3836 - HDR Engineering - Final Report - MHAFB Bld 2610.pdf
PDF 1 MB Posted
- Attached to
- Repair Facility 2610 Federal contract opportunity
- Solicitation number
- FA4897-09-R-0015_
About this file
Asbestos Containing Material Lead Based Paint Surveys and Reports
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 2610A-Amendment 0006 Drawing.pdf | ||
| Amendment 0006.doc | DOC document | |
| Amendment 0005.doc | DOC document | |
| Amendment 0004.doc | DOC document | |
| AMENDMENT 0003.doc | DOC document | |
| FAC 2610 - Furnishings List.docx | DOCX document | |
| Emergency Roof Shoring B2610 - Final Report | — | |
| DIGITALSENDER_20090729_084248_0150.pdf | ||
| SITE VISIT ANNOUCEMENT.docx | DOCX document | |
| Drawings Repair 2610.pdf | ||
| Amendment 0002.doc | DOC document | |
| Solicitation 15 Jul 09 Amendment .doc | DOC document | |
| Repair Fac 2610 - Addendum 1.doc | DOC document | |
| Notification of Complaince with Insurance.doc | DOC document | |
| DETERMINATION OF RESPONSIBILITY RFP.doc | DOC document | |
| 2610 MHAFB 100 Resubmittal PDF SET.pdf | ||
| B2610 - ACM-LBP Technical Specs(Use).doc | DOC document | |
| Approved PPT Questionnaire.doc | DOC document | |
| Solicitation 15 Jul 09 .doc | DOC document | |
| Information to Offerors.doc | DOC document | |
| ID10_dvb_July 3.mht | MHT file |
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
14 Mar 08
Mountain Home AFB
Repair Facility 2610
Asbestos Containing Material
Lead Based Paint Surveys and Reports
February, 2008
ASBESTOS AND LEAD SURVEY
AND REPORT
REPAIR FACILITY 2610
480 5TH Street
MOUNTAIN HOME AFB, IDAHO
Presented By:
Industrial Hygiene Resources 206 Murray Street Boise, ID 83714 (208) 323-8287
Harry Beaulieu, PhD, CIH, CSP
INTRODUCTION
On February 5th and 6th, 2008, Industrial Hygiene Resources (IHR) performed an asbestos and lead (Pb) paint survey on the Consolidated Service Center Facility, Building 2610 for HDR Engineering, Inc., of Boise, Idaho. Building 2610 is located at 480 E-Street on the Mountain Home Air Force Base (MHAFB) near Mountain Home, Idaho. Mr. Zach Hall, PE, PMP of HDR Engineering, Project Manager, authorized the survey. The survey was conducted to identify asbestos containing building materials (ACBM) and lead (Pb) based paints, prior to disturbance for remodeling or demolition purposes. This asbestos and lead survey meets EPA, DEQ and OSHA regulatory requirements. Mr. Hall provided IHR with a copy of the floor plan of the building. Mr. Ed O’Reilly, represented MHAFB and Mr. Larry Rodgers, CES/CEOHV provided IHR with access to the building and previous sampling data.
BACKGROUND
The structure is primarily one-story with approximately 49,000 square feet of building space with various elevated storage and mezzanines. The original portion of the building was built in the 1970’s, with additions to the east and west ends of the original building in the 1980’s. The building exterior is a concrete “Tip up” construction design with an exposed aggregate architectural finish. The interior walls are wood and metal framed covered with drywall, and the floors are concrete on the ground floor and wood on the mezzanine.
The roof is relatively flat and has approximately 1” of gravel ballast which was recently replaced. The roof is a “Malarkey” built-up roof system, consisting of gravel ballast over 4-ply, hot mopped membranes, over 4” rigid insulation, over ¾” perlite. All areas of the building were inspected except the Post Office where because of security access was denied (see figure 1).
ASBESTOS SAMPLING
AHERA Building Inspectors, Jeff Brown, and Steve Mabe, met with Mr. Larry Rodgers (MHAFB Environmental Operations) to review existing asbestos sampling data for building 2610. After reviewing the existing data, 42 additional bulk samples of suspect asbestos containing building material (ACBM) were collected. See the attached figures for floor plans, sampling locations and material locations.
