Appendix-C-DepartmentalDrawings.pdf
PDF 13 MB Posted
- Solicitation number
- 47PF0020R0057S
About this file
This document provides details for a solicitation to award a Construction Manager as Constructor contract for modernization and expansion projects at two federal buildings in Cincinnati, Ohio. The General Services Administration intends to award a Guaranteed Maximum Price contract to provide construction management services for repair, alteration and laboratory expansion projects at the FDA Forensic Chemistry Center and Peck Federal Building. The proposed work will update outdated building systems and expand FDA laboratory spaces to meet long-term agency needs. Interested parties should review the attached solicitation document for additional requirement details such as response dates and agency points of contact.
View the file
Other files
Show 40 more
Latest 50 of 95 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOLS LEGEND
Sheet Number
A-100 Sheet Number
Discipline Code
View Title
A1 View Name 1/8" = 1'-0"
Drawing Scale
Drawing Number
North Arrow
Plan North
Graphic Scale 0 2' 4' 8'
True North
CL
Centerline Denotes Centerline of an Object
12" = 1'-0"
05/21/2020
CONCEPT DESIGN_APPENDIX C - DEPARTMENTAL DRAWINGS
G-00
FORENSIC CHEMISTRY CENTER | FDA
FIELDS WITH "●" INDICATE SHEET ISSUED AS PART OF THE
CORRESPONDING ISSUANCE PACKAGE. BLANK FIELDS INDICATE...
G-001s - Drawing Index-APPENDIX C
Sheet Number Sheet Name
Mechanical
M-1 FIRST FLOOR DEMOLITION PLAN
M-2 ROOF DEMOLITION PLAN
M-3 FIRST FLOOR MECHANICAL PLAN
M-4 ROOF MECHANICAL PLAN
M-5 CHILLED WATER OPTION #1
M-6 CHILLED WATER OPTION #2
M-7 PREFERRED OPTION-CHILLED WATER OPTION 3
M-8 HOT WATER OPTIONS
M-9 STEAM BOILER OPTIONS
M-10 NEW AHU AIRFLOW DIAGRAM
M-11 NEW EXHAUST FAN AIRLFOW DIAGRAM
M-12 HEATING HOT WATER DIAGRAM
M-13 CHILLED WATER DIAGRAM
M-14 ISOMETRIC ROOF OPTIONS
M-15 ISOMETRIC BASMENT OPTIONS
M-16 ISOMETRIC ROOF MECHANICAL ROOM OPTIONS
M-17 MECHANICAL SCHEDULES
M-18 MECHANICAL SCHEDULES
FIELDS WITH "●" INDICATE SHEET ISSUED AS PART OF THE
CORRESPONDING ISSUANCE PACKAGE. BLANK FIELDS INDICATE...
G-001s - Drawing Index-APPENDIX C
Sheet Number Sheet Name
01-GENERAL
G-00 CONCEPT DESIGN_APPENDIX C -
DEPARTMENTAL DRAWINGS
G-01 CODE PLAN - OPTION 1
G-02 CODE PLAN - OPTION 2
G-03 CODE PLAN - OPTION 3
G-04 CODE PLAN - SELECTED OPTION
08-ARCHITECTURAL
AD-01 DEMOLITION/RENOVATION PLAN - FIRST FLOOR
A-01 GARAGE FLR PLAN - EXIST SPACE USE
DIAGRAM
A-02 1ST FLOOR PLAN - EXIST SPACE USE DIAGRAM
A-03 ROOF PLAN - EXISTING
A-10 CONCEPT PLAN - FIRST FLOOR - OPTION 1
A-11 CONCEPT PLAN - FIRST FLOOR - OPTION 2
A-12 CONCEPT PLAN - FIRST FLOOR - OPTION 3
A-13 SELECTED CONCEPTUAL DESIGN OPTION
A-20 PHASING PLAN - FIRST FLOOR - OPTION 1
A-21 PHASING PLAN - FIRST FLOOR -OPTION 2
A-22 PHASING PLAN - FIRST FLOOR - OPTION 3
A-30 ROOM STYLE SCHEDULE
10-EQUIPMENT
Q-01 LABORATORY LAYOUT - OPTION 1 - PREFERRED
Q-02 LABORATORY LAYOUT - OPTION 2
Q-03 LABORATORY LAYOUT - OPTION 3
Q-04 LABORATORY CASEWORK LAYOUT - OPTION 1 -
PREFERRED
Q-05 LABORATORY CASEWORK LAYOUT - OPTION 2
Q-06 LABORATORY CASEWORK LAYOUT - OPTION 3
Q-07 LABORATORY CASEWORK - 3D VIEW - OPTION 1
Q-08 LABORATORY CASEWORK - 3D VIEW - OPTION 2
797.71 SF
Group A-3
Load Factor:15 Calc Occ: 53
Area
Assembly
58783.32 SF
Group B
Load Factor:150
Calc Occ: 392
Area
Business
272.8 SF
Group B
Load Factor:30 Calc Occ: 9
Area
Business
276.15 SF
Group B
Load Factor:30 Calc Occ: 9
Area
Business
240.78 SF
Group B
Load Factor:30 Calc Occ: 8
Area
Business
413.33 SF
Group B
Load Factor:30 Calc Occ: 14
Area
Business
1362.88 SF
Group A-3
Load Factor:15
Calc Occ: 91
Area
Assembly
1394.74 SF
Group A-3
Load Factor:15
Calc Occ: 93
Area
Assembly
1140.66 SF
Group B
Area
Load Factor:500
Calc Occ: 2
Storage
COMMON PATH
92'-5"92'-5"
TRAVEL DISTANCE
273'-4"
BUSINESS
OCC. LOAD FACTOR: 15
ASSEMBLY
STORAGE
OCCUPANCY LEGEND
BUSINESS
OCC. LOAD FACTOR: 30
BUSINESS
OCC. LOAD FACTOR: 150
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:5
1:
P M
CODE PLAN - OPTION 1
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
G-01
06/11/20
Group S-2 Storage 500 2
Group A-3 Assembly 15 237
Group B Business 150 392
Group B Business 30 40
FIRST FLOOR PLAN
Use Designation Occupancy Classification Occupancy Load Factor Occupant Load
MARK DESCRIPTION DATE
1 CONCEPT DESIGN 06/11/20
2 FINAL CONCEPT DESIGN 07/10/20
59309.8 SF
Group B
Area
Load Factor:150
Calc Occ: 395
Business
650.53 SF
Group B
Area
Load Factor:15
Calc Occ: 43
Business
267.41 SF
Group B
Area
Load Factor:30
Calc Occ: 9
Business
267.91 SF
Group B
Area
Load Factor:30
Calc Occ: 9
Business
1157.67 SF
Group B
Area
Load Factor:500
Calc Occ: 2
Storage
1672.43 SF
Group A-3
Area
Load Factor:15
Calc Occ: 112
Assembly
2017.25 SF
Group A-3
Area
Load Factor:15
Calc Occ: 135
Assembly
COMMON PATH
66'-8"66'-8"
TRAVEL DISTANCE
278'-3"
BUSINESS
OCC. LOAD FACTOR: 15
ASSEMBLY
STORAGE
OCCUPANCY LEGEND
BUSINESS
OCC. LOAD FACTOR: 30
BUSINESS
OCC. LOAD FACTOR: 150
