This is a detailed technical drawing (module identifiers diagram) for C-130 Maintenance Stands - Generation II, specifically documenting the structural configurations for North West Dock (C1/E3) and South East Dock (C7/E1). The schematic provides comprehensive details about modular aircraft maintenance stand components, including wing stands, tail stands, and bridge sections, with precise measurements, weight specifications, and critical installation notes.
The diagram breaks down the maintenance stand into multiple interconnected modules, highlighting key features such as 10 primary wing stand modules (L1-L4 & R1-R6), 15 tail stand modules (T1-T15), and 10 bridge sections. Each module has specific weight, height, and attachment characteristics, with warnings about proper installation, disconnection procedures, and transportation considerations. Notable design elements include removable legs, cantilevered anchoring, helical pier attachments, and modular units that can be moved independently while maintaining utility connections. The technical drawing provides engineers and maintenance personnel with comprehensive spatial and structural information for the C-130 aircraft maintenance stand system.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 22 - Additional Solicitation Questions.docx | DOCX document | |
| 21 - C-130 Picture 15.jpg | JPG image | |
| 20 - C-130 Picture 14.jpg | JPG image | |
| 14 - C-130 Picture 2.jpg | JPG image | |
| 19 - C-130 Picture 13.jpg | JPG image | |
| 17 - C-130 Picture 11.jpg | JPG image | |
| 15 - C-130 Picture 3.jpg | JPG image | |
| 16 - C-130 Picture 5.jpg | JPG image | |
| 18 - C-130 Picture 12.jpg | JPG image | |
| 11 - C-130-MSG2-193 Module Identifiers-C2 C8.pdf | ||
| 13 - DLA C-130 Shipping.xlsx | XLSX spreadsheet | |
| 10 - Stand ID.png | PNG image | |
| 9 - Solicitation Questions.docx | DOCX document | |
| 3 - 11222 Performance Work Statement (PWS).docx | DOCX document | |
| 2 - Attachment 2_11222 52.212-2 Evaluation Factors.docx | DOCX document | |
| 1 - Attachment 1_11222 52.212-1 Instruction to Offerors.docx | DOCX document | |
| 5 - CDRL A002 Status Report.pdf | ||
| 4 - CDRL A001 Delivery Schedule.pdf | ||
| 8 - CDRL A005 Mishap Report.pdf | ||
| 6 - CDRL A003 Quality Plan.pdf | ||
| 7 - CDRL A004 Safety Plan.pdf | ||
| 0 - 11222 Combo - C130 MX Stands.docx | DOCX document |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L1
L2
L3
L4
L5
L6
R7R8
LV
R2
R4
R5
L7 L8
RV
T1
T2
T3
T4
T5
T6
T8
T7
T21
T12
T10 T11
T13 T14T15
T18T17T16 T19
T9
C1
C3
C5
C7
C9
C2
C4
C6
C8
C10
C11
C12
C13
14A
C15 C18
C16 C17
C26
C25
C24
C23 C22-L
C22-R
C19
C20
C21
MODULE IDENTIFIERS
C1/E3 (NORTH WEST DOCK)
C7/E1 (SOUTH EAST DOCK)
L9R9
LEFT WING
STAND STAIRS
RIGHT WING
STAND STAIRS
TAIL STAND STAIRS
COLUMNS ARE
PERMANENTLY ATTACHED
TO WING STAND MODULES
(TYPICAL OF 4 PER MODULE)
AIRCRAFT NORTH
THE 10 BRIDGE SECTIONS
(L7-L9, R7-R9 & T16-T19)
ARE SUPPORTED BY
ADJACENT WING AND/OR
TAIL STAND MODULES.
THE PORTION OF STANDS UNDERNEATH THE
TAIL OF THE C-130 IS KNOW AS THE "TAIL
STAND" AND IS COMPRISED OF 15 MODULES
(T1-T15) SUPPORTED BY SHARED REMOVABLE
LEGS. ONCE SEPARATED, EACH MODULE CAN
BE MOVED AS A UNIT WITH UTILITIES INTACT.
MODULE T21 IS DESIGNED TO BE EASILY
REMOVED TO ACCOMMODATE LONGER
C-130 AIRCRAFT. CASTERS, STORED
INSIDE THE DECK SECTION ARE DESIGNED
TO BE INSTALLED ON BRACKETS UNDER
THE DECK SECTION. A KIT IS AVAILABLE
WHICH INCLUDES LIFTING RINGS, SLINGS,
ETC. FOR CRANE ASSISTED REMOVAL.
