2011-7-7___Demolish_bldg_438.pdf

PDF 4 MB Posted

Attached to
Attachment 19: Past Performance Survey
Solicitation number
FA4861-13-R-A014
Issued by

About this file

Abatement report bldg 438

View the file

Other files

File Type Posted
RKMF_13-0135_as-builts.zip ZIP file
2011-7-8___Demo_bldg_433.pdf PDF
2011-7-7___Demolish_Bldg_436.pdf PDF
2011-7-7___Demolish_bldg_434.pdf PDF
Atch_5 _Bid_Schedule_RKMF_13-0135_revised_16Sep2013.docx DOCX document
Solicitation_Amendment_0002.docx DOCX document
13-R-A014_Site_Visit_Attendance_Sheet.pdf PDF
Attachment_19-_Past_Performance_Survey.docx DOCX document
FA4861-13-R-A014-P00001.pdf PDF
Atch_6 __Nellis-Creech_ID2_Handbook_2011.pdf PDF
Atch_10 _AF_Form_3064.xfdl XFDL file
Atch_2 _WD_NV130034_Hwy __Mod_34.docx DOCX document
Atch_13 _DD_Form_1354.pdf PDF
Atch_7 _ETL__02-12.pdf PDF
Atch_4 _AF_Form_3052_Cost_Estimate_Breakdown.xls XLS spreadsheet
Atch_1 _SOW_Demo_Pool_dtd_20_Aug_13.docx DOCX document
Atch_15 _ACC_Arch_ _Interior_Design_Stand.doc DOC document
Atch_09 _AF_Form_66.doc DOC document
Atch_17 __ID_Warranty.Guarantee_Items.doc DOC document
Atch_11 _AF_Form_3000.xfdl XFDL file
Atch_5 _Bid_Schedule_RKMF_13-0135.docx DOCX document
Atch_16 _AF_Form_103.xfdl XFDL file
Atch_19 _PastPerformance.pdf PDF
Atch_12 _AF_Form_3065 _ProgRpt.xls XLS spreadsheet
Atch_3 _WD_NV130004 _Bldg _Mod_05.docx DOCX document
Atch_14 _UFC_1-300-08_With_C2.pdf PDF
Atch_08 _UFC_3-580-01.docx DOCX document
FA4861-13-R-A014.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Macrotec Consulting, LLC.

9724 Mild Weather Ct. · Las Vegas, NV 89148 Phone: (702) 338-8213 · Fax: (702) 629-5677

Demolition Investigation Report Asbestos and Lead Based Paint Survey

Project Information:

Nellis Air Force Base Bldg. 438

Report Info:

Macrotec Project # 11800 July 20, 2011

Prepared For:

Vince Bowers 99th Civil Engineering Squadron – CES/CEV Nellis AFB, NV 89191

Prepared By:

Dustin McAllister - Macrotec Consulting, LLC.

Table of Contents:

Introduction Scope of Services Site Description Sample Collection Methodology Sample Analysis Methodology Sample Assessment Recommendations Inspection Limitations

Appendix A Asbestos Assessment Appendix B Lead Assessment Appendix C Asbestos Sample Location Diagram Appendix C.1 Lead Sample Location Diagram Appendix D Asbestos Laboratory Report Appendix D.1 Lead Laboratory Report

Asbestos / Lead Survey Macrotec Project # 11800 Nellis Air Force Base – Bldg. 438 Page 2

INTRODUCTION

Macrotec Consulting performed an inspection for Asbestos-Containing Building Materials and Lead Based Paint on July 7, 2011. The inspection was conducted for the project defined as: Demolition of building 438 at Nellis Air Force Base in Las Vegas, NV.

The intent of this inspection was to identify materials containing asbestos and lead based paint, within the subject site, that may be impacted during planned demolition activities. Macrotec’s inspection services were conducted at the request of Vince Bowers of the 99th Civil Engineering Squadron.

Dustin McAllister, a certified lead inspector, License No. NV-I-16781-1, and a Nevada Asbestos Abatement Consultant, License No.IM0961, and Jason McAllister, a Nevada Asbestos Abatement Consultant, License No. IM0901, conducted these services for Macrotec Consulting.

SCOPE OF SERVICES

Asbestos

Macrotec’s inspection services were conducted to identify the presence of any materials containing asbestos pursuant to the requirements of NAC 618.960 and in accordance with the inspection requirements of the EPA’s: 40 CFR Part 61 National Emission Standard for Hazardous Air Pollutants (NESHAP).