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:5
2:
P M
CODE PLAN - OPTION 2
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
G-02
06/11/20
1/32" = 1'-0"1
FIRST FLOOR CODE PLAN - OPT 2
Group S-2 Storage 500 2
Group A-3 Assembly 15 247
Group B Business 150 395
Group B Business 30 18
Group B Business 15 43
FIRST FLOOR PLAN
Use Designation Occupancy Classification Occupancy Load Factor Occupant Load
MARK DESCRIPTION DATE
61010.13 SF
Area
Load Factor:150
Calc Occ: 407
Business
1231.48 SF
Group A-3
Area
Load Factor:15
Calc Occ: 82
Assembly
850.73 SF
Group A-3
Area
Load Factor:15
Calc Occ: 57
Assembly
263.36 SF
Group B
Area
Load Factor:30
Calc Occ: 9
Business
263.36 SF
Group B
Area
Load Factor:30 Calc Occ: 9
Business
1174.69 SF
Group B
Area
Load Factor:500
Calc Occ: 2
Storage
654.89 SF
Group B
Area
Load Factor:15 Calc Occ: 44
Business
TRAVEL DISTANCE
267'-4"
COMMON PATH
80'-5"80'-5"
BUSINESS
OCC. LOAD FACTOR: 15
ASSEMBLY
STORAGE
OCCUPANCY LEGEND
BUSINESS
OCC. LOAD FACTOR: 30
BUSINESS
OCC. LOAD FACTOR: 150
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:5
3:
P M
CODE PLAN - OPTION 3
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
G-03
06/11/20
Storage Group S-2 500 2
Assembly Group A-3 15 139
Business Group B 150 407
Business Group B 30 18
Business Group B 15 44
FIRST FLOOR PLAN
Use Designation Occupancy Classification Occupancy Load Factor Occupant Load
MARK DESCRIPTION DATE
59205.7 SF
Load Factor:150 Calc Occ: 395
Area
Business
806.49 SF
Group A-3
Load Factor:15 Calc Occ: 54
Area
Assembly
564.46 SF
Group B
Load Factor:15 Calc Occ: 38
Area
Business
276.15 SF
Group B
Area
Load Factor:30 Calc Occ: 10
Business
1436.36 SF
Group A-3
Load Factor:15
Calc Occ: 96
Area Assembly
272.95 SF
Group B
Load Factor:500
Calc Occ: 1
Area
Storage
1150 SF
Group B
Load Factor:500
Calc Occ: 3
Area
Storage
1738.39 SF
Group A-3
Load Factor:15
Calc Occ: 116
Area
Assembly
COMMON PATH
67'-4"67'-4"
TRAVEL DISTANCE
273'-4"
COMMON PATH
86'-11"86'-11"
TRAVEL DISTANCE
78'-2"
BUSINESS
OCC. LOAD FACTOR: 15
ASSEMBLY
STORAGE
OCCUPANCY LEGEND
BUSINESS
OCC. LOAD FACTOR: 30
BUSINESS
OCC. LOAD FACTOR: 150
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:4
8:
P M
CODE PLAN - SELECTED OPTION
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
G-04
07/09/20
MARK DESCRIPTION DATE
1 FINAL CONCEPT DESIGN 07/10/20
Group S-2 Storage MEP 500 3
Group S-2 Storage MEP 500 1
Group A-3 Assembly Lounge/Break Area 15 116
Group A-3 Assembly Training Room 15 96
Group A-3 Assembly Conference 15 54
Group B Business Office Lab 150 395
Group B Business Collaboration 15 38
Group B Business Collaboration 30 10
FIRST FLOOR PLAN
Use Designation Occupancy Classification Occupancy Load Factor Occupant Load
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
III
DATA
ROOM
DATA
ROOM
MASS
SPECTROMETRY
DATA
ROOM
DATA
ROOM
ICP AES
ATOMIC
ABSORPTION
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
I
SEPARATION
II
FCC
CONFERENCE
RM
FCC
DIRECTOR'S
OFFICE
LAB
DIRECTOR
III
TEAM
LEADER
III
TEAM
LEADER II
LAB
DIRECTOR
II
TEAM
LEADER I
INORGANIC
SAMPLE
PREP.
ICP MASS
SPECTROMETRY
DATA
ROOM
STANDARDS
PREPARATION
ANALYTICAL
SAMPLE
PREP.
ELEC.
TELE.
FTIR
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
R&E
OFFICE
OFFICE
OFFICE
HEARING
RM
JAN.
WOMENS
MENS
161B 159B
GENERAL
LAB
STORAGE
010A
MENS
010B
ELECT.
REPAIR
ELECTRIC
JANITOR
C O
R R
ID
O
R
A
TELEPHONE
C O
R R
ID
O
R
A
011A
WOMENS
LOCKERS
TOILETS
011B
INSPECTION
STOREROOM
COMPLIANCE
STOREROOM
OFFICE
CSO
OFFICE
CSO
BRANCH
DIRECTOR
INVESTIGATION
DEPTY.
DIRECTOR
OFFICE
COMPLIANCE
OFFICE
COMPLIANCE
OFFICE
COMPLIANCE
OFFICE
COMPLIANCE
IMPORT
MGR.
SCO
BRANCH
DIRECTOR
COMPLIANCE
OFFICE
ACCTG.
SECTY.
D.D.
D.P.U.
EQUIPMENT
SECTY.
COMPUTER
CENTER
OPEN
OFFICES
FILE
ROOM
021A
MAIL/FILE/COPY
ROOM
CORRIDOR
OFFICE
ACCTG.
CORRIDOR
LIBRARY
MEDIA
CENTER
OFFICE
PAS
D.D.
CONFR.
RM.
OPEN
OFFICES
AREA
038A
OPEN
OFFICES
AREA
DATA RM.
DATA
ROOM
GENERAL
CHEMISTRY
LAB
GAS
CYLINDER
STORAGE
054A
SUPPLY
CLERK
FREEZER
REFRIGERATOR
SECURED
CORRIDOR
OFFICE
STORAGE
ANALYZED
AND
UN-ANALYZED
SAMPLE
ENVIR.
CHAM.
ENVIR.
CHAM.
ELECTRICAL
COMPUTER/
EVIDENCE
DESTRUCTION
C O
R R
ID
O
R
161C 159C
ADMIN
OFFICER
TOXICOL.
STATIST.
FOOD
TECHNIC.
MAIL/FILE/COPY
FCC
OPEN
OFFICE
AREA
WOMEN
MEN
CORRIDOR
DATA
ROOM
COMPRESSOR
095C
GAS
CYLINDER
STOR.
095A
GAS
CYCLINDER
STOR.
095B
DATA
ROOM
MICROSCOPY/
PHOTOGRAPHY
INVEST.
SAMPLE
PREP
OFFICE
CSO
EVIDENCE
ROOM
DRUG
STOR.
VAULT
CLOSET
003A
OFFICE
STORAGE
AIRLOCK
C O
R R
ID
O
R
DARK
ROOM
FINGERPRINT
LAB
ELECTRON
MICROSCOPY
POISON
APPLICATION
EFFECTS
075LAUNDRY/
GLASSWARE
WASHING
DRY
CHEMICAL
STORAGE
GAS
CYLINDER
STORAGE
VOLATILE
SOLVENTS
LAB
EQUIPMENT
STORAGE
CORRIDOR
SHIPPING
CLERK
C O
R R
ID
O
R
C O
R R
ID
O
R
SHIPPING/
RECEIVING
HAZARD.
WASTE
FOOD
SERVICE
AREA
VENDING
CONFERENCE
CENTER
LOBBY
CORRIDOR
CIRCULATION/UTILITY
SPINE
C O
R R
ID
O
R
C O
R R
ID
O
R
PHOTOGRAPH
DOCUMENT
DATA RM
ION
CHROMOTOGRAPHY
CYLINDER
STOR
116B
COMPRESSOR
116D
GAS
CYLINDER
STOR.
