FA520523R00040001_Atch3_Revised Drawing Sheets_13Jun23.pdf
PDF 2 MB Posted
- Attached to
- Project No. QKKA214009, Repair JNCO Homes, MFH, 123, 125, 127, 129, 291, Misawa Air Base, Japan
- Solicitation number
- FA520523R0004
About this file
This document package includes construction drawings and specifications for repair work on five military family housing units at Misawa Air Base in Japan. The drawings show renovation plans for the units including updated floor plans, structural details, and electrical and EMCS systems. Specifications require installing new porch canopies, foundations, and interior renovations. The project also involves upgrading EMCS control panels and wiring to integrate building automation. Fiber optic and twisted pair cabling will connect the panels to a central controller and building systems. The solicitation seeks bids from qualified contractors to complete the repair and renovation work according to the drawings and specifications by the required completion date. The federal agency issuing this RFP is the Department of the Air Force Pacific Air Forces for Project No. QKKA214009.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T T
T T
T T
T T
BEDRM 1
BATH
LIVING CLO
TERRACE
STAIR
RM
BATH
CLO
LIVING
REF
DW
W
D
SK
REF
CLO
RAN
SK
LAUNDRY LAUNDRY
HALL
BEDRM 2
CLO
ENTRY/PORCH
CLO
TERRACE
BEDRM 1
BEDRM 2
CLO
RAN
DW
W
D
DINING/KITDINING/KIT
HALL
STAIR
TRASHTRASH
STOR
STOR
STOR
STOR
CLO CLOLN
CLOCLO
LN
ACCESS
PANEL (E)
FIRE RISER
ENCLOSURE
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
PA
N
TH
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
SCALE: 1:50
0 500 20001000 3000mm
GRAPHIC SCALE:1 TYPICAL RENOVATED FIRST FLOOR PLAN*
RENOVATION KEY NOTES:
N01
N02
N03
N04
N05
N06
N07
N08
N09
N10
N12
N13
N14
N15
N16
N01
N04
N05
N06
N08
N17
N12
N18
N18
N18
LEGEND
N19
N19
N20
N18
N18
N39
N39
N40
N40
UNIT A UNIT B
N33
A-101
TY
PI
C
AL
R
EN
O
VA
TE
D
F
IR
ST
F
LO
O
R P
LA
N
NX
N15
N02
N03 N03
N03
N03 N03
N05 N08
N13
N13
N13
N13
N13
N17
N17
N16
N20
N33 N33
N33
N33
N33
N33
N33
N33
N33
N33
N02
N33 N13
N01
N03 N13
N17
N33
N33
N33
N02
N03
N03
N13
N13
N13
N16
N20
N33 N33
N33
N33
N02
N33
N03 N13
N17
N33
N33
N33
N03
N13
N36
N36
N09
Attachment 3 to FA520523R00040001
A1
D1
A
C
C1
B1
B
D
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
1 STAIR RM FIRST FLR PLAN
RENOVATION KEY NOTES:
TYPICAL ENLARGED
N32
N14
N12
N10
N10
N05 N05 N12
STAIR ROOM
N14
STAIR
N19
N14 N32
SCALE: 1:25
0 500 1000
GRAPHIC SCALE:
1500mm
N33
N54
N54
N12 N12
N12N12
N19
N19
STAIR ROOM INTERIOR ELEVATIONS
