Question Set 9 Responses.pdf
PDF 656 KB Posted
- Attached to
- FA8604 Storage Aids System/Niagara Falls ARS, New York MMHS Federal contract opportunity
- Solicitation number
- FA860424RB010
About this file
This document appears to be a set of Question and Answer responses related to a federal contract opportunity with Solicitation Number FA8604-24-R-B010 for a Storage Aids System at Niagara Falls ARS in New York.
The key details are:
- The existing mobile storage system rails are embedded in concrete and not compatible with the new system specified in the solicitation. The document outlines the required steps for installing new compatible rails.
- The solicitation drawing shows rails below each upright, which meets the requirement of rails no more than 7 feet apart. This configuration is confirmed as acceptable.
- The mobile aisle racks on carriages can be anchored to the slab per the requirements.
- Dumpsters can be placed adjacent to the building for removal and disposal of existing equipment.
The related federal contract opportunity is a Request for Proposal (RFP) for a Storage Aids System at Niagara Falls ARS. It is 100% set-aside for small businesses under NAICS code 333922. Proposals are due by July 8, 2024, and the government will award on a Lowest Price Technically Acceptable basis. The performance period is 300 days from date of award.
View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FA860424RB010
Niagara Falls ARS, New York Question Set 9 27 Jun 2024
Question/Answer Response:
1. The rails for the existing GFE mobile storage system(System 2) are imbedded in the concrete and anchored to footers that are 6” below the slab. Further the rails have a “buildup” that extends approximately 12” either side of each rail creating a “bump” as the GFE fork trucks move across each rail. Existing GFE rails were designed for use with the current electric mobile aisle system that is to be removed per the Cover Purchase Description and are not compatible with the system as specified in Appendix B due to the size of the wheels and corresponding rails. In order to meet the requirements of Appendix B, 3.27 the following work needs to be completed.
The area between the existing rails should be backfilled with concrete to a height of 2.5” to 3” LOWER than the height of the top of the existing rails.
Once that hardens, new rails would be installed as required by the size of system. These rails would be leveled to match the height of the top of the existing GFE rails.
When the rail is installed and levelness confirmed, a second pour of concrete would be required to make the top of the rail flush with the now finished floor.
The above represents standard commercial practice for this type of project. Please confirm this is acceptable.
The process as described above would be acceptable for installation of new rails for the mobile storage system.
2. 3.2.7 requires rails be no more than seven feet apart AND rails below each upright. Drawing VNF904- 01 shows rails below each upright. To meet the 7’ requirement another four rails would need to be added to the system which is unnecessary given the capacity requirements for Pallet Rack D and F and the requirements for 3.2.2 Carriages which calls for weight to be 1,000 lbs. per carriage foot. Standard commercial practice for this weight requirement is for rails to be placed below each upright. Please confirm that the configuration as illustrated in VNF904-01 is acceptable.
Yes, the configuration as illustrated in VNF904-01 is acceptable.
3. Drawing VNF904-02, Type A and Type B Mobile Aisle Rack shows the rack on a carriage. Standard commercial practice is for these racks be anchored to the slab as specified in Appendix A, 3.2.5 for Types G and J. Please confirm this is acceptable.
Yes, Type A and Type B mobile aisle rack may be anchored to the slab.
4. Please confirm that a dumpster can be placed adjacent to the building for removal and disposal of the existing equipment as required in Appendix G, 3.1.1.1
Yes, dumpsters can be placed adjacent to the building for removal and disposal of existing equipment.