sidewalks, roads and parking lots |
| 95 | Art In Architecture - interior and exterior |
| 96 | Interior plants in lobbies and atriums |
| 97 | Playground Equipment |
| 98 | North Garage UPS |
| 99 | Emergency Generators within the Central Utility Plant |
| 100 | Emergency Generators (EGEN) outisde of the Central Utility Plant |
| 101 | Special wall, floor or ceiling finishes in labs and vivarium |
| General Notes | |
| A | Example: PM and repairs by GSA will be provided by the O&M contractor or a specialized vendor |
| B | |
| C | |
| D | |
| Footnotes | |
| 1 | Example: The base building Building Automation System (BAS) is maintained by GSA- Systems such as the AirQuity, animal drinking water system, "Watch Dog" , or Phoenix door interlock and access control systems are the responsibility of FDA. |
| 2 | |
| 3 | |
| 4 | |
| 5 | |
| 6 | |
| 7 | |
| 8 | |
| 9 | |
| 10 | |
| 11 | |
| 12 | |
| 13 | |
| 14 | |
| 15 | |
| 16 | |
| 17 | |
| 18 | |
| 19 | |
| 20 |
&F &P
File details come from the government source that posted it. Updated .