RFI 2 Response.pdf

PDF 5 KB Posted

Attached to
Replace Fire Alarm System Federal contract opportunity
Solicitation number
FA8601-12-B-0011
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

About this file

RFI 2 Response

View the file

Other files for this federal contract opportunity

Other files attached to Replace Fire Alarm System, newest first.
File Type Posted
FA8601-12-B-0011 - Amendment 5.pdf PDF
General Decision Number - OH29 - 3 AUG 12.pdf PDF
FA8601-12-B-0011 - Amendment 4.pdf PDF
General Decision Number - OH29 - 27 JUL 12.pdf PDF
RFI 4 Response.pdf PDF
RFI 3 Response.pdf PDF
RFI 1 Response.pdf PDF
RFI 5 Response.pdf PDF
RFI 6 Response.pdf PDF
Addendum 2 Drawing A-001.pdf PDF
Addendum 2 Drawing E-221A.pdf PDF
FA8601-12-B-0011 - Amendment 3.pdf PDF
Addendum 2 Drawing T-000.pdf PDF
Site Visit Sign-in Sheet.pdf PDF
Addendum 2 Drawing E-222A.pdf PDF
Addendum 2 Drawing E-223A.pdf PDF
Addendum 2.pdf PDF
Addendum 2 Drawing A-102.pdf PDF
FA8601-12-B-0011 - Addendum 1 Specification.pdf PDF
FA8601-12-B-0011 - Amendment 2.pdf PDF
FA8601-12-B-0011 - Addendum 1.pdf PDF
FA8601-12-B-0011 - Amendment 1 Site Visit Date.pdf PDF
DBA Wage Decision - Bldg Mod 23 6 Jul 12.pdf PDF
Final_FA_20676_Drawings 1 .pdf PDF
FA8601-12-B-0011 Replace Fire Alarm Sys.pdf PDF
Final_FA_20676_Specifications.pdf PDF
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFI 2

Section 28 05 27, Part 2.1 of the specification package reads:

"The system shall communicate digitally to the main fire alarm system panel. All digital parameters of the VESDA panel such as % obscuration, % filter dirty, etc, shall be communicated digitally to the panel. Systems that integrate to the main fire alarm system via a series of addressable dry contact modules to communicate alarm, trouble, supervisory, and other condition are not acceptable. The connection between the VESDA panel and the fire alarm panel must be a digital connection via a digital signaling line circuit."

It is our understanding that there is only one manufacturer that makes this type of system. The others communicate via the dry contact modules that this paragraph specifically excludes. Is this an attempt to sole source this system? If not, could you please provide a list of manufacturers that are capable of communicating as specified?

RESPONSE

See Addendum 1 for response to RFI #2.