This document provides details for a federal contract solicitation for repair work on military family housing at Misawa Air Base in Japan. The solicitation was issued by the Department of the Air Force Pacific Air Forces for Project No. QKKA214009 to repair five Junior Non-Commissioned Officer homes located at 123, 125, 127, 129, and 291 Misawa Air Base. Offerors are required to provide repair services that include repairing and replacing damaged siding, doors, windows and other exterior components of the homes. The solicitation number is FA520523R0004 and responses are due by the date specified on the Federal Business Opportunities website.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE: 1:20000
0 400 800 1200m200
GRAPHIC SCALE:
HOKKAIDO
KYUSHU
SHIKOKU
HONSHU
IWO JIMA
CAMP ZAMA
SAGAMIHARA HOUSING AREA
SAGAMI GENERAL DEPOT
MISAWA AB
YOKOTA AB
NAF ATSUGI
YOKOSUKA NB
IKEGO
OKINAWA
CAMP FUJI
MCAS IWAKUNI
SASEBO NB
SCALE: 1:20000
SCALE: NTS
PROJECT LOCATION
NORTH
NORTH
APPLE GATE
HAUL ROUTE
LEVITOW GATE
MAIN GATE
FUJIMOTO.MIYA
KO.1288435894
Digitally signed by
FUJIMOTO.MIYAKO.1288435894
Date: 2023.03.07 07:56:50 +09'00'
HENRARD.JERE
ME.R.1362413504
Digitally signed by
HENRARD.JEREME.R.1362413
Date: 2023.02.27 17:18:45 +09'00'
BUTLER.GEON.
ENORRIS.JR.14
00234635
Digitally signed by
BUTLER.GEON.ENORRIS.JR
.1400234635 Date: 2023.03.01 18:55:20 +09'00'
GRANILLO.GABRI
EL.EDWARD.1523
404969
Digitally signed by
GRANILLO.GABRIEL.EDWARD.
1523404969 Date: 2023.03.02 07:49:41 +09'00'
SANTOSLOPEZ.A
LEXANDER.JAME
S.1187032683
Digitally signed by
SANTOSLOPEZ.ALEXANDER.J
AMES.1187032683
Date: 2023.03.02 13:35:45 +09'00'
WOO.JESSICA.LY
NNE.1574272765
Digitally signed by
WOO.JESSICA.LYNNE.157427
Date: 2023.03.02 14:38:16 +09'00'
FUKUSHI.OSA
MU.1513023991
Digitally signed by
FUKUSHI.OSAMU.1513023991
Date: 2023.03.02 16:17:16 +09'00'
KATCHMAR.KYLE.
MICHAEL.15039227
Digitally signed by
KATCHMAR.KYLE.MICHAEL.1503
922769 Date: 2023.03.03 13:32:17 +09'00'
KEALE.TRAVIS
.M.1180201374
Digitally signed by
KEALE.TRAVIS.M.1180201374
Date: 2023.03.03 13:43:54
+09'00' PRITCHETT.KEVIN.
W.1530362945 Digitally signed by
PRITCHETT.KEVIN.W.1530362945
Date: 2023.03.07 09:51:56 +09'00'
ARIAS.KAYLA.ANN.
1515991200
Digitally signed by
ARIAS.KAYLA.ANN.1515991200
Date: 2023.02.27 09:17:01 +09'00'
DURAN.DANIEL.1530015390
Digitally signed by
DURAN.DANIEL.1530015390
Date: 2023.03.24 15:09:10 +09'00'
DURAN.DANIEL.1530
015390
Digitally signed by
DURAN.DANIEL.1530015390
Date: 2023.03.24 15:10:42 +09'00'
Attachment 2 to RFP No. FA520523R0004 Date: 21 Feb 23
SHEET
NO.
IN
D
EX
O
F D
R
AW
IN
G
S
I N D E X O F D R A W I N G S
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
PA
N
TH
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
SHEET
ID SHEET TITLE
GENERAL
1 G-001 TITLE SHEET, LOCATION AND VICINITY MAP
2 G-002 INDEX OF DRAWINGS
3 G-003 GENERAL PROJECT INFORMATION
4 G-004 BUILDING CODE SUMMARY
5 G-005 CODE COMPLIANCE SITE PLAN
6 G-101 TYPICAL FIRST FLOOR PLAN - LIFE SAFETY
7 G-102 TYPICAL SECOND FLOOR PLAN - LIFE SAFETY
HAZARDOUS MATERIALS
8 H-101 HAZARDOUS MATERIALS REMOVAL PLAN - BLDG 123
9 H-102 HAZARDOUS MATERIALS REMOVAL PLAN - BLDG 125
10 H-103 HAZARDOUS MATERIALS REMOVAL PLAN - BLDG 291
CIVIL
11 C-001 GENERAL CIVIL NOTES, SYMBOLS AND ABBREVIATIONS
12 C-002 TOPOGRAPHIC SURVEY NOTES AND LIST OF TREES
13 C-101 CIVIL EXISTING CONDITIONS PLAN - B123, B125, B127, B129
14 C-102 CIVIL EXISTING CONDITIONS PLAN - B291
15 C-111 CIVIL DEMOLITION PLAN - B123
16 C-112 CIVIL DEMOLITION PLAN - B125
17 C-113 CIVIL DEMOLITION PLAN - B127
18 C-114 CIVIL DEMOLITION PLAN - B129
19 C-115 CIVIL DEMOLITION PLAN - B291
20 C-121 CIVIL UTILITY PLAN - WATER LINE "A"
21 C-122
CIVIL SITE AND UTILITY PLAN - B123
22 C-123
CIVIL SITE AND UTILITY PLAN - B125
23 C-124
CIVIL SITE AND UTILITY PLAN - B127
24 C-125
CIVIL SITE AND UTILITY PLAN - B129
25 C-126
CIVIL SITE AND UTILITY PLAN - B291
C-201 PROFILE - FIRE PROTECTION WATER LINE "A"
C-202 PROFILE - FIRE PROTECTION WATER LINE "B1"
C-203 PROFILE - FIRE PROTECTION WATER LINES "B2" "C" AND "D"
C-204 PROFILE - FIRE PROTECTION WATER LINE "E"
C-501 CIVIL DETAILS - 1
C-502 CIVIL DETAILS - 2
C-503 CIVIL DETAILS - 3
C-504 CIVIL DETAILS - 4
C-505 CIVIL DETAILS - 5
ARCHITECTURAL
A-001 ARCHITECTURAL TITLE SHEET; ARCHTIECTURAL SCOPE OF WORK, ABBREVIATIONS,
LEGEND AND NOTES
A-002 ARCHITECTURAL DEMOLITION KEYNOTES AND NEW WORK KEYNOTES
A-003 PARTIAL ARCHITECTURAL SITE PLAN B123, B125, B127, & B129
A-004 PARTIAL ARCHITECTURAL SITE PLAN B291
AD101 TYPICAL EXISTING & REMOVAL FIRST FLOOR PLAN AND FIRST FLOOR REFLECTED
CEILING PLAN43
AD102 TYPICAL EXISTING & REMOVAL SECOND FLOOR PLAN AND SECOND FLOOR REFLECTED
CEILING PLAN
AD103 TYPICAL EXISTING & REMOVAL LOWER ROOF AND UPPER ROOF FLOOR PLAN
AD201 TYPICAL EXISTING & REMOVAL EXTERIOR ELEVATIONS
AD202 TYPICAL EXISTING & REMOVAL EXTERIOR ELEVATIONS
A-100 BUILDING PLAN VARIATIONS AND NORTH ARROW
A-101 TYPICAL RENOVATED FIRST FLOOR PLAN
A-102 TYPICAL RENOVATED SECOND FLOOR AND LOWER ROOF PLAN
A-103 TYPICAL RENOVATED UPPER ROOF PLAN
A-104 TYPICAL RENOVATED FIRST FLOOR REFLECTED CEILING PLAN
A-105 TYPICAL RENOVATED SECOND FLOOR REFLECTED CEILING PLAN
A-201 TYPICAL RENOVATED EXTERIOR ELEVATIONS
A-202 TYPICA LRENOVATED EXTERIOR ELEVATIONS 2
A-301 TYPICAL BUILDING SECTIONS
A-302 SECTION THRU STAIR
A-311 PARTITION TYPES 1
A-312 PARTITION TYPES 2
A-313 PARTITION TYPES 3 AND FIRE RISER ENCLOSURE DETAIL
A-401 TYPICAL ENLARGED KITCHEN FLOOR PLAN AND INTERIOR ELEVATIONS
A-402 TYPICAL ENLARGED LAUNDRY & CLOSET ROOM FLOOR PLAN AND INTERIOR ELEVATIONS
A-403 TYPICAL ENLARGED BATHROOM FLOOR PLAN AND INTERIOR ELEVATIONS
A-404 TYPICAL ENLARGED LIVING ROOM FLOOR PLAN AND INTERIOR ELEVATIONS
A-405 TYPICAL ENLARGED BEDROOM 1 FLOOR PLAN AND INTERIOR ELEVATIONS
A-406 TYPICAL ENLARGED BEDROOM 2 FLOOR PLAN AND INTERIOR ELEVATIONS
A-407 TYPICAL ENLARGED STAIR ROOM FIRST FLOOR PLAN AND INTERIOR ELEVATIONS
A-408 TYPICAL ENLARGED STAIR ROOM SECOND FLOOR PLAN AND INTERIOR ELEVATIONS
A-501 B123 PORCH CANOPY PLAN, RCP, ROOF PLAN, SECTION AND ELEVATIONS
A-502 B125, B127, B129 PORCH CANOPY PLAN, RCP, ROOF PLAN, SECTION AND ELEVATIONS
A-503 B291 PORCH CANOPY PLAN, RCP, ROOF PLAN, SECTION AND ELEVATIONS
A-504 ROOF DETAILS
A-505 EXTERIOR DETAILS
A-506 INTERIOR DETAILS
A-507 CABINET DETAILS 1
A-508 CABINET DETAILS 2
A-601 DOOR SCHEDULE AND TYPES, HARDWARE SCHEDULE
A-602 WINDOW SCHEDULE AND TYPES
A-603 DOOR DETAILS
A-604 WINDOW DETAILS
A-605 ROOM FINISH SCHEDULE, MATERIAL & COLOR SCHEDULE
STRUCTURAL
S-001 GENERAL NOTES AND DESIGN CRITERIA
S-101 EXISTING FRAMING PLAN
S-102 MODIFIED FRAMING PLAN
S-103 PORCH CANOPY FRAMING PLAN AND ELEVATION FOR STEEL WORKS
S-104 STEEL WORKS DETAILS
S-105 FRAMING PLAN AND SECTION FOR CONCRETE FOUNDATION
