FARM II Attachment L-6 Relevancy Matrix.xlsx
XLSX spreadsheet 38 KB Posted
- Attached to
- Facilities Acquisitions for Restoration and Modernization (FARM II) Federal contract opportunity
- Solicitation number
- DraftFA910121R0001
About this file
This document contains a draft request for proposal for facilities acquisition services. The draft RFP is for the Facilities Acquisitions for Restoration and Modernization II (FARM II) multiple award, indefinite-delivery/indefinite-quantity contract to provide mechanical, electrical, instrumentation, data, and control systems, and utilities design-build, construction projects, and two-phase design/build services for military ground testing facilities within the Arnold Engineering Development Complex. The proposed performance period is five years. Reviewers are requested to provide comments on the clarity of tasks to be completed, the evaluation criteria, and the completeness of proposal preparation instructions. The government intends to consider all feedback to finalize the solicitation and create a competitive procurement process. Questions regarding the draft RFP are due by April 30, 2021.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FARM ll FA910121R0001 DRFP Q and A 7May21.pdf | ||
| 3. FARM II Attachment 1 Statement of Work_Draft_9April2021.pdf | ||
| 7. FARM Il Attachment 8 Section L.pdf | ||
| PPI tool.zip | ZIP file | |
| 1. FARM ll DRFP Cover Letter.pdf | ||
| 4. FARM ll Attachment 2 Scheduled GFP.pdf | ||
| FARM II Attachment L-1 PPI Tool.pdf | ||
| 8. FARM II Attachment 9 Section M.pdf | ||
| 2. FARM ll Draft SF1442.pdf.pdf | ||
| 5. FARM ll Attachment 3 Wage Determination.pdf | ||
| 6. FARM II Attachment 7 Seed Project SOW.pdf | ||
| FARM ll Atch L-3 PPQ Cover Letter 9Apr21.pdf.pdf | ||
| FARM II Attachment L-5 Subcontractor Consent Letter.pdf | ||
| FARM II Atch L-2 Past and Present Performance Questionnaire.pdf | ||
| FARM II Attachment L-4 Client Authorization Letter.pdf | ||
| FARM II Attachment L-7 Pricing Sheet.xlsx | XLSX spreadsheet | |
| FARM ll FA910121R0001 DRFP Q and A.xlsx | XLSX spreadsheet |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Prime
| Name of Prime Contractor | Reference 1 | Reference 2 | Reference 3 | Reference 4 | Reference 5 | ||
| Management Subfactor | |||||||
| M-2.2.1.1.1. | Teaming and Subcontractor Management | ||||||
| M-2.2.1.1.2. | Quality Management System | ||||||
| M-2.2.1.1.3. | Qualified Personnel | ||||||
| Technical Capabilities (SOW 1.2) | |||||||
| Mechanical | |||||||
| M1 | Air duct, expansion joints, and control/process valves (≥ 36” Ø and 150 psig) | ||||||
| M2 | High pressure duct/piping & valves (typ. 4" to 8"Ø, ≥ 4000 psig) | ||||||
| M3 | Large pressure vessels (≥ 2000 psig; ≥ 10K gallons) | ||||||
| M4 | Desiccant bed air dryers (≤ 300 psia & ≥ 200 lb/s) | ||||||
| M5 | Turning vanes for large air ducting (up to 50-ft Ø; 0.5-160 psia) | ||||||
| M6 | Cooling water/raw water pumps (300-50,000 gpm; 30-4,000 hp), filters/strainers, control/process valves,and distribution lines (typ. 6” to 90” Ø) | ||||||
| M7 | Hydraulic systems with high flow and pressure requirements (20-200 gpm (typ. 2 pumps @ 100 gpm ea) and 2500 psig) | ||||||
| M8 | Large steam distribution systems (60 kpph boilers, and piping up to 14" Ø) | ||||||
| M9 | Chillers and refrigeration equipment (300-5000 refrigeration tons) | ||||||
| M10 | Large heat exchangers: air to air; water to air; shell and tube, etc. (∆T up to 325 °F) | ||||||
