Simulator Common Architecture Requirements and Standards – SCARS Task Order 001 PWS
21 December 2018
Task Order #1 - Performance Work Statement (PWS)
RFP NO: FA8621-18-R-0002
Prepared For:
Department of the Air Force Air Force Life Cycle Management Center AFLCMC/WNS Wright-Patterson AFB Dayton, Ohio 45433
Distribution A. Approved for public release: distribution unlimited
1. GENERAL INFORMATION 1
Where applicable, each section of this Performance Work Statement (PWS) is followed 2 by a list of the relevant Contract Data Requirements Lists (CDRLs) to provide 3 traceability between described tasks and contract deliverables. 4 Terms such as SCARS Prime, Affiliates, and Partners are defined in this document in 6 accordance with (IAW) SCARS IDIQ PWS Para 1.2. 7
1.1. Task Order Scope 8
This task order includes the following activities and products: 9
1) Post Award Conference 11
2) Initial Design and Documentation of the Simulator Common Architecture (SCA) 12 to include Reference Architecture Services 13
3) Standup and operation of the Temporary Security Operations Center (SOC) 14 Contractor Facility (SOC equipment, software, and SCARS Library) 15
4) Standup and installation of SCARS On-Premise Equipment (OPE) at sites 16 designated by the Government in this Task Order. For this Task Order there will 17 be a total of four CONUS sites, all of which will have an existing network 18 connection to a SCARS Partner. The specific sites will be provided upon contract 19 award. 20
5) Standup and operation of the SCARS Library 21
6) Cyber Secure Operating Systems (OS) Services 22
7) Operations 23
8) Management Services And Software Annual Management Services required for 24 execution of SCARS Prime responsibilities (general management services, 25 secretariat of the SCARS Engineering Capabilities Board (SECB), etc.) not 26 strictly related to SCARS Increment One 27
9) Product Support 28
2. Post Award Conference (CLIN 0001) 29
The SCARS Prime shall host a post award conference at a SCARS Prime facility in 30 accordance with IDIQ PWS Para 6.11.1 within 30 calendar days of task order award. 31 o A001 - CDRL - Conference Agenda (DI-ADMN-81249B) 32 o A002 - CDRL - Conference Minutes (DI-ADMN-81250B/T) 33 o A003 - CDRL - Presentation Materials (DI-ADMN-81373) 34
3. Preparatory Services (Non-Recurring Engineering) 35
(CLIN 0017) 36
3.1. Initial SCA Baseline 37
The SCARS Prime shall use systems engineering processes to establish the 38 Government’s technical baseline and equipment for the SCA in accordance with the 39 IDIQ PWS and Systems Requirements Document (SRD). 40
The SCARS Prime shall architect and maintain the SCA, SOC and Library and the 41 execution of SCARS Management Services IAW IDIQ PWS Para 4.2.1 and SCA Open 42 System Requirements IAW IDIQ PWS Section 4.6. These preparatory services shall 43 include all engineering services and security services necessary to design and establish 44 SCARS infrastructure which has the ability to support the SCARS sites that will be 45 identified by the Government upon contract award. The first four initial sites covered 46 under this Task Order will be CONUS and have an existing network connection through 47 a SCARS Partner. 48 o A020 - CDRL - Open Systems Management Plan (DI-MGMT-82099) 49 o A029 - CDRL - System/Subsystem Design Description (SSDD) (DI-IPSC-50
81432A/T) 51 [SUBTITLE: MBSE System Model] 52 o A079 - CDRL - Safety Assessment Report (SAR) (DI-SAFT-80102C) 53 o A080 - CDRL - System Safety Program Plan (SSPP) (DI-SAFT-81626/T) 54
Note: Existing network connection equipment and routing services will be provided to 56 the Temporary SOC location by the Government and will be procured by the 57 Government using existing contractual vehicles. 58
