6.1.5.1 100P Design Drawing Set - Mountain Home Chapel Kitchen Renovation2.pdf

PDF 10 MB Posted

Attached to
Renovate Base Chapel
Solicitation number
FA489726Q0025
Issued by

About this file

This is a comprehensive set of architectural and engineering construction documents for the Chapel Kitchen Renovation at Facility 2606, Mountain Home Air Force Base, Idaho, under contract FA4897-19-C-A016. The project involves renovation of a kitchen facility (Room 101) with adjacent multi-purpose room (102), storage (103), and mechanical space (104).

The architectural scope includes new wall and ceiling construction with detailed finishes, door assemblies, window treatments, and cabinetry. The mechanical systems encompass HVAC modifications including removal of existing packaged unit components, installation of new supply/return ductwork with balancing dampers, two range hoods (RH-1, RH-1) operating at variable speeds, an exhaust fan (EF-1) with CO2 sensor controls, and combustion air/exhaust systems for the water heater. Fire dampers must be installed in existing ductwork above ceilings. The plumbing work includes extending domestic cold water and hot water lines, installing a 3-compartment sink with garbage disposal, grease interceptor, new water heater, recirculation pump, ice maker outlet, and drain extensions with proper venting through the roof. Natural gas service includes a solenoid shut-off valve controlled by fire alarm or manual switch. Electrical systems provide new panelboard (Panel D) with 100-amp service, lighting fixtures throughout (LED 2'x4' grid and down lights), GFCI receptacles, controls for mechanical equipment, and fire alarm integration. Fire alarm systems include replacement of pull stations, heat detectors, and door holders, with new NAC booster panel, smoke detectors, and notification devices. All work must comply with current building codes including IBC, IFC, NFPA 72, and NEC standards. Construction documentation was finalized in March 2020 with 31 sheets of plans and specifications.

View the file

Other files

File Type Posted
Solicitation Amendment FA489726Q00250009 SF 30.pdf PDF
Solicitation - FA489726Q00250009.pdf PDF
Solicitation - FA489726Q00250008.pdf PDF
Solicitation Amendment FA489726Q00250008 SF 30.pdf PDF
Solicitation Amendment FA489726Q00250007 SF 30.pdf PDF
Solicitation - FA489726Q00250007.pdf PDF
Solicitation Amendment FA489726Q00250006 SF 30.pdf PDF
QA_FA489726Q0025 Renovate Base Chapel (002).pdf PDF
Solicitation SF1442 - FA489726Q00250005.pdf PDF
Solicitation Amendment FA489726Q00250005 SF 30.pdf PDF
Site Visit Attendance.pdf PDF
Solicitation - FA489726Q00250005.pdf PDF
Chapel Second Site Visit Attendee List.pdf PDF
Solicitation Amendment FA489726Q00250004 SF 30.pdf PDF
Solicitation - FA489726Q00250004.pdf PDF
Solicitation Amendment FA489726Q00250003 SF 30.pdf PDF
Solicitation Amendment FA489726Q00250002 SF 30 (1).pdf PDF
FA489726Q00250001 SF 30 Solicitation Amendment 1.pdf PDF
6.2.2. Specifications_B2606 Fire Alarm Repair.pdf PDF
Solicitation - FA489726Q0025.pdf PDF
6.2.1. Drawings_B2606 Fire Alarm Repair.pdf PDF
SOW_Renovate Base Chapel_B2606.pdf PDF
6.3.1.Base Design Guide Data Sheet-MHAFB DESIGN STANDARDS 2026.pdf PDF
6.1.5. 100 Design Drawing Set - Mountain Home Chapel Kitchen Renovation1.pdf PDF
6.2.3.DA_B2606 Fire Alarm Repair.pdf PDF
DBA ID20260020 05182026.pdf PDF
6.4.1.Specs Intact file - 4.2_01 57 19_MHAFB Env Spec 20220614.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Mike Perez Text Box

LEGEND OF MECHANICAL SYMBOLS AND ABBREVIATIONS

MECHANICAL

SYMBOLS

M E

C H

A N

I C

A L

S

Y M

B O

E G

E N

D

D

G

E N

E R

O T

E S

M-000

181 East 5600 South

Murray, Utah 84107

O: (801) 530-3148

F: (801) 530-3150 www.vbfa.com vbfa project #: 19540

C O

N T

R A

C T

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

U M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L

A

L E

P

L O

T

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

C

E S

C

E N

M O

U N

T A

I

H

M

E

A

R

F

R

B

S

E

7654321

A N

S I

D

N

O V

E M

B E

R

T

E D

W

A

K

E

C

I T

Y

U

T

SHEET OF 31

F A

C

A

C H

A P

E L

K

I T

C H

N

O V

A T

I O

N

F

A C

I L I T

Y

M O

U N

T A

M

E

A

R

S

E

I D

A H

O

L

IC

EN

SE

D P

ROFESS I ONAL ENG

IN

E

ER

No. 354088

S TAT E O F U TAH

JAMES E.

NIGHTINGALE

GENERAL NOTES

MECHANICALGENERAL NOTES

AutoCAD SHX Text W

AutoCAD SHX Text R

AutoCAD SHX Text 12/12

AutoCAD SHX Text

FD

AutoCAD SHX Text 8/8

AutoCAD SHX Text

FIRE DAMPER IN DUCT, W/ ACCESS PANEL REQD.

AutoCAD SHX Text

MANUAL VOLUME DAMPER

AutoCAD SHX Text

RECTANGULAR TO ROUND DUCT TRANSFORMATION

AutoCAD SHX Text RECTANGULAR TO RECTANGULAR OR ROUND TO ROUND DUCT TRANSFORMATION MAXIMUM 15° INCLUDED ANGLEEXCEPT WHERE SHOWN OTHERWISE.

AutoCAD SHX Text

R/W=1. ROUND DUCT SIMILAR TO RECTANGULAR

AutoCAD SHX Text

INCLINED DROP

AutoCAD SHX Text

INCLINED RISE

AutoCAD SHX Text

WITH RESPECT TO AIR FLOW 15°NOMINAL INCLINE WITH RADIUS TURNS=DEPTH OF DUCT.

AutoCAD SHX Text

ROUND DUCT WITH NET INSIDE DIMENSIONS SHOWN IN INCHES.

AutoCAD SHX Text

RECTANGULAR DUCT WITH NET INSIDE DIMENSIONS SHOWN IN INCHES.

AutoCAD SHX Text

CEILING AIR GRILLE WITH FLEXIBLE DUCT

AutoCAD SHX Text

CEILING SUPPLY DIFFUSER WITH FLEXIBLE DUCT

AutoCAD SHX Text

SIDEWALL EXHAUST OR RETURN REGISTER

AutoCAD SHX Text

SIDEWALL SUPPLY REGISTER

AutoCAD SHX Text

CEILING EXHAUST REGISTER, (BALANCE TO MATCH SUPPLY IF RETURN CFM IS NOT SHOWN)

AutoCAD SHX Text

CEILING RETURN REGISTER

AutoCAD SHX Text

CEILING SUPPLY DIFFUSER

AutoCAD SHX Text

TURNING VANES

AutoCAD SHX Text

ROUND DUCT - DROP

AutoCAD SHX Text

ROUND DUCT - RISE

AutoCAD SHX Text

NEGATIVE PRESSURE DUCT - DROP

AutoCAD SHX Text 12/8

AutoCAD SHX Text 12%%c

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text 12/12

AutoCAD SHX Text 12%%c

AutoCAD SHX Text

KEYED NOTE IDENTIFICATION

AutoCAD SHX Text

AutoCAD SHX Text

POSITIVE PRESSURE DUCT - RISE

AutoCAD SHX Text

POSITIVE PRESSURE DUCT - DROP

AutoCAD SHX Text

NEGATIVE PRESSURE DUCT - RISE

AutoCAD SHX Text

12/8 FO

AutoCAD SHX Text

FLAT OVAL DUCT WITH NET INSIDE DIMENSIONS SHOWN IN INCHES.