N33
A-407
TY
PI
C
AL
E N
LA
R
G
ED
S
TA
IR
R
O O
M F
IR
ST
F
LO
O R
P
LA
N A
N D
IN
TE
R
IO
R E
LE
VA
TI
O
N S
N15
N15
SC1 SC1
C1 C1C
SG
SG
C
SG
SG
SB1
SG1
SB
SB
SB1
F1 F1
PO
RC
H
CA
NO
PY
F
RA
MI
NG
P
LA
N
AN
D
EL
EV
AT
IO
N
FO
R
ST
EE
L W
OR
KS
PORCH CANOPY FRAMING PLAN1 PORCH CANOPY FOUNDATION PLAN2
PORCH CANOPY FRAMING ELEVATION 3
GRAVEL LEVEL
BOTTOM OF FOOTING
*1
FIRST FLOOR
SECOND FLOOR
CSG1SG1
C1
SC1
C1
SC1
F1
C1
SC1
F1
RIDGE OF FRONT PORCH CANOPY
BOTTOM OF BEAM
SG1 SG1
SB5
F1
0 5000 1500 2500 5000 0 5000 1500 2500 5000
0 5000 1500 2500 5000
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
STRUCTURAL
THIS WORK WAS PREPARED BY ME
OR UNDER MY SUPERVISION
(NAME AND LICENSE)
PROJECT ENGINEER
一級建築士
(1st Class Kenchikushi)
LC# 166690
EXPIRATION DATE : NONE
TAKASHI HATTORI
SIGNED
S-103
GRAVEL LEVEL
BOTTOM OF FOOTING
FIRST FLOOR
SECOND FLOOR
C1
SC1
C1
SC1
F1
C1
SC1
F1
RIDGE OF FRONT PORCH CANOPY
BOTTOM OF BEAM
F1
B125,B127,B129 FRAMING ELEVATION3 FR
AM
IN
G
PL
AN
A
ND
S
EC
TI
ON
F
OR
C
ON
CR
ET
E
FO
UN
DA
TI
ON
GRAVEL LEVEL
BOTTOM OF FOOTING
FIRST FLOOR
SECOND FLOOR
SC1 SC1 SC1
RIDGE OF FRONT PORCH CANOPY
BOTTOM OF BEAM
GRAVEL LEVEL
BOTTOM OF FOOTING
*1
FIRST FLOOR
SECOND FLOOR
C1
SC1
C1
SC1
C1
SC1
RIDGE OF FRONT PORCH CANOPY
BOTTOM OF BEAM
F1 F1
C1
F1
C1C1
B123 FRAMING ELEVATION 1 B291 FRAMING ELEVATION2
DETAIL C1/F14
C1
F1
F1 F1 F1
*1 FROST PENETRATION:MORE THAN 762mm (30'').
*1
*1
*1 FROST PENETRATION:MORE THAN 762mm (30'').
*1 FROST PENETRATION:MORE THAN 762mm (30'').
0 5000 1500 2500 50000 5000 1500 2500 5000
0 5000 1500 2500 5000
0 500 1500 2500
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
STRUCTURAL
THIS WORK WAS PREPARED BY ME
OR UNDER MY SUPERVISION
(NAME AND LICENSE)
PROJECT ENGINEER
一級建築士
(1st Class Kenchikushi)
LC# 166690
EXPIRATION DATE : NONE
TAKASHI HATTORI
SIGNED
S-105
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
PA
EDA
Y
AS
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A ,II
AH
W U
UL K. U
PA
EDA
Y
AS
LICENSED
PROFESSIONAL
ENGINEER
No. 7646-E
A ,II
AH
W U
UL K. U
FIBER CABLE
SPLICE BOX
CENTRAL CONTROLLER
(EW-50J)
SPD
BREAKER
BREAKER
POWER SUPPLY
ETHERNET MEDIA
CONVERTER
SPD FOR RS-485
ECLYPSE
24V POWER SUPPLY
ECLYPSE
DDC CONTROLLER
ECLYPSE
16 DIGITAL INPUT
MODULE
GROUND BUS
GROUND LUG
VENT DRAIN
EMCS CABINET
PLYWOOD MOUNTING
SURFACE
24P TERMINAL
BLOCKS
PVC WIREWAY
12 STRAND FIBER
CABLE IN 65MM
CONDUIT
(3)3.5MM^2 CABLE
IN 28MM CONDUIT
1 PAIR SHIELDED
0.5MM^2 IN 28MM
CONDUIT
1 PAIR SHIELDED
1.25MM^2 IN 28MM
CONDUIT
38MM^2 IN 28MM
CONDUIT