The SCARS Prime shall procure, deliver, set up, and test the SCARS OPE and network 59 connection at the first SCARS Site IAW IDIQ PWS Paras 4.2.4 and 4.3.5. 60 o A018 - CDRL - Interface Design Description (IDD) (DI-IPSC-81436A) 61 o A023 - CDRL - Software Design Description (SDD) (DI-IPSC-81435A) 62 o A027 - CDRL - Software Version Description (SVD) (DI-IPSC-81442A/T) 63 o A029 - CDRL - System/Subsystem Design Description (SSDD) (DI-IPSC-64
81432A/T) 65 [SUBTITLE: MBSE System Model] 66 o A031 - CDRL - Test Plan (DI-NDTI-80566A) 67 o A032 - CDRL - Test Procedures (DI-NDTI-80603A) 68
[SUBTITLE: Acceptance Test Procedures] 69
The SCARS Prime shall define and present the design of the Help Desk operations to 70 meet the tasks described in IDIQ PWS Para 5.5, which will be implemented in a future 71 task order. 72
The SCARS Prime shall define and present the operational approach to accomplish 73 Assess and Authorize Support Services IAW IDIQ PWS Para 5.6, which will be 74 implemented in a future task order. 75 o A017 - CDRL - DoD Risk Management Framework (RMF) Package Deliverables 76
(DI-MGMT-82001/T) 77
o A048 - CDRL - Risk Management Status Report (DI-MGMT-81809/T) 78
The SCARS Prime shall identify Critical Program Information (CPI) generated and 80 inherited which will reside on the SCA IAW PWS Para 6.7.6. The SCARS Prime shall 81 assist in the Government generation of a Program Protection Plan (PPP) annex to the 82 Enterprise Life Cycle Strategy (ELCS). 83 o A001 - CDRL - Conference Agenda (DI-ADMN-81249B) 84 o A002 - CDRL - Conference Minutes (DI-ADMN-81250B/T) 85 o A003 - CDRL - Presentation Materials (DI-ADMN-81373) 86
The SCARS Prime shall fully document SCARS Increment One IAW PWS Paras 3, 3.1, 88 and 3.2. SCARS Increment One shall be defined as the hardware/software (HW/SW) 89 required to execute remote scanning utilizing Assured Compliance Assessment Solution 90 (ACAS) software, Government approved standards, and any additional applications, 91 services, and/or microservices for SCA operations. The SCARS Prime shall submit 92 standard(s) to support Increment One for Government approval through the SECB 93 process. The SCARS Prime shall establish an Increment Deployment Plan. The 94 Increment Deployment Plan shall include proposed capabilities and inheritable Risk 95 Management Framework (RMF) Control Correlation Identifiers (CCIs) for consideration 96 by the SECB. 97 o A001 - CDRL - Conference Agenda (DI-ADMN-81249B) 99 o A002 - CDRL - Conference Minutes (DI-ADMN-81250B/T) 100 o A003 - CDRL - Presentation Materials (DI-ADMN-81373) 101 o A005 - CDRL - Management Plan (DI-MGMT-80004A) 102
[SUBTITLE: Increment Deployment Plan] 103 o A018 - CDRL - Interface Design Description (IDD) (DI-IPSC-81436A) 104 o A023 - CDRL - Software Design Description (SDD) (DI-IPSC-81435A) 105 o A024 - CDRL - Software Development Plan (SDP) (DI-IPSC-81427B) 106 o A025 - CDRL - Software Installation Plan (SIP) (DI-IPSC-81428A) 107
[SUBTITLE: Increment Deployment Plan] 108 o A026 - CDRL - Software Product Specification (SPS) (DI-IPSC-81441A) 109 o A027 - CDRL - Software Version Description (SVD) (DI-IPSC-81442A/T) 110 o A029 - CDRL - System/Subsystem Design Description (SSDD) (DI-IPSC-111
81432A/T) 112 [SUBTITLE: MBSE System Model] 113 o A046 - CDRL - Database Design Description (DBDD) (DI-IPSC-81437A) 114 o A049 - CDRL - Software Requirements Specification (SRS) (DI-IPSC-81433A) 115
The SCARS Prime shall document the SCA in a Reference Architecture IAW IDIQ PWS 117 Para 4.2 (CLIN 0017). The SCARS Prime shall plan incremental updates to the SCA 118 IAW IDIQ PWS Para 4.2. The SCARS Prime shall deliver COTS and GOTS equipment 119 and software to the Government IAW IDIQ PWS Para 4.2 120 o A007 - CDRL - Supplier’s Configuration Management Plan (DI-SESS-80858C) 122 The SCARS Prime shall execute and deliver the Reference Architecture Services in the 124 amount of 6000 hours IAW PWS Paras 4.7, 4.7.1, 4.7.2, and 4.7.3 (CLIN 0016). The 125 expected expansion of the Reference Architecture shall include: 126