AutoCAD SHX Text

POINT OF CONNECTION

AutoCAD SHX Text 19540_M-000.dwg

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text

M. POND

AutoCAD SHX Text

J. NIGHTINGA

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text 03/12/2020

AutoCAD SHX Text

1. NEW DUCTWORK, PIPING AND EQUIPMENT SHALL BE NEW DUCTWORK, PIPING AND EQUIPMENT SHALL BE COORDINATED WITH STRUCTURE, LIGHTS, REFLECTED CEILING PLANS, ELECTRICAL CONDUIT, PLUMBING, MECHANICAL AND FIRE PROTECTION PIPING, AUDIO/VISUAL SYSTEMS, ALL OTHER TRADES AND ALL OTHER EXISTING CONDITIONS. 2. NOT ALL INFORMATION IS SHOWN ON THE HVAC NOT ALL INFORMATION IS SHOWN ON THE HVAC DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING INFORMATION ON ALL OTHER CONSTRUCTION DOCUMENTS. THE CONTRACTOR WILL BE FAMILIAR WITH THE DRAWINGS, SPECIFICATIONS, AND ADDENDUMS. 3. THE WORKING DRAWINGS ARE DIAGRAMMATIC (DRAWINGS THE WORKING DRAWINGS ARE DIAGRAMMATIC (DRAWINGS ARE NOT TO BE SCALED). BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, THEY DO NOT SHOW EVERY OFFSET, BEND OR ELBOW NECESSARY FOR THE COMPLETE INSTALLATION IN THE SPACE PROVIDED. ALL LOCATIONS FOR HVAC EQUIPMENT SHALL BE CHECKED AND COORDINATED WITH THE DRAWINGS. 4. THE DRAWINGS AND SPECIFICATION HAVE BEEN THE DRAWINGS AND SPECIFICATION HAVE BEEN PREPARED TO SUPPLEMENT EACH OTHER AND THEY SHALL BE INTERPRETED AS AN INTEGRAL UNIT WITH THE ITEMS SHOWN ON ONE AND NOT THE OTHER BEING FURNISHED AND INSTALLED AS THOUGH SHOWN AND CALLED OUT IN BOTH. 5. ANY PART OF THIS INSTALLATION THAT FAILS, IS UNFIT, ANY PART OF THIS INSTALLATION THAT FAILS, IS UNFIT, OR BECOMES DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 6. THE CONTRACTOR IS RESPONSIBLE FOR ALL EQUIPMENT THE CONTRACTOR IS RESPONSIBLE FOR ALL EQUIPMENT (INCLUDED IN THIS BID) CHECK-IN, SAFEKEEPING, AND DAMAGE. 7. IF FOR ANY REASON THE ROUTING OF PIPE OR IF FOR ANY REASON THE ROUTING OF PIPE OR DUCTWORK DEVIATED FROM THAT SHOWN ON THE DRAWING THE GENERAL AND MECHANICAL CONTRACTOR AND OR TIER SUBS SHALL BE RESPONSIBLE FOR ANY ADDITIONAL COST RELATED TO EXTRA HANGERS. 8. ALL MATERIALS LOCATED ABOVE CEILING ARE TO BE ALL MATERIALS LOCATED ABOVE CEILING ARE TO BE RATED FOR PLENUM INSTALLATION, TYPICAL. 9. GENERAL MECHANICAL CONTRACTOR TO PROVIDE GENERAL MECHANICAL CONTRACTOR TO PROVIDE BACKING FOR EQUIPMENT AS REQUIRED. 10. DUCTWORK DIFFUSERS, REGISTERS OR GRILLES, DUCTWORK DIFFUSERS, REGISTERS OR GRILLES, EQUIPMENT ETC. SHOWN WITH X'S SHALL BE DEMOLISHED, TYPICAL. 11. THE LOCATION AND ROUTING OF ALL EXISTING THE LOCATION AND ROUTING OF ALL EXISTING DUCTWORK, EQUIPMENT AND PIPING (INCLUDING ALL BELOW FLOOR PIPING), IS ONLY APPROXIMATE AND IS SCHEMATIC IN NATURE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE EXACT LOCATION OF ALL EXISTING SYSTEMS AND CONDITIONS. 12. DUCTWORK, DIFFUSERS, GRILLES, EQUIPMENT, ETC. DUCTWORK, DIFFUSERS, GRILLES, EQUIPMENT, ETC. SHOWN LIGHT SHALL REMAIN, TYPICAL. 13. SHEET METAL CONTRACTOR SHALL TAKE CARE TO SHEET METAL CONTRACTOR SHALL TAKE CARE TO ENSURE THAT ALL DUCTWORK OPENINGS REMAIN FREE OF DEBRIS, TYPICAL.

AutoCAD SHX Text

1. FLEXIBLE DUCT MAXIMUM LENGTH IS 5'-0", EXCEPT FLEXIBLE DUCT MAXIMUM LENGTH IS 5'-0", EXCEPT AS NOTED. SUPPORT AS REQUIRED TO AVOID "KINKS", TYPICAL. 2. PROVIDE BALANCING DAMPER AT ALL BRANCH DUCTS PROVIDE BALANCING DAMPER AT ALL BRANCH DUCTS SERVING SINGLE DIFFUSER, REGISTER OR GRILLE, TYPICAL. 3. COORDINATE EXACT PLACEMENT OF DIFFUSERS, COORDINATE EXACT PLACEMENT OF DIFFUSERS, GRILLES AND REGISTERS WITH ARCHITECTURAL REFLECTED CEILING PLAN, TYPICAL. 4. SEE DETAIL FOR DIFFUSER CONNECTIONS TO SEE DETAIL FOR DIFFUSER CONNECTIONS TO DUCTWORK, TYPICAL. 5. BRANCH DUCTWORK SHALL BE SIZED TO MATCH THE BRANCH DUCTWORK SHALL BE SIZED TO MATCH THE NECK SIZE OF THE DIFFUSERS, REGISTER OR GRILLE IT SERVES UNLESS NOTED OTHERWISE, TYPICAL. 6. COORDINATE MOUNTING LOCATION OF THERMOSTAT COORDINATE MOUNTING LOCATION OF THERMOSTAT WITH ARCHITECTURAL FURNISHINGS, TYPICAL. 7. COORDINATE EXACT LOCATION OF DUCTWORK WITH COORDINATE EXACT LOCATION OF DUCTWORK WITH STRUCTURAL MEMBERS, LIGHTS, REFLECTED CEILING, PLUMBING, MECHANICAL PIPING, FIRE PROTECTION, AND OTHER TRADES, TYPICAL. 8. INSTALL TURNING VANES IN ALL SQUARE LOW INSTALL TURNING VANES IN ALL SQUARE LOW PRESSURE DUCTWORK AT ELBOWS OR TEES, TYPICAL. 9. FIELD VERIFY THE FIT OF ALL DUCTWORK BEFORE FIELD VERIFY THE FIT OF ALL DUCTWORK BEFORE FABRICATION, TYPICAL. 10. CONTRACTOR SHALL OFF-SET DUCTWORK AS CONTRACTOR SHALL OFF-SET DUCTWORK AS REQUIRED WHERE STRUCTURE, LIGHTING OR PIPING CONFLICTS EXIST, TYPICAL. 11. DUCTWORK SIZES ARE FREE AREA SIZES, TYPICAL. DUCTWORK SIZES ARE FREE AREA SIZES, TYPICAL. 12. IN HARD CEILING AREAS, INSTALL REMOTE DAMPER IN HARD CEILING AREAS, INSTALL REMOTE DAMPER OPERATOR IN CEILING, SEE SPECIFICATION, TYPICAL.

Mike Perez

EXISTING

PACKAGED

UNIT

M E

C H

A N

I C

M

O L

I T

I O

N

F

L O

P

A

N

MD-101

8'0 4' 16'

KEY NOTES

VERIFY BALANCING DAMPERS EXIST IN ALL DUCT

BRANCHES AND INSTALL NEW IF ANY ARE MISSING.

EXISTING HOOD OVER OUTSIDE AIR INLET TO BE

REMOVED AND INLET EXTENDED UNDER NEW

CONSTRUCTION PHASE.

DEMOLISH ALL GRILLES, REGISTERS, AND DIFFUSERS

WHEN ARCHIECTURAL CEILING TILES ARE REMOVED.

MECHANICAL DEMOLITION FLOOR PLAN

181 East 5600 South

Murray, Utah 84107

O: (801) 530-3148

F: (801) 530-3150 www.vbfa.com vbfa project #: 19540

C O

N T

R A

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L

A

L E

P

L O

T

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

C

E S

C

E N

M O

U N

T A

M

E

A

R

S

E

7654321

A N

S I

D

N

O V

E M

B E

R

T

E D

A

K

E

C

I T

Y

U

T

SHEET OF 31

F A

C

A

C H

A P

E L

K

I T

C H

N

O V

A T

I O

N

F

A C

I L I T

Y

M O

U N

T A

M

E

A

R

S

E

I D

A H

O

L

IC

EN

SE

D P

ROFESS I ONAL ENG

IN

E

ER

No. 354088

S TAT E O F U TAH

JAMES E.