ACM, under current regulation is defined as material with an asbestos content greater than 1% by volume. Any sample analyzed by “polarized light microscopy” (PLM) method as containing a trace to less than 10% asbestos must be reanalyzed by “point count method” or may be assumed to be ACM. All samples were analyzed by International Asbestos Testing Laboratories (IATL), of Mount Laurel, New Jersey. IATL is an AIHA accredited laboratory and participant in the NVLAP/NIST program.
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc 1
POINT COUNTING OF COMPOSITE ANALYSIS (ASBESTOS)
One roof flashing bulk sample was analyzed by PLM as containing greater than 1% asbestos. IHR recommended that sample FL-01-B be analyzed by “Point Counting Analysis” to meet EPA and OSHA requirements. For laboratory results of the sampled materials see Table I of this report. The result of the point counting was:
Sample ID Layer/Description Point Counting Results
FL-01-B Flashing around roof penetrations PC-3.1%, Chrysotile
The flashing material around the roof penetrations will need to be removed prior to and if disturbed during renovation or demolition. The point counting of analysis of greater than (>) 1.00% is the EPA and OSHA threshold of a regulated amount. Point counting of analysis for materials less than (<) 1% is not a regulated asbestos containing material.
The materials <1% may remain in the structure during demolition and may be disposed of as construction debris. IHR recommends that the materials >1% be removed from the structure prior to demolition.
ASBESTOS CONTAINING MATERIALS
CONCLUSION/RECOMMENDATIONS (ACM)
The following identifies the material, location, quantity and condition of all materials identified as containing asbestos and remaining in the structure.
Samples FL-01-A, B & C consists of approximately 100 L.F., of roof flashing that is located around each roof penetration on all three roofs. One of the samples contained greater than 3.0% Chrysotile in the flashing. The material was rated as being in good condition with no visual damage. IHR recommends the material be removed by qualified personnel and disposed of as asbestos containing waste material prior to demolition of the structure.
Certified and trained professional should remove the asbestos containing materials and properly dispose of them in a landfill that accepts such materials. Prior to any removal and/or demolition activities a notification form must be completed and mailed or hand delivered to the local DEQ office in Boise. Asbestos abatement companies are accustom to these forms and can help complete and understand the requirements.
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc 2
TABLE I
ASBESTOS SAMPLE RESULTS
Sample Number Description Percent/Asbestos
VFT-01-A 12” Vinyl Floor Tile & Mastic in Hallways and offices.
a. tan floor tile ND
b. tan mastic ND
VFT-01-B 12” Vinyl Floor Tile & Mastic in Hallways and offices.
a. tan floor tile ND
b. tan mastic ND VFT-01-C 12” Vinyl Floor Tile & Mastic in Hallways and offices.
a. tan floor tile ND
b. tan mastic ND
VFT-02-A 12” Vinyl Floor Tile & Mastic in Hallways and offices.
a. tan floor tile ND
b. yellow mastic ND VFT-02-B 12” Vinyl Floor Tile & Mastic First Floor
a. tan floor tile ND
b. yellow mastic ND VFT-02-C 12” Vinyl Floor Tile & Mastic First Floor
a. tan floor tile ND
b. yellow mastic ND
CT-01-A 2x4 Suspended Ceiling Tile with holes-First Floor
a. tan ceiling tile ND CT-01-B 2x4 Suspended Ceiling Tile with holes-First Floor
a. tan ceiling tile ND CT-01-C 2x4 Suspended Ceiling Tile with holes -First Floor
a. tan ceiling tile ND
CT-02-A 2x4 Suspended Ceiling Tile with fissures -First Floor
CT-02-B 2x4 Suspended Ceiling Tile with fissures -First Floor
a. tan ceiling tile ND CT-02-C 2x4 Suspended Ceiling Tile with fissures -First Floor
TABLE I (cont.)