27 COLUMNS SUPPORTING THE TAIL STAND
ARE REMOVABLE WITH UTILITIES STILL
CONNECTED TO EACH COLUMN. EACH
COLUMN WEIGHS APPROX. 325 LBS.
WARNING: IN ORDER TO PREVENT THE
SYSTEMS FROM TIPPING OVER, THE
TWO FUELS VENTILATION SYSTEMS
(LABELED LV AND RV) HAVE YELLOW OR
BLUE MASTS AND BOOM ARMS (WHICH
SUPPORT THE SUSPENDED DUCTS)
WHICH MUST BE REMOVED PRIOR TO
DISCONNECTING THE SYSTEM FROM
THE HELICAL PIERS IN THE FLOOR.
THE PORTION OF STANDS UNDERNEATH THE MAIN WING OF THE C-130 ARE
KNOW AS "WING STANDS" AND ARE COMPRISED OF 10 PRIMARY MODULES
(L1-L4 & R1-R6). THESE 10 WING STAND MODULES ARE ALL INDEPENDENTLY
SELF SUPPORTIVE WITH 4 NON-REMOVABLE LEGS ATTACHED TO EACH MODULE.
ONCE SEPARATED FROM THE REST OF THE STAND, EACH MODULE CAN BE
MOVED AS A COMPLETE INDEPENDENT UNIT WITH ALL UTILITIES INTACT.
WARNING! THIS MODULE IS A
CANTILEVERED MODULE ANCHORED TO
THE FLOOR WITH 3 HELICAL PIERS TO
KEEP IT FROM TIPPING OVER. TWO
YELLOW RETRACTABLE LEGS MUST BE
LOWERED PRIOR TO DISCONNECTING
FROM THE HELICAL PIERS. FOR
TRANSPORT, THE FIXED LEGS MAY BE
REMOVED AND THE DECK RIGGED AT AN
ANGLE TO REDUCE THE SHIPPING WIDTH.
24'-9"7'-1"13'-11"6'-4"12'-3"20'
12'-3"6'-4"13'-11"7'-1"17'-6"
20'-1"
17'
17'-6"
6'-4"8'-10"8'-10"
6'-4"
24'
6'
5'-1"
12'-11"
13'-6"
BRIDGE R9/L9
STAYS
CONNECTED
TO R1/L1.
10'-5" tall
13,000 LBS
10'-3" tall
11,000 LBS
9'-7" tall
10,100 LBS
9'-1" tall
9,700 lbs
9'-7" tall
10,800 LBS
9'-1" tall
7,900 lbs
TOP OF STRUCTURE = 10'-8"
TOP OF HVAC = 13'-8"
TOP OF DUCT = 18'
9'-1" tall
9,700 lbs
9'-1" tall
7,900 lbs
9'-7" tall
10,100 LBS
9'-7" tall
10,800 LBS
24,000 LBS
LBS
LBS
LBS
LBS
LBS
LBS
LBS
LBS
LBS
LBS
LBS3640
LBS
LBS
LBS
LBS
LBS
10,000
LBS
10,000
LBS
LBS
LBS
LBS
LBS
NOTES:
1. WEIGHTS INDICATED ARE FOR THE MAIN STRUCTURE. ADD
ABOUT 10% TO COVER UTILITIES, HANDRAIL, MISC.
2. HEIGHTS INDICATED ARE TO THE TOP OF DECK STRUCTURE
(DOES NOT INCLUDE HANDRAILS)
3. LEGS ARE REMOVABLE FROM THE STAND SECTIONS BUT NOT
THE WING STAND SECTIONS.
4. WHEN SHIPPING, DUNNAGE WILL BE REQUIRED TO SUPPORT
THE WEIGHT OF EACH TAIL STAND DECK SECTION TO PREVENT
CRUSHING THE UTILITIES HANGING UNDERNEATH.
R1R3
A A
3 2 1
3 2 1
B B
C C
D D
309 AMXG/EN - HILL AFB, UT
CHECKED/DATE
ENGINEER/DATE
DRAWN BY/DATE
LAYOUT BY/DATE
APPROVED/DATE
DO NOT SCALE DRAWING
ALL DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE NOTED.
TOLERANCES UNLESS NOTED
XX±.01
XXX±.001
ANG±.05°
SAFETY/DATE
FSCM NO.SIZE
DWG NAME
REV
SHEET
DWG NO.
SCALE
Burk Stevens / 2017.10.17
C
C-130-MSG2-192
1/8" = 1'-0"
C-130 MAINTENANCE STANDS - GEN II
MODULE IDENTIFIERS DOCKS C1/C7