NIGHTINGALE

AutoCAD SHX Text 19540_MD-101.dwg

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text

M. POND

AutoCAD SHX Text

J. NIGHTINGA

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text N

AutoCAD SHX Text

SCALE: 3/16"=1'-0"

AutoCAD SHX Text 03/12/2020

Mike Perez

ATC

G-1 16x16

1000 CFM

(TYP 3)

D-1 8"Ø

250 CFM

(TYP 12)

D-1 8"Ø

250 CFM

(TYP 4)

8"Ø TO

WALL CAP

R x

C

F M

S

CO2

MD

14x12"

EXISTING

PACKAGED

UNIT

EF

RH

RH

FD

FD FD

M E

C H

A N

I C

O

A

N

M-101

8'0 4' 16'

KEY NOTES

PERFORM AIR BALANCE SURVEY OF ALL EXISTING

DIFFUSERS, REGISTERS, GRILLES, AND EXISTING

PACKAGED UNIT PRIOR TO ANY DEMOLITION / WORK

BEGINNING AND PROVIDE REPORT. REPLACE

EXISTING DIFFUSERS, REGISTERS, GRILLES AND

COORDINATE LOCATION WITHIN NEW CEILING GRID.

RECONNECT TO EXISTING DUCT BRANCH AND

BALANCE TO CFM SHOWN.

3" COMBUSTION AIR INTAKE AND EXHAUST SERVING

WATER HEATER TO DISCHARGE THRU WALL WITH

MANUFACTURER PROVIDED CONCENTRIC VENT KIT.

FAN CONTROLLER, COORDINATE LOCATION WITH

STORAGE ROOM SHELVING. PROVIDED AND

INSTALLED BY JOHNSON CONTROLS.

CO2 SENSOR FOR CONTROL OF EF-1. EXHAUST FAN

TO SERVE AS REMOTE POWERED EXHAUST FOR

EXISTING PACKAGING UNIT. CO2 SENSOR TO

ENERGIZE FAN WHEN CO2 RISES TO 800 PPM IN

DINING AREA. IT IS ASSUMED THE ROLL-UP WINDOW

BETWEEN THE DINING AREA AND THE KITCHEN IS UP

WHEN THE DINING AREA IS DENSELY OCCUPIED.

SATURATED ROOM AIR FROM DINING AREA IS DRAWN

ACROSS KITCHEN AND OUT THE RANGE HOOD(S) OR

THE EXHAUST, EF-1.

REMOVE OUTSIDE AIR (OA) HOOD FROM EXISTING

PACKAGED UNIT AND REPLACE WITH NEW PLENUM

FULL SIZE OF OA OPENING. EXTEND 24x24 OA DUCT

OVER TO, AND UP BUILDING WALL TERMINATING WITH

A GOOSENECK FITTING WITH BOTTOM OF OPENING AT

MIN. 10 FT. ABOVE FINISHED GRADE.

HVAC SHUTDOWN SWITCH. INTERLOCK WITH EXISTING

PACKAGED UNIT, RANGE HOODS, AND EXHAUST FAN.

ATC DAMPER TO OPEN & CLOSE BASED ON EXHAUST

FANS OPERATION. CONTRACTOR TO SET CLOSED

POSITION OF DAMPER TO ALLOW 2,000 CFM OF

RETURN AIR TO THE EXISTING PACKAGED UNIT.

CLOSE WHEN EF-1 AND RANGE HOODS RH-1 ARE

RUNNING. CLOSED POSITION ENABLES FLOW

BALANCE TO EXHAUST FAN, EF-1. PROVIDE ACCESS

DOOR IN DUCT FOR MAINTENANCE.

THIS AREA RESERVED FOR FIRE PROTECTION

STANDPIPE AND CONTROLS.

INSTALL NEW FIRE DAMPER IN EXISTING DUCTWORK

ABOVE CEILINGS AS FIRE RATING EXTENDS TO ROOF

DECK. 3 PLACES. PROVIDE NEW ACCESS DOORS AT

DUCT FOR DAMPER MAINTENANCE ABOVE DINING

AREA LAY-IN CEILING.

MOTORIZED DAMPER TO BE NORMALLY CLOSED

WHEN FAN IS DE-ENERGIZED. OPEN ONLY WHEN FAN

IS ENERGIZED.

CONTRACTOR TO PROVIDE AND INSTALL NEW

GRILLES, REGISTERS, AND DIFFUSERS. SEE

SCHEDULES FOR DETAILS. SUPPORT ANY FLEX DUCT

TRANSITIONS PER MECHANICAL DETAILS.

MECHANICAL FLOOR PLAN

181 East 5600 South

Murray, Utah 84107

O: (801) 530-3148

F: (801) 530-3150 www.vbfa.com vbfa project #: 19540

C O

N T

R A

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L

A

L E

P

L O

T

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

C

E S

C

E N

M O

U N

T A

M

E

A

R

S

E

7654321

A N

S I

D

N

O V

E M

B E

R

T

E D

A

K

E

C

I T

Y

U

T

SHEET OF 31

F A

C

A

C H

A P

E L

K

I T

C H

N

O V

A T

I O

N

F

A C

I L I T

Y

M O

U N

T A

M

E

A

R

S

E

I D

A H

O

L

IC

EN

SE

D P

ROFESS I ONAL ENG

IN

E

ER

No. 354088

S TAT E O F U TAH

JAMES E.

NIGHTINGALE

AutoCAD SHX Text 19540_M-101.dwg

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text

M. POND

AutoCAD SHX Text

J. NIGHTINGA

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text N

AutoCAD SHX Text

SCALE: 3/16"=1'-0"

AutoCAD SHX Text 03/12/2020

Mike Perez

M

C H

A N

I C

T

A I L

S

M-501

181 East 5600 South

Murray, Utah 84107

O: (801) 530-3148

F: (801) 530-3150 www.vbfa.com vbfa project #: 19540

C O

N T

R A

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L

A

L E

P

L O

T

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

C

E S

C

E N

M O

U N

T A

M

E

A

R

S

E

7654321

A N

S I

D

N

O V

E M

B E

R

T

E D

A

K

E

C

I T

Y

U

T

SHEET OF 31

F A

C

A

C H

A P

E L

K

I T

C H

N

O V

A T

I O

N

F

A C

I L I T

Y

M O

U N

T A

M

E

A

R

S

E

I D

A H

O

L

IC

EN

SE

D P

ROFESS I ONAL ENG

IN

E

ER

No. 354088

S TA T E O F U TAH

JAMES E.

NIGHTINGALE

AutoCAD SHX Text 19540_M-501.dwg

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text

M. POND

AutoCAD SHX Text

J. NIGHTINGA

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text 03/12/2020

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text L

AutoCAD SHX Text M-501

AutoCAD SHX Text

AutoCAD SHX Text

BRANCH DUCT TAKE-OFF & DAMPER DETAIL

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text NOTE: DAMPERS SHOULD NOT BE INSTALLED CLOSER THAN TWO DUCT WIDTHS TO ELBOWS OR INTERSECTIONS.

AutoCAD SHX Text

REMOTE CEILING OPERATOR WHERE DAMPER IS INACCESIBLE

AutoCAD SHX Text

NOTE L=1/4 W (4" MIN.)

AutoCAD SHX Text

VOLUME DAMPER PROVIDE CONCEALED CEILING DAMPER REGULATOR

AutoCAD SHX Text W

AutoCAD SHX Text 45%%D

AutoCAD SHX Text %%u45%%D Y TEE

AutoCAD SHX Text %%u2-WAY 45%%D Y

AutoCAD SHX Text %%u90%%D ELONGATED TEE

AutoCAD SHX Text %%u90%%D CONICAL TEE

AutoCAD SHX Text

BRANCH DUCT

AutoCAD SHX Text

BRANCH DUCT

AutoCAD SHX Text

BRANCH DUCT

AutoCAD SHX Text

BRANCH DUCT

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text M-501

AutoCAD SHX Text

AutoCAD SHX Text

ROUND DUCT BRANCH TAKE-OFF DETAILS

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

TRUNK DUCT

AutoCAD SHX Text

BRANCH DUCT

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

TRUNK DUCT

AutoCAD SHX Text

TRUNK DUCT

AutoCAD SHX Text

TRUNK DUCT

AutoCAD SHX Text 11.25%%D

AutoCAD SHX Text 22.5%%D

AutoCAD SHX Text 11.25%%D

AutoCAD SHX Text 15%%D

AutoCAD SHX Text 15%%D

AutoCAD SHX Text 20%%D

AutoCAD SHX Text 20%%D

AutoCAD SHX Text 10%%D

AutoCAD SHX Text 10%%D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text

(MIN.)

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text

(MIN.)

AutoCAD SHX Text

(MIN.)

AutoCAD SHX Text

(MIN.)

AutoCAD SHX Text

(MIN.)

