These are architectural and engineering drawings for a unit substation and switchgear replacement project at Tinker Air Force Base, Oklahoma. The project involves replacing the existing 12470V primary load switch, a 1000kVA transformer, and the 480/277V switchboard in Building 3001, Column V51. The drawings include detailed mechanical and electrical demolition plans, equipment layout diagrams, symbols legends, and a site location map. Key requirements include installing a new cage ladder at a location to be coordinated with the user, adding a remote control panel, and ensuring compliance with NEC and NFPA standards. The project is limited to Tinker AFB Multiple Award Contract (MAC) BOA holders, with an initial site visit scheduled for 15 April 2025 from 10:30-11:30 AM CT, requiring construction personal protective equipment (PPE) for attendance. Interested contractors must RSVP by 14 April 2025 at 12:00 PM, including an Entry Access List if base access is needed.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REVIEWED BY:
REVIEWED BY:
USING AGENCY:
ASBESTOS EVALUATION:
SAFETY:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
INDUSTRIAL HYGIENE:
DATE:
PROJECT DRAWING INDEX SIGNATURES
CORROSION ENGINEER: (CECE)
CE OPERATIONS: (CECO)
COMMUNICATIONS: (COMM)
CHIEF ENGINEER DIR: (CECE)
CHIEF DESIGN BRANCH: (CECE)
DESIGN MANAGER: (CECE)
ZONE MANAGER:
CONSTRUCTION MANAGEMENT: (CECE)
ENVIRONMENTAL:
BASE CIVIL ENGINEER: (CE)
FIRE DEPARTMENT: (CEFT)
GENERAL1. BRAND NAMES: REFERENCE TO SPECIFIC BRAND NAMES
OR COMPANIES IS FOR THE PURPOSE OF ESTABLISHING
MINIMUM QUALITY STANDARDS, IDENTIFICATION AND
GUIDANCE AND IS NOT INTENDED TO LIMIT SELECTION OF
OTHER MANUFACTURERS THAT ARE EQUAL OR EXCEED
THE SPECIFIED ITEMS IN TERMS OF PHYSICAL
PROPERTIES, INCLUDING, COLOR RANGE, FINISH,
DURABILITY, APPEARANCE, PERFORMANCE
CHARACTERISTICS, AND OTHER FACTORS. OTHER
PRODUCTS, MATERIALS, COLORS AND SYSTEMS, MAY BE
SUBMITTED FOR EVALUATION AND
APPROVAL/DISAPPROVAL BY THE CONTRACTING OFFICER.
2. THIS SET OF CONSTRUCTION DOCUMENTS SHALL BE
CONSIDERED AS A WHOLE IN THAT THE GENERAL
CONTRACTOR AND ALL THE SUB-CONTRACTORS ARE
RESPONSIBLE FOR THE INFORMATION PRESENTED ON ALL
SHEETS ON THE SET OF DRAWINGS AND ALL SECTIONS OF
THE SPECIFICATIONS.
3. THE CONTRACTOR IS RESPONSIBLE FOR ERECTING ALL
CONSTRUCTION FENCING AND BARRICADES AS REQUIRED
TO PROTECT CONSTRUCTION MATERIAL AND TO PREVENT
ANY UNAUTHORIZED PERSONNEL FROM ENTERING THE
CONSTRUCTION SITE.
4. ANY DAMAGE TO THE EXISTING GROUNDS OR FACILITIES
CAUSED BY CONSTRUCTION TRAFFIC OR ANY
CONSTRUCTION OPERATION SHALL BE REPAIRED OR
REPLACED BY THE CONTRACTOR TO MATCH OR EXCEED
EXISTING CONDITIONS AT NO ADDITIONAL COST TO THE
GOVERNMENT.
5. ALL WORK NOTED & LOCATED IN THESE DOCS SHALL BE
UNDERSTOOD BY THE CONTRACTOR TO REQUIRE ALL NEW
LABOR & MATERIALS UNLESS SPECIFICALLY NOTED TO BE
"EXISTING" OR "BY OTHERS".