• The following DoD Architecture Framework (DoDAF) views: 127 o SV-1 Systems Interface Description 128 o SV-2 Systems Resource Flow Description 129 o SV-4 Systems Functionality Description 130 o SV-5a Operational Activity to Systems Function Traceability Matrix 131 o SV-5b Operational Activity to Systems Traceability Matrix 132 o SV-6 Systems Resource Flow Matrix 133 o SV-7 Systems Measures Matrix 134 o SV-8 Systems Evolution Description 135 o SV-9 Systems Technology & Skills Forecast 136 o Div1 Conceptual Data Model 137 o Div2 Logical Data Model 138 o Div3 Physical Data Model 139 o DM2 Meta Model 140 o CV-2 Capability Taxonomy 141 o CV-3 Capability Phasing 142 o CV-6 Capability to Operational Activities Mapping 143 o SvcV-8 Services Evolution Description 144 o StdV-1 Standards Profile 145 o StdV-2 Standards Forecast 146 o OV-1 High-Level Operational Concept Graphic 147 o OV-2 Operational Resource Flow Description 148 o OV-4 Organizational Relationships Chart 149 o OV-5a Operational Activity Decomposition Tree 150 o OV-5b Operational Activity Model 151 o OV-6C Event-Trace Description 152 o AV-1 All Viewpoint Overview and Summary Information 153 o AV-2 Integrated Dictionary 154 o PV-2 Project Timelines 155 o PV-3 Project to Capability Mapping 156
• An inclusion of the SCA design in the MBSE system model 157
• Requirements traceability between the SCARS requirements and MBSE system 158 model using digital engineering tools 159
• Additional views and expansion as directed by the SECB 160
The SCARS Prime shall define and document the SCA in a Reference Architecture 161 defined by standards approved through the SCARS Standards Management Process 162 (SMP) and SECB. The SCARS Prime shall deliver all Commercial Off the Shelf (COTS) 163 and Government Off the Shelf (GOTS) equipment and software to the Government, with 164 data rights as required by the H-clauses. 165 o A020 - CDRL - Open Systems Management Plan (DI-MGMT-82099) 166 o A029 - CDRL - System/Subsystem Design Description (SSDD) (DI-IPSC-167
81432A/T) 168 [SUBTITLE: MBSE System Model] 169 o A062 - CDRL - Technical Data Package (DI-SESS-80776A/T) 170 The SCARS Prime shall accomplish Site Survey and Installation Planning Services in 172 accordance with IDIQ PWS Para 4.3.1 (CLIN 0002). 173 o A022 - CDRL - Site Survey Report (SSR) (DI-MISC-82104) 174
Note: Future SCARS Increments will be identified in future task orders as they are 175 developed through the SECB process. It is possible that implementation of SCARS 176 Increment One at a specific site will also include the implementation of those future 177 increments as the Increment One rollout to SCARS sites is occurring due to the length 178 of time it may take to implement Increment One at all SCARS sites.. 179
3.2. Initial SCARS Security Operations Center (SOC) 180
The SCARS Prime shall provide the preparatory services necessary to design, deliver, 181 and maintain a SOC at a SCARS Prime’s facility at a CONUS location IAW IDIQ PWS 182 Para 4.2.3 and as specified in this Task Order. The SOC shall be designed, delivered, 183 and maintained at UNCLASSIFIED and SECRET classification levels. These 184 preparatory services shall include all engineering services and security services 185 necessary to design, establish and demonstrate SCARS infrastructure which has the 186 capacity to support a minimum of 60 SCARS sites within 1 year of standup. The SOC 187 shall demonstrate the architecture’s ability to scale to 120 sites and 180 sites which are 188 the anticipated required support for year 2 and 3 respectively. The SOC shall stand up 189 within 180 calendar days of the award of this Task Order. 190 o A018 - CDRL - Interface Design Description (IDD) (DI-IPSC-81436A) 192 A023 - CDRL - Software Design Description (SDD) (DI-IPSC-81435A) 193 o A027 - CDRL - Software Version Description (SVD) (DI-IPSC-81442A/T) 194 o A029 - CDRL - System/Subsystem Design Description (SSDD) (DI-IPSC-195