AutoCAD SHX Text M-501

AutoCAD SHX Text

AutoCAD SHX Text

ROUND DUCT ELBOW DETAILS

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

5 PIECE 90°ELBOW

AutoCAD SHX Text

4 PIECE 60°ELBOW

AutoCAD SHX Text

3 PIECE 45° ELBOW

AutoCAD SHX Text

2 PIECE 30° ELBOW

AutoCAD SHX Text 11.25%%D

AutoCAD SHX Text 22.5%%D

AutoCAD SHX Text 22.5%%D

AutoCAD SHX Text 22.5%%D

AutoCAD SHX Text 11.25%%D

AutoCAD SHX Text

RECTANGULAR DUCT

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text 45%%D

AutoCAD SHX Text

FLEX DUCT (MAXIMUM 5'-0" LENGTH)

AutoCAD SHX Text

VOLUME DAMPER

AutoCAD SHX Text M-501

AutoCAD SHX Text

AutoCAD SHX Text

HIGH EFFICIENCY TAKE-OFF DETAIL

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

RECTANGLE TO ROUND TRANSITION

AutoCAD SHX Text 1"

AutoCAD SHX Text

SEE PLAN FOR SIZE AND LOCATION

AutoCAD SHX Text

SECURE FLEX DUCT TO BOOT INLET COLLAR

AutoCAD SHX Text

CEILING

AutoCAD SHX Text

CEILING SUPPORT CHANNEL

AutoCAD SHX Text

SUPPLY DIFFUSER- SEE PLANS FOR SIZE AND LOCATION

AutoCAD SHX Text

DIFFUSER CONNECTION BOOT LINED WITH 1" ACOUSTICAL INSULATION

AutoCAD SHX Text

FOLDED SHEET METAL STRAP EACH SIDE OF BOX UP TO STRUCTURE

AutoCAD SHX Text M-501

AutoCAD SHX Text

AutoCAD SHX Text

SUPPLY DIFFUSER W/ FLEX DUCT DETAIL

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text M-501

AutoCAD SHX Text

SUPPORT FLEX DUCT AND DIFFUSER FROM STRUCTURE ABOVE

AutoCAD SHX Text M-501

AutoCAD SHX Text

AutoCAD SHX Text

DIFFUSER CONNECTION DETAIL

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

CEILING

AutoCAD SHX Text

NOTE: RETURN SIMILAR BUT WITHOUT DUCT

AutoCAD SHX Text

FLEX DUCT (MAXIMUM 5'-0" LENGTH) TO MIXING BOX - SEE PLAN FOR SIZE

AutoCAD SHX Text MAKE BEND RADIUS 1 1/2 x DUCT RADIUS

AutoCAD SHX Text

TIGHTENING BAND

AutoCAD SHX Text M-501

AutoCAD SHX Text

AutoCAD SHX Text

RECTANGULAR DUCT SUPPORT

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

DOUBLE FOLD STRAP AND SECURE TO TOP CHORD OF TRUSSES.

AutoCAD SHX Text

#10 SHEET METAL SCREW 6" ON CENTER, TYP.

AutoCAD SHX Text

NOTE: USE SPECIFIED SPACING AND NOT LESS THAN ONE SUPPORT PER BRANCH.

AutoCAD SHX Text

BEND TAB UNDER

AutoCAD SHX Text

DUCT

AutoCAD SHX Text 1 1/4" x 16 GAUGE SHEET METAL STRAP, TYPICAL

AutoCAD SHX Text M-501

AutoCAD SHX Text

AutoCAD SHX Text

ROUND DUCT SUPPORT DETAIL

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

NOTE: USE SPECIFIED SPACING AND NOT LESS THAN ONE SUPPORT PER BRANCH.

AutoCAD SHX Text

3/8" DIA. BOLT AND NUT

AutoCAD SHX Text

ROUND DUCT

AutoCAD SHX Text

DOUBLE FOLD STRAP AND SECURE TO TOP CHORD OF TRUSSES.

AutoCAD SHX Text

1-1/4" X 16 GA. SHEET METAL STRAP

AutoCAD SHX Text M-501

AutoCAD SHX Text

AutoCAD SHX Text

FIRE DAMPER & FIRE/SMOKE DAMPER DETAILS

AutoCAD SHX Text

NO SCALE

Mike Perez

C H

A N

I C

T

A I L

S

M-502

181 East 5600 South

Murray, Utah 84107

O: (801) 530-3148

F: (801) 530-3150 www.vbfa.com vbfa project #: 19540

C O

N T

R A

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L

A

L E

P

L O

T

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

C

E S

C

E N

M O

U N

T A

M

E

A

R

S

E

7654321

A N

S I

D

N

O V

E M

B E

R

T

E D

A

K

E

C

I T

Y

U

T

SHEET OF 31

F A

C

A

C H

A P

E L

K

I T

C H

N

O V

A T

I O

N

F

A C

I L I T

Y

M O

U N

T A

M

E

A

R

S

E

I D

A H

O

L

IC

EN

SE

D P

ROFESS I ONAL ENG

IN

E

ER

No. 354088

S TA T E O F U TAH

JAMES E.

NIGHTINGALE

Hilti Firestop Systems

Hilti Firestop Systems

System No. W-L-5028

SECTION A-A

W L

Page: 1 of 2

1. Wall Assembly — The 1 or 2 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features:

A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. OC.

B. Gypsum Board* — 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of opening is 7-1/2 in.

The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed.

2. Through Penetrants — One metallic pipe or tubing to be centered within the firestop system. Pipe or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes or tubing may be used:

A. Steel Pipe — Nom 4 in. diam (or smaller) Schedule 40 (or heavier) steel pipe.

B. Copper Tubing — Nom 2 in. diam (or smaller) Type L (or heavier) copper tubing.

C. Copper Pipe — Nom 2 in. diam (or smaller) Regular (or heavier) copper pipe.

A

Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.

February 08, 2006

F Ratings - 1 and 2 Hr (See Item 1) T Ratings - 3/4 Hr

L Rating at Ambient - Less Than 1 CFM/sq ft L Rating at 400 F - Less Than 1 CFM/sq ft

C US

CL

ASS IF IED

R

Page: 2 of 2

3. Tube Insulation — Plastics+ — Nom 3/4 in. thick acrylonitrile butadiene/polyvinyl chloride (AB/PVC) flexible foam furnished in the form of tubing. An annular space of min 0 in. (point contact) to max 1-1/2 in. is required within the firestop system.

See Plastics+ (QMFZ2) category in the Recognized Component Directory for names of manufacturers. Any Recognized Component tube insulation material meeting the above specifications and having a UL 94 Flammability Classification of 94-5VA may be used.

The hour T Rating of the firestop system is dependent on the hourly fire rating of the wall assembly in which it is installed, the size and type of through penetrant and the pipe covering thickness, as shown in the table below:

C US

CL

ASS IF IED

R

System No. W-L-5028

W L

F Ratings - 1 and 2 Hr (See Item 1) T Ratings - 3/4 Hr

L Rating at Ambient - Less Than 1 CFM/sq ft L Rating at 400 F - Less Than 1 CFM/sq ft

Wall Assembly Hr Rating Type + Through Penetrant Max Diam In.

1 A 4

1 A, B, or C 2

2 A 4

2 A, B, or C 2

+Indicates penetrant type as itemized in Item 2.

4. Fill, Void or Cavity Material* — Sealant — Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point contact location between pipe covering and gypsum wallboard, a min 1/2 in. diam bead of fill material shall be applied at the pipe covering/gypsum wallboard interface on both surfaces of wall.

HILTI CONSTRUCTION CHEMICALS, DIV OF

HILTI INC — FS-ONE Sealant

*Bearing the UL Classification Mark

A

1A

1B

Hilti Firestop Systems

System No. W-L-7040

SECTION A-A

W L

1. Wall Assembly — The fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory and shall include the following construction features:

A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. Additional framing members shall be used to completely frame around opening.

B. Gypsum Board* — Nom 5/8 in. thick with square or tapered edges. The gypsum wallboard type, number of layers and sheet orientation shall be as specified in the individual Wall and Partition Design Number. Max area of opening is 1300 in. with the dimension of 50 in. The hourly F rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed.

2. Steel Duct — Nom 24 in. by 48 in. (or smaller) No. 24 gauge (or heavier) galv steel duct to be installed within the firestop system. The annular space shall be min 0 (point contact) in. to a max 2 in. Duct to be rigidly supported on both sides of the wall assembly.

3. Firestop System — The firestop system shall consist of the following:

A. Fill, Void or Cavity Material*—Sealant — Min 5/8 in. thickness of fill material applied within annulus flush with both surfaces of wall. At point contact location, a min 1/2 in. diam bead of fill material shall be applied to the wall/duct interface on both surfaces of wall.

HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE Sealant, CP601S Elastomeric Firestop Sealant or CP606 Flexible

Sealant.