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc 3
CT-03-A 2x4 Suspended Ceiling Tile First Floor
a. tan ceiling tile ND CT-03-B 2x4 Suspended Ceiling Tile First Floor
a. tan ceiling tile ND CT-03-C 2x4 Suspended Ceiling Tile First Floor
a. tan ceiling tile ND
SV-01-A Blue Linoleum & Mastic – east entrance
a. blue vinyl sheet flooring ND
b. tan mastic ND SV-01-B Blue Linoleum & Mastic – east entrance
a. blue vinyl sheet flooring ND
b. tan mastic ND SV-01-C Blue Linoleum & Mastic – east entrance
a. blue vinyl sheet flooring ND
b. tan mastic ND
SV-02-A Grey Linoleum & Mastic – Old meat area
a. grey vinyl sheet flooring ND
b. off-white mastic ND SV-02-B Grey Linoleum & Mastic – Old meat area
a. grey vinyl sheet flooring ND
b. off-white mastic ND SV-02-C Grey Linoleum & Mastic – Old meat area
a. grey vinyl sheet flooring ND
b. off-white mastic ND
JF-01-A Exterior Wall Joint Filler-New East Addition
a. white cementitious ND
b. tan foam ND JF-01-B Exterior Wall Joint Filler-New East Addition
a. white cementitious ND
b. tan foam ND JF-01-C Exterior Wall Joint Filler-New East Addition
a. white cementitious ND
b. tan foam ND
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc 4
JF-02-A Exterior Wall Joint Filler – Original Bld.
a. off-white, non-fibrous ND JF-02-B Exterior Wall Joint Filler – Original Bld.
a. off-white, non-fibrous ND JF-02-C Exterior Wall Joint Filler – Original Bld.
a. off-white, non-fibrous ND
DW-01-A Textured Drywall & Mud Through Out Bldg.- New Additions
a. off-white sheetrock ND DW-01-B Textured Drywall & Mud Through Out Bldg.- New Additions
a. off-white sheetrock ND DW-01-C Textured Drywall & Mud Through Out Bldg.- New Additions
a. off-white sheetrock ND
b. white joint compound ND
I-01-A Black Insulation Covering HVAC Lines in Mech. Rm.
a. black tar ND I-01-B Black Insulation Covering HVAC Lines in Mech. Rm.
a. black tar ND I-01-C Black Insulation Covering HVAC Lines in Mech. Rm.
a. black tar ND
EB-01-A Hard Fitting/elbow in old grocery area
a. tan insulation ND EB-01-B Hard Fitting/elbow in old grocery area
a. tan insulation ND EB-01-C Hard Fitting/elbow in old grocery area
a. tan insulation ND
FL-01-A Roof Flashing
a. black roof material ND FL-01-B Roof Flashing
a. black roof material 3.1 (PC) FL-01-C Roof Flashing
a. black roof material ND
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc 5
RF-01-A Roofing
a. black/tan roof material ND RF-01-B Roofing
a. black/tan roof material ND RF-01-C Roofing
a. black/tan roof material ND
(Bold) indicates regulated (>1%) asbestos containing materials ND = None Detected PC = Indicates stratified point count method performed
PREVIOUS ASBESTOS SAMPLING REPORT
IHR relied on previous asbestos building inspections and removal documentation that was provided by MHAFB. Two asbestos inspections were completed on building 2610 that were focused on remodeling inside the building. Northern Industrial Hygiene, Inc. of Burien, WA completed an asbestos survey that only included sampling for the remodeling of the 366th SVS/CPU room which is located to the east of the current post office location (see figure & appendix). No asbestos was identified in the wallboard (sheetrock), tan pebbled vinyl, carpet mastics, ceramic tile mastics, or drop-in ceiling panels.
In 1991, HAZTOX of Meridian, Idaho collected bulk samples of green floor tile for the new bakery area project. The green tile was 3-5% Chrysotile, while the mastic was 5-10% Chrysotile. IHR investigated the purported area of the new bakery area and was unable to locate either the green tile or black mastic. This area may have been abated at some time in the past, however, no documents were provided to IHR to substantiate this.