WWYK140020, WO 52142
REPLACE UNIT SUBSTATION
& SWITCHGEAR COL V51
B3001
KEY PLAN:
GENERAL NOTES:
DISCIPLINE
PROJECT
LOCATION
1 G-101 GENERAL NOTES & VICINITY MAP
SHT.SEQ. SHEET TITLE
OF
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
(SOW)
W W
YK
, W O
RE
PL
AC
E
UN
IT
S
UB
ST
AT
IO
N
SW
IT
CH
GE
AR
C
OL
V
B3
M
AR
TE
PA
-C
SA
G
S
SE
XT
O
N
G-101
T
KI
SE
R
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
0\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
GE
NE
RA
L N
OT
ES
AN
D
VI
CI
NI
TY
M
AP
E-001 ELECTRICAL SYMBOLS LEGEND AND ABBREVIATIONS
ED-101 ELECTRICAL DEMOLITION PLAN
E-101 ELECTRICAL PLAN
MD-101 MECHANICAL DEMOLITION PLAN
M-101 MECHANICAL PHOTOS
R U
N W
AY
8/
RUNWAY 13/31
TA
XI
W
AY
G
TAXIW
AY H
TAXIWAY B
TAXIWAY C
TAXIWAY M
TA
XI
W
AY
K
TAXIWAY E
TAXIWAY A
TA
XIW
AY E
E
TAXIWAY F
TAXIWAY D
TAXIWAY E
TAXIWAY J
TA
XI
W
AY
G
TAXIWAY A
TAXIW
AY H
TAXIWAY C
TAXIWAY D
TAXIWAY EE
TAXIWAY F
Elm C reek
Cr ut ch o
Cr ee k
Kuhlman Creek
Soldier Creek
Kuhlman Creek
Elm C reek
East Crutcho Creek
Elm Creek
El m
C re ek
Elm Creek
Elm C reek
Elm CreekElm C reek
Ku hlm an C re ek
Ea st
C ru tc ho
C re ek
Elm C ree k
West Crutcho Creek
W es t C ru tc ho
C re ek
Elm Creek
Soldier Creek
Elm C reek
Soldier CreekSoldier Creek
Ea st
C ru tc ho
C re ek
Elm Creek
Ea st
C ru tc ho
C re ek
East C rutcho C reek
Soldier Creek
So ld ie r C re ek
East C rutch o Creek
Soldier C reek
Soldier C reek
So ld ie r C re ek
East Crutcho Creek
416506
21222121
59475946
11401128
62540
61089
838837
62509
62528
62523
62501X
43774
62512
62516
62525
3592135916
99999
62543
32101
71086
53902
50414
55300
56601
930G
948-E
911-E
948-W
61019
911-W
33001
35913
62501
65672
930S
45134
43609
42116
62517
62515
62526
62527
62503
62513
61289
62542
62501OK
11289
62501
15930
15908
15904
15904
15908
15908
15904
15904
15908
62502
41046
62501
62514
62501
61018
71089
45134
96022
43120
41157
44045
45815
40592
43610
62522
41163
15930
15930
11824
Arnold St.
Ea st
D r.
SE 74th St
SE 59th St.
Ai r D ep ot
Patrol Rd.
St af f D r.
Reserve Rd.
5th Ave
"A " A ve
M un iti on s R d.
W ar eh ou se R d.
"B " A ve
7th St.
"H " A ve
M cN ar ne y Av e.
Mitchell Ave
Al er t R d.
Co ok
A ve
W es t D r.
"E "A ve
Extender Dr.
Sentry Rd.
34th St.
Twining Dr.
5th Ave.
Jo ne s
Globemaster Dr.
To w er R d.
Vanaman Rd.
In du st ria l B lv d.
So ut h St
1st St.
Do ol itt le
A ve
Pi cn ic R d.
Ja m es D r.
W ol fe D r.
Ai r D ep ot
Ai r D ep ot
"D " A ve
Perimeter Rd.
Rapcon Rd.
Reserve Rd
"L " A ve
Mercury Rd.
1st St.
Br ow n Dr
Po nd
R d.
O ld
A ir
De po t
Airey Dr.
General Motors Dr
Bradley Dr.
Entrance Road "C"
Entrance Road "A"
"C " A ve
"C " A ve
Vandenberg Dr.
Hi llt op R d.
Do rm ito ry
R d.
Dormitory Rd.
"M " A ve
Chennault Dr.
M itc he ll A ve
Spaatz Dr.
Co m m od ity D r.
Doolittle Ave
W hi te D r.
3rd Ave.
"D " D riv e
Ba ll
Pa rk
R d.
Joint STARS Dr.
Ai r D ep ot
B lv d
Turbine Dr. Turbine Dr.
Central Plant Dr.
6th St.6th St.
Falco n Dr.
Blackb ird
Dr.
W ey la nd
L oo p
Pegasus Dr.
Thunderbolt D r.
Munitions Rd. Ext.
Codding Rd.
Starlifter Dr.
Chidlaw Ct.
Co rs ai r D r.
Ra pt or Ct
N ig ht H aw k
Ct
Ph an to m
D r.
Fr an kl in
Po w er ho us e
Dr
Sk ym as te r D r.
Spaatz Ct.
La w re nc e
M un de ll
Nabors Dr.
In tr ud er
D r.
M cN ic kl e
M ill er D r.
Ta il
Fe at he r D r.
Holden Dr.
Ai re y C ir.
Smith Ct.
Ra ve n Ct
Air Dep ot Ai r D ep ot
Vanaman Rd.
1st St.
1st St.
TAXIWAY F
Ra w li ng s A ve
Mitc he ll A ve
Mercury Rd.