TO HANDHOLE
TO ELECTRICAL PANEL BOARD
(PANEL M-H)
TO WATER METERS X4
SPD FOR RS-485
DC500mA
485-S
485+S
S M
F
I B
E R
FIBER CABLE SPLICE BOX
B
E R
TO PANEL M-H
POWER CABLE
TO PUMP HOUSE
12 STRAND FIBER CABLE
TO
POWER METER
(PANEL M-H)
MODBUS CABLE
TO
HEAT PUMP
M-NET CABLE
24P TERMINAL
A C
R
A C
S
E E
485-S
485+S
485-S
485+S
485-S
485+S
E
24V
AC/DC
24V
COM
P
N
24V POWER
SUPPLY
A C
R
A C
S
E
E
E
AC120R
AC120S
E
E
E
+ - S
RS-485
ETHERNET
SWITCH
PRI SEC
DDC CONTROLLER
ECLYPSE CONNECTED SYSTEM CONTROLLER
16 DIGITAL INPUT MODULE
UNIVERSAL INPUTS
UI1 COM UI2 UI3 COM UI4 18VDC
SUBNET DEVICE HOST
COM
UO1 UO2 UO3 UO4
UNIVERSAL OUTPUTS
A
B
C
D
E
F
N24
P24
N24
P24
R1 S1
R2 S2
R1
S1
R1
S1
R1 S1
L N
V- V+
POWER
SUPPLY
DC24V
SPD
AC100-200V
10A 10KA
E
1/L1 3/L2
BREAKER BREAKER
ETHERNET MEDIA CONVERTER
V1,V2 INPUTS 12-45VDC
PWR1
FAULT
PWR2
P24
TX
RX
LAN
N24
PRI
R2
S2
R2 S2
TB1(AC)
100/200V
TB3(M-NET)
A B S
LAN 1
LAN 2
SEC
(EW-50J)
AC100/200V 50/60HZ 12W
PRI
SEC
LAN
AC100R
AC100S
E
SM FIBER
SM FIBER
TYPICAL EMCS CONTROL WIRE INTERCONNECTION
AC120S
AC120S
AC120R
AC120R
7 23
15 GFCI RECEPTACLE
5-20R
7 23
A B S R S E + - S
L A
N
BUILDING 123 & 291 EMCS CABINET1
SHEET NOTES:
NEW EMCS ENCLOSURE. PROVIDE IP
700MM WIDE X 1,200MM HIGH X 200MM DEEP MINIMUM WITH WOOD
BACK BOARD. (PANASONIC BPS711220V WITH LOCK AND KEY. LOCK
TYPE SHALL BE TAKIGEN TAK70) PROVIDE ON INSIDE DOOR OF
CABINET PROVIDE LAMINATED LINE DIAGRAM OF INTERIOR WIRING
AND CONDUITS OF CABINET.
NOT USED.
PROVIDE MEDIA CONVERTER WITH POWER SUPPLY.
PROVIDE TWISTED PAIR PATCH CABLE BETWEEN
MEDIA CONVERTER, EC-BOS AND ECLIPSE CONTROLLER.
PROVIDE 2 STRAND SM FIBER OPTIC PATCH CABLE BETWEEN FIBER
PATCH PANEL AND MEDIA CONVERTER.
CENTRAL CONTROLLER. PROVIDE WITH INDIVIDUAL POWER SUPPLY
65MM SQUARE PVC WIREWAY MINIMUM.
FIBER PREMISES CONNECTOR CABINET (SBX-T2027E-C2-SC12-K12)
12 STRAND SC CONNECTOR TYPE.
12 STRAND FIBER CABLE FROM PUMP HOUSE.
CONDUIT FROM HAND HOLE (SEE EMCS SITE DRAWINGS).
CONDUIT SHALL CONTAIN 12-STRAND SINGLE MODE FIBER
WHICH IS TO TERMINATE IN DEMARCATION BOX (SEE NOTE 7).
PROVIDE 1 PAIR SHIELDED 1.25MM^2 CABLE TO HEAT PUMPS.
PROVIDE NEW 28MM RIGID STEEL CONDUIT BETWEEN NEW EMCS
ENCLOSURE AND JUNCTION BOX.
PROVIDE NEW POWER SUPPLY DC24V.
NEW 28MM RIGID STEEL CONDUIT FOR GROUNDING CONDUCTOR
FROM ENCLOSURE TO EXTERNAL GROUNDING SYSTEM.
PROVIDE NEW 38MM^2 STRANDED COPPER GROUNDING
CONDUCTOR BETWEEN GROUND BUS AND EXTERNAL
GROUNDING SYSTEM. BOND CONDUIT TO GROUNDING
CONDUCTOR.
DEDICATED 120V, 20A CIRCUIT FROM NEW/REPLACED PANEL M-H.
