Tab 1. ACS EY101_501.pdf
PDF 321 KB Posted
- Attached to
- Access Control System Equipment Federal contract opportunity
- Solicitation number
- FA813925Q0002
About this file
This is an electrical security plan showing floor plans and detailed diagrams for an Access Control System (ACS) installation at Tinker AFB, OK. The drawings include both an overall electrical security plan and detailed rough-in diagrams for single and double door installations.
The floor plan shows multiple administrative areas (Admin 1-6) with varying numbers of workstations, totaling approximately 87 workstations across all areas. The security infrastructure includes door contacts, card readers, electric strikes, and request-to-exit (REX) sensors. The detailed diagrams specify 3/4" conduit requirements, junction box placements, and wiring paths for both access control and intrusion detection systems. The plans indicate integration requirements with fire alarm systems for door release and specify that rough-in work must comply with DoD 5200.01 Vol 3 standards for secure open storage spaces. The contractor is responsible for providing junction boxes and conduit while the owner will install wiring and components.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions and Answers_23 Dec 2024.pdf | ||
| Tab 3. ACS ET401.pdf | ||
| Tab 2. ACS A601.pdf | ||
| Tab 4. Door Hardware_Lines 284, 286-290.pdf | ||
| Questions and Answers.pdf | ||
| Brand Name Justification_Redacted.pdf | ||
| 12467 CDRL A002 Training Certificate.pdf | ||
| FA813925Q0002.pdf | ||
| 12467 CDRL A004 72hr Failure Plan.pdf | ||
| Performance Work Statement w. App C.pdf | ||
| 12467 CDRL A001 Design Drawings.pdf | ||
| 12467 CDRL A003 Installation Items.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
ADMIN 3A
Workstations 8 177A
ADMIN 2
Workstations 30
FACILITY
Workstations 4
Office 1
Workstations 1
Office 2
181A
181B
ADMIN 5
Workstations 16
ADMIN 1
Workstations 3
MECHANICAL ROOM
Security Office
Workstations 1
VAULTSTORAGE
STORAGE
185A185B
LAB
MECHANICAL & ELECTRICAL ROOM
178A
178B
ADMIN 4
Workstations 16
76 SWEG
COMM. RM
BREAK AREA
ADMIN 3
Workstations 15
ELEC. RM
MEN
175A
175B
WOMEN
72 ABW
COMM. RM
176A
JAN.
Workstations 1
ADMIN 6
Workstations 13
V
V
HGFEDB1A CB J
EL
EC
TR
IC
AL
SE
C U
R
IT
Y
PL
AN
- N
EW
W
O R
K
EY101
KL
JS
JM
OF
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
W W
YK
R
EN
O
VA
TE
N
W A
R
EA
O F
IN
TE
G R
AT
IO
N S
U
PP
O R
T, B
M
AY
H D
R
KEYPLAN
ELECTRICAL SECURITY PLAN - NEW WORK
SCALE: 3/32" = 1'-0"
EY101
GENERAL NOTES:
1. INSTALLATION TO BE IN ACCORDANCE WITH DoD 5200.01 VOLUME 3
AS IT APPLIES TO SECURE OPEN STORAGE.
2. COORDINATE ROUTING OF CONDUITS WITH EXISTING CONDITIONS,
BASE COMM SQUADRON, AND BASE SECURITY.
3. ACCESS CONTROL SYSTEM (ACS) COMPONENTS AND HARDWARE
WILL BE OWNER FURNISHED OWNER INSTALLED. CONTRACTOR
RESPONSIBLE TO PROVIDE ALL ROUGH-INS AND RACEWAYS TO
SUPPORT THE COMPLETE INSTALLATION. CONFIRM REQUIREMENTS
WITH BASE SECURITY AND USER PRIOR TO ROUGH-IN.
4. INTRUSION DETECTION SYSTEM (IDS) COMPONENTS AND
HARDWARE WILL BE OWNER FURNISHED OWNER INSTALLED.
CONTRACTOR RESPONSIBLE TO PROVIDE ALL WALL AND DOOR
ROUGH-INS AND RACEWAYS, OWNER WILL BE RESPONSIBLE FOR
MOTION DETECTOR ROUGH-IN, TO SUPPORT THE COMPLETE
INSTALLATION. CONFIRM REQUIREMENTS WITH BASE SECURITY AND
USER PRIOR TO ROUGH-IN.