Ra ily ar d
Rd
He rc ul es
R d.
"F " A ve
Pr op ul sio n Dr
Stratofortress Dr.
96021
Arnold St.
TINKER AFB, OK
VICINITY MAP
GOTT
GATE
TINKER GATE
PASS & ID B6611
EAKER GATE
VANCE
GATE
HOPE
GATE
LEGEND
CONTRACTOR
HAUL ROUTE
TRUCK GATE
PIAZZA GATE
BASE CIVIL
ENGINEER
B400
BASE
OPERATIONS
B240
CONTRACTING
B3
HRUSKOCY
GATE
FIRE DEPARTMENT
B117
LIBERATOR GATE
LANCER
GATE
PROJECT
LOCATION
TAXIWAY A
TAXIWAY A
TAXIWAY C
So ld ie r C re ek
Soldier C reek
Soldier C reek
3220 3707
62540
62528
62523
62501X
62512
62516
62525
99999
62543
33001
62501
43609
62517
62515
62526
62527
62503
62513
62542
62501OK
62501
62502
62501
62514
62501
43610
62522
Ea st
D r.
St af f D r.
W ar eh ou se R d.
W es t D r.
Bradley Dr.
Entrance Road "C"
Entrance Road "A"
Turbine Dr. Turbine Dr.
OF
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
(SOW)
W W
YK
, W O
RE
PL
AC
E
UN
IT
S
UB
ST
AT
IO
N
SW
IT
CH
GE
AR
C
OL
V
B3
M
AR
TE
PA
-C
SA
G
S
SE
XT
O
N
MD-101
T
KI
SE
R
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
0\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
ME
CH
AN
IC
AL
DE
MO
LIT
IO
N
PL
AN
MD-101
MECHANICAL DEMOLITION PLAN
SCALE: 1/16" = 1'-0"
B3001 KEY PLAN
PROJECT LOCATION
GENERAL NOTES
1. ALL INFORMATION AND GENERAL ARRANGEMENTS SHOWN ON
DRAWINGS ARE FOR DESIGN INTENT INFORMATION ONLY.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION.
2. CONTRACTOR SHALL PROVIDE AN ADEQUATE CONSTRUCTION
BARRIER TO PROTECT ALL ADJACENT AREAS FROM DAMAGE
DURING DEMOLITION AND CONSTRUCTION.
3. CONTRACTOR SHALL STORE AND PROTECT ALL ITEMS THAT
ARE TO BE REMOVED AND RE-INSTALLED.
4. CONTRACTOR SHALL PROTECT ALL EXISTING FLOOR FINISHES,
HVAC DUCTWORK AND INSULATION, CONDUIT AND WIRING, AND
DEVICES THAT ARE TO BE MODIFIED AND/OR RE-INSTALLED.
5. SEE SOW FOR CODE AND FINISH REQUIREMENTS, MATERIAL,
EQUIPMENT AND DEVICE SPECIFICATIONS, AND ALL ADDITIONAL
INFORMATION NOT SHOWN ON THESE PLANS.
KEYED NOTES
DEMOLISH CONDENSATE TANK AND ALL PIPING BACK TO MAIN
PIPING. DEMOLISH PLATFORM TO PRIMARY STRUCTURAL
MEMBERS. GRIND SMOOTH, PREPARE STEEL FOR PAINTING
AND PAINT TO MATCH EXISTING. REFERENCE DETAILS 5 & 6 ON
SHEET M-101.
DEMOLISH CONDENSATE TANK AND ALL PIPING BACK TO MAIN
PIPING. DEMOLISH PLATFORM TO PRIMARY STRUCTURAL
MEMBERS. GRIND SMOOTH, PREPARE STEEL FOR PAINTING
AND PAINT TO MATCH EXISTING. REFERENCE DETAILS 1, 2, 3 &
4 ON SHEET M-101.
AISLEAISLEAISLE
AISLEAISLEAISLE
AI
SL
E
AI
SL
E
AI
SL
E
AI
SL
E
UP
UP
UP
UP
F135 BREAK AND
TRAINING ROOM
F/C
NDI
TA
IL
F
EA
TH
ER
S TOOL/DIE
SHEET METAL
XF
M
R
DLA/MIC SS
COMMODITIES
NAVY BOND
ROOM
B.
A.