81432A/T) 196 [SUBTITLE: MBSE System Model] 197
The SCARS Prime shall provide the preparatory services necessary to design, deliver, 199 and maintain the SOC Baseline Recovery IAW IDIQ PWS Para 4.2.7 and the SCARS 200 SRD Para 3.3.10. 201 o A018 - CDRL - Interface Design Description (IDD) (DI-IPSC-81436A) 202 o A023 - CDRL - Software Design Description (SDD) (DI-IPSC-81435A) 203 o A027 - CDRL - Software Version Description (SVD) (DI-IPSC-81442A/T) 204 o A029 - CDRL - System/Subsystem Design Description (SSDD) (DI-IPSC-205
81432A/T) 206 [SUBTITLE: MBSE System Model] 207
The SCARS Prime shall provide the preparatory services necessary to design, deliver, 209 and maintain the Software Baseline Recovery Units (SBRUs) IAW IDIQ PWS Para 4.2.8 210 and the SCARS SRD Para 3.9. 211 o A018 - CDRL - Interface Design Description (IDD) (DI-IPSC-81436A) 212 o A023 - CDRL - Software Design Description (SDD) (DI-IPSC-81435A) 213 o A027 - CDRL - Software Version Description (SVD) (DI-IPSC-81442A/T) 214 o A029 - CDRL - System/Subsystem Design Description (SSDD) (DI-IPSC-215
81432A/T) 216 [SUBTITLE: MBSE System Model] 217
The SCARS Prime shall define the procedures for connecting to the SOC, conducting 219 remote scanning, and reporting the results to support the ATO process of SCARS 220 Affiliate training systems IAW IDIQ PWS Para 5.3. 221 The SCARS Prime shall define and publish all processes required to operate the SOC 223 in a SCARS standard to include: 224
• Internal operating procedures 225
• Requirements and processes for SCARS site connection 226
• Scheduling events and library access instances 227
• Library archiving and removal 228
• Remote scan execution, reporting, re-scan, and adding additional 229 functions/scanning requirements 230
• OCI related protections 231
• Backup, restore and storage 232
• User Credential Management for SOC and OPE 233
• Certification documentation and information 234 o A082 - CDRL - Scientific and Technical Reports (DI-MISC-80711A/T) 236 [SUBTITLE: SCARS SOC Processes and Operating Procedures] 237
The SCARS Prime shall act as the system administrator for SCARS equipment. 239
The SCARS Prime shall provide the preparatory services necessary to architect, 240 deliver, and maintain a Library at the UNCLASSIFIED and SECRET security levels with 241 the purpose of storing and distributing applications and providing access to SCARS 242 related information/documentation executed in accordance with IDIQ PWS Para 5.2. 243 The Library capability with ACAS plugins, Operating System Images, and SCA 244 applications necessary to support Increment One shall be operational no later than six 245
(6) months after task order award. 246 o A006 - CDRL - Contractor’s Data Management Plan (CDMP) (DI-MGMT-82228) 247 The SCARS Prime shall develop and deliver a Facilities Requirements document IAW 249 IDIQ PWS Para 5.9.8. 250 o A086 - CDRL - Facilities Requirements Document (FRD) (DI-MGMT-81836) 252
4. Simulator Common Architecture (SCA) Equipment 255 and Services 256
4.1. OPE Site Survey (CLIN 0002) 257
The SCARS Prime shall execute and deliver site surveys IAW IDIQ PWS Para 4.3.1 at 258 four (4) CONUS Locations at the SECRET classification. The specific 4 sites will be 259 specified upon contract award, and will have existing SCARS Partner WAN connectivity. 260 o A022 - CDRL - Site Survey Report (SSR) (DI-MISC-82104) 261
4.2. OPE and Software (CLIN 0007) 262
The SCARS Prime shall define, design, deliver, deploy, and sustain OPE and software 263 IAW IDIQ PWS Paras 4.2.4 and 4.3.5 to the four (4) CONUS Locations at the SECRET 264 classification level. The SCARS Prime shall provide SCARS Partners OPEs as 265 necessary to support recurring integration/regression testing with SCARS Partner 266 systems. The SCARS Prime shall deliver and maintain both an operational mode and a 267 development mode as defined in SRD Paras 3.7.4 through 3.7.7. 268
