APPENDIX C 11-87 Cooling Tower.docx

DOCX document 30 KB Posted

Attached to
Cooling Towers Repair Federal contract opportunity
Solicitation number
FA8125-11-Q-0063
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Tinker Air Force Base

About this file

Appendix C (Safety)

View the file

Other files for this federal contract opportunity

Other files attached to Cooling Towers Repair, newest first.
File Type Posted
Appendix A-3 Cooling Tower.docx DOCX document
Appendix A-2 Cooling Tower.docx DOCX document
Appendix A Cooling Tower.docx DOCX document
Combined Solicitation.doc DOC document
Appendix A-4 Cooling Tower.docx DOCX document
Appendix B.pdf PDF
Appendix A-1 Cooling Tower.docx DOCX document
Appendix A-5 Cooling Tower.docx DOCX document
Wage Determination 3 Nov 10.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

25 May 2011

APPENDIX "C"

FOR

HEAT TREAT SOUTH ANNEX

COOLING WATER SYSTEM REPAIR

PRE FILE NO: 76 MXW/SEG 11-87

PREPARED BY: 76 MXW/SEG

SECTION I - GENERAL REQUIREMENTS

A. Safety Program Requirements. The contractor will implement a safety program that ensures protection of Government personnel and property. The program will consist of, as a minimum:

1. Mishap notification/reporting as defined in paragraph B. below.

2. A Safety Program that addresses, as a minimum, the subjects listed in Safety Program Elements, Section II and to be used during performance of the work described in the contract.

B. Mishap Notification.

1. The contractor shall notify the procuring Safety Office or a designated Government Representative (GR) within one (1) hour of all mishaps or incidents. A written report of the mishap/incident shall be sent within three calendar days to the GR, who will forward it to the Procuring Safety Office. For information not available at the time of initial written report, the contractor shall provide the remaining information no later than 20 calendar days after the mishap, unless extended by the Safety Office.

2. Mishap notifications shall contain, as a minimum, the following information:

a.Contract, Contract Number, Name and Title of Person(s) Reporting
b.Date, Time and exact location of accident/incident
c.Brief Narrative of accident/incident (Events leading to accident/incident)
d.Cause of accident/incident, if known
e.Estimated cost of accident/incident (material and labor to repair/replace)
f.Nomenclature of equipment and personnel involved in accident/incident
g.Corrective actions (taken or proposed)
h.Other pertinent information

3. If requested by the designated government representative, the contractor shall immediately secure the mishap scene/damaged property and impound pertinent maintenance and training records, until released by the Procuring Safety Office.

C. The safety provisions of this contract, shall apply to any subcontracts/subcontractors.

1. Safety requirements listed herein that do not concern contractor’s operations or services shall be considered self-deleting as mutually agreed by the contractor and the procuring office.

SECTION II - SAFETY PROGRAM ELEMENTS

The contractor’s Safety Program shall clearly define procedures, personnel qualifications, facilities and required equipment necessary to fulfill the following elements:

Element/Requirement Referenced Benchmark

OSHA Standards for Construction 29 CFR 1926

Cranes and Derricks in Construction 29 CFR 1926 Subpart CC

Fall Protection 29 CFR 19126 Subpart M

Control of Hazardous Energy 29 CFR 1910.147

Permit Required Confined Space 29 CFR 1910.146

Confined Space Program AFOSH Std 91-25

76 MXW Confined Space Program MXWOI 91-25

Housekeeping AFOSH Std. 91-501

Material Handling Equipment (MHE) AFOSH Std. 91-46 and AFOSH Std.91-501

Handling, Storage and use of AFOSH Std. 91-501 Flammable/Combustible Liquid

Vehicle Operations AFI 91-207

Tool Control AFI 21-101, AFMC Sup.

Foreign Object Damage (FOD) AFI 21-101, AFMC Sup

Tobacco Use in the Air Force AFI 40-102

Hazardous Energy Control AFOSH Std. 91-501

Fire Protection Tinker Instruction 32-2001

Control of Hazardous Energy Tinker Instruction 91-310

SECTION III - BIBLIOGRAPHY OF PUBLICATIONS/DIRECTIVES

These publications/directives and all supplements/changes thereto apply to the extent required by the provisions of Sections I, and II.

AFI 91-204 Feb 06 Safety Investigations and Reports

AFI 91-207 May 07 USAF Traffic Safety Program

AFOSH Std. 91-66 Oct 97 General Industrial Operations

AFOSH Std. 91-501 Jul 04 Air Force Consolidated Occupational Safety Standard

AFOSH Std. 91-100 May 98 Aircraft Flight Line – Ground Operations and Activities

AFI 21-101 Jun 06 Aircraft and Equipment Maintenance Management

AFI 21-101, Dec 07 Aircraft and Equipment Maintenance Management AFMC Sup

AFI 40-102 Jun 02 Tobacco Use in the Air Force

AFOSH Std 91-25 Feb 98 Confined Spaces

AFOSH Std 91-5 May 97 Welding, Cutting, and Blazing

Tinker Instruction 32-2001 Sept 97 Fire Protection Program

29 CFR 1910 OSHA Standards for General Industry

29 CFR 1926 OSHA Standards For The Construction Industry

Tinker Instruction May 08 Control of Hazardous Energy 91-310

Tinker Instruction Oct 10 Confined Space Entry Program 91-25