Project-1357525_Bldg_938_Restrooms.pdf

PDF 157 KB Posted

Attached to
Simplified Acquisition of Base Engineering Requirements (SABER) Federal contract opportunity
Solicitation number
FA4887-15-R-0001
Issued by
Department of the Air Force Air Education and Training Command

About this file

RFI- Drawing 6 requested

View the file

Other files for this federal contract opportunity

Other files attached to Simplified Acquisition of Base Engineering Requirements (SABER), newest first.
File Type Posted
Questions_3.docx DOCX document
Questions_2.docx DOCX document
0001_Ammendment.pdf PDF
B938-Rstrm_plumbing.pdf PDF
RFIs_Q A's.docx DOCX document
B938-One-Line_Plumbing.pdf PDF
B938_elect_panel_location.pdf PDF
B938-RstrmFlrpln.pdf PDF
B938-bldg_floor_plan.pdf PDF
B938-restrms_dimensions.pdf PDF
Attachment_12_-_Hazardous_Material_Questionaire.doc DOC document
Attachment_22_-_Bonding_Information_Request.docx DOCX document
Attachment_13_-_Contractors_Environmental_Reporting_Entry_Form.doc DOC document
Attachment_14_-_Construction_Cost_Estimate_Breakdown.xlsx XLSX spreadsheet
Attachment_18_-_DoD_Unified_Facilities_Criteria_(link).docx DOCX document
Attachment_20_-_Client_Authorization_Letter.doc DOC document
Attachment_2-_AZ150032_AZ32_WDOL_Maricopa.doc DOC document
Attachment_21_-_Financial_Information_Request.docx DOCX document
Attachment_10_-_AF_Form_3065_Progress_Report.pdf PDF
Attachment_8_-_AF_Form_66_Schedule_of_Material_Submittals.doc DOC document
Attachment_6_-_Luke_AFB_Design_and_Construction_Standards.doc DOC document
Attachment_7_-_Engineering_Technical_Letter_(ETL_02-12).pdf PDF
Attachment_4_-_Luke_AFB_Landscape_Design_and_Maintenance_Standards.pdf PDF
Attachment_23_-_Base_Access_Instructions.pdf PDF
Attachment_3-_AZ150031_AZ31_WDOL_Coconino.pdf PDF
Attachment_26-_Sample_Project_SOW.docx DOCX document
Attachment_5_-_Architectural_Design_Compatibility_Guide.PDF PDF
Attachment_11_-_AF_Form_3000_Material_Approval_Submittal.pdf PDF
Attachment_16_-_DD_1354_Transfer_and_Acceptance_of_DoD_Real_Property.pdf PDF
Attachment_17_-_USACE_Safety_and_Health_Requirements.pdf PDF
Solicitation_FA4887-15-R-0001.doc DOC document
Attachment_15_-_Luke_AFB_Master_Specifications.dot DOT file
Attachment_24-_Resume_Template.dot DOT file
Attachment_9_-_AF_Form_3064_Progress_Schedule.xlsx XLSX spreadsheet
Attachment_19_-_AFI_33-118_Radio_Communications.pdf PDF
Show all 35

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Approved by:

Approved Signatory Renee Luna

Report for:

Mr. Jeffrey Schone, CEM; MBA Luke AFB

56 CES/CEAN

13970 Gillespie Drive Luke AFB, AZ 85309

Regarding: Project: Bldg 938 Restrooms; Saber Restroom Remodel

EML ID: 1357525

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 04-30-2015

Service SOPs: Asbestos PLM (EPA Methods 600/R-93/116 & 600/M4-82-020, SOP EM-AS-S-1267)

EMLab ID: 1357525, Page 1 of 2Aerotech Laboratories, Inc

EMLab P&K 1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Luke AFB C/O: Mr. Jeffrey Schone, CEM; MBA Re: Bldg 938 Restrooms; Saber Restroom Remodel

Date of Receipt: 04-27-2015 Date of Report: 04-30-2015

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Total Samples Submitted: 4 Total Samples Analyzed: 4

Total Samples with Layer Asbestos Content > 1%: 1

Location: 1, 510 Wall Tile/Grout/Mastic Lab ID-Version‡: 6223751-1

Sample Layers Asbestos Content Light Gray Ceramic Tile ND

Gray Thinset ND White Ceramic Tile ND

Sample Composite Homogeneity: Poor

Location: 2, 511 Floor Tile/Grout/Mastic Lab ID-Version‡: 6223752-1

Sample Layers Asbestos Content White Mastic ND Gray Thinset ND Brown Grout ND

Brown Ceramic Tile ND Sample Composite Homogeneity: Poor

Location: 3, 512 Floor Tile/Mastic Lab ID-Version‡: 6223753-1

Sample Layers Asbestos Content Yellow Mastic ND

Light Brown Floor Tile ND Composite Non-Asbestos Content: < 1% Cellulose Sample Composite Homogeneity: Moderate

Location: 4, 513 Transite Pipe Lab ID-Version‡: 6223754-1

Sample Layers Asbestos Content Gray Transite 5% Chrysotile

5% Crocidolite Sample Composite Homogeneity: Good

EMLab ID: 1357525, Page 2 of 2Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

File details come from the government source that posted it. Updated .