5. MULTI_LOCATION VINDICATOR QUESTION AND ANSWERS.pdf

PDF 206 KB Posted

Attached to
MULTI-LOCATION VINDICATOR SYSTEMS Federal contract opportunity
Solicitation number
FA487724QA389
Issued by
Department of the Air Force Air Combat Command

About this file

This document contains Questions and Answers related to a Request for Quote (RFQ) for a Multi-Location Vindicator Security Systems procurement at Davis-Monthan Air Force Base.

The RFQ includes three separate CLINs for Vindicator security system upgrades at three locations: 355th SFS Door Badging System, 12 AF Alarm System/IDS, and 55 RQS ACS Vault Alarm System/IDS. Key details include requirements for compatibility with the Honeywell Vindicator Badge Manager 3 and Windows 10, no need for photo ID capabilities on badges, and the use of the base NIPRnet for networking. The procurement is being issued as a total small business set-aside under NAICS code 541519 with a $34 Million / 150 employee size standard.

View the file

Other files for this federal contract opportunity

Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFQ# FA487724QA389

MULTI-LOCATION VINDICATOR SYSTEM

QUESTIONS AND ANSWERS

Received: September 11, 2024

CLIN 0001 PWS 355th SFS Door Badging

Q1) RE: Paragraph 1.2.1.2 Equipment Removal. In Room 114, will the scope include removing the existing Schneider control enclosure to allow wall space for the new Vindicator controls enclosures?

ANSWER: Yes, the Schneider control enclosure must be removed prior to the installation of the new equipment

CLIN 0002 PWS 12 IDS

Q1) Paragraph 1.0 Secure rooms 131, 139. Do these systems need to meet IDS requirements for open collateral protection levels?

ANSWER: The rooms already meet IDS requirements

Q2) Paragraph 1.0 Honeywell Badge Manger. Will card printing w/ photo id capabilities need to be a requirement of the system?

ANSWER: Photo ID capabilities will not be required

Q3) Paragraph 5, sub a. will 2 strands of fiber patched from building 12 to building 1358 be provided by the Government?

ANSWER: Fiber should already be existing. 355 COMM Infostructure will need to verify/confirm is fiber exists

CLIN 0003 PWS 55 RSQ IDS

Q1) RE: Paragraph 1.0.1 states that database will be controlled by vindicators PC Smart pack software. Paragraph

1.1.6 states that a Vindicator Badge Manger will be required.

Could we get clarification on which database management system is required?

ANSWER: The Vindicator Badge Manager 3 with built in VBM software client is required, which will route to the Vindicator Access Control System that allows authority levels, personnel group, and location rules that ties to the door control board. The door control board ties to the door strike, request exit, and card reader.

Vindicator IDS must annunciate alarms to BDOC from the Vindicator Access Control System to include card duress, AC and DC power fails.

Q2) Will badge Printing w/ photo ID capabilities be a requirement of the system?

ANSWER: Photo ID capabilities are not a requirement for the badges and are not being requested by the 55

RQS.

Q3) Will 2 strands of fiber patched from Bldg. 1610 to Bldg. 1358 be provided by the Government?

Or will these systems be networked on the Base NIPRNet?

ANSWER: The system will require utilization of the base NIPRnet.