MHAFB also provided an EPA notification of demolition and renovation for the boiler rooms of building 2610. According to the notification, Associated Insulation, Inc. of Sunset, Utah removed 42 linear feet of asbestos piping from the boiler room in July of 2001. All piping in the boiler rooms were fiberglass.
LEAD BASE PAINT SAMPLING
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc 6
Mr. Brown and Mr. Mabe, collected six (6) paint chip samples that were analyzed for lead (Pb) content. Sample locations, material descriptions and quantities are documented in the attached tables and figures.
The Housing and Urban Development (HUD) and Bureau of Indian Affairs (BIA) have established regulations for lead based paint (LBP). The disturbance of lead (Pb) containing paint is governed by the Occupational Safety and Health Association (OSHA).
Regulated lead (Pb) paint is defined as paint containing > 5,000 parts per million (ppm) or 0.5% lead.
All lead (Pb) containing waste or structural building members to be disposed of must be submitted for Toxic Characterization Leachate Procedure (TCLP) analysis prior to disposal. Any material analyzed as containing > 5 milligrams per liter of leachate must be disposed of as hazardous waste at a proper landfill. All bulk paint chip samples were analyzed by analyzed by IATL of Mt. Laurel, New Jersey and this lab is accredited for this procedure. See the attached figures for general arrangement of the building and sample locations.
LEAD BASE PAINT (LBP)
CONCLUSION/RECOMMENDATIONS (LBP PAINT CHIP)
Two of the six paint chips were analyzed as containing greater than 0.5% lead. The two positive paint chip samples were collected in the Mobility Command Area located on the west end of the building. Pb-04 was collected from the yellow paint on the floor of the mobility area. IHR also noticed that this same yellow paint was located on “push carts” that were inside the mobility area.
Pb-05 was collected from the white paint and red primer on the interior wide-flange steel, vertical beams inside the mobility area. The exterior coating is white and has a red primer as a base. If MHAFB elects to remove the vertical support columns in the mobility area, they can unbolt the columns from the floor and ceiling, and save or store the columns without having to abate them. However, if welding, sanding, or grinding will be involved during the demolition or renovation, then lead abatement would be necessary.
TABLE II
LEAD PAINT CHIP SAMPLE RESULTS
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc 7
Sample Number Description Percent/Lead Paint
Pb-01 Interior Hand Rail – Dark Brown 0.0097
Pb-02 Door Frame – Light Brown 0.018
Pb-03 Mobility Roof Ladder – Black 0.015
Pb-04 Yellow Floor Paint 0.79***
Pb-05 Support Columns - White 8.0
Pb-06 Mechanical Room Interior Wall - White 0.012
*** Matrix/substrate interference possible.
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc 8
DRAWINGS
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc 9
N
I nd ust ria l H yg ien e R eso ur ces F\
IH
R
\3
Fi gu re
Fi gu re
A sb es to s & L ea d
(P b)
P ai nt C hi p
Sa m pl e
L oc at io ns B ui ld in g
M ou nt ai n
H om e A ir
F or ce b as e
M ou nt ai n H om e, I da ho
M ai n En try
Pb -0
H an dr ai l
-0
V
FT
-0 1A
, B
C
Fl oo r T ile
SV
-0
1A , B
C
S he et V in yl
SV
-0
2A , B
C
Sh ee t V in yl
C
T-
A , B
C
C ei lin g
Ti le
C
T-
A , B
C
C ei lin g
Ti le
C T-
A
, B
C C ei lin g Ti le
JF
-0
1A , B
C
Jo in t F ill er
V
FT
-0 2A
, B
C
Fl oo r T ile
JF
-0
2A , B
C
Jo in t F ill er
D W
-0 1A
C om po si te D ry w al l
Pb -0
D oo r J am b
Pb -0
Fi xe d
La dd er
Pb -0
In t.
