Attachment_13._Safety_Gram.pdf

PDF 216 KB Posted

Attached to
Roofing IDIQ
Solicitation number
FA8501-17-R-0007
Issued by

About this file

Attachment 13. Safety Gram

View the file

Other files

File Type Posted
Attachment_15._Matrix.docx DOCX document
FA8501-17-R-0007_(Amendment_0002).pdf PDF
Attachment_06._AF_Form_3052.xls XLS spreadsheet
Requests_for_Information_(RFIs)_15_May_2017.pdf PDF
Bldg_49_Pic_22.jpg JPG image
Bldg_49_Pic_5.jpg JPG image
Bldg_49_Pic_29.jpg JPG image
Bldg_49_Pic_17.jpg JPG image
Bldg_49_Pic_21.jpg JPG image
Bldg_49_Pic_31.jpg JPG image
Bldg_49_Pic_30.jpg JPG image
Bldg_49_Pic_4.jpg JPG image
Bldg_49_Pic_19.jpg JPG image
Bldg_49_Pic_18.jpg JPG image
Bldg_49_Pic_3.jpg JPG image
Bldg_49_Pic_32.jpg JPG image
Bldg_49_Pic_10.jpg JPG image
Bldg_49_Pic_25.jpg JPG image
Bldg_49_Pic_1.jpg JPG image
Bldg_49_Pic_13.jpg JPG image
Bldg_49_Pic_7.jpg JPG image
Roofing_IDIQ_Pre-Proposal_Conference.pptx PPTX presentation
Bldg_49_Pic_23.jpg JPG image
Bldg_49_Pic_28.jpg JPG image
Bldg_49_Pic_6.jpg JPG image
Bldg_49_Pic_11.jpg JPG image
Bldg_49_Pic_2.jpg JPG image
Bldg_49_Pic_24.jpg JPG image
Bldg_49_Pic_15.jpg JPG image
Bldg_49_Pic_12.jpg JPG image
Bldg_49_Pic_27.jpg JPG image
Bldg_49_Pic_14.jpg JPG image
Roofing_IDIQ_(Bldg_49)_Site_Visit_Sign-In.pdf PDF
Bldg_49_Pic_9.jpg JPG image
Bldg_49_Pic_8.jpg JPG image
Bldg_49_Pic_26.jpg JPG image
Bldg_49_Pic_16.jpg JPG image
Bldg_49_Pic_20.jpg JPG image
FA8501-17-R-0007_(Amendment_0001).pdf PDF
FA8501-17-R-0007_(Roofing_IDIQ_SOLICITATION).pdf PDF
Attachment_02._Appendix_C.pdf PDF
Attachment_07._AF_Form_3064.xls XLS spreadsheet
Attachment_14._Drawings_-_Bldg_49.pdf PDF
Attachment_06._AF_Form_3052.xls XLS spreadsheet
Attachment_12._AF_Form_2586.pdf PDF
Attachment_03._SOW_-_Bldg_49_.pdf PDF
Attachment_09._Schedule_of_Values_example.pdf PDF
Attachment_04._AF66_-_Bldg_49.pdf PDF
Attachment_15._Matrix.docx DOCX document
Attachment_05._AF_Form_3000.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WR-ALC

SAFE-T-GRAM

WR-ALC SAFE-T-GRAM

11-003

SUBJECT: Update 2 Guidance for Cleaning Work Areas

ISSUE DATE: 3 January 14

In accordance with OSHA 29 CFR 1910.1025 (h)(2)(ii), 1910.1026(j)(2)(ii), and

1910.1027 (k)(5), industrial areas of any shop in buildings 44, 45, 46, 47, 48, 49 , 50, 54, 59, 81, 82, 83, 89, 91, 110, 125, 137, 140, 142, 149, 150, 158, 165, 169, 180, 189, 255, 321, 323, 350, 635, 640, 645, 670, 2316, 20031, 20036, and 20180 that have processes that are potential sources of Lead, Chromium VI, and/or Cadmium dust, or that handles parts/equipment previously exposed to this dust, are designated No Dry Sweeping areas.

In addition, adjacent areas such as break rooms, shop floor offices, PSC’s, WSSCs, restrooms, and locker rooms that may potentially be contaminated from dust that has migrated from the industrial area are also designated No Dry Sweeping areas. Any abrasive operation (sanding, grinding, buffing, cutting, trimming, grit blasting, filing, hand sanding, etc.) that may generate Lead, Chromium VI, or Cadmium dust are also designated No Dry Sweeping areas.

Compressed air and dry sweeping may be used in building 59D, the grit blast booth in building 169, building 137 bay 3 & 4, and the two grit blast booths in building 142 as long as the ventilation system is in operation and the proper PPE is used while cleaning.

Dust free cleaning methods: For gross contamination use a HEPA-filtered vacuum.

Other dust free methods include wet methods such as wet wipes, mops, and electrostatic

“swiffer-type” sweepers and are approved for cleaning contaminated surfaces.

Commercial floor scrubbers that use wet methods and do not visibly cause dust to become airborne are also approved for large floor areas.

These procedures are not applicable in administrative areas that are located outside of the production floor areas.

The WR-ALC Safety Office will conduct random visits to these areas to ensure compliance with this guidance and to assist with any questions or concerns expressed.

Additional facilities may be identified through future swipe sampling and inspections.

For additional information, contact your Wing Safety Office @ 468-1708.

Direct waste disposal questions to your group UEC.