10 Audit.pdf
PDF 66 KB Posted
- Attached to
- Multi-Facility LED Install Federal contract opportunity
- Solicitation number
- FA487720Q0041
About this file
This document contains information regarding a forthcoming federal contract solicitation for LED lighting installation services at Davis-Monthan Air Force Base in Tucson, Arizona. The solicitation will be issued on or around October 15, 2019 for LED lighting installation across multiple facilities, with requirements varying by facility. The project value is estimated between $1-5 million. The North American Industry Classification System code is 238210 and it is set aside for small businesses with a size standard of $15 million. The contract will be awarded using lowest price technically acceptable procedures. The statement of work will include bringing all facility systems up to current codes. Interested parties must be registered in the System for Award Management and show evidence of bonding capacity up to the project maximum. The performance period is yet to be determined. The primary point of contact is 1Lt Nathan Mueller and the alternate is Jeremy Dedmon.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 2 Section L 13 Dec 19.pdf | ||
| 13 Audit 2.pdf | ||
| 12 Acceptance Period MFR.pdf | ||
| Solicitation - FA487720R00030003.pdf | ||
| 11 RFIs 12 Dec 19.xlsx | XLSX spreadsheet | |
| Solicitation - FA487720R00030002.pdf | ||
| 5 Specification LED Fixture Replacment 6 Dec 19.pdf | ||
| 8 AF Form 3052 FBNV18008 10 Dec 19.xlsx | XLSX spreadsheet | |
| 9 Contractor Environmental Guide (31 May 2018).pdf | ||
| Solicitation - FA487720R00030001.pdf | ||
| 3 Section M 20 Nov 19.pdf | ||
| 2 Section L 20 Nov 19.pdf | ||
| 4 Davis-Bacon Act WD AZ20190032.pdf | ||
| 2 Section L.pdf | ||
| 8 AF Form 3052 FBNV18008.xlsx | XLSX spreadsheet | |
| Solicitation - FA487720R0003.pdf | ||
| 5 Specification LED Fixture Replacment 2 Jul 19.pdf | ||
| 6 List of Existing Fixtures.xls | XLS spreadsheet | |
| 3 Section M.pdf | ||
| 1 - Template of Contractor EAL.xls | XLS spreadsheet | |
| 7 Past Performance Questionnaire.docx | DOCX document |
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DMAFB Lighting ECO Evaluation Counts To Be Verified
Counts MUST BE VERIFIED
Totals: 9522 25446
Bldg
Count
Building Room
Description
Existing
Lamp
Wattage
Existing
Fixture
Type
Existing
Lamp Type
Quantity of
Fixtures
Lamps per
Fixture
Total Lamps Annual
Op Hrs
L‐01 12 Office 32 flo F32T8 406 3 1218 2250
L‐01 12 Office 32 flo F32T8 100 2 200 2250
L‐01 12 Office 32 flo F32T8 20 1 20 2250
L‐02 70 Office 32 flo F32T8 188 4 752 2750
L‐02 70 Office 32 flo F32T8 28 3 84 2750
L‐02 70 Office 32 flo F32T8 36 2 72 2750
L‐03 72 Office 32 flo F32T8 38 4 152 2250
L‐03 72 Office 32 flo F32T8 168 3 504 2250
L‐03 72 Office 32 flo F32T8 100 2 200 2250
L‐04 74 Office 32 flo F32T8 221 3 663 3744
L‐04 74 Office 32 flo F32T8 32 2 64 3744
L‐04 74 Office 32 flo F32T8 21 2 42 3744
L‐05 75 Office 32 flo F32T8 204 3 612 3000
L‐05 75 Office 32 flo F32T8 23 2 46 3000
L‐05 75 Office 32 flo F32T8 8 1 8 3000
L‐06 78 Office 32 flo F32T8 12 3 36 8736