PROVIDE (2) 3.5MM^2 & (1) 3.5MM^2 GROUND IN 28MM RIGID STEEL
CONDUIT.
PROVIDE TWO 125V, 20A, NEMA5-20R, WEATHER RESISTANT,
GFCI RECEPTACLE, SURFACE MOUNTED INSIDE ENCLOSURE.
NEW GROUND BUS BONDED TO ENCLOSURE. 10 OHMS OR LESS MUST
NEW 24 SPACE TERMINAL STRIP. NUMBER ALL SPACES 1-24.
LABEL ALL WIRING ENTERING ENCLOSURE WITH REVERSE
NUMBERING METHOD. PROVIDE TERMINAL WIRE JACKET.
VENT DRAIN - STAINLESS STEEL (HOFFMANN H2OMIT).
ECLIPSE CONTROLLER WITH ECY-16DI AND ECY PC-24 POWER SUPPLY.
PROVIDE BOND BUSHING FITTING TO BOND ENCLOSURE AND
EXTERNAL GROUNDING SYSTEM.
CAT-6 PATCH CABLE
ELECTRIC METER CABLE
FIBER OPTIC PATCH PANEL - 12 STRAND SC SINGLE MODE PATCH PANEL.
BREAKER FOR ECLIPSE / MEDIA CONVERTER.
BREAKER FOR CENTRALIZED CONTROLLER (EW-50J).
SURGE PROTECTIVE DEVICE FOR ECLIPSE / MEDIA CONVERTER /
CENTRALIZED CONTROLLER (EW-50J).
SURGE PROTECTIVE DEVICE FOR MODBUS.
STRUT CONDUIT SUPPORT
29 LISTED RIGID STEEL CONDUIT TO UNDERGROUND FEP CONDUIT
COUPLING
AND BREAKER.
TO ELECTRICAL PANEL BOARD
(PANEL M-H : POWER METER)
TO HEAT PUMP UNITS
SEE ELECTRICAL FOR
TWISTED PAIR
CABLE IN 28MM
CONDUIT
30 PROVIDE TWISTED PAIR CABLE TO WATER METERS.
GENERAL NOTES:
1. WIRE/CABLE MANAGEMENT: INCLUDE LABELING FOR ALL
WIRES FROM DEVICE TO ITS TERMINATION LOCATION.
INCLUDE IN SHOP DRAWINGS PROVIDED TO THE
INSTALLATION FOR APPROVAL.
2. POWER AND GROUND WIRE COLORING CODES SHOULD MATCH
REQUIREMENT BY NEC.
BE PRESENT FOR GROUNDING OF THE EMCS PANEL. IF TESTED AND HIGHER
THAN 10 OHMS ADDITIONAL GROUNDING IS REQUIRED.
TO EC-BOS POWER
SUPPLY IN EMCS
CABINET CLOSEST TO
PUMP HOUSE ONLY
33 FUSED POWER
DISTRIBUTION
BLOCK
31 PANEL MOUNTED FUSED POWER DISTRIBUTION BLOCK
EC-BOS IN EMCS CABINET LOCATED AT THE BUILDING 32
CLOSEST TO THE PUMP HOUSE (BUILDINGS 123 & 291 ONLY).