The SCARS Prime shall work with the SCARS Affiliates, SCARS Partners, and the host 269 base as required to install and integrate the OPE. 270
The SCARS Prime shall define, design, deliver, deploy, and sustain SBRUs 271 representative of each OPE software configuration. The SCARS Prime shall ensure that 272 the SBRUs can remotely restore the OPE software configurations from a centrally 273 managed location. The SCARS Prime shall also provide on-site SBRUs with the OPE to 274 enable local recovery of the OPE. 275 o A018 - CDRL - Interface Design Description (IDD) (DI-IPSC-81436A) 276 o A023 - CDRL - Software Design Description (SDD) (DI-IPSC-81435A) 277 o A027 - CDRL - Software Version Description (SVD) (DI-IPSC-81442A/T) 278 o A029 - CDRL - System/Subsystem Design Description (SSDD) (DI-IPSC-279 81432A/T) 280 [SUBTITLE: MBSE System Model] 281 o A031 - CDRL - Test Plan (DI-NDTI-80566A) 282 o A032 - CDRL - Test Procedures (DI-NDTI-80603A) 283
[SUBTITLE: Acceptance Test Procedures] 284
4.3. SOC Equipment and Software (CLIN 0005) 286
The SCARS Prime shall define, design, deliver, deploy, and sustain SOC equipment 287 and software IAW IDIQ PWS Para 4.2.3 to support the four (4) CONUS Locations at the 288 SECRET classification level. 289 o A018 - CDRL - Interface Design Description (IDD) (DI-IPSC-81436A) 291 o A023 - CDRL - Software Design Description (SDD) (DI-IPSC-81435A) 292 o A027 - CDRL - Software Version Description (SVD) (DI-IPSC-81442A/T) 293 o A029 - CDRL - System/Subsystem Design Description (SSDD) (DI-IPSC-294
81432A/T) 295 [SUBTITLE: MBSE System Model] 296
The SCARS Prime shall install and configure the SOC equipment and software to 298 establish a SOC that supports the four (4) CONUS locations at the SECRET 299 classification level IAW IDIQ PWS Para 4.3.3. and this task order. The SCARS Prime 300 shall create and deliver test procedures to the Government. The SCARS Prime shall 301 create a test plan for the testing of the SOC equipment and software. 302 o A031 - CDRL - Test Plan (DI-NDTI-80566A) 304 o A032 - CDRL - Test Procedures (DI-NDTI-80603A) 305
[SUBTITLE: Acceptance Test Procedures] 306
5. Temporary SOC Contractor Facility (CLIN 0005 & 309
CLIN 0012) 310
The SCARS Prime shall stand up a Temporary SOC facility at a CONUS location IAW 311 IDIQ PWS Paras 5.9.1 - 5.9.3 and 5.9.7. 312 o A017 - CDRL - DoD Risk Management Framework (RMF) Package Deliverables 314
(DI-MGMT-82001/T) 315
The SCARS Prime shall conduct SOC operations after SOC stand up IAW PWS Paras 317 5, 5.1, 5.1.1, 5.1.2, 5.4, 5.6. 318 o A017 - CDRL - DoD Risk Management Framework (RMF) Package Deliverables 320
(DI-MGMT-82001/T) 321
o A048 - CDRL - Risk Management Status Report (DI-MGMT-81809/T) 322
The SCARS Prime shall conduct SCARS Library Services IAW with PWS Para 5.2. 324 o A006 - CDRL - Contractor’s Data Management Plan (CDMP) (DI-MGMT-82228) 326
6. Cyber Secure Operating Systems (OS) Services (CLIN 328
0024) 329
The SCARS Prime shall define, design, deliver, deploy, and sustain common OS 330 images in accordance with SCARS IDIQ PWS Para 6.3 and SRD Paras 3.14.1-3.14.2 331 within six (6) months of Task Order award. 332 o A017 - CDRL - DoD Risk Management Framework (RMF) Package Deliverables 333
(DI-MGMT-82001/T) 334
7. Operations (CLIN 0012) 335
The SCARS Prime shall be responsible for operating a SOC to: assess and achieve 336 Risk Management Framework (RMF) controls; provide cybersecurity services and 337 network services to SCARS sites; manage SCA; manage the Library; provide support 338 services and execute SCARS events up to the SECRET level for systems with OPE. 339