S-106 PLAN AND SECTION FOR CONCRETE PORCH AND EXTERIOR STAIR
S-107 MISCELLANEOUS DETAILS - 1
S-108 MISCELLANEOUS DETAILS - 2
S-109 STRUCTURAL PLAN (FIRE ENCLOSURE)
FIRE PROTECTION
F-001 FIRE PROTECTION NOTES AND LEGEND
FD101 FIRE ALARM DEMOLITION PLANS
FX101 TYPICAL FIRST FLOOR PLAN - FIRE SPRINKLER
FX102 TYPICAL SECOND FLOOR PLAN - FIRE SPRINKLER
FA101 TYPICAL FIRST FLOOR PLAN - FIRE ALARM
FA102 TYPICAL SECOND FLOOR PLAN - FIRE ALARM
F-501 TYPICAL FIRE PROTECTION DETAILS
PLUMBING
P-001 PLUMBING GENERAL NOTES, LEGEND
PS101 PARTIAL PLUMBING SITE PLAN - B123, B125, B127, & B129
PS102 PARTIAL PLUMBING SITE PLAN - B291
PD101 B123, B125, B129 FIRST FLOOR PLUMBING DEMOLITION PLAN
PD102 B127 FIRST FLOOR PLUMBING DEMOLITION PLAN
PD103 B291 FIRST FLOOR PLUMBING DEMOLITION PLAN
PD104 SECOND FLOOR PLUMBING DEMOLITION PLAN
P-101 B123, B125, B129 FIRST FLOOR PLUMBING PLAN
P-102 B127 FIRST FLOOR PLUMBING PLAN
P-103 B291 FIRST FLOOR PLUMBING PLAN
P-104 SECOND FLOOR PLUMBING PLAN
P-501 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-602 SANITARY PIPING DIAGRAM
P-603 WATER PIPING DIAGRAM
MECHANICAL
M-001 MECHANICAL GENERAL NOTES, LEGEND
MS101 PARTIAL MECHANICAL SITE PLAN - B123, B125, B127 & B129
MS102 PARTIAL MECHANICAL SITE PLAN - B291
MD101 B123, B125, B129 FIRST FLOOR MECHANICAL DEMOLITION PLAN
MD102 B127 FIRST FLOOR MECHANICAL DEMOLITION PLAN
MD103 B291 FIRST FLOOR MECHANICAL DEMOLITION PLAN
MD104 SECOND FLOOR MECHANICAL DEMOLITION PLAN
M-101 B123, B125, B129 FIRST FLOOR MECHANICAL PLAN
M-102 B127 FIRST FLOOR MECHANICAL PLAN
M-103 B291 FIRST FLOOR MECHANICAL PLAN
M-104 B123, B125, B129 SECOND FLOOR MECHANICAL PLAN
M-105 B127 SECOND FLOOR MECHANICAL PLAN
M-106 B291 SECOND FLOOR MECHANICAL PLAN
M-301 MECHANICAL EXTERIOR ELEVATIONS
M-302 MECHANICAL EXTERIOR ELEVATIONS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
ELECTRICAL
E-001 ELECTRICAL SYMBOLS AND NOTES
E-002 ELECTRICAL NOTES AND ABBREVIATIONS
E-101 ELECTRICAL SITE PLAN - B119, B123, B125, B127, B129
E-102 ELECTRICAL SITE PLAN - B263, B291
E-103 FIRST FLOOR ELCTRICAL DEMOLITION PLAN (TYPICAL FOR ALL UNITS)
E-104 FIRST FLOOR LIGHTING DEMOLITION PLAN (TYPICAL FOR ALL UNITS)
E-105 SECOND FLOOR ELCTRICAL DEMOLITION PLAN (TYPICAL FOR ALL UNITS)
E-106 SECOND FLOOR LIGHTING DEMOLITION PLAN (TYPICAL FOR ALL UNITS)
E-201 B123, B125, B129 FIRST FLOOR ELECTRICAL PLAN
E-202 B127 FIRST FLOOR ELECTRICAL PLAN
E-203 B291 FIRST FLOOR ELECTRICAL PLAN
E-204 FIRST FLOOR LIGHTING PLAN (TYPICAL FOR ALL UNITS)
E-205 SECOND FLOOR ELECTRICAL PLAN (TYPICAL FOR ALL UNITS)
E-206 SECOND FLOOR LIGHTING PLAN (TYPICAL FOR ALL UNITS)
E-501 ELECTRTICAL DUCT SECTION DETAILS
E-502 MISCELLANEOUS ELECTRICAL DETAILS
E-503 MISCELLANEOUS ELECTRICAL DETAILS
E-504 LIGHT FIXTURE SCHEDULE
E-601 TYPICAL ONE LINE-DIAGRAM (B123, B125, B127, B129)
E-602 PANEL SCHEDULES
ET201 B123, B125, B129 FIRST FLOOR TELECOM PLAN
ET202 SECOND FLOOR TELECOM PLAN (TYPICAL FOR ALL UNITS)
EMCS
EM001 EMCS GENERAL NOTES, LEGEND
EM002 EMCS BLOCK DIAGRAM
EM003 EMCS ARCHITECTURE
EM101 B123, B125, B129 EMCS PLAN
EM102 B127 EMCS PLAN
EM103 B291 EMCS PLAN
EM501 EMCS DETAILS
EM502 EMCS DETAILS
EM503 EMCS DETAILS
EM504 EMCS DETAILS
EM505 EMCS DETAILS
EM506 POINTS LIST
EM507 ELECTRICAL DUCT SECTION DETAILS
EI101 EMCS SITE PLAN - B119, B123, B125, B127, B129
EI102 EMCS SITE PLAN - B263 AND B291
SHEET
NO.
SHEET
ID SHEET TITLE SHEET
NO.
SHEET
ID SHEET TITLE
ELECTRICAL (CONTINUED)( )ARCHITECTURAL (CONTINUED)( )
A-409 ENLARGED FIRE RISER ENCLOSURE PLANS AND SECTION
C-127 C-128
CIVIL UTILITY PLAN - WATER LINE "B1", "B2" AND "D"
CIVIL UTILITY PLAN - WATER LINE "C"
CIVIL DETAILS - 6
CIVIL DETAILS - 7
C-506 C-507
CONTRACTOR SHALL COMPLY WITH THE FOLLOWING CODES AND STANDARDS:
1. UNIFIED FACILITIES CRITERIA (UFC)
2. US AIR FORCE FAMILY HOUSING GUIDE (AFDG), AUGUST 2004
3. INTERNATIONAL BUILDING CODE (IBC), 2018
4. INTERNATIONAL MECHANICAL CODE (IMC), 2018
5. INTERNATIONAL PLUMBING CODE (IPC), 2018
6. INTERNATIONAL ENERGY CONSERVATION CODE (IECC), 2015
7. ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS, 2015
8. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 1, FIRE CODE, 2021
9. NFPA 70 NATIONAL ELECTRICAL CODE (NEC), 2020
10. NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2022
11. NFPA 101, LIFE SAFETY CODE, 2021
12. DEPARTMENT OF DEFENSE JAPAN ENVIRONMENTAL GOVERNING STANDARDS
(JEGS), 2022
13. JAPANESE INDUSTRIAL STANDARDS (JIS).
14. INSTALLATION DEVELOPMENT & DESIGN STANDARD, MISAWA AIR BASE 2005
15. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE), IEEE C2,
NATIONAL ELECTRICAL SAFETY CODE
16. AMERICAN CONCRETE INSTITUTE (ACI) 315, “MANUAL OF STANDARD PRACTICE FOR
DETAILING REINFORCED CONCRETE STRUCTURE”
17. ACI 318-19, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, 2019
18. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) 325, “STEEL CONSTRUCTION
MANUAL”
19. AMERICAN WELDING SOCIETY (AWS) D1.1, “STRUCTURAL WELDING CODE - STEEL”
20. STEEL STRUCTURES PAINTING COUNCIL (SSPC) “GOOD PAINTING PRACTICE” SSPC
PAINTING MANUAL
21. JAPANESE ARCHITECTURAL STANDARD SPECIFICATION (JASS) 5 FOR REINFORCED
CONCRETE WORKS
22. JASS 6 FOR STRUCTURAL STEEL WORKS FOR BUILDING CONSTRUCTION
23. AIR FORCE INSTRUCTION (AFI) 32-6000 HOUSING MANAGEMENT
24. AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE) 2019 ED. STANDARD 15
25. ASHRAE 2017 ED. FUNDAMENTALS
26. ASHRAE 62.2 VENTILATION AND ACCEPTABLE INDOOR AIR QUALITY IN RESIDENTIAL
BUILDINGS
27. AIR FORCE INSTRUCTION (AFI) 32-1023 DESIGN AND CONSTRUCTION STANDARDS
AND EXECUTION OF FACILITY CONSTRUCTION PROJECTS
28. DEPARTMENT OF THE AIR FORCE MANUAL (DAFMAN) 32-1084 STANDARD FACILITY
REQUIREMENTS
29. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) STANDARDS
30. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REGULATIONS
G
EN
ER
AL
P R
O
JE
C T
IN
FO
R M
AT
IO
N
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
THE CONTRACTOR SHALL PROVIDE ALL SUPERVISION, MANAGEMENT, QUALITY CONTROL, LABOR, TOOLS, EQUIPMENT, MATERIALS, AND PERFORMANCE OF ALL WORK NECESSARY TO CONSTRUCT THE RENOVATION OF BUILDINGS 123, 125, 127, 129, AND 291 AS DEPICTED IN THE CONTRACT DOCUMENTS TO INCLUDE:
INTERIOR DEMOLITION AND HAZARDOUS MATERIAL ABATEMENT; STRUCTURAL AND ARCHITECTURAL IMPROVEMENTS TO SUPPORT NEW BUILDING SYSTEMS; MAIN ROOF RECOATING; REPAINTING; NEW DOORS, WINDOWS, ROOFING AT CONCRETE EYEBROWS, FLOORING, KITCHEN AND BATH CABINETS, HANDRAILS, APPLIANCES, SMOKE DETECTORS, HVAC DUCTWORK, PLUMBING FIXTURES AND PIPING, AND ELECTRICAL
SYSTEMS.
PROVIDE NEW FIRE PROTECTION WATER LINES AND FIRE HYDRANTS TO FIRE RISER ENCLOSURE AND
SPRINKLER SYSTEMS.
DEMOLITION OF STEAM-SOURCED HOT WATER SPACE HEATING SYSTEM AND PROVIDE AN ENERGY
EFFICIENT AIR SOURCE HEAT PUMPS FOR AIR CONDITIONING AND HEATING.