W al l
Pb -0
Fl oo r P ai nt
Pb -0
Su pp or t C ol um n
Se co nd F lo or
EB
-0
1A , B
C
TS
I F itt in gs I-
A
, B
C A
C li ne In su la tio n
D W
-0 1B
C om po si te D ry w al l
D W
-0 1C
C om po si te D ry w al l
FL
-0
1A , B
C
R oo f F la sh in g
FL
-0
1A , B
C
R oo fin g
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc 10
Appendicies
Laboratory
Reports
| Cover |
| Asbestos and Lead Survey |
| POINT COUNTING OF COMPOSITE ANALYSIS (ASBESTOS) |
| Sample ID Layer/Description Point Counting Results |
Certified and trained professional should remove the asbestos containing materials and properly dispose of them in a landfill that accepts such materials. Prior to any removal and/or demolition activities a notification form must be completed and mailed or hand delivered to the local DEQ office in Boise. Asbestos abatement companies are accustom to these forms and can help complete and understand the requirements.
| Appendicies |
| Appendicies |
| Laboratory Reports |
| Laboratory Reports |
| IATL Asbestos Results |
| MHAFB - Historical Reports |
| IATL Lead Results |
Appendicies
INTRODUCTION
On February 5th and 6th, 2008, Industrial Hygiene Resources (IHR) performed an asbestos and lead (Pb) paint survey on the Consolidated Service Center Facility, Building 2610 for HDR Engineering, Inc., of Boise, Idaho. Building 2610 is located at 480 E-Street on the Mountain Home Air Force Base (MHAFB) near Mountain Home, Idaho. Mr. Zach Hall, PE, PMP of HDR Engineering, Project Manager, authorized the survey. The survey was conducted to identify asbestos containing building materials (ACBM) and lead (Pb) based paints, prior to disturbance for remodeling or demolition purposes. This asbestos and lead survey meets EPA, DEQ and OSHA regulatory requirements. Mr. Hall provided IHR with a copy of the floor plan of the building. Mr. Ed O’Reilly, represented MHAFB and Mr. Larry Rodgers, CES/CEOHV provided IHR with access to the building and previous sampling data.
BACKGROUND
The structure is primarily one-story with approximately 49,000 square feet of building space with various elevated storage and mezzanines. The original portion of the building was built in the 1970’s, with additions to the east and west ends of the original building in the 1980’s. The building exterior is a concrete “Tip up” construction design with an exposed aggregate architectural finish. The interior walls are wood and metal framed covered with drywall, and the floors are concrete on the ground floor and wood on the mezzanine.
The roof is relatively flat and has approximately 1” of gravel ballast which was recently replaced. The roof is a “Malarkey” built-up roof system, consisting of gravel ballast over 4-ply, hot mopped membranes, over 4” rigid insulation, over ¾” perlite. All areas of the building were inspected except the Post Office where because of security access was denied (see figure 1).
ASBESTOS SAMPLING
AHERA Building Inspectors, Jeff Brown, and Steve Mabe, met with Mr. Larry Rodgers (MHAFB Environmental Operations) to review existing asbestos sampling data for building 2610. After reviewing the existing data, 42 additional bulk samples of suspect asbestos containing building material (ACBM) were collected. See the attached figures for floor plans, sampling locations and material locations.
ACM, under current regulation is defined as material with an asbestos content greater than 1% by volume. Any sample analyzed by “polarized light microscopy” (PLM) method as containing a trace to less than 10% asbestos must be reanalyzed by “point count method” or may be assumed to be ACM. All samples were analyzed by International Asbestos Testing Laboratories (IATL), of Mount Laurel, New Jersey. IATL is an AIHA accredited laboratory and participant in the NVLAP/NIST program.