These regulations outline inspection and abatement requirements for materials containing asbestos, prior to renovation and/or demolition activities.

Lead

Macrotec collected paint chip samples to identify the presence and content level of lead for compliance with the Occupational Safety and Health Administration’s (OSHA) and the Environmental Protection Agencies (EPA) regulatory requirements pertaining to worker protection and waste disposal.

SITE DESCRIPTION

The subject site was the interior and exterior of a one-story, brick building.

Macrotec’s inspection was limited to the location within the site planned for demolition as described above.

Nellis Air Force Base – Bldg. 438 Page 3

SAMPLE COLLECTION METHODOLOGY

An initial walk through of the subject site was conducted to identify homogeneous suspect materials containing asbestos and/or lead based paint, and their respective locations. This information was then used to develop a sample collection strategy.

Samples were collected by pre-wetting sample areas with water, then cutting or scraping the sample from the substrate with an appropriate sampling tool.

Whenever possible, samples were collected from areas previously damaged or deteriorating. To avoid potential contamination due to unknown asbestos and/or lead based paint content; no building systems, components, or structures were demolished to obtain samples of potentially hidden materials containing asbestos.

Each suspect bulk sample was sealed in its own zip lock plastic container and labeled with a unique identification number. Sampling tools were individually cleaned before and after each sample was collected to avoid sample cross contamination. Decontamination was accomplished using single use, pre-moistened cloths.

Samples were recorded on Macrotec’s chain-of-custody form. This form accompanied the samples to Triangle Enivronmental Service Center, Inc.

(TESC), located in Moseley, Virginia. The National Voluntary Laboratory Accreditation Program (NVLAP) accredits TESC for analysis of bulk building material samples for asbestos. The American Industrial Hygiene Association (AIHA) accredits Schneider Laboratories Inc. in Richmond Virginia, for analysis of paint chip samples for lead.

SAMPLE ANALYSIS METHODOLOGY

Asbestos

Suspect asbestos samples were subjected to analysis by polarized light microscopy (PLM). Bulk sample analysis was conducted in accordance with the EPA’s “Test Method for the Determination of Asbestos in Bulk Building Materials, EPA/600/R-93/116, 1993.

Lead

To determine lead content, the samples were submitted for analysis. Suspect paint chip samples were subjected to analysis in accordance with the EPA’s Method SW846-7420.

Nellis Air Force Base – Bldg. 438 Page 4

SAMPLE ASSESSMENT

Asbestos

Macrotec’s inspection of the subject site found Seventeen (17) separate suspect asbestos building materials, of which a total of Twenty Five (25) samples were collected and submitted for analysis.

The sample results indicated that the suspect materials were “None Detected” for asbestos content.

Note: The roof was not sampled during this investigation. The roof appears to have been recently renovated and covered using a vinyl roofing material. There is no way to check if there are older suspect asbestos containing materials beneath the new roofing material without destroying the integrity of the new roof.

The building is currently still in use, so the roof should be tested immediately prior to demolishing the building, when it is no longer in use.

See Appendix A for a listing of the materials, material locations, samples, sample locations and results for this project.

Lead

Macrotec collected Thirty One (31) paint samples of the predominate paint colors within the subject site.

Although none of the painted surfaces were found to be lead based paint (results above 5,000 parts per million), Nellis AFB may have further regulations for the handling of materials with paint over 600 parts per million. Those results are listed in the following table, which summarizes the locations of the painted surface and laboratory result.

Painted Surface Description

Material Locations

Lab Result (Parts / Million)

Light Brown Ceramic Tile This material is on some of the walls and base in the men’s and women’s rooms.

1,250 – 1,300

See Appendix B for a listing of the painted surfaces, samples, sample locations and results for this project.

Nellis Air Force Base – Bldg. 438 Page 5

RECOMMENDATIONS

Asbestos

No asbestos containing materials were identified in this investigation. If suspect materials are found during demolition activities outside what was identified in this report, stop work immediately until further testing can be completed.

Conduct an investigation of the roof prior to demolition, but after the building is no longer in use.

Lead

US EPA OSHA regulations require the implementation of worker protection if there is a potential that paint with lead in it will be disturbed during renovation activities. In accordance with these regulations Macrotec recommends:

Hiring an EPA Licensed Lead Consultant to develop a project specification based on this investigation and any other additional findings.