116CGAS
CYLINDER
STOR.
116A
C O
R R
ID
O
R
GAS
CYLINDER
STOR.
130B
GAS
CYLINDER
STOR.
130A
CORRIDOR
UPS
ROOM
FCC
LIBRARY
CIRCULATION/UTILITY
SPINE
LAB
DIRECTOR
I
ELEVATOR
AIRLOCK
053A
M/L OPEN
OFFICE
AREA
MECHANICAL
VESTIBULE
DISTRICT
DIRECTOR
ADMIN.
OFFICER
STAIR #1
CLEAN
RM
CLEAN
RM
CLEAN
RM
CHANG.
RM
RECEPTION
PROCEDURE
RM 2
SAMPLE
CUSTODY
PROCEDURE
RM 1
ANTE
ROOM
SAMPLE
TRIAGE
LAB
ANTEROOM/
STORAGE/
JANITOR
ELECTRICAL
CORRIDOR
RENOVATION VARIES BASED ON
OPTION. REFER TO PLAN OPTION
SHEETS.
ALL EXISTING LABS TO REMAIN REQUIRE
UPDATED MECHANICAL AND ELECTRICAL
SYSTEMS, INCLUDING NEW CEILINGS, TYP.
DISTRIBUTION OF
ADMINISTRATIVE SPACE
AND LABORATORY SPACE
VARIES BETWEEN
OPTION. REFER TO PLAN
OPTION SHEETS.
GUT RENOVATION
ALL NEW MEP
ADMIN.SPACE RENOVATIONS
GUT RENOVATION
ALL NEW MEP
GUT RENOVATION
MOVE WALL, DOORS,
CASEWORK, FUME HOODS,
AND/OR PATCH FINISHES
GSA RENOVATIONS
CARD READERS ON ALL
LABORATORY DOORS
MECHANICAL -
ELECTRICAL - NEW LIGHTING
PLUMBING -
LABORATORY RENOVATIONS
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:5
4:
P M
DEMOLITION/RENOVATION PLAN - FIRST FLOOR
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
AD-01
06/11/20
1/32" = 1'-0"1
FIRST FLOOR PLAN - EXISTING
MARK DESCRIPTION DATE
MECH.
B002
ELEV
VEST
B003
OFFICE/SHOP
B005
ELEV
MACH
ROOM
B004
CORRIDOR
B006
ELEVATOR
GARAGE
DEPARTMENT LEGEND
BUILDING SUPPORT
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:4
3:
P M
GARAGE FLR PLAN - EXIST SPACE USE DIAGRAM
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-01
06/11/20
1/32" = 1'-0"1
GARAGE FLOOR PLAN - EXISTING
OUTLINE OF FIRST FLOOR ABOVE
MARK DESCRIPTION DATE
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
III
DATA
ROOM
DATA
ROOM
MASS
SPECTROMETRY
DATA
ROOM
DATA
ROOM
ICP AES
ATOMIC
ABSORPTION
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
I
SEPARATION
II
FCC
CONFERENCE
RM
FCC
DIRECTOR'S
OFFICE
LAB
DIRECTOR
III
TEAM
LEADER
III
TEAM
LEADER II
LAB
DIRECTOR
II
TEAM
LEADER I
INORGANIC
SAMPLE
PREP.
ICP MASS
SPECTROMETRY
DATA
ROOM
STANDARDS
PREPARATION
ANALYTICAL
SAMPLE
PREP.
ELEC.
TELE.
FTIR
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
R&E
OFFICE
OFFICE
OFFICE
HEARING
RM
JAN.
WOMENS
MENS
161B 159B
GENERAL
LAB
STORAGE
010A
MENS
010B
ELECT.
REPAIR
ELECTRIC
JANITOR
C O
R R
ID
O
R
A
TELEPHONE
C O
R R
ID
O
R
A
011A
WOMENS
LOCKERS
TOILETS
011B
INSPECTION
STOREROOM
COMPLIANCE
STOREROOM
OFFICE
CSO
OFFICE
CSO
BRANCH
DIRECTOR
INVESTIGATION
DEPTY.
DIRECTOR
OFFICE
COMPLIANCE
OFFICE
COMPLIANCE
OFFICE
COMPLIANCE
OFFICE
COMPLIANCE
IMPORT
MGR.
SCO
BRANCH
DIRECTOR
COMPLIANCE
OFFICE
ACCTG.
SECTY.
D.D.
D.P.U.
EQUIPMENT
SECTY.
COMPUTER
CENTER
OPEN
OFFICES
FILE
ROOM
021A
MAIL/FILE/COPY
ROOM
CORRIDOR
OFFICE
ACCTG.
CORRIDOR
LIBRARY
MEDIA
CENTER
OFFICE
PAS
D.D.
CONFR.
RM.
OPEN
OFFICES
AREA
038A
OPEN
OFFICES
AREA
DATA RM.
DATA
ROOM
GENERAL
CHEMISTRY
LAB
GAS
CYLINDER
STORAGE
054A
SUPPLY
CLERK
FREEZER
REFRIGERATOR
SECURED
CORRIDOR
OFFICE
STORAGE
ANALYZED
AND
UN-ANALYZED
SAMPLE
ENVIR.
CHAM.
ENVIR.
CHAM.
ELECTRICAL
COMPUTER/
EVIDENCE
DESTRUCTION
C O
R R
ID
O
R
161C 159C
ADMIN
OFFICER
TOXICOL.
STATIST.
FOOD
TECHNIC.
MAIL/FILE/COPY
FCC
OPEN
OFFICE
AREA
WOMEN
MEN
CORRIDOR
DATA
ROOM
COMPRESSOR
095C
GAS
CYLINDER
STOR.
095A
GAS
CYCLINDER
STOR.
095B
DATA
ROOM
MICROSCOPY/
PHOTOGRAPHY
INVEST.
SAMPLE
PREP
OFFICE
CSO
EVIDENCE
ROOM
DRUG
STOR.
VAULT
CLOSET
003A
OFFICE
STORAGE
AIRLOCK
C O
R R
ID
O
R
DARK
ROOM
FINGERPRINT
LAB
ELECTRON
MICROSCOPY
POISON
APPLICATION
EFFECTS
075LAUNDRY/
GLASSWARE
WASHING
DRY
CHEMICAL
STORAGE
GAS
CYLINDER
STORAGE
VOLATILE
SOLVENTS
LAB
EQUIPMENT
STORAGE
CORRIDOR
SHIPPING
CLERK
CORRIDOR
C O
R R
ID
O
R
SHIPPING/
RECEIVING
HAZARD.
WASTE
FOOD
SERVICE
AREA
VENDING
CONFERENCE
CENTER
LOBBY
CORRIDOR
CIRCULATION/UTILITY
SPINE
C O
R R
ID
O
R
C O
R R
ID
O
R
PHOTOGRAPH
DOCUMENT
DATA RM
ION
CHROMOTOGRAPHY
CYLINDER
STOR
116B
COMPRESSOR
116D
GAS
CYLINDER
STOR.
116CGAS
CYLINDER
STOR.
116A
C O
R R
ID
O
R
GAS
CYLINDER
STOR.
130B
GAS
CYLINDER
STOR.
130A
CORRIDOR
UPS
ROOM
FCC
LIBRARY
CIRCULATION/UTILITY
SPINE
LAB
DIRECTOR
I
ELEVATOR
AIRLOCK
053A
M/L OPEN
OFFICE
AREA
MECHANICAL
VESTIBULE
DISTRICT
DIRECTOR
ADMIN.
OFFICER
STAIR #1
CLEAN
RM
CLEAN
RM
CLEAN
RM
CHANG.
