Approved by:
Approved Signatory Renee Luna
Report for:
Mr. Jeffrey Schone, CEM; MBA Luke AFB
56 CES/CEAN
13970 Gillespie Drive Luke AFB, AZ 85309
Regarding: Project: Bldg 938 Restrooms; Saber Restroom Remodel
EML ID: 1357525
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM: 04-30-2015
Service SOPs: Asbestos PLM (EPA Methods 600/R-93/116 & 600/M4-82-020, SOP EM-AS-S-1267)
EMLab ID: 1357525, Page 1 of 2Aerotech Laboratories, Inc
EMLab P&K 1501 West Knudsen Drive, Phoenix, AZ 85027
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Luke AFB C/O: Mr. Jeffrey Schone, CEM; MBA Re: Bldg 938 Restrooms; Saber Restroom Remodel
Date of Receipt: 04-27-2015 Date of Report: 04-30-2015
ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116
Total Samples Submitted: 4 Total Samples Analyzed: 4
Total Samples with Layer Asbestos Content > 1%: 1
Location: 1, 510 Wall Tile/Grout/Mastic Lab ID-Version‡: 6223751-1
Sample Layers Asbestos Content Light Gray Ceramic Tile ND
Gray Thinset ND White Ceramic Tile ND
Sample Composite Homogeneity: Poor
Location: 2, 511 Floor Tile/Grout/Mastic Lab ID-Version‡: 6223752-1
Sample Layers Asbestos Content White Mastic ND Gray Thinset ND Brown Grout ND
Brown Ceramic Tile ND Sample Composite Homogeneity: Poor
Location: 3, 512 Floor Tile/Mastic Lab ID-Version‡: 6223753-1
Sample Layers Asbestos Content Yellow Mastic ND
Light Brown Floor Tile ND Composite Non-Asbestos Content: < 1% Cellulose Sample Composite Homogeneity: Moderate
Location: 4, 513 Transite Pipe Lab ID-Version‡: 6223754-1
Sample Layers Asbestos Content Gray Transite 5% Chrysotile
5% Crocidolite Sample Composite Homogeneity: Good
EMLab ID: 1357525, Page 2 of 2Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
File details come from the government source that posted it. Updated .