L‐06 78 Office 32 flo F32T8 42 2 84 8736
L‐06 78 Office 32 flo F32T8 42 2 84 8736
L‐06 78 Office 32 flo F32T8 19 2 38 8736
L‐07 130 0 32 FLO T8 148 3 444 3120
L‐07 130 0 32 FLO T8 11 2 22 3120
L‐08 131 0 32 FLO T8 151 3 453 4680
L‐08 131 0 32 FLO T8 16 2 32 4680
L‐09 136 0 32 FLO T8 216 2 432 2600
L‐11 253 Office 32 flo F32T8 42 4 168 2250
L‐11 253 Office 32 flo F32T8 42 4 168 2250
L‐11 253 Office 32 flo F32T8 42 4 168 2250
L‐11 253 Office 32 flo F32T8 42 4 168 2250
L‐11 253 Office 32 flo F32T8 42 4 168 2250
L‐11 253 Office 32 flo F32T8 23 4 92 2250
L‐11 253 Office 32 flo F32T8 42 3 126 2250
L‐11 253 Office 32 flo F32T8 42 3 126 2250
L‐11 253 Office 32 flo F32T8 18 3 54 2250
L‐11 253 Office 32 flo F32T8 33 2 66 2250
L‐12 254 Office 32 flo F32T8 42 4 168 2250
L‐12 254 Office 32 flo F32T8 42 4 168 2250
L‐12 254 Office 32 flo F32T8 42 4 168 2250
L‐12 254 Office 32 flo F32T8 42 4 168 2250
L‐12 254 Office 32 flo F32T8 42 4 168 2250
L‐12 254 Office 32 flo F32T8 42 3 126 2250
L‐12 254 Office 32 flo F32T8 42 3 126 2250
L‐12 254 Office 32 flo F32T8 42 3 126 2250
L‐12 254 Office 32 flo F32T8 31 3 93 2250
Bldg
Count
Building Room
Description
Existing
Lamp
Wattage
Existing
Fixture
Type
Existing
Lamp Type
Quantity of
Fixtures
Lamps per
Fixture
Total Lamps Annual
Op Hrs
L‐12 254 Office 32 flo F32T8 4 2 8 2250
L‐14 1027 Office 32 flo F32T8 1 4 4 2250
L‐14 1027 Office 32 flo F32T8 42 3 126 2250
L‐14 1027 Office 32 flo F32T8 42 2 84 2250
L‐14 1027 Office 32 flo F32T8 1 1 1 2250
L‐14 1027 Office 32 flo F32T8 41 3 123 2250
L‐14 1027 Office 32 flo F32T8 4 2 8 2250
L‐14 1027 Office 32 flo F32T8 36 1 36 2250
L‐14 1027 Office 32 flo F32T8 1 3 3 2250
L‐15 1358 Office 32 flo F32T8 2 4 8 2250
L‐15 1358 Office 32 flo F32T8 42 3 126 2250
L‐15 1358 Office 32 flo F32T8 42 2 84 2250
L‐15 1358 Office 32 flo F32T8 42 1 42 2250
L‐15 1358 Office 32 flo F32T8 42 3 126 2250
L‐15 1358 Office 32 flo F32T8 8 2 16 2250
L‐15 1358 Office 32 flo F32T8 36 1 36 2250
L‐15 1358 Office 32 flo F32T8 6 3 18 2250
L‐16 1440 Office 32 flo F32T8 42 4 168 2250
L‐16 1440 Office 32 flo F32T8 42 4 168 2250
L‐16 1440 Office 32 flo F32T8 8 4 32 2250
L‐16 1440 Office 32 flo F32T8 26 2 52 2250
L‐16 1440 Office 32 flo F32T8 1 4 4 2250
L‐16 1440 Office 32 flo F32T8 1 4 4 2250
L‐16 1440 Office 32 flo F32T8 1 4 4 2250
L‐16 1440 Office 32 flo F32T8 1 4 4 2250
L‐17 1540 Office 32 flo F32T8 11 6 66 2500
L‐17 1540 Office 32 flo F32T8 42 4 168 2500
L‐17 1540 Office 32 flo F32T8 42 3 126 2500
L‐17 1540 Office 32 flo F32T8 42 3 126 2500
L‐17 1540 Office 32 flo F32T8 7 4 28 2500
L‐17 1540 Office 32 flo F32T8 42 3 126 2500
L‐17 1540 Office 32 flo F32T8 21 3 63 2500
L‐17 1540 Office 32 flo F32T8 42 2 84 2500
L‐17 1540 Office 32 flo F32T8 42 2 84 2500
L‐17 1540 Office 32 flo F32T8 42 2 84 2500
L‐17 1540 Office 32 flo F32T8 42 1 42 2500
L‐17 1540 Office 32 flo F32T8 11 1 11 2500
L‐18 1550 Office 32 flo F32T8 29 4 116 2250
L‐18 1550 Office 32 flo F32T8 42 4 168 2250
L‐18 1550 Office 32 flo F32T8 42 3 126 2250
L‐18 1550 Office 32 flo F32T8 5 3 15 2250
L‐18 1550 Office 32 flo F32T8 42 2 84 2250
L‐18 1550 Office 32 flo F32T8 13 2 26 2250