The SCARS Prime shall restrict the processing and storage of data gathered through 340 SCARS events to the SOC facility, required Government reporting tools and systems 341 (such as eMASS), and on-site SCA equipment. 342 The SCARS Prime shall develop a contingency plan for the system IAW NIST SP 800-344 34, “Contingency Planning (CP) Guide for Federal Information Systems” and use the 345 “Contingency Planning: Low Impact System Template” IAW IDIQ PWS Para 5.9.7. The 346 Contingency Plan shall meet requirements of the CP security family from NIST SP 800-347
53. 348
The SCARS Prime shall develop an Incident Response Plan IAW PWS IDIQ Para 5.9.7 349 and NIST SP 800-61 that shall also meet requirements of the Incident Response 350 security control family from NIST SP 800-53. 351 o A017 - CDRL - DoD Risk Management Framework (RMF) Package Deliverables 352
(DI-MGMT-82001/T) 353
8. Management Services And Software (CLIN 0023) 354
8.1. Recurring Management Tasks 355
The SCARS Prime shall execute and deliver Management Services and Software in 356 accordance with the IDIQ PWS and SRD at 4 sites at the SECRET and 357 UNCLASSIFIED level. 358
The SCARS Prime shall establish ACAs with up to twenty (20) SCARS Affiliates and 360 Partners for the purpose of facilitating SECBs. 361
The SCARS Prime shall accomplish Management Services and Software tasks at the 362 SECRET and UNCLASSIFIED classification IAW the requirements in the following 363 sections of the IDIQ PWS: 364
• 1.3 Contractor Personnel 365
• 5.7 Cybersecurity Contractor Training and Certification 366
• 5.8 Network Access Requirements 367
• 6.1 Establish and Execute Agreements 368
• 6.2 Stakeholder Collaboration Website 369
• 6.4 Manage and Maintain Standards 370
• 6.5 Standards Deployment Support Services 371
• 6.6 Testing 372
• 6.7 System Security 373
• 6.8 Configuration Management 374
• 6.9 Schedule Management 375
• 6.10 Risk Management 376
• 6.11.2 PMRs and TIMs 377
• 6.12 Perform Technical Development Reviews 378
• 6.13 Systems Engineering 379
• 6.14 Organizational Conflict of Interest (OCI) 380
• 6.15 Government Reviews 381
• 6.16 Financial Reporting 382
• 6.17 Contractor Manpower Reporting 383
• 6.20 Travel 384
The SCARS Prime shall provide the following CDRLs as necessary to support the 386 requirements in this Task Order. 387 o A001 - CDRL - Conference Agenda (DI-ADMN-81249B) 389 o A002 - CDRL - Conference Minutes (DI-ADMN-81250B/T) 390 o A003 - CDRL - Presentation Materials (DI-ADMN-81373) 391 o A004 - CDRL - Contract Change Proposal (CCPS) (DI-ADMN-81401B/T) 392 o A007 - CDRL - Supplier’s Configuration Management Plan (DI-SESS-80858C) 393 o A008 - CDRL - Configuration Status Accounting (CSA) Information (DI-SESS-394
81253C) 395 o A009 - CDRL - Configuration Audit Plan (DI-SESS-81646B) 396 o A010 - CDRL - Data Accession List (DI-MGMT-81453B/T) 397 o A011 - CDRL - Deficiency Report (DR) (DI-PSSS-81535A) 398 o A012 - CDRL - Contract Funds Status Report (CFSR) (DI-MGMT-81468) 399 o A013 - CDRL - Contract Work Breakdown Structure (DI-MGMT-81334D) 400 o A014 - CDRL - Software Resources Data Reporting: Development, Maintenance 401 and Enterprise Resource Planning Development Reports, and Data Dictionary 402
(DI- MGMT-82035A) 403
[SUBTITLE: Software Development Report (DD Form 3026-1)] 404 o A015 - CDRL - Software Resources Data Reporting: Development, Maintenance 405 and Enterprise Resource Planning Development Reports, and Data Dictionary 406
(DI- MGMT-82035A) 407
[SUBTITLE: Software Maintenance Report (DD Form 3026-2)] 408 o A016 - CDRL - Design Review Information Package (DRIP) (DI-SESS-81757A/T) 409 o A017 - CDRL - DoD Risk Management Framework (RMF) Package Deliverables 410
(DI-MGMT-82001/T) 411
o A018 - CDRL - Interface Design Description (IDD) (DI-IPSC-81436A) 412 o A019 - CDRL - Key and Certificate Management Plan (KCMP) (DI-MISC-413