PROVIDE NEW SMART METERS FOR DOMESTIC WATER AND ELECTRICITY, AND EMCS FOR INTEGRATION
WITH MISAWA AIR BASE EMCS.
1. CONTRACT DOCUMENTS CONSIST OF THE COMBINATION OF DRAWINGS AND
SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIREMENTS
CONTAINED THEREIN. SPECIFICATIONS AND DRAWINGS ARE COMPLEMENTARY,
AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL;
PERFORMANCE BY THE CONTRACTOR SHALL BE REQUIRED ONLY TO THE EXTENT
CONSISTENT WITH THE CONTRACT DOCUMENTS AND REASONABILITY INFERABLE
FROM THEM AS BEING NECESSARY TO PRODUCE THE INTENDED RESULTS.
VARYING LEVELS OF DETAIL BETWEEN DRAWINGS AND SPECIFICATION, OR
AMONGST PLANS, ELEVATIONS, SECTIONS, DETAILS AND SCHEDULES, DOES NOT
CONSTITUTE OMISSION OF INFORMATION, NOR DOES IT RELIEVE THE CONTRACTOR
FROM OBLIGATION TO CONTRACT DOCUMENTS.
2. INFORMATION INDICATED ON THESE DRAWINGS HAS BEEN OBTAINED FROM A
LIMITED AMOUNT OF FIELD INVESTIGATION AND AVAILABLE SOURCES AT THE TIME
THE DRAWINGS WERE PREPARED. THE GENERAL CONTRACTOR SHALL VERIFY ALL
EXISTING CONDITIONS AND DIMENSIONS AT THE JOB SITE. THE CONTRACTOR
SHALL NOTIFY THE CONTRACTING OFFICER OF ANY DISCREPANCIES, OMISSIONS,
AND CONFLICTS BEFORE COMMENCING WORK.
3. THESE DRAWINGS ARE SUPPLIED TO THE GENERAL CONTRACTOR AND OTHERS
FOR THEIR USE ON THIS SPECIFIC PROJECT. ALL COPIES OF THESE DRAWINGS
SHALL REMAIN THE PROPERTY OF THE GOVERNMENT AND SHALL NOT BE REUSED
OR REPRODUCED WITHOUT PERMISSION OF THE CONTRACTING OFFICER.
4. THE ORGANIZATION OF THESE DRAWINGS IS NOT INTENDED TO CONTROL THE
DIVISION OF WORK AMONG THE SUB-CONTRACTORS. THE DIVISION OF WORK
SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
5. THE GENERAL CONTRACTOR SHALL MAINTAIN OR PROVIDE ACCESS TO CONCEALED
SPACES WITHIN THE EXISTING BUILDING IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE (IBC) 2018 EDITION.
6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL
DAMAGES TO EXISTING AREAS CAUSED BY THIS PROJECT TO THE ORIGINAL
CONDITION AS DIRECTED BY THE CONTRACTING OFFICER/REPRESENTATIVE.
7. SAVE ALL EXISTING TREES WITHIN AREA TO RECEIVE NEW WORK, UNLESS
OTHERWISE INDICATED. COORDINATE WITH THE CONTRACTING OFFICER IF THERE
IS A CONFLICT. WHERE TREE REMOVAL IS UNAVOIDABLE, NEW TREES OF A SIMILAR
TYPE MUST BE PLANTED NEAR THE LOCATION WHERE THE TREE WAS REMOVED.
TREE REPLACEMENT SHALL BE ONE NEW TREE FOR EACH TREE THAT IS REMOVED.
8. IN THE MILITARY FAMILY HOUSING NEIGHBORHOODS WHERE THERE ARE UNITS
WHICH ARE OUTSIDE OF THE SCOPE OF WORK, THE CONTRACTOR SHALL
COORDINATE ANY DISRUPTION OF SERVICES CAUSED BY WORK IN THIS PROJECT.
THIS WOULD INCLUDE, BUT NOT BE LIMITED TO, DISRUPTION IN THE UTILITY LOOP
FOR UNITS NOT BEING RENOVATED.
9. REFER TO HAZARDOUS MATERIALS DRAWINGS AND ASBESTOS HAZARD CONTROL
ACTIVITIES SPECIFICATION SECTION FOR TESTING, REMOVAL, AND DISPOSAL
PROCEDURES REGARDING ABATEMENT WORK.
10. ON A QUARTERLY BASIS, THE CONTRACTOR SHALL SUBMIT A RECYCLING REPORT.
THIS REPORT LISTS THE AMOUNT OF CONSTRUCTION MATERIAL THAT IS
LANDFILLED. THE REPORT SHALL ALSO LIST THE AMOUNT OF CONSTRUCTION
MATERIAL THAT IS RECYCLED AND SHOW THAT BY TYPE (I.E., METALS, PLASTIC,
GWB, ETC.).
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING TEMPORARY HEAT IN
ALL MFH UNITS WHERE WORK IS TO BE PERFORMED DURING THE HEATING SEASON.
THE CONTRACTOR SHALL PROVIDE ALL NECESSARY HEATING EQUIPMENT AND
UTILITY CONNECTIONS, BUT NOT LIMITED TO MAINTAINING INTERIOR SPACE
TEMPERATURES IN THE MFH UNITS AT 20 DEGREES C (68 DEGREES F) DURING
CONSTRUCTION AND INTERRUPTION OF EXISTING HEATING EQUIPMENT.
12. THE CONTRACTOR SHALL SURVEY EXISTING CONDITIONS AT EXTERIOR WALLS
PRIOR TO INSTALLATION OF MECHANICAL, ELECTRICAL, AND EMCS EQUIPMENT,
AND PRIOR TO INSTALLATION SHOP DRAWING SUBMITTAL. COORDINATE WITH BASE
SUCH THAT COR IS PRESENT FOR SURVEY OF ALL UNITS.
13. THE CONTRACTOR SHALL HAVE AN ENGLISH-SPEAKING REPRESENTATIVE AT ALL
SITES AT ALL TIMES. REFER TO THE GENERAL CONTRACT REQUIREMENTS
SPECIFICATION SECTION.
14. THE INTENT IS TO RESTRICT OUTDOOR WORK DURING THE WINTER (I.E., PAINT,
CONCRETE, ROOF WORK, ETC.). HOWEVER, THERE IS NO WINTER EXCLUSION
PERIOD. CONTRACTOR SHALL MAKE ALL NECESSARY PROVISIONS FOR WINTER
WORK AT NO ADDITIONAL COST TO GOVERNMENT.
15. HVAC CONTROL SYSTEM (EMCS) SHALL BE THE PROPERTY OF THE USAF AT THE
END OF THE PROJECT, IN ITS ENTIRETY. THIS SHALL INCLUDE, BUT NOT BE LIMITED
TO, ALL PROGRAMMING AND SOFTWARE LICENSES. CONTROLS CONTRACTOR
SHALL PROVIDE THE GOVERNMENT FULL AND UNRESTRICTED ACCESS TO ALL
ASPECTS OF EMCS HEAD-END AND BACK-END. THERE SHALL NOT BE ANY ASPECT
OF EMCS THAT IS INACCESSIBLE TO THE GOVERNMENT.
THE CONTRACTOR SHALL PROVIDE ALL PLANT, SUPERVISION, MANAGEMENT, QUALITY CONTROL, LABOR, TOOLS, EQUIPMENT, APPLIANCES, MATERIALS, AND PERFORMANCE OF ALL WORK NECESSARY TO CONSTRUCT IMPROVEMENTS TO MILITARY FAMILY HOUSING (MFH) CONSISTING OF TWENTY (20) TWO-BEDROOM JUNIOR NON-COMMISSIONED OFFICER (JNCO) QUARTERS, LOCATED IN THE MAIN BASE
AREA OF MISAWA AIR BASE, JAPAN.
PROJECT DESIGN
GUIDES, CODES AND
STANDARDS
SCOPE OF WORK
PROJECT INFORMATION GENERAL NOTES
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
License Expiration Date 06/30/2024
G-004
BU
IL
D
IN
G C
O D
E
SU
M M
AR
Y
BUILDING CODE SUMMARY:
INTERNATIONAL CODES, INTERNATIONAL CODE COUNCIL:
IBC
NATIONAL FIRE CODES, NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS INCLUDING:
NFPA 1 FIRE CODE, 2021
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2022
UNIFIED FACILITIES CRITERIA:
UFC 1-200-01 DOD BUILDING CODE, 8 OCTOBER 2019
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST
2016, CHANGE 6, 6 MAY 2021
INTERNATIONAL BUILDING CODE, 2018
NFPA 101 LIFE SAFETY CODE, 2021
PROJECT ADDRESS:
MISAWA AIR BASE, JAPAN
PROJECT DESCRIPTION:
RENOVATION OF TWENTY (20) JNCO HOUSING UNITS IN FIVE (5) BUILDINGS (BUILDINGS 123,125,127, 129 AND
291). THERE ARE FOUR (4) UNITS PER BUILDING.