Hiring an EPA Licensed Lead Abatement Contractor to stabilize and/or remove all regulated lead painted materials.

Hiring an EPA Licensed Lead Consultant to monitor the removal activities and provide final clearance inspection reports.

INSPECTION LIMITATIONS

The information contained in this report is limited to those areas and suspect materials found to be visually accessible through reasonable means.

Note: The building was occupied / in use at the time of the investigation, limiting the availability of some materials and areas.

Macrotec conducted a non-destructive survey. No demolition of building materials was conducted to determine the presence of asbestos in wall cavities, chases or other inaccessible areas. Macrotec cannot warrant that these areas do not contain asbestos in locations other than those noted in this report, however, a good faith effort was made to conduct a comprehensive survey.

• Macrotec accepts no liability for additional materials or under reporting of asbestos materials that exist below other floor coverings.

• This report is not represented as, nor is it intended to be, an asbestos abatement scope of work or project specification.

Nellis Air Force Base – Bldg. 438 Page 6

• If suspect materials are discovered during future demolition operations, cease all general work activities which could impact the discovered suspect materials, until confirmation sampling can be conducted.

Thank you for allowing Macrotec Consulting to assist you with your environmental consulting needs. Please contact me with any questions regarding this report at (702) 338-8213.

Appendix A

Appendix A - Asbestos Assessment

Macrotec Job #11800 - Bldg. 438 ; WO #18001

The following table lists each of the materials suspected to contain asbestos at the subject site. For each material the sample number, location and laboratory result are listed. If the material was found to contain asbestos, the friablity and NESHAP classification is identified.

1 Sheet Rock, Mud & Tape This material is the component of the inner walls within the building.

No Asbestos Detected

AB1 Interior - Women's Room - Adj. W door None Detected

AB2 Interior - Office - SE corner None Detected

AB3 Interior - Storage Room - Adj. door None Detected

2 Spray Texture on Walls & Ceilings This material is on the inner walls and ceillings within the building.

No Asbestos Detected

AB4 Interior - Women's Room - Center None Detected

AB5 Interior - Office - Center None Detected

AB6 Interior - Office - N wall None Detected

AB7 Interior - Men's Room - Center None Detected

AB8 Interior - Storage Room - N wall None Detected

3 Yellow Base Cove Mastic This material is on walls inside the building.

No Asbestos Detected

AB9 Interior - Office - SE corner None Detected

4 Black Wainscoting Mastic This material is on the walls in the snack bar.

No Asbestos Detected

AB10 Interior - Snack Bar - S wall None Detected

5 Black Base Cove Mastic This material is on the walls in the storage room.

No Asbestos Detected

AB11 Interior - Storage Room - Adj. door None Detected

6 Beige 12x12 Floor Tile This material is on the floor of the snack bar.

No Asbestos Detected

AB12 Interior - Snack Bar - SE corner None Detected

Asbestos Survey

Bldg. 438

Macrotec Job #11800

Macrotec Job #11800 - Bldg. 438 ; WO #18001

7 Yellow Floor Mastic This material is on the floor of the snack bar.

No Asbestos Detected

AB13 Interior - Snack Bar - SE corner None Detected

8 Gray Square Pattern Floor Tile This material is on the floor of the office.

No Asbestos Detected

AB14 Interior - Office - Center None Detected

9 Floor Mastic This material is on the floor of the office.

No Asbestos Detected

AB15 Interior - Office - Center None Detected

10 Gray Floor Fill This material is on the floor of the office.

No Asbestos Detected

AB16 Interior - Office - Center None Detected

11 White Fiberglass Covering This material is on pipes in the storage room.

No Asbestos Detected

AB17 Interior - Storage Room - NE corner None Detected

12 Stucco This material is on the upper exterior walls.

No Asbestos Detected

AB18 Exterior - E Side - Overhang None Detected

AB19 Exterior - W Side - Center None Detected

AB20 Exterior - S Side - Center None Detected

13 Brick This material is the component of the outer walls.

No Asbestos Detected

AB21 Exterior - W Side - Center None Detected

14 Mortar This material is the component of the outer walls.

No Asbestos Detected

AB22 Exterior - W Side - Center None Detected

Asbestos Survey

Bldg. 438

15 Concrete Foundation This material is the building's foundation.

No Asbestos Detected

AB23 Exterior - W Side - Center None Detected

16 Grout (Ceramic Tile) This material is in the restrooms.

No Asbestos Detected

AB24 Interior - Men's Room - NE corner None Detected

17 Caulk (Sink) This material is in the restrooms.

No Asbestos Detected

AB25 Interior - Men's Room - NW corner None Detected

Asbestos Survey

Bldg. 438

Appendix B

Appendix B - Lead Assessment

Macrotec Job #11800 - Bldg. 438 ; WO #18001

The following table lists each of the painted surfaces suspected to contain lead at the subject site. For each painted surface, the sample number, location and laboratory result are listed.