RM
RECEPTION
PROCEDURE
RM 2
SAMPLE
CUSTODY
PROCEDURE
RM 1
ANTE
ROOM
SAMPLE
TRIAGE
LAB
ANTEROOM/
STORAGE/
JANITOR
ELECTRICAL
CORRIDOR
DEPARTMENT LEGEND
ADMINISTRATIVE SPACE
BUILDING SUPPORT
CIRCULATION
COMMON SPACE
LABORATORY (CLOSED)
LABORATORY (OPEN)
LABORATORY SUPPORT
OFFICE
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:4
6:
P M
1ST FLOOR PLAN - EXIST SPACE USE DIAGRAM
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-02
06/11/20
MARK DESCRIPTION DATE
MECHANICAL
HIGH ROOF
MAIN ROOF
MAIN ROOF
DEPARTMENT LEGEND
BUILDING SUPPORT
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:4
7:
P M
ROOF PLAN - EXISTING
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-03
06/11/20
1/32" = 1'-0"1
ROOF PLAN - EXISTING
MARK DESCRIPTION DATE
OFFICE OFFICE OFFICE OFFICE
FLEXOFFICE OFFICEOFFICE
PRINT/
COFFEE
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
MASS
SPECTROMETRY
DATA
ROOM
DATA
ROOM
ICP
AES
ATOMIC
ABSORPTION
INORGANIC
SAMPLE
PREP.
ICP
MASS
SPECTROMETRY
DATA
ROOM
STANDARDS
PREPARATION
ANALYTICAL
SAMPLE
PREP.
ELEC.TELE.
FTIR
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
COMPRESSOR
GAS
CYLINDER
STOR.
DATA
ROOM
MICROSCOPY/
PHOTOGRAPHY
DARK
ROOM
FINGERPRINT
LAB
ELECTRON
MICROSCOPY
C O
R R
ID
O
R
C O
R R
ID
O
R
PHOTOGRAPH
DOCUMENT
DATA
RM
ION
CHROMOTOGRAPHY
COMPRESSOR
C O
R R
ID
O
R
CLEAN
RM
CLEAN
RM
CLEAN
RM
CHANG.
RM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
I
SEPARATION
II CORRIDOR
UPS
ROOM
PROCEDURE
RM 2
SAMPLE
CUSTODY
PROCEDURE
RM 1
LAB
ANTE
ROOM
SAMPLE
TRIAGE
ELECTRICAL
ANTEROOM/
STORAGE/
JANITOR
MOTHERS'
RM
MEDIUM
CONF.
MEDIUM
CONF.
FCC
CONFERENCE
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
OFFICE
FCC
OPEN
WORK
AREA
MEETING
ROOM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
LAB
EQ
STOR
EVID
DEST
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
PHOTO
DOC
ANALY
PREP
GLASSWASH
MEETING
ROOM
KITCHENETTE
CORRIDOR
MOLEC
BIO
MICROBIO
ANALYZED
AND
UN-ANALYZED
SAMPLE
EVIDENCE
ROOM
DRUG
STOR.
FREEZER
SECURED
CORRIDOR
REFRIGERATOR
SUPPLY
CLERK
VAULT
EXISTING
IT RM
NEW
CHEM
LAB &
SEP 3
LAB
POISON
APPLICATION
EFFECTS
DRY
CHEMICAL
STORAGE
GAS
CYLINDER
STORAGE
VOLATILE
SOLVENTS
SHIPPING
CLERK
SHIPPING/
RECEIVING
ELEVATOR
LAB
EQUIPMENT
STORAGE
C O
R R
ID
O
R
JAN.
WOMENS
MENS
GENERAL
LAB
STORAGE
ELECTRICAL
C O
R R
ID
O
R
C O
R R
ID
O
R
MECHANICAL
MASS
SPEC
TRACE
EVID
WOMEN
MEN
DEPARTMENT LEGEND
ADMINISTRATIVE
SPACE
BUILDING SUPPORT
CIRCULATION
COMMON SPACE
LABORATORY (CLOSED)
LABORATORY (OPEN)
LABORATORY SUPPORT
OFFICE
TRAINING/DINING
LOUNGE
CAFE
ELECTRIC
JANITOR
MENS
OFFICE
STORAGE
RECEPTION
TELEPHONE
WOMENS
LOCKERS
TOILETS
LOBBY
CLOSET
C O
R R
ID
O
R
C O
R R
ID
O
R
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
CYLINDER
STOR
GAS
CYLINDER
STOR.
GAS
CYCLINDER
STOR.
C O
R R
ID
O
R
HAZARD.
WASTE
STAIR
#1
BADGING
IH/SAFETY
STOR
CIRCULATION/UTILITY
SPINE
GOWNING/
TOILET
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:3
0:
P M
CONCEPT PLAN - FIRST FLOOR - OPTION 1
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-10
06/11/20
1/32" = 1'-0"1
FIRST FLOOR PLAN - OPTION 1
MARK DESCRIPTION DATE
1 CONCEPT DESIGN 06/11/20
2 FINAL CONCEPT DESIGN 07/10/20
IT
OFFICE
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
MASS
SPECTROMETRY
DATA
ROOM
DATA
ROOM
ICP
AES
ATOMIC
ABSORPTION
INORGANIC
SAMPLE
PREP.
ICP
MASS
SPECTROMETRY
DATA
ROOM
STANDARDS
PREPARATION
ANALYTICAL
SAMPLE
PREP.
ELEC.
TELE.
FTIR
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
COMPRESSOR
GAS
CYLINDER
STOR.
DATA
ROOM
MICROSCOPY/
PHOTOGRAPHY
DARK
ROOM
FINGERPRINT
LAB
ELECTRON
MICROSCOPY
C O
R R
ID
O
R
PHOTOGRAPH
DOCUMENT
DATA
RM
ION
CHROMOTOGRAPHY
C O
R R
ID
O
R
CLEAN
RM
CLEAN
RM
CLEAN
RM
CHANG.
RM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
I
SEPARATION
II
CORRIDOR
UPS
ROOM
PROCEDURE
RM 2
SAMPLE
CUSTODY
PROCEDURE
RM 1
LAB
ANTE
ROOM
SAMPLE
TRIAGE
ELECTRICAL
ANTEROOM/
STORAGE/
JANITOR
ANALYZED
AND
UN-ANALYZED
SAMPLE
EVIDENCE
ROOM
FREEZER
REFRIGERATOR
SECURED
CORRIDOR
SUPPLY
CLERK
VAULT
DRUG
STOR.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE OFFICE OFFICE
MEDIUM
CONF.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MEDIUM
CONF.
FLEX
PRINT/COFFEE
FCC
CONFERENCE
CORRIDOR
POISON
APPLICATION
EFFECTS
DRY
CHEMICAL
STORAGE
GAS
CYLINDER
STORAGE
VOLATILE
SOLVENTS
SHIPPING
CLERK
SHIPPING/
RECEIVING
ELEVATOR
LAB
EQUIPMENT
STORAGE
JAN.
GENERAL
LAB
STORAGE
ELECTRICAL
C O
R R
ID
O
R
MECHANICAL
NEW
CHEM
LAB
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
CONF
RM
CONF
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
EXIST
IT RM
DATA
RM
NEW
SEP III
LAB
DEPARTMENT LEGEND
ADMINISTRATIVE
SPACE
BUILDING SUPPORT
CIRCULATION
COMMON SPACE
LABORATORY (CLOSED)
LABORATORY (OPEN)
LABORATORY SUPPORT
WOMEN
MEN
MASS
SPEC
TRACE
EVID
TRAINING/DININGLOUNGE
CAFE
OPEN
WORK
AREA
PATIO
RECEPTION/
BADGING
TELEPHONE
ELECTRIC
JANITOR
C O
R R
ID
O
R
C O
R R
ID
O
R
C O
R R
ID
O
R
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
COMPRESSOR
GAS
CYLINDER
STOR.