46 47 48 49 50 52 53 54 55 5651
2'-0" EXPANSION JOINT
T
U
V
W
X X
W
V
U
T
X
W
V
U
T
X
W
V
U
T
47 49 51
47 49 51
47 49 51
47 49 51
47 49 51
X
W
V
U
T
X
W
V
U
T
46 47 48 49 50 52 53 54 55 56
T
U
V
W
X
51 51
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NEW PROPOSED
EQUIPMENT LOCATION
1 2
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
(SOW)
W W
YK
, W O
RE
PL
AC
E
UN
IT
S
UB
ST
AT
IO
N
SW
IT
CH
GE
AR
C
OL
V
B3
M
AR
TE
PA
-C
SA
G
S
SE
XT
O
N
M-101
T
KI
SE
R
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
0\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
ME
CH
AN
IC
AL
P
HO
TO
S
M-102
PHOTO - 100
SCALE: NTS
B3001 KEY PLAN
M-102
PHOTO - 101
SCALE: NTS
M-102
PHOTO - 102
SCALE: NTS
M-102
PHOTO - 103
SCALE: NTS
M-102
PHOTO - 104
SCALE: NTS
M-102
PHOTO - 105
SCALE: NTS PROJECT LOCATION
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
(SOW)
W W
YK
, W O
RE
PL
AC
E
UN
IT
S
UB
ST
AT
IO
N
SW
IT
CH
GE
AR
C
OL
V
B3
M
AR
TE
PA
-C
SA
G
D P
ER
R
Y
E-001
T
KI
SE
R
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
0\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
EL
EC
TR
IC
AL
SY
MB
OL
S
LE
GE
ND
A
ND
AB
BR
EV
IA
TI
ON
S
ELECTRICAL SYMBOLS LEGENDS AND ABBREVIATIONS
SYMBOL NOTES
1. THESE SYMBOLS APPLY TO THE ENTIRE SET OF CONTRACT DRAWINGS.
2. ALL SYMBOLS ARE NOT NECESSARILY USED IN THE DRAWINGS FOR THIS PROJECT. LISTING OF
SYMBOLS DOES NOT IMPLY THAT ALL SYMBOLS ARE USED IN THE CONTRACT DRAWINGS.
3. COLORS FOR ALL OUTLETS AND SWITCHES SHALL BE AS SHOWN ON ARCHITECTURAL PLANS.
4. ALL MOUNTING HEIGHTS SHOWN IN SYMBOL LEGEND SHALL BE AS PER TAS/ADA
REQUIREMENTS UNLESS OTHERWISE NOTED ON THE ARCHITECTURAL DRAWINGS.
5. BRANCH CIRCUIT NUMBERS MAY BE SHOWN NEXT TO SYMBOLS IN MULTIWIRE CIRCUITS.
6. EQUIPMENT IDENTIFIERS, MATCHING EQUIPMENT SCHEDULES, ARE DISPLAYED ATTACHED TO
SYMBOLS BY LEADER ARROWS, UON.
7. SYMBOL ORIENTATION DOES NOT IMPLY DEVICE OR EQUIPMENT ORIENTATION, UNLESS NOTED AS SUCH. SEE REFLECTED CEILING PLANS FOR LIGHT FIXTURE POSITIONS AND ORIENTATIONS.
8. SYMBOL SIZE DOES NOT IMPLY EQUIPMENT SIZE, UON.
9. LOWER CASE LETTER IN POSITION "X" INDICATES FIXTURES CONTROLLED BY SAME LETTER.
10. PLAN SYMBOLS USE THE FOLLOWING LINE TYPE CONVENTION AND ARE REPRESENTED AS
FOLLOWS:
LINETYPE, DENOTES EXISTING TO REMAIN
LINETYPE, DENOTES EXISTING TO BE DEMOLISHED
LINETYPE, DENOTES NEW U.G. OR CONCEALED CONSTRUCTION
LINETYPE, DENOTES NEW CONSTRUCTION
LINETYPE, DENOTES LIGHTING SWITCHLEG
A AMPERES OR TRIP
AMPERES
AC ALTERNATING CURRENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC SYMMETRICAL AMPS
INTERRUPTING CAPACITY
AWG AMERICAN WIRE GAUGE
A/R AS REQUIRED
ARR. ARRESTOR
BLDG BUILDING
BRKT BRACKET
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CL CURRENT LIMITING
CO CONDUIT ONLY
CTL CONTROL
DC DIRECT CURRENT
D.T.C. DATA TERMINAL CABINET
EMCS ENERGY MONITORING AND
CONTROL SYSTEM
FACP FIRE ALARM CONTROL
PANEL
FT FOOT, FEET
GFCI GROUND FAULT CIRCUIT
INTERRUPTER, 5MA
PERSONNEL PROTECTION
UNLESS OTHERWISE NOTED.
