PD10WRGBGBEC13
CAGE 98752
Rev C
15 February 2012
Superseding
Rev B, 26 Jan 2012
Rev A, 27 Jan 2011
PD10WRGBGBEC13 - PURCHASE DESCRIPTION (PD)
TRAILER MOUNTED MULTI-AIRCRAFT SERVICING PLATFORM
Fuels Operational Readiness Capability Equipment (FORCE)
2.2.1 Specifications, standards, and handbooks.
Was: MIL-DTL-83133F Turbine Fuels, Aviation, Kerosene Types, NATO F-34 (JP-
8), NATO F-35, and JP-8+100 Change to:
MIL-DTL-83133H
Turbine Fuels, Aviation, Kerosene Types, NATO F-34 (JP-
8), NATO F-35, and JP-8+100
3.8.1.4 Hoses and fittings.
Was: “…Each servicing platform shall also be equipped with two 140-foot, MIL-H-6615, Type I, 3- inch collapsible hoses to be used for cold refueling wide body aircraft”
Change to: “…Each servicing platform shall also be equipped with two 120-foot, MIL-H-6615, Type I, 3- inch collapsible hoses to be used for cold refueling wide body aircraft.”
3.8.1.10 Meters.
Remove: “…The Syn-Tech Fuel Master 2525 Automated Data Collection/Fuel Dispensing System (ADC/FDS) P/N 002A0100 or equivalent is required.”
3.8.1.15.1 Contamination analyzer.
Delete: 3.8.1.15.1 Contamination analyzer. The 6 inch pressure control valve closest to the micronic filter element shall include or work in conjunction with a contamination analyzer, such as the Velcon Filters LLC (CAGE 13573), part number VCA-CV06 or equivalent. The contamination analyzer will continuously monitor the fuel flow stream and will shutdown the flow anytime water levels exceed 10 parts per million or if solids are detected at any level above .5 milligrams per liter. The system shall be configured with a manual override capability to bypass the system if required.