CYLINDER
STOR
GAS
CYLINDER
STOR.
C O
R R
ID
O
R
GAS
CYCLINDER
STOR.
MOLEC
BIO
MICROBIO
HAZARD.
WASTE
STAIR
#1
LAB
EQ
STOR
EVID
DEST
MOTHERS'
RM
LOBBY
SHOWERLOCKERS/
VENDING
OFFICE
STORAGE
IH/SAFETY
STOR
C O
R R
ID
O
R
DATA
RM
DATA
RM
DATA
RM
DATA
RM
WOMENS
MENS
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:3
3:
P M
CONCEPT PLAN - FIRST FLOOR - OPTION 2
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-11
06/11/20
1/32" = 1'-0"1
FIRST FLOOR PLAN - OPTION 2
MARK DESCRIPTION DATE
LOCKERS
OFFICE OFFICE OFFICE
OFFICE
PRINT OFFICEOFFICE
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
MASS
SPECTROMETRY
DATA
ROOM
DATA
ROOM
ICP
AES
ATOMIC
ABSORPTION
INORGANIC
SAMPLE
PREP.
ICP
MASS
SPECTROMETRY
DATA
ROOM
STANDARDS
PREPARATION
ANALYTICAL
SAMPLE
PREP.
ELEC.
TELE.
FTIR
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
COMPRESSOR
GAS
CYLINDER
STOR.
DATA
ROOM
MICROSCOPY/
PHOTOGRAPHY
DARK
ROOM
FINGERPRINT
LAB
ELECTRON
MICROSCOPY
C O
R R
ID
O
R
C O
R R
ID
O
R
PHOTOGRAPH
DOCUMENT
DATA
RM
ION
CHROMOTOGRAPHY
GAS
CYLINDER
STOR.
C O
R R
ID
O
R
CLEAN
RM
CLEAN
RM
CLEAN
RM
CHANG.
RM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
I
SEPARATION
II
CORRIDOR
UPS
ROOM
OFFICE
OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE
PROCEDURE
RM 2
SAMPLE
CUSTODY
PROCEDURE
RM 1
ANTE
ROOM
SAMPLE
TRIAGE
LAB
ANTEROOM/
STORAGE/
JANITOR
ELECTRICAL
CORRIDOR
MEDIUM
CONF.
MEDIUM
CONF.
OFFICE
CONFERENCE/TRAINING
OFFICE
MOTHERS'
RM
WOMEN
MEN
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
ANALYZED
AND
UN-ANALYZED
SAMPLE
EVIDENCE
ROOM
FREEZER
REFRIGERATOR
SECURED
CORRIDOR
MASS
SPEC
DEPARTMENT LEGEND
ADMINISTRATIVE
SPACE
BUILDING SUPPORT
CIRCULATION
COMMON SPACE
LABORATORY (CLOSED)
LABORATORY (OPEN)
LABORATORY SUPPORT
OFFICE
SUPPLY
CLERK
DRUG
STOR.
VAULT
POISON
APPLICATION
EFFECTS
DRY
CHEMICAL
STORAGE
GAS
CYLINDER
STORAGE
VOLATILE
SOLVENTS
SHIPPING
CLERK
SHIPPING/
RECEIVING
ELEVATOR
LAB
EQUIPMENT
STORAGE
JAN.
GENERAL
LAB
STORAGE
ELECTRICAL
C O
R R
ID
O
R
MECHANICAL
ELECTRIC
JANITOR
CIRCULATION/UTILITY
SPINE
LOUNGE
CAFE
FUTURE
LAB
SPACE
WOMENS
TOILET
MENS
TOILET
MOLEC
BIO
MICROBIO
RECEPTION/
BADGING
TELEPHONE
CYLINDER
STOR
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
C O
R R
ID
O
R
C O
R R
ID
O
R
C O
R R
ID
O
R
COMPRESSOR
GAS
CYCLINDER
STOR.
TRACE
EVID
HAZARD.
WASTE
STAIR
#1
LAB
EQ
STOR
EVID
DEST
CHEM
LAB &
SEP III
LAB
EXISTING
IT RM
LOBBY
OFFICE
STORAGE
FCC
CONFERENCE
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:3
4:
P M
CONCEPT PLAN - FIRST FLOOR - OPTION 3
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-12
06/11/20
1/32" = 1'-0"1
01-A-FLOOR PLAN_ADMIN - OPTION 3
MARK DESCRIPTION DATE
1 CONCEPT DESIGN 06/11/20
2 FINAL CONCEPT DESIGN 07/10/20
IT
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
MASS
SPECTROMETRY
DATA
ROOM
DATA
ROOM
ICP
AES
ATOMIC
ABSORPTION
INORGANIC
SAMPLE
PREP.
ICP
MASS
SPECTROMETRY
DATA
ROOM
STANDARDS
PREPARATION
ANALYTICAL
SAMPLE
PREP.
ELEC.TELE.
FTIR
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
COMPRESSOR
GAS
CYLINDER
STOR.
DATA
ROOM
MICROSCOPY/
PHOTOGRAPHY
DARK
ROOM
FINGERPRINT
LAB
ELECTRON
MICROSCOPY
C O
R R
ID
O
R
C O
R R
ID
O
R
PHOTOGRAPH
DOCUMENT
DATA
RM
ION
CHROMOTOGRAPHY
COMPRESSOR
C O
R R
ID
O
R
CLEAN
RM
CLEAN
RM
CLEAN
RM
CHANG.
RM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
I
SEPARATION
II CORRIDOR
UPS
ROOM
PROCEDURE
RM 2
SAMPLE
CUSTODY
PROCEDURE
RM 1
LAB
ANTE
ROOM
SAMPLE
TRIAGE
ELECTRICAL
ANTEROOM/
STORAGE/
JANITOR
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
LAB
EQ
STOR
EVID
DEST
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
PHOTO
DOC
ANALY
PREP
GLASSWASH
CORRIDOR
MOLEC
BIO
MICROBIO
ANALYZED
AND
UN-ANALYZED
SAMPLE
EVIDENCE
ROOM
DRUG
STOR.
FREEZER
SECURED
CORRIDOR
REFRIGERATOR
SUPPLY
CLERK
VAULT
EXISTING
IT RM
NEW
CHEM
LAB &
SEP 3
LAB
POISON
APPLICATION
EFFECTS
DRY
CHEMICAL
STORAGE
GAS
CYLINDER
STORAGE
VOLATILE
SOLVENTS
SHIPPING
CLERK
SHIPPING/
RECEIVING
ELEVATOR
LAB
EQUIPMENT
STORAGE
C O
R R
ID
O
R
JAN.
GENERAL
LAB
STORAGE
ELECTRICAL
C O
R R
ID
O
R
MECHANICAL
MASS
SPEC
TRACE
EVID
WOMEN
MEN
DEPARTMENT LEGEND
ADMINISTRATIVE
SPACE
BUILDING SUPPORT
CIRCULATION
COMMON SPACE
LABORATORY (CLOSED)
LABORATORY (OPEN)
LABORATORY SUPPORT
OFFICE
ELECTRIC
JANITOR
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
CYLINDER
STOR
GAS
CYLINDER
STOR.
GAS
CYCLINDER
STOR.
HAZARD.