GRD GROUND
HZ HERTZ
IAW IN ACCORDANCE WITH
IG ISOLATED GROUND
IN INCH, INCHES
IR INFRARED
KV KILOVOLTS
KVA KILOVOLT AMPERES
KVAR KILOVOLT AMPS REACTIVE
KWH KILOWATT HOURS
L-L LINE TO LINE
L-N LINE TO NEUTRAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MTD MOUNTED
MTG MOUNTING
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL
CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS
ASSOCIATION
NEUT NEUTRAL
N.O. NORMALLY OPEN
NLT NOT LESS THAN
NMT NOT MORE THAN
OH OVERHEAD
PAS PUBLIC ADDRESS SYSTEM
PE PHOTOELECTRIC
PH PHASE
PLCS PLACES
PNL PANELBOARD
PVC POLYVINYL CHLORIDE
ELECTRICAL RACEWAY
USED ONLY U.G., CARLON
OR EQUIVALENT
RC RIGID STEEL CONDUIT
REF REFERENCE
REQ'D REQUIRED
RGC RIGID GALVANIZED STEEL
CONDUIT
RM ROOM
RMC RIGID METALIC CONDUIT
SHT SHEET
SOB STANDOFF BRACKET
SPACE SPACE(S) ONLY (NO
BREAKER DEVICE)
SPARE SPARE BREAKER OR
DEVICE
SPDT SINGLE-POLE,
DOUBLE-THROW
SPECS CONTRACT SPECIFICATIONS
SPST SINGLE-POLE,
SINGLE-THROW
S/N SOLID NEUTRAL
TB TELEPHONE BACKBOARD
TYP TYPICAL
UG UNDERGROUND
UL LISTED BY UNDERWRITER'S
LABORATORIES
UON UNLESS OTHERWISE NOTED
V VOLTS
VA VOLT AMPERES
W WATT
WH WEATHERHEAD
W/ WITH
Ø PHASE
2W+G CIRCUIT TYPE
3W+G CIRCUIT TYPE
4W+G CIRCUIT TYPE
ABBREVIATIONS
POWER SYMBOLS LEGEND
DESCRIPTIONSYMBOL
RECEPTACLE, DUPLEX, 20A, 250V, GROUNDING 2W+G, NEMA
5-20R
RECEPTACLE, DUPLEX, FLOOR MOUNTED, FLUSH, 20A, 250V,
GROUNDING 2W+G NEMA 5-20R.
RECEPTACLE, DUPLEX, CEILING MOUNTED, 20A, 250V,
GROUNDING 2W+G, NEMA 5-20R
RECEPTACLE, QUADRAPLEX
RECEPTACLE, SPECIAL PURPOSE
RECEPTACLE, CLOCK
JUNCTION BOX, ABOVE CEILING
JUNCTION BOX, WALL MOUNTED, SERVING COMPUTER LOAD.
RECEPTACLE, DUPLEX, SERVING COMPUTER LOAD. 20A, 250V,
GROUNDING 2W+G RECEPTACLE, NEMA 5-20R
SWITCH, TOGGLE, WALL MOUNTED, 20A., 120/277V RATED (AC
ONLY), SINGLE-POLE, MOUNT 48" AFF
SWITCH, TOGGLE, WALL MOUNTED, 20A., 120/277V RATED (AC
ONLY), THREE-WAY, SPDT. MOUNT 48" AFF
SWITCH, TOGGLE, WALL MOUNTED, 20A., 120/277V RATED (AC
ONLY), FOUR-WAY, SPDT. MOUNT 48" AFF
SWITCH, DIMMER, 120V, 1500 WATT. MOUNT 48" AFF
BRANCH CIRCUIT HOME RUN WITH NEUTRAL, PHASE AND
EQUIPMENT GROUND RESPECTIVELY
BRANCH CIRCUIT HOME RUN IDENTIFIER
RACEWAY, ABOVE FLOOR
COMBINATION STARTER/DISCONNECT WITH HOA
SWITCH-COORDINATE WITH MECH. CONTRACTOR.
SWITCH, DISCONNECT
PANELBOARD, SURFACE MOUNTED
PANELBOARD, RECESSED
MOTOR W/HORSEPOWER
GENERAL NOTES:
(APPLICABLE TO ALL ELECTRICAL SHEETS)
1. EQUIPMENT INTERRUPTING CAPACITIES SPECIFIED IN THE
CONTRACT DOCUMENTS ARE BASED UPON EQUIPMENT
CHARACTERISTICS AND IMPEDANCES SHOWN ON THE DRAWINGS.
IF ACTUAL INSTALLED EQUIPMENT DEVIATES FROM THESE
CHARACTERISTICS OR HAS LOWER IMPEDANCES. THE
CONTRACTOR SHALL INCREASE THE INTERRUPTING CAPACITIES
OF ALL ITEMS ON THE LOAD SIDE OF THE DEVIANT EQUIPMENT IN
DIRECT PROPORTION TO THE CHANGED CHARACTERISTICS.
INTERRUPTING CAPACITIES SHALL NOT BE REDUCED TO VALUES
LESS THAN THOSE REQUIRED BY THE CONTRACT DOCUMENTS.
2. FIRE STOP SHALL BE PROVIDED AT ALL LOCATIONS WHERE
ELECTRICAL EQUIPMENT OR SYSTEMS PENETRATE FIRE RATED
WALLS. SEE ARCHITECTURAL PLANS FOR RATED WALL
LOCATIONS.