81688A) 414 o A021 - CDRL - Quality Assurance Program Plan (DI-QCIC-81794) 415 o A023 - CDRL - Software Design Description (SDD) (DI-IPSC-81435A) 416 o A024 - CDRL - Software Development Plan (SDP) (DI-IPSC-81427B) 417 o A026 - CDRL - Software Product Specification (SPS) (DI-IPSC-81441A) 418 o A027 - CDRL - Software Version Description (SVD) (DI-IPSC-81442A/T) 419 o A028 - CDRL - Systems Engineering Management Plan (SEMP) (DI-SESS-420
81785A) 421 o A029 - CDRL - System/Subsystem Design Description (SSDD) (DI-IPSC-422
81432A/T) 423 [SUBTITLE: MBSE System Model] 424 o A030 - CDRL - Test/Inspection Report (DI-NDTI-80809B) 425 o A032 - CDRL - Test Procedure (DI-NDTI-80603A) 426
[SUBTITLE: Acceptance Test Procedures] 427 o A033 - CDRL - Joint Special Access Program Implementation Guide (JSIG) 428
System Authorization Package (SAP) (DI-ADMN-81969) 429 o A034 - CDRL - Integrated Program Management Report (IPMR) (DI-MGMT 430
81861A/T) 431 [SUBTITLE: Integrated Master Schedule/Contractor Performance Report] 432 o A046 - CDRL - Database Design Description (DBDD) (DI-IPSC-81437A) 433 o A047 - CDRL - Requirements Traceability Verification Matrix (DI-MGMT-82133) 434 o A048 - CDRL - Risk Management Status Report (DI-MGMT-81809/T) 435 o A050 - CDRL - System/Subsystem Specification (SSS) (DI-IPSC-81431A/T) 436 o A059 - CDRL - Engineering Change Proposal (ECP) (DI-SESS-80639D/T) 437 o A060 - CDRL - Notice of Revision (NOR) (DI-SESS-80642D) 438 o A061 - CDRL - Request for Variance (RFV) (DI-SESS-80640D) 439 o A063 - CDRL - Software Sustainability Package (DI-IPSC-82134) 440 [SUBTITLE: Support Software] 441 o A074 - CDRL - Program Protection Implementation Plan (PPIP) (DI-ADMN-442
81306/T) 443 o A083 - CDRL - Scientific and Technical Reports (DI-MISC-80711A/T) 444
[SUBTITLE: SCARS Certification Standards] 445 o A084 - CDRL - Scientific and Technical Reports (DI-MISC-80711A/T) 446
[SUBTITLE: Information Support Plan (ISP)] 447 o A085 - CDRL - Management Plan (DI-MGMT-80004A/T) 448
[SUBTITLE: Organizational Conflict of Interest (OCI) Mitigation Plan] 449 o A087 - CDRL - Software License Requirements List (DI-PSSS-82046) 450
8.2. Product Support 452
The SCARS Prime shall accomplish all Product Support tasks IAW the requirements in 453 the following paragraphs in Section 6 of the IDIQ PWS: 454 o 6.18.1. Product Support Logistics 456 o 6.18.1.1. Maintenance Planning and Management 457 o 6.18.1.2. Product Support Meetings and Communications 458 o 6.18.2. Supply Support 459 o 6.18.2.1. Inventory Management 460 o 6.18.2.2. Logistics Spares Package and Parts List 461 o 6.18.2.4. Supply Chain Risk Management 462 o 6.18.2.5. Counterfeit Part Prevention Program 463 o 6.18.2.6. Diminishing Manufacturing Sources and Material Shortages 464
Management Program 465 o 6.18.3. Item Unique Identification 466 o 6.18.7. Packaging, Handling, Storage and Transportation Services 467 o 6.18.8. Data 468 o 6.18.8.1. Data Rights 469 o 6.18.8.2 Engineering Data Updates and Revisions 470 o 6.18.8.3. Technical Data Package 471 o 6.18.9 Facilities and Infrastructure 472 o 6.18.10 Educational Information & Training Materials 473 o 6.18.11. Warranty 474
IAW IDIQ PWS 6.18.10, the SCARS Prime shall provide educational and training 476 materials for the Affiliates to operate the OPE. 477
The SCARS Prime shall provide the following CDRLs to support the requirements in this 478 Task Order. 479 o A001 - CDRL - Conference Agenda (DI-ADMN-81249) 480 o A002 - CDRL - Conference Minutes (DI-ADMN-81250A) 481 o A003 - CDRL - Presentation Materials (DI-ADMN-81373/T) 482 o A011 - CDRL - Deficiency Report (DR) (DI-PSSS-81535A) 483 o A028 - CDRL - Systems Engineering Management Plan (SEMP) (DI-SESS-484
81785A) 485 o A035 - CDRL - Logistics Plan (DI-SESS-82178/T) 486 o A036 - CDRL - Depot Maintenance Study (DI-ILSS-80739) 487 o A037 - CDRL - Distribution of Department of Defense (DoD) Depot Maintenance 488
Workload (50/50) Report (DI-MGMT-81749B) 489 o A038 - CDRL - Government Furnished Property Inventory and Forecasting 490