WASTE
STAIR
#1
IH/SAFETY
STOR
CIRCULATION/UTILITY
SPINE
GOWNING/
TOILET
OFFICE OFFICE OFFICE OFFICE
FLEXOFFICE OFFICEOFFICE
PRINT/
COFFEE
MOTHERS'
RM
FLEX MEDIUM
CONF.
FCC
CONFERENCE
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
OFFICE
FCC
OPEN
WORK
AREA
OFFICE
CONFERENCE
C O
R R
ID
O
R
WOMENS
MENSC
O
R R
ID
O
R
LOBBY
OFFICE
STORAGE
RECEPTION/BADGING
TRAINING/DININGLOUNGE
CAFE
C O
R R
ID
O
R
PATIO
MENSWOMENS
TELEPHONE
KITCHENETTE
ELECT
REPAIR
IT
OFFICE
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 8/
:3
9:
P M
SELECTED CONCEPTUAL DESIGN OPTION
F
O R
E N
S
IC
C H
E M
IS
T
R Y
C E
N T
E R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-13
07/08/20
1/32" = 1'-0"1
FIRST FLOOR PLAN - SELECTED CONCEPTUAL DESIGN OPTION
MARK DESCRIPTION DATE
1 FINAL CONCEPT DESIGN 07/10/20
NathanLIngersoll Rectangle
NathanLIngersoll Rectangle
NathanLIngersoll Rectangle
NathanLIngersoll Arrow
NathanLIngersoll Arrow
NathanLIngersoll Callout Replacement of Fire Alarm, Sprinker system, and lighting infrastructure within these spaces shall be priced as part of the "FCC Building Enhancements Option."
NathanLIngersoll Rectangle
NathanLIngersoll Arrow
OFFICE OFFICE OFFICE OFFICE
FLEXOFFICE OFFICEOFFICEPRINT/
COFFEE
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
MASS
SPECTROMETRY
DATA
ROOM
DATA
ROOM
ICP
AES
ATOMIC
ABSORPTION
INORGANIC
SAMPLE
PREP.
ICP
MASS
SPECTROMETRY
DATA
ROOM
STANDARDS
PREPARATION
ANALYTICAL
SAMPLE
PREP.
ELEC.
TELE.
FTIR
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
COMPRESSOR
GAS
CYLINDER
STOR.
DATA
ROOM
MICROSCOPY/
PHOTOGRAPHY
DARK
ROOM
FINGERPRINT
LAB
ELECTRON
MICROSCOPY
C O
R R
ID
O
R
C O
R R
ID
O
R
PHOTOGRAPH
DOCUMENT
DATA
RM
ION
CHROMOTOGRAPHY
C O
R R
ID
O
R
CLEAN
RM
CLEAN
RM
CLEAN
RM
CHANG.
RM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
I
SEPARATION
II
CORRIDOR
UPS
ROOM
PROCEDURE
RM 2
SAMPLE
CUSTODY
PROCEDURE
RM 1
ANTE
ROOM
SAMPLE
TRIAGE
LAB
ANTEROOM/
STORAGE/
JANITOR
ELECTRICAL
C O
R R
ID
O
R
MOTHERS'
RM MEDIUM
CONF.
MEDIUM
CONF.
FCC
CONFERENCE
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
OFFICE
FCC
OPEN
WORK
AREA
MEETING
ROOM
MEETING
ROOM
KITCHENETTE
SUPPLY
CLERK
FREEZER
REFRIGERATOR
SECURED
CORRIDOR
ANALYZED
AND
UN-ANALYZED
SAMPLE
EVIDENCE
ROOM
DRUG
STOR.
VAULT
POISON
APPLICATION
EFFECTS
DRY
CHEMICAL
STORAGE
GAS
CYLINDER
STORAGE
VOLATILE
SOLVENTS
SHIPPING
CLERK
SHIPPING/
RECEIVING
ELEVATOR
LAB
EQUIPMENT
STORAGE
JAN.
WOMENS MENS
GENERAL
LAB
STORAGE
ELECTRICAL
C O
R R
ID
O
R
C O
R R
ID
O
R
MECHANICAL
WOMEN
MEN
MENS
ELECTRIC
JANITOR
OFFICE
STORAGE
CIRCULATION/UTILITY
SPINE
TRAINING/DINING
LOUNGE
CAFE
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
NEW
CHEM
LAB &
SEP 3
LAB
PHOTO
DOC
MOLEC
BIO
ANALY
PREP
MICROBIO
WOMENS
LOCKERS
TOILETS
C O
R R
ID
O
R
TELEPHONE
RECEPTION
LOBBY
BADGING
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
LAB
EQ
STOR
EVID
DEST
HAZARD.
WASTE
TRACE
EVID
MASS
SPEC
EXISTING
IT RM
GAS
CYCLINDER
STOR.
COMPRESSOR
CYLINDER
STOR
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
Phase 1: 1,810 SF Non-FCC Administrative space (major renovation)
Phase 1: 3,153 SF Common Space (selective renovation)
Phase 1: 12,453 SF New lab in former administrative space (major renovation)
Phase 2: 5,254 SF Lab Renovation (selective renovation, re: demo drawing)
Phase 2: 15,880 SF Lab Renovation (selective renovation, re: demo drawing)
Phase 2: 5,406 SF FCC Administrative Space (selective renovation, re:
demo drawing)
PHASE 1
LAB RENOVATION
PHASE 1
ADMIN RENOVATION
PHASE 1
ADMIN/COMMON
SPACES RENOVATION
PHASE 2
LAB RENOVATION
PHASE 2
ADMIN RENOVATION
PHASE 2
ADMIN/COMMON
SPACES RENOVATION
BUILDING SUPPORT RENOVATION - MULTIPLE PHASES
PHASING LEGEND
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:5
6:
P M
PHASING PLAN - FIRST FLOOR - OPTION 1
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-20
06/11/20
1/32" = 1'-0"1
PHASING PLAN - OPTION 1
MARK DESCRIPTION DATE
OFFICE
OFFICE
OFFICE
OFFICE OFFICE OFFICE
MEDIUM
CONF.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MEDIUM
CONF.
FLEX
PRINT/COFFEE
FCC
CONFERENCE
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
MASS
SPECTROMETRY
DATA
ROOM
DATA
ROOM
ICP
AES
ATOMIC
ABSORPTION
INORGANIC
SAMPLE
PREP.
ICP
MASS
SPECTROMETRY
DATA
ROOM
STANDARDS
PREPARATION
ANALYTICAL
SAMPLE
PREP.
ELEC.
TELE.
FTIR
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
COMPRESSOR
GAS
CYLINDER
STOR.
DATA
ROOM
MICROSCOPY/
PHOTOGRAPHY
DARK
ROOM
FINGERPRINT
LAB
ELECTRON
MICROSCOPY
C O
R R
ID
O
R
C O
R R
ID
O
R
PHOTOGRAPH
DOCUMENT
DATA
RM
ION
CHROMOTOGRAPHY
CORRIDOR
CLEAN
RM
CLEAN
RM
CLEAN
RM
CHANG.
RM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
I
SEPARATION
II
CORRIDOR
UPS
ROOM
PROCEDURE
RM 2
SAMPLE
CUSTODY
PROCEDURE
RM 1
ANTE
ROOM
SAMPLE
TRIAGE
LAB
ANTEROOM/
STORAGE/
JANITOR
ELECTRICAL
CORRIDOR
SUPPLY
CLERK
FREEZER
REFRIGERATOR
SECURED
CORRIDOR
ANALYZED
AND
UN-ANALYZED
SAMPLE
EVIDENCE
ROOM
DRUG
STOR.