OCCUPANCY IBC OCCUPANCY NFPA OCCUPANCY
APARTMENT HOUSES GROUP R-2 EXISTING APARTMENT (CHAPTER 31)
CONSTRUCTION TYPE:
PROVIDED
APARTMENT HOUSES TYPE II-B
ALLOWABLE AREA AND HEIGHT (TABLE 506.2):
OCCUPANCY ALLOWABLE ACTUAL
GROUP AREA AREA
APARTMENT HOUSES
(SEPARATED) 2,659 SM 492 SM
ALLOWABLE HEIGHT AND NUMBER OF STORIES (504.3 AND 504.4)
ALLOWABLE ACTUAL
BUILDING HEIGHT STORIES HEIGHT STORIES
APARTMENT HOUSES 16.76 M 4 6.2 M 2
EXPOSURES (TABLE 601, 704.8):
EXPOSURE SEPARATION EXTERIOR UNPROTECTED
NORTH > 60 FT 3.048 M 0 HR UNLIMITED
EAST > 60 FT 3.048 M 0 HR UNLIMITED
SOUTH > 60 FT 3.048 M 0 HR UNLIMITED
WEST > 60 FT 3.048 M 0 HR UNLIMITED
CONSTRUCTION REQUIREMENTS (TABLE 601):
TYPE II-B:
REQUIRED PROVIDED
BUILDING ELEMENT MATERIAL RATING RATING SECTION
STRUCTURAL FRAME NON-COMBUSTIBLE 0 HR 0 HR TABLE 601
BEARING WALLS - EXT NON-COMBUSTIBLE 0 HR 0 HR TABLE 601
BEARING WALLS - INT NON-COMBUSTIBLE 0 HR 0 HR TABLE 601
NONBEARING WALLS - EXT NON-COMBUSTIBLE 0 HR 0 HR TABLE 601
SEPARATION > 30 FT NON-COMBUSTIBLE 0 HR 0 HR TABLE 602
NONBEARING WALLS - INT NON-COMBUSTIBLE 0 HR 0 HR TABLE 601
FLOORS NON-COMBUSTIBLE 0 HR 0 HR TABLE 601
ROOF NON-COMBUSTIBLE 0 HR 0 HR TABLE 601
INTERIOR FINISH AND INTERIOR FLOOR FINISH (NFPA 101):
OCCUPANCY EXITWAYS STAIR ENCLOSURE RESIDENTIAL UNIT OTHER AREAS
INTERIOR FINISH:
A, B A C A, B, C
INTERIOR FLOOR FINISH: I,II I,II I,II I,II
INSULATION (UFC 3-600-01):
CONDITION FLAMESPREAD SMOKE DEVELOPMENT
EXPOSED < 75 <150
CONCEALED SPACE < 25 < 50
OCCUPANT LOAD FACTOR (TABLE 7.3.1.2, NFPA 101)
APARTMENT BUILDINGS 18.6 SM/PERSON
TOTAL CALCULATED OCCUPANT LOAD
FIRST FLOOR = 13
SECOND FLOOR = 12
TOTAL = 25
EXIT QUANTITY AND CAPACITY:
NUMBER OF EXITS PER UNIT CAPACITY (PERSONS)
FLOOR REQUIRED PROVIDED REQUIRED PROVIDED
FIRST FLOOR 1 1 143 13
SECOND FLOOR 1 1 143 12
CAPACITY OF MEANS OF EGRESS SUMMARY (NFPA 101):
THE MEANS OF EGRESS CONSISTS OF AN INTERIOR EXIT STAIR ENCLOSURE, DOORS, AND AN EXTERIOR
STAIR ENTRANCE STAIR.
EGRESS CAPACITY FOR A DOOR AS A MEANS OF EGRESS IS 5 MM PER PERSON AND 7.6 MM PER PERSON
FOR THE EGRESS STAIRS (NFPA 101, TABLE 7.3.3.1).
INTERIOR STAIRWAY: MINIMUM WIDTH OF THE EXISTING STAIR IS REQUIRED TO BE 915 MM (36 INCHES) IN ACCORDANCE WITH NFPA 101, TABLE 7.2.2.2.1.1(B). A 1088 MM (43 INCH) WIDTH IS
PROVIDED.
EXTERIOR STAIRWAY: MINIMUM WIDTH OF THE EXISTING STAIR IS REQUIRED TO BE 915 MM (36 INCHES) IN ACCORDANCE WITH NFPA 101, TABLE 7.2.2.2.1.1(A). A 1088 MM (43 INCH) WIDTH IS
PROVIDED. THE RISER HEIGHT MUST BE A MINIMUM OF 100 MM AND A MAXIMUM OF 180 MM
ACCORDING TO TABLE 7.2.2.2.1.1(A). THE EXTERIOR STAIR WILL BE PROVIDED A RISER HEIGHT OF
178 MM, WHICH IS CODE COMPLIANT.
1088 MM/PERSON/7.6 MM = 143 PERSONS CAPACITY
EXIT ARRANGEMENT:
TRAVEL DISTANCE FROM UNIT TRAVEL DISTANCE FROM INSIDE
DOOR TO EXIT UNIT TO UNIT DOOR
FLOOR ALLOWED ACTUAL ALLOWED ACTUAL
FIRST FLOOR 10.7 M 0 M 23 M 14.5 M
SECOND FLOOR 10.7 M 0 M 23 M 14.5 M
FIRE HYDRANT COVERAGE:
IT IS REQUIRED BY NFPA 1 SECTION 18.5.3 THAT THE MAXIMUM DISTANCE BETWEEN A FIRE HYDRANT AND THE CLOSEST POINT ON A BUILDING IS 122 M. COMPLIES, DISTANCE FROM ALL BUILDINGS TO THE CLOSEST
FIRE HYDRANT IS WITHIN 122 M.
MEANS OF EGRESS ILLUMINATION:
REQUIRED AND PROVIDED. EXITS ARE ILLUMINATED TO VALUES OF NOT LESS THAN ONE (1) FOOTCANDLE, MEASURED AT WALKING SURFACE.
EMERGENCY LIGHTING:
NOT REQUIRED FOR TWO STORY BUILDINGS WITH LESS THAN 12 UNITS.
MARKING OF MEANS OF EGRESS:
NOT REQUIRED AS THE DWELLING UNITS ARE NOT REQUIRED TO BE PROVIDED WITH MORE THAN ONE EXIT.
FIRE DETECTION AND ALARM SYSTEM REQUIREMENTS (UFC 3-600-01, 34-6.1.3):
NFPA 101, 30.3.4.1.1 DOES NOT REQUIRE A FIRE ALARM SYSTEM FOR APARTMENT BUILDING OCCUPANCIES WHERE THERE ARE LESS THAN 4 STORIES AND LESS THAN 12 DWELLING UNITS. ALL THE BUILDINGS IN THIS
PROJECT MEET THE REQUIREMENTS FOR EXEMPTION FROM A FIRE ALARM SYSTEM.
INTERCONNECTED SMOKE ALARMS ARE REQUIRED IN ACCORDANCE WITH UFC 3-600-01. MULTI-STATION SMOKE ALARMS CONNECTED TO A 120 VAC LIGHTING CIRCUIT ARE BEING PROVIDED IN EVERY SLEEPING
ROOM, THE HALLWAYS LEADING TO THE SLEEPING ROOMS, AND ON EACH LEVEL OF THE UNIT.
IT IS WITHIN THE SCOPE OF WORK TO PROVIDE SUPERVISION FOR NFPA 13R FIRE SPRINKLER SYSTEMS TO CONNECT TO THE BASE-WIDE REPORTING SYSTEM. THE REPORTING SYSTEM WILL CONSIST OF A FIRE ALARM PANEL, ANTENNA, TRANSCIEVER, AND WILL REQUIRE A CEILING SMOKE DETECTOR AND MANUAL
PULL STATION WITHIN THE SPRINKLER RISER ENCLOSURE.
FIRE SUPPRESSION SYSTEM REQUIREMENTS (NFPA 101, 31.5 & UFC 3-600-01, 34-6.2):
A FIRE SPRINKLER SYSTEM IS REQUIRED BECAUSE THE FACILITY RENOVATION COST IS MORE THAN 50
PERCENT OF THE REPLACEMENT COST.
AN AUTOMATIC, MONITORED, WET FIRE SPRINKLER SYSTEM WILL BE PROVIDED FOR EACH BUILDING. THE FIRE SPRINKLER SYSTEM DESIGN WILL BE IN ACCORDANCE WITH NFPA 13R. THE HEATING WITHIN THE HOMES WILL BE SUFFICIENT TO KEEP SPRINKLER PIPES FROM FREEZING, ALLOWING FOR INSTALLATION OF
A WET-PIPE SYSTEM.
ONE SPRINKLER RISER WILL BE PROVIDED FOR EACH BUILDING WITHIN ITS OWN HEATED EXTERIOR ENCLOSURE. RISERS WILL BE EQUIPPED WITH A PADLOCKED DOUBLE CHECK VALVE AND A MONITORED WATERFLOW SWITCH. EACH RISER ENCLOSURE WILL HAVE ONE 2 ½ INLET FIRE DEPARTMENT CONNECTION
(FDC) IN ACCORDANCE WITH NFPA 13R, 6.11.1.
NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2022
NFPA 13R STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS IN
LOW-RISE RESIDENTIAL OCCUPANCIES, 2022
UFC 4-711-01 FAMILY HOUSING, 10 AUGUST 2018
FA
FA
FA
FA
FA
FA
FA
FA
FA
FA
EXSITING FIRE HYDRANT
EXSITING FIRE HYDRANT
3.048 M SEPARATION
DISTANCE , TYP
3.048 M SEPARATION
DISTANCE , TYP
3.048 M SEPARATION
DISTANCE , TYP
3.048 M SEPARATION
DISTANCE , TYP
PUMP HOUSE B119
EXISTING FIRE
HYDRANT
RELOCATED
FIRE HYDRANT
85 M FIRE HYDRANT
COVERAGE
76 M FIRE HYDRANT
COVERAGE
83 M FIRE HYDRANT
COVERAGE
69 M FIRE HYDRANT
COVERAGE
FD
FD
FD
FD
74 M FIRE HYDRANT
COVERAGE
10 M WIDE FIRE
ACCESS LANE
6.5 M WIDE FIRE
ACCESS LANE
38 M BETWEEN
FDC HYDRANT
41 M FROM FDC
TO HYDRANT
36 M BETWEEN
FDC HYDRANT
40 M BETWEEN FDC
AND HYDRANT
FA
FA
FA
FA
FA
FA
EXSITING FIRE HYDRANT
EXSITING FIRE HYDRANT
3.048 M
SEPARATION
DISTANCE , TYP
PUMP HOUSE B263
EXISTING FIRE
HYDRANT
FD
9.6 M WIDE FIRE
ACCESS LANE
EXISTING FIRE
HYDRANT
17 M FROM FDC
TO HYDRANT
FA FIRE DEPARTMENT ACCESS
FIRE HYDRANT
SITE PLAN LEGEND
ASSUMED PROPERTY LINE
FIRE DEPARTMENT ACCESS POINTFD
G-005
C O
D E
C O
M
PL
AI
N
C E
SI
TE
P
LA
N
CODE COMPLIANCE SITE PLAN - BLDG 123, 125, 127, & 1291
CODE COMPLIANCE SITE PLAN - BLDG 2912 NORTH
NORTH
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
License Expiration Date 06/30/2024
0 10M
SCALE: 1:400
20M
SCOPE OF WORK NOTES
THE CONTRACTOR SHALL PROVIDE ALL SUPERVISION, MANAGEMENT, QUALITY
CONTROL, LABOR , TOOLS, EQUIPMENT, MATERIALS, AND PERFORMANCE OF ALL
WORK NECESSARY TO CONSTRUCT THE RENOVATION OF BUILDINGS 123, 125, 127,
129 AND 291 AS DEPICTED IN THE CONTRACT DOCUMENTS TO INCLUDE:
INTERIOR DEMOLITION AND HAZARDOUS MATERIAL ABATEMENT; STRUCTURAL
AND ARCHITECTURAL IMPROVEMENTS TO SUPPORT NEW BUILDING SYSTEMS;
MAIN ROOF RECOATING; REPAINTING; NEW DOORS; WINDOW, ROOFING AT
CONCRETE EYEBROWS, FLOORING, KITCHEN AND BATH CABINETS, HANDRAILS,
APPLIANCES, SMOKE DETECTORS, HVAC DUCTWORK, PLUMBING FIXTURES AND
PIPING, AND ELECTRICAL SYSTEMS.