L‐19 1610 Office 32 flo F32T8 2 2 4 8736
L‐19 1610 Office 32 flo F32T8 1 2 2 8736
L‐19 1610 Office 32 flo F32T8 1 2 2 8736
L‐19 1610 Office 32 flo F32T8 1 2 2 8736
Building Room
Description
Existing
Lamp
Wattage
Existing
Fixture
Type
Existing
Lamp Type
Quantity of
Fixtures
Lamps per
Fixture
Total Lamps Annual
Op Hrs
L‐19 1610 Office 32 flo F32T8 1 2 2 8736
L‐19 1610 Office 32 flo F32T8 1 2 2 8736
L‐19 1610 Office 32 flo F32T8 1 2 2 8736
L‐19 1610 Office 32 flo F32T8 1 2 2 8736
L‐20 2441 Office 32 flo F32T8 855 3 2565 2250
L‐21 3200 Office 32 flo F32T8 630 3 1890 2250
L‐23 3500 Office 32 flo F32T8 42 4 168 8736
L‐23 3500 Office 32 flo F32T8 31 4 124 8736
L‐23 3500 Office 32 flo F32T8 13 2 26 8736
L‐24 3501 0 32 FLO T8 104 3 312 2600
L‐24 3501 0 32 FLO T8 18 2 36 2600
L‐25 3508 0 32 FLO T8 167 2 334 3640
L‐25 3508 0 32 FLO T8 48 1 48 3640
L‐26 3509 0 32 FLO T8 203 2 406 3640
L‐27 3610 0 32 FLO T8 23 3 69 3640
L‐27 3610 0 32 FLO T8 447 2 894 3640
L‐28 3750 0 32 FLO T8 2 3 6 3640
L‐28 3750 0 32 FLO T8 127 2 254 3640
L‐29 4065 Office 32 flo F32T8 28 2 56 8736
L‐30 4211 0 32 FLO T8 26 3 78 3640
L‐30 4211 0 32 FLO T8 79 2 158 3640
L‐31 4224 0 32 FLO T8 167 2 334 3640
L‐31 4224 0 32 FLO T8 48 1 48 3640
L‐32 4320 0 32 FLO T8 116 3 348 2860
L‐32 4320 0 32 FLO T8 55 2 110 2860
L‐33 4413 0 32 FLO T8 308 3 924 3120
L‐33 4413 0 32 FLO T8 196 2 392 3120
L‐34 4430 32 0 0 16 4 64 3120
L‐34 4430 32 0 0 119 2 238 3120
L‐35 4810 0 32 FLO T8 10 4 40 2860
L‐35 4810 0 32 FLO T8 92 2 184 2860
L‐35 4810 0 32 FLO T8 5 1 5 2860
L‐37 4836 0 32 FLO T8 41 2 82 2860
L‐37 4836 0 32 FLO T8 8 1 8 2860
L‐38 4859 0 32 FLO T8 28 4 112 2860
L‐38 4859 0 32 FLO T8 12 3 36 2860
L‐38 4859 0 32 FLO T8 619 2 1238 2860
L‐39 5101 Office 32 flo F32T8 13 2 26 8736
L‐40 5129 0 32 FLO T8 55 2 110 2600
L‐41 5309 0 32 FLO T8 258 2 516 2600
L‐42 7401 Office 32 flo F32T8 42 4 168 2000
L‐42 7401 Office 32 flo F32T8 1 3 3 2000
L‐42 7401 Office 32 flo F32T8 42 2 84 2000
L‐42 7401 Office 32 flo F32T8 1 1 1 2000
L‐42 7401 Office 32 flo F32T8 1 3 3 2000
L‐42 7401 Office 32 flo F32T8 3 2 6 2000
L‐42 7401 Office 32 flo F32T8 1 1 1 2000
Building Room
Description
Existing
Lamp
Wattage
Existing
Fixture
Type
Existing
Lamp Type
Quantity of
Fixtures
Lamps per
Fixture
Total Lamps Annual
Op Hrs
L‐42 7401 Office 32 flo F32T8 1 3 3 2000
L‐43 7408 0 32 FLO T8 77 3 231 2600
L‐43 7408 0 32 FLO T8 14 2 28 2600
L‐44 7431 Office 32 flo F32T8 2 4 8 2250
L‐44 7431 Office 32 flo F32T8 29 3 87 2250
L‐44 7431 Office 32 flo F32T8 4 2 8 2250
L‐45 7439 Office 32 flo F32T8 42 4 168 2250
L‐45 7439 Office 32 flo F32T8 1 3 3 2250
L‐45 7439 Office 32 flo F32T8 17 2 34 2250
L‐45 7439 Office 32 flo F32T8 1 1 1 2250
L‐45 7439 Office 32 flo F32T8 42 4 168 2250
L‐45 7439 Office 32 flo F32T8 42 4 168 2250
L‐45 7439 Office 32 flo F32T8 32 4 128 2250
L‐46 7440 Office 32 flo F32T8 21 4 84 2250
L‐46 7440 Office 32 flo F32T8 9 3 27 2250
L‐47 7819 Office 32 flo F32T8 9 4 36 2750
L‐47 7819 Office 32 flo F32T8 1 3 3 2750
L‐47 7819 Office 32 flo F32T8 4 2 8 2750
L‐47 7819 Office 32 flo F32T8 1 1 1 2750
L‐48 7823 Office 32 flo F32T8 6 4 24 2750