3. CONTROL WIRING P&ID'S FOR MECHANICAL EQUIPMENT ARE NOT
SHOWN ON THESE SHEETS.
4. RISER AND ONE-LINE DIAGRAMS ARE MEANT TO SHOW
ELECTRICAL RELATIONSHIPS FOR EQUIPMENT, AND THEREFORE
MAY NOT INCLUDE ALL REQUIRED EQUIPMENT DEVICES, AND
ACCESSORIES.
DESCRIPTIONSYMBOL
TRANSFORMER, POWER, KVA RATING, WINDING VOLTAGES AND
CONNECTIONS ARE SHOWN NEXT TO SYMBOL
ONE-LINE & CONTROL SCHEMATIC LEGEND
TRANSFORMER, CURRENT, TURNS RATIO, SHOWN NEXT TO
SYMBOL
GROUNDING CONNECTION. WHEN USED WITH TRANSFORMER
WINDING SYMBOL IT INDICATES A NEUTRAL GROUNDING
CONNECTION (ON SECONDARY SIDE ONLY)
GROUNDED WYE WINDING CONNECTION
DELTA CONNECTED
RELAY OR CONTACTOR CONTACTS
SEPARABLE (PLUG-IN) CONNECTOR OR CONNECTION FOR
DRAWOUT ASSEMBLIES
SCHEMATIC, CIRCUIT CONNECTIONS
CIRCUIT BREAKER, MOLDED CASE, TRIP CURRENT [A] AND
QUANTITY OF POLES [P] SHOWN NEXT TO SYMBOL
SWITCH, DISCONNECT, NON-FUSED, LOAD BREAK. CONTINUOUS
CURRENT RATING [A] AND QUANTITY OF POLES [P] SHOWN NEXT
TO SYMBOL
SWITCH, DISCONNECT, FUSED, LOAD BREAK. FUSE AMPERE
RATING [A] AND FUSE TYPE SHOWN NEXT TO SYMBOL
FUSE, AMPERE RATING [A] AND FUSE TYPE SHOWN NEXT TO
SYMBOL
MOTOR THERMAL OVERLOAD PROTECTOR
INTEGRAL PHOTOELECTRIC CELL AND RELAY (PHOTOCONTROL)
WATTHOUR METER
CONTACTOR OR RELAY COIL. LETTER(S) INSIDE OF SYMBOL
MATCH CONTACTS CONTROLLED
SURGE ARRESTER, VALVE TYPE ARRESTER KV RATING SHOWN
NEXT TO SYMBOL
EQUIPMENT ENCLOSURE
SYMBOL MODIFIERS
DESCRIPTIONSYMBOL
AUDIBLE AND VISUALAV
EXISTINGE
FIXED TEMPERATUREF
GROUND FAULT CIRCUIT INTERRUPTERGFI
NEWN
ITEM OR DEVICE RECESSED INTO MOUNTING SURFACER
RADIO FREQUENCYRF
WEATHERPROOFWP
DEVICE MOUNTED ABOVE COUNTER TOPAC
RECEPTACLE SERVING COMPUTER LOAD.C
GROUNDING LEGEND
DESCRIPTIONSYMBOL
CONDUCTOR, BARE, UON
GROUNDING CONNECTION, COUNTERPOISE TO GROUND ROD.
B
FIRE DETECTION SYMBOLS LEGEND
DESCRIPTIONSYMBOL
FIRE ALARM CONTROL PANEL
FIRE ALARM MANUAL PULL STATION
REMOTE ANNUNCIATOR PANEL
FIRE ALARM SIGNALING DEVICE, VISUAL ONLY
FIRE ALARM SIGNALING DEVICE, AUDIO/VISUAL, HORN AND
LIGHT (1 ASSEMBLY)
FIRE ALARM TRANSMITTER
FIRE HEAT DETECTOR, W/ TEMPERATURE OR RATE OF RISE.