PROVIDE NEW FIRE PROTECTION WATER LINES AND FIRE HYDRANTS TO FIRE
RISER ENCLOSURE AN SPRINKLER SYSTEMS.
DEMOLITION OF STEAM-SOURCED HOT WATER SPACE HEATING SYSTEM AND
PROVIDE AN ENERGY EFFICIENT AIR SOURCE HEAT PUMPS FOR AIR
CONDITIONING AND HEATING.
PROVIDE NEW SMART METERS FOR DOMESTIC WATER AND ELECTRICITY, AND
EMCS FOR INTEGRATION WITH MISAWA AIR BASE EMCS.
BEDRM 1
BATH
LIVING CLO
TERRACE
STAIR
RM
BATH
CLO
LIVING
REF
DW
W
D
SK
REF
CLO
RAN
SK
LAUNDRY LAUNDRY
HALL
BEDRM 2
CLO
ENTRY/PORCH
CLO
TERRACE
BEDRM 1
BEDRM 2
CLO
RAN
DW
W
D
DINING/KITDINING/KIT
HALL
STAIR
TRASHTRASH
STOR
STOR
STOR
STOR
CLO CLOLN
CLOCLO
LN
ACCESS
PANEL (E)
FIRE RISER
ENCLOSURE
PROVIDE FALL PROTECTION
DEVICES FOR ALL WINDOWS,
TYPICAL
PROVIDE EMERGENCY
ESCAPE WINDOWS 1120 MM
ABOVE FINISHED FLOOR IN
BEDROOMS , TYPICAL1318.6
R-2
APARTMENT
EXTERIOR STAIR AND HANDRAIL
MUST COMPLY WITH NFPA 101,
TABLE 7.2.2.2.1 (A)
10010 B
BUSINESS
OCCUPANT LOAD
(PERSONS)OCCUPANT LOAD
FACTOR (SM /PERSON)
NFPA 101
OCCUPANCY IBC OCCUPANCY
OCCUPANCY LEGEND
SPACE AREA (SM)
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
License Expiration Date 06/30/2024
G-101
TY
PI
C
AL
F
IR
ST
F
LO
O
R P
LA
N
LI
FE
S
AF
ET
Y
TYPICAL FIRST FLOOR PLAN - LIFE SAFETY1 0 1000
SCALE: 1:50
BEDRM 1
BATH
LIVING CLO
BATH
LIVING
REF
DW
W
D
SK
REF
CLO
RAN
SK
LAUNDRY LAUNDRY
HALL
BEDRM 2
CLO
BEDRM 1
BEDRM 2
CLO
RAN
DW
W
D
DINING/KITDINING/KIT
HALL
BALCONY BALCONY
HALL
CLOCLO
CLOLNCLO LN
STAIR
1218.6 R-2
APARTMENT
PROVIDE EMERGENCY
ESCAPE WINDOWS 1120 MM
ABOVE FINISHED FLOOR IN
BEDROOMS , TYPICAL
10010 B
BUSINESS
OCCUPANT LOAD
(PERSONS)OCCUPANT LOAD
FACTOR (SM /PERSON)
NFPA 101
OCCUPANCY IBC OCCUPANCY
OCCUPANCY LEGEND
SPACE AREA (SM)
PROVIDE FALL PROTECTION
DEVICES FOR ALL WINDOWS,
TYPICAL
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
License Expiration Date 06/30/2024
G-102
TY
PI
C
AL
S
EC
O N
D F
LO
O
R P
LA
N
LI
FE
S
AF
ET
Y
TYPICAL SECOND FLOOR PLAN - LIFE SAFETY1 0 1000
SCALE: 1:50
STOR
STOR
STOR
BEDRM 2 LIVING
BATH
DW
KIT
TRASH
REF
BEDRM 1 DINING
DW
R
S
UP
S
R
DW
ENTRY
KIT
REF
DINING BEDRM 1
DW
STO STO
LIVING
BATH
BEDRM 2
1 2 3 4 5 6
A
B
C
D
9 195 3 760 9 195
22 150
BALCONY
DW
BALCONY
BEDRM 2 LIVING
CLO
BATH
DW
CLO
KIT
REFBEDRM 1 DINING
R
S
R
S
DW
KIT
REF
DN DW
STO STO
BATH
1 2 3 4 5 6
A
B
C
D
9 195 3 760 9 195
22 150
20 330
TERRACE TERRACE
BEDRM 2LIVING
CLO
CLO
BEDRM 1DINING
1 1 1 1
3 3
3 3
CLO
CLO 11
1 1
CLO
CLO1 1
STAIR
RM
HAZARDOUS MATERIAL REMOVAL NOTES:
1. THE IDENTITIES, LOCATIONS, AND QUANTITIES OF HAZARDOUS MATERIALS SHOWN ARE AS DESCRIBED IN THE HAZARDOUS MATERIALS REPORT ENTITLED “HAZARDOUS MATERIALS INSPECTION REPORT" BY ENVIRONMENTAL SCIENCE CORPORATION, 21 JANUARY 2022. FIELD-VERIFY THE PRESENCE AND QUANTITY OF HAZARDOUS MATERIALS IDENTIFIED IN THE HAZMAT REPORT AND IMMEDIATELY REPORT ANY DISCREPANCIES TO THE
CONTRACTING OFFICER.
2. IF HIDDEN OR OTHER SUSPECT POTENTIALLY HAZARDOUS MATERIAL, WHICH HAS NOT BEEN PREVIOUSLY CHARACTERIZED, IS ENCOUNTERED DURING DEMOLITION OR RENOVATIONS, THE SUSPECT MATERIAL SHALL BE ASSUMED HAZARDOUS UNTIL PROVEN OTHERWISE BY A QUALIFIED INSPECTOR. DO NOT DISTURB THE MATERIAL AND IMMEDIATELY REPORT TO THE CONTRACTING OFFICER AND OBTAIN CONCURRENCE TO IDENTIFY, SAMPLE, ANALYZE, AND EVALUATE SUCH MATERIAL IN ACCORDANCE WITH PROJECT SPECIFICATIONS.
3. DEMOLITION MUST INCLUDE ENVIRONMENTAL ABATEMENT OF HAZARDOUS MATERIALS INCLUDING, BUT NOT LIMITED TO, ASBESTOS, PCBS, MERCURY CONTAINING LAMPS AND SWITCHES, ETC. INSPECT, IDENTIFY, REMOVE AND DISPOSE OF ALL HAZARDOUS MATERIALS IN ACCORDANCE WITH PROJECT SPECIFICATIONS, OSHA, JEGS, AND PERTINENT GOJ REGULATIONS. WHERE SUCH PROVISIONS DIFFER, THE MORE STRINGENT SHALL APPLY.
4. VERIFY TEMPORARY STORAGE AREA FOR ALL HAZARDOUS MATERIALS FOR DISPOSAL WITH THE CONTRACTING
OFFICER.
5. SECURE THE WORK AREA, PROTECT ADJOINING AREAS PRIOR TO DISTURBING ANY MATERIAL FOR THE ABATEMENT ACTIVITY. MAINTAIN CRITICAL BARRIERS, ISOLATION, AND WARNING SIGNS AS NECESSARY DURING ALL ABATEMENT OPERATIONS, UNTIL FINAL CLEARANCE HAS BEEN APPROVED FOR EACH WORK AREA. PROTECT ALL SURROUNDING AREAS, INCLUDING SOIL, FROM HAZARDOUS MATERIALS THROUGHOUT ABATEMENT AND DEMOLITION ACTIVITIES.
6. REMOVE, HANDLE, AND DISPOSE OF ALL ASBESTOS-CONTAINING MATERIALS PRIOR TO WORK BY OTHER TRADES, USING PROCEDURES OUTLINED IN THE SPECIFICATIONS AND AS DETAILED IN THE ASBESTOS HAZARD ABATEMENT
PLAN.
7. PAINTS WITH LEAD BASED PAINT WAS NOT IDENTIFIED.
8. VERIFY LIGHTING BALLASTS FOR PRESENCE OF PCBS, SUBSEQUENTLY REMOVE AND SEGREGATE PCB-CONTAINING AND NON-PCB CONTAINING BALLASTS FOR LIGHTING FIXTURES. SEGREGATE BALLASTS BY US-MADE AND FOREIGN-MADE BALLASTS, STORE IN ACCORDANCE WITH JEGS. COORDINATE WITH THE CONTRACTING OFFICER
FOR STORAGE AND TURN-IN REQUIREMENTS.
9. INSPECT, IDENTIFY, REMOVE INTACT, AND DISPOSE OF FLUORESCENT AND HIGH INTENSITY DISCHARGE (HID) LIGHT BULBS SUSPECT FOR CONTAINING MERCURY IN ACCORDANCE WITH THE PCB AND LAMP REMOVAL WORK PLAN.
10. INSPECT, IDENTIFY, REMOVE AND DISPOSE OF SMOKE DETECTORS AND/OR EXIT SIGNS WITH POSSIBLE RADIOACTIVE MATERIALS IN ACCORDANCE WITH OSHA, JEGS, AND PERTINENT GOJ REGULATIONS AND TURN INTO
MISAWA AB HOUSING MAINTENANCE FOR DISPOSAL.
11. REMOVE AND RECYCLE OR DISPOSE OF MOUNTED EQUIPMENT BATTERIES (NI-CAD, LITHIUM-ION, MAGNESIUM-ION, ETC) IN ACCORDANCE WITH JEGS AND PERTINENT GOJ REGULATIONS.
12. CONTRACTOR SHALL SUBMIT AND HAVE APPROVED ACM ABATEMENT PLAN PRIOR TO START OF HAZMAT REMOVAL
IN ACCORDANCE WITH SECTION 02 82 00.
13. CONTRACTOR SHALL CONDUCT PREPARATORY MEETING WITH APPROVED ACM ABATEMENT PLAN AND ACTIVITY HAZARD ANALYSIS (AHA) PRIOR TO START OF HAZMAT REMOVAL IN ACCORDANCE WITH SECTION 02 82 00.
14. CONTRACTOR SHALL COORDINATE ALL HAZMAT REMOVAL WORK WITH ARCHITECTURAL DEMOLITION DRAWINGS.
MATERIALS NOT DISTURBED BY SELECTIVE DEMOLITION SHALL BE PROTECTED IN PLACE.