EC-BOS32
BREAKER
POWER SUPPLY12
33 BREAKER FOR EC-BOS.
EC-BOS
SPD
34 SURGE PROTECTIVE DEVICE FOR EC-BOS
L A
N
GROUNDING SYSTEM
FINISHED GRADE
66 STAINLESS STEEL CABINET
IP66 STAINLESS STEEL
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
EM503
E M
C
D
E T
A I L
FIBER CABLE
SPLICE BOX
CENTRAL CONTROLLER
(EW-50J)
SPD
BREAKER
BREAKER
POWER SUPPLY
ETHERNET MEDIA
CONVERTER
SPD FOR RS-485
ECLYPSE
24V POWER SUPPLY
ECLYPSE
DDC CONTROLLER
ECLYPSE
16 DIGITAL INPUT
MODULE
GROUND BUS
GROUND LUG
VENT DRAIN
EMCS CABINET
PLYWOOD MOUNTING
SURFACE
24P TERMINAL
BLOCKS
PVC WIREWAY
12 STRAND FIBER
CABLE IN 65MM
CONDUIT
(3)3.5MM^2 CABLE
IN 28MM CONDUIT
1 PAIR SHIELDED
0.5MM^2 IN 28MM
CONDUIT
1 PAIR SHIELDED
1.25MM^2 IN 28MM
CONDUIT
38MM^2 IN 28MM
CONDUIT
TO HANDHOLE
TO ELECTRICAL PANEL BOARD
(PANEL M-H)
TO WATER METERS X4
SPD FOR RS-485
DC500mA
485-S
485+S
B
E R
FIBER CABLE SPLICE BOX
B
E R
TO PANEL M-H
POWER CABLE
TO PUMP HOUSE
12 STRAND FIBER CABLE
TO
POWER METER
(PANEL M-H)
MODBUS CABLE
TO
HEAT PUMP
M-NET CABLE
24P TERMINAL
A C
R
A C
S
E E
485-S
485+S
485-S
485+S
485-S
485+S
E
24V
AC/DC
24V
COM
P
N
24V POWER
SUPPLY
A C
R
A C
S
E
E
E
AC120R
AC120S
E
E
E
+ - S
RS-485
ETHERNET
SWITCH
PRI SEC
DDC CONTROLLER
ECLYPSE CONNECTED SYSTEM CONTROLLER
16 DIGITAL INPUT MODULE
UNIVERSAL INPUTS
UI1 COM UI2 UI3 COM UI4 18VDC
SUBNET DEVICE HOST
COM
UO1 UO2 UO3 UO4
UNIVERSAL OUTPUTS
A
B
C
D
E
F
N24
P24
N24
P24
R1 S1
R2 S2
R1
S1
R1
S1
R1 S1
L N
V- V+
POWER
SUPPLY
DC24V
SPD
AC100-200V
10A 10KA
E
1/L1 3/L2
BREAKER BREAKER
ETHERNET MEDIA CONVERTER
V1,V2 INPUTS 12-45VDC
PWR1
FAULT
PWR2
P24
TX
RX
LAN
N24
PRI
R2
S2
R2 S2
TB1(AC)
100/200V
TB3(M-NET)
A B S
LAN 1
LAN 2
SEC
(EW-50J)
AC100/200V 50/60HZ 12W
PRI
SEC
LAN
AC100R
AC100S
E
SM FIBER
SM FIBER
TYPICAL EMCS CONTROL WIRE INTERCONNECTION
AC120S
AC120S
AC120R
AC120R
7 23
15 GFCI RECEPTACLE
5-20R
7 23
A B S R S E + - S
L A
N
BUILDING 125, 127 & 129 EMCS CABINET1
SHEET NOTES:
700MM WIDE X 1,200MM HIGH X 200MM DEEP MINIMUM WITH WOOD
BACK BOARD. (PANASONIC BPS711220V WITH LOCK AND KEY. LOCK
TYPE SHALL BE TAKIGEN TAK70) PROVIDE ON INSIDE DOOR OF
CABINET PROVIDE LAMINATED LINE DIAGRAM OF INTERIOR WIRING
AND CONDUITS OF CABINET.
NOT USED.
PROVIDE MEDIA CONVERTER WITH POWER SUPPLY.
PROVIDE TWISTED PAIR PATCH CABLE BETWEEN
MEDIA CONVERTER AND ECLIPSE CONTROLLER.
PROVIDE 2 STRAND SM FIBER OPTIC PATCH CABLE BETWEEN FIBER
PATCH PANEL AND MEDIA CONVERTER.
CENTRAL CONTROLLER. PROVIDE WITH INDIVIDUAL POWER SUPPLY
65MM SQUARE PVC WIREWAY MINIMUM.
FIBER PREMISES CONNECTOR CABINET (SBX-T2027E-C2-SC12-K12)
12 STRAND SC CONNECTOR TYPE.
12 STRAND FIBER CABLE FROM PUMP HOUSE.
CONDUIT FROM HAND HOLE (SEE EMCS SITE DRAWINGS).
CONDUIT SHALL CONTAIN 12-STRAND SINGLE MODE FIBER
WHICH IS TO TERMINATE IN DEMARCATION BOX (SEE NOTE 7).
PROVIDE 1 PAIR SHIELDED 1.25MM^2 CABLE TO HEAT PUMPS.