SMOKE DETECTOR
SPRINKLER SYSTEM VALVE TAMPER SWITCH
SPRINKLER SYSTEM FLOW SWITCH
FIREMANS TELEPHONE
ELEVATOR RECALL
SCHEMATIC CIRCUIT
ELECTRICAL BUSS
CABLE OR WIRE
D
WYE CONNECTEDY
LIGHTING SYMBOLS LEGEND
SURFACE RECEPTACLE STRIP
RACEWAY, RISER UP
RACEWAY, RISER DOWN
THERMOSTAT BY MECHANICAL CONTRACTORT
POWER SYMBOLS LEGEND (CONTINUED)
DESCRIPTIONSYMBOL
RECEPTACLE, DUPLEX, SPECIAL PURPOSE
TELEPHONE RECEPTACLE, WALL MOUNTED
BELL
SPEAKER, CEILING MOUNTED
MICROPHONE, CEILING MOUNTED
SPEAKER CONTROL
SOUND CABINET
AUDIO/VISUAL PROJECTOR
CEILING FAN
CABLE TV OUTLET
EXHAUST FAN
SWITCH, OCCUPANCY SENSOR
WIREMOLD
240 VOLT 20 AMP RECEPTACLE
WATER PROOFWP
SWITCH, TOGGLE, WALL MOUNTED, 20A., 120/277V RATED (AC
ONLY), DOUBLE-POLE, MOUNT 48" AFF
SWITCH, PULL SWITCH, CEILING MOUNTED
DESCRIPTIONSYMBOL
FLUORESCENT/LED, SURFACE OR PENDANT, RECESSED CEILING
MOUNTED
FLUORESCENT/LED, WALL MOUNTED
NIGHT LIGHT, FLUORESCENT/LED FIXTURE WITH INTERGAL
EMERGENCY BALLAST
CFL/HID/LED FIXTURE, RECESSED CEILING MOUNTED
CFL/HID/LED FIXTURE, WALL MOUNTED
EXIT SIGN, LIGHTED, SURFACE OR PENDANT, CEILING MOUNTED
W/LIGHTED FACE AND DIRECTIONAL ARROW.
EXIT SIGN, LIGHTED, WALL MOUNTED.
EMERGENCY LIGHT, 2 LAMPS, BATTERY POWERED
BRANCH CIRCUIT HOME RUN
CFL/HID/LED FIXTURE, SURFACE OR PENDANT
FIRE ALARM SIGNALING DEVICE, BELL
TRANSFORMER, DRY TYPE
NIGHT LIGHTNL
DATA RECEPTACLE, WALL MOUNTED
TELEPHONE/DATA RECEPTACLE, WALL MOUNTED
SURGE PROTECTION DEVICE
GROUND FAULT PROTECTION
VARIABLE FREQUENCY DRIVER
C
F
C
J
C J
W
S
S2
S3
S4
SDM
S
EL-5
T
M 1/20HP
S
M
TV
M
VFD
3P 1200A
M
C
SPD
GFP
FCP
F
FSA
FTR
135°
ESR
SYSTEM FURNITURE POINT IN WALL
FLOOR BOX WITH RECEPTACLE AND DATA OUTLET
SOS
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
(SOW)
W W
YK
, W O
RE
PL
AC
E
UN
IT
S
UB
ST
AT
IO
N
SW
IT
CH
GE
AR
C
OL
V
B3
M
AR
TE
PA
-C
SA
G
D P
ER
R
Y
ED-101
T
KI
SE
R
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
0\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
EL
EC
TR
IC
AL
DE
MO
LIT
IO
N
PL
AN
ED101
ELECTRICAL DEMOLITION PLAN
SCALE: 1/16" = 1'-0"
B3001 KEY PLAN
GENERAL NOTES
1. ALL INFORMATION AND GENERAL ARRANGEMENTS SHOWN ON
DRAWINGS ARE FOR DESIGN INTENT INFORMATION ONLY.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION.
2. CONTRACTOR SHALL PROVIDE AN ADEQUATE CONSTRUCTION
BARRIER TO PROTECT ALL ADJACENT AREAS FROM DAMAGE
DURING DEMOLITION AND CONSTRUCTION.
3. CONTRACTOR SHALL STORE AND PROTECT ALL ITEMS THAT
ARE TO BE REMOVED AND RE-INSTALLED.
4. CONTRACTOR SHALL PROTECT ALL EXISTING FLOOR FINISHES,
HVAC DUCTWORK AND INSULATION, CONDUIT AND WIRING, AND
DEVICES THAT ARE TO BE MODIFIED AND/OR RE-INSTALLED.
5. SEE SOW FOR CODE AND FINISH REQUIREMENTS, MATERIAL,
EQUIPMENT AND DEVICE SPECIFICATIONS, AND ALL ADDITIONAL
INFORMATION NOT SHOWN ON THESE PLANS.
PROJECT LOCATION
KEYED NOTES
12470V PRIMARY LOAD SWITCH TO BE REPLACED.
1000kVA TRANSFORMER TO BE REPLACED.
480/277V SWITCHBOARD TO BE REPLACED.
AISLEAISLEAISLE
AISLEAISLEAISLE
AI
SL
E
AI
SL
E
AI
SL
E
AI
SL
E
UP
UP
UP
UP
F135 BREAK AND
TRAINING ROOM
F/C
NDI
TA
IL
F
EA
TH
ER
S TOOL/DIE
SHEET METAL
XF
M
R
DLA/MIC SS
COMMODITIES
NAVY BOND
ROOM
B.
A.