VAULT
POISON
APPLICATION
EFFECTS
DRY
CHEMICAL
STORAGE
GAS
CYLINDER
STORAGE
VOLATILE
SOLVENTS
SHIPPING
CLERK
SHIPPING/
RECEIVING
ELEVATOR
LAB
EQUIPMENT
STORAGE
JAN.
GENERAL
LAB
STORAGE
ELECTRICAL
C O
R R
ID
O
R
MECHANICAL
WOMEN
MEN
ELECTRIC
JANITOR
CIRCULATION/UTILITY
SPINE
TRAINING/DININGLOUNGE
CAFE
OPEN
WORK
AREA
RECEPTION/
BADGING
TELEPHONE
Phase 1: 14,278 SF New lab in former administrative space (major renovation)
Phase 1: 3,751 SF Common Space (major renovation)
LOBBY
OFFICE
STORAGE
LOCKERS/
VENDING
SHOWER
MOTHERS'
RM
Phase 1: 5,293 SF FCC Administrative Space (major renovation)
Phase 2: 5,254 SF Lab Renovation (selective renovation, re: demo drawing)
Phase 2: 15,880 SF Lab Renovation (selective renovation, re: demo drawing)
Phase 1:
Renovate Restrooms
C O
R R
ID
O
R
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
COMPRESSOR
GAS
CYLINDER
STOR.
CYLINDER
STOR
GAS
CYLINDER
STOR.
MASS
SPEC
GAS
CYCLINDER
STOR.
TRACE
EVID
MOLEC
BIO
MICROBIO
HAZARD.
WASTE
STAIR
#1
EVID
DEST
LAB
EQ
STOR
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
EXIST
IT RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
CONF
RM
CONF
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
C O
R R
ID
O
R
PHASE 1
LAB RENOVATION
PHASE 1
ADMIN RENOVATION
PHASE 1
ADMIN/COMMON
SPACES RENOVATION
PHASE 2
LAB RENOVATION
PHASE 2
ADMIN RENOVATION
PHASE 2
ADMIN/COMMON
SPACES RENOVATION
BUILDING SUPPORT RENOVATION - MULTIPLE PHASES
PHASING LEGEND
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:5
7:
P M
PHASING PLAN - FIRST FLOOR -OPTION 2
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-21
06/11/20
1/32" = 1'-0"1
PHASING PLAN - OPTION 2
MARK DESCRIPTION DATE
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
MASS
SPECTROMETRY
DATA
ROOM
DATA
ROOM
ICP
AES
ATOMIC
ABSORPTION
INORGANIC
SAMPLE
PREP.
ICP
MASS
SPECTROMETRY
DATA
ROOM
STANDARDS
PREPARATION
ANALYTICAL
SAMPLE
PREP.
ELEC.
TELE.
FTIR
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
COMPRESSOR
GAS
CYLINDER
STOR.
DATA
ROOM
MICROSCOPY/
PHOTOGRAPHY
DARK
ROOM
FINGERPRINT
LAB
ELECTRON
MICROSCOPY
C O
R R
ID
O
R
PHOTOGRAPH
DOCUMENT
DATA
RM
ION
CHROMOTOGRAPHY
C O
R R
ID
O
R
CLEAN
RM
CLEAN
RM
CLEAN
RM
CHANG.
RM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
DATA
ROOM
SEPARATION
I
SEPARATION
II
CORRIDOR
UPS
ROOM
PROCEDURE
RM 2
SAMPLE
CUSTODY
PROCEDURE
RM 1
ANTE
ROOM
SAMPLE
TRIAGE
LAB
ANTEROOM/
STORAGE/
JANITOR
ELECTRICAL
CORRIDOR
SUPPLY
CLERK
FREEZER
REFRIGERATOR
SECURED
CORRIDOR
ANALYZED
AND
UN-ANALYZED
SAMPLE
EVIDENCE
ROOM
DRUG
STOR.
VAULT
POISON
APPLICATION
EFFECTS
DRY
CHEMICAL
STORAGE
GAS
CYLINDER
STORAGE
VOLATILE
SOLVENTS
SHIPPING
CLERK
SHIPPING/
RECEIVING
ELEVATOR
LAB
EQUIPMENT
STORAGE
JAN.
GENERAL
LAB
STORAGE
ELECTRICAL
C O
R R
ID
O
R
MECHANICAL
WOMEN
MEN
ELECTRIC
JANITOR
CIRCULATION/UTILITY
SPINE
OFFICE
OFFICE OFFICE OFFICE
OFFICE
PRINT OFFICEOFFICE
OFFICE
OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE
MEDIUM
CONF.
MEDIUM
CONF.
OFFICE
CONFERENCE/TRAINING
OFFICE
MOTHERS'
RM
LOUNGE
CAFE
Phase 1: 10,126 SF New lab in former administrative space (major renovation)
Phase 1: 1,468 SF Non-FCC Administrative space (major renovation)
Phase 1: 3,307 SF Common Space (major renovation)
Phase 2: 15,880 SF Lab Renovation (selective renovation, re: demo drawing)
Phase 2: 5,254 SF Lab Renovation (selective renovation, re: demo drawing)
Phase 2: 5,406 SF Future Lab Swing Space (major renovation, re:
demo drawing)
Phase 1: 1,888 SF FCC Administrative Space (major renovation)
Phase 1: 491 SF Building Support (major renovation)
WOMENS
TOILET
MENS
TOILET
RECEPTION/
BADGING
LOBBY
OFFICE
STORAGE
TELEPHONE
C O
R R
ID
O
R
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
DATA
RM
CHEM
LAB &
SEP III
LAB
DATA
RM
HAZARD.
WASTE
STAIR
#1
LAB
EQ
STOR
EVID
DEST
C O
R R
ID
O
R
C O
R R
ID
O
R
FUTURE
LAB
SPACE
GAS
CYCLINDER
STOR.
MASS
SPEC
TRACE
EVID
C O
R R
ID
O
R
GAS
CYLINDER
STOR.
CYLINDER
STOR
GAS
CYLINDER
STOR.
COMPRESSOR
GAS
CYLINDER
STOR.
GAS
CYLINDER
STOR.