| Electrical | |||||||
| E1 | Interior & exterior lighting for industrial buildings | ||||||
| E2 | Medium voltage gas insulated switchgear (≤ 13.8kV) | ||||||
| E3 | Unit substations (typical 6.9/2.4kV) | ||||||
| E4 | Motor Control Centers (≤ 600V) | ||||||
| E5 | Transformers (≤ 161/13.8kV) | ||||||
| E6 | Uninterruptable Power Supply (UPS) | ||||||
| E7 | Ducting/vaults/ cables (13.8kV & 6.9kV) | ||||||
| E8 | Motor exciters | ||||||
| E9 | Oil circuit breakers (typical 3000 amp & 550kV BIL) | ||||||
| E10 | Power panels/conduit/wiring (≤ 480V) | ||||||
| E11 | Variable frequency drives for motors (≥ 600V & ≤ 69kV) | ||||||
| ID&C | |||||||
| I1 | PLC-based industrial control systems | ||||||
| I2 | High Speed (< 10ms Loop Time) facility control systems | ||||||
| I3 | Controls software development and modification | ||||||
| I4 | Secure control systems | ||||||
| I5 | Data logging system design and integration | ||||||
| I6 | Control systems instrumentation design and integration |
&"Times New Roman,Bold"ATTACHMENT L-6 RELEVANCY MATRIX &"Times New Roman,Regular"FARM II
FA9101-21-R-0001
Attachment 8
Partners
| Name of Partner (Subcontractor/Joint Venture) | Reference 1 | Reference 2 | Reference 3 | ||
| Management Subfactor | |||||
| M-2.2.1.1.1. | Teaming and Subcontractor Management | ||||
| M-2.2.1.1.2. | Quality Management System | ||||
| M-2.2.1.1.3. | Qualified Personnel | ||||
| Technical Capabilities (SOW 1.2) | |||||
| Mechanical | |||||
| M1 | Air duct, expansion joints, and control/process valves (≥ 36” Ø and 150 psig) | ||||
| M2 | High pressure duct/piping & valves (typ. 4" to 8"Ø, ≥ 4000 psig) | ||||
| M3 | Large pressure vessels (≥ 2000 psig; ≥ 10K gallons) | ||||
| M4 | Desiccant bed air dryers (≤ 300 psia & ≥ 200 lb/s) | ||||
| M5 | Turning vanes for large air ducting (up to 50-ft Ø; 0.5-160 psia) | ||||
| M6 | Cooling water/raw water pumps (300-50,000 gpm; 30-4,000 hp), filters/strainers, control/process valves,and distribution lines (typ. 6” to 90” Ø) | ||||
| M7 | Hydraulic systems with high flow and pressure requirements (20-200 gpm (typ. 2 pumps @ 100 gpm ea) and 2500 psig) | ||||
| M8 | Large steam distribution systems (60 kpph boilers, and piping up to 14" Ø) | ||||
| M9 | Chillers and refrigeration equipment (300-5000 refrigeration tons) | ||||
| M10 | Large heat exchangers: air to air; water to air; shell and tube, etc. (∆T up to 325 °F) | ||||
| Electrical | |||||
| E1 | Interior & exterior lighting for industrial buildings | ||||
| E2 | Medium voltage gas insulated switchgear (≤ 13.8kV) | ||||
| E3 | Unit substations (typical 6.9/2.4kV) | ||||
| E4 | Motor Control Centers (≤ 600V) | ||||
| E5 | Transformers (≤ 161/13.8kV) | ||||
| E6 | Uninterruptable Power Supply (UPS) | ||||
| E7 | Ducting/vaults/ cables (13.8kV & 6.9kV) | ||||
| E8 | Motor exciters | ||||
| E9 | Oil circuit breakers (typical 3000 amp & 550kV BIL) | ||||
| E10 | Power panels/conduit/wiring (≤ 480V) | ||||
| E11 | Variable frequency drives for motors (≥ 600V & ≤ 69kV) | ||||
| ID&C | |||||
| I1 | PLC-based industrial control systems | ||||
| I2 | High Speed (< 10ms Loop Time) facility control systems | ||||
| I3 | Controls software development and modification | ||||
| I4 | Secure control systems | ||||
| I5 | Data logging system design and integration | ||||
| I6 | Control systems instrumentation design and integration |
&"Times New Roman,Bold"ATTACHMENT L-6 RELEVANCY MATRIX &"Times New Roman,Regular"FARM II
FA9101-21-R-0001
Attachment 8