46 47 48 49 50 52 53 54 55 5651
2'-0" EXPANSION JOINT
T
U
V
W
X X
W
V
U
T
X
W
V
U
T
X
W
V
U
T
47 49 51
47 49 51
47 49 51
47 49 51
47 49 51
X
W
V
U
T
X
W
V
U
T
46 47 48 49 50 52 53 54 55 56
T
U
V
W
X
51 51
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NEW PROPOSED
EQUIPMENT LOCATION
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
(SOW)
W W
YK
, W O
RE
PL
AC
E
UN
IT
S
UB
ST
AT
IO
N
SW
IT
CH
GE
AR
C
OL
V
B3
M
AR
TE
PA
-C
SA
G
D P
ER
R
Y
E-101
T
KI
SE
R
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
0\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
EL
EC
TR
IC
AL
P
LA
N
E101
PLATFORM "V51" EQUIPMENT LAYOUT
SCALE: 1/16" = 1'-0"
B3001 KEY PLAN
GENERAL NOTES
1. ALL INFORMATION AND GENERAL ARRANGEMENTS SHOWN ON
DRAWINGS ARE FOR DESIGN INTENT INFORMATION ONLY.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION.
2. CONTRACTOR SHALL PROVIDE AN ADEQUATE CONSTRUCTION
BARRIER TO PROTECT ALL ADJACENT AREAS FROM DAMAGE
DURING DEMOLITION AND CONSTRUCTION.
3. CONTRACTOR SHALL STORE AND PROTECT ALL ITEMS THAT
ARE TO BE REMOVED AND RE-INSTALLED.
4. CONTRACTOR SHALL PROTECT ALL EXISTING FLOOR FINISHES,
HVAC DUCTWORK AND INSULATION, CONDUIT AND WIRING, AND
DEVICES THAT ARE TO BE MODIFIED AND/OR RE-INSTALLED.
5. SEE SOW FOR CODE AND FINISH REQUIREMENTS, MATERIAL,
EQUIPMENT AND DEVICE SPECIFICATIONS, AND ALL ADDITIONAL
INFORMATION NOT SHOWN ON THESE PLANS.
PROJECT LOCATION
KEYED NOTES
NEW 12470V PRIMARY LOAD SWITCH.
NEW 1000kVA TRANSFORMER.
NEW 480/277V SWITCHBOARD.
CAGE LADDER TO BE INSTALLED. COORDINATE WITH USER ON
FINAL LOCATION.
REMOTE CONTROL PANEL.
12470V
1000/1333kVA 12470-480/277V
1600AF
1600AT
1600AF
1200AT
1600AF
1200AT12
5E
METERS
SPACE
N.O.
9#500MCM, 3#2/0, #2GND
"NORTH BUS"
PLUG-IN BUSWAY
1200A, 480/277V
TIE TO
PLATFORM "V91-1"
"SOUTH BUS"
PLUG-IN BUSWAY
1200A, 480/277V
TIE TO
PLATFORM "V51"
CABLE
TAP BOX
CABLE
TAP BOX
TO P53
E101
PLATFORM "V51" SINGLE LINE DIAGRAM
SCALE: N.T.S.
AISLEAISLEAISLE
AISLEAISLEAISLE
AI
SL
E
AI
SL
E
AI
SL
E
AI
SL
E
UP
UP
UP
UP
F135 BREAK AND
TRAINING ROOM
F/C
NDI
TA
IL
F
EA
TH
ER
S TOOL/DIE
SHEET METAL
XF
M
R
DLA/MIC SS
COMMODITIES
NAVY BOND
ROOM
B.
A.
46 47 48 49 50 52 53 54 55 5651
2'-0" EXPANSION JOINT
T
U
V
W
X X
W
V
U
T
X
W
V
U
T
X
W
V
U
T
47 49 51
47 49 51
47 49 51
47 49 51
47 49 51
X
W
V
U
T
X
W
V
U
T
46 47 48 49 50 52 53 54 55 56
T
U
V
W
X
51 51
NIC
NIC
NIC
NIC
NIC
NIC
NIC
8'-51 2" 8'-51
2"
16'-11"
3'-0" 3'-0"
6'-0"5'-51 2" 5'-51
2"
1'- 8"
7'- 6"
5'- 6"
3@ 1'-
9'- 2"
'-8
4'-
51 2" 4'-
51 2"
'-7
EXISTING EQUIPMENT PLATFORM
PROPOSED NEW SWITCHGEAR
AND TRANSFORMER
PROPOSED LADDER AND PLATFORM
PROPOSED REMOTE CONTROL PANEL
EXISTING LADDER
| 01-140020-G101-G101 |
| Sheets and Views |
| G101 |
| 02-140020-MD101-MD101 |
| Sheets and Views |
| MD101 |
| 03-140020-M101-M101 |
| Sheets and Views |
| M101 |
| 04-140020-E001-E001 |
| Sheets and Views |
| E001 |
| Plot View |
| 05-140020-ED101-ED101 |
| Sheets and Views |
| ED101 |
| 06-140020-E101-E101 |
| Sheets and Views |
| E101 |
File details come from the government source that posted it. Updated .