15. ALL EXISTING GYPSUM BOARD IS ASSUMED TO EXCEED THE REGULATORY LIMITS FOR CADMIUM AND ARSENIC FOR 'SPECIALLY CONTROLLED INDUSTRIAL WASTE (SCIW)' DISPOSAL CRITERIA IN JAPAN. REFER TO JEGS TABLE 16.7. ALL DEMOLITION OF GYPSUM BOARD SHALL FOLLOW THE REQUIREMENTS OF THE JEGS AND JAPAN MINISTRY OF THE ENVIRONMENT. ALL GYPSUM BOARD MUST BE DISPOSED AT A LICENSED CONTROLLED LANDFILL.
16. ASBESTOS CONTAINING MATERIALS NOT DETECTED IN BUILDINGS 127, 129 AND MECHANICAL BUILDINGS 191 AND 263.
REFER TO THE PROJECT HAZARDOUS MATERIALS INSPECTION REPORT.
1ST FLOOR PLAN
A5 HAZARDOUS MATERIALS REMOVAL PLAN - B123
NOT TO SCALE
2ND FLOOR PLAN
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
H
AZ
AR
D
O U
S M
AT
ER
IA
LS
R
EM
O
VA
L
PL
AN
BL
D
G B
H-101
FLOORING VINYL TILE WITH GREY MASTIC 49 SM
ASBESTOS CONTAINING MATERIAL
ITEM ACM DESCRIPTION QUANTITYLOCATIONS
LEGEND
FLOORING VINYL SHEET WITH GREY MASTIC 104 SM2
CARPET FLOOR WITH GREY MASTIC 167 SM3
"A", "B", KITCHEN, DINING AND LIVING ROOM.
"C", "D" KITCHEN
"A", "B" BEDROOMS, "C", "D" LIVING ROOMS,
DINING, BEDROOMS
ALL CLOSETS AND "C", "D" ENTRANCE,
STAIR RM
BALCONY
DW
BALCONY
BATH
DW
KIT
REF
R
S
R
S
DW
KIT
REF
DN DW
BATH
1 2 3 4 5 6
A
B
C
D
9 195 3 760 9 195
22 150
20 330
STOR
STOR
STOR
STOR
BATH
DW
KIT
TRASH
REF
DW
R
S
UP
S
R
DW
ENTRY
KIT
REF
DW
BATH
1 2 3 4 5 6
A
B
C
D
9 195 3 760 9 195
22 150
TERRACE TERRACE
BEDRM 2 LIVING
CLO
CLO
BEDRM 1 DINING
BEDRM 2LIVING
CLO
CLO
BEDRM 1DINING
1 1 1 1
STO STO
3 3
BEDRM 2 LIVING
BEDRM 1 DINING DINING BEDRM 1
LIVING BEDRM 2
CLO
CLO 11
1 1
CLO
CLO1 1
3 3
3 3
1 2
STAIR
RM
STO STO
3 3
1ST FLOOR PLAN
A5 HAZARDOUS MATERIALS REMOVAL PLAN - B125
NOT TO SCALE
2ND FLOOR PLAN
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
H
AZ
AR
D
O U
S M
AT
ER
IA
LS
R
EM
O
VA
L
PL
AN
BL
D
G
H-102
HAZARDOUS MATERIAL REMOVAL NOTES:
1. REFER TO SHEET H-101 FOR HAZARDOUS MATERIALS REMOVAL NOTES. NOTES ON SHEET H-101 APPLY TO ALL
HAZARDOUS MATERIALS REMOVAL WORK.
FLOORING VINYL TILE WITH GREY MASTIC 47 SM
ASBESTOS CONTAINING MATERIAL
ITEM ACM DESCRIPTION QUANTITYLOCATIONS
LEGEND
FLOORING VINYL SHEET WITH GREY MASTIC 176 SM2
GYPSUM BOARD WALL WITH SKIMCOAT / JOINT COMPOUND 505 SM3
"B", "C" AND "D", LIVING ROOM, DINING,
KITCHEN
ALL GYPSUM BOARD WALL
ALL CLOSETS, BUILDING ENTRANCE AND
"A" KITCHEN
STOR
STOR
BATH
DW
KIT
TRASH REF
DW
R
S
UP
S
R
DW
ENTRY
KIT
REF
DW
STO STO
BATH
1 2 3 4 5 6
A
B
C
D
9 195 3 760 9 195
22 150
BALCONY
DW
BALCONY
BATH
DW
KIT
REF
R
S
R
S
DW
KIT
REF
DN DW
STO STO
BATH
1 2 3 4 5 6
A
B
C
D
9 195 3 760 9 195
22 150
20 330
TERRACE TERRACE
BEDRM 2 LIVING
CLO
CLO
BEDRM 1 DINING
BEDRM 2LIVING
CLO
CLO
BEDRM 1DINING
1 1 1 1
BEDRM 2 LIVING
BEDRM 1 DINING DINING BEDRM 1
LIVING BEDRM 2
CLO
CLO 11
1 1
CLO
CLO1 1
STAIR
RM
1ST FLOOR PLAN
A5 HAZARDOUS MATERIALS REMOVAL PLAN - B291
NOT TO SCALE
2ND FLOOR PLAN
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
H
AZ
AR
D
O U
S M
AT
ER
IA
LS
R
EM
O
VA
L
PL
AN
BL
D
G
H-103
HAZARDOUS MATERIAL REMOVAL NOTES:
1. REFER TO SHEET H-101 FOR HAZARDOUS MATERIALS REMOVAL NOTES. NOTES ON SHEET H-101 APPLY TO ALL
HAZARDOUS MATERIALS REMOVAL WORK.
FLOORING VINYL TILE WITH GREY MASTIC 39 SM
ASBESTOS CONTAINING MATERIAL
ITEM ACM DESCRIPTION QUANTITYLOCATIONS
LEGEND
FLOORING VINYL SHEET WITH GREY MASTIC 176 SM2
"A", "B", "C" AND "D" LIVING ROOM, DINING,
KITCHEN
ALL CLOSETS AND BUILDING ENTRANCE
LIST OF ABBREVIATIONS
GENERAL CIVIL NOTES:
1. ALL WORK PERFORMED SHALL COMPLY WITH U.S. ARMY CORPS OF ENGINEERS EM
385-1-1, SAFETY AND HEALTH REQUIREMENTS, AND WITH ALL FEDERAL, STATE AND
LOCAL LAWS REQUIRED FOR THE PROTECTION OF PUBLIC HEALTH, SAFETY AND
ENVIRONMENTAL QUALITY. WHERE REQUIREMENTS VARY, THE MOST STRINGENT
REQUIREMENTS SHALL APPLY.
2. THE CONTRACTOR SHALL REMOVE ALL SILT AND DEBRIS RESULTING FROM HIS
WORK DEPOSITED IN DRAINAGE FACILITIES, ROADWAYS AND OTHER AREAS. THE
COSTS INCURRED FOR ANY NECESSARY REMEDIAL ACTION BY THE GOVERNMENT
SHALL BE PAYABLE BY THE CONTRACTOR.
3. THE CONTRACTOR SHALL RESTORE TO THEIR ORIGINAL CONDITION ALL
IMPROVEMENTS DAMAGED AS A RESULT OF THE CONSTRUCTION, INCLUDING
PAVEMENTS, EMBANKMENTS, CURBS, SIGNS, LANDSCAPING, STRUCTURES,
UTILITIES, WALLS, FENCES, ETC.
4. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL SIGNS, CONES, BARRICADES,
AND OTHER PROTECTIVE FACILITIES TO IDENTIFY AND DELINEATE CONSTRUCTION
WORK AREAS.
5. THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITIES AND STRUCTURES AS
SHOWN ON THE PLANS ARE BASED ON THE AVAILABLE DATA.
6. OBTAIN A BASE CIVIL ENGINEERING WORK CLEARANCE PRIOR TO THE START OF
CONSTRUCTION.
7. PRIOR TO COMMENCING EXCAVATION, NOTIFY THE CONTRACTING OFFICER.
8. IF CAVITIES AND/OR VOIDS ARE ENCOUNTERED DURING EXCAVATION WORK, STOP
WORK IMMEDIATELY AND NOTIFY THE CONTRACTING OFFICER.
9. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH 29 CFR 1910, NFPA 70
(NEC), NFPA 101 (LIFE SAFETY CODE), AND OTHER APPLICABLE INDUSTRY
STANDARDS RELATING TO OCCUPATIONAL SAFETY AND HEALTH.
10. AZIMUTHS MEASURED FROM TRUE NORTH = 0 DEGREES, 00 MINUTES, 00 SECONDS
AND INCREASE CLOCKWISE.
AC ASPHALT CONCRETE OR AIR CONDITIONING
ARCH ARCHITECTURAL
AS ASPHALT
BOT BOTTOM
C CENTER LINE
CONC, CO CONCRETE
CONT CONTINUOUS
CP CONCRETE PIPE
D DIAMETER OR DRAIN
DEFL DEFLECTION
DEG DEGREE
DI DRAIN INLET
DIA DIAMETER
DIP DUCTILE IRON PIPE
DMH STORM DRAIN MANHOLE
DWGS DRAWINGS
E,ELEC ELECTRICAL
EBOX ELECTRICAL BOX
ELEV ELEVATION
EMH ELECTRICAL MANHOLE
EP ELECTRIC POLE
EW EACH WAY
EXST, E/ EXISTING
FF FINISHED FLOOR
FG FINISHED GRADE
FH FIRE HYDRANT
H HEIGHT
HORIZ HORIZONTAL
INV INVERT
JGD JAPAN GEODETIC DATUM
JIS JAPANESE INDUSTRIAL STANDARDS
JWA JAPAN WATER WORKS ASSOCIATION
KG KILOGRAM
LP LIGHT POLE
DETAIL
NUMBER
IDENTIFICATION
NUMBER OF SHEET
ON WHICH SECTION
IS DRAWN
SECTION IDENTIFICATION
NUMBER
NUMBER OF SHEET
ON WHICH DETAIL
IS DRAWN
DETAIL1
SECTION1
OPEN DITCH
L-TYPE DITCH
GRATING
ELECTRIC POLEPOINT
GUARDRAIL
CONCRETE PAVEMENT
ASPHALT PAVEMENT
BUILDING
BLOCK WALL
ASPHALT BOUNDARY LINE
RETAINING WALL
OUTCROP
FENCE
KENCHI BLOCK
BANISTER
TURF AREA
WASTE LAND
HEDGE
SYMBOLS
TREES
VEGETATION BOUNDARY
LIGHT POLE
FIRE HYDRANT
EXISTING NEW
LCC
M METER
MAX MAXIMUM
ME MATCH EXISTING
MECH MECHANICAL
MH MANHOLE
MIN MINIMUM
mm MILLIMETER
N NUMBER
OC, O.C. ON CENTER
OD OUTSIDE DIAMETER
PAV'T, PVMT PAVEMENT
PT POINT
REQ'D REQUIRED
S SEWER OR SPREAD
SCH SCHEDULE
SD STORM DRAIN
SHT SHEET
SL SEWER LINE
SLP SLOPE
SM SQUARE METERS
SMH SEWER MANHOLE
STRUCT STRUCTURAL
SQ SQUARE
SST STAINLESS STEEL
STA STATION
T TELEPHONE
TBOX TELEPHONE BOX
TC TOP OF CONCRETE
THK THICK
TMH TELEPHONE MANHOLE
TP TELEPHONE POLE
TYP TYPICAL
VERT VERTICAL
W WATER
WL WATER LINE
WMH WATER MANHOLE
WV WATER VALVE
G
EN
ER
AL
C
IV
IL
N
O
TE
S, S
YM
BO
LS
A
N D
AB
BR
EV
IA
TI
O
N S
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
SLOPE
(WIRE = TENSION WIRE)
STONE FLAGGED DITCH
TELEPHONE LINE
WATER PIPE
SEWER PIPE
STORM DRAIN PIPE
TELEPHONE POLE
TRAFFIC SIGN
TELEPHONE MANHOLE
CONTROL POINT
SEWER MANHOLE
ELECTRIC MANHOLE
WATER MANHOLE
OVERHEAD ELECTRICAL LINE
CONCRETE PIPE
STORM DRAINAGE MANHOLE
ELECTRIC LINE
WATER VALVE
S
CLEANOUT
AIR RELIEF VALVE OR VALVE BOX
W
TO
PO
G R
AP
H
IC
S
U R
VE
Y
N O
TE
S
AN
D
L
IS
T O
F
TR
EE
S
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
TOPOGRAPHIC SURVEY NOTES:
1. TOPOGRAPHIC SURVEY COORDINATE SYSTEM IS THE JAPAN
GEODETIC DATUM (JGD) 2011, ZONE 10 AND IS IN INTERNATIONAL
METRIC UNITS.