B. Steel Retaining Angle — No. 18 MSG (0.048 in.) galv steel angles cut to fit contour of duct with a 2 in. overlap on the duct and a min 1 in. overlap on the gypsum board assembly on both sufaces of wall. 2 in. leg of angle secured to duct with min No. 8 by 3/4 in. long sheet metal screws, spaced a max of 6 in. OC. When bead of fill material is used at joint contact locations, angles shall be installed prior to full material curing.

*Bearing the UL Classification Mark

Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.

November 13, 2001

F Ratings — 1 and 2 Hrs (See Items 1 and 3) T Rating — 0 Hr

C US

CL

ASS IF IED

R

1A

3B3A

1B

3B 3A

System No. C-AJ-7051

F Rating - 3 Hr

T Rating - 1 Hr

R

A

3B

3A

A

SECTION A-A

Page: 2 of 2

4. Pipe Covering — Min 1/2 in. (13 mm) to max 2 in. (51 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m3) glass fiber units jacketed on the outside with an all-service jacket. Longitudinal joints sealed with metal fasteners or factory-applied, self-sealing lap tape.

Transverse joints secured with metal fasteners or with butt tape supplied with the product. The annular space between the insulated pipe and the edge of the periphery of the opening shall be min 1/2 in. (13 mm) to a max 2-1/4 in. (57 mm). When thickness of pipe covering is less than 2 in. (51 mm), the T Rating for the firestop system is 0 hr.

See Pipe Equipment Covering — Materials — (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used.

4A. Pipe Covering — (Not Shown) — As an alternate to Item 4, max 2 in. (51 mm) thick cylindrical calcium silicate (min 14 pcf) units sized to the outside diam of the pipe or tube may be used. Pipe insulation secured with stainless steel bands or min 8 AWG stainless steel wire spaced max 12 in. (305 mm) OC. The annular space shall be min 1/2 in. (13 mm) to max 2-1/4 in. (57 mm).

5. Firestop System — The firestop system shall consist of the following:

A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material.

B. Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall.

HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant *Bearing the UL Classification Mark

C USR

CA

J 5

Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.

May 29, 2008Hilti Firestop Systems

System No. C-AJ-5091 F Rating — 2 Hr

T Ratings — 0 and 1 Hr (See Items 2 and 4) L Rating At Ambient — 4 CFM/Sq Ft

L Rating At 400 F — Less Than 1 CFM/Sq Ft

System No. C-AJ-1226

SECTION A-A

CA

J 1

A

Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.

June 27, 2007

F Rating — 3 Hr T Rating — 0 Hr

L Rating At Ambient — Less Than 1 CFM/Sq Ft L Rating At 400 F — 4 CFM/Sq Ft

C USRHilti Firestop Systems

1. Floor or Wall Assembly — Min 4-1/2 in. thick reinforced lightweight or normal weight (100-150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 32 in.

2. Metallic Sleeve — (Optional) Nom 32 in. diam (or smaller) Schedule 40 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces or extending a max of 3 in. above floor or beyond both surfaces of wall.

2A. Sheet Metal Sleeve — (Optional) Max 6 in. diam, min 26 ga galv steel provided with a 26 ga galv steel square flange spot welded to the sleeve at approx mid-height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. larger than the sleeve diam. The sleeve is to be cast in place and may extend a max of 4 in. below the bottom of the deck and a max of 1 in. above the top surface of the concrete floor.

2B. Sheet Metal Sleeve — (Optional) - Max 12 in. diam, min 24 ga galv steel provided with a 24 ga galv steel square flange spot welded to the sleeve at approx mid-height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. larger than the sleeve diam. The sleeve is to be cast in place and may extend a max of 4 in. below the bottom of the deck and a max of 1 in. above the top surface of the concrete floor.

3. Through-Penetrant — One metallic pipe, tube or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between penetrant and periphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. Penetrant may be installed with continuous point contact. Penetrant to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic penetrants may be used:

A. Steel Pipe — Nom 30 in. diam (or smaller) Schedule 10 (or heavier) steel pipe.

B. Iron Pipe — Nom 30 in. diam (or smaller) cast or ductile iron pipe.

C. Copper Pipe — Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe.

D. Copper Tubing — Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing.

E. Conduit — Nom 6 in. diam (or smaller) steel conduit.

F. Conduit — Nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT).

4. Firestop System — The firestop system shall consist of the following:

A. Packing Material — Min 4 in. thickness of min 4 pcf mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or sleeve or from both surfaces of wall or sleeve as required to accommodate the required thickness of fill material.

B. Fill, Void or Cavity Material* — Sealant — Min 1/4 in. thickness of fill material applied within the annulus, flush with top surface of floor or sleeve or with both surfaces of wall or sleeve. At the point or continuous contact locations between penetrant and concrete or sleeve, a min 1/4 in. diam bead of fill material shall be applied at the concrete or sleeve/ pipe penetrant interface on the top surface of floor and on both surfaces of wall.

HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant

*Bearing the UL Classification Mark

A

34B

14B

4A

System No. C-AJ-5090

SECTION A-A

CA

J 5

1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 8 in. (203 mm).

See Concrete Blocks (CAZT) Category in the Fire Resistance Directory for names of manufacturers.

2. Metallic Sleeve — (Optional) — Nom 8 in. (203 mm) diam (or smaller) Schedule 10 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces or extending a max of 3 in. (76 mm) above floor or beyond both surfaces of wall.

3. Through Penetrants — One metallic pipe or tubing to be centered within the firestop system. Pipe or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or tubing may be used:

A. Steel Pipe — Nom 4 in. (102 mm) diam (or smaller) Schedule 5 (or heavier) steel pipe.

B. Copper Pipe — Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper tubing.

C. Copper Tubing — Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing.

4. Tube Insulation — Plastics+ — Nom 3/4 in. (19 mm), thick acrylonitrile butadiene/polyvinyl chloride (AB/PVC) flexible foam furnished in the form of tubing. A annular space shall be min 1/2 in. (13 mm) to max of 1-1/2 in. (38 mm).

See Plastics+ (QMFZ2) Category in the Recognized Component Directory for names of manufacturers. Any Recognized Component tube insulation material meeting the above specifications and having a UL 94 Flammability Classification of 94-5VA may be used.

5. Firestop System — The firestop system shall consist of the following:

A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material.

B. Fill, Void or Cavity Material* — Sealant — Min 1/4 in. (6 mm) thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall.

HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant

*Bearing the UL Classification Mark

A

Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.

May 29, 2008

F Rating — 3 Hr T Rating — 0 Hr

L Rating At Ambient — 4 CFM/Sq Ft L Rating At 400 F — Less Than 1 CFM/Sq Ft

C USR

A

2 1 5B

5A

5B

Hilti Firestop Systems

System No. C-AJ-5091

SECTION A-A

CA

J 5

Page: 1 of 2

1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 19-1/2 in. (495 mm).

See Concrete Blocks (CAZT) category in the Fire Resistance directory for names of manufacturers.

2. Metallic Sleeve — (Optional) — Nom 20 in. (508 mm) diam (or smaller) Schedule 10 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces or extending a max of 3 in. (76 mm) above floor or beyond both surfaces of wall. If the steel sleeve extends beyond the top surface of the floor or both surfaces of the wall, the T Rating of the firestop system is 0 hr.

2A. Sheet Metal Sleeve — (Optional) - Max 6 in. (152 mm) diam, min 26 ga galv steel provided with a 26 ga galv steel square flange spot welded to the sleeve at approximately mid- height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve diam.

The sleeve is to be cast in place flush with bottom surface of floor and may extend a max of 1 in. (25 mm) above the top surface of the floor.

2B. Sheet Metal Sleeve — (Optional) - Max 12 in. (305 mm) diam, min 24 ga galv steel provided with a 24 ga galv steel square flange spot welded to the sleeve at approximately mid- height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve diam. The sleeve is to be cast in place flush with bottom surface of floor and may extend a max of 1 in. (25 mm) above the top surface of the floor.

3. Through Penetrants — One metallic pipe or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or tubing may be used:

A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.

B. Iron Pipe — Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe.

C. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe.

D. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing.

A

Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.

May 29, 2008

F Rating — 2 Hr T Ratings — 0 and 1 Hr (See Items 2 and 4)

L Rating At Ambient — 4 CFM/Sq Ft L Rating At 400 F — Less Than 1 CFM/Sq Ft

C USR

A

5B

5A

Hilti Firestop Systems

AutoCAD SHX Text 19540_M-501.dwg

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text

M. POND

AutoCAD SHX Text

J. NIGHTINGA

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text 03/12/2020

AutoCAD SHX Text

CAJ 7051

AutoCAD SHX Text

FIRESTOP SYSTEMS

AutoCAD SHX Text Reproduced by HILTI, Inc. Courtesy of

AutoCAD SHX Text Underwriters Laboratories, Inc.