Sample

Painted Surface Description

Sample Location Description

Lab Result (Parts per Million)

L1 Exterior - W side 32Beige Brick Wall

L2 Exterior - W side 49White Brick Fascia

L3 Exterior - W side Below Reportable LimitBeige Metal Flashing

L4 Exterior - E side Below Reportable LimitBeige Metal HVAC Stand

L5 Exterior - E side 36Beige Metal HVAC Stand

L6 Exterior - E side Below Reportable LimitWhite Stucco Soffit

L7 Exterior - Ext doors Below Reportable LimitBrown Metal Door Frame

L8 Exterior - Ext doors 58Brown Metal Door

L9 Exterior - NW corner Below Reportable LimitBrown Metal Door

L10 Interior - Women's Room - N wall Below Reportable LimitWhite Brick Wall

L11 Interior - Women's Room - Center Below Reportable LimitBrown Metal Stall Door

L12 Interior - Women's Room - N wall Below Reportable LimitBrown Wood Bench

L13 Interior - Women's Room - SE door 126Brown Metal Threshold

L14 Interior - Men's Room - E wall 574White Brick Wall

L15 Interior - Men's Room - N wall Below Reportable LimitBrown Metal Stall Divider

L16 Interior - Men's Room - W wall Below Reportable LimitWhite Brick Wall

L17 Interior - Men's Room - Center 64White Sheet Rock Ceiling

L18 Interior - Men's Room - S Center Below Reportable LimitBeige Concrete Shower Floor

Lead Paint Survey

Bldg. 438

Appendix B

Sample

Painted Surface Description

Sample Location Description

Lab Result (Parts per Million)

L19 Interior - Women's Room - S wall 1,300Light Brown Ceramic Base Tile

L20 Interior - Women's Room - S wall 1,250Light Brown Ceramic Wall Tile

L21 Interior - Women's Room - SE corner 136Yellow Ceramic Wall Tile

L22 Interior - Women's Room - NW corner Below Reportable LimitBrown Ceramic Shower Floor Tile

L23 Interior - Men's Room - Adj. door Below Reportable LimitGray Ceramic Floor Tile

L24 Interior - Office - S wall 171White Sheet Rock Walls / Ceilings

L25 Interior - Office - W door 534White Metal Door Frame

L26 Interior - Office - W door Below Reportable LimitBrown Metal Door

L27 Interior - Storage - N wall 81Beige Sheet Rock Wall

L28 Interior - Storage - S wall Below Reportable LimitBeige Block Wall

L29 Interior - Snack Bar - SE corner Below Reportable LimitWhite Metal Wall

L30 Interior - Snack Bar - W window Below Reportable LimitWhite Wood Window Frame

L31 Interior - Women's Room - Adj. door Below Reportable LimitGray Concrete Floor

Lead Paint Survey

Bldg. 438

Appendix C

Asbestos & Lead Based Paint Survey

Nellis AFB, Bldg. 438

Macrotec Project # 11800

Appendix C

* Diagram Not Drawn To Scale

Sample Location Diagram

N

AB1

AB2

AB3

AB4

AB5

AB6

AB7

AB8

AB9

AB10

AB11AB12

AB13

AB14

AB15

AB16

AB17

AB18

AB19

AB20

AB21

AB22

AB25

AB24

AB23

Women’s Room

Men’s Room

Office

Snack Bar Storage

Asbestos & Lead Based Paint Survey

Nellis AFB, Bldg. 438

Macrotec Project # 11800

Appendix C

* Diagram Not Drawn To Scale

Sample Location Diagram

N

L1

L2

L3

L4

L5

L6

L7

L8

L9 L10

L11

L12

L13

L14

L15

L16

L17 L18

L19

L20

L21

L22

L25

L24

L23

L26

Women’s Room

Men’s Room

Office

Snack Bar Storage L27

L28L29

L30

L31

Appendix D

File details come from the government source that posted it. Updated .