2. THE "CONTROL POINTS SUMMARY TABLE" SHOWS THE
INFORMATION FOR THE BENCHMARKS ESTABLISHED AROUND THE
ENTIRE PERIMETER OF THE SITE IN MISAWA AIR BASE, JAPAN.
3. SURVEY CONDUCTED BY:
ENVIRONMENTAL SCIENCE CORPORATION
ESC BUILDNG 1553-231 ISHIKAWA IHA, URUMA CITY,
OKINAWA, 904-0012 JAPAN TEL. 011-81-098-989-0426
REGISTERED SURVEYOR: MR. KOJI CHINEN
JAPAN REGISTERED SURVEYOR, REGISTRATION NO: H7-724
4. DATE OF TOPOGRAPHIC SURVEY: DECEMBER 2021
5. LOCATION OF EXISTING MAINS AND SERVICE LATERAL LINES FOR
WATER, ELECTRICAL AND COMMUNICATION SYSTEMS SHOWN IN
THE SURVEY MAP ARE APPROXIMATE AND BASED ON BEST
AVAILABLE INFORMATION PROVIDED BY OTHERS.
E 44241.196
35.792
ELEVATION
MB4-2
MB4-1 76303.889
76404.181 44209.001
COORDINATES
N
34.253
No.
(BASED ON JGD 2011 ZONE 10 DATUM)
CONTROL POINTS SUMMARY TABLE
39.278M1 76353.996 44303.712
38.827M2 76391.410 44305.655
44426.309
45.560M4
M3 76672.029
76743.896 44431.713
46.507
8.00 6.00 0.451 SAKURA
9.00 7.00 0.502 SAKURA
8.00 6.00 0.403 SAKURA
9.00 7.00 0.454 SAKURA
9.00 7.00 0.505 SAKURA
8.00 6.00 0.456 SAKURA
11.00 6.00 0.457 SAKURA
0.458 SAKURA
16 MATUNOKI
17 SAKURA
18 SUGINOKI
9.00 7.00 0.459
0.3010
SAKURA
KEYAKI
10.00 5.00 0.40
10.00 6.00 0.60
10.00 5.00 0.30
8.00 7.00
7.00 4.00
8.00 5.00 0.4521 KEYAKI
11.00 5.00 0.4522 SUGINOKI
9.00 7.00 0.7023 SAKURA
10.00 6.00 0.3524 MATUNOKI
9.00 8.00 0.5025 SAKURA
KEYAKI
SUGINOKI
8.00 6.00 0.55
5.00 4.00 0.40
8.00 5.00 0.4011
12 SAKURA
13 SAKURA
14 SAKURA
9.00 6.00 0.4515 KEYAKI
8.00 7.00 0.40
9.00 6.00 0.35
9.00 7.00 0.45
KEYAKI
9.00 6.00 0.401 SAKURA
7.00 5.00 0.302 SAKURA
9.00 6.00 0.603 SAKURA
8.00 6.00 0.404 SAKURA
9.00 7.00 0.555 SAKURA
8.00 6.00 0.356 SAKURA
9.00 6.00 0.507 SAKURA
0.308 SAKURA
9.00 2.00 0.3011
12 SAKURA
13 SAKURA
14 SAKURA
7.00 6.00 0.4515 SAKURA
16 SAKURA
17 SAKURA
18 SAKURA
9.00 7.00 0.409
0.4010
SAKURA
SAKURA
8.00 7.00 0.35
7.00 5.00 0.35
8.00 6.00 0.45
8.00 6.00 0.50
9.00 7.00 0.50
9.00 5.00 0.40
9.00 6.00
9.00 7.00
8.00 6.00 0.3521 SAKURA
9.00 5.00 0.3522 SAKURA
8.00 5.00 0.4023 SAKURA
8.00 6.00 0.4024 SAKURA
9.00 7.00 0.6025 SAKURA
10.00 5.00 0.3031
32 SAKURA
33 SAKURA
34 SAKURA
9.00 6.00 0.5035 SAKURA
36 SAKURA
37 SAKURA
38 SAKURA
9.00 5.00 0.40
9.00 5.00 0.35
9.00 5.00 0.45
9.00 7.00 0.45
9.00 6.00 0.40
8.00 6.00 0.40
8.00 6.00 0.5041 SAKURA
9.00 5.00 0.5042 SAKURA
10.00 4.00 0.3543 SAKURA
8.00 6.00 0.4044 SAKURA
8.00 6.00 0.5045 SAKURA
8.00 5.00 0.3046 SAKURA
9.00 4.00 0.4047 SAKURA
0.3048 SAKURA
8.00 5.00 0.5051 SAKURA
53 SAKURA
54 SAKURA
11.00 4.00 0.3055
56 SAKURA
57 SAKURA
58 SUGINOKI
8.00 5.00 0.3049
0.4550
SAKURA
SAKURA
11.00 5.00 0.35
9.00 5.00 0.35
10.00 8.00 0.40
9.00 4.00 0.35
9.00 8.00 0.40
8.00 3.00 0.30
8.00 5.00
9.00 6.00
SAKURA
SAKURA
8.00 5.00 0.45
8.00 4.00 0.30
SAKURA
SAKURA
9.00 7.00 0.65
9.00 6.00 0.40
SUGINOKI
SAKURA
SUGINOKI
SUGINOKI
LIST OF TREES FOR B291
NO TREE SCIENTIFIC NAME H W D
LIST OF TREES FOR B123, B125, B127, B129
NO TREE SCIENTIFIC NAME H W D
9.00 6.00 0.3026 MATUNOKI
8.00 6.00 0.6027 SAKURA
0.4528 MATUNOKI
10.00 5.00 0.4029
0.4030
MATUNOKI
MATUNOKI
10.00 5.00
10.00 5.00
LIST OF TREES FOR B123, B125, B127, B129
NO TREE SCIENTIFIC NAME H W D
8.00 5.00 0.80SAKURA
8.00 4.00 0.3027 SAKURA
0.3528 SAKURA
9.00 6.00 0.4029
0.6030
SAKURA
SAKURA
9.00 5.00
9.00 7.00
C
IV
IL
E
XI
ST
IN
G
C O
N D
IT
IO
N S
PL
AN
B1
, B
5, B
7, B
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
CIVIL EXISTING CONDITIONS PLAN - B123, B125, B127, B129
GRAPHIC SCALE:
SCALE: 1:300
SCALE: 1:300
0 5 15m10
N O
R
TH
RRRRRRRR
STA M3
"+" CUT
ELEV = 46.507
STA M4
"+" CUT
ELEV = 45.560
CONTROL POINTS SUMMARY TABLE
(BASED ON JGD 2011 ZONE 10 DATUM)
COORDINATES
N E
ELEVATIONNo.
M3
M4
76672.029 44426.309
76743.896 44431.713
46.507
45.560
IL
E
XI
ST
IN
G
C O
N D
IT
IO
N S
PL
AN
B2
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
GRAPHIC SCALE:
SCALE: 1:300
0 5 15m10
N O
R
TH
RRRRRRRR
CIVIL EXISTING CONDITIONS PLAN - B291
SCALE: 1:300
STA M1
"+" CUT
ELEV = 39.278 STA M2
"+" CUT
ELEV = 38.827
STA MB4-2
"+" CUT
ELEV = 35.792
STA MB4-1
"+" CUT
ELEV = 34.253
CONTROL POINTS SUMMARY TABLE
(BASED ON JGD 2011 ZONE 10 DATUM)
COORDINATES
N E
ELEVATIONNo.
MB4-1
MB4-2
76303.889 44241.196
76404.181 44209.001
34.253
35.792
M1
M2
76353.996 44303.712
76391.410 44305.655
39.278
38.827
IL
D
EM
O
LI
TI
O N
P
LA
N
B1
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
CIVIL DEMOLITION PLAN - B123
GRAPHIC SCALE:
SCALE: 1:100 SCALE: 1:100
0 5m2.5
N O
R
TH
RRRRRRRR
EXST SMH 123-1
TOP = 46.68
INV IN = 45.99 (S100)
INV OUT = 45.93 (S200)
EXST SMH 123-2
TOP = 46.68
INV IN = 45.84 (S200)
INV IN = 45.44 (S100)
INV OUT = 45.41 (S200)
LP
DMH
DI
DIIDDIID
EXST TREE, TYP,
SEE SHEET C-002
TBOX
TVBOX
EBOX
83446
REMOVE APPROX
0.647M OF 100mm
SEWER LINELINE
REMOVE EXST CLEANOUT
TOP = 46.70
INV = 46.01
REMOVE APPROX 0.824M
OF 100mm SEWER LINE
REMOVE EXST CLEANOUT
TOP = 46.71
INV = 45.96
EXST PERCOLATION BASIN
S 2
S 2
SSSS
100 100 100000
SSSS
1000 100 10000
D 300000
EXST
TERRACE
EXST TERRACE
EXST FENCE, TYP
EXST ROOF
OVERHANG
NOTE:
CONTRACTOR MUST UNCOVER EXISTING UTILITY LINES AND
CONNECTION POINTS BEFORE STARTING UTILITY LINE WORK.