POINT COUNTING OF COMPOSITE ANALYSIS (ASBESTOS)
One roof flashing bulk sample was analyzed by PLM as containing greater than 1% asbestos. IHR recommended that sample FL-01-B be analyzed by “Point Counting Analysis” to meet EPA and OSHA requirements. For laboratory results of the sampled materials see Table I of this report. The result of the point counting was:
Sample ID Layer/Description
Point Counting Results
FL-01-B
Flashing around roof penetrations
PC-3.1%, Chrysotile
The flashing material around the roof penetrations will need to be removed prior to and if disturbed during renovation or demolition. The point counting of analysis of greater than (>) 1.00% is the EPA and OSHA threshold of a regulated amount. Point counting of analysis for materials less than (<) 1% is not a regulated asbestos containing material. The materials <1% may remain in the structure during demolition and may be disposed of as construction debris. IHR recommends that the materials >1% be removed from the structure prior to demolition.
ASBESTOS CONTAINING MATERIALS
CONCLUSION/RECOMMENDATIONS (ACM)
The following identifies the material, location, quantity and condition of all materials identified as containing asbestos and remaining in the structure.
Samples FL-01-A, B & C consists of approximately 100 L.F., of roof flashing that is located around each roof penetration on all three roofs. One of the samples contained greater than 3.0% Chrysotile in the flashing. The material was rated as being in good condition with no visual damage. IHR recommends the material be removed by qualified personnel and disposed of as asbestos containing waste material prior to demolition of the structure.
Certified and trained professional should remove the asbestos containing materials and properly dispose of them in a landfill that accepts such materials. Prior to any removal and/or demolition activities a notification form must be completed and mailed or hand delivered to the local DEQ office in Boise. Asbestos abatement companies are accustom to these forms and can help complete and understand the requirements.
TABLE I
Sample Number Description
Percent/Asbestos
VFT-01-A
12” Vinyl Floor Tile & Mastic in Hallways and offices.
a. tan floor tile
ND
b. tan mastic
VFT-01-B
VFT-01-C
VFT-02-A
b. yellow mastic
VFT-02-B
12” Vinyl Floor Tile & Mastic First Floor
VFT-02-C
12” Vinyl Floor Tile & Mastic First Floor
CT-01-A
2x4 Suspended Ceiling Tile with holes-First Floor
a. tan ceiling tile
CT-01-B
2x4 Suspended Ceiling Tile with holes-First Floor
CT-01-C
2x4 Suspended Ceiling Tile with holes -First Floor
CT-02-A
2x4 Suspended Ceiling Tile with fissures -First Floor
CT-02-B
CT-02-C
CT-03-A
2x4 Suspended Ceiling Tile First Floor
CT-03-B
CT-03-C
SV-01-A
Blue Linoleum & Mastic – east entrance
a. blue vinyl sheet flooring
SV-01-B
SV-01-C
SV-02-A
Grey Linoleum & Mastic – Old meat area
a. grey vinyl sheet flooring
b. off-white mastic
SV-02-B
SV-02-C
JF-01-A
Exterior Wall Joint Filler-New East Addition
a. white cementitious
b. tan foam
JF-01-B
JF-01-C
JF-02-A
Exterior Wall Joint Filler – Original Bld.
a. off-white, non-fibrous
JF-02-B
JF-02-C
DW-01-A
Textured Drywall & Mud Through Out Bldg.- New Additions
a. off-white sheetrock
DW-01-B
DW-01-C
b. white joint compound
I-01-A
Black Insulation Covering HVAC Lines in Mech. Rm.
a. black tar
I-01-B
I-01-C
EB-01-A
Hard Fitting/elbow in old grocery area
a. tan insulation
EB-01-B
EB-01-C
FL-01-A
Roof Flashing
a. black roof material
FL-01-B
3.1 (PC)
FL-01-C
RF-01-A
Roofing
a. black/tan roof material
RF-01-B
RF-01-C
(Bold) indicates regulated (>1%) asbestos containing materials
ND = None Detected
PC = Indicates stratified point count method performed
PREVIOUS ASBESTOS SAMPLING REPORT
IHR relied on previous asbestos building inspections and removal documentation that was provided by MHAFB. Two asbestos inspections were completed on building 2610 that were focused on remodeling inside the building. Northern Industrial Hygiene, Inc. of Burien, WA completed an asbestos survey that only included sampling for the remodeling of the 366th SVS/CPU room which is located to the east of the current post office location (see figure & appendix). No asbestos was identified in the wallboard (sheetrock), tan pebbled vinyl, carpet mastics, ceramic tile mastics, or drop-in ceiling panels.