Report (DI-MGMT-81947B) 491 [SUBTITLE: Contractor Sustainment Report] 492 o A039 - CDRL - Government Industry Data Exchange Program (GIDEP) Alert 493 Response (DI-QCIC-80126B) 494 o A040 - CDRL - Government Industry Data Exchange Program (GIDEP) 495 Alert/Safe-Alert Report (DI-QCIC-80125B) 496 o A041 - CDRL - Government Property Inventory Report (DI-MGMT-80441C) 497 o A042 - CDRL - Item Unique Identification (IUID) Marking Activity, Validation and 498
Verification Report (DI-MGMT-81804A) 499 o A043 - CDRL - Item Unique Identification (IUID) Marking Plan (DI-MGMT-81803) 500 o A044 - CDRL - Physical Inventories Report (DI-MGMT-80259) 501 o A051 - CDRL - Training Device Inventory Checklist / Record (ICL/R) (DI-MISC-502
81191B) 503 o A052 - CDRL - Counterfeit Prevention Plan (DI-MISC-81832) 504 o A053 - CDRL - Contractor’s Progress and Status Report (DI-MGMT-81928/T) 505 o A054 - CDRL - Contract Field Service Report (DI-MGMT-81238/T) 506 o A055 - CDRL - Proposed Spares Parts List (DI-PSSS-80134) 507 o A056 - CDRL - Maintenance Test and Support Equipment Requirements List (DI-508
SESS-80294B/T) 509
o A057 - CDRL - Technical Manual Contract Requirements (TMCR) (TM-86-510
01Q/T) 511 o A058 - CDRL - Interim Contractor Support (ICS) Parts Usage and Maintenance 512
Data Collection Report (DI-ILSS-81226) 513 o A062 - CDRL - Technical Data Package (DI-SESS-80776A/T) 514 o A063 - CDRL - Software Sustainability Package (DI-IPSC-82134) 515
[SUBTITLE: Support Software] 516 o A064 - CDRL - Revisions to Existing Government Documents (DI-ADMN-517
80925A) 518 o A065 - CDRL - Parts Management Plan (DI-SDMP-81748) 519 o A066 - CDRL - Preservation and Packing Data (DI-PACK-80120C) 520 o A067 - CDRL - Special Packaging Instructions (SPI) (DI-PACK-80121C) 521 o A068 - CDRL - Status of Government Furnished Equipment (GFE) Report (DI-522
MGMT-80269) 523
o A069 - CDRL - Technical Manual (TM) Contractor Furnished Equipment (CFE) 524
Notice (DI-TMSS-80067C) 525 o A070 - CDRL - Technical Manual Book Plan (DI-TMSS-81813A) 526 o A071 - CDRL - Warranty Performance Report (DI-SESS-81639A) 527 o A072 - CDRL - Corrosion Prevention and Control Plan (DI-MFFP-81403A) 528 o A073 - CDRL - Government Furnished Equipment Detail Transaction Status Data 529
(DI-MGMT-80377/T) 530
o A077 - CDRL - Report, Record of Meeting Minutes (DI-ADMN-81505/T) 531 o A078 - CDRL - Scientific and Technical Reports (DI-MISC-80711A) 532
[SUBTITLE: Supply Chain Risk Management (SCRM)] 533
8.3. Small Business Participation 534
The SCARS Prime shall be responsible for meeting the Small Business Participation 535 requirement of no less than 15% of the total value of this task order. The SCARS Prime 536 shall submit a Small Business Participation Commitment Document (SBPCD) that will 537 be attached to Section J of the task order. The SBPCD shall include the small business 538 entities to be utilized, the products/services to be provided, and the extent of utilization 539 quantitatively (dollars and percentage) by small business subcontractor(s). 540
| 1. GENERAL INFORMATION |
| 1.1. Task Order Scope |
| 2. Post Award Conference (CLIN 0001) |
| 3. Preparatory Services (Non-Recurring Engineering) (CLIN 0017) |
| 3.1. Initial SCA Baseline |
| 3.2. Initial SCARS Security Operations Center (SOC) |
| 4. Simulator Common Architecture (SCA) Equipment and Services |
| 4.1. OPE Site Survey (CLIN 0002) |
| 4.2. OPE and Software (CLIN 0007) |
| 4.3. SOC Equipment and Software (CLIN 0005) |
| 5. Temporary SOC Contractor Facility (CLIN 0005 & CLIN 0012) |
| 6. Cyber Secure Operating Systems (OS) Services (CLIN 0024) |
| 7. Operations (CLIN 0012) |
| 8. Management Services And Software (CLIN 0023) |
| 8.1. Recurring Management Tasks |
| 8.2. Product Support |
| 8.3. Small Business Participation |
File details come from the government source that posted it.