5. ALL RECESSED ROUGH-INS WILL BE PROVIDED WITH ACOUSTICAL
PADS, STI SSP OR EQUAL. ROUGH-INS ON OPPOSITE SIDES OF
WALL REQUIRE MINIMUM 16" HORIZONTAL SEPARATION.
6. COORDINATE ROUGH-INS WITH DOOR HARDWARE SUPPLIER AND
BASE SECURITY OFFICER. PROVIDE ROUGH-IN AS REQUIRED FOR
DOOR CONTACTS, ELECTRIC STRIKES, CARD READERS, AND
REQUEST-TO-EXIT DEVICES.
SECURE DOOR WITH ACCESS CONTROLS. SEE DETAIL 1/EY501.
SECURE DOOR WITH INTRUSION DETECTION. SEE DETAIL 2/EY501.
SECURE DOOR WITH ACCESS CONTROLS AND INTRUSION DETECTION.
SEE DETAIL 4/EY501.
MOTION DETECTOR. ROUGH-IN AND DEVICES WILL BE OWNER
FURNISHED OWNER INSTALLED. LOCATIONS NOT SHOWN.
VINDICATOR SECURE/ACCESS SITE COMMANDER - 42" AFF. PROVIDE
3/4" CONDUIT HOMERUNNED TO THE ACS OR IDS SYSTEM PANEL AS
INDICATED.
CARD READER - 42" AFF
DURESS BUTTON - 42" AFF
TAMPER SWITCH
DOOR CONTACT
ELECTRIFIED LOCKSET
REQUEST TO EXIT MOTION DEVICE
LEGEND:
M
V
C
T
D
D
E
KEYED NOTES:
PERIMETER BOUNDARY OF SECURE OPEN STORAGE AREA.
CONSTRUCT PER DoD 5200.01 VOL 3. COORDINATE WITH BASE
SECURITY TO ENSURE THAT ALL PERIMETER OPENINGS ARE
SEALED AND ALL PERIMETERS WALLS ARE INSPECTIBLE.
3/4" CONDUIT TO PULLBOX 'ESS' IN COMM ROOM 176 FOR FUTURE
ACCESS CONTROL SYSTEM WIRING.
3/4" CONDUIT TO PULLBOX 'ESS' IN COMM ROOM 176 FOR FUTURE
INTRUSION DETECTION SYSTEM WIRING.
PULLBOX 'ESS'. REFER TO ELECTRONIC SECURITY SYSTEM RISER
6/EY501.
EXISTING DOOR. ROUGH-IN FOR IDS WILL BE SURFACE MOUNT.
ROUGH-IN FOR ELECTRONIC SECURITY SITE COMMANDER.
PROVIDE RECESSED 4-SQUARE BOX AT 48". PROVIDE 1" CONDUIT
TO PULLBOX 'ESS'. CONFIRM LOCATION WITH CONTRACTING
OFFICER PRIOR TO ROUGH-IN.
DOOR WILL BE PROVIDED WITH CDX10 LOCK. REFER TO
ARCHITECTURAL SHEETS AND HARDWARE SCHEDULE.
2 2
REX
05/24/21205/2
EL
EC
TR
IC
AL
SE
C U
R
IT
Y D
ET
AI
LS
EY501
KL
JS
JM
OF
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
W W
YK
R
EN
O
VA
TE
N
W A
R
EA
O F
IN
TE
G R
AT
IO
N S
U
PP
O R
T, B
M
AY
H D
R
DOOR POWER SUPPLY
PROVIDED BY DIV 08
AND INSTALLED BY
DIVISION 26.
3/4" CONDUIT. FOR SURFACE
MOUNT APPLICATIONS PROVIDE
WIREMOLD 700 SERIES SURFACE
MOUNTED WIREMOLD. PROVIDE
BOXES AS REQUIRED FOR
DEVICES. COORDINATE WIRING
FOR ELECTRIC STRIKE AND
DOOR CONTACT WITH DOOR
AND HARDWARE VENDOR.
NOTES THIS DIAGRAM:
1. CONTRACTOR SHALL PROVIDE ALL NECESSARY JUNCTION BOXES AND
CONDUIT TO PROVIDE A COMPLETE AND OPERABLE ACS ROUGH-IN.
OWNER TO INSTALL ALL WIRING AND COMPONENTS. COORDINATE FINAL
ROUGH-IN REQUIREMENTS WITH OWNER AND ESS INSTALLER.
2. PROVIDE JUNCTION BOX ABOVE SECURITY PULL BOX WITH A 120V
CIRCUIT AND A 3/4" NIPPLE BETWEEN THE TWO BOXES.
3. DOOR CONTACT ROUGH-IN SHOWN IS DEDICATED TO ACCESS CONTROL.
4. ROUGH-IN TO BE IN ACCORDANCE WITH DOD 5200.01 VOL 3 FOR
SECURE OPEN STORAGE SPACES.
J
120V
D
3/4" CONDUIT. FOR
SURFACE MOUNT
APPLICATIONS PROVIDE
WIREMOLD 700 SERIES
SURFACE MOUNTED
WIREMOLD. COORDINATE
WIRING FOR DOOR
CONTACT WITH DOOR AND
HARDWARE VENDOR.
NOTES THIS DIAGRAM:
1. CONTRACTOR SHALL PROVIDE ALL NECESSARY JUNCTION BOXES AND
CONDUIT TO PROVIDE A COMPLETE AND OPERABLE IDS ROUGH-IN.
OWNER TO INSTALL ALL WIRING AND COMPONENTS. COORDINATE FINAL
ROUGH-IN REQUIREMENTS WITH OWNER AND ESS INSTALLER.
2. DOOR CONTACT ROUGH-IN SHOWN IS DEDICATED TO INTRUSION
DETECTION.
3. ROUGH-IN TO BE IN ACCORDANCE WITH DOD 5200.01 VOL 3 FOR
SECURE OPEN STORAGE SPACES.
ON EXTERIOR
SIDE OF DOOR
CEILING CEILING
D
T
C
ACCESS CONTROL
SINGLE DOOR ROUGH-IN DETAIL
N.T.S.
EY501
INTRUSION DETECTION
SINGLE DOOR ROUGH-IN DETAIL
N.T.S.
EY501
E
IN DOOR FRAME
8" x 8" x 4" PULL BOX
T
3/4" CONDUIT
3/4" CONDUIT TO PULL
BOX 'ESS'
4" x 4" x 4" PULL BOX
T
3/4" CONDUIT TO PULL
BOX 'ESS'
3/4" CONDUIT TO
INTEGRATE WITH FIRE
ALARM SYSTEM FOR
LOCK RELEASE WIRING.
PULL BOX 'ESS' IN COMM ROOM 176
72" x 8" x 6"
MOUNT 10' AFF
ELECTRONIC
SECURITY SYSTEM RISER
SCALE: NTS
EY501
IDS CONTROLLER AND IDS
WIRING TO BE INSTALLED IN A
SEPARATE CONTRACT.
3/4"CONDUITS, QUANTITY AS
REQUIRED, FOR ACS AND IDS
ROUGH-INS. REFER TO FLOOR
PLAN FOR LOCATIONS. PROVIDE
PULL STRINGS IN ALL CONDUITS.
ACS CONTROLLER AND ACS
WIRING TO BE INSTALLED IN A
SEPARATE CONTRACT.
REX
3/4" CONDUIT. FOR SURFACE
MOUNT APPLICATIONS PROVIDE
WIREMOLD 700 SERIES SURFACE
MOUNTED WIREMOLD. PROVIDE
BOXES AS REQUIRED FOR
DEVICES. COORDINATE WIRING
FOR ELECTRIC STRIKE AND
DOOR CONTACT WITH DOOR
AND HARDWARE VENDOR.
NOTES THIS DIAGRAM:
1. CONTRACTOR SHALL PROVIDE ALL NECESSARY JUNCTION BOXES AND
CONDUIT TO PROVIDE A COMPLETE AND OPERABLE ACS ROUGH-IN.
OWNER TO INSTALL ALL WIRING AND COMPONENTS. COORDINATE FINAL
ROUGH-IN REQUIREMENTS WITH OWNER AND ESS INSTALLER.
2. PROVIDE JUNCTION BOX ABOVE SECURITY PULL BOX WITH A 120V
CIRCUIT AND A 3/4" NIPPLE BETWEEN THE TWO BOXES.
3. DOOR CONTACT WILL HAVE TWO INDEPENDENT OUTPUTS.
4. ROUGH-IN TO BE IN ACCORDANCE WITH DOD 5200.01 VOL 3 FOR
SECURE OPEN STORAGE SPACES.
J 120V
ON EXTERIOR
SIDE OF DOOR
CEILING
D
T
C
ACCESS CONTROL AND INTRUSION
DETECTION SINGLE DOOR ROUGH-IN DETAIL
N.T.S.
EY501
E
IN DOOR FRAME
8" x 8" x 4" PULL BOX
T
3/4" CONDUIT
3/4" CONDUIT TO PULL BOX 'ESS'
3/4" CONDUIT TO INTEGRATE WITH FIRE
ALARM SYSTEM FOR LOCK RELEASE WIRING.
REX
T
3/4" CONDUIT TO PULL
BOX 'ESS'
4" x 4" x 4" PULL BOX
DOOR POWER SUPPLY
PROVIDED BY DIV 08
AND INSTALLED BY
DIVISION 26.
AS
R
EQ
U
IR
ED
6" 48
AS
R
EQ
U
IR
ED
6" 48
D
3/4" CONDUIT. FOR SURFACE MOUNT
APPLICATIONS PROVIDE WIREMOLD
700 SERIES SURFACE MOUNTED
WIREMOLD. COORDINATE WIRING
FOR DOOR CONTACT WITH DOOR
AND HARDWARE VENDOR.
NOTES THIS DIAGRAM:
1. CONTRACTOR SHALL PROVIDE ALL NECESSARY JUNCTION BOXES AND
CONDUIT TO PROVIDE A COMPLETE AND OPERABLE IDS ROUGH-IN.
OWNER TO INSTALL ALL WIRING AND COMPONENTS. COORDINATE FINAL
ROUGH-IN REQUIREMENTS WITH OWNER AND ESS INSTALLER.
2. DOOR CONTACT ROUGH-IN SHOWN IS DEDICATED TO INTRUSION
DETECTION.
3. ROUGH-IN TO BE IN ACCORDANCE WITH DOD 5200.01 VOL 3 FOR
SECURE OPEN STORAGE SPACES.
CEILING
INTRUSION DETECTION
DOUBLE DOOR ROUGH-IN DETAIL
N.T.S.
EY501
4" x 4" x 4" PULL BOX
T
3/4" CONDUIT TO PULL
BOX 'ESS'
D
3/4" CONDUIT. FOR SURFACE
MOUNT APPLICATIONS PROVIDE
WIREMOLD 700 SERIES SURFACE
MOUNTED WIREMOLD. PROVIDE
BOXES AS REQUIRED FOR
DEVICES. COORDINATE WIRING
FOR ELECTRIC STRIKE AND
DOOR CONTACT WITH DOOR
AND HARDWARE VENDOR.
NOTES THIS DIAGRAM:
1. CONTRACTOR SHALL PROVIDE ALL NECESSARY JUNCTION BOXES AND
CONDUIT TO PROVIDE A COMPLETE AND OPERABLE ACS ROUGH-IN.
OWNER TO INSTALL ALL WIRING AND COMPONENTS. COORDINATE FINAL
ROUGH-IN REQUIREMENTS WITH OWNER AND ESS INSTALLER.
2. PROVIDE JUNCTION BOX ABOVE SECURITY PULL BOX WITH A 120V
CIRCUIT AND A 3/4" NIPPLE BETWEEN THE TWO BOXES.
3. DOOR CONTACT WILL HAVE TWO INDEPENDENT OUTPUTS.
4. ROUGH-IN TO BE IN ACCORDANCE WITH DOD 5200.01 VOL 3 FOR
SECURE OPEN STORAGE SPACES.
J 120V
ON EXTERIOR
SIDE OF DOOR
CEILING
D
T
C
ACCESS CONTROL AND INTRUSION
DETECTION DOUBLE DOOR ROUGH-IN DETAIL
N.T.S.
EY501
E
IN DOOR FRAME
8" x 8" x 4" PULL BOX
T
3/4" CONDUIT
3/4" CONDUIT TO PULL BOX 'ESS'
3/4" CONDUIT TO INTEGRATE WITH FIRE
ALARM SYSTEM FOR LOCK RELEASE WIRING.
REX
T
3/4" CONDUIT TO PULL
BOX 'ESS'
4" x 4" x 4" PULL BOX
DOOR POWER SUPPLY
PROVIDED BY DIV 08
AND INSTALLED BY
DIVISION 26.
AS
R
EQ
U
IR
ED
6" 48
05/24/21205/2
File details come from the government source that posted it. Updated .