AutoCAD SHX Text October 20, 2000

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text

US

AutoCAD SHX Text

1. Floor or Wall Assembly - Min 4-1/2 in. thick reinforced lightweight or Min 4-1/2 in. thick reinforced lightweight or normal weight (100-150 pcf) concrete. Wall may also be constructed of any Underwriters Laboratories Inc. Classified Concrete Blocks*. Max area of Concrete Blocks*. Max area of Max area of opening is 1024 in. sq. with a max dimension of 32 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory Concrete Blocks (CAZT) category in the Fire Resistance Directory (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Steel Duct - Nom 30 by 30 in. (or smaller) No. 24 gauge (or heavier) galv steel duct. Nom 30 by 30 in. (or smaller) No. 24 gauge (or heavier) galv steel duct. One steel duct to be positioned within the firestop system. The annular space shall be min 1/4 in. to a max 1-3/4 in. Duct to be rigidly supported on both sides of floor or wall assembly. 3. Firestop System - The firestop system shall consist of the following: The firestop system shall consist of the following: A. Packing Materials - Min 3-1/2 in. thickness of min 4 pcf mineral wool batt A. Packing Materials - Min 3-1/2 in. thickness of min 4 pcf mineral wool batt - Min 3-1/2 in. thickness of min 4 pcf mineral wool batt insulation firmly packed into opening as a permanent form between the bare steel duct and the periphery of the opening . Packing material to be recessed from top surface of floor or both surfaces of wall as required to accommodate the required thickness of fill material. B. Fill, Void or Cavity Material* - Sealant - Min 1 in. thickness of fill material B. Fill, Void or Cavity Material* - Sealant - Min 1 in. thickness of fill material - Min 1 in. thickness of fill material applied within annulus, flush with top surface of floor or both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI, INC. - CP606 Flexible Firestop Sealant or FS-ONE Sealant - CP606 Flexible Firestop Sealant or FS-ONE Sealant 4. Steel Retaining Angle - Nom 2 in. by 2 in. by No. 16 gauge (or heavier) steel Nom 2 in. by 2 in. by No. 16 gauge (or heavier) steel angles attached to all four sides of the steel duct on the top surface or both surfaces of the wall. The angles shall be attached with No. 8 (or larger) steel sheet metal screws spaced max of 1 in. from each end and a max of 3 in. OC. *Bearing the UL Classification Marking

Mike Perez

C H

A N

I C

H

E D

U L

E S

M-601

181 East 5600 South

Murray, Utah 84107

O: (801) 530-3148

F: (801) 530-3150 www.vbfa.com vbfa project #: 19540

C O

N T

R A

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L

A

L E

P

L O

T

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

C

E S

C

E N

M O

U N

T A

M

E

A

R

S

E

7654321

A N

S I

D

N

O V

E M

B E

R

T

E D

A

K

E

C

I T

Y

U

T

SHEET OF 31

F A

C

A

C H

A P

E L

K

I T

C H

N

O V

A T

I O

N

F

A C

I L I T

Y

M O

U N

T A

M

E

A

R

S

E

I D

A H

O

L

IC

EN

SE

D P

ROFESS I ONAL ENG

IN

E

ER

No. 354088

S TAT E O F U TAH

JAMES E.

NIGHTINGALE

GRILLES, REGISTERS AND DIFFUSERS

MAX

ID MANUFACTURER MODEL NC DESCRIPTION

D-1 METALAIRE 5700 20 24 X 24 MODULE WITH ROUND NECK

R-1 METALAIRE H4004 30 SIDEWALL EXHAUST 24 X 12 ZERO DEFLECTION

PROVIDE PLASTER FRAME FOR GYP WALL

G-1 METALAIRE CC5 10 22 X 22 CEILING GRILLE

EXHAUST FAN SCHEDULE

AIR FAN ELECTRICAL PHYSICAL

MAXIMUM FAN DIAMETER

MANUFACTURER AIRFLOW STATIC FAN WHEEL MOTOR MOTOR MOTOR HEIGHT

AND RATE PRESSURE SPEED DIAMETER SIZE BHP SPEED

ID MODEL NUMBER LOCATION TYPE

(CFM) (IN. WATER) (RPM) (IN) (HP) (HP) (RPM)

VOLT/PH/HZ

(IN)

NOTES

EF-1 PENN BARRY WFX18VGP WALL CENTIFUGAL 1000 0.25 493 18 1/8 0.074 493 120/1/60 39 / 33 1,2

1. FAN TO BE ENABLED TO RUN WHEN EXISTING PACKAGED UNIT FAN IS ON. FAN SHALL RUN AT 100% RPM WHEN BOTH RANGE HOODS ARE OFF. FAN SHALL RUN AT 75% RPM WHEN ONLY ONE RANGE HOOD IS ON. FAN SHALL RUN AT 50% WHEN BOTH RANGE HOODS ARE ON.

2. BASIS OF DESIGN MANUFACTURERS LISTED REFERENECE EQUAL MANUFACTURERS MEETING ALL SCHEDULED PERFORMANCE DATAT AND CRITERIA IN SPECIFICATIONS ARE ACCEPTABLE.

RANGE HOOD SCHEDULE

MANUFACTURER AIR PHYSICAL ELECTRICAL

AND MAXIMUM STATIC DRIVE MAX CONTROL

MODEL NUMBER AIRFLOW PRESSURE TYPE SONES TYPE

RATE

ID LOCATION TYPE

(CFM) (IN. WATER)

NOTES

RH-1 BROAN BCSEK130SS ABOVE RANGE DUCTED 250 0.1 DIRECT 1.5 MANUAL

120 VAC,60 HZ 1,2

1. INTEGRAL FAN AND LIGHT TO BE MANUALLY CONTROLLED BY UNIT MOUNTED SWITCHES

2. BASIS OF DESIGN MANUFACTURERS LISTED FOR REFERENCE EQUAL MANUFACTURERS MEETING ALL SCHEDULED PERFORMANCE DATA AND CRITERIA IN SPECIFICATIONS ARE ACCEPTABLE

AutoCAD SHX Text 19540_M-601.dwg

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text

M. POND

AutoCAD SHX Text

J. NIGHTINGA

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text 03/12/2020

Mike Perez

U M

B I N

G

S

Y M

B O

G

E

D

G

E N

E R

T

E S

P-000

VTR

LEGEND OF PLUMBING SYMBOLS AND ABBREVIATIONS

RPBP

GPM0.0

O F

S

T

A

S

PLUMBING PLUMBING CONT.

LINETYPES

SYMBOLS

181 East 5600 South

Murray, Utah 84107

O: (801) 530-3148

F: (801) 530-3150 www.vbfa.com vbfa project #: 19540

C O

N T

R A

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L

A

L E

P

L O

T

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

C

E S

C

E N

M O

U N

T A

M

E

A

R

S

E

7654321

A N

S I

D

N

O V

E M

B E

R

T

E D

A

K

E

C

I T

Y

U

T

SHEET OF 31

F A

C

A

C H

A P

E L

K

I T

C H

N

O V

A T

I O

N

F

A C

I L I T

Y

M O

U N

T A

M

E

A

R

S

E

I D

A H

O

L

IC

EN

SE

D P

ROFESS I ONAL ENG

IN

E

ER

No. 354088

S TAT E O F U TAH

JAMES E.

NIGHTINGALE

PLUMBING

GENERAL NOTES

PLUMBING CONT.

GENERAL NOTES

AutoCAD SHX Text 19540_P-000.dwg

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text

M. POND

AutoCAD SHX Text

J. NIGHTINGA

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text

PS

AutoCAD SHX Text

LB/HR.