In 1991, HAZTOX of Meridian, Idaho collected bulk samples of green floor tile for the new bakery area project. The green tile was 3-5% Chrysotile, while the mastic was 5-10% Chrysotile. IHR investigated the purported area of the new bakery area and was unable to locate either the green tile or black mastic. This area may have been abated at some time in the past, however, no documents were provided to IHR to substantiate this.
MHAFB also provided an EPA notification of demolition and renovation for the boiler rooms of building 2610. According to the notification, Associated Insulation, Inc. of Sunset, Utah removed 42 linear feet of asbestos piping from the boiler room in July of 2001. All piping in the boiler rooms were fiberglass.
LEAD BASE PAINT SAMPLING
Mr. Brown and Mr. Mabe, collected six (6) paint chip samples that were analyzed for lead (Pb) content. Sample locations, material descriptions and quantities are documented in the attached tables and figures.
The Housing and Urban Development (HUD) and Bureau of Indian Affairs (BIA) have established regulations for lead based paint (LBP). The disturbance of lead (Pb) containing paint is governed by the Occupational Safety and Health Association (OSHA). Regulated lead (Pb) paint is defined as paint containing > 5,000 parts per million (ppm) or 0.5% lead.
All lead (Pb) containing waste or structural building members to be disposed of must be submitted for Toxic Characterization Leachate Procedure (TCLP) analysis prior to disposal. Any material analyzed as containing > 5 milligrams per liter of leachate must be disposed of as hazardous waste at a proper landfill. All bulk paint chip samples were analyzed by analyzed by IATL of Mt. Laurel, New Jersey and this lab is accredited for this procedure. See the attached figures for general arrangement of the building and sample locations.
LEAD BASE PAINT (LBP)
CONCLUSION/RECOMMENDATIONS (LBP PAINT CHIP)
Two of the six paint chips were analyzed as containing greater than 0.5% lead. The two positive paint chip samples were collected in the Mobility Command Area located on the west end of the building. Pb-04 was collected from the yellow paint on the floor of the mobility area. IHR also noticed that this same yellow paint was located on “push carts” that were inside the mobility area.
Pb-05 was collected from the white paint and red primer on the interior wide-flange steel, vertical beams inside the mobility area. The exterior coating is white and has a red primer as a base. If MHAFB elects to remove the vertical support columns in the mobility area, they can unbolt the columns from the floor and ceiling, and save or store the columns without having to abate them. However, if welding, sanding, or grinding will be involved during the demolition or renovation, then lead abatement would be necessary.
TABLE II
LEAD PAINT CHIP SAMPLE RESULTS
Percent/Lead Paint
Pb-01
Interior Hand Rail – Dark Brown
0.0097
Pb-02
Door Frame – Light Brown
0.018
Pb-03
Mobility Roof Ladder – Black
0.015
Pb-04
Yellow Floor Paint
0.79***
Pb-05
Support Columns - White
8.0
Pb-06
Mechanical Room Interior Wall - White
0.012
*** Matrix/substrate interference possible.
DRAWINGS
F:\2008\IHR 2008\3836 HDR MHAFB Bldg. 2610\Asbestos and Lead Survey.doc
_1264320854.unknown
Presented To:
Mr. Zach Hall, PE, PMP
HDR Engineering, Inc.
412 E. Parkcenter Blvd., Suite 100
Boise, ID 83706
February, 2008
ASBESTOS AND LEAD SURVEY
CONSOLIDATED SERVICE CENTER FACILITY
BUILDING 2610
480 E-Street
MOUNTAIN HOME AFB, IDAHO
Presented By:
Industrial Hygiene Resources
206 Murray Street Boise, ID 83714 (208) 323-8287
Harry Beaulieu, PhD, CIH, CSP
Laboratory Reports
File details come from the government source that posted it. Updated .