PROVIDE NEW 28MM RIGID STEEL CONDUIT BETWEEN NEW EMCS
ENCLOSURE AND JUNCTION BOX.
PROVIDE NEW POWER SUPPLY DC24V.
NEW 28MM RIGID STEEL CONDUIT FOR GROUNDING CONDUCTOR
FROM ENCLOSURE TO EXTERNAL GROUNDING SYSTEM.
PROVIDE NEW 38MM^2 STRANDED COPPER GROUNDING
CONDUCTOR BETWEEN GROUND BUS AND EXTERNAL
GROUNDING SYSTEM. BOND CONDUIT TO GROUNDING
CONDUCTOR.
DEDICATED 120V, 20A CIRCUIT FROM NEW/REPLACED PANEL M-H.
PROVIDE (2) 3.5MM^2 & (1) 3.5MM^2 GROUND IN 28MM RIGID STEEL
CONDUIT.
PROVIDE TWO 125V, 20A, NEMA5-20R, WEATHER RESISTANT,
GFCI RECEPTACLE, SURFACE MOUNTED INSIDE ENCLOSURE.
NEW GROUND BUS BONDED TO ENCLOSURE. 10 OHMS OR LESS MUST
NEW 24 SPACE TERMINAL STRIP. NUMBER ALL SPACES 1-24.
LABEL ALL WIRING ENTERING ENCLOSURE WITH REVERSE
NUMBERING METHOD. PROVIDE TERMINAL WIRE JACKET.
VENT DRAIN - STAINLESS STEEL (HOFFMANN H2OMIT).
ECLIPSE CONTROLLER WITH ECY-16DI AND ECY PC-24 POWER SUPPLY.
PROVIDE BOND BUSHING FITTING TO BOND ENCLOSURE AND
EXTERNAL GROUNDING SYSTEM.
CAT-6 PATCH CABLE
ELECTRIC METER CABLE
FIBER OPTIC PATCH PANEL - 12 STRAND SC SINGLE MODE PATCH PANEL.
BREAKER FOR ECLIPSE / MEDIA CONVERTER.
BREAKER FOR CENTRALIZED CONTROLLER (EW-50J).
SURGE PROTECTIVE DEVICE FOR ECLIPSE / MEDIA CONVERTER /
CENTRALIZED CONTROLLER (EW-50J).
SURGE PROTECTIVE DEVICE FOR MODBUS.
STRUT CONDUIT SUPPORT
29 LISTED RIGID STEEL CONDUIT TO UNDERGROUND FEP CONDUIT
COUPLING
AND BREAKER.
TO ELECTRICAL PANEL BOARD
(PANEL M-H : POWER METER)
TO HEAT PUMP UNITS
TWISTED PAIR
CABLE IN 28MM
CONDUIT
30 PROVIDE TWISTED PAIR CABLE TO WATER METERS.
GENERAL NOTES:
1. WIRE/CABLE MANAGEMENT: INCLUDE LABELING FOR ALL
WIRES FROM DEVICE TO ITS TERMINATION LOCATION.
INCLUDE IN SHOP DRAWINGS PROVIDED TO THE
INSTALLATION FOR APPROVAL.
2. POWER AND GROUND WIRE COLORING CODES SHOULD MATCH
REQUIREMENT BY NEC.
BE PRESENT FOR GROUNDING OF THE EMCS PANEL. IF TESTED AND HIGHER
THAN 10 OHMS ADDITIONAL GROUNDING IS REQUIRED.
33 FUSED POWER
DISTRIBUTION
BLOCK
31 PANEL MOUNTED FUSED POWER DISTRIBUTION BLOCK
SEE ELECTRICAL FOR
GROUNDING SYSTEM
FINISHED GRADE
NEW EMCS ENCLOSURE. PROVIDE IP66 STAINLESS STEEL CABINET
IP66 STAINLESS STEEL
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
EM504
E M
C
D
E T
A I L
| Attachment 3 to FA520523R00040001 |
| A-101_Adn#1_20230613 |
| A-407_Adn#1_20230613 |
| S-103_Adn#1_20230613 |
| S-105_Adn#1_20230613 |
| E-002_Adn#1_20230613 |
| EM503_Adn#1_20230613 |
| EM504_Adn#1_20230613 |
File details come from the government source that posted it. Updated .