AutoCAD SHX Text

GPM

AutoCAD SHX Text LATERAL STRAINER WITH BLOW-OFF VALVE, PROVIDE HOSE END WITH CAP WHERE DISCHARGE IS NOT PIPED TO DRAIN

AutoCAD SHX Text

(NAME)

AutoCAD SHX Text

FLANGE

AutoCAD SHX Text

PRESSURE GAUGE WITH PIGTAIL

AutoCAD SHX Text

PRESSURE GAUGE WITH SHUT-OFF COCK

AutoCAD SHX Text

DEMOLITION

AutoCAD SHX Text

FLEXIBLE EXPANSION JOINT

AutoCAD SHX Text

EXISTING PIPING TO BE REMOVED

AutoCAD SHX Text

EXISTING PIPING

AutoCAD SHX Text

NATURAL GAS

AutoCAD SHX Text

(NAME)

AutoCAD SHX Text

E(NAME)

AutoCAD SHX Text G

AutoCAD SHX Text

DN

AutoCAD SHX Text

UNION

AutoCAD SHX Text

FLOW METER ORIFICE

AutoCAD SHX Text

FLOW SWITCH

AutoCAD SHX Text

TEMPERATURE AND PRESSURE TEST PORT

AutoCAD SHX Text

PRESSURE SWITCH

AutoCAD SHX Text

CHECK VALVE

AutoCAD SHX Text

GAS COCK

AutoCAD SHX Text

RELIEF VALVE

AutoCAD SHX Text

GATE VALVE

AutoCAD SHX Text

GLOBE VALVE

AutoCAD SHX Text

CALIBRATED BALANCING VALVE WITH GPM INDICATED

AutoCAD SHX Text

SHUT-OFF COCK FOR USE WITH PRESSURE GAUGE

AutoCAD SHX Text

FLOW METER

AutoCAD SHX Text

90° ELBOW

AutoCAD SHX Text

45° ELBOW

AutoCAD SHX Text

THERMOMETER - TEMP RANGE AS INDICATED

AutoCAD SHX Text

ARROW INDICATES DIRECTION OF FLOW IN PIPE

AutoCAD SHX Text

LEADER INDICATES DOWNWARD SLOPE

AutoCAD SHX Text

RISER - DOWN (ELBOW)

AutoCAD SHX Text

RISER - UP (ELBOW)

AutoCAD SHX Text

BRANCH - SIDE CONNECTION

AutoCAD SHX Text

CLEAN-OUT

AutoCAD SHX Text

FLOOR CLEAN-OUT OR CLEAN-OUT TO GRADE

AutoCAD SHX Text

VENT THRU ROOF

AutoCAD SHX Text

DOMESTIC COLD WATER (DCW)

AutoCAD SHX Text

DOMESTIC HOT WATER (DHW)

AutoCAD SHX Text

DOMESTIC HOT WATER RETURN (DHWR)

AutoCAD SHX Text

PLUMBING FIXTURES

AutoCAD SHX Text

POINT OF CONNECTION

AutoCAD SHX Text

SECTION TAG - TOP FIGURE IS SECTION NO. BOTTOM FIGURE IS SHEET NO.

AutoCAD SHX Text

DETAIL TAG - TOP FIGURE IS DETAIL NO. BOTTOM FIGURE IS SHEET NO.

AutoCAD SHX Text

EQUIPMENT IDENTIFICATION

AutoCAD SHX Text

KEYED NOTE IDENTIFICATION

AutoCAD SHX Text

FIXTURE FROM LEVEL ABOVE

AutoCAD SHX Text P-1

AutoCAD SHX Text

EF

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text M-101

AutoCAD SHX Text A

AutoCAD SHX Text M101

AutoCAD SHX Text

BRANCH - BOTTOM CONNECTION

AutoCAD SHX Text

BRANCH - TOP CONNECTION

AutoCAD SHX Text

FLOOR SINK

AutoCAD SHX Text

FLOOR DRAIN

AutoCAD SHX Text

AIR VENT-MANUAL

AutoCAD SHX Text

AIR VENT-AUTO

AutoCAD SHX Text

REDUCER

AutoCAD SHX Text

HOSE BIBB

AutoCAD SHX Text

PIPE CAP

AutoCAD SHX Text

SWITCH

AutoCAD SHX Text

THERMOSTAT

AutoCAD SHX Text

SENSOR

AutoCAD SHX Text

INLINE PUMP

AutoCAD SHX Text

INLINE PUMP

AutoCAD SHX Text

AutoCAD SHX Text

WATER HAMMER ARRESTOR

AutoCAD SHX Text

CONCENTRIC REDUCER

AutoCAD SHX Text

ECCENTRIC REDUCER

AutoCAD SHX Text

SEWER (BELOW GRADE)

AutoCAD SHX Text

SEWER (ABOVE GRADE)

AutoCAD SHX Text

VENT (SEWER)

AutoCAD SHX Text

FCO

AutoCAD SHX Text

COTG

AutoCAD SHX Text

GATE VALVE - NON RISING STEM

AutoCAD SHX Text

ANGLE VALVE

AutoCAD SHX Text

BALANCING COCK

AutoCAD SHX Text

VALVE IN RISE

AutoCAD SHX Text

FILL PORT

AutoCAD SHX Text

DRAIN PAN AND P-TRAP

AutoCAD SHX Text

RISE OR DROP

AutoCAD SHX Text

REDUCED PRESSURE BACKFLOW PREVENTOR W/ DRAIN PAN

AutoCAD SHX Text

THERMOSTATIC MIXING VALVE

AutoCAD SHX Text 03/12/2020

AutoCAD SHX Text

1. UNLESS OTHERWISE NOTED, SLOPE PIPE AS FOLLOWS: UNLESS OTHERWISE NOTED, SLOPE PIPE AS FOLLOWS: WASTE BRANCHES: 1/4" PER FOOT; WASTE MAINS: 1/4" PER FOOT. 2. ALL WORK DONE SHALL BE PERFORMED WITH WATER ALL WORK DONE SHALL BE PERFORMED WITH WATER CONTROL IN MIND. CONTAINMENT OF WATER IS NECESSARY TO PREVENT WATER FROM DAMAGING AREAS BELOW. 3. PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE. PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE. FIELD VERIFY EXACT PIPE ROUTING AND COORDINATE WITH ALL OTHER TRADES. 4. NO PIPING TO RUN OVER ELECTRICAL PANELS, VFD'S NO PIPING TO RUN OVER ELECTRICAL PANELS, VFD'S OR MCC'S. PROTECT EQUIPMENT WITH A 42" DEEP ZONE IN FRONT OF PANELS, VFD'S, AND MCC'S. 5. CONTRACTOR TO PROVIDE VALVE IDENTIFICATION AND CONTRACTOR TO PROVIDE VALVE IDENTIFICATION AND LOCATION ON ALL CEILING TILES WHERE VALVES ARE LOCATED. 6. PIPING AND ROUTING SHOWN, INCLUDING ALL BELOW PIPING AND ROUTING SHOWN, INCLUDING ALL BELOW FLOOR DECK PIPING, IS APPROXIMATE. IT IS UP TO THE CONTRACTOR TO FIELD VERIFY THE EXACT LOCATION AND SIZE OF ALL PIPING. 7. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE MOUNTING HEIGHTS, DIMENSIONS, AND OTHER REQUIREMENTS. 8. CONTRACTOR TO VERIFY CONNECTION SIDE OF CONTRACTOR TO VERIFY CONNECTION SIDE OF ACCESSIBILITY COMPLIANT FIXTURES AND ADJUST ACCORDINGLY. INSTALL FLUSH VALVES HANDLES ON WIDE SIDE OF ALL FIXTURES. 9. INSTALL ALL DOMESTIC WATER LINES BELOW INSTALL ALL DOMESTIC WATER LINES BELOW DUCTWORK. 10. INSTALL A 24" X 24" ACCESS DOOR BELOW ALL INSTALL A 24" X 24" ACCESS DOOR BELOW ALL ISOLATION VALVES, BALANCING VALVES AND WATER HAMMER ARRESTORS WHERE MOUNTED ABOVE HARD CEILINGS. 11. MOUNT ALL ISOLATION VALVES, CONTROL VALVES, MOUNT ALL ISOLATION VALVES, CONTROL VALVES, BALANCING VALVES, ETC. NEAR CEILING HEIGHT FOR ACCESSIBILITY. 12. INSTALL ALL EQUIPMENT WITH SUFFICIENT CLEARANCE INSTALL ALL EQUIPMENT WITH SUFFICIENT CLEARANCE FOR MAINTENANCE PER MANUFACTURERS RECOMMENDATION. 13. COORDINATE ALL FLOOR PENETRATIONS WITH COORDINATE ALL FLOOR PENETRATIONS WITH STRUCTURAL AND PROVIDE SLEEVES AS NECESSARY. 14. COORDINATE EXACT LOCATION OF PLUMBING WITH COORDINATE EXACT LOCATION OF PLUMBING WITH STRUCTURAL MEMBERS, LIGHTS, REFLECTED CEILING, DUCTWORK, MECHANICAL PIPING, FIRE PROTECTION, AND OTHER TRADES, TYPICAL. 15. COORDINATE THE LOCATION OF THE FLOOR DRAIN, COORDINATE THE LOCATION OF THE FLOOR DRAIN, SHOWER DRAIN, OR FLOOR SINK WITH ARCHITECTURAL AND STRUCTURAL, TYPICAL. 16. SEE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES SEE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES OF WASTE, VENT AND DOMESTIC WATER TO/FROM SINGLE FIXTURE. 17. COORDINATE EXACT LOCATION OF PLUMBING PIPING COORDINATE EXACT LOCATION OF PLUMBING PIPING WITH STRUCTURAL MEMBERS, LIGHTS, REFLECTED CEILING PLANS, ELECTRICAL CONDUITS, DUCTWORK, MECHANICAL AND FIRE PROTECTION PIPING, AND ALL OTHER TRADES AND ALL EXISTING CONDITIONS. 18. LOCATE CIRCUIT SETTERS, VALVES, WATER HAMMER LOCATE CIRCUIT SETTERS, VALVES, WATER HAMMER ARRESTORS, ETC. IN ACCESSIBLE LOCATIONS. PROVIDE 24"X24" ACCESS PANEL WHERE ITEM IS LOCATED ABOVE A HARD CEILING. 19. ALL PIPE AND DUCT SIZES SHALL REMAIN THE SAME ALL PIPE AND DUCT SIZES SHALL REMAIN THE SAME SIZE SHOWN, IN THE DIRECTION OF FLOW, UNTIL SHOWN OTHERWISE.