CONTACT 35 CES CONSTRUCTION MANAGER VIA THE CONTRACTING
OFFICER TO CONFIRM UTILITY LINE LAYOUTS AND CONNECTIONS.
REMOVE EXST PORCH AND
STAIRS, SEE ARCH DWGS
REMOVE APPROX 11.5 SM
OF EXST CONC WALKWAY
REMOVE APPROX 6.6 M OF
EXST CONC CURB, CONC
GUTTER TO REMAIN
EXST ROOF
LINE FOR CAR
PORT, TYP
wv wvww
46466644
REMOVE APPROX 2 SM
OF EXST CONC SIDEWALK
LP
REMOVE EXST TREE
EXST STORAGE ROOMS
EXST TRASH ENCLOSURE
REMOVE APPROX 1.2 M OF
EXST CONC CURB AND GUTTER
REMOVE APPROX 30 SM OF
EXST AC PAVEMENT
IL
D
EM
O
LI
TI
O N
P
LA
N
B1
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
CIVIL DEMOLITION PLAN - B125
GRAPHIC SCALE:
SCALE: 1:100 SCALE: 1:100
0 5m2.5
N O
R
TH
RRRRRRRR
EXST SMH 125-2
TOP = 45.06
INV IN = 42.55 (S200)
INV IN = 42.58 (S100)
INV OUT = 42.54 (S200)
EXST SMH 125-1
TOP = 44.93
INV IN = 42.59 (S200)
INV IN = 42.60 (S100)
INV OUT = 42.58 (S200)
LP
DMH
DI
DIIDDIID
DMH
DI
wv wv
DI
TBOX
TVBOXBOT
EBOX
EBOXXEB
83446 125
REMOVE
APPROX 7.581M
OF 100mm
SEWER LINE
REMOVE EXST
CLEANOUT
TOP = 45.45
INV = 44.66
REMOVE APPROX
6.199M OF 100mm
SEWER LINE
REMOVE EXST
CLEANOUT
TOP = 45.44
INV = 44.65 EXST PERCOLATION BASIN
DECONSTRUCT FENCE TO
NEAREST POST OR GATE
FOR ACCESS AND SET ASIDE
FOR REUSE. REASSEMBLE
WHEN COMPLETE, TYP OF 2
S
S
SSSS 1
000001
SSS 1
0000001
S
D
D 2 00000
D
3000 DD
300303
EXST FENCE, TYP
EXST TERRACE
EXST
TERRACE
EXST ROOF
OVERHANG
NOTE:
REMOVE EXST PORCH AND
STAIRS, SEE ARCH DWGS
REMOVE APPROX 18.0 SMRE
OF EXST CONC WALKWAY
EXST ROOF LINE
FOR CAR PORT, TYP
D
D
REMOVE APPROX 1 M OF
CONC CURB AND GUTTER
REMOVE APPROX 23 SM
OF AC PAVEMENT
REMOVE APPROX 1 M OF
CONC CURB AND GUTTER
REMOVE APPROX 2 SM
OF CONC SIDEWALK
D 3
DMH
DI
DI
EBOX
DI
D 2
D 2 000000
EXST TREE, TYP,
SEE SHEET C-002
EXST STORAGE ROOMS
EXST TRASH ENCLOSURE
CONTRACTOR MUST UNCOVER EXISTING
UTILITY LINES AND CONNECTION POINTS
BEFORE STARTING UTILITY LINE WORK.
CONTACT 35 CES CONSTRUCTION
MANAGER VIA THE CONTRACTING
OFFICER TO CONFIRM UTILITY LINE
LAYOUTS AND CONNECTIONS.
IL
D
EM
O
LI
TI
O N
P
LA
N
B1
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
CIVIL DEMOLITION PLAN - B127
SCALE: 1:100
N O
R
TH
RRRRRRRR
4544544
TBOXOXT TVBOXOXTV
EBOX
WV
WV
DI
DMH
LP
DI
DI
EBOXBO
DI
DMH
TMH
REMOVE APPROX 0.979M
OF 100mm SEWER LINE
REMOVE EXST
CLEANOUT
TOP = 44.99
INV = 44.20
EXST PERCOLATION BASIN
REMOVE EXST
CLEANOUT
TOP = 44.99
INV = 44.20
S
SS
SS
SSS 10
0000000001
SSSS 10
0000001
REMOVE APPROX
0.915M OF 100mm
SEWER LINE
1010101111
D 20000
DDD 2
0022020
D
EXST SMH 127-2
TOP = 44.98
INV IN = 42.95 (S200)
INV IN = 42.94 (S100)
INV OUT= 42.94 (S200)
EXST SMH S127-1
TOP = 44.97
INV IN = 43.14 (S200)
INV OUT= 43.10 S(200)
834478
EXST TERRACE
EXST
TERRACE
EXST FENCE, TYP
EXST ROOF
OVERHANG
GRAPHIC SCALE:
SCALE: 1:100
0 5m2.5
NOTE:
REMOVE EXST PORCH AND
STAIRS, SEE ARCH DWGS
REMOVE APPROX 17.2 SM
OF EXST CONC WALKWAY
EXST ROOF LINE
FOR CAR PORT, TYP
EXST TREE, TYP,
SEE SHEET C-002
REMOVE EXST TREE
EXST STORAGE ROOMS
EXST TRASH ENCLOSURE
CONTRACTOR MUST UNCOVER EXISTING UTILITY LINES AND
CONNECTION POINTS BEFORE STARTING UTILITY LINE WORK.
CONTACT 35 CES CONSTRUCTION MANAGER VIA THE CONTRACTING
OFFICER TO CONFIRM UTILITY LINE LAYOUTS AND CONNECTIONS.
IL
D
EM
O
LI
TI
O N
P
LA
N
B1
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
CIVIL DEMOLITION PLAN - B129
SCALE: 1:100
N O
R
TH
RRRRRRRR
4544544
834488
DMH
LP
DI
DI
WVV
TBOXTBO
TVBOXVB
EBOXB
EBOX
DI
DMH
REMOVE APPROX 0.850M
OF 100mm SEWER LINE
REMOVE EXST
CLEANOUT
TOP = 45.36
INV = 44.63
EXST PERCOLATION BASINS
REMOVE EXST
CLEANOUT
TOP = 45.35
INV = 44.63
REMOVE APPROX 0.695M
OF 100mm SEWER LINE
SS 200
S 2000
SSS
10000100000
SSSSS
100001100000000000000000000000000000000000000
D 20000
DD 2
0022020
D
EXST SMH 129-2
TOP = 45.28
INV IN = 43.67 (S100)
INV IN = 44.45 (S200)
INV OUT= 43.63 (S200)
EXST SMH 129-1
TOP = 45.30
INV IN = 44.56 (S100)
INV OUT= 44.55 (S200)
EXST FENCE, TYP
EXST TERRACE
EXST TERRACE
EXST ROOF OVERHANG
WV
GRAPHIC SCALE:
SCALE: 1:100
0 5m2.5
NOTE:
REMOVE EXST PORCH AND STAIRS,
SEE ARCH DWGS
REMOVE APPROX 17.2 SM
OF EXST CONC WALKWAY
EXST ROOF LINE
FOR CAR PORT, TYP
EXST TREE, TYP,
SEE SHEET C-002
REMOVE EXST TREEE
REMOVE EXST FIRE HYDRANT TO HYDRANT
ELBOW BELOW EXST GROUND AND PROVIDE
150mm BLIND FLANGE. SET ASIDE EXST FIRE
HYDRANT AND HYDRANT ELBOW FOR REUSE.
FH
WV SIGNPOSTPO
DI
DI
DI
DMH
EXST WATER LINE
WW
W
EXST STORAGE ROOMS
EXST TRASH ENCLOSURE
CONTRACTOR MUST UNCOVER EXISTING UTILITY LINES AND
CONNECTION POINTS BEFORE STARTING UTILITY LINE WORK.
CONTACT 35 CES CONSTRUCTION MANAGER VIA THE CONTRACTING
OFFICER TO CONFIRM UTILITY LINE LAYOUTS AND CONNECTIONS.
IL
D
EM
O
LI
TI
O N
P
LA
N
B2
PR
O
JE
C
T Q
K K
A
-4
R
EP
A
IR
J
N C
O H
O M
ES
, M
FH
, 1
, 1
, 1
, 2
M
IS
A
W A
, J A
PA
N
U .S
. A
IR
F O
R C
E M
IS
A
W A
A
IR
B A
SE
, J
A
C
IV
IL
E
N G
IN
EE
R S
Q U
A D
R O
N
H D
R E
N G
IN
EE
R
IN
G , I
N C
B
IS
H
O P
ST
R
EE
T, S U
IT
E
0, H O
N O
LU
LU
, H A
W A
II
GRAPHIC SCALE:
SCALE: 1:100
0 2.5 5m
N O
R
TH
CIVIL DEMOLITION PLAN - B291
SCALE: 1:100
EXST SMH 291-1
TOP = 37.54
INV IN = 36.51 (S100)
INV OUT= 36.49 (S200)
EXST SMH 291-2
TOP = 37.52
INV IN = 34.95 (S100)
INV OUT= 34.76 (S200)
TMH
SMH
WV
WV
WV
38 SMH
WV
VENT
VENT
EXST TREE, TYP,
SEE SHEET C-002
REMOVE APPROX 2.834M
OF 100mm SEWER LINE
REMOVE EXST CLEANOUT
TOP = 37.58
INV = 36.81
REMOVE APPROX 2.760M
OF 100mm SEWER LINE
REMOVE EXST
CLEANOUT
TOP = 37.53
INV = 36.80
EXST PERCOLATION BASIN
EXST HOT
WATER VAULT
S 2
S
S 200
S
S
S 10 0 S 10
S
S
S
D 600
DECONSTRUCT FENCE TO NEAREST POST OR
GATE FOR ACCESS AND SET ASIDE FOR REUSE.
REASSEMBLE WHEN COMPLETE, TYP OF 2
IN = 36.41 (VP200)
IN = 34.79 (CP200)
IN = 36.38 (VP200)
IN = 34.83 (CP200)
EXST TERRACE
EXST
TERRACE
EXST FENCE, TYP
EXST ROOF
OVERHANG
REMOVE APPROX 7.0 SM
OF EXST CONC WALKWAY
R…