FCC
CONFERENCE
EXISTING
IT RM
GLASSWASH
ANALY
PREP
PHOTO
DOC
POISON
APPLICATION
EFFECTS
POISON
APPLICATION
EFFECTS
MENS
WOMENS MENS
PHASE 1
LAB RENOVATION
PHASE 1
ADMIN RENOVATION
PHASE 1
ADMIN/COMMON
SPACES RENOVATION
PHASE 2
LAB RENOVATION
PHASE 2
ADMIN RENOVATION
PHASE 2
ADMIN/COMMON
SPACES RENOVATION
BUILDING SUPPORT RENOVATION - MULTIPLE PHASES
PHASING LEGEND
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:5
8:
P M
PHASING PLAN - FIRST FLOOR - OPTION 3
F O
R E
N S
IC
C
H E
M
IS
T R
Y C
E N
T E
R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-22
06/11/20
1/32" = 1'-0"1
PHASING PLAN - OPTION 3
MARK DESCRIPTION DATE
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:0
8:
P M
ROOM STYLE SCHEDULE
F
O R
E N
S
IC
C H
E M
IS
T
R Y
C E
N T
E R
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
A-30
06/11/20
QA Schedule - Room Style Schedule
Key Name Department Wall Finish Floor Finish Base Finish Ceiling Finish Recycling (gal) Comments
OFFICE ADMINISTRATIVE SPACE PT CPT RB ACT 10
OPEN WORK AREA ADMINISTRATIVE SPACE PT CPT/EP RB ACT
PRINT/COPY ADMINISTRATIVE SPACE PT EP RB ACT 30
BUILDING SUPPORT BUILDING SUPPORT PT CFS RB ACT
MOTHERS ROOM BUILDING SUPPORT PT CPT RB ACT
TOILET/LOCKERS BUILDING SUPPORT PT EP CT GYP
CIRCULATION CIRCULATION PT EP RB EXPOSED
CONFERENCE COMMON SPACE PT CPT RB ACT 30
KITCHEN/DINING COMMON SPACE PT CPT/EP RB ACT/EXPOSED
LOBBY COMMON SPACE PT EP RB EXPOSED
LABORATORY (CLOSED) LABORATORY (CLOSED) PT EP RB ACT
LABORATORY (OPEN) LABORATORY (OPEN) PT EP EP ACT
LAB SUPPORT SPACE LABORATORY SUPPORT PT EP RB ACT
MARK DESCRIPTION DATE
LAB EQ STOR
482.99 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
EVID DEST
138.7 SF
PHOTO DOC
463.75 SF
ANALY PREP
463.75 SF GLASSWASH
266.9 SF
NEW CHEM LAB & SEP 3 LAB
6086.62 SF
EXISTING IT RM
122.31 SF
MOLEC BIO
286.38 SF
MICROBIO
286.38 SF
GEN LAB/DOC STOR
763.08 SF
IH/SAFETY STOR
207.33 SF
TRACE EVID
876.62 SF
MASS SPEC
812.64 SF
ANALY SMPL PREP
470.53 SF
AIR LOCK
92.93 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
144.07 SF
DEPARTMENT LEGEND
ADMINISTRATIVE SPACE
BUILDING SUPPORT
CIRCULATION
COMMON SPACE
LABORATORY (CLOSED)
LABORATORY (OPEN)
LABORATORY SUPPORT
OFFICE
ELECT REPAIR
207.33 SF
IT OFFICE
58.45 SF
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/
/2
9:
:2
A
M
LABORATORY LAYOUT - OPTION 1
F D
A F o re n si c C h em is tr y C e nt er
F C
C
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
Q-01
06/02/20
NOT TO SCALE1
01-A-FLOOR PLAN - EQUIPMENT - OPTION 1 - PREFERRED OPTION
1 CONCEPT DESIGN 06/11/20
MARK DESCRIPTION DATE
546.56 SF
EVID DEST
138.7 SF
EXIST IT RM
179.3 SF
CONF RM
252.24 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
132.26 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
CONF RM
252.24 SF
DATA RM
123.8 SF
DATA RM
131.86 SF
DATA RM
123.8 SF
PHOTO DOC
461.33 SF
ANALY SMPL PREP
463.75 SF
GLASSWASH
269.31 SF
GEN LAB/DOC STOR
763.08 SF
IH/SAFETY STOR
207.33 SF
MOLEC BIO
286.38 SF
MICROBIO
286.38 SF
NEW CHEM LAB
3567.65 SF
NEW SEP III LAB
2938.08 SF ANALY SMPL PREP
470.53 SF
TRACE EVID
876.62 SF
MASS SPEC
812.64 SF
AIR LOCK
92.93 SF
DEPARTMENT LEGEND
ADMINISTRATIVE SPACE
BUILDING SUPPORT
CIRCULATION
COMMON SPACE
LABORATORY (CLOSED)
LABORATORY (OPEN)
LABORATORY SUPPORT
ELECT REPAIR
207.33 SF
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:4
1:
P M
LABORATORY LAYOUT - OPTION 2
F D
A F o re n si c C h em is tr y C e nt er
F C
C
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
Q-02
06/03/20
NOT TO SCALE2
01-A-FLOOR PLAN - EQUIPMENT - OPTION 2
1 CONCEPT DESIGN 06/11/20
CHEM LAB & SEP III LAB
4213.19 SF
OPTION 3 FUTURE LAB SPACE
3073 SF
OPTION 3 FUTURE LAB SPACE
1765 SF
AIR LOCK
92.93 SF
TRACE EVID
876.62 SF
MASS SPEC
812.64 SF
ANALY SMPL PREP
470.53 SF
MOLEC BIO
286.38 SF
MICROBIO
286.38 SF
IH/SAFETY STOR
207.33 SF
GEN LAB/DOC STOR
763.08 SF
EXISTING IT RM
121.6 SF
LAB EQ STOR
482.99 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
EVID DEST
138.7 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
144.07 SF
PHOTO DOC
463.75 SF
ANALY PREP
463.75 SF GLASSWASH
269.31 SF
DEPARTMENT LEGEND
ADMINISTRATIVE SPACE
BUILDING SUPPORT
CIRCULATION
COMMON SPACE
LABORATORY (CLOSED)
LABORATORY (OPEN)
LABORATORY SUPPORT
OFFICE
ELECT REPAIR
207.33 SF
IT OFFICE
58.11 SF
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
16' 32' 64'
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
7/ 9/
:4
2:
P M
LABORATORY LAYOUT - OPTION 3
F D
A F o re n si c C h em is tr y C e nt er
F C
C
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
Q-03
06/03/20
NOT TO SCALE3
01-A-FLOOR PLAN - EQUIPMENT - OPTION 3
1 CONCEPT DESIGN 06/11/20
DATA RM
133.06 SF
DATA RM
144.07 SF LAB EQ STOR
482.99 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF
DATA RM
133.06 SF EVID DEST
138.7 SF
PHOTO DOC
463.75 SF
ANALY PREP
463.75 SF
GLASSWASH
266.9 SF
NEW CHEM LAB & SEP 3 LAB
6086.62 SF
EXISTING IT RM
122.31 SF
DEPARTMENT LEGEND
ADMINISTRATIVE SPACE
BUILDING SUPPORT
CIRCULATION
LABORATORY (CLOSED)
LABORATORY (OPEN)
LABORATORY SUPPORT
OFFICE
IT OFFICE
58.45 SF
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
FDA FORENSIC CHEMISTRY CENTER
6751 STEGER DRIVE
CINCINNATI OH 45237
11 x 17
HDR
RENOVATION AND ALTERATION
A/E CON. NO.
STEPHEN CARBERY
47PF0020C0015
OH0306ZZ
8' 16' 32'
7/
/2
9:
:3
A
M
LABORATORY CASEWORK LAYOUT - OPTION 1
F D
A F o re n si c C h em is tr y C e nt er
F C
C
HDR Architecture 30 West Monroe Street Suite 700 Chicago, IL 60603
Q-04
06/03/20
NOT TO SCALE4
01-A-FLOOR PLAN - EQUIPMENT - OPTION 1 APPENDIX - PREFERRED OPTION
1 CONCEPT DESIGN 06/11/20
546.56 SF
EVID DEST
138.7 SF
EXIST IT RM
179.3 SF
CONF RM
252.24 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
132.26 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
DATA RM
123.8 SF
CONF RM
252.24 SF
DATA RM
123.8 SF
DATA RM
131.86 SF
DATA RM
123.8 SF
PHOTO DOC
461.33 SF
ANALY SMPL PREP
463.75 SF
GLASSWASH
269.31 SF
NEW CHEM LAB
3567.65 SF
NEW SEP III LAB
2938.08 SF
DEPARTMENT LEGEND
ADMINISTRATIVE SPACE
BUILDING SUPPORT
LABORATORY (CLOSED)
LABORATORY (OPEN)
LABORATORY SUPPORT
TRUE NORTH
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BYDATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
FLOOR NO.
REVISION
TITLE
FOR OFFICIAL USE ONLY
UNITED STATES GOVERNMENT
PROPERTY OF THE
GREAT LAKES REGION 5 GENERAL SERVICES
ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU) - PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO…