This is a technical specification document for exterior lighting systems at Tinker Air Force Base, Oklahoma, issued in April 2019 under Section 26 56 00.

The specification establishes comprehensive requirements for HID and LED luminaires, poles, brackets, controls, and related equipment for exterior applications. LED luminaires must achieve minimum efficacy ratings of 65 lumens per watt for pole/arm-mounted area and roadway luminaires, 65 lumens per watt for decorative luminaires, 60 lumens per watt for wall-mounted area luminaires, 35 lumens per watt for bollards, and 70 lumens per watt for parking garage luminaires, all tested per IES LM-79. LED light sources must have a correlated color temperature of 4000K (3985±275K) with a minimum color rendering index of 70, and manufacturers must utilize maximum 4-step MacAdam ellipse binning for color consistency. LED luminaires require a minimum 10-year on-site replacement warranty for materials, fixture finish, and workmanship, with useful life certification correlating to IES LM-80 test data using IES TM-21 procedures. Poles must be designed for 100 mph wind loading per AASHTO LTS and may be constructed of concrete (ASTM C1089 with 7000 psi 28-day compressive strength), aluminum (6063-T6 or 6005-T5 alloys), steel (minimum 11-gauge galvanized), or treated wood (Southern Yellow Pine or Douglas Fir per AWPA U1). All luminaires must be UL 1598 listed for wet locations with minimum IP65 rating for LED optical compartments, include baked-on enamel or powder coat finishes capable of surviving 2500 hours ASTM B117 salt fog testing, and incorporate surge protection to meet IEEE C62.41.2 C Low waveforms. Control equipment includes photocells (UL 773/773A), timeswitches with 56 on/off setpoints, lighting contactors, relay panels compatible with BACnet or LONworks controls, and dual-technology motion sensors per NEMA WD 7. Electronic ballasts for HID luminaires must exceed 90 percent power factor and operate at -22°F minimum temperature, while LED drivers must achieve minimum 85 percent efficiency with power factor ≥0.90 and <20 percent total harmonic distortion. Submittals require photometric plans showing horizontal and vertical illuminance at specified intervals, design data including IES distribution classifications and B.U.G. ratings, and operating test results after 100 hours of burn-in. Installation follows IEEE C2 and NFPA 70 standards, with wood poles set at depths ranging from 5 to 8 feet depending on length and concrete/steel/aluminum poles installed per manufacturer instructions.

View the file

Other files

File Type Posted
03 39 00.00 10.pdf PDF
03 62 16.pdf PDF
04 20 00.pdf PDF
05 21 00.pdf PDF
06 20 00.pdf PDF
06 61 16.pdf PDF
07 60 00.pdf PDF
07 61 14.00 20.pdf PDF
07 84 00.pdf PDF
07 92 00.pdf PDF
08 11 16.pdf PDF
08 36 13.pdf PDF
08 71 00.pdf PDF
09 68 00.pdf PDF
10 28 13.pdf PDF
13 48 00.pdf PDF
21 13 17.pdf PDF
22 00 00.pdf PDF
23 00 00.pdf PDF
23 08 00.pdf PDF
23 11 25.pdf PDF
23 35 00.pdf PDF
23 64 26.pdf PDF
23 82 16.00 40.pdf PDF
23 82 43.00 40.pdf PDF
31 23 06.pdf PDF
32 01 14.pdf PDF
32 13 74.pdf PDF
03 11 13.00 10.pdf PDF
03 20 00.00 10.pdf PDF
03 30 00.pdf PDF
07 14 00.pdf PDF
07 19 00.pdf PDF
190023 Renovate Restrooms B117 RFIs_FINAL_COR_Signed.pdf PDF
TAFB_Tech_Reqs (Div 02-48).zip ZIP file
Model.zip ZIP file
00 71 00.pdf PDF
01 78 23.pdf PDF
000_TABLE OF CONTENTS.pdf PDF
01 32 16.00 20.pdf PDF
01 33 16.00 10.pdf PDF
01 42 00.pdf PDF
01 78 00.pdf PDF
Tinker General Requirements Specifications_Nov 2022_Change Log.pdf PDF
Initial Site Visit WWYK190023.pdf PDF
Solicitation - FA813726R0030.pdf PDF
Att10_190023_SOW.pdf PDF
EAL List - BLANK to Contractors WWYK190023.xlsx XLSX spreadsheet
Att12_190023_Drawings_Final.pdf PDF
Section L - Instructions to Offerors.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019

SECTI ON 26 56 00

EXTERI OR LI GHTI NG

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by t he basi c desi gnat i on onl y.

ALLI ANCE FOR TELECOMMUNI CATI ONS I NDUSTRY SOLUTI ONS ( ATI S)

ATI S ANSI O5. 1 ( 2008) Wood Pol es - - Speci f i cat i ons & Dimensions

AMERI CAN ASSOCI ATI ON OF STATE HI GHWAY AND TRANSPORTATI ON OFFI CI ALS

(AASHTO)

AASHTO LTS ( 2013; Er r at a 2013) St andar d Speci f i cat i ons f or St r uct ur al Suppor t s f or Hi ghway Si gns, Lumi nai r es and Tr af f i c Signals

AMERI CAN SOCI ETY OF HEATI NG, REFRI GERATI NG AND AI R- CONDI TI ONI NG

ENGI NEERS ( ASHRAE)

ASHRAE 90. 1 - I P ( 2010) Ener gy St andar d f or Bui l di ngs Except Low- Ri se Resi dent i al Bui l di ngs

ASHRAE 90. 1 - SI ( 2010) Ener gy St andar d f or Bui l di ngs Except Low- Ri se Resi dent i al Bui l di ngs

AMERI CAN WOOD PROTECTI ON ASSOCI ATI ON ( AWPA)

AWPA U1 ( 2015) Use Cat egor y Syst em: User Speci f i cat i on f or Tr eat ed Wood

ASTM I NTERNATI ONAL ( ASTM)

ASTM A153/ A153M ( 2016) St andar d Speci f i cat i on f or Zi nc Coat i ng ( Hot - Di p) on I r on and St eel Hardware

ASTM B108/ B108M ( 2015) St andar d Speci f i cat i on f or Al umi num- Al l oy Per manent Mol d Cast i ngs

ASTM B117 ( 2011) St andar d Pr act i ce f or Oper at i ng Sal t Spr ay ( Fog) Appar at us

ASTM C1089 ( 2013) St andar d Speci f i cat i on f or Spun Cast Pr est r essed Concr et e Pol es

I LLUMI NATI NG ENGI NEERI NG SOCI ETY ( I ES)

I ES HB- 10 ( 2011; Er r at a 2015) I ES Li ght i ng Handbook

Apr i l 2019 Page 1 SECTI ON 26 56 00

I ES LM- 79 ( 2008) El ect r i cal and Phot omet r i c Measur ement s of Sol i d- St at e Li ght i ng Products

I ES LM- 80 ( 2015) Measur i ng Lumen Mai nt enance of LED Li ght Sour ces

I ES RP- 16 ( 2010; Addendum A 2008; Addenda B 2009;

Addendum C 2016) Nomencl at ur e and Def i ni t i ons f or I l l umi nat i ng Engi neer i ng

I ES RP- 8 ( 2014) Roadway Li ght i ng

I ES TM- 15 ( 2011) Lumi nai r e Cl assi f i cat i on Syst em f or Out door Lumi nai r es

I ES TM- 21 ( 2011) Pr oj ect i ng Long Ter m Lumen Mai nt enance of LED Li ght Sour ces

I NSTI TUTE OF ELECTRI CAL AND ELECTRONI CS ENGI NEERS ( I EEE)

I EEE 100 ( 2000; Ar chi ved) The Aut hor i t at i ve Di ct i onar y of I EEE St andar ds Ter ms

I EEE C2 ( 2012; Er r at a 1 2012; I NT 1- 4 2012; Er r at a

2 2013; I NT 5- 7 2013; I NT 8- 10 2014; I NT

11 2015; I NT 12 2016) Nat i onal El ect r i cal Saf et y Code

I EEE C62. 41 ( 1991; R 1995) Recommended Pr act i ce on Sur ge Vol t ages i n Low- Vol t age AC Power Circuits

I EEE C62. 41. 2 ( 2002) Recommended Pr act i ce on Char act er i zat i on of Sur ges i n Low- Vol t age ( 1000 V and Less) AC Power Ci r cui t s

NATI ONAL ELECTRI CAL MANUFACTURERS ASSOCI ATI ON ( NEMA)

ANSI C136. 13 ( 2004; R 2009) Amer i can Nat i onal St andar d f or Roadway Li ght i ng Equi pment , Met al Br acket s f or Wood Pol es

ANSI C136. 21 ( 2014) Amer i can Nat i onal St andar d f or Roadway and Ar ea Li ght i ng Equi pment - Ver t i cal Tenons Used wi t h Post - Top- Mount ed Luminaires

ANSI C136. 3 ( 2014) Amer i can Nat i onal St andar d f or Roadway and Ar ea Li ght i ng Equi pment Lumi nai r e At t achment s

ANSI C78. 1381 ( 1998) Amer i can Nat i onal St andar d f or El ect r i c Lamps - 250- Wat t , 70 Wat t , M85 Met al - Hal i de Lamps

ANSI C82. 4 ( 2002) Amer i can Nat i onal St andar d f or Bal l ast s f or Hi gh- I nt ensi t y- Di schar ge and

Apr i l 2019 Page 2 SECTI ON 26 56 00

Low- Pr essur e Sodi um ( LPS) Lamps ( Mul t i pl e- Suppl y Type)

ANSI / ANSLG C78. 43 ( 2013) Amer i can Nat i onal St andar d f or El ect r i c Lamps - Si ngl e- Ended Met al - Hal i de Lamps

NEMA 250 ( 2014) Encl osur es f or El ect r i cal Equi pment ( 1000 Vol t s Maxi mum)

NEMA ANSLG C78. 377 ( 2015) Amer i can Nat i onal St andar d f or El ect r i c Lamps— Speci f i cat i ons f or t he Chr omat i c i t y of Sol i d St at e Li ght i ng Products

NEMA ANSLG C78. 380 ( 2007) El ect r i c Lamps - Hi gh I nt ensi t y Di schar ge Lamps, Met hod of Desi gnat i on

NEMA ANSLG C78. 44 ( 2008) For El ect r i c Lamps - Doubl e- Ended Met al Hal i de Lamps

NEMA ANSLG C82. 14 ( 2006) Lamp Bal l ast s Low- Fr equency Squar e Wave El ect r oni c Bal l ast s - - f or Met al Hal i de Lamps

NEMA C136. 31 ( 2010) Amer i can Nat i onal f or Roadway and Ar ea Li ght i ng Equi pment - Lumi nai r e Vibration

NEMA C78. LL 3 ( 2003; R 2015) El ect r i c Lamps - Pr ocedur es f or Hi gh I nt ensi t y Di schar ge Lamp Sampl e Pr epar at i on and t he Toxi c i t y Char act er i st i c Leachi ng Pr ocedur e

NEMA C82. 77 ( 2002) Har moni c Emi ssi on Li mi t s - Rel at ed Power Qual i t y Requi r ement s f or Li ght i ng Equipment

NEMA I CS 2 ( 2000; R 2005; Er r at a 2008) St andar d f or Cont r ol l er s, Cont act or s, and Over l oad Rel ays Rat ed 600 V

NEMA I CS 6 ( 1993; R 2011) Encl osur es

NEMA I EC 60529 ( 2004) Degr ees of Pr ot ect i on Pr ovi ded by Encl osur es ( I P Code)

NEMA WD 7 ( 2011) Occupancy Mot i on Sensor s St andar d

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 70 ( 2014; AMD 1 2013; Er r at a 1 2013; AMD 2 2013; Er r at a 2 2013; AMD 3 2014; Er r at a 3- 4 2014; AMD 4- 6 2014) Nat i onal El ect r i cal Code

U. S. DEPARTMENT OF AGRI CULTURE ( USDA)

RUS Bul l 1728F- 700 ( 2011) Speci f i cat i on f or Wood Pol es, Apr i l 2019 Page 3 SECTI ON 26 56 00

St ubs, and Anchor Logs

U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)

47 CFR 15 Radi o Fr equency Devi ces

47 CFR 18 ( 2011) I ndust r i al , Sci ent i f i c , and Medi cal Equipment

UNDERWRI TERS LABORATORI ES ( UL)

UL 1029 ( 1994; Repr i nt Dec 2013) Hi gh- I nt ensi t y- Di schar ge Lamp Bal l ast s

UL 1310 ( 2011; Repr i nt Dec 2014) UL St andar d f or Saf et y Cl ass 2 Power Uni t s

UL 1598 ( 2008; Repr i nt Oct 2012) Lumi nai r es

UL 773 ( 1995; Repr i nt Jul 2015) St andar d f or Pl ug- I n, Locki ng Type Phot ocont r ol s f or Use wi t h Ar ea Li ght i ng

UL 773A ( 2016) St andar d f or Noni ndust r i al Phot oel ect r i c Swi t ches f or Li ght i ng Cont r ol

UL 8750 ( 2009; Repr i nt May 2014) UL St andar d f or Saf et y Li ght Emi t t i ng Di ode ( LED) Equi pment f or Use i n Li ght i ng Pr oduct s

1. 2 RELATED REQUI REMENTS

Mat er i al s not consi der ed t o be l umi nai r es or l i ght i ng equi pment ar e speci f i ed i n Sect i on( s) 33 71 02 UNDERGROUND ELECTRI CAL DI STRI BUTI ON.

Lumi nai r es and accessor i es i nst al l ed i n i nt er i or of bui l di ngs ar e speci f i ed i n Sect i on 26 51 00 I NTERI OR LI GHTI NG.

1. 3 DEFINITIONS

a. Unl ess ot her wi se speci f i ed or i ndi cat ed, el ect r i cal and el ect r oni cs t er ms used i n t hese speci f i cat i ons, and on t he dr awi ngs shal l be as def i ned i n I EEE 100 and I ES RP- 16.

b. For HI D and f l uor escent l umi nai r e l i ght sour ces, " Aver age Rat ed Li f e" i s t he t i me af t er whi ch 50 per cent of a l ar ge gr oup of l i ght sour ces wi l l have f ai l ed and 50 per cent wi l l have sur vi ved under nor mal oper at i ng condi t i ons.

c. For LED l umi nai r e l i ght sour ces, " Usef ul Li f e" i s t he oper at i ng hour s bef or e r eachi ng 70 per cent of t he i ni t i al r at ed l umen out put ( L70) wi t h no cat ast r ophi c f ai l ur es under nor mal oper at i ng condi t i ons. Thi s i s al so known as 70 per cent " Rat ed Lumen Mai nt enance Li f e" as def i ned in I ES LM- 80.

d. The " Gr oundl i ne Sect i on" of wood pol es i s t hat por t i on of t he pol e bet ween one f oot above, and 2 f eet bel ow t he gr oundl i ne.

Apr i l 2019 Page 4 SECTI ON 26 56 00

1. 4 SUBMITTALS

Gover nment appr oval i s r equi r ed f or al l submi t t al s. . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL PROCEDURES:

SD- 01 Pr econst r uct i on Submi t t al s

Phot omet r i c Pl an

LED Lumi nai r e War r ant y

SD- 02 Shop Dr awi ngs

Lumi nai r e dr awi ngs

Poles

SD- 03 Pr oduct Dat a

HI D and LED Lumi nai r es

Lumi nai r e Li ght Sour ces

Lumi nai r e Bal l ast s and Power Suppl y Uni t s ( Dr i ver s)

Li ght i ng cont act or

Ti me swi t ch

Li ght i ng Cont r ol Rel ay Panel

Mot i on Sensor

Photocell

Concr et e pol es

Al umi num pol es

St eel pol es

Brackets

Obst r uct i on Mar ker Lumi nai r es

SD- 05 Desi gn Dat a

Desi gn Dat a f or l umi nai r es;

SD- 06 Test Repor t s

Oper at i ng t est

Submi t oper at i ng t est r esul t s as st at ed i n par agr aph ent i t l ed " Fi el d Qual i t y Cont r ol . "

Apr i l 2019 Page 5 SECTI ON 26 56 00

SD- 07 Cer t i f i cat es

Lumi nai r e Usef ul Li f e Cer t i f i cat e; G

Submi t cer t i f i cat i on f r om t he manuf act ur er i ndi cat i ng t he expect ed usef ul l i f e of t he l umi nai r es pr ovi ded. The usef ul l i f e shal l be di r ect l y cor r el at ed f r om t he I ES LM- 80 t est dat a usi ng pr ocedur es out l i ned i n I ES TM- 21. Ther mal pr oper t i es of t he speci f i c l umi nai r e and l ocal ambi ent oper at i ng t emper at ur e and condi t i ons shal l be t aken i nt o consi der at i on.

SD- 08 Manuf act ur er ' s I nst r uct i ons

Concr et e pol es

Submi t i nst r uct i ons pr i or t o i nst al l at i on.

SD- 10 Oper at i on and Mai nt enance Dat a

El ect r oni c Bal l ast War r ant y

1. 5 QUALI TY ASSURANCE

1. 5. 1 Dr awi ng Requi r ement s

1. 5. 1. 1 Lumi nai r e Dr awi ngs

I ncl ude di mensi ons, ef f ect i ve pr oj ect ed ar ea ( EPA) , accessor i es, and i nst al l at i on and const r uct i on det ai l s. Phot omet r i c dat a, i ncl udi ng zonal l umen dat a, aver age and mi ni mum r at i o, ai mi ng di agr am, and comput er i zed candl epower di st r i but i on dat a shal l accompany shop dr awi ngs.

1. 5. 1. 2 Poles

I ncl ude di mensi ons, wi nd l oad det er mi ned i n accor dance wi t h AASHTO LTS, pol e def l ect i on, pol e c l ass, and ot her appl i cabl e i nf or mat i on. For concr et e pol es, i ncl ude: sect i on and det ai l s t o i ndi cat e quant i t i es and posi t i on of pr est r essi ng st eel , spi r al st eel , i nser t s, and t hr ough hol es;

i ni t i al pr est r essi ng st eel t ensi on; and concr et e st r engt hs at r el ease and at 28 days.

1. 5. 2 Phot omet r i c Pl an

For LED l umi nai r es, i ncl ude comput er - gener at ed phot omet r i c anal ysi s of t he " desi gned t o" val ues f or t he " end of usef ul l i f e" of t he l umi nai r e i nst al l at i on usi ng a l i ght l oss f act or of 0. 7. For LED and al l ot her t ypes of l umi nai r es, t he submi t t al shal l i ncl ude t he f ol l owi ng:

Hor i zont al i l l umi nance measur ement s at f i ni shed gr ade, t aken at a maxi mum of ever y 10 f eet .

Ver t i cal i l l umi nance measur ement s at 5 f eet above f i ni shed gr ade.

Mi ni mum and maxi mum f oot candl e l evel s.

Apr i l 2019 Page 6 SECTI ON 26 56 00

Aver age mai nt ai ned f oot candl e l evel .

Maxi mum t o mi ni mum r at i o f or hor i zont al i l l umi nance onl y.

1. 5. 3 Desi gn Dat a f or Lumi nai r es

a. Pr ovi de di st r i but i on dat a accor di ng t o I ES cl assi f i cat i on t ype as def i ned i n I ES HB- 10.

b. Shi el di ng as def i ned by I ES RP- 8 or B. U. G. r at i ng f or t he i nst al l ed posi t i on as def i ned by I ES TM- 15.

c. Pr ovi de saf et y cer t i f i cat i on and f i l e number f or t he l umi nai r e f ami l y. I ncl ude l i s t i ng, l abel i ng and i dent i f i cat i on per NFPA 70 ( NEC) . Appl i cabl e t est i ng bodi es ar e det er mi ned by t he US Occupat i onal Saf et y Heal t h Admi ni st r at i on ( OSHA) as Nat i onal l y Recogni zed Test i ng Labor at or i es ( NRTL) and i ncl ude: CSA ( Canadi an St andar ds Associ at i on) , ETL ( Edi son Test i ng Labor at or y) , and UL ( Under wr i t er s Labor at or i es) .

d. Pr ovi de l ong t er m l umen mai nt enance pr oj ect i ons f or each LED l umi nai r e i n accor dance wi t h I ES TM- 21. Dat a used f or pr oj ect i ons shal l be obt ai ned f r om t est i ng i n accor dance wi t h I ES LM- 80.

e. Pr ovi de wi nd l oadi ng cal cul at i ons f or l umi nai r es mount ed on pol es.

Wei ght and ef f ect i ve pr oj ect ed ar ea ( EPA) of l umi nai r es and mount i ng br acket s shal l not exceed maxi mum r at i ng of pol e as i nst al l ed i n par t i cul ar wi nd zone ar ea.

1. 5. 4 Regul at or y Requi r ement s

I n each of t he publ i cat i ons r ef er r ed t o her ei n, consi der t he advi sor y pr ovi s i ons t o be mandat or y, as t hough t he wor d, " shal l " had been subst i t ut ed f or " shoul d" wher ever i t appear s. I nt er pr et r ef er ences i n t hese publ i cat i ons t o t he " aut hor i t y havi ng j ur i sdi ct i on, " or wor ds of s i mi l ar meani ng, t o mean t he Cont r act i ng Of f i cer . Equi pment , mat er i al s, i nst al l at i on, and wor kmanshi p shal l be i n accor dance wi t h t he mandat or y and advi sor y pr ovi s i ons of NFPA 70 unl ess mor e st r i ngent r equi r ement s ar e speci f i ed or i ndi cat ed.

1. 5. 5 St andar d Pr oduct s

Pr ovi de mat er i al s and equi pment t hat ar e pr oduct s of manuf act ur er s r egul ar l y engaged i n t he pr oduct i on of such pr oduct s whi ch ar e of equal mat er i al , desi gn and wor kmanshi p. Pr oduct s shal l have been i n sat i sf act or y commer ci al or i ndust r i al use f or 2 year s pr i or t o bi d openi ng. The 2- year per i od shal l i ncl ude appl i cat i ons of equi pment and mat er i al s under s i mi l ar c i r cumst ances and of s i mi l ar s i ze. The pr oduct shal l have been on sal e on t he commer ci al mar ket t hr ough adver t i sement s, manuf act ur er s ' cat al ogs, or br ochur es dur i ng t he 2- year per i od. Wher e t wo or mor e i t ems of t he same cl ass of equi pment ar e r equi r ed, t hese i t ems shal l be pr oduct s of a s i ngl e manuf act ur er ; however , t he component par t s of t he i t em need not be t he pr oduct s of t he same manuf act ur er unl ess st at ed i n t hi s sect i on.

1. 5. 5. 1 Al t er nat i ve Qual i f i cat i ons

Pr oduct s havi ng l ess t han a 2- year f i el d ser vi ce r ecor d wi l l be accept abl e

Apr i l 2019 Page 7 SECTI ON 26 56 00 i f t he manuf act ur er has been r egul ar l y engaged i n t he desi gn and pr oduct i on of hi gh i nt ensi t y di schar ge r oadway and ar ea l umi nai r es f or a mi ni mum of 15 year s. Pr oduct s shal l have been i n sat i sf act or y commer ci al or i ndust r i al use f or 15 year s pr i or t o bi d openi ng. The pr oduct shal l have been on sal e on t he commer ci al mar ket t hr ough adver t i sement s, manuf act ur er s ' cat al ogs, or br ochur es dur i ng t he 15- year per i od.

1. 5. 5. 2 Mat er i al and Equi pment Manuf act ur i ng Dat e

Pr oduct s manuf act ur ed mor e t han 1 year pr i or t o dat e of del i ver y t o s i t e shal l not be used, unl ess speci f i ed ot her wi se.

1. 6 DELI VERY, STORAGE, AND HANDLI NG OF POLES

1. 6. 1 Wood Pol es

Do not st or e pol es on gr ound. St ack pol es st or ed f or mor e t han 2 weeks on decay- r esi st i ng ski ds ar r anged t o suppor t t he pol es wi t hout pr oduci ng not i ceabl e di st or t i on. St or e pol es t o per mi t f r ee c i r cul at i on of ai r ; t he bot t om pol es i n t he st ack shal l be at l east one f oot above gr ound l evel and gr owi ng veget at i on. Do not per mi t decayed or decayi ng wood t o r emai n under neat h st or ed pol es. Do not dr ag t r eat ed pol es al ong t he gr ound. Do not use pol e t ongs, cant hooks, and ot her poi nt ed t ool s capabl e of pr oduci ng i ndent at i on mor e t han one i nch i n dept h i n handl i ng t he pol es.

Do not appl y t ool s t o t he gr oundl i ne sect i on of any pol e.

1. 6. 2 Concr et e Pol es

Do not st or e pol es on gr ound. Suppor t pol es so t hey ar e at l east one f oot above gr ound l evel and gr owi ng veget at i on.

1. 6. 3 Al umi num St eel Pol es

Do not st or e pol es on gr ound. Suppor t pol es so t hey ar e at l east one f oot above gr ound l evel and gr owi ng veget at i on. Do not r emove f act or y- appl i ed pol e wr appi ngs unt i l j ust bef or e i nst al l i ng pol e.

1. 7 WARRANTY

The equi pment i t ems shal l be suppor t ed by ser vi ce or gani zat i ons whi ch ar e r easonabl y conveni ent t o t he equi pment i nst al l at i on i n or der t o r ender sat i sf act or y ser vi ce t o t he equi pment on a r egul ar and emer gency basi s dur i ng t he war r ant y per i od of t he cont r act .

1. 7. 1 LED Lumi nai r e War r ant y

Pr ovi de Lumi nai r e Usef ul Li f e Cer t i f i cat e.

The equi pment i t ems shal l be suppor t ed by ser vi ce or gani zat i ons whi ch ar e r easonabl y conveni ent t o t he equi pment i nst al l at i on i n or der t o r ender sat i sf act or y ser vi ce t o t he equi pment on a r egul ar and emer gency basi s dur i ng t he war r ant y per i od of t he cont r act .

a. Pr ovi de a wr i t t en t en year on- si t e r epl acement war r ant y f or mat er i al , f i x t ur e f i ni sh, and wor kmanshi p. On- si t e r epl acement i ncl udes t r anspor t at i on, r emoval , and i nst al l at i on of new pr oduct s.

1. Fi ni sh war r ant y shal l i ncl ude war r ant y agai nst f ai l ur e and agai nst subst ant i al det er i or at i on such as bl i st er i ng, cr acki ng, peel i ng, Apr i l 2019 Page 8 SECTI ON 26 56 00 chal k i ng, or f adi ng.

2. Mat er i al war r ant y shal l i ncl ude:

( a) Al l power suppl y uni t s ( dr i ver s) .

( b) Repl acement when mor e t han 10 per cent of LED sour ces i n any l i ght bar or subassembl y( s) ar e def ect i ve or non- st ar t i ng.

b. War r ant y per i od must begi n on dat e of benef i c i al occupancy.

Cont r act or shal l pr ovi de t he Cont r act i ng Of f i cer s i gned war r ant y cer t i f i cat es pr i or t o f i nal payment .

1. 7. 2 El ect r oni c Bal l ast War r ant y

Fur ni sh t he el ect r oni c bal l ast s manuf act ur er ' s war r ant y. The war r ant y per i od shal l not be l ess t han f i ve ( 5) year s f r om t he dat e of manuf act ur e. Bal l ast assembl y i n t he l i ght i ng f i x t ur e, t r anspor t at i on, and on- si t e st or age shal l not exceed t wel ve ( 12) mont hs, t her eby per mi t t i ng f our ( 4) year s of t he f i ve ( 5) year war r ant y t o be i n ser vi ce and ener gi zed. The war r ant y shal l st at e t hat t he mal f unct i oni ng bal l ast shal l be exchanged by t he manuf act ur er and pr ompt l y shi pped t o t he usi ng Gover nment f aci l i t y . The r epl acement bal l ast shal l be i dent i cal t o, or an i mpr ovement upon, t he or i gi nal desi gn of t he mal f unct i oni ng bal l ast .

PART 2 PRODUCTS

2. 1 PRODUCT COORDI NATI ON

Pr oduct s and mat er i al s not consi der ed t o be l umi nai r es, equi pment or accessor i es ar e speci f i ed i n Sect i on 33 71 02 UNDERGROUND ELECTRI CAL DI STRI BUTI ON and Sect i on 26 20 00 I NTERI OR DI STRI BUTI ON SYSTEM. Lumi nai r es and associ at ed equi pment and accessor i es f or i nt er i or appl i cat i ons ar e speci f i ed i n Sect i on 26 51 00 I NTERI OR LI GHTI NG.

2. 2 HI D, AND LED LUMI NAI RES

UL 1598, NEMA C82. 77 and UL 8750. Pr ovi de l umi nai r es as i ndi cat ed i n l umi nai r e schedul e and XL pl at es or det ai l s on pr oj ect pl ans. Pr ovi de l umi nai r es compl et e wi t h l i ght sour ces of quant i t y, t ype, and wat t age i ndi cat ed. Al l l umi nai r es of t he same t ype shal l be pr ovi ded by t he same manufacturer.

2. 2. 1 Gener al Requi r ement s

a. LED l umi nai r e housi ngs shal l be di e cast or ext r uded al umi num.

Housi ngs f or l umi nai r es ot her t han LED shal l be di e cast , ext r uded, or f abr i cat ed al umi num. Fabr i cat ed al umi num housi ngs shal l have al l seams and cor ner s i nt er nal l y wel ded t o r esi st weat her i ng, moi st ur e and dust.

b. LED l umi nai r es shal l be r at ed f or oper at i on wi t hi n an ambi ent t emper at ur e r ange of mi nus 22 degr ees F t o 122 degr ees F.

c. Lumi nai r es shal l be UL l i s t ed f or wet l ocat i ons per UL 1598. Opt i cal compar t ment f or LED l umi nai r es shal l be seal ed and r at ed a mi ni mum of I P65 per NEMA I EC 60529.

Apr i l 2019 Page 9 SECTI ON 26 56 00

d. LED l umi nai r es shal l pr oduce a mi ni mum ef f i cacy as shown i n t he f ol l owi ng t abl e, t est ed per I ES LM- 79. Theor et i cal model s of i ni t i al r aw LED l umens per wat t ar e not accept abl e.

Application Lumi nai r e Ef f i cacy i n Lumens per Wat t

Ext er i or Pol e/ Ar m- Mount ed Ar ea and Roadway Luminaires

Ext er i or Pol e/ Ar m- Mount ed Decor at i ve Luminaires

Ext er i or Wal l - Mount ed Ar ea Lumi nai r es 60

Bollards 35

Par ki ng Gar age Lumi nai r es 70

e. Lumi nai r es shal l have I ES di st r i but i on and NEMA f i el d angl e c l assi f i cat i ons as i ndi cat ed i n l umi nai r e schedul e on pr oj ect pl ans per I ES HB- 10.

f . Housi ng f i ni sh shal l be baked- on enamel , anodi zed, or baked- on powder coat pai nt . Fi ni sh shal l be capabl e of sur vi v i ng ASTM B117 sal t f og envi r onment t est i ng f or 2500 hour s mi ni mum wi t hout bl i st er i ng or peeling.

g. Lumi nai r es shal l not exceed t he f ol l owi ng I ES TM- 15 Backl i ght , Upl i ght and Gl ar e ( B. U. G. ) r at i ngs:

1. Maxi mum Backl i ght ( B) r at i ng shal l be det er mi ned by l i ght i ng zone i n whi ch l umi nai r e i s pl aced.

2. Maxi mum Upl i ght ( U) r at i ng shal l be U0.

3. Maxi mum Gl ar e ( G) r at i ng shal l be det er mi ned by l i ght i ng zone i n whi ch l umi nai r e i s pl aced.

h. Lumi nai r es shal l be f ul l y assembl ed and el ect r i cal l y t est ed pr i or t o shi pment f r om f act or y.

i . The f i ni sh col or shal l be as i ndi cat ed i n t he l umi nai r e schedul e or det ai l on t he pr oj ect pl ans.

j . Lumi nai r e ar m bol t s shal l be 304 st ai nl ess st eel or z i nc- pl at ed st eel .

k. Lumi nai r e l enses shal l be const r uct ed of f r ost ed t emper ed gl ass or UV- r esi st ant acr yl i c. Pr ovi de pol ycar bonat e vandal - r esi st ant l enses as i ndi cat ed.

l . The wi r i ng compar t ment on pol e- mount ed, st r eet and ar ea l umi nai r es must be accessi bl e wi t hout t he use of hand t ool s t o mani pul at e smal l scr ews, bol t s, or har dwar e.

m. I ncor por at e modul ar el ect r i cal connect i ons, and const r uct l umi nai r es t o al l ow r epl acement of al l or any par t of t he opt i cs, heat s i nks, Apr i l 2019 Page 10 SECTI ON 26 56 00 power suppl y uni t s, bal l ast s, sur ge suppr essor s and ot her el ect r i cal component s usi ng onl y a s i mpl e t ool , such as a manual or cor dl ess el ect r i c scr ewdr i ver .

n. Lumi nai r es shal l have a namepl at e bear i ng t he manuf act ur er ' s name, addr ess, model number , dat e of manuf act ur e, and ser i al number secur el y af f i xed i n a conspi cuous pl ace. The namepl at e of t he di st r i but i ng agent wi l l not be accept abl e.

o. Roadway and ar ea l umi nai r es shal l have an i nt egr al t i l t adj ust ment of pl us or mi nus 5 degr ees t o al l ow t he uni t t o be l evel ed i n accor dance with ANSI C136. 3.

p. Lumi nai r e must pass 3G vi br at i on t est i ng i n accor dance wi t h

NEMA C136. 31.

q. Al l f act or y el ect r i cal connect i ons shal l be made usi ng cr i mp, l ocki ng, or l at chi ng st y l e connect or s. Twi st - st y l e wi r e nut s ar e not acceptable.

2. 2. 2 Lumi nai r e Li ght Sour ces

2. 2. 2. 1 Met al Hal i de ( MH) Li ght Sour ces

ANSI / ANSLG C78. 43, NEMA ANSLG C78. 44, ANSI C78. 1381, and NEMA ANSLG C78. 380.

Pr ovi de t ype and wat t age as i ndi cat ed i n l umi nai r e schedul e on pr oj ect pl ans. Open f i xt ur es ar e pr ohi bi t ed unl ess pr ovi ded wi t h a mechani sm t o ut i l i ze onl y Type O l i ght sour ces and pr ohi bi t t he use of Type E or S l i ght sour ces. Li ght sour ces shal l be speci f i cal l y sui t ed t o oper at e i n t he bur ni ng posi t i on whi ch t hey ar e i nst al l ed, and shal l be compl i ant wi t h t he most cur r ent TCLP t est pr ocedur e per NEMA C78. LL 3 at t he t i me of manufacture.

b. Al l pul se- st ar t met al hal i de l i ght sour ces shal l ut i l i ze an ED- t ype envel ope, E- 26 Medi um base, cer ami c ar c t ube t ype, r at ed wat t s and i ni t i al l umens as i ndi cat ed i n t he cont r act document s. Cor r el at ed col or t emper at ur e ( CCT) shal l be 3000 degr ees K, mi ni mum col or r ender i ng i ndex ( CRI ) shal l be 80, wi t h a mi ni mum aver age r at ed l i f e of 12, 000 hour s, based on 10 hour s oper at i on per st ar t .

2. 2. 2. 2 LED Li ght Sour ces

a. Cor r el at ed Col or Temper at ur e ( CCT) shal l be i n accor dance wi t h

NEMA ANSLG C78. 377:

Nomi nal CCT: 4000 degr ees K: 3985 pl us or mi nus 275 degr ees K

b. Col or Render i ng I ndex ( CRI ) shal l be:

Gr eat er t han or equal t o 70 f or 4000 degr ees K l i ght sour ces.

c. Col or Consi st ency:

Manuf act ur er shal l ut i l i ze a maxi mum 4- st ep MacAdam el l i pse bi nni ng t ol er ance f or col or consi st ency of LEDs used i n l umi nai r es.

Apr i l 2019 Page 11 SECTI ON 26 56 00

2. 2. 3 Lumi nai r e Bal l ast s and Power Suppl y Uni t s ( Dr i ver s)

2. 2. 3. 1 HI D Bal l ast s

2. 2. 3. 1. 1 El ect r oni c HI D Bal l ast s

NEMA ANSLG C82. 14, I EEE C62. 41, 47 CFR 18 and shal l meet t he f ol l owi ng requirements:

a. Mi ni mum power f act or shal l be gr eat er t han 90 per cent .

b. I nput vol t age shal l be 120- 277 vol t s pl us or mi nus 10 per cent .

c. Shal l have end of l i f e c i r cui t r y t o pr event bal l ast f r om oper at i ng i f l i ght sour ce i s i noper abl e.

d. Shal l have a sound r at i ng of A and a l amp cur r ent cr est f act or l ess t han 1. 5.

e. I nput cur r ent t ot al har moni c di st or t i on shal l be l ess t han 15 per cent .

f . Mi ni mum st ar t i ng t emper at ur e shal l be mi nus 22 degr ees F.

g. Shal l be t her mal l y pr ot ect ed t o pr event over heat i ng.

h. Shal l be UL l i s t ed and RoHS compl i ant .

2. 2. 3. 1. 2 Magnet i c HI D and LPS Bal l ast s

ANSI C82. 4. Pul se- st ar t const ant wat t age aut ot r ansf or mer ( CWA) t ype shal l be used when avai l abl e. Pr obe- st ar t const ant wat t age aut ot r ansf or mer ( CWA) , hi gh r eact ance/ hi gh power f act or ( HX- HPF) or r egul at or t ype shal l be used f or met al hal i de l i ght sour ces when pul se- st ar t i s not avai l abl e, and f or hi gh and l ow pr essur e sodi um l i ght sour ces. Bal l ast s shal l meet t he f ol l owi ng r equi r ement s:

a. Shal l have mi ni mum Cl ass " H" i nsul at i on r at i ng.

b. Shal l be desi gned f or 60, 000 hour s of oper at i on at maxi mum r at ed temperature.

c. Shal l have mi ni mum st ar t i ng t emper at ur e f or hi gh and l ow pr essur e sodi um shal l be mi nus 40 degr ees F, and f or met al hal i de mi nus 22 degr ees F.

d. Nomi nal bal l ast f act or shal l be 1. 0.

e. Capaci t or s shal l have a sel f - cont ai ned bl eeder r esi st or as r equi r ed by

UL 1029.

f . Oi l - f i l l ed capaci t or s shal l be housed i n an al umi num or cor r osi on- r esi st ant st eel can and be pr ovi ded wi t h 0. 25 i n qui ck di sconnect t er mi nal s.

g. Capaci t or maxi mum case t emper at ur e shal l be 194 degr ees F f or oi l - f i l l ed and 221 degr ees F f or dr y f i l m t ype.

h. St ar t er / i gni t er shal l pr ovi de si x mont hs of l i ght sour ce open ci r cui t

Apr i l 2019 Page 12 SECTI ON 26 56 00 oper at i on wi t hout f ai l ur e and be desi gned t o wi t hst and 10, 000 hour s of cont i nuous pul s i ng ( not appl i cabl e f or LPS) .

2. 2. 3. 2 LED Power Suppl y Uni t s ( Dr i ver s)

UL 1310. LED Power Suppl y Uni t s ( Dr i ver s) shal l meet t he f ol l owi ng requirements:

a. Mi ni mum ef f i c i ency shal l be 85 per cent .

b. Dr i ve cur r ent t o each i ndi v i dual LED shal l not exceed 600 mA, pl us or mi nus 10 per cent .

c. Shal l be r at ed t o oper at e bet ween ambi ent t emper at ur es of mi nus 22 degr ees F and 122 degr ees F.

d. Shal l be desi gned t o oper at e on t he vol t age syst em t o whi ch t hey ar e connect ed, t ypi cal l y r angi ng f r om 120 V t o 480 V nomi nal .

e. Oper at i ng f r equency shal l be: 50 or 60 Hz.

f . Power Fact or ( PF) shal l be gr eat er t han or equal t o 0. 90.

g. Tot al Har moni c Di st or t i on ( THD) cur r ent shal l be l ess t han or equal t o 20 per cent .

h. Shal l meet r equi r ement s of 47 CFR 15, Cl ass B.

i . Shal l be RoHS- compl i ant .

j . Shal l be mount ed i nt egr al t o l umi nai r e. Remot e mount i ng of power suppl y i s not al l owed.

k. Power suppl i es i n l umi nai r es mount ed under a cover ed st r uct ur e, such as a canopy, or wher e ot her wi se appr opr i at e shal l be UL l i s t ed wi t h a sound r at i ng of A.

m. Shal l be equi pped wi t h over - t emper at ur e pr ot ect i on c i r cui t t hat t ur ns l i ght sour ce of f unt i l nor mal oper at i ng t emper at ur e i s achi eved.

2. 2. 4 LED Lumi nai r e Sur ge Pr ot ect i on

Pr ovi de sur ge pr ot ect i on i nt egr al t o l umi nai r e t o meet C Low wavef or ms as def i ned by I EEE C62. 41. 2, Scenar i o 1, Locat i on Cat egor y C.

2. 3 OBSTRUCTI ON MARKER LUMI NAI RES

Pr ovi de obst r uct i on mar ker l umi nai r es f or f aci l i t i es as r equi r ed by t he FAA and i n accor dance wi t h UFC 3- 260- 01 and UFC 3- 535- 01.

2. 4 EXTERI OR LUMI NAI RE CONTROLS

Cont r ol s shal l compl y wi t h Sect i on 9 of ASHRAE 90. 1 - I P .

2. 4. 1 Photocell

UL 773 or UL 773A. Phot ocel l s shal l be her met i cal l y seal ed, cadmi um sul f i de or s i l i con di ode l i ght sensor t ype, r at ed wat t age and vol t age as

Apr i l 2019 Page 13 SECTI ON 26 56 00 i ndi cat ed or as appr opr i at e t o t he appl i cat i on, 50/ 60 Hz wi t h s i ngl e- pol e, s i ngl e or doubl e- t hr ow cont act s as appr opr i at e. Phot ocel l shal l be desi gned t o f ai l t o t he ON posi t i on. Housi ng shal l be const r uct ed of di e cast al umi num, r at ed t o oper at e wi t hi n a t emper at ur e r ange of mi nus 40 t o 158 degr ees F. Phot ocel l shal l have a 1/ 2 i n t hr eaded base f or mount i ng t o a j unct i on box or condui t . Pr ovi de swi vel base t ype housi ng. Phot ocel l shal l t ur n on at 1- 3 f oot candl es and t ur n of f at 3 t o 15 f oot candl es. A t i me del ay shal l pr event acci dent al swi t chi ng f r om t r ansi ent l i ght sour ces.

Pr ovi de a di r ect i onal l ens i n f r ont of t he cel l t o pr event f i xed l i ght sour ces f r om cr eat i ng a t ur nof f condi t i on. Pr ovi de phot ocel l wi t h met al oxi de var i st or ( MOV) t ype sur ge pr ot ect i on.

2. 4. 2 Timeswitch

Ti meswi t ch shal l be an el ect r oni c t ype wi t h a 24 hour 7 day ast r onomi c pr ogr ammi ng f unct i on t hat changes on/ of f set t i ngs accor di ng t o seasonal var i at i ons of sunset and sunr i se, pr ovi di ng a t ot al of 56 on/ of f set poi nt s. Di gi t al c l ock di spl ay f or mat shal l be24 hour t ype. Pr ovi de power out age backup f or swi t ch whi ch pr ovi des cover age f or a mi ni mum of 7 days.

Ti meswi t ch shal l pr ovi de cont r ol t o 4 channel s or l oads. Cont act s shal l be r at ed f or 30 amps at 120- 277 VAC r esi st i ve l oad i n a conf i gur at i on appr opr i at e t o t he appl i cat i on. Pr ovi de swi t ch wi t h f unct i on t hat al l ows aut omat i c cont r ol t o be ski pped on cer t ai n sel ect ed days of t he week, manual bypass or r emot e over r i de cont r ol , dayl i ght savi ngs t i me aut omat i c adj ust ment , EEPROM memor y modul e, moment ar y f unct i on f or out put cont act s, and abi l i t y f or phot osensor i nput .

Ti meswi t ch shal l be housed i n a sur f ace- mount ed, l ockabl e NEMA 3R encl osur e const r uct ed of pai nt ed st eel or pl ast i c pol ymer conf or mi ng t o

NEMA I CS 6.

2. 4. 3 Li ght i ng Cont act or

NEMA I CS 2. Pr ovi de a mechani cal l y- hel d l i ght i ng cont act or housed i n a NEMA 3R encl osur e conf or mi ng t o NEMA I CS 6. Cont act or shal l have 4 pol es, conf i gur ed as nor mal l y open ( NO) . Cont act s shal l be r at ed 600 vol t s, 30 amper es f or a r esi st i ve l oad. Coi l oper at i ng vol t age shal l be 277 vol t s.

Cont act or shal l have si l ver cadmi um oxi de doubl e- br eak cont act s and coi l c l ear i ng cont act s f or mechani cal l y hel d cont act or s and shal l r equi r e no ar ci ng cont act s. Pr ovi de cont act or wi t h hand- of f - aut omat i c on- of f sel ect or swi t ch.

2. 4. 4 Li ght i ng Cont r ol Rel ay Panel

Panel shal l consi st of a s i ngl e NEMA 1 or 3R, f l ush or sur f ace- mount ed encl osur e, as speci f i ed, wi t h t wo separ at e i nt er i or sect i ons; one f or Cl ass 1 br anch ci r cui t and one f or Cl ass 2 l ow vol t age wi r i ng. Pr ovi de panel wi t h number of r el ays as speci f i ed. Panel shal l be desi gned as a st and al one or an aut omat ed cont r ol syst em i nt er f ace t ype. The Cl ass 1 sect i on shal l cont ai n t he l oad si de of al l r el ays and t he i ncomi ng br anch ci r cui t wi r i ng. The Cl ass 2 sect i on shal l cont ai n t he cont r ol power t r ansf or mer ( 24 vol t out put ) , r el ays, r el ay cont r ol modul es, and cont r ol wi r i ng, and nat i ve BACnet or LONwor ks f i el d- pr ogr ammabl e appl i cat i on cont r ol l er f or panel s connect ed t o t he f aci l i t y aut omat ed cont r ol syst em.

Panel encl osur e shal l be const r uct ed of 14 gauge col d- r ol l ed st eel wi t h baked- on enamel f i ni sh. Panel shal l meet r equi r ement s of ASHRAE 90. 1 - I P and 47 CFR 15.

Rel ays shal l be 1 or 2- pol e, r at ed at 20 amper es 480 VAC wi t h r at ed l i f e

Apr i l 2019 Page 14 SECTI ON 26 56 00 of 120, 000 mechani cal oper at i ons mi ni mum.

Rel ay cont r ol modul e shal l be 24 vol t , el ect r oni c t ype and cont r ol up t o 16 separ at e r el ays ( 16 channel ) or pr ogr ammed gr oups of r el ays. Pr ovi de wi t h i nput s f or s i gnal s f r om devi ces such as phot ocel l s, t i mecl ocks, and mot i on sensor s. Rel ay cont r ol modul e wi t h i nt egr al t i mecl ock f unct i on shal l be 24 vol t , el ect r oni c t ype wi t h LCD di spl ay and cont r ol up t o 8 separ at e r el ays ( 8 channel ) . 2. 4. 5 Mot i on Sensor

NEMA WD 7, UL 773A. Pr ovi de dual t echnol ogy passi ve i nf r ar ed/ mi cr owave t ype sensor s wi t h 270 degr ee cover age, t i me del ay t hat can be adj ust ed f r om 15 seconds t o 15 mi nut es, and " f ai l t o ON posi t i on" def aul t st at e.

Sensor s shal l be l ocat ed t o achi eve cover age of ar eas as i ndi cat ed on pr oj ect pl ans. Cover age pat t er ns shal l be der at ed as r ecommended by manuf act ur er based on mount i ng hei ght of sensor and any obst r uct i ons such as t r ees. Do not use gr oss r at ed cover age i n manuf act ur er ' s pr oduct l i t er at ur e. Sensor s i nst al l ed i nt egr al t o t he l umi nai r e must be pr ovi ded by t he l umi nai r e manuf act ur er . Sensor s shal l have an i nt egr al l i ght l evel sensor t hat does not al l ow l umi nai r es t o oper at e dur i ng dayl i ght hour s and shal l be desi gned t o oper at e on a vol t age of 120/ 277 VAC. Sensor shal l be equi pped wi t h a t hr eaded base f or mount i ng t o a weat her pr oof j unct i on box.

2. 5 POLES

Pr ovi de pol es desi gned f or wi nd l oadi ng of 100 mi l es per hour det er mi ned i n accor dance wi t h AASHTO LTS whi l e suppor t i ng l umi nai r es and al l ot her appur t enances i ndi cat ed. The ef f ect i ve pr oj ect ed ar eas of l umi nai r es and appur t enances used i n cal cul at i ons shal l be speci f i c f or t he act ual pr oduct s pr ovi ded on each pol e. Pol es shal l be anchor - base t ype desi gned f or use wi t h under gr ound suppl y conduct or s. Pol es, ot her t han wood pol es, shal l have oval - shaped handhol e havi ng a mi ni mum cl ear openi ng of 2. 5 by 5 i nches. Handhol e cover shal l be secur ed by st ai nl ess st eel capt i ve scr ews.

Met al pol es shal l have an i nt er nal gr oundi ng connect i on accessi bl e f r om t he handhol e near t he bot t om of each pol e. Scr at ched, st ai ned, chi pped, or dent ed pol es shal l not be i nst al l ed.

2. 5. 1 Concr et e Pol es

Pr ovi de concr et e pol es conf or mi ng t o ASTM C1089. Cr oss- sect i onal shape shal l be mul t i - s i ded.

2. 5. 1. 1 St eel Rei nf or ci ng

Pr est r essed concr et e pol e shaf t s shal l be r ei nf or ced wi t h st eel pr est r essi ng member s. Desi gn shal l pr ovi de i nt er nal l ongi t udi nal l oadi ng by ei t her pr et ensi oni ng or post t ensi oni ng of l ongi t udi nal r ei nf or ci ng members.

2. 5. 1. 2 Tensi oned Rei nf or ci ng

Pr i mar y r ei nf or cement st eel used f or a pr est r essed concr et e pol e shaf t shal l be t ensi oned bet ween 60 t o 70 per cent of i t s ul t i mat e st r engt h. The amount of r ei nf or cement shal l be such t hat when r ei nf or cement i s t ensi oned t o 70 per cent of i t s ul t i mat e st r engt h, t he t ot al r esul t ant t ensi l e f or ce does not exceed t he mi ni mum sect i on compr essi ve st r engt h of t he concr et e.

2. 5. 1. 3 Coat i ng and Sl eeves f or Rei nf or ci ng Member s

Wher e mi ni mum i nt er nal cover age cannot be mai nt ai ned next t o r equi r ed cor e

Apr i l 2019 Page 15 SECTI ON 26 56 00 openi ngs, such as handhol e and wi r i ng i nl et , r ei nf or ci ng shal l be pr ot ect ed wi t h a vapor pr oof noncor r osi ve s l eeve over t he l engt h wi t hout t he 1/ 2 i nch concr et e cover age. Each st eel r ei nf or ci ng member whi ch i s t o be post - t ensi oned shal l have a nonmi gr at i ng s l i pper coat i ng appl i ed pr i or t o t he addi t i on of concr et e t o ensur e uni f or mi t y of st r ess t hr oughout t he l engt h of such member .

2. 5. 1. 4 St r engt h Requi r ement

As an except i on t o t he r equi r ement s of ASTM C1089, pol es shal l be nat ur al l y cur ed t o achi eve a 28- day compr essi ve st r engt h of 7000 psi .

Pol es shal l not be subj ect ed t o sever e t emper at ur e changes dur i ng t he cur i ng per i od.

2. 5. 1. 5 Shaf t Pr epar at i on

Compl et ed pr est r essed concr et e pol e shaf t shal l have a har d, smoot h, nonpor ous sur f ace t hat i s r esi st ant t o soi l aci ds, r oad sal t s, and at t acks of wat er and f r ost , and shal l be c l ean, smoot h, and f r ee of sur f ace voi ds and i nt er nal honeycombi ng. Pol es shal l not be i nst al l ed f or at l east 15 days af t er manuf act ur e.

2. 5. 2 Al umi num Pol es

Pr ovi de al umi num pol es manuf act ur ed of cor r osi on r esi st ant al umi num al l oys conf or mi ng t o AASHTO LTS f or Al l oy 6063- T6 or Al l oy 6005- T5 f or wr ought al l oys and Al l oy 356- T4 ( 3, 5) f or cast al l oys. Pol es shal l be seaml ess ext r uded or spun seaml ess t ype wi t h mi ni mum 0. 188 i nch wal l t hi ckness.

Pr ovi de a pol e gr oundi ng connect i on desi gned t o pr event el ect r ol ysi s when used wi t h copper gr ound wi r e. Tops of shaf t s shal l be f i t t ed wi t h a r ound or t aper ed cover . Base shal l be anchor bol t mount ed, made of cast 356- T6 al umi num al l oy i n accor dance wi t h ASTM B108/ B108M and shal l be machi ned t o r ecei ve t he l ower end of shaf t . Joi nt bet ween shaf t and base shal l be wel ded. Base cover shal l be cast 356- T6 al umi num al l oy i n accor dance wi t h ASTM B108/ B108M. Har dwar e, except anchor bol t s, shal l be ei t her 2024- T4 anodi zed al umi num al l oy or st ai nl ess st eel . Al umi num pol es and br acket s f or wal kway l i ght i ng shal l have a uni f or m sat i n dar k anodi c br onze f i ni sh t o mat ch f i xt ur es and shal l not be pai nt ed. Manuf act ur er ' s st andar d pr ovi s i on shal l be made f or pr ot ect i ng t he f i ni sh dur i ng shi pment and i nst al l at i on. Mi ni mum pr ot ect i on shal l consi st of spi r al l y wr appi ng each pol e shaf t wi t h pr ot ect i ve paper secur ed wi t h t ape, and shi ppi ng smal l par t s i n boxes.

2. 5. 3 St eel Pol es

AASHTO LTS. Pr ovi de st eel pol es havi ng mi ni mum 11- gage st eel wi t h mi ni mum yi el d/ st r engt h of 48, 000 psi and hot - di pped gal vani zed i n accor dance wi t h ASTM A123/ A123M or i r on- oxi de pr i med f act or y f i ni sh. Pr ovi de a pol e gr oundi ng connect i on desi gned t o pr event el ect r ol ysi s when used wi t h copper gr ound wi r e. Pol e shal l be anchor bol t mount ed t ype. Pol es shal l have t aper ed t ubul ar member s, ei t her r ound i n cr oss sect i on or pol ygonal .

Pol e shaf t s shal l be one pi ece. Pol es shal l be wel ded const r uct i on wi t h no bol t s, r i vet s, or ot her means of f ast eni ng except as speci f i cal l y appr oved. Pol e mar ki ngs shal l be appr oxi mat el y 3 t o 4 f eet above gr ade and shal l i ncl ude manuf act ur er , year of manuf act ur e, t op and bot t om di amet er s, and l engt h. Base cover s f or st eel pol es shal l be st r uct ur al qual i t y hot - r ol l ed car bon st eel pl at e havi ng a mi ni mum yi el d of 36, 000 psi .

Apr i l 2019 Page 16 SECTI ON 26 56 00

2. 5. 4 Wood Pol es

ATI S ANSI O5. 1 and RUS Bul l 1728F- 700 of Sout her n Yel l ow Pi ne or Dougl as Fi r . Pol es shal l be gai ned, bor ed, and r oof ed bef or e t r eat ment . Pol es shal l be t r eat ed f ul l l engt h wi t h chr omat ed copper ar senat e ( CCA) or ammoni acal copper ar senat e ( ACA) accor di ng t o AWPA U1 as r ef er enced i n RUS Bul l 1728F- 700. Pol es shal l be br anded by manuf act ur er wi t h manuf act ur er ' s mar k and dat e of t r eat ment , hei ght and cl ass of pol e, wood speci es, pr eser vat i on code, and r et ent i on. Pl ace t he br and so t hat t he bot t om of t he br and or di sc i s 10 f eet f r om t he pol e but t f or pol es up t o 50 f eet l ong.

2. 6 BRACKETS AND SUPPORTS

ANSI C136. 3, ANSI C136. 13, and ANSI C136. 21, as appl i cabl e. Pol e br acket s shal l be not l ess t han 1 1/ 4 i nch gal vani zed st eel pi pe or al umi num secur ed t o pol e. Sl i p- f i t t er or pi pe- t hr eaded br acket s may be used, but br acket s shal l be coor di nat ed t o l umi nai r es pr ovi ded, and br acket s f or use wi t h one t ype of l umi nai r e shal l be i dent i cal . Br acket s f or pol e- mount ed st r eet l i ght s shal l cor r ect l y posi t i on l umi nai r e no l ower t han mount i ng hei ght i ndi cat ed. Mount br acket s not l ess t han 24 f eet above st r eet .

Speci al mount i ngs or br acket s shal l be as i ndi cat ed and shal l be of met al whi ch wi l l not pr omot e gal vani c r eact i on wi t h l umi nai r e head.

2. 7 POLE FOUNDATI ONS

Anchor bol t s shal l be st eel r od havi ng a mi ni mum yi el d st r engt h of 50, 000 psi ; t he t op 12 i nches of t he r od shal l be gal vani zed i n accor dance wi t h ASTM A153/ A153M. Concr et e shal l be as speci f i ed i n Sect i on 03 30 00

CAST- I N- PLACE CONCRETE.

2. 8 EQUI PMENT I DENTI FI CATI ON

2. 8. 1 Manuf act ur er ' s Namepl at e

Each i t em of equi pment shal l have a namepl at e bear i ng t he manuf act ur er ' s name, addr ess, model number , and ser i al number secur el y af f i xed i n a conspi cuous pl ace; t he namepl at e of t he di st r i but i ng agent wi l l not be acceptable.

2. 8. 2 Labels

Pr ovi de l abel ed l umi nai r es i n accor dance wi t h UL 1598 r equi r ement s.

Lumi nai r es shal l be c l ear l y mar ked f or oper at i on of speci f i c l i ght sour ces and bal l ast s accor di ng t o pr oper l i ght sour ce t ype. The f ol l owi ng l i ght sour ce char act er i st i cs shal l be not ed i n t he f or mat " Use Onl y _____" :

b. Li ght sour ce t ype, wat t age, bul b t ype ( e. g. ED17, BD56) and coat i ng ( c l ear or coat ed) f or HI D l umi nai r es.

d. ANSI bal l ast t ype ( e. g. M98, M57) f or HI D l umi nai r es.

e. Cor r el at ed col or t emper at ur e ( CCT) and col or r ender i ng i ndex ( CRI ) f or al l l umi nai r es.

Mar ki ngs r el at ed t o l amp t ype shal l be c l ear and l ocat ed t o be r eadi l y v i s i bl e t o ser vi ce per sonnel , but unseen f r om nor mal v i ewi ng angl es when l amps ar e i n pl ace. Bal l ast s shal l have cl ear mar ki ngs i ndi cat i ng mul t i - l evel out put s and i ndi cat e pr oper t er mi nal s f or t he var i ous out put s.

Apr i l 2019 Page 17 SECTI ON 26 56 00

2. 9 FACTORY APPLI ED FI NI SH

El ect r i cal equi pment shal l have f act or y- appl i ed pai nt i ng syst ems whi ch shal l , as a mi ni mum, meet t he r equi r ement s of NEMA 250 cor r osi on- r esi st ance t est .

PART 3 EXECUTI ON

3. 1 INSTALLATION

El ect r i cal i nst al l at i ons shal l conf or m t o I EEE C2, NFPA 70, and t o t he r equi r ement s speci f i ed her ei n.

3. 1. 1 Wood Pol es

Pol e hol es shal l be at l east as l ar ge at t he t op as at t he bot t om and shal l be l ar ge enough t o pr ovi de 4 i nches of c l ear ance bet ween t he pol e and t he si de of t he hol e.

a. Set t i ng dept h: Pol e set t i ng dept hs shal l be as f ol l ows:

Lengt h of Pol e ( f eet ) Set t i ng i n Soi l ( f eet )

20 5.0

25 5.5

30 5.5

35 6.0

40 6.0

45 6.5

50 7.0

55 7.5

60 8.0

b. Soi l set t i ng: " Set t i ng i n Soi l " dept hs shal l appl y wher e pol e hol es ar e i n soi l , sand, or gr avel or any combi nat i on of t hese. At cor ner s, dead ends and ot her poi nt s of ext r a st r ai n, pol es 40 f eet l ong or mor e shal l be set 6 i nches deeper .

c. Set t i ng on sl opi ng gr ound: On sl opi ng gr ound, measur e t he dept h of t he hol e f r om t he l ow si de of t he hol e.

d. Backf i l l : Tamp pol e backf i l l f or t he f ul l dept h of t he hol e and mound t he excess f i l l ar ound t he pol e.

3. 1. 2 Concr et e Pol es

I nst al l accor di ng t o pol e manuf act ur er ' s i nst r uct i ons.

Apr i l 2019 Page 18 SECTI ON 26 56 00

3. 1. 3 Al umi num / St eel Pol es

Pr ovi de pol e f oundat i ons wi t h gal vani zed st eel anchor bol t s, t hr eaded at t he t op end and bent 90 degr ees at t he bot t om end. Pr ovi de or nament al cover s t o mat ch pol e and gal vani zed nut s and washer s f or anchor bol t s.

Concr et e f or anchor bases, pol yvi nyl chl or i de ( PVC) condui t el l s , and gr ound r ods shal l be as speci f i ed i n Sect i on 33 71 02 UNDERGROUND ELECTRI CAL DI STRI BUTI ON. Thor oughl y compact backf i l l wi t h compact i ng ar r anged t o pr event pr essur e bet ween conduct or , j acket , or sheat h and t he end of condui t el l . Adj ust pol es as necessar y t o pr ovi de a per manent ver t i cal posi t i on wi t h t he br acket ar m i n pr oper posi t i on f or l umi nai r e l ocat i on. Af t er i nst al l at i on, pai nt exposed sur f aces of st eel pol es wi t h t wo f i ni sh coat s of ext er i or oi l pai nt of a col or as i ndi cat ed. I nst al l accor di ng t o pol e manuf act ur er ' s i nst r uct i ons. Al t er at i ons t o pol es af t er f abr i cat i on wi l l voi d manuf act ur er ' s war r ant y and shal l not be al l owed.

3. 1. 4 Pol e Set t i ng

Dept h shal l be as i ndi cat ed. Pol es i n st r ai ght r uns shal l be i n a st r ai ght l i ne. Di g hol es l ar ge enough t o per mi t t he pr oper use of t amper s t o t he f ul l dept h of t he hol e. Pl ace backf i l l i n t he hol e i n 6 i nch maxi mum l ayer s and t hor oughl y t amp. Pl ace sur pl us ear t h ar ound t he pol e i n a coni cal shape and pack t i ght l y t o dr ai n wat er away.

3. 1. 5 Phot ocel l Swi t ch Ai mi ng

Ai m swi t ch accor di ng t o manuf act ur er ' s r ecommendat i ons. Mount swi t ch on or besi de each l umi nai r e when swi t ch i s pr ovi ded i n cast weat her pr oof al umi num housi ng wi t h swi vel ar m.

3. 1. 6 GROUNDING

Gr ound noncur r ent - car r y i ng par t s of equi pment i ncl udi ng met al pol es, l umi nai r es, mount i ng ar ms, br acket s, and met al l i c encl osur es as speci f i ed i n Sect i on 33 71 02 UNDERGROUND ELECTRI CAL DI STRI BUTI ON. Wher e copper gr oundi ng conduct or i s connect ed t o a met al ot her t han copper , pr ovi de speci al l y t r eat ed or l i ned connect or s sui t abl e f or t hi s pur pose.

3. 1. 7 FI ELD APPLI ED PAI NTI NG

Pai nt el ect r i cal equi pment as r equi r ed t o mat ch f i ni sh of adj acent sur f aces or t o meet t he i ndi cat ed or speci f i ed saf et y cr i t er i a. Pai nt i ng shal l be as speci f i ed i n Sect i on 09 90 00 PAI NTS AND COATI NGS.

3. 2 FI ELD QUALI TY CONTROL

Upon compl et i on of i nst al l at i on, ver i f y t hat equi pment i s pr oper l y i nst al l ed, connect ed, and adj ust ed. Conduct an oper at i ng t est af t er 100 hour s of bur n- i n t i me t o show t hat t he equi pment oper at es i n accor dance wi t h t he r equi r ement s of t hi s sect i on.

- - End of Sect i on - -