AutoCAD SHX Text INSTALL CLEANOUTS IN DRAIN PIPING AS INDICATED, AND WHERE NOT INDICATED, ACCORDING TO THE FOLLOWING. SIZE SAME AS DRAINAGE PIPING UP TO 4" NPS. USE 4" NPS FOR LARGER. DRAINAGE PIPING UNLESS LARGER CLEANOUT IS INDICATED. LOCATE AT MINIMUM INTERVALS OF 50 FT FOR PIPING 4" NPS AND SMALLER AND 100 FT FOR LARGER PIPING. LOCATE AT THE BASE OF EACH VERTICAL STACK.

AutoCAD SHX Text 20.

AutoCAD SHX Text a)

AutoCAD SHX Text b)

AutoCAD SHX Text c)

AutoCAD SHX Text CONTRACTOR TO PROVIDE VALVE IDENTIFICATION AND LOCATION ON ALL CEILING TILES WHERE VALVES ARE LOCATED. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PERTAINING TO THE PLUMBING SYSTEMS AND COORDINATE ALL DEMOLITION WORK WITH THE OWNER PRIOR TO ANY SYSTEM SHUT-DOWN. EXISTING SYSTEMS SHOWN LIGHT. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY DEMOLITION TO MATCH EXISTING.

AutoCAD SHX Text 21.

AutoCAD SHX Text 22.

AutoCAD SHX Text 23.

AutoCAD SHX Text 24.

Mike Perez

RPBP

EXISTING RPBP

(E)NFH

EXISTING ICE MACHINE

EXISTING

PACKAGED

UNIT

P L

U M

B I N

G

D

E M

O L

I T

I O

N

F

L O

A

N

PD-101

8'0 4' 16'

KEY NOTES

EXTEND NEW 4" SANITARY AND CONNECT TO

EXISTING APPROXIMATELY AS SHOWN. VERIFY

EXISTING INVERT AND CONTACT COR IF DEPTH IS NOT

SUFFICIENT FOR NEW WORK.

DRAIN FOR EXISTING ICE MACHINE IS CONNECTED TO

A CONDENSATE PUMP AND PUMPED TO CLOSEST

DRAIN. DEMOLISH DRAIN SYSTEM.

REMOVE EXISTING RPBP AND PIPING THAT SERVES

ICE MACHINE. INSTALL IN NEW LOCATION UNDER NEW

CONSTRUCTION PHASE.

EXISTING NON-FREEZE WALL HYDRANT TO REMAIN.

PLUMBING DEMOLITION FLOOR PLAN

181 East 5600 South

Murray, Utah 84107

O: (801) 530-3148

F: (801) 530-3150 www.vbfa.com vbfa project #: 19540

C O

N T

R A

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L

A

L E

P

L O

T

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

C

E S

C

E N

M O

U N

T A

M

E

A

R

S

E

7654321

A N

S I

D

N

O V

E M

B E

R

T

E D

A

K

E

C

I T

Y

U

T

SHEET OF 31

F A

C

A

C H

A P

E L

K

I T

C H

N

O V

A T

I O

N

F

A C

I L I T

Y

M O

U N

T A

M

E

A

R

S

E

I D

A H

O

L

IC

EN

SE

D P

ROFESS I ONAL ENG

IN

E

ER

No. 354088

S TA T E O F U TAH

JAMES E.

NIGHTINGALE

AutoCAD SHX Text 19540_PD-101.dwg

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text

M. POND

AutoCAD SHX Text

J. NIGHTINGA

AutoCAD SHX Text

J. NIGHTINGALE

AutoCAD SHX Text N

AutoCAD SHX Text

SCALE: 3/8"=1'-0"

AutoCAD SHX Text 03/12/2020

Mike Perez

(E)NFH

S-1

S-3

S-2

FS-1

OB-1

GI-1

S

EXISTING

PACKAGED

UNIT

RCP

WH

4"

3"

1 1/4"

1"

G

G

3"

2"

G

1 1/4"

FS-1

1/2"

3/4"

OB-1

1/2"

3/4"

3/4"

1/2"

2"

1 1/2" V

3" VTR

G

BELOW FLOOR

1/2"

EXPANSION

TANK

1 1/4"

1 1/4"

P L

U M

B I N

G

F

L O

A

N

P-101

8'0 4' 16'

KEY NOTES

EXTEND NEW 4" SANITARY AND CONNECT TO

EXISTING APPROXIMATELY AS SHOWN. VERIFY

EXISTING INVERT AND CONTACT COR IF DEPTH IS NOT

SUFFICIENT FOR NEW WORK.

CONNECT NEW NATURAL GAS LINE TO EXISTING,

EXTEND INTO BUILDING AND CONNECT TO NEW GAS

APPLIANCES. CONTRACTOR TO VERIFY EXISTING GAS

PRESSURE REGULATOR CAN HANDLE INCREASED

LOAD AND REPLACE IF NECESSARY. SEE SCHEMATIC

FOR PIPE SIZES.

SOLENOID VALVE IN NATURAL GAS SERVICE TO

KITCHEN. VALVE SHALL CLOSE ON ACTIVATION OF

THE BUILDING FIRE ALARM OR MANUAL SWITCH.

CONNECT NEW 1-1/4" DCW INTO EXISTING MAIN

LOCATED WITHIN THE CRAWL SPACE AND EXTEND UP

INTO STORAGE ROOM AND ROUTE TO NEW WATER

HEATER AND FIXTURES AS SHOWN.

EXTEND 3/4" DCW, 3/4" DHW AND 1/2" DHWR THRU

BACK OF CABINETRY, IN CONDITIONED SPACE, TO

3-COMPARTMENT SINK. INSULATE ALL PIPING WITH

PVC JACKETED INSULATION.

SAW CUT / PATCH FLOOR AND INSTALL 2" SAN WITHIN

THE CRAWL SPACE TO SINK S-1 & S-3. INSTALL 3" PVC

PIPE WITH LONG SWEEP ELBOW WITHIN CRAWL

SPACE FROM MECH ROOM TO 6" ABOVE FLOOR

UNDER SINK CABINETRY. ROUTE 1/2" TYPE 'L' SOFT

COPPER DCW, DHW, & DHWR LINES WITHIN 3" PVC

PIPE TO SINKS.

GREASE INTERCEPTOR UNDER 3 COMPARTMENT SINK,

DISCHARGE TO FLOOR SINK. SEMI-RECESSED INSTALL

REQUIRED FOR VERTICAL CLEANING REQUIREMENT.

MANUAL SWITCH TO CLOSE NATURAL GAS SOLENOID

SHUT OFF VALVE SERVING KITCHEN GAS APPLIANCES.

OUTLET BOX (OB-1) FOR WATER CONNECTION TO ICE

MAKER IN REFRIGERATOR. ROUTE 1/2" DCW FROM

MAIN TO OB-1 AS SHOWN.

THIS AREA RESERVED FOR FIRE PROTECTION

STANDPIPE AND CONTROLS. SEE FIRE PROTECTION

DRAWINGS. DOMESTIC COLD WATER SOURCE FROM

FIRE PROTECTION STANDPIPE.

PROVIDE TWO DOMESTIC WATER BALANCE VALVES.

ONE FOR EACH BRANCH TO ENSURE FLOW IN BOTH.

SEE ISLAND VENT DETAIL.

INSTALL RELOCATED RPBP FOR ICE MACHINE WATER

SUPPLY.

OUTLET BOX (OB-1) FOR RELOCATED ICE MAKER

ROUTE 1/2" DCW TO BOX.

PROVIDE 1/2" DHW TO UNDER COUNTER DISHWASHER

AT ISLAND. EXTEND WASTE & VENT TO ISLAND

SOURCE.

2-HORSEPOWER FOOD DISPOSAL INSTALLED AT LEFT

FACING SINK COMPARTMENT AND DIRECT

CONNECTED TO WASTE LINE BELOW.

ROUTE VENT PIPING FROM DISPOSAL WASTE PIPE

AROUND WINDOW FRAME TO CEILING CAVITY THEN

ONTO VENT PIPING CONNECTED TO VENT PIPING

CONNECTED TO VENT THRU ROOF.

PLUMBING FLOOR…